Home
        Sun Storage 2500-M2 Arrays
         Contents
1.  During Controller Firmware Download    Operating System   m Oracle Linux 5 8 with UEK kernel release 2 6 32 300 10 1 el5uek   m Oracle Linux 6 2 with UEK kernel release 2 6 32 300 3 1 el6uek   m Device Mapper MultiPath release 0 4 9 23 0 9 e15 and release 0 4 9 46 0 1 e16     Hardware Software Firmware  m All controllers    m Controller firmware release 7 84    Problem or Restriction    Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 17    This problem occurs when you upgrade controller firmware  A host with the  affected kernel with UEK support experiences a devloss error for one of the world   wide port numbers  WWPNs  followed by a kernel panic     Workaround  To avoid this problem  upgrade the host kernel to release 2 6 32 300 23 1     If the problems occurs  power cycle the host     Network Interface on Device ethO Fails to Come Online  When Booting a Host    Operating System  m Oracle Linux 5 8 with UEK kernel release 2 6 32 300 10 1 el5uek    Hardware Software Firmware    m Controller firmware release 7 84  Problem or Restriction    This problem occurs during a host boot process when a large number  112   of  volumes are mapped to the host  At the point in the boot process where the network  interface should be brought online  the host displays the following message     Bringing up interface eth0  Device eth0 has different MAC address  than expected   FAILED        The network interface does not come online during the boot process  and cannot  s
2.  com handbook partner Systems 2530 M2 2530  _M2 html    https   support oracle com handbook partner Systems 2540 M2 2540  _M2 html    Array Expansion Module Support    The Sun Storage 2530 M2 and 2540 M2 arrays can be expanded by adding Sun  Storage 2501 M2 array expansion trays  To add capacity to an array  refer to the  following Service Advisor procedures     m Adding Expansion Trays    m Upgrade Firmware       Caution     To add trays with existing stored data  contact My Oracle Support for  assistance to avoid data loss        TABLE1 IOM Code for Sun Storage 2501 M2 Expansion Tray       Supported Expansion  Array Controller Firmware Tray IOM Code    Sun Storage 2500 M2 07 84 47 10 2501 M2  0366         Only 2501 M2 expansion trays are supported with a 2500 M2 controller tray    Data Host Requirements    m  Multipathing Software  on page 5  m  Supported Host Bus Adaptors  HBAs   on page 7  m  Supported FC and Multilayer Switches  on page 9    Multipathing Software    You must install multipathing software on each data host that communicates with  the Sun Storage 2500 M2 arrays     Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 5    m Download the latest RDAC MPP or MPIO failover driver from MOS     https   support oracle com  m MPxIO driver is included with the Solaris OS    m For additional information on multipathing software  see the following     Sun Storage 2540 M2 Multipath Software Compatibility Matrix  Doc ID 1508701 1     https   support o
3.  marks the path failed and fails over to the alternate path     Workaround    The logging of this message does not affect normal operation  You can disable the  log message by entering the following command on the host command line     echo 0     proc sys kernel hung task timeout secs    Backup Failure or I O Errors with Snapshot Creation or  Mounting Failure During Backup of Cluster Shared  Volumes  CSV     Operating System  m Windows 2008 R2 Server  all editions  running Hyper V cluster with CSV    Problem or Restriction    This problem occurs when a backup operation of CSVs begins  The backup  application talks to the VSS provider and initiates the backup operation  The  creation of a snapshot volume or mounting of a snapshot volume fails  The backup  application then tries to backup the CSVs instead of a snapshot of the CSVs  If the  Retry option is set with lock  the application hosted on the CSVs or data written to  or read from these volumes might throw an error  If the Retry option is set without  lock  the backup skips files  This error occurs because the backup application and the  application hosted on the CSVs or data being written to or read from the CSVs tries  to  lock  the volume or file  which results in a conflict     Users encounter this issue whenever there is a resource conflict between the backup  operation and the application trying to perform write or read operations to the  volume undergoing a backup operation     Sun Storage 2500 M2 Arrays Hardware R
4. 2500 M2 Arrays Safety and Compliance Manual  Important Safety Information for Sun Hardware Systems    Sun Storage Common Array Manager Release Notes    Sun Storage 2500 M2 Arrays Site Preparation Guide  Sun Storage 2500 M2 Arrays Support Rail Installation Guide  Sun Storage 2500 M2 Arrays Hardware Installation Guide    Sun Storage Common Array Manager Quick Start Guide    Sun Storage Common Array Manager Installation and Setup Guide    Sun Storage Common Array Manager Array Administration Guide  Sun Storage Common Array Manager CLI Guide    Sun StorageTek MPIO Device Specific Module Installation Guide For  Microsoft Windows OS   Sun StorageTek RDAC Multipath Failover Driver Installation Guide  For Linux OS       Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 29       Documentation  Support  and Training    These web sites provide additional resources     m Documentation  http   www oracle com technetwork indexes documentation   index html    m Support  https   support oracle com    m Training  https   education oracle com    30 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    
5. 47661 xx Windows  147418 xx Linux 147662 xx Linux  147419 xx Solaris X86         xxindicates the most recent patch revision     Upgrading Controller Firmware    Before you perform an online controller firmware upgrade  read the article  Recommended Setting for the    cp o    line delay  Variable When Upgrading a Sun  Storage 6000  2500 or 2500 M2 Controller Firmware  Doc ID 1569976 1  located on  MOS  This article describes how to modify fibre channel timeout values for Solaris  SPARC and x86 hosts     Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013       Product Overview    The Sun Storage 2500 M2 arrays are a family of storage products that provide high   capacity  high reliability storage in a compact configuration  The controller tray  with  two controller modules  provides the interface between a data host and the disk  drives  Two array models and one expansion tray are offered     m The Sun Storage 2540 M2 array provides a Fibre Channel  FC  connection  between the data host and the controller tray at 8 Gbit sec     m The Sun Storage 2530 M2 array provides a Serial Attached SCSI  SAS  connection  between the data host and the controller tray at 6 Gbit sec     m The Sun Storage 2501 M2 array expansion tray provides additional storage via  SAS interface at 6 Gbit sec  It is connected to either of the above controller tray  models     The Sun Storage 2500 M2 arrays are modular and rack mountable in industry   standard cabinets  The ar
6. 50   Lpe12000 LPe12002    LPe1250      For generic HBA support  contact the HBA manufacturer     TABLES Supported Fibre Channel HBAs for Windows Data Host Platforms       Generic HBAs    Sun 2 Gb HBAs Sun 4 Gb HBAs Sun 8 Gb HBAs  OLogic  SG XPCI1FC EM2 SG XPCIE1FC QF4 SG XPCIE1FC QF8 Z  QLE 256x SG XPCI2FC EM2 SG XPCIE2FC QF4 SG XPCIE2FC QF8 Z  QLE 246x SG XPCI1FC QL2 SG XPCIE1FC EM4 SG XPCIE1FC EM8 Z  QLA 246x SG XPCDFC OF2 Z SG XPCIE2FC EM4 SG XPCIE2FC EM8 Z  QLA 234x SG XPCI1FC QF4 SG XPCIEFCGBE Q8  QLA 2310F SG XPCI2FC QF4 SG XPCIEFCGBE E8  Emulex  SG XPCI1FC EM4   LPe12000 LPe12002  SG XPCI2FC EM4   LPe1250 SG XPCIE2FCGBE Q    Lpe11000 LPe11002 LP Z   e1150 SG XPCIE2FCGBE E Z  LP11000 LP11002 LP11   50   LP9802 9802DC  982   LP952 LP9002 LP9002   DC   10000 10000DC LP1050         For generic HBA support  contact the HBA manufacturer     8 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    TABLE6 Supported SAS HBAs for Solaris and Linux Data Host Platforms       Oracle 3 Gbit HBAs  SAS 1   Oracle 6 Gbit HBAs  SAS 2 t  SG XPCIE8SAS E Z SG X  SAS6 EXT Z  SG XPCIE8SAS EB Z SG X  SAS6 EM Z         See  SAS 1 HBA Settings  on page 9    t See  Restrictions  on page 14    TABLE7 Supported SAS HBAs for Microsoft Windows Data Host Platforms       Oracle 3 Gbit HBAs  SAS 1  Oracle 6 Gbit HBAs  SAS 2        SG XPCIE8SAS E Z SG X  SAS6 EXT Z  SG X  SAS6 EM Z       SAS 1 HBA Settings  See the release notes for your HBA hardware for firmware suppor
7. CFW   Download   Operating System   m Oracle Linux 5 7 with UEK kernel release 2 6 32 200 13 1 el5uek  Hardware Software Firmware    m All controllers    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when you upgrade CFW  The kernel panics on an attached host  when downloading the CFW and shows the following message     Kernel panic   not syncing  Fatal exceptionBUG  unable to handle  kernel NULL pointer dereference at 0000000000000180IP        fffffff8123450a    kref_get 0xc 0x2aPGD 3c275067 PUD 3c161067 PMD  0 Oops  0000   1  SMPlast sysfs file   sys block sdc dev    16 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Workaround    To avoid this problem  do not perform a CFW upgrade on a storage array that is  attached to hosts running the affected operating system version  If the problems  occurs  power cycle the host     BCM Driver Fails to Load  Operating System  m Windows Server 2012 build 9200    Hardware Software Firmware  m All controllers    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when you attempt to install the BCM driver on a server  The  driver installs  but the component reports one of the following errors     This device is not configured correctly   Code1 The system cannot find the file  specified     or    The drivers for this device are not installed   Code 28 The system cannot find the file  specified     Workaround    None     Kernel Panics
8. Sun Storage 2500 M2 Arrays    Hardware Release Notes  Release 6 9 x October  2013 Update    SS  4   Sun  vue    Copyright    2011 2013  Oracle and or its affiliates  All rights reserved     This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by  intellectual property laws  Except as expressly permitted in your license agreement or allowed by law  you may not use  copy  reproduce  translate   broadcast  modify  license  transmit  distribute  exhibit  perform  publish  or display any part  in any form  or by any means  Reverse engineering   disassembly  or decompilation of this software  unless required by law for interoperability  is prohibited     The information contained herein is subject to change without notice and is not warranted to be error free  If you find any errors  please report them to us  in writing    If this is software or related software documentation that is delivered to the U S  Government or anyone licensing it on behalf of the U S  Government  the  following notice is applicable     U S  GOVERNMENT END USERS  Oracle programs  including any operating system  integrated software  any programs installed on the hardware   and or documentation  delivered to U S  Government end users are  commercial computer software  pursuant to the applicable Federal Acquisition  Regulation and agency specific supplemental regulations  As such  use  duplication  disclosure  modificatio
9. TP LSI  V SUN  M  LCSM100 S      esxcli nmp satp apprule  V SUN  M LCSM100 S  c tpgs off   s VMW SATP LSI    Reboot the ESX host       To manually add the SATP rule in ESXi 5 0     Open a terminal to the ESX host and run the following command      esxcli storage nmp satp rule add  s VMW SATP ALUA  V SUN   M LCSM100 S  c tpgs on    Reboot the ESX host     2  Verify the claim rule is added in ESX     a     ESX 4 1    To show a list of all the claim rules      esxcli nmp satp listrules      List only the claim rules for the VMW SATP LSI      esxcli nmp satp listrules  s VMW SATP LSI      Verify that the claim rule for the VID PID is SUN LCSM100 S  for 2530 M2     or SUN LCSM100 F  for 2540 M2  and the  Claim Options     tpgs off  flag is  specified     ESXi 5 0      To show a list of all the claim rules      esxcli storage nmp satp rule list      List only the claim rules for the VMW_SATP_ALUA      esxcli storage nmp satp rule list  s VMW SATP ALUA    Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 11    c  Verify that the claim rule for VMW SATP ALUA is VID PID  SUN LCSM100 S  for 2530 M2  or SUN LCSM100 FLS  for 2540 M2  and the   Claim Options   tpgs on  flag is specified     3  Upgrade the storage array controllers to firmware 07 84 44 10  minimum  and  NVSRAM versions     4  From the host management client  verify that the host OS type is set to   VMWARE     Starting with firmware 07 84 44 10  VMWARE    host type will have  the ALUA and TPGS bits enab
10. atch download steps  see the Knowledge article 1296274 1 available on  MOS       How to Download Common Array Manager  CAM  Software and Patches  ID  1296274 1     Note     Each array should be managed by one CAM management host only   Installing the management software on more than one host to manage the same  array can cause discrepancies in the information reported by CAM        System Requirements    The software and hardware products that have been tested and qualified to work  with Sun Storage 2500 M2 arrays are described in the following sections  Sun  Storage 2500 M2 arrays require Sun Storage Common Array Manager  Version 6 9 0   or higher  software     m  Firmware Requirements  on page 4  m  Supported Disk Drives and Tray Capacity  on page 5  m  Array Expansion Module Support  on page 5    m  Data Host Requirements  on page 5    Firmware Requirements    The Sun Storage 2500 M2 arrays firmware version 07 84 47 10 is installed on the  array controllers prior to shipment and is also delivered with the latest platform and  firmware patches for Sun Storage Common Array Manager  CAM   Version 6 9 0     Firmware is bundled with the CAM software download package  To download  CAM  follow the procedure in  Downloading Patches and Updates  on page 4     4 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Supported Disk Drives and Tray Capacity    See the Sun System Handbook for the latest disk drive information     https   support oracle
11. blem occurs when you attempt to add more that 117 volumes to the  database of the OVM manager  When the OVM manager scans for the additional  volumes  it returns the following error        OSCPlugin OperationFailedEx  Unable to query ocfs2 devices     Workaround    You can avoid this problem by deleting volumes from the OVM manager database  when those volumes are no longer mapped to the OVM server     Write Back Cache is Disabled after Controllers Reboot  with Multiple Failed Volumes in a Storage Array    Operating System  m All    Hardware Software Firmware  m All controllers    m Controller firmware release 7 84    Problem or Restriction    20 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    This problem occurs when power is turned off and then back on to a controller drive  tray while there are failed volumes in the storage array  When the controllers reboot  after the power cycle  they attempt to flush restored cache data to disk  If the  controllers are unable to flush the cache data because of failed volumes  all of the  volumes in the storage array remain in write through mode after the controllers  reboot  This will cause a substantial reduction in performance on input output  operations     Workaround    None     During Multiple Node Failover Failback Events   Input Output  I O  Operations Time Out Because a  Resource is Not Available to a Cluster    Operating System    m Red Hat Enterprise Linux 6 2 with DMMP and SteelEye Lif
12. c  d   sous licence au Gouvernement des Etats Unis  ou    toute entit   qui d  livre la licence de  celogiciel ou l utilise pour le compte du Gouvernement des Etats Unis  la notice suivante s applique      U S  GOVERNMENT END USERS  Oracle programs  including any operating system  integrated software  any programs installed on the hardware   and or documentation  delivered to U S  Government end users are  commercial computer software  pursuant to the applicable Federal Acquisition  Regulation and agency specific supplemental regulations  As such  use  duplication  disclosure  modification  and adaptation of the programs  including  any operating system  integrated software  any programs installed on the hardware  and or documentation  shall be subject to license terms and license  restrictions applicable to the programs  No other rights are granted to the U S  Government    Ce logiciel ou mat  riel a   t   d  velopp   pour un usage g  n  ral dans le cadre d applications de gestion des informations  Ce logiciel ou mat  riel n est pas  concu ni n est destin        tre utilis   dans des applications   risque  notamment dans des applications pouvant causer des dommages corporels  Si vous  utilisez ce logiciel ou mat  riel dans le cadre d applications dangereuses  il est de votre responsabilit   de prendre toutes les mesures de secours  de  sauvegarde  de redondance et autres mesures n  cessaires    son utilisation dans des conditions optimales de s  curit    Oracle Corporation e
13. cribe how to add ALUA TPGS with VMware support   Starting with firmware 07 84 44 10  the ALUA TPGS enabled arrays will be  managed by the VMW_SATP_ALUA plug in  Arrays with firmware previous to  07 84 44 10 will be managed by the current VMW_SATP_LSI plug in     Prerequisite   1  Firmware version previous to 07 84 44 10 is loaded on controllers     2  Current storage array devices are managed by the standard VMW_SATP_LSI  plug in     3  Management host is available     4  Starting with firmware 07 84 44 10  the ALUA TPGS enabled arrays will be  managed by the VMW_SATP_ALUA plug in     5  Non TPGS array will be managed by the current standard VMW_SATP_LSI plug   in     6  Path policy supported is still Round Robin  RR  or Most Recently Used  MRU      10 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    V Procedure  Offline    for ESX4 1U2  ESXi5 0 and  prior    1  Upgrade to firmware 07 84 44 10  minimum  on the management host   Currently  VMware  i e  ESXi5 0 and 4 1u1 u2  do not have the claim rules  automatically set to select the VMW SATP  ALUA to claim our arrays that have  the TPGS bit enabled  You must manually add the claim rule in ESX     The following example adds the claim rule for the 2530 M2 using VID PID    SUN LCSM100_S  For 2540 M2 arrays  use VID PID SUN LCSM100 F     a     To manually add the SATP rule in ESX 4 1Ux   Open a terminal to the ESX host and run the following commands      esxcli nmp satp deleterule  s VMW SA
14. eKeeper Clustering  application    Hardware Software Firmware  m All controllers    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when a cluster loses access to a file system resource  A message  similar to the following appears in the cluster log     Device  dev mapper mpathaa not found  Will retry wait to see if it  appears  The device node  dev mapper mpathaa was not found or did  not appear in the udev create time limit of 60 secondsFri Apr 27  18 45 08 CDT 2012 restore  END restore of file system  home smashmnt11   err 1  ERROR  restore action failed for resource  home smashmnt11   opt LifeKeeper bin lcdmachfail  restore in parallel of resource   dmmp19021 has failed  will re try seriallyEND vertical parallel  recovery with return code  1       You might experience I O timeouts   Workaround    If this problem occurs  restart I O operations on the storage array     Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 21    After an NVSRAM Download  a Controller Reboots a  Second Time when the NVSRAM is Activated   Operating System   m All    Hardware Software Firmware    All controllers  m Controller firmware releases 7 80 through 7 84    m Problem or Restriction    This problem occurs when a controller detects corruption in the signature of the  NVSRAM loaded on the controller  The controller restores the NSVRAM from the  physical drive  and then reboots     Workaround    The controller recovers and continues normal o
15. elease Notes  October 2013 Update 25    Depending on the option the customers choose  the backup operation reports one of  these conditions     m Skipped files  m Application reports errors    m Write or read operation to the volume under backup reports errors  Workaround    Run the backup operation at a time when the application is not doing write or read  intensive work on the CSV undergoing backup     Also  when using the option  Without Lock   files will be skipped and the user can  then create another backup operation with the skipped files  For more information   see http    www symantec com docs TECH195868    With Multiple SAS Hosts Using Single PHY  a Host Cable  Pull During Input Output  I O  Operations Causes a  Controller Reboot    Operating System  m All    Hardware Software Firmware  m Controllers with SAS host connections    m Controller firmware release 7 84  Problem or Restriction    This problem rarely occurs when multiple hosts are connected by a quadfurcated  cable to a single wide port on the controller  If the cable is disconnected  the  controller reboots     Workaround    The controller reboots and return to normal operations when the cable is  reconnected     Data is Misread when a Physical Drive Has an  Unreadable Sector    Operating System  m Red Hat Enterprise Linux 6 x    26 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Hardware Software Firmware  m All controllers    m Controller firmware release 7 84  Pr
16. en you re install the OVM manager on the host using the  same ID as the previous installation  ISO file systems that were imported with the  previous OVM manager are now renamed with their UUIDs rather than their  friendly names  This makes it difficult to identify the ISO file systems     Workaround    None     After Un Mapping a Volume from an Oracle Virtual  Machine  OVM  Server  the Volume Continues to Appear  in the Storage Database on the Server    Operating System  m OVM 3 03 with the generic SCSI plug in    Hardware Software Firmware    m All controllers  Problem or Restriction    This problem occurs when you un map a volume on an OVM server  The OVM  manager continues to show the volume along with those that are still mapped to the  server  When you try to assign one of the affected volumes to a virtual machine  you  see this error message     Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 15    disk doesn t exist  Workaround    After you un map the volumes  use the OVM manager to remove those volumes  from the storage database on the server     In the Oracle Virtual Machine  OVM  Manager User  Interface  Only One Drive at a Time Can Be Selected for  Deletion    Operating System  m OVM 3 03 with the generic SCSI plug in    Hardware Software Firmware    wm All controllers   Problem or Restriction   In the OVM user interface  only one drive at a time can be selected for deletion   Workaround    None     Kernel Panics During Controller Firmware  
17. is no redundancy  and a connection failure will result in loss of access to the    array   Caution     Because of the single point of failure  single path data connections are  not recommended        SAS Host Ports on the Sun Storage 2540 M2    Although SAS host ports are physically present on the Sun Storage 2540 M2 array  controller tray  they are not for use  not supported  and are capped at the factory   FIGURE 1 shows the location of these ports  The Sun Storage 2540 M2 only supports  Fibre Channel host connectivity     FIGURE1 SAS Host Ports on the 2540 M2    2540 M2                                     Controller Issues    Log Events Using SLES 11 1 With smartd Monitoring  Enabled    Bug 7014293   When volumes are mapped to a SLES 11 1 host with smartd  monitoring enabled  on either a Sun Storage 2500 M2 or 6780 array  it is possible to  receive  IO FAILURE    and  Illegal Request ASC  ASCQ  log events     14 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Workaround   Either disable smartd monitoring or disregard the messages  This is  an issue with the host OS     After Re Installing the Oracle Virtual Machine  OVM   Manager  International Standards Organizations  ISO   Files Are Listed by Universally Unique Identifier  UUID   Rather Than by Friendly Name    Operating System   m Oracle OVM 3 0 3  Hardware Software Firmware  m All controllers    m Controller firmware release 7 84  Problem or Restriction    This problem occurs wh
18. led by default     5  Perform a manual re scan and verify from the ESX host that the TPGS ALUA  enabled devices are claimed by the VMW SATP ALUA plug in   To confirm that the host is using the ALUA plugin   m ESX 4 1    a  Run the command    esxcli nmp device list  b  The value for Storage Array Type should be  VMW_SATP_ALUA  on every    device from the array with firmware 07 84 44 10  or later   On arrays with  firmware previous to 07 84 44 10  the value should be  VMW_SATP_LSI      m ESXi 5 0    a  Run the command      esxcli storage nmp device list    b  The value for Storage Array Type should be  VMW SATP ALUA  on every  device from the array with firmware 07 84 44 10  or later   On arrays with  firmware previous to 07 84 44 10  the value should be  VMW SATP LSTI      V Procedure  Offline    starting at ESX4 1U3   ESXi5 0U1 and above    1  Upgrade to firmware 07 84 44 10  minimum  on the management station     2  Starting with ESXi5 0 U1 and ESX4 1U3  VMware will automatically have the  claim rules to select the VMW_SATP_ALUA plug in to manage arrays that have  the TPGS bit enabled  All arrays with the TPGS bit disabled will continue to  be managed by the VMW_SATP_LSI plug in     3  Upgrade the storage array controllers to firmware 07 84 44 10  minimum  and  NVSRAM versions     12 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    4  From the Host Management client  verify that the host OS type is set to   VMWARE    Starting with firm
19. mware  m Hosts attached through a SAS switch    m Controller firmware release 7 84  Problem or Restriction    This problem occurs during a controller firmware upgrade  The operating system  logs task abort messages similar to those shown below     May 3 21 30 51 ictc eats kernel   118114 764601  sd 0 0 101 3  task  abort  SUCCESS scmd ffff88012383c6c0 May 3 21 30 51 ictc eats  kernel   118114 764606  sd 0 0 101 1  attempting task abort   scmd ffff88022705c0cO May 3 21 30 51 ictc eats kernel    118114 764609  sd 0 0 101 1  CDB  Test Unit Ready  00 00 00 00 00 00  May 3 21 30 51 ictc eats kernel   118114 764617  scsi target0 0 101   handle 0x000c   sas address 0x50080e51b0bae000   phy 4 May 3  21 30 51 ictc eats kernel   118114 764620  scsi target0 0 101   enclosure logical id 0x500062510000a8ff   slot 4 May 3 21 30 51  ictc eats kernel   118114 767084  sd 0 0 101 1  task abort  SUCCESS  scmd ffff88022705c0c0           Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 19    You might experience input output  I O  timeouts or read write errors after the  upgrade     Workaround    If this problem occurs  restart input output operations  the affected resources will  come back online without further intervention     Unable to Add More Than 117 Volumes to the Oracle  Virtual Machine  OVM  Manager Database    Operating System  m Oracle VM 3 0 3  Hardware Software Firmware    All controllers    m Controller firmware release 7 84  Problem or Restriction    This pro
20. n  and adaptation of the programs  including  any operating system  integrated software  any programs installed on the hardware  and or documentation  shall be subject to license terms and license  restrictions applicable to the programs  No other rights are granted to the U S  Government        This software or hardware is developed for general use in a variety of information management applications  It is not developed or intended for use in any   inherently dangerous applications  including applications which may create a risk of personal injury  If you use this software or hardware in dangerous   applications  then you shall be responsible to take all appropriate fail safe  backup  redundancy  and other measures to ensure its safe use  Oracle  orporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications     Oracle and Java are registered trademarks of Oracle and or its affiliates  Other names may be trademarks of their respective owners     Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation  All SPARC trademarks are used under license and are trademarks or  ie trademarks of SPARC International  Inc  AMD  Opteron  the AMD logo  and the AMD Opteron logo are trademarks or registered trademarks of  Advanced Micro Devices  UNIX is a registered trademark of The Open Group     This software or hardware and documentation may provide access to or information on content  prod
21. ning Fault  Tolerance off and on for running VMs  or that  even after performing the previous  action  a secondary VM still does not start  If the secondary VM does not start  the  customer needs to briefly shut down the affected VM  perform action 2  and then  restart the VM     Documentation Bugs    Hardware Installation Guide    Page 38 of the Sun Storage 2500 M2 Arrays Hardware Installation Guide mistakenly  refers to AIX and HP UX as supported data host platforms  Disregard HP UX and  AIX referenced in the following note      The data host multipathing software for Red Hat Linux  HP UX  AIX  and Windows  platforms is Sun Redundant Dual Array Controller  RDAC   also known as MPP      28 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013       Related Documentation    Product documentation for Sun Storage 2500 M2 arrays is available at     http   www oracle com technetwork documentation oracle unified     88 193371 html    Product documentation for Sun Storage Common Array Manager is available at     http   www oracle com technetwork documentation disk device     194280 html    TABLE 9    Related Documentation       Application    Title       Review safety information    Review known issues and  workarounds    Prepare the site  Install the support rails  Install the array    Get started with the  management software    Install the management  software    Manage the array    Install and configure  Multipath failover drivers    Sun Storage 
22. oblem or Restriction    This problem occurs when issuing a read to a location where the length of the read  includes an unreadable sector  The host operating system assumes that data up to  the unreadable sector was read correctly  but this might not be the case  A bug has  been opened with Red Hat  http    bugzilla redhat com show  bug cgi id 845135    Workaround    Replace any drives that have media errors     Solaris 10 Guest in Fault Tolerant Mode Is Unable to  Relocate Secondary Virtual Machine  VM  Upon Host  Failure    Operating System  m Solaris 10 VM    Hardware Software Firmware    m ESXi 5 1 hosts in HA cluster configuration configured in fault tolerant mode with  heavy I O    Problem or Restriction    This problem occurs when the host fails while the host was running a secondary VM  for a Solaris 10  u10  guest  The message in the event log for that VM that reads as  follows     No compatible host for the Fault Tolerant secondary VM    When this problem occurs  the secondary VM for the guest is stuck in an Unknown  status and cannot re enable Fault Tolerance for this VM  An attempt to disable and  then re enable Fault Tolerance fails because it cannot relocate the secondary VM  from a host that is not responding  Also Fault Tolerance cannot be completely turned  off on the VM for the same reason     The main problem is that the HA service reports that there are not enough resources  available to restart the secondary VM  However  even after reducing all used  reso
23. perations     When a Controller is Not Set Offline Before Being  Replaced  an Exception Occurs when the Replacement  Controller is Brought Online    Operating System   m All  Hardware Software Firmware  m All controllers    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when you fail to follow standard procedures when replacing a  controller  If you do not set a controller offline before you replace it  and the  replacement controller has a difference firmware level from the remaining controller   the firmware mismatch is not properly detected     Workaround    You can avoid this problem by following the standard procedure for replacing a  controller  If this problem occurs  the replacement controller reboots after the  exception and the storage array returns to normal operations     22 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Input Output  I O  Errors Occur when Disconnection of  Devices from a SAS Switch Is Not Detected    Operating System   m All   Hardware Software  Firmware   m Controllers attached to hosts through SAS switches    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when there is a heavy load of I O operations between hosts  and storage arrays that are connected through a SAS switch  The switch fails to  notify the host when a volume is no longer available  A host experiences I O errors  or application timeouts     Workaround    To avoid this p
24. racle com epmos faces DocContentDisplay id     L508 704 4      Sun Storage 2530 M2 Multipath Software Compatibility Matrix  Doc ID 1509474 1   https   support oracle com epmos faces DocContentDisplay id     1509474 1         Sun StorageTek RDAC Multipath Failover Driver Installation Guide For Linux OS    m Single path data connections are not recommended  For more information  see       Single Path Data Connections  on page 14     TABLE2 Supported OS and Multipathing Software       os  Solaris 11  initial     Solaris 11 ALUA TPGS    Multipathing Software  MPxIO  MPxIO  TPGS     Solaris 10u5  minimum  MPxIO   Oracle Linux 6 3  6 2  6 1  6 0 RDAC DMMP  Oracle Linux 5 8  5 7  5 6  5 5 RDAC   Oracle Unbreakable Linux DMMP   Oracle Unbreakable Linux 2   Oracle VM 3 1 1 DMMP   Oracle VM 2 2 2 RDAC   RHEL 6 3  6 2  6 1  6 0 RDAC DMMP  RHEL 5 8  5 7  5 6  5 5 RDAC   SLES 10 4  10 3  10 2  10 1  10 0 RDAC MPP  SLES 11 2  11 1  11 0 RDAC DMMP  Windows 2003 SP2 R2 Non clustered MPIO  Windows 2003 2008 MSCS Cluster MPIO  Windows 2008 SP1 R2  64 bit only  MPIO         Oracle recommends installing the latest Solaris update     6 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Supported Host Bus Adaptors  HBAs     m HBAs must be ordered separately from Oracle or its respective manufacturers   m To obtain the latest HBA firmware     a For Fibre Channel HBAs  download firmware from My Oracle Support using  keyword    HBA     For download instructions  
25. rays are scalable from a single controller tray configuration  to a maximum configuration of one controller tray and seven expansion trays  The  maximum configuration creates a storage array with a total of 96 drives connected to  2530 M2 or 2540 M2 controllers or a total of 192 drives connected to 4GB 2540 M2  controllers  available as an upgrade or with new 2540 M2 controllers      Use the latest version of Sun Storage Common Array Manager to manage the arrays   See    About the Management Software    on page 3 for more information        About the Management Software    Oracle   s Sun Storage Common Array Manager  CAM  software is a key component  for the initial configuration  operation  and monitoring of Sun Storage 2500 M2  arrays hardware  It is installed on a management host cabled to the array via out of   band Ethernet  Note  In band management is also supported     To download CAM  follow the procedure in the section    Downloading Patches and  Updates    on page 4  Then  review the latest Sun Storage Common Array Manager  Quick Start Guide and Sun Storage Common Array Manager Installation and Setup Guide  to begin installation  CAM documentation can be found here     http   www  oracle com technetwork documentation disk device   194280 html    Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 3       Downloading Patches and Updates    Download the latest platform and firmware patch  see TABLE 1  from My Oracle  Support  MOS      For detailed p
26. roblem  reduce some or all of the following factors   m The number of ports on the switch that are used or zoned  m The number of volumes mapped to hosts through the switch    m The throughput of I O operations    A Path Failure and Premature Failover Occur when a  Cable is Disconnected between a Host and a Controller    Operating System    m Red Hat Enterprise Linux operating systems with Device Mapper Multipath   DMMP     Hardware Software Firmware  m Controller drive trays with SAS host connections    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when you disconnect a SAS cable between a controller and a  host  Even if you reconnect the cable before the normal failover timeout  the path  fails and the controller fails over to the alternate     Workaround    If this problem occurs  reconnect the cable  The path will be restored     Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 23    Input Output  I O  Errors Occur when a Cable is  Disconnected between a Host and a Controller  and the  Alternate Controller is Unavailable   Operating System    m Red Hat Enterprise Linux operating systems with Device Mapper Multipath   DMMP     Hardware Software Firmware  a All controllers    a Controller firmware release 7 84  Problem or Restriction    This problem occurs when the maximum number of volumes  256  is mapped to a  host  If you disconnect the cable between a controller and a host  and then reconnect  the cable  I O erro
27. rs occur if the alternate controller becomes unavailable before the  host can rediscover all of the volumes on the connection     Workaround    After some delay  the host will rediscover all of the volumes and normal operations  will resume     With 3 Gb s SAS Host Bus Adapters  HBAs  and Heavy  Input Output  I O   I O Timeouts Occur During a  Controller Firmware Upgrade   Operating System    m Red Hat Enterprise Linux operating systems with Device Mapper Multipath   DMMP     Hardware Software Firmware  m Hosts with 3 Gb s SAS host bus adapters    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when you upgrade controller firmware during a heavy load of  I O operations  The host experiences I O timeouts during firmware activation     Workaround  Do not perform an online controller firmware upgrade while the system is under    heavy I O load  If this problem occurs  restart I O operations on the host     24 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    Host Operating System Logs  Hung Task  During a Path  Failure    Operating System   m Red Hat Enterprise Linux 5 0 and later with multipath proxy  MPP  driver  Hardware Software Firmware   m Hosts with SAS host bus adapters    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when there is a path failure through a host connection  The  operating system logs a  Hung Task  message in  var log messages before the MPP  driver
28. s Sun Storage   2500 M2 arrays managed by Sun Storage Common Array Manager  CAM   Version  6 9 0  Read this document so that you are aware of issues or requirements that can  affect the installation and operation of the array     The release notes consist of the following sections      What s New in This Release  on page 2     Product Overview  on page 3      About the Management Software    on page 3     Downloading Patches and Updates    on page 4     System Requirements    on page 4     ALUA TPGS with VMware    on page 10     Notable Fixes    on page 13      Restrictions and Known Issues    on page 13     Related Documentation    on page 29       Documentation  Support  and Training    on page 30    What s New in This Release    m 2500 M2 firmware 07 84 47 10 delivered with the latest CAM 6 9 firmware patch    m 600GB 10K rpm  2 5 inch SAS disk drive support  Requires drive firmware  H109060SESUN600G version A31  delivered with patches 147660 05  Solaris    147661 04  Windows   147662 04  Linux         Note   It is recommended that you avoid using disk drives with different spindle  speeds in the same volume group  Doing so will impact system performance        Platform and Firmware Patch IDs    Refer to the latest Sun Storage Common Array Manager release notes for the most  recent patch versions     TABLE1 Platform and Firmware Patch IDs          Platform patch Operating System Firmware patch Operating System  147416 xx Solaris SPARC 147660 xx Solaris  147417 xx Windows 1
29. see  Downloading Patches and  Updates  on page 4     a For SAS HBAs  go to  http    www 1lsi com sep Pages oracle index aspx    m You must install multipathing software before you install any OS patches     m Download OS updates from the web site of the OS company     TABLE3 Supported Fibre Channel HBAs for Solaris Data Host Platforms       Oracle 2 Gbit HBAs Oracle 4 Gbit HBAs Oracle 8 Gbit HBAs  SG XPCI1FC QL2  6767 A  SG XPCIE1FC QF4 SG XPCIE1FC QF8 Z  SG XPCI2FC QF2 Z  6768A  SG XPCIE2FC QF4 SG XPCIE2FC QF8 Z  SG XPCI1FC EM2 SG XPCIE1FC EM4 SG XPCIE1FC EM8 Z  SG XPCI2FC EM2 SG XPCIE2FC EM4 SG XPCIE2FC EMS8 Z  SG XPCI1FC QF4 SG XPCIEFCGBE Q8  SG XPCI2FC QF4 SG XPCIEFCGBE E8    SG XPCI1FC EM4  SG XPCI2FC EM4  SG XPCIE2FCGBE O Z  SG XPCIE2FCGBE E Z       Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update    7    TABLE4 Supported Fibre Channel HBAs for Linux Data Host Platforms       Generic HBAs  Oracle 2 Gbit HBAs Oracle 4 Gbit HBAs Oracle 8 Gbit HBAs  OLogic  SG XPCI1FC EM2 SG XPCIE1FC QF4 SG XPCIE1FC QF8 Z  QLE 256x SG XPCDFC EM2 SG XPCIE2FC QF4 SG XPCIE2FC QF8 Z  QLE 246x SG XPCHFC OL2   SG XPCIE1FC EM4 SG XPCIE1FC EM8 Z  QLA 246x SG XPCI2FC QF2 Z SG XPCIE2FC EM4 SG XPCIE2FC EM8 Z   QLA 234x SG XPCI1FC QF4 SG XPCIEFCGBE Q8  QLA 2310F SG XPCI2FC QF4 SG XPCIEFCGBE E8  Emulex  SG XPCI1FC EM4 Z   LP982 LP9802  SG XPCI2FC EM4 Z   9802DC SG XPCIE2FCGBE Q Z   LP9002 LP9002DC  SG XPCIE2FCGBE E Z   LP952   LP10000 10000DC    LP1050   Lpe11000 LPe11002    LPe11
30. t information     Configuration  Firmware 01 29 06 00 IT with NVDATA 2DC5  BIOS 6 28 00 00   FCode 1 00 49     TABLE8 SAS 1 HBA Settings       Host OS Settings   Solaris 10u9  SPARC HBA defaults   Solaris 10u9  x86 IODeviceMissingDelay 20  ReportDeviceMissingDelay 20   Oracle Linux 5 8  5 7  5 6  5 5 IODeviceMissingDelay 8   RHEL 5 8  5 7  5 6  5 5 ReportDeviceMissingDelay 144   Oracle Linux 6 3  6 2  6 1  6 0 IODeviceMissingDelay 8   RHEL 6 3  6 2  6 1  6 0 ReportDeviceMissingDelay 144       Supported FC and Multilayer Switches    The following FC fabric and multilayer switches are compatible for connecting data  hosts and the Sun Storage 2540 M2 array  See the release notes for your switch  hardware for firmware support information     m Brocade SilkWorm 200E 300 4100 4900 5000 5100 5300 7500 48000 DCX  m Cisco 9124 9134 9216 9216i 9222i 9506 9509 9513  m OLogic SANBox 5602 9000    Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 9       Expansion Tray Specifications    The following information updates the specifications published in the Sun Storage  2500 M2 Arrays Site Preparation Guide     TABLE2 Physical Specifications       Expansion Tray Height Width Depth Weight   Maximum       2501 M2 3 4   8 64 cm  19   48 26 cm  21 75   55 25 cm  59 52 Ib  27 kg        TABLE3 Maximum Power and Cooling Expansion Tray Specifications    Expansion Tray KVA Watts  AC  BTU Hr       2501 M2 0 276 276 945          ALUA TPGS with VMware    The following procedures des
31. t ses affili  s  d  clinent toute responsabilit   quant aux dommages caus  s par l utilisation de ce logiciel ou mat  riel pour ce type d applications     Oracle et Java sont des marques d  pos  es d Oracle Corporation et ou de ses affili  s  Tout autre nom mentionn   peut correspondre    des marques  appartenant    d autres propri  taires qu Oracle     Intel et Intel Xeon sont des marques ou des marques d  pos  es d Intel Corporation  Toutes les marques SPARC sont utilis  es sous licence et sont des  marques ou des marques d  pos  es de SPARC International  Inc  AMD  Opteron  le logo AMD et le logo AMD Opteron sont des marques ou des marques  d  pos  es d Advanced Micro Devices  UNIX est une marque d  pos  e d The Open Group     Ce logiciel ou mat  riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc  s    des contenus  des produits et  des services   manant de tiers  Oracle Corporation et ses affili  s d  clinent toute responsabilit   ou garantie expresse quant aux contenus  produits ou  services   manant de tiers  En aucun cas  Oracle Corporation et ses affili  s ne sauraient   tre tenus pour responsables des pertes subies  des co  ts  occasionn  s ou des dommages caus  s par l acc  s    des contenus  produits ou services tiers  ou    leur utilisation      5 cx Ca    Adobe PostScript    oun Storage 2500 M2 Arrays  Hardware Release Notes  October  2013 Update    This document contains important release information about Oracle 
32. ubsequently be brought online     Workaround    To avoid this problem  reduce the number of volumes mapped to host with the  affected version of Oracle Linux  You can map additional volumes to the host after it  boots     When Over 128 Volumes are Mapped to a Host  Paths to  Only the First 128 Volumes are Restored after the  Controller is Reset    Operating System  m Oracle Linux 5 8 with UEK kernel release 2 6 32 300 10 1 el5uek    Hardware Software Firmware    18 Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update   October 2013    m All controllers    m Controller firmware release 7 84  Problem or Restriction    This problem occurs when you have more than 128 volumes mapped to a host  both  controllers reboot  and only one controller comes back online  Only the first 128  volumes mapped to the host are accessible to the host for input output  I O   operations after the reboot  During the controller reboot  there might be a delay  before any of the volumes are accessible to the host  I O timeouts occur when the  host tries to communicate with the inaccessible volumes     Workaround    You can avoid this problem by mapping no more that 128 volumes to a host with the  affected operating system release  If the problem occurs  run the multipath  command again after the controller comes back online     Tasks Aborts Are Logged During a Controller Firmware  Upgrade    Operating System  m Red Hat Linux 6 2    m SuSe Enterprise Linux 11 2    Hardware Software  Fir
33. ucts  and services from third parties  Oracle  Corporation and its affiliates are not S for and expressly disclaim all warranties of any kind with reaped to third party content  products  and  services  Oracle Corporation and its affiliates will not be responsible for any loss  costs  or damages incurred due to your access to or use of third party  content  products  or services        Copyright    2011  2013 Oracle et ou ses affili  s  Tous droits r  serv  s     Ce logiciel et la documentation qui Pompeu sont pres par les lois sur la propri  t   intellectuelle  Ils sont conc  d  s sous licence et soumis    des   restrictions d utilisation et de divulgation  Sauf disposition de votre contrat de licence ou de la loi  vous ne pouvez pas copier  reproduire  traduire    diffuser  modifier  breveter  transmettre  distribuer  exposer  ex  cuter  publier ou afficher le logiciel  m  me partiellement  sous quelque forme et par   quelque roc  d   que ce soit  Par ailleurs  il est interdit de proc  der    toute ing  nierie inverse du logiciel  de le d  sassembler ou dele d  compiler  except       es fins d interop  rabilit   avec des logiciels tiers ou tel que prescrit par la loi     Les informations fournies dans ce document sont susceptibles de modification sans pr  avis  Par ailleurs  Oracle Corporation ne garantit pas qu elles  soient exemptes d erreurs et vous invite  le cas   ch  ant     lui en faire part par   crit     Si ce logiciel  ou la documentation qui l accompagne  est con
34. urces in the cluster to a level so that there is an overabundance of resources  the  HA service still reports that there are not enough and therefore no available host in  the cluster on which to run the secondary VM  After the VM fails completely   however  the VM can be restarted and put into Fault Tolerance mode again     Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 27    The shutdown of the VM is something that always happens if a Fault Tolerance  enabled VM is running unprotected without a linked secondary VM and the host on  which the primary VM is running fails for any reason  The failure of the secondary  VM in a node failure scenario for Solaris 10 guests can be regularly reproduced     When a node failure happens  the customer sees that Solaris 10 guests can have  issues restoring a secondary VM for Fault Tolerance enabled VMs  This is seen by  reviewing the vSphere client in the cluster VM view as well as in the event log for  the VM     Workaround    In most cases  the customer can correct the problem by performing one of the  following actions in the order shown  Perform one action and if that does not work   proceed to the next until the problem is resolved     1  Disable and re enable fault tolerance on the affected VM   2  Turn off fault tolerance for the VM altogether and turn it back on   3  Attempt to live vMotion the VM and try action 1 and action 2 again     It is possible that either the host CPU model is not compatible with tur
35. ware 07 84 44 10  VMWARE   host type will have  the ALUA and TPGS bits enabled by default     5  Perform a manual re scan and verify from the ESX host that the TPGS ALUA  enabled devices are claimed by the VMW SATP ALUA plug in   To confirm that the host is using the ALUA plugin   m ESX 4 1    a  Run the command    esxcli nmp device list   b  The value for Storage Array Type should be  VMW_SATP_ALUA  on every  device from the array with firmware 07 84 44 10  or later  installed  On arrays    with firmware previous to 07 84 44 10  the value should be   VMW SATP _ LSI      m ESXi 5 0    a  Run the command      esxcli storage nmp device list    b  The value for Storage Array Type should be  VMW SATP ALUA  on every  device from the array with firmware 07 84 44 10  or later  installed  On arrays  with firmware previous to 07 84 44 10  the value should be   VMW SATP LSI         Notable Fixes    For a list of bug fixes  see the latest firmware patch README file        Restrictions and Known Issues    The following are restrictions and known issues applicable to this product release   m  Restrictions  on page 14  m  Controller Issues  on page 14    m  Documentation Bugs  on page 28    Sun Storage 2500 M2 Arrays Hardware Release Notes  October 2013 Update 13    Restrictions    Single Path Data Connections    In a single path data connection  a group of heterogeneous servers is connected to an  array through a single connection  Although this connection is technically possible   there 
    
Download Pdf Manuals
 
 
    