Sun Netra CP3x40 Switch Product Notes
Contents
1. Check the version of the ShMM firmware clia version b Check the midplane FRU clia fruinfo 20 1 grep FRU Programmer c Check the fantray FRU Fan Tray 1 clia fruinfo 20 3 v grep FRU Programmer Fan Tray 2 clia fruinfo 20 4 v grep FRU Programmer Fan Tray 3 clia fruinfo 20 5 v grep FRU Programmer 2 Perform a backup of the Netra CP3140 switch s default configuration The majority of the commands are mappable from the Netra CP3140 switch to the Netra CP3140 switch however there might be some that are not For Fabric ports the Netra CP3140 switch has 24 whereas the Netra CP3140 switch has 20 You might need to copy and paste the existing configuration from the Netra CP3140 switch into the Netra CP3140 switch Sun Netra CP3x40 Switch Product Notes e January 2010 3 Remove the Netra CP3140 switch and RTM Slot 8 is chosen first if the top ShMM is active Note Depending on the current ShMM deactivation settings the blue LED might not turn solid when unlatching the release lever as described in the following procedure For additional information on gracefully shutting down a node board please refer the Manual Graceful Shutdown of Node Boards section of the Sun Netra CT 900 Server Administration and Reference Manual 819 1177 a Unlatch the release lever then wait for the blue hotswap LED to turn solid b Remove the Netra CP3140 switch from the front c Re
2. Down Enable Enable short 11 Verify that links 1 and 17 cross connect are up for both ShMMs on Base switch console 12 Verify that link status from node blade is consistent with the value from the switch side as shown in the following examples CODE EXAMPLE 8 Example Link Status for Sun Netra CP3010 Board Solaris 10 OS uname a SunOS nsn97 23 5 10 Generic_118833 33 sun4u sparc SUNW Netra CP3010 ifconfig bge0 bge0 flags 1000843 lt UP BROADCAST RUNNING MULTICAST IPv4 gt mtu 1500 index 2 inet 10 7 97 23 netmask ffffff00 broadcast 10 7 97 255 ether 0 3 ba dc d0 89 kstat bge 0 grep speed ifspeed 1000000000 bus_speed fast link_speed 1000 Sun Netra CP3x40 Switch Product Notes 31 32 CODE EXAMPLE 9 Example Link Status for Sun Netra CP3020 Board MV Linux OS root nsn97 8 uname a Linux nsn97 8 2 6 10_mvlcge401 pc_target x86_amd64 1 SMP Tue Nov 14 14 11 35 PST 2006 x86_64 GNU Linux root nsn97 8 ifconfig eth2 eth2 Link encap Ethernet HWaddr 00 03 BA F1 D4 AA inet addr 10 7 97 75 Bcast 10 7 97 255 Mask 255 255 255 0 inet6 addr fe80 203 baff fef1l d4aa 64 Scope Link UP BROADCAST NOTRAILERS RUNNING MULTICAST MTU 1500 Metric 1 RX packets 34865 errors 0 dropped 0 overruns 0 frame 0 TX packets 10813 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 1000 RX bytes 2469356 2 3 MiB TX bytes 833164 813 6 KiB Interrupt 32 root nsn97 8 ethtool e
3. components are field recoverable if those are corrupted after a failed upgrade The IPMC firmware image is transferred in whole to the IPMC from the payload before IPMC over writes the firmware on board An interruption during this transfer does not corrupt the image on switch Although IPMC firmware ignores deactivation or reset reguests during the update of IPMC firmware it can still be corrupted by removing the switch from the chassis during the update With the introduction of failsafe upgrade for IPMC a Netra CP3140 switch will have a good backup image for IPMC to boot with An uninterrupted upgrade will recover the primary IPMC image in such a case The system image can get corrupted if there is an interruption when the configuration is copied to nvram startup config This situation is field recoverable Sun Netra CP3x40 Switch Product Notes e January 2010 Recovering Switch Firmware The following instructions and example describe how to recover the switch firmware if it is corrupted during an update To Recover Switch Firmware 1 If the switch is booting to the startup main menu but failing to boot the switch router application then choose option 2 at the main menu to go to the boot menu 2 Select option 7 to erase the permanent storage After the storage is erased the boot menu is displayed 3 Select option 2 to upgrade the switch firmware using TFTP The following code shows an example recovery CODE EXAMP
4. gt amp o Sun microsystems Sun Netra CP3x40 Switch Product Notes for the 1GbE and 10GbE Switches Sun Microsystems Inc www sun com Part No 820 3260 14 January 2010 Revision A Submit comments about this document at http www sun com hwdocs feedback Copyright 2010 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved This distribution may include materials developed by third parties Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Netra Sun Ray the Netra logo and the Solaris logo are trademarks or registered trademarks of Sun Microsystems Inc or its subsidiaries in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc Use of any spare or replacement CPUs is limited to repair or one for one root of CPUs in products exported in compliance with U S export laws Use of CPUs as product upgrades unless authorized by the U S Government is strictly prohibited DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTAT
5. nuclear maritime end uses or end users whether direct or indirect are strictly prohibited Export or reexport to countries subject to U S embargo or to entities identified on U S export exclusion lists including but not limited to the denied persons and specially designated nationals lists is strictly prohibited Upgrading Your Sun Netra CT 900 System If you are using the switches in a Sun Netra CT 900 server refer to the upgrade instructions in the following sources m Sun Netra CT 900 Server Upgrade Guide 820 3255 m Sun Netra CT 900 Product Notes 819 1180 m README files included in the release package Release packages are available from SDLC at sun com download Sun Netra CP3x40 Switch Product Notes e January 2010 Pairing Switches and RIMs Switches are paired with their RTMS When servicing switches and or RTMs take care in matching the correct RTM for the switch Each is labeled on the component Other methods for distinguishing the RTMS are as follows m 1GbE switch RTM has 18 RJ 45 connectors and no CX 4 connectors whereas the 10GbE switch RTM has 4 RJ 45 connectors and 6 CX4 or SFP connectors m 1GbE RTM is 2 inches wide whereas the 10GbE RTM connector is 3 inches wide m 1GbE switch has LED link indicators and no AMC slots m 10GbE switch has three AMC slots one of which can hold LED link indicators Caution Before inserting an RTM verify that RTM is the correct RTM for the switch in the front slot If you
6. the switch that you are upgrading You can configure the network using either the out of band management or the in band network If you are using the out of band management connect the MGMT port either through the front panel of the switch or through the rear transition card to the update network If you are using DHCP enter the following command serviceport protocol dhcp Caution If you are using DHCP for the serviceport then you must disable DHCP for the network by using the network protocol none command If you are using forced IP enter the following commands serviceport protocol none serviceport ip lt ipaddr gt lt subnet gt gateway Sun Netra CP3x40 Switch Product Notes 11 12 m If youare using the in band network connect any port of the network to your update network if you have the TFTP server on a node board then you can skip this step a If you are using DHCP enter the following command network protocol dhcp Caution If you are using DHCP for the serviceport then you must disable DHCP for the network by using the network protocol none command If you are using forced IP enter the following commands network protocol none network parms lt ipaddr gt lt subnet gt gateway 7 Download and install the updated firmware m If you are using serial telnet or SSH enter the following command to start the code update copy tftp lt yo
7. 0 Full U Up Enable Enable short 0 3 Enable Auto D Down Enable Enable short 0 4 Enable Auto D Down Enable Enable short 0 5 Enable Auto D Down Enable Enable short 0 6 Enable Auto D Down Enable Enable short 30 Sun Netra CP3x40 Switch Product Notes e January 2010 CODE EXAMPLE 7 Example for Verifying Port Status and Connection Speed Continued CP3240H BEX Z Base show port all 0 7 Enable Auto D Down Enable Enable short 0 8 Enable Auto D Down Enable Enable short 0 9 Enable Auto 1000 Full U Up Enable Enable short 0 10 Enable Auto 1000 Full U Up Enable Enable short 0 11 Enable Auto D Down Enable Enable short 0 12 Enable Auto D Down Enable Enable short 0 13 Enable Auto D Down Enable Enable short 0 14 Enable Auto D Down Enable Enable short 0 15 Enable Auto D Down Enable Enable short 0 16 Enable Auto D Down Enable Enable short 0 17 Enable Auto Down Enable Enable short 0 18 Enable Auto Down Enable Enable short More or q uit Admin Physical Physical Link Link LACP Actor Intf Type Mode Mode Status Status Trap Mode Timeout 0 19 Enable Auto Down Enable Enable short 0 20 Enable Auto Down Enable Enable short 0 21 Enable Auto 1000 Full Up Enable Enable short 0 22 Enable Auto Down Enable Enable short 0 23 Enable Auto Down Enable Enable short 0 24 Enable Auto Down Enable Enable short 0 25 Enable Auto 10G Full Up Enable Enable short 0 26 Enable Auto Down Enable Enable short 0 27 Enable Auto
8. 5 BO attached as unit 0 NPCI device BCM5695 BO attached as unit 1 Switch Router Started Unit 1 gt User Your switch is recovered However you ll have to reapply your configuration V To Recover the OS or Root File System If the switch is not booting to the main menu level then the Linux OS image or the root file system image might be corrupted recover them from the Uboot level 1 Extract the following files from the bundle and make them TFTP server accessible mu ulmage m rootfs cramfs 2 Go to the Uboot prompt gt 3 Set up Ethernet parameters as in the following example Replace the sample IP addresses with your IP addresses DHCP gt mw b 400000 ff 300000 dhcp set serverip 10 10 3 199 Static gt mw b 400000 ff 300000 gt set serverip 10 10 2 9 gt set ipaddr 10 10 2 71 gt set netmask 255 255 254 0 gt set gatewayip 10 10 2 1 Sun Netra CP3x40 Switch Product Notes 21 22 4 Recover the Linux kernel as in the following example Replace the sample path with your path gt tftp 400000 test cp3240 uImage gt erase fff60000 ffffffff cp b 400000 ff60000 a0000 cmp b 400000 f 60000 a0000 5 Recover the Root Filesystem as in the following example Replace the sample path with your path gt tftp 400000 test cp3240 rootfs cramfs gt erase ffc00000 ffefffff cp b 400000 ffc00000 300000 cmp b 400000 fc00000 300000 6 Reboo
9. 55 vlan tagging 55 vlan ingres exit interface vlan accept vlan partic sfilter 0 16 frame all ipation include 55 vlan tagging 55 vlan ingres exit interface vlan accept sfilter 0 17 frame all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 18 vlan ingressfilter exit interface 0 19 vlan ingressfilter exit interface 0 20 vlan ingressfilter exit interface 0 21 vlan ingressfilter exit interface 0 22 vlan ingressfilter exit interface 0 23 vlan ingressfilter exit interface 0 24 vlan ingressfilter exit interface 0 25 vlan ingressfilter exit interface 0 26 vlan ingressfilter Sun Netra CP3x40 Switch Product Notes 35 36 CODE EXAMPLE 10 Script for Configuring NetConsole VLAN55 Support Continued vlan database exit interface 0 27 vlan ingressfilter exit exit 2 Save the script file containing the Sun NetConsole configuration Example CP3240 Base SUN Netconsole scr 3 Place the script file on the TFTP server 4 Login to the switch and enter into user privilege mode enable 5 Configure the network parameters of the switch This configuration is reguired for connectivity between the switch and the TFIP server a Check the current configuration CP3240H BEX Z Base show network IP Address A ee epika eee ee 0 0 0 0 Subnet MASK in KiNG tas Wan ne SNE
10. CP3240H RTM CUZ 9 Verify the switch software version on the switch console as shown in the following example CODE EXAMPLE 6 Example for Verifying Switch Software Version CP3240H BEX Z Base show hardware Switch 1 System Description CP3240H BEX Z Base Machine Types riea eue ue date Me De tan Broadcom FIREBOLT 56504 Development System 24 FE 4 TENGIG Machine Model ss ik at ne reine BCM 56504 serial Number cs snc wis ke aaa Bie ed gens ne ds 1544DTI 0732330000 FRU NUDBE ides i pas Ba dee Bes Saas te eee a Part Number z asas Ee ek twee A due A e BCM956504 Maintenance Leve midi ita ees A ManufacUUrO aia Wan siens ete de as Oxbc00 Burned In MAC Address 00 20 13 F1 07 ED Software Version ce scesa ad ee a a aaa 1 1 4 0 Operating SYSTEM usa o der BE bee ue Linux 2 4 20 mvl31 Network Processing Device BCM56504 REV 1 Additional Packages FASTPATH QOS FASTPATH Multicast FASTPATH IPv6 10 Verify the port status and connection speed negotiation on the switch console for both Base and Fabric as shown in the following example CODE EXAMPLE 7 Example for Verifying Port Status and Connection Speed CP3240H BEX Z Base 4 show port all Admin Physical Physical Link Link LACP Actor Intf Type Mode Mode Status Status Trap Mode Timeout 0 1 Enable Auto 100 Full U Up Enable Enable short 0 2 Enable Auto 100
11. IONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2010 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Cette distribution peut comprendre des composants d velopp s par des tierces parties Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Netra Sun Ray le logo Netra et le logo Solaris sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc ou ses filiales aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L utilisation de pieces detachees ou d unites centrales de remplacement est limitee aux reparations ou a l echange standard d unites centrales pour les produits exportes conformement a la legislation americaine en matiere d exportation Sauf autorisation par les autorites de
12. L to all processes Please stand by while rebooting the system CPUs 400 MHz DRAM 128 MB FLASH 32 MB Press any key here gt This indicates you are at uboot prompt Sun Netra CP3x40 Switch Product Notes 23 V To Disable eKeying for a Port From Uboot 1 Reboot the switch to Uboot prompt gt 2 Enter the following command seguence gt set noekey 2 gt save gt boot Reguired One Time Binary Update for R2 0 1 If your system is already upgraded to R2 0 1 or newer the following reguirement does not apply However if you are using an earlier version and want to upgrade you must perform a one time reguired configuration procedure The procedure configures the switch Base and Fabric with the pre configured binary For R2 0 1 the pre configured binary is named cp3140 base sun r2 0 1 cfg Sun s configuration sets up a VLAN ID 55 that includes ports 1 and 3 to 17 for the NetConsole application to use in the Base and Fabric ports The purpose of this VLAN is to contain NetConsole traffic within the chassis The following are reguired to complete the configuration procedure m Update the console access to the Netra CP3140 switch m Access a TFIP server from the switch preferably in the same network For instructions on how to perform the reguired configuration refer to the README SWITCH_CFG file included with the ATCA download package on SDLC vlan Command Range In the Sun Netra CT 900 Serve
13. LE 4 Example Recovering the Switch Firmware Booting CP3140H BEG Boot Menu v1 1 Select startup mode If no selection is made within 5 seconds the Switch Router Application will start automatically Switch Router Startup Main Menu 1 Start Switch Router Application 2 Display Utility Menu Select 1 2 2 CP3140H BEG Boot Menu v1 1 Switch Router Startup Utility Menu Start Switch Router Application Load Code Update Package using TFTP Display Vital Product Data Select Serial Speed Retrieve Error Log using TFTP Erase Current Configuration Erase Permanent Storage Select Boot Method BCM Debug Shell 10 Reboot Select option 1 10 7 Do you want to erase the permanent storage Press Y N y Unmounting filesystem done Erased 12160 Kibyte 0 100 complete Mounting filesystem done CP3140H BEG Boot Menu v1 1 CO lt a WU amp NE vo Sun Netra CP3x40 Switch Product Notes 19 CODE EXAMPLE 4 Example Recovering the Switch Firmware Continued Booting Switch Router Startup Utility Menu 1 Start Switch Router Application 2 Load Code Update Package using TFTP 3 Display Vital Product Data 4 Select Serial Speed 5 Retrieve Error Log using TFTP 6 Erase Current Configuration 7 Erase Permanent Storage 8 Select Boot Method vo BCM Debug Shell 10 Reboot Select option 1 10 2 Creating tmpfs filesystem on tmpfs for dow
14. atchdog is not disabled using E4 jumper before an upgrade Disabling the IPMI watchdog is NOT required for an upgrade from 1 6 0 0 or 1 7 1 0 to 1 8 X 0 level However make sure the IPMC version is 1 3 2 or newer 1 Disable IPMI watchdog before upgrading a switch with 1 5 0 0 or earlier firmware IPMC 1 3 0 or earlier to 1 7 1 0 level 2 Remove the switch card from the chassis to set the jumper 3 Set the E4 jumper to 1 2 to disable the IPMI watchdog reset The F4 jumper is located in the top left of the switch card when held vertically with latches on the left side 4 After the upgrade is done enable the IPMI Watchdog by removing the jumper from E4 4 Sun Netra CP3x40 Switch Product Notes e January 2010 V To Test Updates Before Installing Them The switch supports network booting This feature can be used to test updates to FASTPATH without installing them Updates containing changes to U Boot Linux or the IPMC must be installed to the flash before they can be used 1 2 Set up a TFTP server on the update network Place the update image on the TFTP server Connect to the serial management port of the network to be updated and connect the MGMT port or out of band network management port to the update network Reset the switch Following are the different methods that you can use to reset the switch Press the reset button on the switch Disengage and reengage the card injector ejector mechanisms at t
15. ate for R2 0 1 24 vlan Command Range 24 Latch Over Rotates 25 Sun Netra CP3240 Switches 26 Enhancements 26 Fiber Optic RTM 27 Documentation for the Sun Netra CP3240 Switches 27 Replacing Sun Netra CP3140 Switches With Sun Netra CP3240 Switches 28 v To Replace a Sun Netra CP3140 Switch 28 Configuring NetConsole VLAN55 Support 33 AMC Sites on the Sun Netra CP3240 Switch 39 Sun Netra CP3x40 Switch Product Notes e January 2010 Sun Netra CP3x40 Switch Product Notes The Sun Netra CP3x40 Switch Product Notes contain important and late breaking information about the Sun Netra CP3140 and Sun Netra CP3240 switches This document includes instructions for upgrading from earlier releases This document contains the following m General on page 2 m Sun Netra CP3140 Switches on page 15 m Sun Netra CP3240 Switches on page 26 Note For additional information refer to the README files included in the software and firmware packages General The following sections apply to both the Netra CP3140 switch and the Netra CP3140 switch m Additional Copyright Information on page 2 m Upgrading Your Sun Netra CT 900 System on page 2 m Upgrading the Switch Firmware on page 3 Additional Copyright Information This product is covered and controlled by U S Export Control laws and may be subject to the export or import laws in other countries Nuclear missile chemical biological weapons or
16. ce 0 6 lan acceptframe all lan participation include 55 lan tagging 55 lan ingressfilter exit eS Dea oO lt b Bae oe Sea O E ae a NE U Sun Netra CP3x40 Switch Product Notes CODE EXAMPLE 10 Script for Configuring NetConsole VLAN55 Support Continued vlan database interface 0 7 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 8 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 9 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 10 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 11 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 12 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 13 vlan acceptframe all vlan participation include 55 vlan tagging 55 vlan ingressfilter exit interface 0 14 vlan acceptframe all vlan participation include 55 vlan tagging 55 34 Sun Netra CP3x40 Switch Product Notes e January 2010 CODE EXAMPLE 10 Script for Configuring NetConsole VLAN55 Support Continued vlan database vlan ingres exit interface vlan accept vlan partic sfilter 0 15 frame all ipation include
17. de ae indus 0 0 0 0 Default Gateway sesa se eb se ee seen ee ses 0 0 0 0 Burned In MAC Address 00 20 13 F1 07 ED Locally Administered MAC Address 00 00 00 00 00 00 MAC Address THD Geo ar usuels een dae oo cee dre ainia Burned In Network Configuration Protocol Current None Management VLAN ID 1 b Set the in band network interface by using the network parms lt ip address gt lt netmask gt lt gateway ip address gt command as in the following example CP3240H BEX Z Base network parms 10 7 97 90 255 255 255 0 10 7 97 254 c Confirm the configuration by using the show network command CP3240H BEX Z Base show network IP Address Ai kidd a ee dt 10 7 97 90 Subnet MASK hisser a enter pan 255 255 255 0 Default Gateway si runs naine rate Gin Saw ate dt dci kla 10 7 97 254 Burned In MAC Address 00 20 13 F1 07 ED Locally Administered MAC Address 00 00 00 00 00 00 Sun Netra CP3x40 Switch Product Notes e January 2010 MAC Address T pe 2 A aa Burned In Network Configuration Protocol Current None Management VLAN ID 1 d Check the configuration by pinging the TFTP server IP address from the switch CP3240H BEX Z Base ping 10 7 97 142 6 Copy the configuration from TFTP server CP3240H BEX Z Base copy t t
18. e Reference Manual 820 3253 26 Sun Netra CP3x40 Switch Product Notes e January 2010 Fiber Optic RTM A fiber optic RTM XCP3240H RTM OP Z is available for use with the Sun Netra CP3240 switch For information see the Sun Netra CP3240 Switch Installation Guide 820 3251 Documentation for the Sun Netra CP3240 Switches The following documentation provides detailed information and instructions for installing using and configuring the Netra CP3140 switches m Sun Netra CP3240 Switch Installation Guide 820 3251 m Sun Netra CP3240 Switch User s Guide 820 3252 m Sun Netra CP3240 Switch Software Reference Manual 820 3253 All of these documents are available online at http docs sun com app docs prod cp3240 switch l en hic Sun Netra CP3x40 Switch Product Notes 27 28 Replacing Sun Netra CP3140 Switches With Sun Netra CP3240 Switches This section describes the procedure for hot swapping the Netra CP3140 switches into a Sun Netra CT 900 chassis containing Netra CP3140 switches CP3140 switches If you are upgrading an older 1GbE chassis Netra CT 900 server you must upgrade the fan trays to provide adeguate cooling For more information refer to the Sun Netra CT 900 Server Upgrade Guide 820 3255 A Caution The Sun Netra CP3240 switches require higher speed fans than the Netra V To Replace a Sun Netra CP3140 Switch 1 On the active ShMM verify that the chassis firmware FRU images are up to date a
19. force an incorrect RTM into the rear slot damage will occur to the RTM pins and possibly to the switch Upgrading the Switch Firmware Release packages are available from SDLC at sun com download Following is the list of firmware that is on the switch a IPMC firmware m Base firmware a Base U Boot loader Base Linux operating system Base FASTPATH application m Fabric firmware a Fabric U Boot boot loader Fabric Linux operating system Fabric FASTPATH application All of the firmware listed are field upgradable There is a single update image that supports the Base firmware Fabric firmware and IPMC firmware This update image must be installed twice for each switch once on the Base and once on the Fabric The IPMC update happens during a Base update Linux and FASTPATH can be booted over the network Caution Do not use rmcpUpgrade utility released in R2 0 for stand alone upgrade of the Sun Netra CP3140 IPMC firmware Sun Netra CP3x40 Switch Product Notes 3 V To Determine IPMC Firmware Version Login to ShMM and run the following command clia board v lt switch slot number gt grep ver Device ID 0x00 Revision 1 Firmware 1 41 IPMI ver 1 5 V To Upgrade a Switch From Version 1 5 0 0 or Earlier from 1 5 0 0 to 1 7 1 0 the IPMC firmware on the Sun Netra CP3140 switch might get corrupted A Sun Netra CP3140 switch with corrupted firmware is not recoverable in the field A Caution If IPMI W
20. fully base reload Sun Netra CP3x40 Switch Product Notes e January 2010 Sun Netra CP3140 Switches The following sections apply only to the Netra CP3140 switches m Enhancements on page 15 mu Documentation for the Sun Netra CP3140 Switches on page 16 m Enabling Cross Connect Links on page 16 Port Shutdown Behavior on page 17 m Reliable Firmware Upgrade on page 17 m Upgrade Vulnerabilities and Field Recovery on page 18 m Recovering Switch Firmware on page 19 m Required One Time Binary Update for R2 0 1 on page 24 m vlan Command Range on page 24 m Latch Over Rotates on page 25 Enhancements The Sun Netra CP3140 switch firmware was enhanced to enable an external application or system to control the Layer 2 fail over from one Sun Netra CP3140 switch to another in the same Sun Netra CT 900 chassis This solution decreases up link fail over intervals to less than a second by using redundant switches Included with the L2 failover feature is an enhancement for link aggregation LAG A port channel can be used as the tracked link and or as the port to be forced into the link down state as the result of a track signaling a fault The following commands were added or enhanced m track interface 0 line protocol min tracks that a minimum number of links in a portchannel are up m show track lt all gt provides enhanced output a show track failover
21. he top and bottom of the card Execute the reload command through the switch software As the switch resets press 2 to enter the Utility Menu Press 8 to change the boot method Press 3 to select network as the boot method Enter the necessary information for your TFTP server For the host IP field you can enter dhcp if you would like to use DHCP to obtain a valid IP address Press 1 to boot the system Use option 8 of the Utility Menu to change the boot method back to flash if necessary Following is an example of the console output note that there might be slight variations depending on the settings and the software versions CODE EXAMPLE 1 Sample Output for Network Booting CPU 400 MHz DRAM 128 MB FLASH 32 MB Booting Boot Menu v1 0 Sun Netra CP3x40 Switch Product Notes 5 6 CODE EXAMPLE 1 Sample Output for Network Booting Continued Switch Router Startup Main Menu 1 Start Switch Router Application 2 Display Utility Menu Select 1 2 2 Boot Menu v1 0 Switch Router Startup Utility Menu 1 Start Switch Router Application 2 Load Code Update Package using TFTP 3 Display Vital Product Data 4 Select Serial Speed 5 Retrieve Error Log using TFTP 6 Erase Current Configuration 7 Erase Permanent Storage 8 Select Boot Method 9 BCM Debug Shell 10 Reboot Select option 1 10 8 Current boot method FLASH 1 Flash Boot 2 Network Boot 3 Ex
22. ion Saved AMC Sites on the Sun Netra CP3240 Switch The following table lists available AMC sites on the CP3240 and how they map to the IPMB L address TABLE3 AMC Sites on the Sun Netra CP3240 Switch Physical Site AMC Slot ID IPMB L Address 1 top 5 0x7 A 2 middle 6 0x7C 3 bottom 7 0x7E For more information refer to the AMC documentation Sun Netra CP3x40 Switch Product Notes 39 40 Sun Netra CP3x40 Switch Product Notes e January 2010
23. it without change Select option 1 3 2 Enter Server IP 10 10 3 199 Enter Host IP dhcp Enter Gateway IP Enter Filename p CP3140 1 4 1 1 tgz Accept changes Press Y N y Boot Menu v1 0 Switch Router Startup Utility Menu Start Switch Router Application Load Code Update Package using TFTP Display Vital Product Data Select Serial Speed Retrieve Error Log using TFTP Erase Current Configuration DAU amp amp NH Select startup mode If no selection is made within 5 seconds the Switch Router Application will start automatically Sun Netra CP3x40 Switch Product Notes e January 2010 CODE EXAMPLE 1 Sample Output for Network Booting Continued 7 Erase Permanent Storage 8 Select Boot Method 9 BCM Debug Shell 10 Reboot Select option 1 10 1 Creating tmpfs filesystem on tmpfs for download done Bringing up eth0 interface done Transferring p CP3140 1 4 1 1 tgz from 10 10 3 199 done Bringing down eth0 interface done Copying Application to RAM done Destroying tmpfs filesystem on tmpfs done Starting Application 1 File bootos c Line 244 Task 111cb214 EC 2863311530 Oxaaaaaaaa 0 d 0 hrs 1 min 8 sec Switch Router Starting PCI device BCM5695 BO attached as unit 0 PCI device BCM5695 BO attached as unit 1 Switch Router Started Unit 1 gt User Sun Netra CP3x40 Switch Product Notes 7 V To Upgrade the S
24. l All of these documents are available online at http docs sun com app docs prod n900 srvr hic Enabling Cross Connect Links If the cross connect links port 17 are not up on your switch it is most likely due to an incorrect setting of the El jumper Set the E 1 jumper on the Sun Netra CP3140 to enable 1 2 to allow cross connect links to the ShMM 16 Sun Netra CP3x40 Switch Product Notes January 2010 Port Shutdown Behavior There is a difference in port shutdown behavior between the Base and Fabric interfaces The Fabric ports are physically shutdown which means that when a Fabric port is shutdown the other side does not show a link In contrast Base ports are only logically shutdown which means that when a port is shutdown the other side shows a link These behaviors are not a problem but rather a difference in the Fabric and base interfaces The Fabric ports are a different type of Ethernet than Base ports Base ports need external PHYs to support 1000Base T Fabric ports do not need external PHYs because the BCM5695 can support 1000Base BX directly When a shutdown command is issued on both the Base and Fabric the command goes to the BCM5695 Because the BCM5695 connects directly to the backplane in the case of the Fabric the link goes down In the case of the Base even when the BCM5695 port is shutdown the BCM5464R port is not shut down so the link partner still sees a link Reliable Firmware Upgrade The fla
25. lt all gt provides enhanced output m auto negotiate lt master slave gt forces 1000Base T ports into a different auto negotiation mode Because slave ports detect link down more guickly than master ports uplink ports can be put into slave mode Downlink ports can be put into master mode Sun Netra CP3x40 Switch Product Notes 15 Revised documentation describes how to implement the Layer 2 fail over after you upgrade your firmware New switch configuration commands failover track and show track failover are provided For more information and examples of configurations refer to the README file For detailed instructions on how to use the fail over commands refer Switching Commands in the Sun Netra CP3140 Switch Software Reference Manual 819 3774 Additionally a document titled Designing a Fault Tolerant Network Using Sun Netra CP3x40 Switches 820 7346 provides information and examples for designing a fault tolerant network using redundant switches Documentation for the Sun Netra CP3140 Switches The following documentation provides detailed information and instructions for installing using and configuring the Netra CP3140 switches m Netra CT 900 Server Overview 819 1174 m Netra CT 900 Server Installation Guide 819 1175 m Netra CT 900 Server Administration and Reference Manual 819 1177 m Sun Netra CP3140 Switch Software Reference Manual 819 3774 Formerly the Netra CT 900 Server Switch Software Reference Manua
26. mmand forms For the syntax of a particular command form please consult the documentation Base gt enable Password CP3140 Base network protocol none Changing protocol mode will reset ip configuration Are you sure you want to continue y n y Base serviceport protocol dhcp Changing protocol mode will reset ip configuration Are you sure you want to continue y n y Sun Netra CP3x40 Switch Product Notes 13 14 CODE EXAMPLE 3 Example Output for Upgrading the Firmware Through the FASTPATH Software Continued Base show serviceport IP Address poi et ie ea A ro a a 10 10 3 3 Subnet MASK get Re a aa ka nan EN sh eae 255 255 254 0 Default Gateway 10 10 2 1 ServPort Configured Protocol Current DHCP Burned In MAC Address 00 20 13 F0 BB E8 Base copy tftp 10 10 3 199 p CP3140 1 4 1 1 tgz system image MOGE sus A a tare Rea a Bale DAR ee Eee Bes TFTP Set TETP Server IPs unten ia 10 10 3 199 TEPP Pahana tees Ree a lane Ore tetje Pie e hos p TETP_Fil nam ss eke eae we en lek Regie dco a CP3140 1 4 1 1 tgz Data Typs cesera oy eee ele este SESE DSS ns Code Are you sure you want to start y n y TFTP Code transfer starting Updating components Please wait Extracting components Checking Vital Product Data Updating Switch Router Application Done File transfer operation completed success
27. move the Netra CP3140 switch RTM from the rear 4 Insert the new RTM for the Netra CP3140 switch in the rear 5 Insert the Netra CP3140 switch in the front 6 Wait for the switch to boot up When the green OK LED is on the new switch is up 7 Verify that the Netra CP3140 switch is functioning properly and that connectivity is not interrupted Note NetConsole will be interrupted when the switch in slot 7 is removed See Configuring NetConsole VLAN55 Support on page 33 for configuration instructions 8 Verify that the switch is detected on the ShMM as shown in the following example CODE EXAMPLE 5 Example for Verifying New Switch Detection on ShMM clia board 8 Pigeon Point Shelf Manager Command Line Interpreter Physical Slot 8 84 Entity 0xa0 0x60 Maximum FRU device ID 0x04 PICMG Version 2 2 Hot Swap State M4 Active Previous M3 Activation In Process Last State Change Cause Normal State Change 0x0 84 FRU 0 Entity 0xa0 0x60 Hot Swap State M4 Active Previous M3 Activation In Process Last State Change Cause Normal State Change 0x0 Device ID String CP3240H BEX Z Sun Netra CP3x40 Switch Product Notes 29 CODE EXAMPLE 5 Example for Verifying New Switch Detection on ShMM Continued 4 clia board 8 84 FRU 1 Entity 0xc0 0x60 Hot Swap State M4 Active Previous M3 Activation In Process Last State Change Cause Normal State Change 0x0 Device ID String X
28. n page 27 m Replacing Sun Netra CP3140 Switches With Sun Netra CP3240 Switches on page 28 m Configuring NetConsole VLAN55 Support on page 33 Enhancements The L2 failover feature is enhanced in the R3U3 release to include link aggregation LAG pre emphasis control and enhanced output for show track commands A port channel can be used as the tracked link and or as the port to be forced into the link down state as the result of a track signaling a fault The following commands were added or enhanced m track interface 0 line protocol min tracks that a minimum number of links in a portchannel are up m show track lt all gt provides enhanced output a show track failover lt all gt provides enhanced output m auto negotiate lt master slave gt forces 1000Base T ports into a different auto negotiation mode Because slave ports detect link down more guickly than master ports uplink ports can be put into slave mode Downlink ports can be put into master mode A pre emphasis interface configuration command is now available Pre emphasis compensates 10G CX4 interfaces for varying cable lengths The following new command is available only at interface level pre emphasis level lt 1 15 gt Default value is 10 For more information and examples of configurations refer to the README file For detailed instructions on how to use these commands refer Switching Commands in the Sun Netra CP3240 Switch Softwar
29. nload done Enter Server IP 10 4 77 241 Enter Host IP 10 4 77 79 Enter Gateway IP 10 4 77 1 Enter Filename imangs 0 t Do you want to continue Press Y N y Bringing up eth0 interface done Adding default gateway 10 4 77 1 to the Routing Table done Transferring 1 7 1 0 tgz from 10 4 77 241 done Bringing down eth0 interface done Running update script Updating components Please wait Checking Vital Product Data Updating Switch Router Application Detecting IPMC Switching from 38400 to 38400 baud Extracting IPMC Firmware IPMC Firmware Matches Skipping Update Updating Operating System Operating System Matches Skipping Update Updating File System File System Matches Skipping Update Destroying tmpfs filesystem on tmpfs done CP3140H BEG Boot Menu v1 1 Switch Router Startup Utility Menu Start Switch Router Application Load Code Update Package using TFTP Display Vital Product Data Select Serial Speed Retrieve Error Log using TFTP Erase Current Configuration Erase Permanent Storage Select Boot Method BCM Debug Shell LO O I O UN BUN pp 20 Sun Netra CP3x40 Switch Product Notes e January 2010 CODE EXAMPLE 4 Example Recovering the Switch Firmware Continued Booting 10 Reboot Select option 1 10 1 Copying Application to RAM done Starting Application Switch Router Starting PCI device BCM569
30. p lt ipaddress gt gt lt filepath gt lt fileName gt nvram script lt scriptName gt For example CP3240H BEX Z Base copy tftp 10 7 97 142 CP3240 Base SUN Netconsole scr nvram script CP3240 Base SUN Netconsole scr MOGE nh A A Re ES ee eS TFTP Set TETP Server IP sue silent Waele el a Raed lens et 10 7 97 142 TETP Palla A EN RE ds oh TETP Filename A A A PO CP3240 Base SUN Netconsole scr Data Types nent nome ee LONE BAB o BAe dee Config Script Destination Filename CP3240 Base SUN Netconsole scr Management access will be blocked for the duration of the transfer Are you sure you want to start y n y Validating configuration script Configuration script validated File transfer operation completed successfully 7 If you want verify that the script exists by using the script list command as in the following example CP3240H BEX Z Base script list Configuration Script Name Size Bytes CP3240 Base SUN Netconsole scr 2446 kc scr 1058 2 configuration script s found 2044 Kbytes free Sun Netra CP3x40 Switch Product Notes 37 38 8 Apply the configuration script using the script apply lt scriptName gt command as shown in the following example CODE EXAMPLE 11 Applying the NetConsole Script P3240H BEX Z Base script apply CP3240 Base SUN Netconsole scr Are you sure you want to apply the configuration script y n y Would
31. r Switch Software Reference Manual 819 3774 11 the acceptable range for the VLAN identification number is incorrectly stated as 2 4094 The correct range is 2 4021 The content will be revised with the next release of the document The following is the revised range and content vlan This command creates a new VLAN and assigns it an ID The ID is a valid VLAN identification number ID 1 is reserved for the default VLAN VLAN range is 2 4021 24 Sun Netra CP3x40 Switch Product Notes e January 2010 Latch Over Rotates When installing a Netra CP3140 switch into the Sun Netra CT 900 server it is possible to over rotate the upper injector ejector latch mechanism on the board which would not allow you to insert the switch board into the server properly FIGURE 1 shows the proper orientation for the board injector ejector when you are installing a switch board into the Sun Netra CT 900 server Keep in mind that even though the figure shows the lower injector ejector mechanism this problem affects only the upper injector ejector mechanism on the switch board FIGURE 1 lnjector Ejector on the Switch Open Position A y Le Card injector ejector mechanism Sun Netra CP3x40 Switch Product Notes 25 Sun Netra CP3240 Switches The following sections apply only to the Netra CP3140 switches u Enhancements on page 26 m Fiber Optic RTM on page 27 m Documentation for the Sun Netra CP3240 Switches o
32. s Etats nis l utilisation d unites centrales pour proceder a des mises a jour de produits est rigoureusement interdite LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON ES Esa CA Adobe PostScript ES Esa CA Adobe PostScript Contents Sun Netra CP3x40 Switch Product Notes 1 General 2 Additional Copyright Information 2 Upgrading Your Sun Netra CT 900 System 2 Pairing Switches and RTMs 3 Upgrading the Switch Firmware 3 To Determine IPMC Firmware Version 4 To Upgrade a Switch From Version 1 5 0 0 or Earlier 4 To Test Updates Before Installing Them 5 asa lt To Upgrade the Switch Firmware Through the Boot Utility Menu 8 v To Upgrade the Switch Firmware Through the FASTPATH Software 11 Sun Netra CP3140 Switches 15 Enhancements 15 Documentation for the Sun Netra CP3140 Switches 16 Enabling Cross Connect Links 16 Port Shutdown Behavior 17 Reliable Firmware Upgrade 17 Upgrade Vulnerabilities and Field Recovery 18 Recovering Switch Firmware 19 vi v To Recover Switch Firmware 19 v To Recover the OS or Root File System 21 v To Boot to the Uboot Prompt 23 To Disable eKeying for a Port From Uboot 24 Reguired One Time Binary Upd
33. sh upgrade tool is enhanced to provide a reliable upgrade in the event that an upgrade is interrupted or corrupted Now using this upgrade administrative users can manage user accounts in a centralized way For detailed information about how to configure and use this upgrade refer to the Netra CT 900 Server Administration and Reference Manual 819 1177 Caution Do not use rmcpUpgrade utility released in R2 0 for stand alone upgrade of the Sun Netra CP3140 IPMC firmware Sun Netra CP3x40 Switch Product Notes 17 18 Upgrade Vulnerabilities and Field Recovery If an on board upgrade of switch firmware bundle is interrupted terminated by a reset or power cycle of the payload or IPMC or by removing the board from the chassis the following components on the switch might get corrupted depending when the interruption occurs during the upgrade TABLE1 Field Recoverable Components Component Field recoverable Uboot No Linux OS Yes Root file system Yes Application and configuration Yes IPMC firmware yes from firmware version 1 8 X 0 Interrupting the transfer of the bundle over the network uses TFTP does not cause any corruption The whole bundle is transferred to the switch before the upgrade is started Starting with version 1 7 1 0 the Uboot image has been removed from the bundle therefore Uboot will not be upgraded With the introduction of field recoverability of the IPMC firmware in version 1 8 X 0 all
34. stroying tmpfs filesystem on tmpfs done Boot Menu v1 0 Switch Router Startup Utility Menu Start Switch Router Application Load Code Update Package using TFTP Display Vital Product Data Select Serial Speed Retrieve Error Log using TFTP Erase Current Configuration Erase Permanent Storage Select Boot Method BCM Debug Shell Reboot H 10 OO I AU BWNE o Select option 1 10 10 Rebooting syncing filesystems This may take a few moments umount forced umount of null failed Rebooting system The system is going down NOW Sending SIGKILL to all processes Please stand by while rebooting the system Sun Netra CP3x40 Switch Product Notes e January 2010 V To Upgrade the Switch Firmware Through the FASTPATH Software These instructions cover all firmware updates initiated through the FASTPATH software 1 2 Set up a TFTP server on the update network Place the update image on the TFTP server Determine if you are using telnet SSH or SNMP If you are using telnet SSH or SNMP skip to Step 7 If you are not using telnet SSH or SNMP then continue with Step 4 Connect to the serial management port of the network to be updated The Netra CP3140 switch has two external console ports one for 3 0 and 3 1 The Sun Netra CP3240 switch has a single external console port Log in to the switch and enter into user privilege mode enable Configure the network of
35. t the switch by using the reset command gt reset Your switch is now recovered However you will have to reapply your configuration Sun Netra CP3x40 Switch Product Notes e January 2010 V To Boot to the Uboot Prompt Use the following example to boot to the Uboot prompt TABLE2 Example Boot to the Uboot Prompt CP3140H BEG Base reload The system has unsaved changes Would you like to save them now y n n Configuration Not Saved Are you sure you would like to reset the system y n y System will now restart The Switch Driver has been reset at the request of the user usmdb_sim c 1205 Reference platform resetting CP3140H BEG Boot Menu v1 0 Select startup mode If no selection is made within 5 seconds the Switch Router Application will start automatically Switch Router Startup Main Menu 1 Start Switch Router Application 2 Display Utility Menu Select 1 2 2 CP3140H BEG Boot Menu v1 0 Switch Router Startup Utility Menu 1 Start Switch Router Application 2 Load Code Update Package using TFTP 3 Display Vital Product Data 4 Select Serial Speed 5 Retrieve Error Log using TFTP 6 Erase Current Configuration 7 Erase Permanent Storage 8 Select Boot Method 9 BCM Debug Shell 10 Reboot Select option 1 10 10 Rebooting syncing filesystems This may take a few moments Rebooting system The system is going down NOW Sending SIGKIL
36. th2 Settings for eth2 Supported ports MII Supported link modes 10baseT Half 10baseT Full 100baseT Half 100baseT Full 1000baseT Half 1000baseT Full Supports auto negotiation Yes Advertised link modes 10baseT Half 10baseT Full 100baseT Half 100baseT Full 1000baseT Half 1000baseT Full Advertised auto negotiation Yes Speed 1000Mb s Duplex Full Port Twisted Pair PHYAD 1 Transceiver internal Auto negotiation on Supports Wake on g Wake on d Current message level 0x000000ff 255 Link detected yes 13 Repeat the steps for the other switch and RTM Sun Netra CP3x40 Switch Product Notes e January 2010 Configuring NetConsole VLAN55 Support The following script is provided to automate the configuration procedure for NetConsole VLAN55 support 1 Copy and paste the following text into a file CODE EXAMPLE 10 Script for Configuring NetConsole VLAN55 Support vlan database vlan 55 vlan name 55 Netconsole vlan exit configure 1 interface 0 1 lan acceptframe all lan participation include 55 lan tagging 55 lan ingressfilter xit nterface 0 2 lan ingressfilter xit nterface 0 3 lan acceptframe all lan participation include 55 lan tagging 55 lan ingressfilter xit nterface 0 4 lan acceptframe all lan participation include 55 lan tagging 55 lan ingressfilter xit nterface 0 5 lan acceptframe all lan participation include 55 lan tagging 55 lan ingressfilter xit nterfa
37. ur_tftpip gt lt dir gt lt filename gt system image m If using SNMP perform the following a Load the FASTPATH SWITCHING MIB b Use the agentTransferUploadGroup to update the code 8 Reboot the card reload 9 Repeat these steps for the other network Following is an example of the console output note that there might be slight variations depending on the settings and the software versions CODE EXAMPLE 3 Example Output for Upgrading the Firmware Through the FASTPATH Software CPU 400 MHz DRAM 128 MB FLASH 32 MB Booting Sun Netra CP3x40 Switch Product Notes e January 2010 CODE EXAMPLE 3 Example Output for Upgrading the Firmware Through the FASTPATH Software Continued Boot Menu v1 0 Select startup mode If no selection is made within 5 seconds the Switch Router Application will start automatically Switch Router Startup Main Menu 1 Start Switch Router Application 2 Display Utility Menu Select 1 2 1 Copying Application to RAM done Starting Application l File bootos c Line 244 Task lllcae34 EC 2863311530 Oxaaaaaaaa 0 d 0 hrs 0 min 20 sec Switch Router Starting PCI device BCM5695 BO attached as unit 0 PCI device BCM5695 BO attached as unit 1 Switch Router Started Unit 1 gt User admin Password NOTE Enter for Command Help Command help displays all options that are valid for the normal and no co
38. ware versions CODE EXAMPLE 2 Sample Output for Firmware Upgrade Through the Utility Menu Option CPU 400 MHz DRAM 128 MB FLASH 32 MB Booting Boot Menu v1 0 Select startup mode If no selection is made within 5 seconds the Switch Router Application will start automatically Switch Router Startup Main Menu 1 Start Switch Router Application 2 Display Utility Menu Select 1 2 2 Boot Menu v1 0 Switch Router Startup Utility Menu Start Switch Router Application Load Code Update Package using TFTP Display Vital Product Data Select Serial Speed Retrieve Error Log using TFTP Erase Current Configuration Erase Permanent Storage Select Boot Method BCM Debug Shell Reboot FPoOANA UU BUN HR l o Select option 1 10 2 Creating tmpfs filesystem on tmpfs for download done Enter Server IP 10 10 3 199 Enter Host IP dhcp Enter Gateway IP Enter Filename p CP3140 1 4 1 1 tgz Do you want to continue Press Y N y Bringing up eth0 interface done Transferring p CP3140 1 4 1 1 tgz from 10 10 3 199 done Sun Netra CP3x40 Switch Product Notes 9 10 CODE EXAMPLE 2 Sample Output for Firmware Upgrade Through the Utility Menu Option Continued Bringing down eth0 interface done Running update script Updating components Please wait Checking Vital Product Data Updating Switch Router Application Done De
39. witch Firmware Through the Boot Utility Menu 1 2 Set up a TFTP server on the update network Place the update image on the TFTP server Connect to the serial management port of the network to be updated and connect the MGMT port to the update network The Netra CP3140 switch has two external console ports one for 3 0 and 3 1 The Sun Netra CP3240 switch has a single external console port Reset the switch Following are the different methods that you can use to reset the switch Press the reset button on the switch Disengage and reengage the card injector ejector mechanisms at the top and bottom of the card Execute the reload command through the switch software As the switch resets press 2 to enter the Utility Menu Press 2 to choose to update the firmware through TFTP Enter the necessary information for your TFTP server For the host IP field you can enter dhcp if you would like to use DHCP to obtain a valid IP address Once the update is complete reset the switch If the update is only for the FASTPATH software you do not need to reboot and can press 1 instead Repeat these steps for the other network Note Use the key to toggle between Base and Fabric consoles on the Sun Netra CP3240 switch 8 Sun Netra CP3x40 Switch Product Notes e January 2010 Following is an example of the console output note that there might be slight variations depending on the settings and the soft
40. you like to save any configuration changes now y n n Configuration Not Saved Configuration script CP3240 Base SUN Netconsole scr applied 9 At the switch prompt use the show vlan lt VLAN ID gt command to verify that VLAN 55 is properly configured VLAN 55 should include ports 1 and 3 to 17 CP3240H BEX Z Base show vlan 55 VLAN ID 55 VLAN Name Netconsole vlan VLAN Type Static Interface Current Configured Tagging 0 1 Include Include Tagged 0 2 Exclude Autodetect Untagged 0 3 Include Include Tagged 0 4 Include Include Tagged 0 5 Include Include Tagged 0 6 Include Include Tagged 0 7 Include Include Tagged 0 8 Include Include Tagged 0 9 Include Include Tagged 0 10 Include Include Tagged 0 11 Include Include Tagged 0 12 Include Include Tagged 0 13 Include Include Tagged 0 14 Include Include Tagged 0 15 Include Include Tagged 0 16 Include Include Tagged 0 17 Include Include Tagged 0 18 Exclude Autodetect Untagged More or q uit Sun Netra CP3x40 Switch Product Notes e January 2010 10 Save the running config into startup config by using the copy system running config nvram starup config command as shown in the following example CP3240H BEX Z Base copy system running config nvram startup config This operation may take a few minutes Management interfaces will not be available during this time Are you sure you want to save y n y Configurat