1. please contact your local dealer for service 2 Hardware Description 2 1 Front Panel o n A 23 yL LK ACT 10 100 RC E 100Base FX FVT 4001 FVT 4002 FVT 4301 5 O E e T 10 100 1000 GVT 4000 1000Base 1 RJ 45 Port 3 DIP Switch 2 LED 4 Fiber SFP Connector 2 2 Rear Panel DC 9V CO Power Adapter DC 9V 0 7A The rear panel contains a power socket This power socket accepts DC9V voltage and minimum 0 7A supplied current 2 3 LED Indicators Fast Ethernet Module LED Status Meaning PWR Green Power on 100 Green 100Mbps UTP Speed OFF 10 Mbps UTP Speed Green The unit is linking with it s link partner LK ACT n E UTP Blinks The unit is transmitting or receiving packets Off No device attached Green The unit is linking with it s link partner LK ACT 7 a T aS Fiber Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full duplex mode FDX COL 7 UTP Blinks Collision of Packets occurs in the port Off Half duplex mode or no device attached Orange The fiber port is operating in full duplex mode FDX COL En 5 Fiber Blinks Collision of Packets occurs in the port Off Half duplex mode or no device attached Gigabit Ethernet Module LED Status Meaning PWR Green Power on Green 1000M
2. Switch architecture Fiber parameters Transparent packet Link Lost Forward DIP Switch LED Power Dimension IEEE802 3 10BASE T IEEE802 3u 100BASE TX 100BASE FX IEEE802 3x Flow Control and Back pressure Fiber Duplex ST SC RJ 45 Socket CAT 3 5 10 100Mbps Twisted Pair cable Auto MDI MDI X Auto Negotiation Store and Forward Fiber Core Multi Mode 62 5 125um 50 125um Single Mode 8 125um 9 125um Wavelength 1310nm Multi mode 1310nm Single mode Fiber Distance Multi Mode Fiber 2KM Single Mode Fiber 30 KM 64 to 1600 Bytes for Non VLAN Ethernet packet UTP Fiber If UTP port link down then converter will forced fiber to link down Fiber UTP If Fiber port link down the media converter will force UTP port to link down DIP Switch 1 UTP Auto Nego 100Mbps Full Duplex mode DIP Switch 2 Fiber Full Half Duplex DIP Switch 3 LLF Link Lose Forwarding Disable Enable DIP Switch 4 Switch Converter Pure converter mode Power UTP 100Mbps LK Act FDX COL Fiber LK Act FDX COL DC9V 0 7A 119mm x 85mm x 26mm EMI amp safety CE FCC Class A 11 Gigabit Ethernet Module Standard Connector Switch architecture Fiber parameters Transparent packet Link Lost Forward DIP Switch LED Power Dimension IEEE802 3 10BASE T IEEE802 3u 100BASE TX 100BASE FX IEEE 802 3ab 1000BaseT IEEE 802 3z 1000BaseSX LX standards IEEE802 3x Flow Contr
3. bps UTP Speed SPD Orange 100Mbps UTP Speed OFF 10Mbps UTP Speed Green The unit is linking with its link partner LNK ACT 7 E EN E UTP Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full duplex mode FDX COL m UTP Blinks Collision of Packets occurs in the port Off Half duplex mode or no device attached Green The unit is linking with its link partner LNK ACT Blinks The unit is transmitting or receiving packets from Fiber FX devices Off No device attached Orange The fiber port is operating in full duplex mode FDX COL s Fiber Blinks Collision of Packets occurs in the port Off Half duplex mode or no device attached 2 4 DIP switch The DIP switch is used to configure operation mode for LLF Link Lost Forwarding and operation mode for UTP Fiber port The default value of DIPswitch is OFF Fast Ethernet Module No Status Description ON UTP 100Mbps Full Duplex mode 1 OFF UTP Auto Nego ON Fiber in Half Duplex OFF Fiber in Full Duplex ON LLF Enable 3 OFF LLF Disable ON Pure converter mode OFF Switch Converter mode Gigabit Ethernet Module No Status Description ON Fiber in 1000Mbps Full Duplex I OFF Fiber Auto Negotiation ON UTP LLF Enable 2 OFF UTP LLF Disable A ON Fiber LLF Enable OFF Fiber LLF Disable Link Lost Forwarding When LLF i
4. he smart way by providing a single power supply With the Plug and play technology the converter is easy to set up and run For simple cost effective network design LevelOne converter Series is the perfect solution to bridge the complex network infrastructure 1 1 Features Fast Ethernet Module Comply with IEEE 802 3 802 3u and 802 3x standards Convert between UTP cabling and Fiber optic cabling One RJ 45 connector Auto MDI MDIX for UTP port Support 10 100 Mbps Auto negotiation for UTP port Fiber cabling connectivity up to 30Km Store and forward switching to separate two collision domains One fiber connector SC ST for 100Base FX 4DIP switches to set the operation mode Link Lost Forwarding function Gigabit Ethernet Module Comply with IEEE 802 3 802 3u and 802 3x IEEE 802 3ab 1000BaseT 802 3z 1000BaseSX LX standards Convert between UTP cabling and Fiber optic cabling One RJ 45 connector Auto MDI MDIX for UTP port Support 10 100 1000 Mbps Auto negotiation for UTP port Fiber cabling connectivity up to 70Km Store and forward switching to separate two collision domains One fiber connector SC SFP for 1000Base SX LX DIP switches to set the operation mode function Link Lost Forwarding function 1 2 Package Contents Stand alone Media Converter Power Adapter DC 9V 0 7A User Manual Compare the contents of your converter module with the checklist above If any item is damaged or missing
5. o Z 2 ONNEN JEE m ommi Copper to Fiber Stand Alone Media Converter User Manual Part No Model No Description se mra Tg 531052 FVT 4002 S MM sa wm eren ae A 531404 GVT 4000 1010010008 5 1 SFP 531402 GVT 4001 10 100 1000Base T to 10005 SC Multi mode 550m Ver 1 00 0610 Table of Contents 1 INTRODUCTION 1 Vids EEAT BES tio ee ur 1 1 2 PACKAGE 5 2 2 HARDWARE DESCRIPTION 3 2 1 FRONTPANEEL unenian o 3 2 2 REAR PANEL 4 2 3 LED INDICATORS n 5 2 4 DIP SWITCH 7 3 CABLING 9 4 SPECIFICATION 11 5 OPTIONAL SFP MODULES 13 1 Introduction LevelOne media converters are Fast Ethernet 100Base TX to 100Base FX and 1000Base T to 1000Base SX LX converters to provide the flexibility required in network integration The TX port auto sense connection speed auto negotiates half full duplex modes and auto selects MDIX media type The fiber connectors come with multimode or singlemode SC ST or SFP connector to provide necessary connection interface and distance capabilities LevelOne have designed 19 racks to organize media converters t
6. ol and Back pressure only for GVT 5001 and Giga Fiber port in Auto Nego mode Fiber SC SFP RJ 45 Socket CAT 5 10 100 1000Mbps or pure 1000Mbps Twisted Pair cable Auto MDI MDI X Auto Negotiation Store and Forward Fiber Core Multi Mode 62 5 125um 50 125um Wavelength 1310nm Multi mode Fiber Distance 550M Multi Mode Fiber 64 to 1536 Bytes for Ethernet packet UTP Fiber If UTP port link down then converter will forced fiber to link down Fiber UTP If Fiber port link down the media converter will force UTP port to link down DIP Switch 1 Fiber Auto Nego 1000Mbps Full Duplex mode DIP Switch 2 UTP Fiber LLF Disable Enable DIP Switch 3 Fiber UTP Disable Enable Power UTP SPD LK ACT FDX Fiber LK Act FDX COL DC9V 0 7A 119mm x 85mm x 26mm EMI amp safety CE FCC Class A 12 5 Optional SFP Modules GVT 4000 supports 3 3V mini GBIC module Part No Model No Description 570622 GVT 0300 551071 0301 Sd aie aa 551072 GVT 0302 Mini GBIC SFP transceiver Single Mode 70km c re X 13
7. s enable allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side Therefore A link loss forward feature is provided in both UTP and Fiber side Pure Converter mode Fast Ethernet Module When pure converter mode is enabling on it operates with the minimum latency The transmission flow does not wait until entire frame is ready but instead it forwards the received data immediately after the data being received And TP port should be forced at 100M in this application When DIP Switch is in Switch Converter mode off the converter function is same as Switch Hub Note Please don t change the DIP switch setting when UTP or fiber port is transmitting or receiving data It may cause some data error 3 Cabling Fast Ethernet Module Twisted pair segment can be use unshielded twisted pair UTP or shielded twisted pair STP cabling The cable must comply with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable You can connect two devices up to a 2 kilometer 6 562 ft distance Fiber segment using single mode connector type must use 8 125 or 9 125 um single mode fiber cable You can connect two devices in the distance of 30 Kilometers in full d
8. uplex operation For half duplex operation the recommended maximum distance is 412 meters 1 352 ft Gigabit Ethernet Module Using four twisted pair Category 5 cabling for RJ 45 port connection The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable You can connect two devices up to 550m distances Fiber segment using single mode connector type must use 8 125 or 9 125 um single mode fiber cable You can connect two devices in the distance of 10 Kilometers in full duplex operation For half duplex operation the recommended maximum distance is 412 meters 1 352 ft Optical Fiber Avg Launch Avg Module Name Wavelength Power Sensitivity 100Base FX Fiber SC MM 1310 nm 18 dB 30 dB 100Base FX Fiber ST MM 1310 nm 18 dB 30 dB 100Base FX Fiber SC SM 1310 nm 6 dB 34 dB 1000Base SX Fiber SC MM 850 nm 10 dB 17 dB Avg Power Max FDX Module Name x Fiber Fiber Size um Loss Budget Distance i 62 5 125 100Base FX Fiber SC MM 12 dBm 2 Km 50 125 62 5 125 100Base FX Fiber ST 12 dBm 2 Km 50 125 100Base FX Fiber SC SM 28 dBm 30 Km MEE 62 5 125 1000Base SX Fiber SC MM 7 dBm 550 m 50 125 10 4 Specification Fast Ethernet Module Standard Connector