Home
Oracle Integrated Lights Out Manager 3.0 Supplement for the Sun
Contents
1. At the gt prompt type gt set SYS keyswitch_state value where value can be m normal The system can power itself on and start the boot process the default m standby The system cannot power itself on m diag The system can power itself on using preset values of diagnostic properties HOST diag level max HOST diag mode max HOST diag verbosity max to provide thorough fault coverage This option overrides the values of diagnostic properties that you might have set 37 m locked The system can power itself on however you are prohibited from updating any of the flash devices or setting HOST send_break_action break V Control the Virtual Keyswitch Web Interface You can use the web interface to control the virtual keyswitch position of the system System System Power User Remote PTE Information Monitoring Management Configuration Management Control Redirection KVMS Remote Power Control Diagnostics Host Control Host Boot Mode Keyswitch TPM Keyswitch Configure keyswitch Keyswitch Normal xj Save einen 1 Log in to the ILOM web interface as Administrator root to open the web interface 2 Select Remote Control gt Keyswitch 3 Select the Keyswitch state value 4 Click Save 38 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Using the Remote Console ILOM Remote Console is a Java application that enables you to remotely re
2. 70 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Event Messages Available Through the ALOM Compatibility Shell This chapter contains information about event messages Topics include m Event Message Overview on page 71 m Event Severity Levels on page 72 m Service Processor Usage Event Messages on page 72 m Environmental Monitoring Event Messages on page 75 m Host Monitoring Event Messages on page 78 Event Message Overview The firmware on the service processor known in ALOM CMT as the SC or system controller sends event messages to several destinations m Messages are sent to all logged in users based on the configuration of the sc_clieventlevelvariable m Messages are recorded in the event log View logged messages using the ALOM compatibility shell showlogs command m Messages recorded in the event log can be identified according to the severity of the event If the severity of the event is major or critical you can view the messages for those events using the ALOM compatibility shell showlogs p r command View all messages in the event log using the ALOM compatibility shell showlogs p p command m Messages are sent in email messages based on the configuration of the mgt_mailalert variable Individual email addresses can be configured to receive messages of different severities m If the event represents a fault the event message appears in the output
3. ALOM CMT Variable Comparable ILOM Properties diag_level diag_mode diag_trigger diag_verbosity if_connection if_emailalerts if_network mgt_mailalert mgt_mailhost netsc_dhcp netsc_commit netsc_enetaddr netsc_ipaddr netsc_ipgateway netsc_ipnetmask sc_backupuserdata sc_clieventlevel HOS1 HOS1 HOS1 HOS1 S S S S S S S S S S S S P networ P networ P networ P networ P networ P networ N A K K K K K K r diag level r diag mode diag trigger diag verbosity P services ssh state P clients smtp state P network state P alertmgmt rules P clients smtp address pendingipdiscovery commitpending macaddress pendingipaddress pendingipgateway pendingipnetmask P policy BACKUP_USER_DATA 69 TABLE ALOM CMT Variables and Comparable ILOM Properties Continued ALOM CMT Variable Comparable ILOM Properties sc_cliprompt N A sc_clitimeout N A sc_clipasswdecho N A sc_customerinfo SP system_identifier sc_escapechars SP console escapechars sc_powerondelay SP policy HOST_POWER_ON_DELAY sc_powerstatememory SP policy HOST_LAST_POWER_STATE ser_baudrate SP serial external pendingspeed ser_data N A sys_autorestart SP autorestart sys_autorunonerror SP autorunonerror sys_boottimeout HOST boottimeout sys_bootrestart HOST bootrestart sys_bootfailrecovery HOST bootfailrecovery sys_eventlevel N A sys_enetaddr HOST macaddress
4. Change Customer FRU Data CLI on page 18 Change System Identification Information CLI on page 18 Change Customer Identification Information Web Interface on page 19 Reset Service Processor Settings to Factory Default Values CLI on page 20 Reset Service Processor Settings to Factory Default Values Web Interface on page 21 Display Console History CLI on page 21 Change Console Escape Characters CLI on page 22 Specify Backup of the User Database CLI on page 23 Restore Host Power State at Restart CLI on page 24 Specify Host Power State at Restart CLI on page 24 Disable or Re Enable Power On Delay CLI on page 25 Manage Configuration Policy Settings Web Interface on page 25 Disable or Re Enable Network Access to the SP CLI on page 32 Display the DHCP Server s IP Address CLI on page 32 17 Storing Customer Information This section describes ILOM features that enable you to store information for purposes such as inventory control or site resource management on the SP and FRU PROMs m Change Customer FRU Data CLI on page 18 m Change System Identification Information CLD on page 18 m Change Customer Identification Information Web Interface on page 19 V Change Customer FRU Data CLI Use the SP customer_frudata property to store information in all FRU PROMs At the gt prom
5. The default value is normal V Specify Diagnostic Trigger Conditions CLI Use the HOST diag trigger property to control the conditions under which POST runs if diagnostics are enabled At the gt prompt type gt set HOST diag trigger value where value is one or a combination supplied within quote marks and separated by a space of the following user reset Run diagnostics when the system is reset error reset Run diagnostics when the system takes a fatal error that requires the system to reset itself to recover power on reset Run diagnostics when the system is powered on all resets Run diagnostics at any server reset Managing the Host 13 m none Skip diagnostics The default value is the combination of power on reset error reset For example gt set HOST diag trigger user reset power on reset Set trigger to user reset power on reset gt show HOST diag trigger Properties trigger user reset power on reset Commands set show Y Choose the Amount of Verbosity in Diagnostic Output CLI Use the HOST diag verbosity property to specify the verbosity level of the output from POST diagnostics if diagnostics are enabled At the gt prompt type gt set HOST diag verbosity value where value is one of the following m none Diagnostics do not print any output on the system console when running unless a fault is detected m
6. on page 6 Display Host s Boot Mode Expiration Date CLI on page 7 View or Configure Boot Mode Settings Web Interface on page 7 Display the Host s MAC Address CLI on page 8 Display the Host s OpenBoot Version CLI on page 9 Display the Host s POST Version CLI on page 9 Specify Host Behavior When the Host Stops Running CLI on page 10 Specify Host Behavior When an Error Is Discovered During Diagnostics CLI on page 9 Specify Host Behavior When an Error Is Discovered During Diagnostics CLI on page 9 View and Configure Host Control Information Web Interface on page 10 Enable the System to Send a Break Signal or Force a Core Dump CLI on page 16 Display Host Status Information CLI on page 16 Resetting the Host The reset command generates a graceful or forced hardware reset of the host server By default the reset command gracefully resets the host If a graceful reset is not possible a forced reset is performed For a list of available options for the reset command in both the ILOM and ALOM compatibility CLIs see ALOM CMT Shell Status and Control Commands on page 64 Managing Host Boot Mode Use the boot mode properties to specify how ILOM handles boot m Boot Mode on page 4 m Manage the Host Boot Mode LDoms Configuration CLI on page 5 m Manage the Host Boot Mode Script CLI on page 6 m Change the Hos
7. property 24 SP policy HOST_POWER_ON_DELAY property 25 SYS keyswitch_state property 37 A ALOM CMT commands comparison with ILOM commands 58 ALOM CMT compatibility shell commands compared with ILOM commands 58 creating 55 limits to backward compatibility 53 ALOM CMT variables to commit 54 B backing up user data 23 boot mode managing configuration 5 managing reset 5 managing script 6 C commit network configuration properties 54 H host status information displaying with CLI 15 16 l ILOM commands compared with ALOM CMT compatibility shell commands 58 ILOM properties HOST autorestart 10 HOST autorunonerror 9 HOST macaddress 8 HOST send_break_action 12 16 OST status 15 16 HOST bootmode config 5 HOST bootmode expires 7 HOST bootmode script 6 HOST bootmode state 5 SP system_identifier 18 SP console escapechars 22 SP policy BACKUP_USER_DATA 23 SP policy HOST_AUTO_POWER_ON 24 SP policy HOST_LAST POWER STATE 24 SP policy HOST_POWER_ON_DELAY 25 SYS keyswitch_state 37 SP serial external commitpending 54 to commit 54 IPMI indicators 51 IPMI sensors 48 nn nnnm I 85 N network configuration properties to commit 54 0 OpenBoot version displaying with CLI 9 with web interface 10 P platform showing 15 16 POST version displaying with web interface 10 property
8. create SP users admin role aucro cli_mode alom Creating user Enter new password x Enter new password again Created SP users admin 3 Log out of the root account after you have finished creating the admin account gt exit 56 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 4 Log in to the ALOM CLI shell indicated by the sc gt prompt from the ILOM login prompt XXXXXXXXXXXXXXXXX login admin Password Waiting for daemons to initialize Daemons ready Integrated Lights Out Manager Version 3 0 x x Copyright 2008 Sun Microsystems Inc All rights reserved Use is subject to license terms sc gt In the ALOM CMT compatibility shell with a few exceptions you can use commands that resemble the commands of ALOM CMT The ALOM CMT compatibility shell is an ILOM interface The comparisons between the ILOM CLI and the ALOM CMT compatibility CLI are described in Comparing ILOM and ALOM CMT Commands on page 58 YV Switch Between the ALOM CMT Shell and the Host Console 1 To switch from the ALOM CMT shell to the host console type SC gt console host gt 2 To switch from the console to the ALOM CMT shell type hash period ost gt sc gt ALOM CMT Compatibility Shell 57 V Return to the ILOM From the ILOM CMT Shell 1 Log out of the ALOM CMT compatibility shell The ILOM prompt is displayed 2 L
9. gt Power Management 3 View the Actual Power consumption 4 View the Permitted Power consumption 5 View the Available Power 6 Select the Power Control 7 Select the Power Policy Managing the Service Processor 31 Note Elastic and Regulated policy values are not supported currently 32 Managing Network Access This section describes managing network access to the SP using ILOM a Disable or Re Enable Network Access to the SP CLI on page 32 a Display the DHCP Server s IP Address CLI on page 32 Disable or Re Enable Network Access to the SP CLI Use the SP network state property to enable or disable the service processor s network interface At the gt prompt type gt set SP network state value where value can be m enabled the default m disabled Display the DHCP Server s IP Address CLI To display the IP address of the DHCP server that provided the dynamic IP address requested by the service processor view the dhcp_server_ip property To see the dhcp_server_ip property use the following procedure Type gt show SP network SP network Targets Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Properties commitpending Cannot show property dhcp_server_ip 10 8 31 5 ipaddress 10 8 31 188 ipdiscovery dhcp ipgateway 10 8 31 248 ipnetmask 255 255 252 0 macaddress 00 14 4F 7
10. gt set HOST bootmode config configname where the config property takes a configname value such as a named logical domain configuration downloaded to the SP using the Logical Domains software For example if you have created a logical domain configuration called ldm set1 gt set bootmode config ldm set1 To return the boot mode config to the factory default configuration specify factory default For example gt set bootmode config factory default Note If you set HOST bootmode config ILOM sets the config to empty Change the Host Boot Mode Behavior at Reset CLI The HOST bootmode state property controls how OpenBoot nonvolatile random access memory NVRAM variables are used Normally the current settings of these variables are retained Setting HOST bootmode state reset_nvram changes the OpenBoot NVRAM variables to their default settings at the next reset Managing the Host 5 At the gt prompt type gt set HOST bootmode script value where value is one of the following m normal At next reset retains current NVRAM variable settings a reset_nvram At next reset returns OpenBoot variables to default settings Note state reset_nvram will return to normal after the next server reset or 10 minutes see expires property in Display Host s Boot Mode Expiration Date CLI on page 7 config and script properties do not expire and will be cleared
11. 1V1 MB CMPn V_ 1V5 MB CMPn V_ 1V8 MB CMPn I_ 1V1 MB CMPn 1I_ 1V5 SYS SLOTID SYS MB V_ V3_STBY SYS MB V 1VO SYS MB V 1V2 SYS MB V 5I0 SYS MB V 1V8 SYS MB V 3V3 SYS MB V 5V SYS MB V 12V SYSS MB 1 12V SYS SP V_BAT SYS VES SYS MB V_DDIO SYS MB CMPn V_ 1V1 SYS MB CMPn V_ 1 v5 SYS MB CMPn V_ 1V8 SYS MB CMPn I_ 1V1 SYS MB CMPn I_ 1V5 Identifier of the slot where the blade is installed 3 3V standby voltage threshold sensor MB voltage sensor MB voltage sensor MB voltage sensor MB voltage sensor MB voltage sensor MB voltage sensor MB voltage sensor MB 12V current sensor in Amps Battery voltage threshold sensor Real time blade power consumption in Watts I O voltage threshold sensor CMP 0 1 CPU core voltage sensor CMP 0 1 CPU core voltage sensor CMP 0 1 CPU core voltage sensor CMP 0 1 CPU current draw sensor in Amps CMP 0 1 CPU current draw sensor in Amps Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE IPMI Name Full Path Sensors on the Sun Blade T6340 Server Module Continued Description MB CMPn I_ 1V8 MB CMPn T_ 1V1 MB CMPn T_ 1V5 MB CMPn T_ 1V8 Pn BRn CHn Dn P MB Pn CBUS_BTn MB CMPn T_IN MB CMPn T_TCORE MB CMPn T_BCORE Pn BRn CHn Dn T_AMB HDDn PRSNT SYS MB CMPn I_ 1V8 SYS
12. and name of the FRU that was replaced This event can be received at SC boot or after FRUs have been swapped and the chassis cover is closed ALOM compatibility shell sends this message to indicate that the SC has detected a new FRU with pre existing faults logged into its FRU PROM This event can occur when either a FRU or the SC card is moved from one system to another The location is the name of the SEEPROM on the replaced FRU such as MB SEEPROM The most recent existing fault will be imported from the FRU PROM onto the showfaults list The entry on the showfaults list is the fault imported not this message Event Messages Available Through the ALOM Compatibility Shell 79 80 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 SCC Backup and Restore SPARC servers store in the SCC system configuration card a subset of the information backed up and restored by ILOM 3 0 In case of a server failure in which there is no ILOM backup of SP data transferring the SCC to the replacement server can provide partial restoration of the failed server s configuration data This chapter contains the following topic m Information Stored on the SCC on page 82 81 Information Stored on the SCC Note The version of the data on the SCC must match the version of the SCC daemon running on the SP If the versions differ the version on the SCC is ignored After SP reset the SCC data is overwrit
13. applied automatically powers on the host when the SP has been booted Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 m disabled Keeps the host power off when power is applied the default The default value is disabled Y Disable or Re Enable Power On Delay CLI Use the SP policy HOST_POWER_ON_DELAY property to cause the server to wait for a short time before powering on automatically The delay is a random interval of one to five seconds Delaying the server power on helps minimize current surges on the main power source This power on delay is important when multiple servers in racks power on after a power outage At the gt prompt type gt set SP policy HOST_POWER_ON_DELAY value where value can be m enabled m disabled the default The default value is disabled V Manage Configuration Policy Settings Web Interface Contiguration gen Alert Network ons Seral Clock Timezone og sure Policy ie Management Port oy Client Policy Configuration Configure system policies from this page To modify a policy select the radio button next to that policy then choose Enable or Disable from the Action drop down list Service Processor Policies Actions vj 4 Description Status f Auto power on host on boot enabling this policy disables Set host power to last power state policy Enabled C Set host power to last powe
14. automatically by POST discovering a fault or by a user typing the disablecomponent command component is the disabled component which will be an entry from the platform showcomponent command This fault event message appears in the output of the ALOM compatibility shell showfaults command ALOM compatibility shell sends this message when a component is enabled A component can be enabled by a user typing the enablecomponent command or by FRU replacement if the component itself is a FRU such as a DIMM component is the name of the component shown in the output of the platform showcomponent command Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE Host Monitoring Event Messages Continued Severity Message Description Major Host detected fault MSGID SUNW MSG ID Major Location has been replaced faults cleared Major Existing faults detected in FRU_PROM at location ALOM compatibility shell sends this message when the Solaris PSH software diagnoses a fault The SUNW MSG ID of the fault is an ASCII identifier that can be entered at http www sun com msg for more information about the nature of the fault and the steps to repair This fault event message appears in the output of the ALOM compatibility shell showfaults command ALOM compatibility shell sends this message after the replacement of a FRU that contained a host detected fault Location is the location
15. change the property The value is read and determined from the server s removable system configuration card SCC PROM and then stored as a property in ILOM HOST macaddress is the MAC address for the net0 port The MAC addresses for each additional port increments from the HOST macaddress For example net1 is equal to the value of HOST macaddress plus one 1 View the current setting for this property gt show HOST macaddress Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 V Display the Host s OpenBoot Version CLI The HOST obp_version property displays information about the version of OpenBoot on the host View the current setting for this property gt show HOST obp_version Vv Display the Host s POST Version CLI The HOST post_version property displays information about the version of POST on the host View the current setting for this property gt show HOST post_version V Specify Host Behavior When an Error Is Discovered During Diagnostics CLI Use the HOST autorunonerror property to specify whether the host should continue to boot after system diagnostics have discovered an error Set this property gt set HOST autorunonerror value where value can be m false The system stops booting after an error has been discovered the default m true The system attempts to continue booting after an error h
16. exemptes d erreurs et vous invite le cas ch ant lui en faire part par crit Si ce logiciel ou la documentation qui l accompagne est conc d sous licence au Gouvernement des Etats Unis ou toute entit qui d livre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats Unis la notice suivante s applique U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific supplemental regulations As such the use duplication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 3097 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 Ce logiciel ou mat riel a t d velopp pour un usage g n ral dans le cadre d applications de gestion des informations Ce logiciel ou mat riel n est pas con u ni n est destin tre utilis dans des applications a risque notamment dans des applications pouvant causer des dommages corporels Si vous utilisez ce logiciel ou mat riel dans le cadre d applications dangereuses il est d
17. mode to value reset_nvram reset_nvram with the bootmode command success Minor root Set object ALOM compatibility shell sends this message HOST bootmode script after a user changes the boot mode boot script value text success The boot script text is the text of the boot script provided by the user Minor Keyswitch position has ALOM compatibility shell sends this message been changed to after a user changes the keyswitch position with keyswitch_position the setkeyswitch command The keyswitch_position is the new keyswitch position Minor user open session ALOM compatibility shell sends this message object session type when users log in user is the name of the user value www shell who just logged in success Event Messages Available Through the ALOM Compatibility Shell 73 74 TABLE System Controller Usage Event Messages Continued Severit y Message Description Minor user close session ALOM compatibility shell sends this message object session type when users log out user is the name of the user value www shell who just logged out success Minor root Set object ALOM compatibility shell sends this message HOST send_break_action when an ALOM compatibility shell user sends a value dumpcore request to the host to dump core by typing the success break D command Critica Host Watchdog timeout ALOM compatibility shell sends this message 1 when the host watchdog has timed out and th
18. not use the Remote Serial Console and the ILOM ssh shell to administer Solaris If this happens and you want to switch back to the default operation you must reset both input device and output device to their default values See Resetting the Variables to the Defaults Using ILOM on page 44 Caution Be careful when setting OpenBoot input and output variables If you set the variables to devices that are not consistently available for example you will not be able to see output or type at the ok prompt when the devices are not available In this case you must reset the value of both variables to the default See Resetting the Variables to the Defaults Using ILOM on page 47 for more information At the OpenBoot ok prompt or in Solaris use one of the following procedures to change the input and output device settings V Configuring the Host at the OpenBoot Prompt 1 Establish a local connection to the default console on the server module Refer to the Sun Blade T6340 Server Module Installation and Administration Guide for information about establishing a local connection To use the default console the values of OpenBoot input device and output device variables must be set to the default value virtual console 2 Go to the OpenBoot ok prompt a If you see the ILOM prompt gt you are on the service processor not the system console Start the system console gt start SP console Are you sure you want to
19. number of different ways that you can connect to Oracle s Sun Blade T6340 Server Module to use the remote console as described in this figure FIGURE Connection Options for Sun Blade T6340 Server Modules Figure Legend 1 Server local or remote Computer connected to RJ 45 Ethernet remote ILOM Remote Console connections Ethernet cable connected to RJ 45 Ethernet connector on the chassis management module CMM NET MGMT 0 CMM with two connectors RJ 45 cable connected to CMM serial port SER MGT 10 Computer connected to CMM RJ 45 serial connector Computer connected to dongle cable RJ 45 serial connector Keyboard video monitor mouse local KVM Dongle cable with one RJ 45 serial two USB 2 connectors and one HD15 pin connector VGA Sun Blade T6340 Server Module with service processor SP 40 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Configuring the Host for Using Remote Console With OpenBoot To use OpenBoot with Remote Console you must set the OpenBoot environment variables input device and output device to appropriate values The default value for these variables is virtual console This virtual console value is the textual stream console that is sent to the ILOM SP You can change the OpenBoot input device and output device settings so that the ILOM SP textual console displays only the Power On Self Test POST output but not OpenBoot output the
20. of the ALOM compatibility shell showfaults command 71 m Messages are sent to the managed system operating system for logging into the Solaris syslog facility based on the configuration of the sys_eventlevel variable Not all versions of the Solaris Operating System support this capability Event Severity Levels Each event has a severity level and corresponding number m Critical 1 a Major 2 m Minor 3 ALOM compatibility shell configuration parameters use these severity levels to determine which event messages are displayed Service Processor Usage Event Messages The following table displays usage event messages from the service processor system controller TABLE Severit y System Controller Usage Event Messages Message Description Critica 1 Critica 1 Critica 1 Host has been powered off Host has been powered off Host has been powered off ALOM compatibility shell sends this message whenever the SC requests a host power off including when a user types the powerof f command ALOM compatibility shell sends this message when the SC requires an immediate host power off including when a user types the poweroff f command ALOM compatibility shell sends this message when the host power has turned off It is also normal for this event to be sent when the host has reset itself 72 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE S
21. platform hardware or the SC hardware The system should be manually unplugged to prevent damage to the platform hardware This fault event message appears in the output of the ALOM compatibility shell showfaults command ALOM compatibility shell sends these messages to indicate that a FRU has been removed or inserted The field FRU_type indicates the type of FRU such as SYS_FAN PSU or HDD The field location indicates the location and name of the FRU as shown in the output of the showenvironment command ALOM compatibility shell sends this message to indicate that a power supply is not receiving input power This message normally indicates that the power supply is not plugged in to AC power If the power cords are plugged in to an outlet that is provided power this message indicates a problem with the power supply itself This fault event message appears in the output of the ALOM compatibility shell showfaults command Event Messages Available Through the ALOM Compatibility Shell 77 78 Host Monitoring Event Messages The following table displays host monitoring event messages from the service processor system controller TABLE Host Monitoring Event Messages Severity Message Description Critical Minor SP detected fault at time time component disabled SP detected fault cleared at component reenabled ALOM compatibility shell sends this message when a component has been disabled either
22. start SP console y n y Serial console started To stop type If you see the ok prompt in the console go to Step 3 m If the Solaris OS is running either configure the host in Solaris OS or bring the OS down If Solaris OS is running you will see a Solaris prompt You can use the procedure To Configure the Host in Solaris on page 47 42 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 If you prefer to configure the host at the ok prompt you must bring down Solaris to access the ok prompt The preferred method of reaching the ok prompt is to shut down the operating system by typing an appropriate command for example the init or uadmin command as described in Solaris system administration documentation For example if you type init 0 at the Solaris prompt the system gradually takes you to the ok prompt 3 At the OpenBoot ok prompt type ok setenv output device rscreen ok setenv input device rkeyboard Note The rkeyboard and rscreen aliases are defined with appropriate parameters for a Sun Blade T6340 Server Module These aliases are not generally available or appropriate for all platforms 4 Activate the change by using the reset all command The console no longer provides input 5 Exit the console to return to the ILOM SP using the ILOM escape sequence ok The default ILOM escape sequence is hash period 6 Start the ILOM Remote V
23. upon the next server reset or manually by setting value to V Manage the Host Boot Mode Script CLI Atthe gt prompt type gt set HOST bootmode script value where script controls the host server OpenBoot PROM firmware method of booting script does not affect the current HOST bootmode setting value can be up to 64 bytes in length You can specify a HOST bootmode setting and set the script within the same command For example gt set HOST bootmode state reset_nvram script setenv diag switch true After the server resets and OpenBoot PROM reads the values stored in the script the OpenBoot PROM sets the OpenBoot PROM variable diag switch to the user requested value of true Note If you set HOST bootmode script ILOM sets the script to empty Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Vv Display Host s Boot Mode Expiration Date CLI At the gt prompt type gt show HOST bootmode expires Properties expires Thu Oct 16 18 24 16 2008 where expires is the date and time when the current boot mode will expire Vv View or Configure Boot Mode Settings Web Interface System System Power User Remote Configuration Maintenance _ Information Monitoring Management Management Control Remote Power Host Host Boot Redirection KVMS Control Diagnostics Control Mode Keyswitch TPM Host Boot Mode Settings Configure b
24. 1 chassis component sensors FMn PRSNT SYS FMn PRSNT FM 0 5 chassis component sensors FMn Fn TACH SYS FMn Fn TACH FM 0 5 tachometer in RPM for Fn where n 0 or a FMn SERVICE SYS FMn SERVICE FM 0 5 service sensor PSn VINOKn SYS PSn VINOKn PS 0 1 sensor for VINOKn where n 0 or 1 PSn PWROKn SYS PSn PWROKn PS 0 1 sensor for PWROKn where n 0 or 1 PSn FANOK SYS PSn FANOK PS 0 1 fan OK sensor PSn TEMPOK SYS PSn TEMPOK PS 0 1 temperature OK sensor PSn V12VOKRn SYS PSn V12VOKn PS 0 1 OK sensor for IV12VOKn where n 0 or 1 PSn 112VOKn PSn 112VOKn PS 0 1 OK sensor for V12VOKn where n 0 or 1 MB FEM PRSNT SYS MB FEM PRSNT FEM presence sensor MB FEM PRSNT SYS MB FEM PRSNT REM presence sensor Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Indicators on the Sun Blade T6340 Server Module TABLE Indicators on the Sun Blade T6340 Server Module Name Path Description SYS LOCATE SYS LOCATE Locate indicator SYS ACT SYS ACT System power activity indicator SYS SERVICE SYS SERVICE Service indicator HDDn SERVICE SYS HDDn SERVICE Hard disk drive 0 3 service indicator HDDn OK2RM SYS HDDn OK2RM Hard disk drive 0 3 OK to remove indicator SYS OK2RM SYS OK2RM Blade OK to remove indicator Pn BRn CHn Dn S SYS MB CMPn BRn CHn Dn SERVICE CMP 0 1 Branch 0 1 Channel 0 1 DIMM 0 3 Service indicator IPMI Sens
25. E 83 4F pendingipaddress 10 8 31 188 pendingipdiscovery dhcp pendingipgateway 10 8 31 248 pendingipnetmask 255 255 252 0 state enabled Commands cd set show Managing SSH Server Settings Changing the Type of SSH Keys CLI Changing the Type of SSH Keys CLI on page 33 Generating a New Set of SSH Keys CLI on page 34 Restarting the SSH Server CLI on page 34 Enable or Disable the SSH Service CLI on page 34 Managing SSH Server Settings Web Interface on page 34 Use the set SP services ssh generate_new_key_type command to change the type of Secure Shell SSH host keys generated on your server After changing the type you must use the command set SP services ssh generate_new_key_action to generate a new set of keys of the new type Atthe gt prompt type the following command gt set SP services ssh generate_new_key_type value where value can be rsa or dsa Managing the Service Processor 33 V Generating a New Set of SSH Keys CLI Use the set SP services ssh generate_new_key_action command to generate a new set of Secure Shell SSH host keys At the gt prompt type the following command gt set SP services ssh generate_new_key_action true V Restarting the SSH Server CLI Use the set SP services ssh restart_sshd_action command to restart the SSH server after you have generated new host keys using the set SP serv
26. Identifier field if desired 6 Edit the SP System Contact field if desired 7 Edit the SP System Location field if desired 8 View the SP System Description 9 Click Save Managing the Service Processor 19 Changing Service Processor Settings to Factory Defaults You can reset the service processor setting to factory defaults using the CLI or the web interface m Reset Service Processor Settings to Factory Default Values CLI on page 20 m Reset Service Processor Settings to Factory Default Values Web Interface on page 21 V Reset Service Processor Settings to Factory Default Values CLI Use the set reset_to_defaults command to set all ILOM configuration properties back to their factory default values The a11 option sets the ILOM configuration and all user information back to the factory default values 1 At the gt prompt type the following command gt set SP reset_to_default value Where value can be one of the following m none Make no changes m all Reset clear all configuration and users 2 Reset the service processor so that the new property value can take effect 20 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 V Reset Service Processor Settings to Factory Default Values Web Interface System System Power Configuration User Remote Se Information Management Management Control Firmware Upgrade BackupRestore Reset SP Configurati
27. MB CMPn T_ 1V1 SYS MB CMPn T_ 1V8 SYS MB CMPn T_ 1V8 SYS MB Pn BRn CHn Dn P SYS MB Pn CBUS_BTn SYS MB CMPn T_IN SYS MB CMPn T_TCORE SYS MB CMPn T_BCORE SYS MB Pn BRn CHn Dn T_ AMB SYS HDDn PRSNT CMP 0 1 CPU current draw sensor in Amps CMP 0 1 temperature sensor for voltage regulators in degrees Celsius CMP 0 1 temperature sensor for voltage regulators in degrees Celsius CMP 0 1 temperature sensor for voltage regulators in degrees Celsius CMP 0 1 DIMM presence sensors defined by branch BRn where n 0 or 1 channel CHn where n 0 or 1 and DIMM Dn where n is an integer 0 3 CMP 0 1 CPU corner bus test point for point CBUS_BTn where n is an integer 0 11 CMP 0 1 temperature leading into the CPU in degrees Celsius CMP 0 1 CPU temperature sensor at the top of the chip in degrees Celsius CMP 0 1 CPU temperature sensor at the bottom of the chip in degrees Celsius CMP 0 1 temperature sensor in degrees Celsius defined by branch BRn where n 0 or 1 channel CHn where n 0 or 1 and DIMM Dn where n is an integer 0 3 Hard disk drive 0 1 presence sensors IPMI Sensor Reference 49 50 TABLE Sensors on the Sun Blade T6340 Server Module Continued IPMI Name Full Path Description NEMn PRSNT SYS NEMn PRSNT Network Express Module NEM disk 0 1 presence sensors PSn PRSNT SYS PSn PRSNT PS 0
28. Oracle Integrated Lights Out Manager ILOM 3 0 Supplement for Sun Blade T6340 Server Modules NS 2 Sun Part No 820 7144 11 Appril 2010 Revision A Copyright 2009 2010 Oracle and or its affiliates All rights reserved This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws Except as expressly permitted in your license agreement or allowed by law you may not use copy reproduce translate broadcast modify license transmit distribute exhibit perform publish or display any part in any form or by any means Reverse engineering disassembly or decompilation of this software unless required by law for interoperability is prohibited The information contained herein is subject to change without notice and is not warranted to be error free If you find any errors please report them to us in writing If this is software or related software documentation that is delivered to the U S Government or anyone licensing it on behalf of the U S Government the following notice is applicable U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific supplemental regulations As such the use du
29. P powermgmt 4 SP powermgmt Targets Properties actual_power 206 permitted_power 420 allocated_power 420 available power 420 control local policy performance regulated_budget none elastic_budget none Commands cd set show where m actual_power displays the input power in watts consumed by all power supplies in the system m permitted_power displays the maximum power consumption in watts expected m available_power displays the input power capacity in watts that is available to system components V View the Total Power Consumed by the System CLI The value of SYS VPS is equivalent to the value of the show SYS powermgmt actual_power command 28 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 The SP powermgmt actual_power property is the same as SYS VPS in that SYS VPS is a sensor that has a threshold and actual_power is the value returned by the sensor At the gt prompt type the following command gt show SYS VPS for example gt show SYS VPS SYS VPS Targets Properties type Power Unit class Threshold Sensor value 200 Watts upper_nonrecov_threshold N A upper_critical_threshold N A upper_noncritical_threshold N A lower_noncritical_threshold N A lower_critical_threshold N A upper_nonrecov_threshold N A Commands cd show V Viewing Total Available Power CLI This interfa
30. Re Enable Network Access to the SP CLI 32 v Display the DHCP Server s IP Address CLI 32 Managing SSH Server Settings 33 v Changing the Type of SSH Keys CLI 33 v Generating a New Set of SSH Keys CLI 34 v Restarting the SSH Server CLI 34 v Enable or Disable the SSH Service CLI 34 v Managing SSH Server Settings Web Interface 34 Monitoring Active System Faults 35 v Displaying Active System Faults 35 Managing Devices 37 Managing Virtual Keyswitch Settings 37 v Specify Host Behavior CLI 37 v Control the Virtual Keyswitch Web Interface 38 Using the Remote Console 39 Contents vii Hardware Connection Options 40 Configuring the Host for Using Remote Console With OpenBoot 41 v Configuring the Host at the OpenBoot Prompt 42 v Configuring the Host in Solaris OS 44 Resetting the Variables to the Defaults Using ILOM 44 v Resetting the output device and input device Variables to Factory Default 45 Resetting All OpenBoot NVRAM Variable to Factory Defaults 45 Configuring the Host for Using Remote Console With Solaris OS 46 v Configuring the Host in Solaris OS 46 IPMI Sensor Reference 47 Sensors on the Sun Blade T6340 Server Module 48 Indicators on the Sun Blade T6340 Server Module 51 ALOM CMT Compatibility Shell 53 Limits to Backward Compatibility 53 Adding a Commit Step to Procedures That Configure ILOM Network Configuration Properties 53 v Commit a Change to a Network Configuration Property 54 v Commit a Chan
31. S on page 46 Vv Configuring the Host in Solaris OS You must set the remote video resolution The only remote video resolution supported is 1024x768x75 1 In Solaris become root then type fbconfig res 1024x768x75 2 Activate the change by logging out then logging back in 46 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 IPMI Sensor Reference Your server module includes a number of IPMI compliant sensors and indicators Sensors measure voltages temperature ranges and detection of when components are installed and removed Indicators such as light emitting diodes LEDs notify you of important server conditions such as when service is required The IPMI interface limits sensor names to 16 characters Sensor names must sometimes be shortened to fit this character limit For example SYS is sometimes removed from the beginning of the path or CMPO might be abbreviated to PO This chapter contains the following topics m Sensors on the Sun Blade T6340 Server Module on page 48 m Indicators on the Sun Blade T6340 Server Module on page 51 47 Sensors on the Sun Blade T6340 Server Module TABLE Sensors on the Sun Blade T6340 Server Module IPMI Name Full Path Description SYS SLOTID MB V_ V3_STBY MB V 1VO MB V 1V2 MB V 1V510 MB V 1V8 MB V 3V3 MB V 5V MB V 12V MB 1I 12V SP V_BAT SYS VES MB V_VDDIO MB CMPn V_
32. ables you to skip the confirmation question Turns off the OK to Remove LED and restores the service processor state stop script force SYS start script force SYS stop script force SYS start SYS set SYS LOCATE value value show SP faultmgmt set SYS component clear_fault_action true BJ show SYS LOCATI set SYS prepare_to_remove_action true set SYS return_to_service_action true 66 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 ALOM CMT Shell FRU Commands TABLE ALOM CMT Shell FRU Commands ALOM CMT Command Summary Comparable ILOM Command setfru c data The c option enables you to store set SYS customer_frudata information such as inventory codes data on all FRUs in a system showfru g lines s d Displays information about the FRUs show FRU FRU in a host server removefru y FRU Prepares a FRU for example a power set SYS PSO supply for removal The y option prepare_to_remove_action enables you to skip the confirmation true question ALOM CMT Shell Automatic System Recovery ASR Commands TABLE ALOM CMT Shell Automatic System Recovery ASR Commands ALOM CMT Command Summary Comparable ILOM Command enablecomponent Re enables a component that has set SYS component component been disabled using the component_state enabled disablecomponent command disablecomponent Disables a component component
33. age disabled when the SC refuses to power on the system either through the user poweron command or by the front panel power button The SC disables power on because of an accompanying event such as the event indicated by the message Chassis cover removed Other possibilities include a device failure or insufficient fan cooling Major System poweron is ALOM compatibility shell sends this message enabled after the condition that caused power on to be disabled indicated by the preceding System poweron is disabled message has been rectified For example by replacing the chassis cover or installing sufficient fans to cool the system Event Messages Available Through the ALOM Compatibility Shell 75 76 TABLE Environmental Monitoring Event Messages Continued Severit y Message Description Major SP detected fault at time ALOM compatibility shell sends this message time fault_type fault at when a failure or a fault is detected A fault is a location asserted lower priority condition that indicates the system is operating in a degraded mode fault_type is the type of failure that has occurred such as temperature voltage current or power supply The location is the location and name of the device that has the error condition The location and name of the device match the output of the ALOM compatibility shell showenvironment command This fault event message appears in the output of the ALOM compatibility sh
34. art_from end beginning default value is end ALOM CMT Compatibility Shell 63 ALOM CMT Shell Status and Control Commands TABLE ALOM CMT Shell Status and Control Commands ALOM CMT Command showenvironment showpower v shownetwork v console f break D c bootmode normal reset_nvram config configname bootscript string Summary Displays the environmental status of the host server This information includes system temperatures power supply status front panel LED status hard disk drive status fan status voltage and current sensor status Displays power metrics for the host server Displays the current network configuration information The v option shows additional information about your network including information about your DHCP server Connects to the host system console The f option forces the console write lock from one user to another In ILOM the force option terminates the console permitting you to start a new console Drops the host server from running the Solaris OS software into OpenBoot PROM or kmdb depending upon the mode in which the Solaris software was booted Controls the host server OpenBoot PROM firmware method of booting Comparable ILOM Command show o table level all SYS show SP powermgmt show SP network start force SP console set HOST send_break_action break dumpcore start SP console set HOST b
35. as been discovered The default value is false Managing the Host Vv Specify Host Behavior When the Host Stops Running CLI Use the HOST autorestartproperty to specify what ILOM should do when the host leaves the RUNNING state Set this property gt set HOST autorestart vwalue where value can be m none ILOM takes no action other than to issue a warning a reset ILOM attempts to reset the system when the Solaris watchdog timer expires the default a dumpcore ILOM attempts to force a core dump of the OS when the watchdog timer expires The default value is reset Y View and Configure Host Control Information Web Interface This procedure describes how to view and configure several kinds of host information 10 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Host Control View and configure the host contro information Auto Run on Error determines whether the host should continue to boot in the event of a non fatal POST error Auto Restart Policy determines what action the Service Processor should take when it discovers the host is hung Boot Timeout defines the time out value for boot timer 0 will disable the timer Boot Restart Policy defines boot timer restart action Max Boot Fails Allowed defines the number of max boot fails allowed Boot Fail Recovery defines the timer action upon reaching max boot fails MAC Address 00 14 4ted267a Hypervis
36. backup data 23 system user 12 15 R remote control settings changing with the CLI 4 changing with the web interface 7 S server platform information 15 16 SP serial external commitpending property 54 T timer watchdog 10 W watchdog timer 10 86 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010
37. ce enables you to view available power The system contains one property available_power The property supports the show command and returns the value lt input available power in watts gt Type the show command to display the available power For example gt show SYS powermgmt available_power Managing the Service Processor 29 V Monitoring Permitted Power Consumption CLI This interface enables you to view permitted power consumption The permitted power consumption is the maximum input power the server guarantees it will consume at any instant You cannot this value directly but you can change itbased on the power policy and budget and chassis available power The system contains one property permitted_power The property supports the show command and returns the value lt maximum permitted power consumption in watts gt Type the show command to display the permitted power consumption For example gt show SYS powermgmt available power Using the Power Consumption Control Interfaces The following section describes how to monitor and control available power and set power consumption configuration parameters This interface enables you to set and monitor the power policy of the system The power policy setting is saved across reboots The system contains one property policy This property supports the show and set commands Two power policies are supported performance and elastic The regula
38. cies using ILOM Specify Backup of the User Database CLI on page 23 Restore Host Power State at Restart CLI on page 24 Specify Host Power State at Restart CLI on page 24 Disable or Re Enable Power On Delay CLI on page 25 Manage Configuration Policy Settings Web Interface on page 25 Vv Specify Backup of the User Database CLI The SP policy BACKUP_USER_DATA property specifies whether the local user database on ILOM that is user password and permission information should be backed up When this property is set to enabled this data is backed up on the removable system configuration card SCC PROM on the system At the gt prompt type gt set SP policy BACKUP_USER_DATA value where value can be m enabled Backs up the user database to the SCC This is the default value m disabled No backup The default value is enabled For example if you want the local user database on ILOM to be backed up type gt set SP policy BACKUP USER _DATA enabled Managing the Service Processor 23 24 V Restore Host Power State at Restart CLI Use the SP policy HOST_LAST_POWER_STATE property to control the behavior of the server after an unexpected power outage When external power is restored the ILOM service processor starts to run automatically Normally the host power is not turned on until you use ILOM to turn it on ILOM records the current power state of
39. cify for an unlimited number of lines The default is all lines m pause_count This option accepts a value of 1 to any valid integer or for infinite number of lines The default is not to pause m start_from The options are a end The last line most recent in the buffer the default a beginning The first line in the buffer If you type the show SP console history command without having set any arguments with the set command ILOM displays all lines of the console log starting from the end Note Timestamps recorded in the console log reflect server time These timestamps reflect local time and the ILOM console log uses UTC Coordinated Universal Time The Solaris OS system time is independent of the ILOM time V Change Console Escape Characters CLI Use the SP console escapechars property to change the escape character sequence to switch from a system console session back to ILOM At the gt prompt type gt set SP console escapechars xx where xx can be any printable characters The sequence is limited to two characters The default value is Hash Period You can customize the sequence 22 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Note Changing the escape character does not take effect in a currently active console session Changing Configuration Policy Settings This section describes managing configuration system poli
40. direct and control the following devices on the host server Keyboard m Video console display m Serial console display Mouse device m Storage devices or images CD DVD This group of devices is commonly abbreviated as KVMS Remote Console is supported on the Sun Blade T6340 Server Module Connection by Remote Console corresponds with item 2 in the figure in Hardware Connection Options on page 40 For more information about connection options for your Sun Blade T6340 Server Module that are depicted in that figure refer to the Sun Blade T6340 Server Module Getting Started Guide and Sun Blade T6340 Server Module Installation and Administration Guide ILOM Remote Console is documented in the Oracle Integrated Lights Out Manager ILOM 3 0 Web Interface Procedures Guide Chapter 12 Managing Remote Hosts Much of the information in the guide is applicable for the Sun Blade T6340 Server Module This chapter describes differences in using Remote Console with a Sun Blade T6340 Server Module Before you can use Remote Console with a Sun Blade T6340 Server Module you must configure the host a If you want to work remotely with OpenBoot output and the ok prompt refer to Configuring the Host for Using Remote Console With OpenBoot on page 45 a If you want to work remotely with Solaris refer to Configuring the Host for Using Remote Console With Solaris on page 49 39 Hardware Connection Options There are a
41. e sys_autorestart variable has been set to none The SC will not perform any corrective measures Critica SP Request to Dump core ALOM compatibility shell sends this message 1 Host due to Watchdog when the host watchdog has timed out and the sys_autorestart variable has been set to dumpcore The SC attempts to perform a core dump of the host to capture error state information The dump core feature is not supported by all OS versions Critica SP Request to Reset Host ALOM compatibility shell sends this message 1 due to Watchdog when the host watchdog has timed out and the sys_autorestart variable has been set to reset Then the SC attempts to reset the host Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Environmental Monitoring Event Messages The following table displays environmental monitoring event messages from the service processor system controller TABLE Environmental Monitoring Event Messages Severit y Message Description Critica SP detected fault at time ALOM compatibility shell sends this message if 1 time Chassis cover the chassis cover has been removed The removed platform hardware turns managed system power off immediately as a precautionary measure The event message System poweron is disabled should accompany this message to prevent the use of the poweron command while the chassis cover is removed Major System poweron is ALOM compatibility shell sends this mess
42. e votre responsabilit de prendre toutes les mesures de secours de sauvegarde de redondance et autres mesures n cessaires son utilisation dans des conditions optimales de s curit Oracle me etses affili s d clinent toute responsabilit quant aux dommages caus s par l utilisation de ce logiciel ou mat riel pour ce type d applications Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses affili s Tout autre nom mentionn peut correspondre des marques appartenant d autres propri taires qu Oracle AMD Opteron le logo AMD et le logo AMD Opteron sont des marques ou des marques Re d Advanced Micro Devices Intel et Intel Xeon sont des marques ou des parques d pos es d Intel Corporation Toutes les marques SPARC sont utilis es sous licence et sont des marques ou des marques d pos es de SPARC International Inc UNIX est une marque d pos e conc d e sous licence par X Open Company Ltd Ce logiciel ou mat riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc s des contenus des produits et des services manant de tiers Oracle Corporation et ses affili s d clinent toute responsabilit ou garantie expresse quant aux contenus produits ou services manant de tiers En aucun cas Oracle Corporation et ses affili s ne sauraient tre tenus pour responsables des pertes subies des co ts occasionn s ou des dommages caus s par l acc s des co
43. ell showfaults command Minor SP detected fault cleared ALOM compatibility shell sends this message to at time time current fault indicate that a prior fault or failure has recovered at device asserted or been repaired The fields time and device are the same as the prior fault or failure event Major Device_type at location has ALOM compatibility shell sends these messages exceeded low warning when analog measurement sensors have threshold exceeded the specified threshold The threshold that was exceeded is included in Critica Device_type at location has LL 1 exceeded low critical shutdown threshold Device_type is the type of device that has failed such as VOLTAGE_SENSOR or TEMP_SENSOR The Critica Device_type at location has location is the location and name of the device l exceeded low that has the error condition The location and nonrecoverable shutdown name of the device match the output of the threshold ALOM compatibility shell showenvironment Major Device_type at location has command exceeded high warning For TEMP_SENSOR events this message could threshold indicate a problem outside of the server such as i f the temperature in the room or blocked airflow Critica Device_type at location has in or out of the server For VOLTAGE_SENSOR l exceeded high soft events this message indicates a problem with the CHA eles ee platform hardware or possibly with add on cards Critica Device_type at location has installed 1 exceeded
44. em and network administration Working with Logical Domains LDoms Using the Sun Blade 6000 or Sun Blade 6048 Modular System Title SunVTS User s Guide SunVTS Quick Reference Guide SunVTS Test Reference Manual Sun Management Center Software User s Guide Documentation online at http docs sun com app docs prod solaris 10 hic Documentation online at http docs sun com app docs prod ldoms m gr Documentation online at http docs sun com app docs prod blade 6 000mod http docs sun com app docs prod blade 6 048mod Documentation Support and Training These web sites provide additional resources Documentation http docs sun coem Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Support http www sun com support m Training http www sun com training Documentation Feedback Submit comments about this document by clicking the Feedback link at http docs sun com Include the title and part number of your document with your feedback Oracle Integrated Lights Out Manager 3 0 Supplement for the Sun Blade T6340 Server Module part number 820 7144 11 Using This Documentation xiii xiv Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Understanding ILOM for the Sun Blade T6340 Server Module This chapter introduces ILOM for the Sun Blade T6340 Server Module This chapter contains the following sect
45. erbose information about the displayed components Comparable ILOM Command set SP users username password set SP services ssh restart_sshd_action true set SP clock datetime value set SP reset_to_defaults none factory all1 set SYS keyswitch_state value set target property value No equivalent in ILOM show HOST 60 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE ALOM CMT Command Summary ALOM CMT Shell Configuration Commands Continued Comparable ILOM Command showfru showusers g lines showhost version showkeyswitch showsc param showdate ssh keygen 1 ssh keygen r ssh keygen t rsa dsa Displays information about the field replaceable units FRUs in a host server Displays a list of users currently logged in to ALOM CMT The display for this command has a similar format to that of the UNIX command who The g option pauses the display after the number of lines you specify for lines Displays version information for host side components The version option displays the same information as the showhost command with no option Displays status of virtual keyswitch Displays the current nonvolatile random access memory NVRAM configuration parameters Displays the ALOM CMT date ALOM CMT time is expressed in Coordinated Universal Time UTC rather than local time The Solaris OS and ALOM CMT time are not s
46. es of ILOM 3 0 that are common to all platforms This supplement is intended for experienced system administrators with knowledge of UNIX commands Related Documentation The documents listed as online are available at http docs sun com app docs prod blade t6340 hic Additional Sun documentation is available at http www sun com documentation Application Title Part Number Location Late breaking Sun Blade T6340 Server Module Product 821 3901 Online information Notes Getting started Sun Blade T6340 Server Module Getting 820 3899 Shipping kit Started Guide Online Safety information Sun Blade T6340 Server Module Safety 820 3903 Online and Compliance Manual xi Application Title Part Number Location Important Safety Information for Sun 816 7190 or Shipping kit Sun Hardware Systems 821 1590 Installing and Sun Blade T6340 Server Module 820 3900 Online administering the Installation and Administration Guide server module Service information Sun Blade T6340 Server Module Service 820 3902 Online Manual For more information about how to work with ILOM features that are common to all platforms managed by ILOM refer to the documentation at http docs sun com app docs prod blade t6320 ilom3 0 hic For more information about how to work with your host server the following documentation provides information Task Performing diagnostic tests Using the operating system for syst
47. g Commands TABLE ALOM CMT Shell Log Commands ALOM CMT Command showlogs p rlp b lines e lines v g lines consolehistory b lines e lines v g lines boot run Summary Displays the history of all events logged in the event log or major and critical events in the event log p selects whether to display only major and critical events from the event log r or to display all of the events from the event log p g lines specifies the number of lines to display before pausing e lines displays n lines from the end of the buffer b lines displays n lines from the beginning of the buffer v displays the entire buffer Displays the host server console output buffers g lines specifies the number of lines to display before pausing e lines displays n lines from the end of the buffer b lines displays n lines from the beginning of the buffer v displays the entire buffer Comparable ILOM Command show SP logs event list No equivalent in ILOM set SP console history property value set SP console history property value set SP console history property value show SP console history where property can be line_count lines default value is none meaning there is no limit to the total number of lines retrieved from the buffer pause_count count default value is none meaning there is no limit to the count of lines displayed per pause st
48. ge to a Serial Port Configuration Property 54 v Create an ALOM CMT Compatibility Shell 55 v Switch Between the ALOM CMT Shell and the Host Console 57 v Return to the ILOM From the ILOM CMT Shell 58 Comparing ILOM and ALOM CMT Commands 58 ALOM CMT Shell Configuration Commands 60 ALOM CMT Shell Log Commands 63 ALOM CMT Shell Status and Control Commands 64 ALOM CMT Shell FRU Commands 67 ALOM CMT Shell Automatic System Recovery ASR Commands 67 viii Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 ALOM CMT Shell Miscellaneous Commands 68 ALOM CMT Variables 69 ALOM CMT Variable Comparison 69 Event Messages Available Through the ALOM Compatibility Shell 71 Event Message Overview 71 Event Severity Levels 72 Service Processor Usage Event Messages 72 Environmental Monitoring Event Messages 75 Host Monitoring Event Messages 78 SCC Backup and Restore 81 Information Stored on the SCC 82 Index 85 Contents ix x Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Using This Documentation This supplement contains information about using the Sun Integrated Lights Out Manager ILOM firmware that runs the service processor SP of the Sun Blade T6340 Server Module from Oracle ILOM firmware is used to manage and administer the Sun Blade T6340 Server Module and other Oracle products The information in this supplement augments the set of documentation that covers featur
49. he variables to their default value virtual console After the variables have been reset you can access the prompts again from the default console Using ILOM you can reset only the output device and input device variables or you can reset all the OpenBoot NVRAM variables 44 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 V Resetting the output device and input device Variables to Factory Default To reset only the output device and input device environment variables to the default value you must use a bootmode script Refer to the section Managing Host Boot Mode on page 4 for general instructions 1 Reset the variables gt set HOST bootmode script set default input device set default output device 2 Power cycle the host gt stop SYS gt start SYS 3 At OpenBoot ensure that the host is up gt show HOST 4 Power cycle the host again The variables are now set to the default value virtual console and you can use the default console Resetting All OpenBoot NVRAM Variable to Factory Defaults Refer to the section Managing Host Boot Mode on page 4 for general instructions To reset the variables using the CLI follow the procedure Change the Host Boot Mode Behavior at Reset CLI on page 5 Using the Remote Console 45 Configuring the Host for Using Remote Console With Solaris OS m Configuring the Host in Solaris O
50. high hard These fault event messages appear in the output shutdown threshold of the ALOM compatibility shell showfaults command Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE Severit y Environmental Monitoring Event Messages Continued Message Description Minor Critica 1 Critica 1 Major Minor Major Device_type at location is within normal range Critical temperature value host should be shut down Host system failed to power off FRU_type at location has been removed FRU_type at location has been inserted Input power unavailable for PSU at location ALOM compatibility shell sends this message when an analog measurement sensor no longer exceeds any warning or failure thresholds This message is sent only if the sensor reading recovers sufficiently within the boundaries of the failure parameters The message might not match the current output of the ALOM compatibility shell showenvironment command ALOM compatibility shell sends this message to indicate that the SC has started a shutdown because there are not enough working fans necessary to keep the system cooled The number of fans necessary to maintain system cooling depends on the platform See your platform documentation for more information ALOM compatibility shell sends this message if the SC is unable to power off the system This message indicates a problem with either the
51. ices ssh generate_new_key_action command This reloads the keys into the server s dedicated data structure in memory At the gt prompt type the following command gt set SP services ssh restart_sshd_action true V Enable or Disable the SSH Service CLI Use the SP services ssh state property with the set command to enable or disable the SSH service If the SSH service has been disabled you can re enable it through the serial management port SER MGT using the ILOM web interface At the gt prompt type the following command gt set SP services ssh state value where value can be m enabled m disabled The default value is enabled V Managing SSH Server Settings Web Interface 1 Log in to the ILOM browser interface as Administrator root to open the web interface 34 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 2 Select Configuration gt SSH Server Settings 3 Select an action from the SSH Server pull down menu m Enable the SSH Server m Disable the SSH Server m Restart the SSH Server 4 Click Generate RSA Key or click Generate DSA Key to generate a new key type and a new key If you have generated a new key you must restart the SSH server for the new key to take effect Note When the SSH server is restarted or disabled any CLI sessions running over SSH will be terminated immediately Monitoring Active System Faults m Displaying Ac
52. ideo Console from the browser interface See Configuring ILOM for Remote Management on page 49 for more information 7 When you want to stop using Remote Console change the values of the variables accordingly The default value for both variables is virtual console For more information about setting these variables for available connection methods refer to the Sun Blade T6340 Server Module Installation and Administration Guide Using the Remote Console 43 Vv Configuring the Host in Solaris OS 1 Become root then type eeprom output device rscreen eeprom input device rkeyboard 2 Activate the change by using the reboot command The console no longer provides output 3 Exit the console to return to the ILOM SP using the ILOM escape sequence H The default ILOM escape sequence is hash period 4 Start the ILOM Remote Video Console from the browser interface See Configuring ILOM for Remote Management on page 49 for more information 5 When you want to stop using Remote Console change the values of the variables accordingly The default value for both variables is virtual console For more information about setting these variables for available connection methods refer to the Sun Blade T6340 Server Module Installation and Administration Guide Resetting the Variables to the Defaults Using ILOM If you are unable to access a Solaris OS or OpenBoot ok prompt you can reset t
53. interacts with the host server Specify the Level of Diagnostics CLI on page 12 Change the Diagnostics Mode CLI on page 13 Specify Diagnostic Trigger Conditions CLI on page 13 Choose the Amount of Verbosity in Diagnostic Output CLI on page 14 Manage Diagnostic Settings CLI on page 15 V Specify the Level of Diagnostics CLI Use the HOST diag level property to control the level of diagnostic testing to be executed when diagnostics are enabled At the gt prompt type gt set HOST diag level value where value can be m min Run the minimum level of diagnostics to verify the system 12 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 m max Run the maximum set of diagnostics to fully verify system health The default value is max Y Change the Diagnostics Mode CLI Use the HOST diag mode property to control whether diagnostics are enabled and to specify which diagnostic mode is enabled At the gt prompt type gt show HOST diag mode value where value can be m off Do not run any diagnostics m normal Run diagnostics m service Run service technician diagnostics equivalent to using the preset values of HOST diag trigger all resets HOSTS diag verbosity and HOST diag level max Setting HOST diag mode service has the same effect as issuing the set SYS keyswitch_state diag command
54. ions m ILOM Overview on page 1 m Chassis Monitoring Module Features on page 2 m Updating the System Firmware on page 2 m Resetting the Password to the Factory Default on page 2 ILOM Overview Integrated Lights Out Manager ILOM is system management firmware that is preinstalled on some SPARC servers ILOM enables you to actively manage and monitor components installed in your server ILOM provides a browser based interface and a command line interface the Chassis Monitoring Module CMM of the Sun Blade 6000 Modular Chassis and Sun Blade T6340 Server Module as well as SNMP and IPMI interfaces For general information about ILOM see the Oracle Integrated Lights Out Manager ILOM 3 0 Concepts Guide Note For information about upgrading installing and configuring ILOM on your service processor see the firmware installation instructions in the Sun Blade T6340 Server Module Installation and Administration Guide and the Sun Blade T6340 Server Module Product Notes Chassis Monitoring Module Features The ILOM chassis monitoring module CMM manages the Sun Blade 6000 Modular System chassis CMM provides management of chassis components and a method of accessing the service processors in individual server modules The CMM also provides automatic control of the chassis fan speed For information about using the CMM ILOM with your chassis refer to the ILOM supplement for your chassis Updating the System F
55. irmware If an updated version of the system firmware becomes available you can obtain it from the SunSolveS web site in the form of a patch Note You cannot use Sun Update Connection Manager to obtain system firmware Resetting the Password to the Factory Default The procedure for resetting the ILOM root password to the factory default changeme requires installation of a jumper on the service processor The procedure is documented in the Sun Blade T6340 Server Module Service Manual For information about setting other service processor settings back to the factory defaults refer to Resetting the Variables to the Defaults Using ILOM on page 44 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Managing the Host This chapter contains information on ILOM features on the Sun Blade T6340 Server Module that augment the array of properties that are common to ILOM on other platforms In particular this chapter describes the properties in the HOST namespace This chapter consists of Description Links Resetting the Host Managing Host Boot Mode Viewing and Configuring Host Control Information Managing System User Interactions Resetting the Host on page 4 Boot Mode on page 4 Manage the Host Boot Mode LDoms Configuration CLI on page 5 Change the Host Boot Mode Behavior at Reset CLI on page 5 Manage the Host Boot Mode Script CLI
56. l Log Commands on page 63 ALOM CMT Shell Status and Control Commands on page 64 ALOM CMT Shell FRU Commands on page 67 ALOM CMT Shell Automatic System Recovery ASR Commands on page 67 ALOM CMT Shell Miscellaneous Commands on page 68 ALOM CMT Compatibility Shell 59 ALOM CMT Shell Configuration Commands TABLE ALOM CMT Shell Configuration Commands ALOM CMT Command password restartssh setdate mmdd HHMM mmddHHMM cclyy SS setdefaults a setkeyswitch normal stby diag locked setsc param value setupsc showplatform v Summary Changes the login password of the current user Restarts the SSH server so that new host keys generated by the ssh keygen command are reloaded Sets ALOM CMT date and time Resets all ALOM CMT configuration parameters to their default values The a option resets the user information to the default one admin account only Sets the status of the virtual keyswitch Setting the virtual keyswitch to standby stby powers off the server Before powering off the host server ALOM CMT asks for a confirmation Sets the specified ALOM CMT parameter to the assigned value Runs the interactive configuration script This script configures the ALOM CMT configuration variables Displays information about the host system s hardware configuration and whether the hardware is providing service The v option displays v
57. min Diagnostics print a limited amount of output on the system console m max Diagnostics print full output on the system console including the name and results of each test being run m normal Diagnostics print a moderate amount of output on the system console m debug Diagnostics print extensive debugging output on the system console including devices being tested and debug output of each test The default value is normal For example gt show HOST status HOST Properties 14 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 status Solaris running Commands cd set show V Manage Diagnostic Settings CLI Use the show HOST status command to display information about the host server s platform ID and status At the gt prompt type gt show HOST status For example gt show HOST status HOST Properties status Solaris running Commands cd set show Managing System User Interactions The system user properties enable you to customize the way ILOM identifies and interacts with the host server m Enable the System to Send a Break Signal or Force a Core Dump CLI on page 16 a Display Host Status Information CLI on page 16 Managing the Host 15 Vv Enable the System to Send a Break Signal or Force a Core Dump CLI Use the set HOST send_break_action command to bring the server to a menu from which yo
58. mware from an earlier version and selected the option to preserve the settings of your earlier version of ILOM you can continue to use your prior settings including the username admin and password without recreating the admin username as described in this task If you use the original password for the username root supplied with ILOM firmware ILOM warns you that the password is still set to the factory default 1 Log onto the service processor with a username that has been assigned the user management u role When powered on the SP boots to the ILOM login prompt XXXXXXXXXXXXXXXXXX login username Password Waiting for daemons to initialize Daemons ready Integrated Lights Out Manager Version 3 0 x x Copyright 2008 Sun Microsystems Inc All rights reserved Use is subject to license terms Warning password is set to factory default 2 Create a user named admin and set the admin account roles to aucro and the CLI mode to alom gt create SP users admin Creating user Enter new password Enter new password again ALOM CMT Compatibility Shell 55 Created SP users admin gt set SP users admin role aucro Set role to aucro gt set SP users admin cli_mode alom Set cli_mode to alom Note The asterisks in the example will not appear when you enter your password You can combine the create and set commands on a single line gt
59. ntenus produits ou services tiers ou a leur utilisation eo n 4 Adobe PostScript Contents Using This Documentation xi Understanding ILOM for the Sun Blade T6340 Server Module 1 ILOM Overview 1 Chassis Monitoring Module Features 2 Updating the System Firmware 2 Resetting the Password to the Factory Default 2 Managing the Host 3 Resetting the Host 4 Managing Host Boot Mode 4 Boot Mode 4 v Manage the Host Boot Mode LDoms Configuration CLI 5 v Change the Host Boot Mode Behavior at Reset CLI 5 v Manage the Host Boot Mode Script CLI 6 v Display Host s Boot Mode Expiration Date CLI 7 Y View or Configure Boot Mode Settings Web Interface 7 Viewing and Configuring Host Control Information 8 v Display the Host s MAC Address CLI 8 v Display the Host s OpenBoot Version CLI 9 v Display the Host s POST Version CLI 9 v Specify Host Behavior When an Error Is Discovered During Diagnostics CLI 9 v Specify Host Behavior When the Host Stops Running CLI 10 v View and Configure Host Control Information Web Interface 10 Managing Host Diagnostics and POST 12 v Specify the Level of Diagnostics CLI 12 v Change the Diagnostics Mode CLI 13 v Specify Diagnostic Trigger Conditions CLI 13 v Choose the Amount of Verbosity in Diagnostic Output CLI 14 v Manage Diagnostic Settings CLI 15 Managing System User Interactions 15 v Enable the System to Send a Break Signal or Force a Core Dump CLI 16
60. o boot variable to disable lasts for one reset The y option enables you to skip the confirmation question The f option forces a hardware reset The c option starts the console load source tftp ipaddr pathname reset SYS start SP console script force set HOST domain control auto boot disable reset script force HOST domain control start SP console ALOM CMT Compatibility Shell 65 TABLE ALOM CMT Command Summary ALOM CMT Shell Status and Control Commands Continued Comparable ILOM Command powercycle y f poweroff y poweron setlocator on off showfaults v clearfault UUID showlocator removeblade y unremoveblade poweroff followed by poweron The f option forces an immediate poweroff otherwise the command attempts a graceful shutdown Removes the main power from the host server The y option enables you to skip the confirmation question ALOM CMT attempts to shut the server down gracefully The option forces an immediate shutdown Applies the main power to the host server or FRU Turns the Locator LED on the server on or off Displays current valid system faults Manually repairs system faults Displays the current state of the Locator LED as either on or off Pauses the service processor tasks and illuminates the blue OK to Remove LED indicating that it is safe to remove the blade The y option en
61. og in to the ILOM CLI using an account other than the admin account such as root The admin account cannot be used for the ILOM CLI as long as its CLI mode is set to the value alom In the ALOM CMT compatibility shell with few exceptions you can use commands that resemble the commands of ALOM CMT Remember that the ALOM CMT compatibility shell is an ILOM interface Refer to the Sun Blade T6340 Server Module Service Manual for information about service related ALOM CMT compatibility shell commands Comparing ILOM and ALOM CMT Commands The following tables provide a command by command comparison between the command sets of ALOM CMT and the default ILOM CLI command set Only the supported ALOM CMT command options are listed in the tables below Where there are ALOM CMT command line arguments that have no corresponding ILOM properties those ALOM CMT arguments have been omitted The command set of the ALOM compatibility shell provides a close approximation of the equivalent commands and arguments where supported in ALOM CMT Note By default information displayed by ALOM CMT commands is in a terse format Use the v flag with these commands to obtain more verbose output The ILOM show commands always provide verbose output so a terse output format is not available a ALOM CMT Shell Configuration Commands on page 60 58 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 ALOM CMT Shel
62. ok prompt or the Solaris boot output TABLE OpenBoot Remote Console Options Environment Variable Allowable Values Conditions input device output device virtual console Remote Serial Console or ILOM ssh Shell rkeyboard Remote Video Console or local USB attached keyboard virtual console Remote Serial Console or ILOM ssh Shell rscreen Remote Video Console or local VGA attached monitor The Remote Console by default provides boot information culminating in a login prompt in the Remote Serial Console and in a graphical login window in the Remote Video Console What you see depends on what value has been set for output device The output sources that have to choose from are shown below TABLE Remote Console Data Sources Data Source Remote Console Access Power on self test POST OpenBoot PROM Solaris POST is always and only accessible through the Remote Serial Console Direct OpenBoot PROM output to either the Remote Serial Console or the Remote Video Console The default is Remote Serial Console Direct Solaris output to either the Remote Serial Console or to the Remote Video Console The Solaris graphical login window is always sent to the Remote Video Console output no matter where you direct the boot progress output to be sent Using the Remote Console 41 Note If you change the value of the OpenBoot output device to something other than the default value of virtual console you can
63. on Management Snapshot Configuration Management Manage the SP configuration Option AN removes all of the SP configuration data Option Factory removes all configuration data as well as all log files Reset Defaults None zj m Reset Defaults 1 Log in to the ILOM web interface as Administrator root to open the browser interface 2 Select Maintenance gt Configuration Management 3 Select a Reset Defaults value m None Make no changes m All including users Reset clear all configurations and users 4 Click Reset Defaults V Display Console History CLI This section describes displaying the host server console output buffer The console buffer can contain up to 1 Mbyte of information If ILOM senses a host server reset it writes boot information and initialization data into the console buffer until ILOM is notified by the server that the Solaris OS is up and running If ILOM senses a host server reset it writes boot information and initialization data into the console buffer until ILOM is notified by the server that the Solaris OS is up and running Note You must have Administrator level user permission to use this command Managing the Service Processor 21 At the gt prompt type gt set SP console history property option gt show SP console history where property can be m line_count This option accepts a value within the range of 1 to 2048 lines Spe
64. oot mode settings Select an option for state either Normal or Reset NVRAM Enter the boot script and LDOM configuration State Normal xj Expiration Date none Script M LDOM Contig Save You can use the ILOM web interface to view or configure the four aspects of boot mode control m State m Expiration Date m Script LDom Configuration 1 Log in to the ILOM web interface as Administrator root to open the web interface 2 Select Remote Control gt Boot Mode Settings 3 Select the Boot Mode State if desired Managing the Host 7 4 View the Expiration Date ol Specify a boot script if desired 6 Specify an LDoms configuration file if desired 7 Click Save Viewing and Configuring Host Control Information Use the host information properties to view system configuration and firmware version information m Display the Host s MAC Address CLI on page 8 m Display the Host s OpenBoot Version CLI on page 9 m Display the Host s POST Version CLI on page 9 m Specify Host Behavior When the Host Stops Running CLI on page 10 m Specify Host Behavior When an Error Is Discovered During Diagnostics CLI on page 9 a View and Configure Host Control Information Web Interface on page 10 V Display the Host s MAC Address CLI The HOST macaddress property is automatically configured by the system software so you cannot set or
65. ootmode property value where property is state config or script 64 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE ALOM CMT Shell Status and Control Commands Continued ALOM CMT Command Summary Comparable ILOM Command flashupdate s IPaddr f pathname v y c reset E d c n Downloads and updates system firmware both host firmware and ALOM CMT firmware For ILOM ipaddr must be a TFTP server If you use DHCP you can replace ipaddr with the name of the TFTP host The y option enables you to skip the confirmation question The c option enables you to update system firmware on your server without preserving configuration information After configuration information has been deleted by having used the c option or the set SP reset_to_defaults factory command you must use the c option when replacing system firmware that includes ILOM 3 0 with firmware that includes ILOM 2 0 If you omit the c option the flashupdate command attempts to restore preserved configuration information halting the firmware downgrade because that configuration information is absent Generates a hardware reset on the host server The y option enables you to skip the confirmation question The f option forces a hardware reset The c option starts the console The d option gracefully resets the control domain The n option sets the aut
66. or Reference 51 52 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 ALOM CMT Compatibility Shell ILOM supports some of the features of the ALOM CMT command line interface by means of a compatibility shell There are significant differences between ILOM and ALOM CMT This chapter describes those differences This chapter includes the following topics m Limits to Backward Compatibility on page 53 m Create an ALOM CMT Compatibility Shell on page 55 a Comparing ILOM and ALOM CMT Commands on page 58 Limits to Backward Compatibility The backward compatibility shell supports some but not all features of ALOM CMT Some of the more significant differences between ILOM and ALOM CMT are described in this section or in the product notes for your server Adding a Commit Step to Procedures That Configure ILOM Network Configuration Properties In the original ALOM CMT environment when changing the values of some ALOM CMT variables such as network and serial port configuration variables it was necessary to reset the service processor called the system controller in ALOM CMT before the changes took effect By comparison in ILOM and the ALOM CMT compatibility shell you must commit the changed values rather than resetting the service processor Caution In ILOM if you change the value of the property and reset the SP without committing the change the new property setting will n
67. or Version Hypervisor 1 7 6 2009 12 01 14 30 OBP Version OBP 4 30 6 2009 12 01 12 41 POST Version POST 4 30 6 2009 12 01 1318 Sy sFW Version Sun System Firmware 7 2 7 8 200912 25 03 05 Host Status Solaris running Auto Run On Error Faise gt Auto Restart Policy Reset zi Boot Timeout CS Boot Restart Policy None Max Boot Fails Allowed 3 Boot Fail Recovery Poweron gt _ Save ILOM enables you to view or configure several host control features There are six aspects to host control m MAC address OpenBoot version m POST version m HOST status m Auto Run On Error Auto Restart Policy 1 Log in to the ILOM web interface as Administrator root to open the web interface 2 Select Remote Control gt Host Control 3 View the MAC address 4 View the Hypervisor version 5 View the OpenBoot version Managing the Host 11 10 11 12 13 14 15 View the POST version View the System Firmware version View the Host status Select a value for Auto Run On Error if desired Select a value for Auto Restart Policy if desired Select a value for Boot Timeout if desired Select a value for Boot Restart Policy if desired Select a value for Maximum Boot Failures Allowed if desired Select a value for Boot Failure Recovery if desired Click on Save Managing Host Diagnostics and POST The system user properties enable you to customize the way ILOM identifies and
68. ot be retained 53 V Commit a Change to a Network Configuration Property 1 Change the value of the target network configuration property 2 Commit the change For example set a static IP address using the ALOM compatibility CLI sc gt setsc netsc_ipaddr xxx xxx xxx xxx sc gt setsc netsc_commit true To set the same property using the ILOM CLI gt set SP network pendingipaddress xxx xxx xxx XXx Set pendingipaddress to XXX XXX XXX XXX gt set SP network commitpending true Set commitpending to true V Commit a Change to a Serial Port Configuration Property 1 Change the value of the target serial port configuration property 2 Commit the change Use either the ALOM CMT command setsc ser_commit true or the ILOM command set SP serial external commitpending true See Comparing ILOM and ALOM CMT Commands on page 58 for a list of variables and corresponding properties ALOM CMT Variable Comparable ILOM Property netsc_commit SP network commitpending ser_commit SP serial external commitpending 54 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 V Create an ALOM CMT Compatibility Shell Your server is configured to operate under an ILOM shell by default You can create an ALOM compatibility shell if you prefer to use commands that resemble ALOM CMT commands to administer your server Note If you upgraded the fir
69. plication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 07 19 Commercial Computer Software License December 2007 Oracle USA Inc 500 Oracle Parkway Redwood City CA 94065 This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including applications which may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible to take all appropriate fail safe backup redundancy and other measures to ensure the safe use Oracle Corporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications Oracle and Java are registered trademarks of Oracle and or its affiliates Other names may be trademarks of their respective owners AMD Opteron the AMD logo and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc UNIX is a registered trademark licensed thro
70. pt type gt set SP customer_frudata daia Note The data string data must be enclosed in quote marks Y Change System Identification Information CLI Use the SP system_identifier property to store customer identification information Atthe gt prompt type gt set SP system identifier data Note The data string data must be enclosed in quote marks 18 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 V Change Customer Identification Information Web Interface Fault Identification Banner Session Overview Components Management Information Messages Timeout Versions Identification Information Configure identification information The setting for Physical Presence Check indicates whether a button press will be required for security related actions such as password recovery Customer FRU Data test25 SP Hostname Netra SOLP SP System kientifier SP System Contact SP System Location i SP System Description none Physical Presence Check PF Enabled Save ILOM provides features that enable you to store information on FRUs and the SP 1 Log in to the ILOM web interface as Administrator root to open the web interface 2 Select System Information gt Identification Information 3 Edit the Customer FRU data field if desired 4 Edit the SP Hostname if desired 5 Edit the SP System
71. r state on boot enabling this policy disables Auto power on host policy Disabled C Setto delay host power on Disabled Setto enable backing up of user account info to SCC card Enabled Managing the Service Processor 25 1 Log in to the ILOM web interface as Administrator root to open the web interface 2 Select Configuration gt Policy 3 Click the Policy radio button of the policy you want to change 4 Select an Action value to apply the Action enable or disable you have chosen Managing Power Usage and Monitoring Power Consumption This section describes how to use power management interfaces to manage power usage and to monitor power consumption m Power Management Interfaces on page 26 m Power Management Terminology on page 27 m View Power Management Properties CLI on page 28 a View the Total Power Consumed by the System CLI on page 28 a Viewing Total Available Power CLI on page 29 m Monitoring Permitted Power Consumption CLI on page 30 m Using the Power Consumption Control Interfaces on page 30 m Setting the Power Policy CLI on page 30 m Viewing the Power Policy CLI on page 31 a Viewing Power Management Properties Web Interface on page 31 Power Management Interfaces Power management interfaces enable you to configure and display the power management policy of the system You use power management policies to manage power
72. showcomponent Displays system components and component their test status clearasrdb Removes all entries from the list of disabled components set SYS component component_state disabled show SYS component component_state No equivalent in ILOM ALOM CMT Compatibility Shell 67 ALOM CMT Shell Miscellaneous Commands TABLE ALOM CMT Shell Miscellaneous Commands ALOM CMT Command help command resetsc y userclimode username shelltype logout setsc sys_ioreconfigure value Summary Displays a list of all ALOM CMT commands with their syntax and a brief description of how each command works Specifying a command name as an option enables you to view the help for that command Reboots ALOM CMT The y option enables you to skip the confirmation question Sets the type of shell to shelltype where shelltype is default or alom Logs out from an ALOM CMT shell session Sets the ioreconfiguration parameter to value where value is true false or next boot Comparable ILOM Command help reset script SP set SP users username cli_mode shelltype exit set HOST ioreconfigure value 68 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 ALOM CMT Variables This chapter contains the following topic m ALOM CMT Variable Comparison on page 69 ALOM CMT Variable Comparison TABLE ALOM CMT Variables and Comparable ILOM Properties
73. t Boot Mode Behavior at Reset CLI on page 5 a Display Host s Boot Mode Expiration Date CLI on page 7 m View or Configure Boot Mode Settings Web Interface on page 7 Boot Mode You can use the boot mode bootmode properties to specify how ILOM handles booting This ability is useful to override particular OpenBoot or LDoms settings that might be incorrect to set up OpenBoot variables using a script or similar tasks For example if the OpenBoot settings have become corrupt you can set the bootmode state property to reset_nvram then reset the server to its factory default OpenBoot settings Service personnel might instruct you to use the bootmode script property for problem resolution The full extent of script capabilities are not documented and exist primarily for debugging Because bootmode is intended to be used to correct problems with the OpenBoot or LDoms settings the bootmode takes effect for a single boot only Additionally to prevent an administrator from setting a bootmode state property and forgetting about it a bootmode state property expires if the host is not reset within 10 minutes of the bootmode state property being set Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 bootmode properties can be configured using either the ILOM command line interface CLI or the web interface Manage the Host Boot Mode LDoms Configuration CLI Atthe gt prompt type
74. ted and siesta policies are not supported currently For a description of each of these values see the definition of Power Policy in the table in Power Management Terminology on page 27 V Setting the Power Policy CLI Type the set command to set the power policy For example set the power policy to performance gt set SP powermgmt policy performance 30 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 V Viewing the Power Policy CLI Type the show command to display the power policy For example gt show SP powermgmt policy V Viewing Power Management Properties Web Interface System System Power u JR ET Deropomoni CORNOWBIOR Melon Conros Mentone Consumption Allocation Settings History Power Consumption View actual system input power consumption power consumption limit and configure notification thresholds from this page An ILOM event is generated when the actual power consumption exceeds either threshold Actual Power 198 watts The input power the system is currently consuming Peak Permitted 420 watts Maximum power the system will ever consume Notification Threshoki 1 Enabled watts The default is Disabled 0 Notification Threshoki2 Enabled watts The default is Disabled 0 a Save SL 1 Log in to the ILOM web interface as Administrator root to open the web interface 2 Select System Monitoring
75. ten TABLE ILOM Properties Stored on the SCC Properties Targets SP users username SP network HOST diag HOST SP policy SP services ssh state SP clients smtp SP alertmgmt rules 1 15 if the alert is an email alert SP system_identifier SYS keyswitch name password role cli_mode ipaddress ipdiscovery ipgateway ipnetmask state trigger level verbosity mode autorunonerror autorestart HOST_LAST_POWER_STATE HOST_POWER_ON_DELAY BACKUP_USER_DATA N A address port state destination level type N A N A 82 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 TABLE ALOM CMT Conditional Variables Variable sc_clipasswecho sc_cliprompt sc_clitimeout sc_clieventlevel sc_eschapechars SCC Backup and Restore 83 84 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Index Symbols HOST autorestart property 10 HOST autorunonerror property 9 HOST macaddress property 8 HOST send_break_action property 12 16 HOST status property 15 16 HOST bootmode config property 5 HOST bootmode expires property 7 HOST bootmode script property 6 HOST bootmode state property 5 SP system_identifier property 18 SP console escapechars property 22 SP policy BACKUP_USER_DATA property 23 SP policy HOST_AUTO_POWER_ON property 24 SP policy HOST_LAST_POWER_STATE
76. the server in nonvolatile storage If the HOST_LAST_POWER_STATE policy is enabled ILOM can restore the host to the previous power state This policy is useful in the event of a power failure or if you physically move the server to a different location For example if the host server is running when power is lost and the SP policy HOST_LAST_POWER_STATE property is set to disabled the host server remains off when power is restored If the SP policy HOST_LAST_POWER_STATE property is set to enabled the host server restarts when the power is restored At the gt prompt type gt set SP policy HOST LAST POWER_STATE enabled where value can be a enabled When power is restored returns the server to the state it was in before the power was removed m disabled Keeps the server off when power is applied the default The default value is disabled If you enable HOST_LAST_POWER_STATE you should also configure SP policy HOST_POWER_ON_DELAY For further information see Disable or Re Enable Power On Delay CLI on page 25 Specify Host Power State at Restart CLI Use SP policy HOST_AUTO_POWER_ON to power on the host automatically when the service processor has been booted If this policy is set to enabled the service processor sets HOST_LAST_POWER_STATE to disabled At the gt prompt type gt set SP policy HOST AUTO POWER ON Ualue where value can be a enabled When power is
77. tive System Faults on page 35 V Displaying Active System Faults At the ILOM CLI prompt gt type the show faulty command The show faulty command is a shortcut for the following ILOM command string gt show o table level all SP faultmgmt The shortcut produces the same output as the longer command string displaying all active faults in the system in a concise tabular format For example gt show faulty Target Property Value Sesto a SP faultmgmt 0 fru SYS MB SP faultmgmt 0 timestamp Jan 16 12 53 00 SP faultmgmt 0 sunw msg id NXGE 8000 0U faults 0 SP faultmgmt 0 uuid e19f07a5 580e 4ea0 ed6af663aa61 Managing the Service Processor 35 faults 0 SP faultmgmt 0 timestamp Jan 16 12 53 00 faults 0 36 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Managing Devices This chapter contains information on ILOM properties on the Sun Blade T6340 Server Module that augment the array of properties that are common to ILOM on other platforms In particular this chapter covers properties in the SYS namespace m Managing Virtual Keyswitch Settings on page 37 Managing Virtual Keyswitch Settings m Specify Host Behavior CLI on page 37 m Control the Virtual Keyswitch Web Interface on page 38 Vv Specify Host Behavior CLI Use the SYS keyswitch_state property to control the position of the virtual keyswitch
78. u can choose to go to the OpenBoot PROM prompt ok If you have configured the kmdb debugger then specifying the send_break_action break command brings the server into debug mode Specify send_break_action dumpcore to force a core dump At the gt prompt type gt set send_break_ action value where value can be m break Sends a break to the host m dumpcore Forces a panic core dump of the managed system OS not supported by all OS versions Vv Display Host Status Information CLI Use the show HOST status command to display information about the host server s platform ID and status At the gt prompt type gt show HOST status For example gt show HOST status HOST Properties status Solaris running Commands cd set show 16 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Managing the Service Processor This chapter contains information on ILOM properties on the Sun Blade T6340 Server Module that augment the array of properties that are common to ILOM on other platforms In particular this chapter covers properties in the SP namespace This chapter consists of Description Links Storing Customer Information Changing Service Processor Settings to Factory Defaults Displaying Console History Modifying Console Escape Characters Changing Configuration Policy Settings Managing Network Access
79. ugh X Open Company Ltd This software or hardware and documentation may provide access to or information on content products and services from third parties Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third party content products and services Oracle Corporation and its affiliates will not be responsible for any loss costs or damages incurred due to your access to or use of third party content products or services Copyright 2009 2010 Oracle et ou ses affili s Tous droits r serv s Ce logiciel et la documentation qui l accompagne sont prot g s par les lois sur la propri t intellectuelle Ils sont conc d s sous licence et soumis a des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer ex cuter publier ou afficher le logiciel m me T mieleni sous quelque forme et par quelque proc d que ce soit Par ailleurs il est interdit de proc der toute ing nierie inverse du logiciel de le d sassembler ou de le d compiler except a des fins d interop rabilit avec des logiciels tiers ou tel que prescrit par la loi Les informations fournies dans ce document sont susceptibles de modification sans pr avis Par ailleurs Oracle Corporation ne garantit pas qu elles soient
80. usage based on user requirements Power policies enable you to optimize power usage to match system requirements Note An SNMP MIB PM ILOM MIB is available to support power management software 26 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Power Management Terminology Table 3 1 defines the terminology used in power management TABLE Power Management Terms Term Definition Actual power The input power measured in Watts This is the actual power consumed by all the power supplies in the system Permitted power The maximum power that the server will permit to be used at any time Available power The input power capacity in Watts For the server modules available power is the amount of power available to the server module from the chassis Power policy The setting that governs system power usage at any point in time Four power policies are supported Performance The system is allowed to use all the power that is available e Elastic The system power usage is adapted to the current utilization level For example power up or down just enough system components to keep relative utilization at 70 at all times even if the workload fluctuates Regulated N A e Siesta N A Managing the Service Processor 27 V View Power Management Properties CLI At the gt prompt type the following command gt show SP powermgmt For example gt show S
81. v Display Host Status Information CLI 16 Managing the Service Processor 17 Storing Customer Information 18 v Change Customer FRU Data CLI 18 v Change System Identification Information CLI 18 v Change Customer Identification Information Web Interface 19 Changing Service Processor Settings to Factory Defaults 20 v Reset Service Processor Settings to Factory Default Values CLI 20 v Reset Service Processor Settings to Factory Default Values Web Interface 21 v Display Console History CLI 21 v Change Console Escape Characters CLI 22 Changing Configuration Policy Settings 23 v Specify Backup of the User Database CLI 23 Restore Host Power State at Restart CLI 24 v Specify Host Power State at Restart CLI 24 v Disable or Re Enable Power On Delay CLI 25 v Manage Configuration Policy Settings Web Interface 25 vi Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 Managing Power Usage and Monitoring Power Consumption 26 Power Management Interfaces 26 Power Management Terminology 27 v View Power Management Properties CLI 28 v View the Total Power Consumed by the System CLI 28 v Viewing Total Available Power CLI 29 v Monitoring Permitted Power Consumption CLI 30 Using the Power Consumption Control Interfaces 30 v Setting the Power Policy CLI 30 v Viewing the Power Policy CLI 31 v Viewing Power Management Properties Web Interface 31 Managing Network Access 32 v Disable or
82. ynchronized Generates Secure Shell SSH host keys and displays the host key fingerprint on the SC Use the ILOM show FRU command to display static FRU information For dynamic FRU information use the ALOM CMT showfru command show level all o table SP sessions No equivalent in ILOM for g option show HOST show SYS keyswitch_state show target property show SP clock datetime show SP services ssh keys rsa dsa set SP services ssh generate_new_key_action true set SP services ssh generate_new_key_type rsa dsa ALOM CMT Compatibility Shell 61 TABLE ALOM CMT Command Summary ALOM CMT Shell Configuration Commands Continued Comparable ILOM Command usershow username useradd username userdel y username userpassword username userperm username c ul a r o s Displays a list of all user accounts and permission levels and whether passwords are assigned Adds a user account to ALOM CMT Deletes a user account from ALOM CMT The y option enables you to skip the confirmation question Sets or changes a user password Sets the permission level for a user account show SP users create SP users username delete script SP users username set SP users username password set SP users username role permissions alulclrlols 62 Oracle ILOM 3 0 Supplement for the Sun Blade T6340 Server Module Appril 2010 ALOM CMT Shell Lo
83. ystem Controller Usage Event Messages Continued Severit y Message Description Major Host has been powered on ALOM compatibility shell sends this message when the SC requests a host power on either because of sc_powerstatememory or when a user types the poweron command Critica Host has been reset ALOM compatibility shell sends one of these 1 Host has been powered off messages when the SC requests a host reset Critica Host has been powered on including when a user types the reset command 1 Critica 1 Critica Host System has Reset ALOM compatibility shell sends this message 1 when the SC detects that the host has reset This message is followed immediately by the Host has been powered off event message because reset is implemented as a powercycle on these systems Minor root Set object ALOM compatibility shell sends this message clock datetime value when a user types the setdate command to datetime success modify the SC date or time Major Upgrade succeeded ALOM compatibility shell sends this message after the SC firmware has been reloaded after operation of the flashupdate command Minor root Set object ALOM compatibility shell sends this message HOST bootmode state after a user changes the bootmode to normal value bootmode value using the bootmode normal command success Minor root Set object ALOM compatibility shell sends this message HOST bootmode state after a user changes the boot
Download Pdf Manuals
Related Search
Related Contents
Copyright © All rights reserved.
Failed to retrieve file