Home
Honeywell SP5700 OptimusPDA
Contents
1. Start by adhering the film to one corner of the LCD and apply film across the LCD Avoid trapping air between the LCD and the film e The Stylus pen is stored and removed from the rear of your PDA OptimusPDA SP5700 Series Quick Start Guide O Charging the PDA Insert the handset into the cradle as shown below To avoid damage to the charging connector do not force the PDA into the cradle A spare battery can be inserted in the rear slot of both cradles and charged simultaneously 1 Slot Cradle 4 Slot Cradle Before using the PDA for the first time or when the unit has not been used for a long period of time charge the battery for at least 3 hours and then perform a Hardware reset see Software Hardware reset section Red Now Charging Status e Green Charging Completed Vehicle Cradle Trigger Handle Charging Status The charging indicator on the top of the PDA shows the current charge status The LED on the charger displays the spare battery charging status a S i jamm R A Ss E Ee ow iN K ta Press Lock Key het TESS LOCK ney wv when removing lt when removing Fa x the PDA us the PDA Cs The LED light on the Vehicle Cradle and Trigger Handle indicates power is on The current charge status is indicated by the charging indicator on the PDA OptimusPDA SP5700 Series Quick Start Guide C Software Hardware Reset Under certain circumstances a Software or Hardware res
2. et may be needed to be performed on your PDA The below tables explain how to perform a software or hardware reset Press Reset button on the rear of Press Power button and Reset Suites the PDA using the Stylus Pen ARATE button simultaneously Reset Reset Reset ii O Reset Using sharp objects may cause damage to the PDA A Only use the Stylus Pen provided to press the Reset button O PC Synchronization Press the Sync Button on the 4 slot cradle to sync PDA with PC To communicate with a host PC connect the PDA to the PC and run Microsoft ActiveSync Connection can be made via the Vehicle Cradle Trigger Handle or either of the charging cradles ActiveSync software can be downloaded from http www microsoft com for installation on your PC O Optimal Scanning Direction Iil sesesocosososocososoooooseoosososeosoooeoooseoosososooosososososocooososocooososooosooososssoosososocososooooosososooosoo Laser Imager Barcode e For Optimal scanning hold the base of the barcode just below the PDA scanning unit e Press and hold either scan button until the scan is complete OptimusPDA SP5700 Series Quick Start Guide O Troubleshooting a PDA turns off after a period of inactivity The period can be set in PDA turns itself off PDA is in Sleep Mode Settings Power tab By pressing the power button The PDA will return to the status it was before going in to sleep mode C
3. hange the battery Battery failed end of lif ren uterine yee ee If the PDA is still not active perform a Hard Reset Battery did not a charge POA weet MNSEREUINO Me Stee Insert the PDA into the Cradle again to charge properly I O Connector is not clean Clean dust or rust with dry cloth Incorrect IP input Check the static IP and set again Fail to use WiFi B Crished More than 2 PDAs are using the same static a Ask your system manager for the correct IP settings Lack of battery power WiFi communication may fail when the battery is low Tapping the Temporary system error occurred Execute Software Reset and recalibrate the Stylus in the screen buttons or Settings Stylus tab icons does not activate LCD screen does not calibrate correctly Recalibrate Stylus pen In Settings Stylus tab PDA is not inserted into Cradle correctly Insert the PDA into the Cradle again and run ActiveSync Check the cable connection status and authenticity of Cradle is not connected i i ActiveSync is not e cable working ActiveSync installed incorrectly Reinstall Active sync in the PC Connected as a Guest not the name you Remove the PDA from the Cradle and re insert set Input the PDA name again Volume setting is low Check the volume slider in Settings Speaker is not clean Remove dust in speaker A message Too many files stored on the PDA Transfer stored Data to PC or delete unused files appears stating that M Full ae oe eels ales Memory allocation is too
4. heir respective companies and are the property of their respective owners o OptimusPDA SP5700 Series Quick Start Guide O Box contents Protection Film Battery Stylus Pen Hand Strap Basic Items Optional Items O Parts of the PDA Operation Indicator LED Speaker Charging Indicator LED Touch Screen 4 Way Navigation Pad Ear Phone Jack Backlight Button Scan Button Power Button Keypad Microphone I O Connector Soft Reset Button Battery Cover Lock Key Battery Cover Digital Camera Optional Stylus Pen Hand Strap Hole Scanner Type may vary Scan Button Mini USB Port IrDA Communication Antenna OptimusPDA SP5700 Series Quick Start Guide O MiniSD Card and SIM Card Installation MiniSD Card Installation SIM Card Installation Insert MiniSD Card with label facing upwards To remove Open the battery cover and remove the paper labeled gently press the card into the socket to eject UIM SIM Card Slot Area before inserting the SIM card To install a battery slide the battery cover lock to the open position Remove the battery door and insert a new battery Replace the battery door ensuring the battery door lock is in the closed position Always ensure your PDA is switched off when changing batteries Pulling out Stylus Pen Adhering Protection Film e Gently wipe the LCD with a soft cloth before adding the protective film e
5. low Adjust Memory allocation in the System Memory Scan window is dirty or obstructed Gently clean scan window with soft cloth Target barcode was moving while scanning Rescan the barcode without the bar code moving Scanning Program was not activated Activate Run Scanner in Settings Barcode tab PDA does not Unreadable barcode Ensure the barcode is not defaced accept scan input eee ee SCAN WINGON ANG Ensure you are within proper scanning range 15cm barcode is incorrect E Niel Ensure that the barcode program recognizes the barcode type type of barcode Scan under direct sunlight Lean the barcode to 45 direction or scan the barcode back against the sunlight No sound is audible OptimusPDA SP5700 Series Quick Start Guide Patents This Honeywell product may be covered by but not limited to one or more of the following U S Patents US Patent No 5 867 688 6 389 477 6 493 747 6 507 868 6 571 294 6 772 201 6 820 050 6 976 626 7 121 468 7 337 968 7 341 191 No license right or sublicense is granted either expressly or by implication estoppel or otherwise under any Metrologic Honeywell or third party intellectual property rights whether or not such third party rights are licensed to Metrologic and or Honeywell including any third party patent listed above except for an implied license only for the normal intended use of the specific equipment circuits and devices represented by or contained in the
6. o OptimusPDA SP5700 Series Quick Start Guide OptimusPDA SP5700 Series Quick Start Guide We really work for you OptimusPDA SP5700 Series Quick Start Guide Disclaimer Metrologic Instruments Inc a wholly owned subsidiary of Honeywell International Inc Honeywell reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult Honeywell to determine whether any such changes have been made The information in this publication does not represent a commitment on the part of Honeywell Honeywell shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this manual This document contains propriety information that is protected by copyright All rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Honeywell 2007 2009 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks Metrologic and OptimusPDA are trademarks or registered trademarks of Metrologic Instruments Inc or Honeywell International Inc Microsoft and ActiveSync are registered trademarks of Microsoft Corporation Other product names mentioned in this manual may be trademarks or registered trademarks of t
7. products that are physically transferred to the user and only to the extent of those license rights and subject to any conditions covenants and restrictions therein Other worldwide patents pending Metrologic Instruments Inc 90 Coles Road Blackwood NJ 08012 4683 OptimusPDA_QS_SP5700
Download Pdf Manuals
Related Search
Related Contents
Severin BA 3253 iron Baixar manual Dear Valued MD On Crown Equipment SR 5200 Automobile User Manual User Manual - LiftingSafety 5200 Series Descargar Manual - X The Joy Factory MagConnect Edge M F2A3X Frequency to Analog Converter Module Copyright © All rights reserved.
Failed to retrieve file