Contents

1. DIMM To remove the DIMM from the controller module complete the following steps 1 Remove the controller module from the chassis FIGURE 1 Controller Removal 1 Handle 2 Guide Pin 3 Notch a On the left side of the controller module press the orange release tab to the right just enough to release the handle then rotate the handle upward b Slowly pull the handle away from the chassis to remove the controller module from the bay c Place the controller module on a level surface static free environment should be established before handling electronic Caution Some electronic components are sensitive to electrostatic discharge A components Cache Upgrade or Replacement 3 4 2 Remove the battery from the controller module FIGURE2 Battery Removal Battery Connector Cache Memory Battery Battery s Captive Fastener a Turn the blue captive fastener counterclockwise until the battery can move in the direction indicated by the arrow in the illustration above b Slide the battery unit out of the controller in the direction indicated by the arrow c Set the battery unit aside Sun StorageTek 2500 Series DIMM Upgrade Guide March 2009 3 Remove the DIMM from the connector FIGURE 3 DIMM Extraction 1 DIMM 2 Retaining Clip a Wait 60 seconds before you proceed to allow any residual charge to drain from the controller b Open both the retaining clips 2 on ea
2. sun com documentation Support http www sun com support Training http www sun com training Cache Upgrade or Replacement This upgrade guide explains how to remove the 512MB DIMM and install the 1GB DIMM for your Sun StorageTek 2500 Series Array Note Your 2500 array must have an optimal status and then be powered down before a DIMM upgrade is performed Refer to the Service Advisor for power down process steps to ensure that there is no I O the cache active LED is off and that both of the controller s power switches are placed in the OFF position Written for technicians system administrators authorized service providers ASPs and users who have experience with the Sun StorageTek 2500 Series array this upgrade document helps support the new capabilities of CAM 6 2 and later Note If you have any problems during this upgrade please contact customer support at http www sun com support Process Steps The DIMM upgrade process has two basic sections m Removing the 512MB DIMM See Removing the DIMM on page 3 a Installing the 1GB DIMM See Installing the DIMM on page 6 Note Before you start this upgrade process make sure you are aware of all safety information associated with working on a disk array as well as the electrostatic discharge precautions necessary when handling electronic components Sun StorageTek 2500 Series DIMM Upgrade Guide March 2009 V Removing the
3. IMITE DE LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALIT MARCHANDE L APTITUDE UNE UTILISATION PARTICULIERE OU L ABSENCE DE CONTREFA ON LD com Ca Adobe PostScript Contents Before You Upgrade v Cache Upgrade or Replacement Process Steps 1 v Removing the DIMM 2 v Installing the DIMM 5 1 iv Sun StorageTek 2500 Series DIMM Upgrade Guide March 2009 Before You Upgrade This document for upgrading dual in line memory module DIMM cache memory explains how to replace the cache memory in a Sun StorageTek 2510 Array a Sun StorageTek 2530 Array or a Sun StorageTek 2540 Array This upgrade replaces your 512 MB DIMM with a 1GB DIMM and enhances your array s capabilities This guide is for technicians system administrators authorized service providers ASPs and users who have experience with the 2500 Series array hardware It explains how to remove the 512 MB DIMM and install the 1 GB DIMM therefore it can also be used for doing a same size cache memory replacement Note Before using the procedures described in this document you must have a basic understanding of the array s hardware terminology The Sun StorageTek 2500 Series Array terminology is discussed in this related document m Sun StorageTek 2500 Series Array Hardware Installation Guide 820 0015 Documentation Support and Training Sun Function URL Documentation http www
4. SS amp o SUN microsystems Sun StorageTek 2500 Series DIMM Upgrade Guide for Sun StorageTek 2510 2530 and 2540 Arrays Sun Microsystems Inc www sun com Part No 820 7178 10 March 2009 Revision A Submit comments about this document by at http www sun com hwdocs feedback Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology that is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Sun Sun Microsystems the Sun logo and StorageTek are trademarks or registered trademarks of Sun Microsystems Inc or its subsidiaries in the U S and in other countries The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its us
5. ch end of the DIMM connector c Lift the DIMM 1 out of the connector 4 If the DIMM is functional not failed place the DIMM in a static protective package and set it aside for future use 5 Install the new or replacement DIMM following the procedure on the next page in this document Cache Upgrade or Replacement 5 VW Installing the DIMM After the controller is removed from the chassis and the battery is removed from the controller complete the following steps to install the new DIMM 1 Make sure at least 60 seconds has elapsed since you removed the battery from the controller 2 Make sure you have a static free environment The electrical grounding of both the chassis and personnel eliminates the build up of a static charge 3 Open the retaining clip on each end of the DIMM connector then remove the DIMM from the package Refer to FIGURE 1 FIGURE 2 and FIGURE 3 for the next three steps 4 Turn the DIMM so that the DIMM keys notches in the gold finger connector area align correctly with the slot 5 Match the angle of the DIMM with the angle of the connector 6 Firmly press the DIMM into the connector The retaining clips snap into the locked position when the DIMM is firmly seated in the connector If there is a gap between the DIMM and the retaining clips the DIMM has not been correctly inserted open the retaining clips remove the DIMM and then reinsert it 7 Reinstall the battery a Slid
6. e the battery into the controller until the battery connector pins are firmly seated in the controller battery connector b Turn the captive fastener clockwise to secure the battery in place 8 Reinstall the controller Caution After you remove a controller wait for 70 seconds before you reseat or replace the controller Failure to do so might cause unpredictable results 6 Sun StorageTek 2500 Series DIMM Upgrade Guide March 2009 a Slide the controller into the empty controller slot in the controller tray Make sure the handle is pulled straight out as you slide the controller into the chassis FIGURE 4 Controller Installation 1 Handle 2 Guide Pin 3 Notch b Make sure the guide pins on the side of the controller fit into the notches on the chassis c After the guide pins fit into the notches and the controller fits snugly into the bay push the handle downward to fully latch it into place 9 Repeat all of the steps to upgrade the cache in the other controller Note You should not attempt to apply power to the controllers until both controllers are upgraded to the same cache memory size Cache Upgrade or Replacement 7 8 Sun StorageTek 2500 Series DIMM Upgrade Guide March 2009
7. ers and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc poss de les droits de propri t intellectuels relatifs la technologie d crite dans ce document En particulier et sans limitation ces droits de propri t intellectuels peuvent inclure un ou plusieurs des brevets am ricains list s sur le site http www sun com patents un ou les plusieurs brevets suppl mentaires ainsi que les demandes de brevet en attente aux les Etats Unis et dans d autres pays Ce document et le prod
8. uit auquel il se rapporte sont prot g s par un copyright et distribu s sous licences celles ci en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Tout logiciel tiers sa technologie relative aux polices de caract res comprise est prot g par un copyright et licenci par des fournisseurs de Sun Sun Sun Microsystems le logo Sun et StorageTek sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc ou ses filiales aux tats Unis et dans d autres pays L interface utilisateur graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox dans la recherche et le d veloppement du concept des interfaces utilisateur visuelles ou graphiques pour l industrie informatique Sun d tient une license non exclusive de Xerox sur l interface utilisateur graphique Xerox cette licence couvrant galement les licenci s de Sun impl mentant les interfaces utilisateur graphiques OPEN LOOK et se conforment en outre aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS D CLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA L