Home

Instruction Manual - Best Dehumidifier Reviews

image

Contents

1. room humidity level 7 FAN speed indicator Eu high speed v low speed Operation 1 Plug unit into a correct main socket Please refer to the rating label at rear of the unit 2 Press ON OFF button to turn on the unit The compressor will start to work in continuous mode 3 Press HUMIDITY button to set the desired room humidity continuous de humidifying 50 60 70 or 80 4 Press the SPEED button to choose high or low fan 5 Toset timer press the TIMER button until desired hours of operation is indicated on display window One press equals one hour 6 Totum on TiO2AV light press the TiO2 UV button SD 46T only 7 To turn off the unit press ON OFF button again 8 The direction of the air outlet can be adjusted manually Drainage When ine water tank becomes full the Compressor will stop and of Water full indication will flash e The unit will beep To stop the beeping press the ON OFF button to turn unit off e The water full indicator will turn from blue light to red light Note during operation the water full indicator displays a blue light this is normal and part of the design of this unit When water tank becomes full the light turns red as a warning signal To empty the water tank pull out gently by using the handle on the water tank After emptying the tank place the water tank back in place Make sure it is properly positioned NOTE if the water tank is not positioned correctly
2. the unit CLEANING THE BODY Use soft cloth to wipe the unit clean Do not ever use volatile chemicals gasoline detergents chemically treated clothes or other cleansing solutions These all could possibly hurt the cabinet CLEANING THE FILTER For washable filter Tap the filter lightly or use a vacuum cleaner to remove excess dirt If the filter is particularly dirty wash with warm water and small amount of gentle detergent Allow to dry completely For active carbon filter This filter is not washable Its life span is variable and depends on the ambient conditions where the appliance is used The filter should be checked periodically about every 6 months and replaced if necessary To order carbon filters please call 1 800 330 0388 or visit www spt usa com Active Filter frame Washable carbon filter filter Grille 10 STORAGE If unit will not be used for an extended period of time please Turn unit off unplug from power source and secure power cord Empty water tank and allow to dry completely e Coverthe unit and store in cool area away from direct sunlight 11 Trouble shooting THE UNIT DOES NOT OPERATE e Is the unit plugged in e s the house electricity on e Is the room temperature below 41 F 5 C or above 95 F 35 C If so then it is out of the working temperature range of the unit e Make sure the humidistat or ON OFF switch is turned on e Check if wa
3. the water full indicator will remain red and unit will beep p c If the water tank is full TAA or not correctly positioned the water indicator will turn from blue to red light To remove the water tank pull out gently from the unit by using the handle on the water tank Continuous drainage When the dehumidifier is operated in very high humidity climates the water tank will require more frequent drainage In this situation it may be more convenient to set up the unit for continuous drainage by following these procedures 1 Tum unit OFF and unplug power source 2 Use a screwdriver and remove the round knockout at the back of the unit FIG 1 CAUTION When the knockout is removed this will leave a hole in the housing Do not cover the opening with any type of plug If the opening is blocked water will not be able to flow out and cause possible malfunction to the unit 3 Connect the drain spout with a water tube of 12 mm inner diameter FIG 2 Note water tube is not supplied with the unit 4 Please make sure the tube is securely connected with no sharp bends or kinks Note In very cold weather conditions precautions should be taken to prevent the water tube from freezing FIG 1 ater tube with inner diameter lof 12 mm Note the tube is not supplied with the unit Maintenance Always unplug the unit from the main power supply before cleaning or maintaining
4. Dehumidifier Instruction Manual fer SD 46 SD 46T with TiOZ UV 50 60 70 80 Tt O Please read and retain these instructions for future reference Please take time to read this manual carefully before use and save it for future reference Page Model no reference Specification 2 How it works 3 Where to position 3 Before use 4 Parts 5 Operation 6 7 Drainage 8 9 Maintenance 10 11 Trouble shooting 12 Warranty Info 13 Model no Reference SD 46 46 Pints day dehumidifier SD 46T 46 Pints day dehumidifier with TiO2 UV Specification Model no SD 46 SD A6T Power supply 115V 60Hz Moisture removal capacity 46 Pints day Power Amp consumption 440W 4A Compressor Retigerant Working range Water tank capacity Szo Wit e Above is measured under RT 86 F 30 C RH 80 e The data marked with may vary for technical reasons For greater precision please refer to the rating label placed on the product D Dy Li DRY WARMER AIR X FAN A A E N MOTOR CLM MICRO SWITCH WATER TANK CONDENSER EVAPORATER n MOIST SATURATED AIR COMPRESSOR This product is a dehumidifier It controls relative humidity by passing the air through the unit forcing the excess moisture to condensate over the cooling elements Contact with this cold surface causes the moisture in the air to con
5. dense This condensed water then drains safely into the water tank The dried air then passes through the condenser where it is slightly warmed and re enters the room at a slightly elevated temperature Where to position Excess moisture will travel throughout your home in the same way that cooking smells waft to every room in the house For this reason the dehumidifier should be positioned so that it can draw this moist air towards it from all over the home Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier close to this area and later moving it to a more central point When positioning the dehumidifier ensure that it is placed on a level surface and with a minimum of 10 cm 4 of space on either side of the unit to allow for efficient airflow This dehumidifier is fitted with castors for extra mobility If you move the unit it should first be switched off and the water tank emptied We do not recommend the use of an extension cord so please try to ensure that the unit is sufficiently close to a fixed main socket If it is necessary to use an extension cord please ensure the diameter of the extension cable is at least 1 mr When the dehumidifier is in operation outside doors and windows should be closed for most efficient use Before use Caution Always keep the unit in vertical position Leave the unit to stand for at least an hour after t
6. l damage caused by possible defects with this product e Damage to product caused by improper power supply voltage accident fire floods or acts of nature e Failure of product resulting from unauthorized modifications to the product e Improper installation or failure to perform the necessary maintenance This GUARANTEE is in addition to your Statutory Rights SUNPENTOWN INTERNATIONAL INC 21415 Baker Parkway City of Industry CA 91789 5236 909 468 5288 Fax 909 468 5279 service sunpentown com www sunpentown com
7. only 4 Speed ventilation button 2 Timer 5 Hurnidity selection button 3 Display window 6 ON OFF button Display window L 50 60 70 eol 1 Humidity display C continuous de hurnidifying 50 60 70 or 80 ue ped a M 2 Ambient humidity condition good Tr z poor 4 loodi Ambient room humidity is between 50 to 70 A LT toi Ambient room humidity is between 3096 to 50 or 70 to 80 Aa ZNN Poor Ambient room humidity is higher than 80 o a Compressor is in progress When unit is de frosting the water drops will 3 flash sl Compressor is not in progress a cub I water tankis tul 4 UV ultraviolet indicator indicates that the TiO2 uv function is in operation When a Photo Catalyst titanium dioxide TiO2 captures UL traviolet light UV activated oxygen is formed from water or oxygen in the air Similar to the process of photosynthesis in green plants where chlorophyll captures sunlight and turns water and carbon dioxide into oxygen and glucose The formed activated oxygen has a high oxidization power that is strong enough to oxidize and decompose viruses organic materials odor and bacteria SD 46T with this technology has made it possible to have advanced functions including sterilizing deodorizing and anti fouling properties Model SD 46T only 5 TIMER indicator sets timed operation from 1 to 24 hours 6 HUMIDITY level indicator displays the ambient
8. ransport or when it has been tilted e g during cleaning before connecting to the main supply Keep all foreign objects away from the air intake or output openings The main supply must conform to the specification shown on the rating plate at the back of the unit If the supply cord is damaged it must be replaced by an approved service technician or one similarly qualified Never use the plug to start or stop the unit Always use the power switch on the control panel Before moving the unit first switch off unplug and empty the water tank Do not use bug sprays or other flammable cleaners on the unit Never pour or spray water over the unit IMPORTANT Do not use this unit at ambient temperatures below 41 F to prevent the possibility of evaporating coils from icing Front Control panel l Cover for air outlet 2 Air outlet Water full indica Water tank Handle 3 tor 4 5 8 Rear Air filter air inlet 7 Power cord Handle 10 Spout for continuous 8 9 drainage Water tank Caster 11 12 Iters Assembly of the f Active Filter frame 66 PPP RRVVVNVVNYY Ry RRR RRI RR RR RRR XM BRS BRN QA RRR PRRI GS RRI carbon filter filter Washable Grille Control panel 7 o2lUY sow 60 70 80 e EE 12 3 A456 1 Tio2 uv button SD 46T
9. ter tank is positioned correctly and tank is not full e Make sure the air inlet and outlet are not obstructed THE UNIT SEEMS TO DO NOTHING e sthe filter dusty or contaminated e Is the air intake or outlet blocked e sthe room humidity already quite low THE UNIT SEEMS TO DO LITTLE e Are too many windows or doors open e Is there something in the room producing lots of humidity THE UNIT IS TOO NOISY e Check whether the unit is sitting on a leveled surface THE UNIT IS LEAKING e Make sure the unit is in good shape e f you are using continuous drainage make sure the tube is securely connected 12 SPT Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired free of charge This guarantee is subject to the following terms e Sunpentown must be notified of the fault e Proof of purchase must be presented to Sunpentown s nominated representative e The warranty will be void if the product if modified misused or repaired by an unauthorized person e The warranty after repair will not be extended beyond the original one year period e All replacement parts will be new or reconditioned e Parts which are replaced become the property of Sunpentown e The warranty applies for the use of the product in the USA only What is NOT COVERED e Warranty does not include freight charges e Incidental or consequentia