Contents
1. OUTER A CASING fo NOTES 1 SOME MODELS MAY BE SUPPLIED WITH A COMBINATION GAS VALVE 2 SOME MODELS MAY BE SUPPLIED WITH A DUAL OPERATING SAFETY HIGH LIMIT AQUASTAT 3 ITEMS SHOWN MAY NOT BE PRESENT ON ALL MODELS BASE ASSEMBLY SEDIMENT TRAP NOT SUPPLIED AAE U 021 05 FIGURE 3 TYPICAL GAS TRAIN ASSEMBLY AND CONTROL COMPONENT LAYOUT FOR COMMERCIAL INSTALLATIONS 11 MG SG amp AAA Series Boilers User s Information Manual 20 INDEX Section Page General 68 EI 2 1 About Our Manualni siiani ei ind ie ee eee ee eee 3 2 palety IMSUUCUIONS 3 3 Lighting INStrUCtIONS 3 4 Lighting Instructions for Intermittent Electronic Ignition with Combination Gas 4 5 Lighting Instructions for Intermittent Electronic Ignition with Non Combination Gas 4 6 To Turn off Gas to the Boiler or Emergency Shut Off 2 5 7 Area around B10 eer 5 8 Check tor Gas ete 5 9
2. e 6 10 Air Supply for Combustion and 6 11 Check for Draft Hood 6 12 BUPMER 7 13 Boiler Water cee eet eee Se ae 7 14 Pressure Relef Yale ii E 8 15 Blocked Vent and Flame Roll Out Safety Switches 8 16 Inspection amp Maintenance 5 nennen 8 17 User Checklist ee ei ee 18 Typical Residential Boiler Component 10 19 Typical Commercial Boiler Component Locations 11 20 12 12
3. _ SEDIMENT TRAP NOT SUPPLIED FIGURE 2 TYPICAL GAS TRAIN ASSEMBLY AND CONTROL COMPONENT FOR RESIDENTIAL INSTALLATIONS 10 MG SG amp AAA Series Boilers User s Information Manual 19 TYPICAL COMMERCIAL BOILER COMPONENT LOCATIONS DESCRIPTION ITEM DESCRIPTION 1 MAIN ON OFF SWITCH amp CONTROLLER MOUNTING PANEL 11 MANUAL SHUT OFF VALVE FIRING VALVE 2 BC 1 CONTROLLER 121 HIGH GAS PRESSURE SWITCH WHEN USED 3 IGNITION CONTROL MODULE ELECTRONIC IGNITION ONLY 13 MAIN GAS VALVE 4 TRANSFORMER 14 REDUNDANT GAS VALVE 5 OPERATING HIGH LIMIT AQUASTAT 15 P2S PILOT SHUT OFF VALVE 6 TEMPERATURE PRESSURE GAUGE 16 MANUAL MAIN SHUT OFF VALVE AB COCK 7 SAFETY HIGH LIMIT AQUASTAT 17 LOW GAS PRESSURE SWITCH WHEN USED 8 PILOT REGULATOR SOLENOID 18 MANIFOLD ASSEMBLY 9 1 4 TEE amp PLUG 19 PILOT BURNER UNIT 10 90 ELBOW ITEM 2 IS PROVIDED ON SINGLE AND TWO STAGE BOILERS ITEM 12 IS REQUIRED ON BOILERS WITH AN INPUT OVER 2500 M B H ITEM 12 amp 17 ARE REQUIRED ON U S BOILERS CSD 1 WITH AN INPUT OVER 2500 M B H ooo GAS INLET
4. USER S INFORMATION MANUAL GAS BOILERS FOR MODELS MG 50 E TO MG 150 E SG 135 E SG 495 E AAA 480 E TO AAA 3000 E WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier DATE OF INSTALLATION INSTALLED BY COMPANY ADDRESS PHONE Manufactured by Allied Engineering Company Division of E Z Rect Manufacturing Ltd Manufacturers of Gas and Electric Boilers Stainless Steel Tanks Heat Exchangers and Electric Boosters 94 Riverside Drive North Vancouver B C V7H 2M6 e Telephone 604 929 1214 e www alliedboilers com Branches Calgary e Edmonton e Toronto Denver PN2362763 MG SG amp AAA Series Boilers User s Information Manual WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal in
5. avoided bleaches and chlorinated cleaning products paints and sprays water softeners calcium or sodium chloride leaking refrigeration equipment freon from common aerosol dispensers These chemicals are especially commons near swimming pools beauty shops dry cleaning establishments laundry areas workshops and garages The warranty is void when failure is due to corrosion 10 AIR SUPPLY FOR COMBUSTION AND VENTILATION A sufficient air supply MUST be provided to this boiler Air openings to the boiler room provide the air for combustion flue gas dilution and ventilation and are always required regardless whether the air is taken from inside or outside The air opening size and location as well as exhaust venting considerations must conform to the applicable codes If any alteration of the air supply and venting system is required contact a qualified service agency The boiler room must never be under a negative pressure Air openings should be sized by your installer not only to the dimensions required for the total input of all fuel fired appliances in the boiler space but also to handle the air movement rate of any exhaust fans or air movers using air from the building or space Make sure the venting terminations are always kept clear of obstructions i e snow ice etc Louvers and grilles used in your air supply and ventilation system should be checked regularly and cleaned of any dust dirt or debris which will block proper
6. monoxide detector and alarm must comply with NFPA 720 Current Edition 2 Acarbon monoxide detector shall a located in the room where the boiler and or equipment is located b either hard wired or battery powered or both c Shall comply with NFPA 720 Current Edition 3 product approved vent terminal must be used and if applicable a product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions copy of the installation instructions shall remain with the appliance and or equipment at the completion of the installation MG SG amp AAA Series Boilers User s Information Manual 1 ABOUT OUR MANUALS Your Super Hot boiler has been provided with two manuals e User s Information Manual This manual is intended for the owner or user of the boiler and provides information on routine operation and maintenance and emergency shutdown e Installation and Service Manual This manual must only be used by a qualified heating installer service technician or gas supplier Installation or service by anyone unqualified to do so may result in severe personal injury death or substantial property damage Both manuals should be kept in the envelope provided and affixed adjacent to the boiler so that they are readily available for future reference 2 SAFETY INSTRUCTIONS WARNING If you do not follow these instructions exactly a fire or explosion may result ca
7. quickly and smoothly across all the burners Popping noises or explosions from the burners during ignition extinction or normal burner operation indicate the need for service Check flame color An extremely yellow flame as seen on a burning candle or match is an indication of incomplete combustion and is usually accompanied by the formation of soot and carbon monoxide carbon monoxide is a lethal colorless and odorless not necessarily gas If soot is allowed to accumulate it will partially restrict free passage of products of combustion to the flue Under typically operating conditions the flame should have a distinct bright blue inner cone and a blue orange outer cone glowing red Check for lifting Flames should not lift excessively from the burner ports The flames may lift slightly during ignition or when the burners are cold FIGURE 1 PILOT FLAME ADJUSTMENT If any of the above problems are observed or the burner system does not operate properly immediately contact a qualified service agency for adjustment or corrective measures 13 BOILER WATER Avoid unnecessary replenishment of system water It can allow oxygen to enter the system and cause serious corrosion problems As well minerals dissolved in the water supply will precipitate when heated minerals preferentially deposit in the heat exchanger Do not draw water from the heating system for cleaning flushing etc Any a
8. airflow 11 CHECK FOR DRAFT HOOD SPILLAGE WARNING Continuous spillage at the draft hood relief opening may result in severe personal injury death or substantial property damage After the main burners have operated for 5 minutes check to see that combustion products are going up the chimney or gas vent properly by passing a lighted match or smoke from a cigar cigarette or pipe around the edge of the relief opening of the draft hood If the chimney or gas vent is drawing properly the match flame or smoke will be drawn into the draft hood If not the combustion products will tend to extinguish this flame If the combustion products are escaping from the relief opening of the draft hood IMMEDIATELY shutdown the boiler and contact a qualified service agency to make proper adjustments or repairs MG SG amp AAA Series Boilers User s Information Manual 12 BURNER SYSTEM To maintain safe and efficient operation examine the burner system regularly through the inspection hole near the pilot tube Check condition of burner system Over time it is possible for parts of the burners system to become plugged cracked eroded and or dislodged resulting in unsafe operation Pilot Flame The pilot flame should be adjusted to the point where the sensor rod is completely enveloped by the flame Figure 1 but Check ignition and extinction Ignition should flow
9. esence of soot or rust scale The draft hood and smoke pipe connecting the draft hood to the flue must be inspected for rust or corrosion before replacing the draft hood The presence of soot rust scale or corrosion indicates misadjustment Have a qualified service technician inspect the pilot burner and main burner The qualified service technician should follow the Maintenance Checklist and other applicable safety information found in the nstallation and Service Manual MG SG amp AAA Series Boilers User s Information Manual TYPICAL RESIDENTIAL BOILER COMPONENT LOCATIONS 18 ITEM DESCRIPTION 1 COMBINATION GAS VALVE 2 MANIFOLD ASSEMBLY 3 PILOT BURNER UNIT 4 IGNITION CONTROL MODULE 5 ZONE CONTROL BOARD TEMPERATURE PRESSURE GAUGE HI LIMIT SENSOR FLAME ROLL OUT SAFETY SWITCH BLOCKED VENT SAFETY SWITCH 10 AUTOMATIC VENT DAMPER 11 DRAFT HOOD TEMPERATURE PRESSURE GAUGE MOUNTED ON MODELS MG 125 MG 150 SG 225 AND SG 270 ONLY SUPPLIED LOOSE ON ALL OTHER MODELS BOILER INLET 9 OUTER CASING BOILER OUTLET WON IGNITER CABLE gt PILOT GAS LINE GAS NLET
10. f valve provides extra protection against damage that could be caused by malfunctioning controls or excessive water pressure If a pressure relief valve is not used the warranty is void The pressure relief valve must be installed by a qualified installer in accordance with local codes and should not be tampered with in any way The outlet of the pressure relief valve should be positioned over a suitable drain The drain pipe must pitch down from the pressure relief valve and should be no smaller than the outlet of the pressure relief valve The end of the drain line should not be concealed or threaded and should be protected from freezing No valve of any type should be installed between the pressure relief valve and unit or in the drain line Extensive runs traps or bends reduce the capacity of the pressure relief valve The pressure relief valve is a code requirement If discharge occurs during normal operation call a qualified service agency immediately Discharge indicates an unsafe pressure condition or a malfunctioning pressure relief valve Avoid contact with the hot water or steam discharged to prevent personal injury 15 BLOCKED VENT AND FLAME ROLL OUT SAFETY SWITCHES Applicable to all boilers with an input rating less than 300 000 BTU HR e This boiler is equipped with a Blocked Vent shut off system The safety switch will shut down the boiler should the vent or flue become partially or completely blocked Should this occur do not attem
11. functioning correctly The installer should always clearly identify the emergency shut off devices and make the owner aware of their location and method of operation 8 CHECK FOR GAS LEAKS To identify gas leaks smell for gas around boiler area and gas piping connections To check a specific area for leakage spray a mixture of soap and water onto the suspected area active bubbling indicates a gas leak DO NOT TEST FOR LEAKS WITH AN OPEN FLAME Propane or liquefied petroleum LP is heavier than air may collect or pool in a low area in the event of a leak from defective equipment This gas may then ignite resulting in a fire or explosion Smell near to the ground and low points when checking for propane gas leaks If you smell gas STOP Follow A in the safety instructions in Section 2 MG SG amp AAA Series Boilers User s Information Manual 9 CORROSIVE ATMOSPHERES If a gas boiler is to be installed near a corrosive or potentially corrosive air supply the boiler should be isolated from it and outside air should be supplied Chemical vapors from products containing chlorine or fluorine must be avoided Even though these chemicals may be safe to breathe corrosive substances can become liberated when passed through a gas flame Even at low concentrations these chemicals can significantly contaminate the air supply and shorten the life of any gas burning appliance The following is a list of some of the products which should be
12. jury exposure to hazardous materials or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier who must read and follow the supplied instructions before installing servicing or removing this boiler This product contains materials Refractory Ceramic Fibers that have been identified as carcinogenic or possibly carcinogenic to humans Follow the Refractory Handling Procedure instructions in the Installation and Service Manual WARNING It is the responsibility of the homeowner to keep the vent terminal and air supply terminal clear of snow and ice Use of Carbon Monoxide Detectors is recommended Follow building code requirements with respect to installation and approvals IN THE STATE OF MASSACHUSETTS ONLY For installations in the Commonwealth of Massachusetts the following local requirements apply in addition to all other applicable NFPA requirements For direct vent boilers mechanical vent heating appliances or domestic hot water equipment where the bottom of the vent terminal and the intake is installed below four feet above grade the following requirements must comply 1 If not present on each floor level where there are bedrooms a carbon monoxide detector and alarm must be placed a living area outside the bedrooms The carbon monoxide detector and alarm must comply with NFPA 720 Current Edition 2 Acarbon Monoxide detector and alarm shall be
13. l electrical power to the Boiler SHOWN IN ON POSITION 11 Set room thermostat to desired setting 12 If the appliance will not operate follow the 5 instructions To Turn Off Gas To Boiler in Section 7 and call your service technician or gas supplier To turn off gas to boiler or emergency shut off Follow Section 6 LIGHTING INSTRUCTIONS FOR INTERMITTENT ELECTRONIC IGNITION WITH NON COMBINATION GAS VALVE This boiler is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand Before turning on the electrical power switch be sure all gas supply lines are purged of air and power supply to control is the correct voltage If the pilot or main burners are not lit or the control system is locked out due to flame failure close the main and pilot gas shut off valves and call your service technician or gas supplier If you smell gas STOP Follow A in the safety instructions in Section 2 Check Control Operation controller Some controllers will retry ignition 1 STOP Read the safety instructions automatically after 5 minutes lockout Section 2 Start System 2 For 100 shut off check close main and pilot 1 manual gas shut off valves turn off all electric power to the boiler and wait for five minutes to 2 clear out any gas 3 Then smell for gas including near the floor If 3 you smell gas STOP Follow safety instructions in Section 2 If yo
14. located in the room that houses the appliance and or equipment and shall a Be powered by the same electrical circuit as the appliance and or equipment such that only one service switch services both the appliance and the carbon monoxide detector b Have battery back up power c Meet ANSI UL 2034 Standards and comply with NFPA 720 Current Edition and d Have been approved and listed by a Nationally Recognized Testing Lab as recognized under 527 CMR 3 product approved vent terminal must be used and if applicable a product approved air intake must be used Installation shall be performed in strict compliance with the manufacturer s instructions A copy of the installation instructions shall remain with the appliance and or equipment at the completion of the installation 4 metal or plastic identification plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight feet away and read Gas Vent Directly Below For direct vent boilers mechanical vent heating boilers or domestic hot water equipment where the bottom of the vent terminal and the intake is installed higher than four feet above grade the following requirements must comply 1 If not present on each floor level where there are bedrooms a carbon monoxide detector and alarm must be placed a living area outside the bedrooms The carbon
15. nes the operating and safety shut off into one valve body and is typical in residential installations A non combination gas valve system utilizes two separate valve bodies for operating and safety shut off and is typical in commercial installations If you are unsure which type of gas valve your boiler is equipped with check the lighting instructions sticker on the boiler or contact the factory MG SG amp AAA Series Boilers User s Information Manual 4 LIGHTING INSTRUCTIONS FOR INTERMITTENT ELECTRONIC IGNITION WITH COMBINATION GAS VALVE 1 This boiler is equipped with an ignition device NOTE On some gas valves the knob cannot which automatically lights the pilot Do not try be turned to OFF or ON position unless to light the pilot by hand Ensure gas supply knob is pushed in slightly Do not force to the boiler is turned on 7 Wait five 5 minutes to clear out any gas 2 STOP Read the safety instructions in Then smell for gas including near the floor Section 2 If you smell gas STOP Follow A in the 3 Set the room thermostat to lowest setting safety instructions in Section 2 If you don t 4 Turn off all electrical power to the appliance smell gas go to the next step 5 Remove control access panel if necessary 8 Turn gas control knob counterclockwise 6 Push in gas control knob slightly and turn 9 to ON clockwise to OFF 9 Replace control access panel if necessary GAS CONTROL KNOB 10 Turn on al
16. ot rust scale or corrosion Check for dislodged venting or possible leaks in venting ducts Visually inspect main burners and pilot to ensure proper flame operating characteristics and ignition extinction is ok Visually check burners to see that they are not cracked or dislodged Check that gas piping is secured Smell for gas leaks around boiler and gas piping connections Gas leaks can also be checked for using a soap solution do not use an open flame to check for leaks Note Propane is heavier than air and pools in low areas in the event of a leak Visually inspect for leaks in the water piping and at water piping connections Circulating pumps used with hot water heating systems should be inspected for water leaks Check for weeping at pressure relief valve outlet during normal operation Listen for unusual audible sounds in the boiler Read temperature and pressure gauge Check with qualified installer or service agency to determine acceptable temperature and pressure range for your heating system Combustible materials gasoline and other flammable vapors and liquids should not be stored in the area of the boiler If any problems are identified during your inspection contact a qualified service agency for corrective measures Once every year at the beginning of the heating season Have a qualified service technician remove the draft hood from the boiler and inspect the flueways for the pr
17. pt to re light the burner Contact a qualified service agency to ensure it is safe to re light the boiler e This boiler is equipped with a Flame Roll out shut off system The safety switch will shut down the boiler should flames roll out of the combustion chamber Should this occur do not attempt to re light the burner Contact a qualified service agency to ensure it is safe to re light the boiler 16 INSPECTION amp MAINTENANCE SCHEDULE This boiler has been designed to provide years of trouble free performance in normal installations The owner or user should conduct a general external examination covering all items on the User Checklist at the beginning of each heating season and in mid heating season to assure continued good performance In addition have the boiler inspected by qualified service technician or gas supplier s service person annually at the beginning of the heating season for continued safe operation Note that some operating conditions may require more frequent inspections MG SG amp AAA Series Boilers User s Information Manual 17 USER CHECKLIST Check air openings not restricted and will not be blocked off Adequate supply air is necessary for combustion flue gas dilution and ventilation When the boiler has operated for several minutes check for spillage at draft hood venting ducts and other areas susceptible to spillage Check externally the draft hood and vent system for so
18. u don t smell gas go to the next step 4 Set the thermostat above room temperature 4 and turn on all electric power to the boiler to energize the electronic ignition and pilot valve After a few seconds the control system should lockout and all functions are off 5 To take the control system out of lockout either press the reset button or interrupt power to the boiler depending on the boiler Turn on the main and pilot manual gas shut off valves Set thermostat above room temperature and turn on all electrical power to the boiler Once the pilot flame is proven the controller opens the main burner gas valves The pilot flame will ignite the gas as it exits the main burner ports Set thermostat to the desired setting to put system back in service Relight Operation Five minutes complete shut off period is required before attempting to relight the boiler To relight the boiler follow the Start System procedure above To turn off gas to boiler or emergency shut off Follow Section 6 MG SG amp AAA Series Boilers User s Information Manual 6 TOTURN OFF GAS TO THE BOILER OR EMERGENCY SHUT OFF WARNING Should boiler overheat or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the circulating pump Instead shut off the gas supply at a location external to the boiler 1 2 3 4 Set the thermostat to the lowest setting Turn all electrical po
19. udible sounds in the boiler system may be indications of scaling or lack of sufficient water flow and the system should be checked without delay Scaling is due to improper maintenance Itis not the fault of the boiler Scale damage is not covered by warranty In cold weather conditions take precautionary measures to ensure the system will maintain a minimum return temperature of 138 F Lower return temperatures will cause condensation on the heat exchanger or in the venting system and reduce draft suction In addition low temperatures in the system may result in extensive damage due to freezing if the system should shutdown possibly due to a safety switch shutdown for any length of time If freeze protection is required use an inhibited propylene glycol solution which is specifically designed for hydronic heating systems and always maintained at a neutral pH e g Fernox Alphi 11 or equivalent Follow the supplier s instructions for proper use and maintenance Do not use automotive antifreeze Some types of chemical additives can cause problems such as accelerated corrosion and result in premature failure of the boiler heat exchanger and or system components especially when not properly used or maintained Corrosion is a preventable condition and is not covered by warranty MG SG amp AAA Series Boilers User s Information Manual 14 PRESSURE RELIEF VALVE A pressure relief valve is supplied as standard equipment The pressure relie
20. using property damage personal injury or loss of life A BEFORE LIGHTING smell all around the B Use only your hand to push in or turn the gas boiler area for gas Be sure to smell next to control knob Never use tools If the knob will the floor because some gas is heavier than not push in or turn by hand don t try to repair air and will settle on the floor it call a qualified service technician Force or WHAT TO DO IF YOU SMELL GAS setae repair may result in a fire or e Do not try to light any appliance not touch any electrical switch do not C Do not use this boiler if any part has been use any phone in your building under water Immediately call a qualified e Immediately call your gas supplier from a service technician to inspect the appliance neighbor s phone Follow the gas and to replace any part of the control system supplier s instructions and any gas control which has been under e f you cannot reach your gas supplier water call the fire department 3 LIGHTING INSTRUCTIONS Your boiler is equipped with one of two optional electronic ignition systems Determine the ignition system that applies from the list below and go to the applicable lighting instruction section e Intermittent electronic ignition with combination gas valve for MG 50 E to SG 400 E Section 4 e intermittent electronic ignition with non combination gas valve for SG 450 E to AAA 3000 E 5 Note A combination gas valve combi
21. wer to the boiler off unless boiler is overheating see WARNING above Remove control access panel on the boiler if necessary For combination valve Push in gas control knob slightly and turn clockwise to OFF Do not force it For non combination valve Close the main and pilot manual gas shut off valves The valve is OFF when handle is perpendicular to the direction of gas flow 5 Replace control access panel if necessary If the boiler does not operate properly immediately contact a qualified service agency for adjustment or corrective measures 7 AREA AROUND BOILER WARNING Do not use this boiler if any part has been under water Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water Keep boiler area clear and free from combustible materials gasoline and other flammable vapors and liquids Do not store anything against the boiler or allow dirt or debris to accumulate in the area immediately surrounding the boiler It is unsafe for the flow of supply and exhaust air to be obstructed in any way Should your boiler be subjected to fire flood or some other unusual condition turn off all gas and electrical supply If you are unable to turn off the gas call your gas company or gas supplier at once Do not put the boiler in operation again until it has been ascertained by a qualified agency that the controls are