1. Built in Control Equipment The COMPACT Unit and COMPACT Top have built in con trol equipment that can be operated from the hand held COMPACT Unit micro terminal with a clear text display The electrical and control system is completely integrat ed into the air handling unit The microprocessor based equipment controls and regulates temperatures airflows and other functions A large number of functions are built into the system and are simple to activate Range of Application The COMPACT Unit and COMPACT Top units are de signed for comfort ventilation and can be used in offices schools day nurseries public premises shops and resi dential buildings The COMPACT unit should be installed indoors The COMPACT is designed and tested for ambient tem peratures from 25 C to 40 C and temperatures in the air stream from 40 C to 40 C The COMPACT Unit and COMPACT Top units generate low noise levels This makes it possible to install the units near utility areas and workplaces The air handling units have an attractive and modest design making them ideal for installation where they can be seen in the premises Simple Installation A standard installation is simple Besides fitting the duct COMPACT Top system and air diffusers the fitter only needs to con nect the unit to a power supply and install a temperature sensor inside the supply air duct Ready to use connection terminals and control functions are provide
2. Hand held micro terminal Principle structure of the menu system D Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com COMPACT Accessories COMPACT Unit amp Top Duct Accessories General The duct accessories must be positioned in the ductwork outside the COMPACT unit The unit s fans make it pos sible to connect duct accessories directly to the unit s duct connections without pressure losses or non uniform air distribution The duct accessories for the COMPACT are fitted with rubber seal rings Other particulars for sizing can be obtained by using the ProUnit air handling unit selection program TBSA Damper Designed for preventing cold draughts while the air han dling unit is switched off The IQnomic controls the opera tion of the damper Technical Data Complete with damper actuator for 230 V The actuator can be selected with spring return or on off actuation Tightness Class 3 to EN 1751 Standard Installation Can be mounted in a horizontal or vertical duct Connect the controls and power supply to the air handling unit s control unit TBDA Unit silencer The TBDA unit silencer is a circular sound absorber de signed for installation in a duct Technical Data Made of galvanized sheet steel The sound attenuating material consists of 100 mm thick mineral wool This is covered with Fartex a patent pend ing s
3. AA gs lt 2 amp 3 a BG1 M3 7 aS NAVA n Making a simple adjustment in the control equipment enables you to change the directions of airflow through the COMPACT Unit at the building site small arrows The relevant components automatically change function as well gt o Outdoor air Supply air Extract air Exhaust air Components V1 Outdoor air filter V2 Extract air filter BT3 Outdoor air temperature sensor Indicates for control BT2 Extract air temperature sensor Indicates for control of functions that affect temperature of functions that affect temperature E1 Variable speed controlled RECOnomic rotary heat G2 Direct driven extract air fan with EC motor exchanger with air purging operation T2 Motor control system for variable regulation of the M3 Step motor for variable speed control of the rotary extract air fan heat exchanger BF2 Extract air flow pressure sensor Indicates for control BG Rotation monitor sensor for monitoring the heat of the extract air fan s speed and monitors the filter exchanger s rotation status G1 Direct driven supply air fan with EC motor K1 IQnomic control unit containing control circuit card T1 Motor control system for variable regulation of the and other electrical equipment for controlling inter supply air fan nal and external functions BF1 Flow pressure sensor supply air Indicates for control 2 eps inu ane ee of the supply air fan
4. s soeed and monitors the filter all tae la lila d Seats periods etc as well as alarms BT1 Supply air temperature sensor To be positioned in the ductwork Indicates for control of functions that affect temperature 47 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com dol 8 Hun LOVdINOD COMPACT Swegon Technical Description of the COMPACT Unit amp Top Units Electrical and Control System Hand held micro terminal All the settings and readings can be entered viewed in plain text via a user friendly hand held micro terminal The hand held micro terminal has keys for entering the various commands The display screen and the keys have background lighting A red indicating LED flashes in the event of an alarm The preset values are stored and will not be affected in the event of a power failure The control panel contains logically composed menus ar ranged in various levels as follows e Main menu Intended for reading the operating status and for entering temporary changes in how the unit operates User level Intended for entering settings and viewing readings for the functions selected Installation level An access code is required obtainable in the maintenance instructions Selection of functions and the setting of limit values Service level An access code is required disclosed on completion of special training course
5. EC motors that provide high efficiency across the entire operating range Flow measurement and control are standard The fans are effectively vibration isolated from the casing They can be dismantled and removed from the air han dling unit if required Heat exchanger The rotary heat exchanger is of RECOnomic type pat ented by Swegon The heat exchanger is driven by a step motor that controls the rotor speed with high precision and controls the heat recovery efficiency as well The rotation monitor and controls are standard equip ment It is available in a sorption version for moisture recovery which reduces operating and investment costs for cooling and improves indoor comfort levels in the winter Filters The air handling unit has pleated Class F7 filters for both the supply air and the extract air Filter monitoring is built into the control system Environmental Product Declaration Swegon AB has a certified environmental management system that conforms to ISO 14001 Standard and is regis tered on the REPA Register no 5560778465 The COMPACT units are made of the following materials Type of Material Percentage of total weight Approx 80 Approx 896 Electronic equipment motors Pleated Class F7 filter 45 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com dol LDVWdINOD COMPACT Swegon Technical Descri
6. WY Un o Q 26 N O 4 O 2 O F a a N Qe Ke N _ D O Q O _ O N N Q ES Cc _ D X Qa m Qe Qa WY 2 U G U ka 4 m E Octave band No mid frequency Hz Sound path x lt gt 5 E 1 5 O U ie ine ES m REA RES Top When adjusting the flow To the unit s round off the value to the nearest settable step o 3 O 60 www swegon com 20090901 Registered design The company reserves the right to make design changes without prior notice COMPACT Sizing COMPACT Top Delivery and transport within the site The air handling unit is delivered on a wooden pallet The unit is equipped with base beams The inspection door and fans can be dismantled from the unit to make it easier to transport the unit within the site The COMPACT Top unit is produced in one single variant in which all the components are arranged at their given physical location inside the unit All the duct connections are arranged from the top of the air handling unit Electrical Data Power supply 1 phase 3 wire 230 V 10 15 50 Hz 10 AT The unit i
7. exhaust air is horizontally discharged through a circu lar wire mesh grille at the front of the hood Outdoor air is admitted through a wire mesh grille at the bottom of the hood This design effectively prevents short circuit air flow between the outdoor air exhaust air Made of aluminium zinc plated sheet steel painted dark grey RAL 7021 equivalent to NCSS 8502 B Environmen tal Class C4 Available in two variants with or without acoustic insula tion Installation The 250 mm dia connections are fitted with rubber seal rings When you cut an opening in a wall bear in mind that the ducts must be insulated with at least 30 mm thick insulation and with damp proof outer layer material The front panel of the external wall hood can be lifted off after removing its screws reversed and resecured This makes the duct connections for exhaust air and outdoor air optional THE Mechanical equipment TBLZ Stand Specially designed stand for the COMPACT Unit The height of the stand makes it possible to install ducts under the air handling unit The stand is made of galvanized sheet steel profiled sec tions The stand is supplied in assembly kit form Can be installed with or without legs Height without feet 100 mm The long sides A in the illustration are used for horizon tal installation and the shorter sides B are used for verti cal installation TBLZ Cover holder The cover holder is a practical ac
8. kg Registered design The company reserves the right to make design changes without prior notice Clear Space for Inspection A clear space of 800 mm must be provided in front of the unit for opening the inspection doors and at least 200 mm must be provided above the unit for opening the junction hood 59 20090901 www swegon com dol LDVWdINOD COMPACT COMPACT Top size 03 COMPACT Top size 02 Airflow m h Airflow m h 300 1 000 500 300 600 100 800 400 200 100 AAS A se Hu ft pai LLL LIE EL LLL il 1 LAMMEMEEMM g Hi nr ees E Hn Portes s A 1 SE HE M EN tue TN E ND M He Di Partei HEP 0 3 0 05 0 0 0 5 TN ed asi e qe reAV Ep e boue pF LE i it A AN M Wd VE l a Ae TIRG i Turm Ju Du LECHE LAE t Eu c ou af e00E O a 300 0 2 0 5 0 1 tot W N air NW N ed aS ainssajd je 0 ajqeyjieay 400 SU 400 100 10 Airflow m s Airflow m s o H lt U vi gt O i x c 2 The COMPACT Top Correction factors dB na E D 2
9. on the control unit Separate power supply Registered design The company reserves the right to make design changes without prior notice Pushbutton For overtime operation when the unit s built in time switch has controlled the unit to operate in the low speed mode or to stop For strap on mounting Can be selected with or without indication To be connected to appropriate terminals on the control unit Connection Cable 0 25 15 m for hand held micro terminal pressure trans ducer and IQnomic Plus Extension Cable 5 8 m long for air heater for hot water electric air heater and supply air temperature sensor 8 m long for hand held micro terminal Extension kit for hand held micro terminal For lengthening the cable 6 50 m Extra hand held micro terminal Including holder and 3 m long cable Strap on sensor Temperature sensor for mounting against the surface where readings are to be taken SD card For program transmissions and logging IQnomic Plus The extra functions for which the inputs and outputs are not included as standard in the unit s control unit for ex ample external monitoring and cooling TBLZ Communication unit For communication via LON FTT 10 Lon Works and Trend communication via TCP IP and EIA 485 as well as via internal webserver is standard in the COMPACT To be connected to the communication port of the con trol unit Power can be supplied from appropriate termi nals on the control un
10. COMPACT Unit amp Too COMPACT Unit COMPACT Top Contents n MERRRRRRRR 42 Technical Description of the Air Handling Units sses 44 PCS SONS Ss MIR E E A 49 PE O MN m 56 COMPACT Sweegon COMPACT Unit and COMPACT Top Have That Little Extra Introducing the new COMPACT series Swegon offers air handling units for small air volumes without having to reduce standards of performance energy efficiency con trol functions and communications options Energy efficient Fans The fans in the COMPACT series are direct driven plug fans They are equipped with EC motors that provide high efficiency across the entire operating range The fans are compact and take up little space Sharp duct bends can be connected directly to the fan outlet without pressure losses The fans also generate low noise levels Heat Exchanger with High Efficiency All of the units in the COMPACT series are equipped with COMPACT Unit the RECOnomic rotary heat exchanger one of the most efficient heat exchangers on the market The temperature efficiency of the RECOnomic is high up to 8596 and the pressure drop across it is low The heat exchanger is driven by a step motor that permits extreme ly high precision for controlling the rotor speed and heat recovery efficienc
11. E electric air heater is used reheating the supply alr Technical Data Uninsulated casing made of galvanized sheet steel and heating elements made of stainless material The TBLE air heater is available in two capacity variants The integrated thyristor is controlled via signals from the COMPACT air handling unit The TBLE has two series cou pled overheat protection devices The electrical equip ment conforms to the provisions of Degree of Protection IP43 Installation The TBLE air heater can be installed for horizontal or verti cal airflow Provision for inspection and cleaning must be guaranteed The end panel on the connection side can be dismantled for inspection and wiring electrical connections The distance from or to a duct bend damper filter or the like should be at least the distance that is equivalent to double the diameter of the duct Otherwise there is risk that the airflow through the electric air heater will be non uniform involving risk that the overheat protection device will trip Power must be supplied directly from the electrical distri bution box Connect the control signal cable with quick fit connector to the air handling unit s control unit Registered design The company reserves the right to make design changes without prior notice 20090901 375 Weight 6 kg www swegon com Los 51 dol LDVWdINOD COMPACT Accessories COMPACT Unit amp Top D
12. MPACT Unit makes it necessary to mount it on a stand available as accessories or some other form of base Otherwise it will not be possible to open the inspection doors Swegon s stand is specially de signed and among other features has slots for the hinges if the unit is installed vertically Electrical Data Power supply 1 phase 3 wire 230 V 10 15 50 Hz 10 AT The unit is equipped with a main switch Rated data per fan Size 02 1 x 230 V 50 60 Hz 0 5 kW 0 28 kW Size 03 1 x 230 V 50 60 Hz 0 5 kW 0 43 kW The motor controls limit the output power to the value specified Rated data for the heat exchanger drive motor Step motor 3 phase 5 8 A 2A 62 V max 90 V The motor control system limits the output power to the value specified Dimensions and Weights COMPACT Unit sizes 02 and 03 Right hand version Left hand version gt gt Outdoor air Supply air Extract air Exhaust air Connection to Power Supply Weight 160
13. Version tia zx S 2 05 Emm 05 10 m Sm 5 Connection cable TBLZ 2 26 aa For hand held micro terminal pressure sensor TBIQ d Version 0 45 m 00 Extensioncable TBLZ 1 05 a With quick fit connector Version 5 m long for air heater electric or water coil 1 5 m long for supply air sensor 22 8 m long for terminal pressure sensor TBIQ 3 Extension kit for hand held micro terminal TBLZ 2 13 For extending the cable 6 50 m Strap on sensor TBLZ 1 32 Registered design The company reserves the right to make design changes without prior notice SD card TBLZ 1 62 a Flash card for program transmissions and logging Version Without COMPACT program 1 With COMPACT program 2 Plus TBIQ 2 1 aa Functional module and connection cable Version C250 00 1m Oil 3m 05 Nn U5 10m 10 15 Modular terminal adaptor TBLZ 1 55 Communication unit TBLZ 3 1 a 41 For interface LON FFT 10 Tend yj Fire and smoke protection Equipment cabinet for fire and smoke protection function TBLZ 1 48 1 Including control unit for smoke detector Control box for fire and smoke protection function TBLZ 2 48 2 Including control unit for smoke detector and damper exercising damper 24 V AC Also requires the TBIQ accessory Including control unit for smoke detector Smoke detector optical TBLZ 2 49 1 Venturi tube 600 mm Mounting fittings for smoke detector for circular
14. an be selected To be connected via appropriate terminals on the control unit Air quality sensor For controlling high and low speed operation instead of the unit s built in time switch The air quality sensor reg isters the carbon dioxide content in the room air and the control unit regulates the airflow required within preset limits Available installation in a duct or in a room To be con nected to appropriate terminals on the control unit VOC sensor For variable control of the airflow The VOC sensor senses the content of emissions impurities in the room and the airflow is regulated within preset limits To be mounted inside the air handling unit To be connec ted to appropriate terminals on the control unit Room sensor For use when the unit s built in extract air temperature sensor does not provide representative values Designed for wall mounting and is available for Enclosure Class IP 20 To be connected to appropriate terminals on the control unit Timer Mechanical For time limited overtime operation when the unit s built in time switch has controlled the unit to operate in the low speed mode or to stop For strap on mounting To be connected to appropriate terminals on the control unit Timer electronic For time limited overtime operation when the unit s built in time switch has controlled the unit to operate in the low speed mode or to stop For strap on mounting To be connected to appropriate terminals
15. cessory for the upper in spection door for COMPACT Unit installed vertically The cover holder consists of a mechanical stay with latch and is supplied in unmounted condition TBLZ Door Lock For use where more stringent demands on security are made as opposed to locking with a standard special key Supplied in sets of 2 locks with key for replacement of the existing lock at the building site 54 Registered design The company reserves the right to make design changes without prior notice Stand Two pairs of long sides are supplied A is used for horizontal installation and B is used for vertical installation 20090901 www swegon com COMPACT Accessories COMPACT Unit amp Top Electrical and control equipment Presence detector For controlling high and low speed operation instead of the unit s built in timer As soon as the sensor registers the presence of an occupant in the room the air handling unit is controlled to the high speed mode when there are no occupants to the low speed mode To be connected via appropriate terminals on the control unit Pressure sensor For use in conjunction with the VAV pressure control function when constant pressure must be kept in the ductwork Also for use in conjunction with the heat ex changer defrosting function when the pressure across the heat exchanger must be controlled The connection cable is included A 1 15 m long cable c
16. d for accessories such as dampers air heaters and air coolers EUFOWVENT CERTIFIED Certification PERFORMANCE Swegon AB has a certified Quality Assurance System that conforms to ISO 9001 Standard and a certified Environ PTPN EE ENERET ER mental Management System to ISO 14001 www eurovent certification com The COMPACT Unit amp Top air handling system is also cer www certiflash com tificated by Eurovent No AHU 09 05 426 44 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com COMPACT Sweegon Technical Description of the COMPACT Unit amp Top Units Mechanical Design Casing The room unit casing has an outer skin of galvanized sheet steel that has been prepainted in a shade of white NCS S 0502 G and has an inner skin of aluminium zinc plated sheet steel The rear side of the COMPACT Top consists of aluminium zinc plated sheet steel The exterior surfaces of the room unit conform to Envi ronmental Class C4 The casing has 30 mm thick mineral wool insulation the inspection door has 50 mm thick insulation The inspection door s is are hung on hinges The door s is are opened and closed using a special key A lockable door lock is available as an accessory Fans The fans are direct driven plug fans They are equipped with
17. e threads Accessories Valve set Set of electrical connection components Valve set with 2 3 way valve actuator anti frost protec tion sensor and connection cable with quick fit connector can be ordered If you install a valve of your own you can instead select a set of electrical connection components This set contains a connection cable with quick fit con nector resistor and insertion or strap on sensor Circulation pump Circulation pump used for protecting the anti frost pro tection monitor function for the air heater Supplied with T coupling non return valve and adjustment valve The automatic pump control system Is integrated into the COMPACT control equipment 330 Installation The TBLA air heater can be installed for horizontal or ver tical airflow Provision for inspection and cleaning must be guaranteed Pipe connection male threads DN 15 The installation of accessories if required fitting of pipe connections and filling the circuit with liquid must be done at the building site Weight 7 kg excluding liquid Basic Installation Diagram 2 3 way valve Anti frost protection sensor in T piece Shut off valve Adjustment valve Secondary pump Shut off valve 50 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com COMPACT Accessories COMPACT Unit amp Top Duct accessories TBLE Electric air heater The TBL
18. elf supporting surface layer that has been approved in terms of ease of cleaning minimal fibre entrainment by the airflow resistance to ageing and minimal emissions The connection spigots are fitted with rubber seal rings Fire resistance Class The TBDA has been granted type approval TG 0783 for Fire resistance Classes EI30 E120 EI60 E120 respectively EI120 E120 on condition that it is installed at a safe dis tance of 50 mm from a combustible structural element Q424 250 In buildings in which the safe distance trom combusti ble material and or persons in an evacuation route is not complied with the TBDA then has Fire resistance Class 60 120 Installation Provision for inspection and cleaning must be guaranteed Registered design The company reserves the right to make design changes without prior notice 20090901 125 Weight 5 kg Weight 15 kg www swegon com 49 dol LDVWdINOD COMPACT Accessories COMPACT Unit amp Top Duct accessories TBLA Air heater for hot water The TBLA air heater is used if required for reheating the supply air with hot water as the heating medium Technical Data Uninsulated casing made of galvanized sheet steel Finned tube heat exchangers fabricated of copper tubes and profiled aluminium fins The headers and the pipe work to the water connections are made of copper The pipe connections are made of brass and have mal
19. id must be done at the building site 22 Registered design The company reserves the right to make design changes without prior notice TBKA chilled water Water pipe connections male threads capacity variant 1 DN 15 capacity variant 2 DN 20 C 60 AN m Pipe connection drainage male threads DN 15 444 315 Weight Capacity variant 1 21 kg capacity variant 2 24 kg not including liquid TBKC direct expansion D1 Refrigerant pipe connections smooth pipe end D1 male threads 12 mm D2 Refrigerant pipe connections smooth pipe end D2 male threads 12 mm D2 D1 430 490 Js Pipe connection drainage male threads DN 15 Weight 37 kg excluding liquid 20090901 www swegon com COMPACT Accessories COMPACT Unit amp Top Roof Hoods General The roof ducts are made of galvanized sheet steel Lined inside with 50 mm thick insulation to Fire resistance Class E130 with a surface covering of type approved synthetic woven fabric Two angle brackets for connection to the relevant roof slope are included The hoods are made of aluminium zinc plated sheet steel covered with a Plastisol black surface coating that con forms to Environmental Class C4 The hoods have round duct connection fitted with rubber seal rings for spiral ducts Duct connections have a 315 mm diameter thus a 250 315 mm duct transition piece is required not
20. igned for use with the control system of the EC motor Communication Communication via TCP IP and EIA 485 is included as standard The TBLZ Communication unit is used for com munication via LON and Trend The COMPACT also has built in web communication Communication with the COMPACT can be established via an ordinary web browser such as Internet Explorer and your own network i e without any main control sys tems whatever In addition to the above the COMPACT units have inputs and outputs for external functions such as the forwarding of alarms or overtime operation that can be keyed in 46 Registered design The company reserves the right to make design changes without prior notice Ba eg TE ee Tee ea oe IQnomic control unit 250 V s 0 85 75 1200 m LI O 85 75 250 I s 1200 m s COMPACT Demo unit Auto operation high flow LI B alarm U A alarm Reset Typical flow diagram for web communication 20090901 www swegon com COMPACT Swegon Technical Description of the COMPACT Unit amp Top Units Electrical and Control System Flow Diagrams When you calculate performance data in the ProUnit AHU selection program the program furnishes a project specif ic flow diagram and a description of the unit s functions The individual components are specified below COMPACT Unit COMPACT Top t 9 1 lt Imari V1 zh
21. included in the supply TBHA Outdoor air hood Designed for the intake of outdoor air The design of the hood makes it difficult for snow and rain drops to enter the hood with the incoming air The hood is hinged and has air intake louvres on both sides TBHB Exhaust air hood Designed for the discharge of exhaust air The hood can be opened on hinges and is equipped with air deflectors that effectively direct the exhaust air upward and give the air high discharge velocity To achieve low pressure drop the air deflectors are rounded off on both their long sides The hoods are equipped with effective provision for drainage TBHC Dual purpose hood The TBHC is a combination of TBHA outdoor air hood and TBHB exhaust air hood TBHA Outdoor air hood and TBHB Exhaust air hood 850 620 2 angle brack ets unmount ed are supplied with the hood Weight 31 kg Registered design The company reserves the right to make design changes without prior notice TBHB Exhaust air hood TBHA Outdoor air hood TBHC Dual purpose hood TBHC Dual purpose hood 620 2 angle brack ets unmounted are suppled with the hood 9 10315 9315 900 Weight 70 kg 95 20090901 www swegon com dol Hun LOVdINOD COMPACT Accessories COMPACT Unit amp Top TBHF External wall hood For the admission of outdoor air and the discharge of ex haust air The
22. ise E Supply air fan SAE RA IN JEU _ E iia pt i A LITT E Oe eee a 2 1 C E Li a a ad Piet 0 aE pp Yi ew tot 1466 DEA E 0 0 05 0 1 0 5 0 0 0 25 e cn Airflow m s Min and Max Airflows COMPACT Air The tabulated flows are those that are possible to set The effect of external pressure drop determines the feasible flow limits that can come into use COMPACT Unit Min airflow Max airflow When adjusting the flow round off the value to the nearest step 20090901 www swegon com COMPACT Sizing COMPACT Unit Delivery and transport within the site The air handling unit is delivered on a wooden pallet The inspection door and fans can be dismantled from the unit to make it easier to transport the unit within the site The COMPACT Unit is produced in one single variant in which all the components are arranged at their given physical location inside the unit The air handling unit is supplied in the right hand version The unit can be changed to the left hand version at the building site by making simple adjustment in the con trol equipment The air handling unit can also be upended and which enables six different installation options as il lustrated in the figure to the right The design of the CO
23. it Fire and smoke protection The fire and smoke protection function consists of three separate units e TBLZ Equipment cubicle e BLZ Smoke detector e ELQZ Damper actuator The cubicle contains the control unit and connections The smoke detector stops the air handling unit and controls the damper actuators to close the dampers An alarm is presented in the hand held micro terminal of the COM PACT air handling unit Applicable to installations in Sweden The ELQZ damper actuator can be used where type approved solutions are not required If a type approved solution is required the damper and actuator must be supplied as a unit in a type approved version In these cases a pump exercising mode is also required 95 20090901 www swegon com dol Hun LOVdINOD COMPACT Specification COMPACT Unit amp Top Air handling unit Air handling unit COMPACT Unit CU aa A c 1 Size 02 zu 03 S Heat exchanger standard SOMONE Air handling unit COMPACT Top CT aa A c 1 Size 02 202 03 05 Heat exchanger Standard SOMON Replacement Material Set of filters pleated filter COMPACT TBFZ 1 07 For supply air and extract air Hoods Outdoor air hood TBHA 1 031 Including root duct 315 mm dia duct connection Extract air hood TBHB 1 031 Including root duct 315 mm dia duct connection Dual purpose hood TBHC 1 031 Including root duct 315 mm dia duct connection External wall ho
24. n Communication with the COMPACT can be established via an ordinary web browser such as Internet Explorer and your own network i e without any main control systems whatever In addition to the above the COMPACT units have inputs and outputs for external functions such as the forwarding of alarms or overtime operation that can be keyed in Hand held Micro Terminal IOnomic 250 l s 1200 m s O 85 75 250 1 5 1200 m3 s COMPACT D 43 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com dol Hun LOVdINOD COMPACT Sweegon Technical Description of the COMPACT Unit amp Top Units General The COMPACT Unit and COMPACT Top units are com plete air handling units with direct driven supply air and extract air fans supply air and extract air filters rotary heat exchanger and built in control equipment The two sizes have the same physical dimensions but dif ferent airflow capacity The COMPACT Unit has duct connections arranged on its side panels The COMPACT Top has all its duct connec tions arranged at the top of the unit The air handling unit is equipped with a pressure adjus ting plate used for achieving a correct direction of air lea kage across the heat exchanger This prevents extract air from being carried over to the supply air
25. o the system and is ready to activate All the settings and readings can be entered viewed in plain text via a user friendly hand held micro terminal The fact that the control equipment is integrated into and specifically developed for the COMPACT ensures that its electronics and mechanics operate hand in hand Smart and Economical Control Functions Typical smart and economical control functions available only in the IQnomic from Swegon e ERS Regulation control Can be used when the rooms served have surplus heat In most cases no re heating coil is needed e Density corrected airflow Automatically takes into consideration how the air density varies and accord ingly provides different air volume at different tempera tures e Seasonally compensated airflow The airflow can be reduced in the winter according to a preset per formance curve e Summer night cooling An energy saving function for supplying cool outdoor air to the rooms at night e Cooling BOOST and Heating BOOST The airflow can be adjusted according to the cooling and heating loads respectively e Cooling recovery The heat exchanger is also auto matically utilised for recovering the relative cooling energy that can be present inside the room Communication Is Standard Communication via TCP IP and EIA 485 is included as standard The TBLZ Communication unit is used for communication via LON and Trend The COMPACT also has built in web communicatio
26. od TBHF 2 0025 b Combination hood for outdoor air exhaust air I Insulation Without With Mechanical equipment Stand TBLZ 1 03 05 Assembly kit for COMPACT Unit only Cover holder TBLZ 1 10 07 For the upper door for vertical installation for COMPACT Unit only Door lock TBLZ 1 57 Set of two door locks with key Duct accessories Damper with motor TBSA 1 000 025 1 a Tightness Class 3 250 mm dia duct connection uninsulated damper blades Damper motor With spring return On off Air handling unitsilencer TBDA 1 000 025 080 Duct connection size 250 mm dia 800 mm long 56 Registered design The company reserves the right to make design changes without prior notice Duct accessories Air heater for hot water TBLA 4 000 025 2 1 Duct connection size 250 mm dia Valve set cooling and heating TBVL 3 aaa b 2 3 way valve including actuator cable and insertion type sensor Valve size Kvs 0 25 002 Kvs 0 40 004 Kvs 0 63 006 Insertion type sensor a Strap on sensor Set of electrical connections TBLZ 1 27 a For air heater for hot water Cable resistor and insertion sensor Cable resistor and strap on sensor 2 Circulation pump TBPA 5 aaa Set of pump components for the secondary side tor air heater without anti frost protection includ ing non return valve and adjustment valve Capacity at max 25 kPa pressure drop in air heater and pipework lt 0 09 1 5 z009 0 091 0 17 I
27. or insulated ducts TBLZ 1 53 Damper actuator ELQZ 1 428 3 a With spring return f With spring return and limit switch 0 5 20090901 www swegon com dol 8 Hun LOVdINOD COMPACT Sizing COMPACT Unit size 02 Airflow m h 0 100 200 300 400 500 600 700 800 N n E Available total pressure rise Airflow m s COMPACT Unit Correction factors Sound path To outlet duct 12 in 58 Registered design The company reserves the right to make design changes without prior notice COMPACT Unit size 03 Airflow m h 2 i 7 SNEEEENENEEENM T A a TT ELI i 4 Hn Se CUM see T TTA E MAAA lt HAA OZ TA Z A a a 8 TAR See eee Or RESTI EE air fan LT N BERTE MENE 0 mm o T TL TL mim PRU T 00111171 Saug B stmt m LI LI E A C Za O ape SRE ell i i Available total pressure r
28. ption of the COMPACT Unit amp Top Units Electrical and Control System General The IQnomic control system is completely integrated into the air handling unit The microprocessor based equip ment controls and regulates temperatures airflows and other functions A large number of functions are built into the system and are simple to activate See the special sec tion entitled Description of the Control System The air handling unit can be automatically controlled in several ways via the integrated time switch however it can also be demand controlled via a CO sensor or pres ence detector Manual control is also possible A large number of functions and settings can be also acti vated entered via communication Control Inaccuracy Temperature x 1 C Airflow x 596 Power Efficiency The design and performance of the air handling unit are optimized for achieving excellent power efficiency Standards The air handling unit conforms to the provisions in the SS EN 60204 1 Standard Interference Level The air handling units conform to the provisions of the EMC Directive and are tested according to EN 61000 6 2 and EN 61000 6 3 Standards radiation in residential buildings office buildings shops and similar indoor envi ronments and for immunity in industrial facilities Use of an earth fault circuit breaker The earth fault circuit breaker if required should only serve the air handling unit and must be of a type de s
29. s Oly Electric air heater TBLE 3 000 025 bbb c Duct connection size 250 mm dia Capacity variant 2 1 kW 230 V only 3 0 kW 030 Voltage 400V 230V Norway Air cooler for chilled water TBKA 4 000 031 1 Capacity variant 1 315 mm dia duct connection Air cooler for chilled water TBKA 4 000 031 2 Capacity variant 2 315 mm dia duct connection Valve set cooling and heating 2 3 way valve including actuator TBVA 1 aaa Valve size Kvs 0 25 007 Kvs 0 40 002 Kvs 0 63 006 Kvs 1 0 zT Kvs 1 6 Kvs 2 5 025 Kvs 4 Kvs 6 3 063 Air cooler direct expansion TBKC 4 000 031 1 1 Duct connection size 315 mm dia 1 section 20090901 www swegon com COMPACT Specification COMPACT Unit amp Top Electrical and Control Equipment Presence detector TBLZ 1 56 Pressure sensor TBLZ 1 23 aa Contains pressure sensor and connection cable Version Sensor only 00 1m zl 3m 05 5m 05 10 0 5 Air quality sensor room ELQZ 2 504 VOC sensor TBLZ 1 60 1 1 Room sensor TBLZ 1 24 2 For wall mounting Enclosure Class IP 20 Timer mechanical ELQZ 1 406 1 For strap on mounting 0 2 hour prolonged operation Timer electronic TBLZ 1 47 Pushbutton for prolonged operation ELQZ 2 455 a b EM Without indicating LED With indicating LED Version For surface mounting Connection cable TBLZ 1 26 aa For hand held micro terminal pressure sensor TBIQ
30. s equipped with a main switch Rated data per fan Size 02 1 x 230 V 50 60 Hz 0 5 kW 0 28 kW Size 03 1 x 230 V 50 60 Hz 0 5 kW 0 43 kW The motor controls limit the output power to the value specified Rated data for the heat exchanger drive motor Step motor 3 phase 5 8 A 2A 62 V max 90 V The motor control system limits the output power to the value specified gt gt Outdoor air Supply air Extract air Exhaust air Circula tion air Dimensions and Weights COMPACT Top sizes 02 and 03 1103 250 4 OEE Weight 200 kg Clear Space for Inspection Connection to Power Supply A clear space of 1 000 mm should be provided in front of the unit for opening the inspection door right hung Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com 61 dol LDVWdINOD COMPACT 62 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com
31. uct accessories TBKA Air Cooler for chilled water TBKC Air cooler direct expansion The TBKA TBKC air coolers are used for cooling the supply air with chilled water or evaporative refrigerant as the cooling medium The TBKA TBKC air coolers are available in several capac ity variants that cover existing needs for the COMPACT Technical Data Uninsulated casing made of galvanized sheet steel The TBKA TBKC air coolers consist of copper tubes and profiled aluminium fins The TBKA has water connections made of copper brass with male connection threads The TBKC has water connections made of copper designed for soldered joints Accessories Controls An IQnomic plus module is required for controlling water based cooling The IQnomic Plus is an extra module for the air handling unit s control system The regular outputs of the air handling unit are used for cooling with direct expansion in one step If this is not sufficient then the IQnomic Plus should be used Valve set The TBVA Valve set consisting of a 2 3 way valve includ ing actuator can be ordered Installation The TBKA TBKC air cooler must be installed for horizon tal airflow Duct connections have a 315 mm diameter thus a 250 315 mm duct transition piece is required not included in the supply Provision for inspection and cleaning must be guaranteed The installation of accessories if required fitting of pipe connections and filling the circuit with liqu
32. y as well Compact Filters The air handling units are equipped with Class F7 so called pleated filters for both the supply air and the ex tract air Filter monitoring is built into the control system Unparalleled Flexibility COMPACT Top is often the best option when space is restricted side to side and the duct work is run from above COMPACT Unit can be upended and you can choose the direction of airflow This provides six different installation alternatives Their low noise level makes it possible to in stall the units near utility areas and workplac es Their attractive design makes it possible to place the units where they can be seen 42 Registered design The company reserves the right to make design changes without prior notice 20090901 www swegon com COMPACT Swegon The IQnomic Control System An Intelligent Economist on which You Can Always Rely Complete Control System The IQnomic control system controls and regulates fans heat exchanger temperatures airflows and in operation periods Every conceivable function for an air handling unit is built int
Download Pdf Manuals
Related Search
Related Contents
品番 AGA-A型 MICROWAVE OVEN カタログをダウンロード(Acrobat Reader 4.0が必要になります) 取扱説明書 Samsung HW-J550/ZA Product manual 250w vhf fm transmitter system with 4 way stacked dipole Εγχειρίδιο χρήστη Användarhandbok Manual do Utilizador IBM SPSS Data Collection Interviewer Server 6.0.1 User's Guide StarTech.com USBthere - 1 Port Bus Powered 330 Foot (100 meter) USB Webcam Extender SCA+チタン Ⅱ 取扱説明書 Copyright © All rights reserved.