1. InfraStruXure for Wiring Closets and Computer Rooms 13 Basic Installation Procedures 3 Level the enclosures Leveling feet are attached under the enclosure at the corners The leveling feet can help provide a stable base if the selected floor space is uneven but cannot compensate for a badly sloped surface To level the enclosure a Fit the 14 millimeter end of the open ended wrench provided to the hex head just above the round pad on the bottom of a leveling foot Turn the wrench clockwise to extend the leveling foot until it makes firm contact with the floor b Repeat step a for each of the remaining leveling feet c Use a level to determine which feet need further adjustment to level the enclosure Adjust as necessary Install the UPS m Follow the installation procedures in the manual included with your UPS See also Use two people to install the UPS Heavy Install the UPS in the bottom of the selected rack or enclosure See Site Planning on page 10 for sample configurations If you have a Symmetra RM UPS ora Symmetra LX UPS install the power and battery modules after you install the UPS in the rack Install the Rack PDU Extender The Rack PDU Extender is used primarily with the Symmetra LX UPS and the NetShelter VX Enclosure It snaps into the base of the NetShelter VX rear channel and occupies the bottom 2U of space behind
2. Connect UPS Batteries The Smart UPS models are shipped with the batteries installed however you must make the necessary connections to energize the batteries before the UPS will operate Ensure that the battery modules in the Symmetra RM or Symmetra LX UPS are seated properly C See the manual included with your UPS for detailed safety and installation instructions See also Configure APC management devices Your InfraStruXure System can be managed through the APC Network Management Card or through the InfraStruXure System Manager If you have an InfraStruXure System Manager as part of your system connect each Network Management card to the InfraStruXure System Manager hub using CATS network cables and configure the InfraStruXure System Manager See the manual included with your InfraStruXure System Manager for quick LA configuration instructions and see the on line help on the InfraStruXure System See also Manager s interface for more information on managing the system If you do not have an InfraStruXure System Manager as part of your system configure the network settings of each Network Management card in your system K See the manual included with your Network Management Card for quick configuration 1 instructions and the supporting documentation on the CD for more detailed See also information InfraStruXure for Wiring Closets and Computer Rooms InfraStruXure Standard Warranty
3. APC warrants that all components of the InfraStruXure system will be free from defect in material and workmanship for a period of two years from the date of start up when start up has been performed by APC authorized service personnel If assembly services are included in the original purchase and are also performed by APC authorized service personnel APC offers an additional year of warranty at no additional charge In the event that the system fails to meet the forgoing warranty APC shall repair or replace at its sole discretion any such defective parts Under this warranty APC will ship all parts to your site at no cost to be available for you the next business day after APC is notified of this requirement If you choose to upgrade the system to include an on site contract APC offers modular service packages to match your needs Each point product incorporated into the system has a separate factory warranty that is applied when sold as a standalone unit When incorporated into an InfraStruXure solution the unit will be covered by the InfraStruXure warranty In cases where one warranty favors the customer over the other the stronger of the two warranties will take precedence All warranties are null and void unless installation and startup are performed by authorized APC Global Services service centers APC shall not be liable under this warranty if its testing and examination disclose that the alleged defect in the product does not e
4. Shelving Services APC offers the following service packages for InfraStruXure Systems Installation and Start Up Services Preventative Maintenance Pre Installation Consulting Battery Refresh Programs Extended Warranties Network Integration for APC Software On Site Service Remote Monitoring Service T Some services are not available in all areas 4 InfraStruXure for Wiring Closets and Computer Rooms Site Preparation Verify the shipment Ensure that all labeled pallets and boxes match your purchase order Do not unpack the pallets and boxes until you are ready to install the system Environmental requirements A Batteries can be permanently damaged if installed in a system that is not being used Store battery modules at an ambient temperature below 25 C Warning Select a site that is temperature controlled clean dry and free of conductive contaminants and that meets the following specifications Temperature 0 to 40 C Relative Humidity 0 95 non condensing Elevation above mean sea level 0 3000 m Consider the heat dissipation ratings of equipment to determine cooling requirements Additional cooling equipment may be required For heat dissipation ratings of common InfraStruXure System UPS types see the individual UPS product pages on the APC Web site www apc com InfraStruXure for Wiring Closets and Computer Rooms Site Preparation Access and ventilation requirements Consult your l
5. the rear vertical mounting rails TE Follow the procedures in the instruction sheet included with your See also Rack PDU Extender InfraStruXure for Wiring Closets and Computer Rooms Basic Installation Procedures Install Rack PDUs eA See the manual included with your Rack PDUs for detailed safety and installation instructions See also Install vertical APC Rack PDUs in the rear of a NetShelter VX Enclosure in the cable channel directly behind the rear vertical mounting rails You can install the Rack PDU in one of two ways using toolless mounting pegs provided or the mounting brackets sold separately You can mount two Rack PDUs on one side of the enclosure by using Note the toolless mounting method 1 Slide the mounting pegs into the holes located in the channel in the rear panel of the enclosure 2 Snap the Rack PDU into place by pushing it downward until it locks into position Install optional equipment in the enclosures T See the manual included with your optional InfraStruXure equipment for detailed safety and installation instructions See also InfraStruXure for Wiring Closets and Computer Rooms 15 Basic Connection Procedures Overview This section illustrates typical configurations Your configuration may vary If you have questions consult the user manual of each component visit t
6. D ROM allegato Deze handleiding staat in het Nederlands op de bijgevoegde cd Instrukcja Obslugi w jezyku polskim jest dostepna na CD O manual em Portugu s est dispon vel no CD ROM em anexo Mucrpykuun HO HCHO Ib3OBAHHIOIHAa PYCCKOM A3bIKe HIIpH Ia l Aa e TC H LHCKe CD AXZ O HABBO CD ROM PST R LT T System Components Rack NetShelter VX NetShelter VX NetShelter NetShelter Enclosure Open Frame 4 Post Open Frame 2 Post Open Frame Power Smart UPS Smart UPS RT Symmetra RM Symmetra LX 1500 VA 2200 VA 2000 VA 3000 VA 2 6 kVA 4 8 kVA 8 16 kVA 3000 VA 5000 VA 5000 VA 7500 VA 10 000 VA Power Distribution Basic Metered Switched Rack PDUs Rack PDUs Rack PDUs InfraStruXure for Wiring Closets and Computer Rooms System Components Management InfraStruXure System Environmental Environmental Manager Management System Monitoring Unit Network Environmental Building Management System Management Card Monitoring Card Integration Card NetworkAIR NetworkAIR Air Distribution Unit Air Removal Unit Rack accessories APC offers the following rack accessories for InfraStruXure Systems Keyboard drawers Stabilization plates and brackets Keyboards Shielding troughs and cable ladders Rack mounting hardware Blanking panels Rack fan systems Grounding kits Security devices Rack PDU mounting brackets
7. Infrastrup Cure POWER RACK AIR InfraStruXure for Wiring Closets and Computer Rooms Site Preparation Site Planning and Installation InfraStruXure for Wiring Closets and Computer rooms is an integrated power rack air and management architecture consisting of standard plug and play components This architecture allows for fast and easy installation and helps eliminate disorganization within an IT environment by providing a foundation for your critical IT equipment that fosters organization ease of use and control This guide summarizes how to install your InfraStruXure System For detailed installation operation and maintenance instructions see the documentation included with each component in your system Contact your APC representative or visit the APC website www apc com for a complete list of InfraStruXure System options and additional documentation Before installing or operating any InfraStruXure System components read the safety instructions and warnings included in each component s manual Arc www apece com 9L 28 e di NE T v This manual is available in English on the enclosed CD Dieses Handbuch ist in Deutsch auf der beiliegenden CD ROM verf gbar Este manual est disponible en espa ol en el CD ROM adjunto Ce manuel est disponible en frangais sur le CD ROM ci inclus Questo manuale disponibile in italiano nel C
8. Rooms 9 Site Planning The following are sample configurations you can use to plan the layout of NetShelterVX your computer room Actual number of racks supported may be less than Dimensions shown depending upon the actual load per rack The clearances shown are the minimum requirements Check your local and national codes for additional nee imm requirements 600 mm Smart UPS 1500 VA Supports up to two NetShelter VX enclosures and one UPS 914 mm 914mm Smart UPS 2200 VA or 3000 VA Supports up to three NetShelter VX enclosures and one UPS 914mm Smart UPS 5000VA or Symmetra RM 2 6 kVA Supports up to four NetShelter VX enclosures and one UPS 914mm 914mm 10 InfraStruXure for Wiring Closets and Computer Rooms Site Planning Symmetra LX 4 8 kVA Supports four NetShelter VX enclosures one UPS and one Rack PDU Extender Parallel rows Set up two short parallel rows Run a APC Cable Ladder between the rows 914mm Adjacent short rows Set up two short adjacent rows Run a APC Cable Ladder between the rows 914mm 1219mm 914mm tRack PDU Extende TRack PDU Extender One row Set up one long row InfraStruXure for Wiring Closets and Computer Rooms 11 Site Planning Symmetra LX 8 16 kVA Supports eight NetShelter VX enclosures one UPS and one Rack PDU Extender Parallel rows Set up two sh
9. Smart UPS 5000 8 IEC 320 C13 230 2 IEC 320 C19 Smart UPS RT 2000 6 IEC 320 C13 230 Smart UPS RT 3000 8 IEC 320 C13 230 2 IEC 320 C19 Smart UPS RT 5000 8 IEC 320 C13 230 2 IEC 320 C19 Smart UPS RT 7500 4 IEC 320 C13 230 4 IEC 320 C19 1 Hard wired 3 wire H N G Smart UPS RT10000 4 IEC 320 C13 230 4 IEC 320 C19 1 Hard wired 3 wire H N G 8 InfraStruXure for Wiring Closets and Computer Rooms Site Preparation Emergency Power Off EPO A licensed electrician must connect the remote emergency power off EPO device Electrical azard If required by local or national codes you must connect the EPO to disable output power in an emergency either as internally powered for use with non powered switch circuits or externally powered for use with 24 VDC powered switch circuits The EPO circuit must be a Class 2 UL and CSA standard and SELV IEC standard circuit isolated from all primary circuitry See the installation istructions included with your UPS for instructions on wiring The connection of the UPS to the EPO requires one of the following cable types Cable Description CL2 Class 2 cable for general use prap Plenum cable for use in ducts plenums and other spaces used for environmental air flow CL2R Riser cable for use in a vertical run in a shaft from floor to floor CLEX Limited use cable for use in dwellings and in raceways InfraStruXure for Wiring Closets and Computer
10. Symmetra are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions All other trademarks product names and corporate names are the property of their respective owners and are used for informational purposes only 990 1681 001 TAA 09 2004
11. he APC Web site www apc com or contact Customer Support at a number on the back cover of this manual Do not use only these diagrams to connect your equipment Read and follow the safety and connection instructions in the manual included with your UPS and Caution Power distribution equipment Smart UPS 1500VA 2200VA 3000 VA NetShelter VX Rack PDU AP9568 IEC 320 C14 Plug 16 InfraStruXure for Wiring Closets and Computer Rooms Basic Connection Procedures Symmetra RM 2 6 kVA UPS NetShelter VX Enclosure Rack PDU AP7852 NetShelter VX Enclosure Urn Dom U mim oo xr Rack PDUs AP7852 Un Ur AM Uxp E DUO EGG Rack PDU Extender InfraStruXure for Wiring Closets and Computer Rooms 17 Basic Connection Procedures Connect Rack PDUs to the UPS Route the Rack PDU power cords to the UPS through the bottom of the enclosures using the holes in the enclosures vertical posts Plug each power cord into an outlet on the UPS or Rack PDU Extender The diagram shows vertical Rack PDUs however you can use any APC Rack PDUs with plugs that match your UPS outlets or Rack PDU Extender outlets See Electrical requirements and safety on page 7 for information on the outlet type of each UPS
12. iring Closets and Computer Rooms 19 Arc www apc com APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC Knowledge Base and using e support Contact an APC Customer Support center by telephone or e mail Regional centers Direct InfraStruXure Customer Support Line 1 877 537 0607 toll free APC headquarters U S Canada 1 800 800 4272 toll free Latin America 1 401 789 5735 USA Europe Middle East Africa 353 91 702000 Ireland Japan 0 35434 2021 Australia New Zealand South Pacific area 61 2 9955 9366 Australia Local country specific centers go to www apc com support contact for contact information Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support Entire contents copyright O 2004 American Power Conversion All rights reserved Reproduction in whole or in part without permission is prohibited APC the APC logo InfraStruXure NetShelter NetworkAIR Smart UPS and
13. ocal and national building and fire codes for additional requirements 2527mm Weight considerations Ensure that the floor and sub floor can support the total weight of the system concentrated on the leveling feet of the system s enclosure If you are placing equipment on a raised floor consult the flooring manufacturer for loading requirements before installing equipment Decide what equipment will be installed in your racks and enclosures Do not exceed the maximum capacity listed in the table Rack or Enclosure Maximum Capacity NetShelter VX Enclosure 907 kg NetShelter VX Open Frame 907 kg NetShelter 4 Post Open Frame 454 kg NetShelter 2 Post Open Frame 340 kg 6 InfraStruXure for Wiring Closets and Computer Rooms Electrical requirements and safety Site Preparation Consult your UPS and power distribution manuals for detailed electrical requirements and installation instructions Electrical azard Consult your national and local codes for requirements other than those listed in the manuals included with your products The UPS contains internal batteries and may present a shock hazard even when disconnected from the branch circuit mains See the safety information in your UPS manual Electrical input Connection Voltages Product Method Connection Type Supported Symmetra RM 2 6kVA Hard wired 40 A 2 pole external 10 AWG 6 mm 230 Symme
14. ort parallel rows Run a APC Cable Ladder between the rows sem 914 mm 914 mm Adjacent short rows Set up two short adjacent rows Run a APC Cable Ladder between the rows T Rack PDU Extender fRack PDU Extender One row Set up one long row Rack PDU Extender 12 InfraStruXure for Wiring Closets and Computer Rooms Basic Installation Procedures Unpack racks and enclosures Unpack each rack and enclosure included with your shipment according to the unpacking instructions in the rack or enclosure manual Q Make sure all boxes and packaging are empty before discarding them Note Assemble racks and enclosures Orient the racks and enclosures in the planned location see Site Planning on page 10 and make any necessary adjustments to the enclosures that are needed for your location If you have enclosures as part of your system Each row should include one enclosure with side panels The other enclosures should be expansion enclosures without side panels 1 Place the enclosure with side panels at the end of the row and remove the side panel that is adjacent to an expansion enclosure Place the side panel that you removed on the expansion enclosure at the end of the TOW 2 Join adjacent enclosures See the manual included with your enclosures for See also instructions
15. tra LX 4 8kVA Hard wired 50 A 2 pole external 6AWG 16mm 230 Symmetra LX 8 16 kVA Hard wired 100 A 2 pole external 3 AWG 25 mm 230 Smart UPS 1500 Cord connected IEC 320 C14 230 Smart UPS 2200 Cord connected IEC 320 C20 Schuko CEE 7 EU1 16P or 230 British BS136A Smart UPS 3000 Cord connected IEC 320 C20 Schuko CEE 7 EU1 16P or 230 British BS136A Smart UPS 5000 Hard wired 3 wire 10 AWG 6mm 230 Smart UPS RT 2000 Cord connected IEC 320 C20 Schuko CEE 7 EU1 16P or 230 British BS136A Smart UPS RT 3000 Cord connected IEC 320 C20 Schuko CEE 7 EU1 16P or 230 British BS136A Smart UPS RT 5000 Hard wired 3 wire 10 AWG 6 mnm 230 Smart UPS RT 7500 Hard wired 50 A 2 pole 8 AWG 10 mm or 230 50 A 4 pole 8 AWG 10 mm Smart UPS RT 10000 Hard wired 63 A 2 pole 6 AWG 16 mm or 230 63 A 4 pole 6 AWG 16 mm Cord Connected PDU Cord connected IEC 320 C19 230 InfraStruXure for Wiring Closets and Computer Rooms Site Preparation Electrical output Voltages Product Connection Type Supported Symmetra RM 2 6kVA 8 IEC 320 C13 230 2 IEC 320 C19 Symmetra LX 4 8kVA 8 IEC 320 C13 230 6 IEC 320 C19 1 Hard wired 3 wire G N L1 Symmetra LX 8 16kVA 8 IEC 320 C13 230 10 IEC 320 C19 1 Hard wired 3 wire G N L1 Smart UPS 1500 4 IEC 320 C13 230 Smart UPS 2200 8 IEC 320 C13 230 1 IEC 320 C19 Smart UPS 3000 8 IEC 320 C13 230 1 IEC 320 C19
16. xist or was caused by purchaser s or any third person s misuse negligence improper installation or testing unauthorized attempts to repair or modify or any other cause beyond the range of the intended use or by accident fire lightening or other hazard There are no waranties express or implied by operation of law or otherwise of products sold serviced or furnished under this agreement or in connection herewith APC disclams all implied warranties of merchantability satisfaction and fitness for a particular purpose APC s express warranties will not be enlarged diminished or affected by and no obligation or liability will arise out of APC s rendering of technical or other advice or service in connection with the products The foregoing waranties and remedies are exclusive and in lieu of all other warranties and remedies The warranties set fourth above constitute APC s sole liability and purchaser exclusive remedy for any breach of such warranties APC s warranties run only to purchaser and are not extended to any third parties In no event shall APC its officers directors affiliates or employees be liable for any form of indirect special consequental or punitive damages arising out of the use service or installation of the products whether such damages arise in contract or tort irrespective of fault negligence or strict liability or whether APC has been advised in advance of the possibility of such damages InfraStruXure for W