Home

Oracle Integrated Lights Out Manager 2.0 Supplement for the Sun

image

Contents

1. 1 Log into the ILOM web interface as Administrator root to open the web interface 2 Select Remote Control gt Host Control 3 View the MAC address 4 View the OpenBoot version 5 View the POST version 6 Select a value for Auto Run On Error 7 Select a value for Auto Restart Policy 8 Click on Save 10 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Managing Host Diagnostics Use the diagnostic control properties to specify how ILOM behaves when it encounters an error on the host server ILOM uses the following diagnostic system interface property To Specify the Level of Diagnostics Using the CLI on page 11 To Change the Diagnostics Mode Using the CLI on page 11 To Specify Diagnostic Trigger Conditions Using the CLI on page 12 To Choose the Amount of Verbosity in Diagnostic Output Using the CLI on page 13 To Manage Diagnostics Settings Using the Web Interface on page 13 V To Specify the Level of Diagnostics Using the CLI Use the HOST diag level property to specify the level of diagnostic testing to be executed when diagnostics are enabled Type gt set HOST diag level value where value is one of the following m min Run the minimum level of diagnostics to verify the system the default value m max Run the maximum set of diagnostics to fully verify system health V To Change the
2. TABLE B 2 ALOM CMT Command Summary ALOM CMT Shell Commands by Function Continued Comparable ILOM Command reset d f n powercycle y f powercycle y powercycle f poweroff poweroff y poweroff f poweron setlocator on off v showfaults clearfault UUID When resetting the control domain this option does not automatically boot and stays at the OpenBoot ok prompt This option overrides all reboot variables and stops the control domain at the OpenBoot ok prompt after host reset The auto boot option remains unchanged thus subsequent reset commands automatically reboot host if the auto boot option is set to true poweroff followed by poweron The option forces an immediate poweroff otherwise the command attempts a graceful shutdown Removes the main power from the host server The y option enables you to skip the confirmation question ALOM CMT attempts to shut the server down gracefully The option forces an immediate shutdown Applies the main power to the host server or FRU Turns the Locator LED on the server on or off Displays current valid system faults Manually repairs system faults set HOST domain control auto boot disable reset f HOST domain control stop SYS start SYS stop script SYS script SYS force SYS force SYS start stop start stop SYS stop script SYS stop force SYS start SYS
3. 5 HOST diag level 11 HOST diag mode 11 HOST diag trigger 12 HOST diag verbosity 13 SP customer_frudata 18 SP reset_to_defaults 19 SP system_identifier 18 SP console escapechars 21 SP policy BACKUP_USER_DATA 22 SP policy HOST_POWER_ON_DELAY 23 SP services ssh generate_new_key_action 28 SP services ssh generate_new_key_type 28 SP services ssh restart_sshd_action 28 29 SP services ssh state 29 SYS keyswitch_state 733 M memory of power state 22 P platform showing 15 power state 22 property backup data 21 memory of power state 22 system user 15 R remote control settings changing with the CLI 3 changing with the web interface 6 S server platform information 15 setalarm ALOM command 45 56 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010
4. HOST send_break_action dumpcore Controls the host server set HOST bootmode property value OpenBoot PROM where property is state config or script firmware method of booting 48 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 TABLE B 2 ALOM CMT Command Summary ALOM CMT Shell Commands by Function Continued Comparable ILOM Command flashupdate s IPaddr pathname v reset reset reset f reset d reset d f reset d n Downloads and updates system firmware both host firmware and ALOM CMT firmware For ILOM ipaddr must be a TFTP server If DHCP is used ipaddr can be replaced by the name of the TFTP host Attempts to gracefully reset the system If that fails this option forcefully resets the system Forcefully resets the system Attempts to gracefully reset the control domain If that fails this option forcefully resets the control domain Forcefully resets the control domain When resetting the control domain this option may automatically boot this is default behavior when the auto boot option is not specified load source t ftp ipaddr pathname reset reset reset reset reset SYS script SYS f SYS HOST domain control f HOST domain control set HOST domain control auto boot disable reset HOST domain control Appendix B ALOM CMT Compatibility Shell 49
5. of the server after an unexpected power outage When external power is restored the ILOM service processor starts to run automatically Normally the host power is not turned on until you use ILOM to turn it on ILOM records the current power state of the server in non volatile storage If the HOST_LAST_POWER_STATE policy is enabled ILOM can restore the host to the previous power state This policy is useful in the event of a power failure or if you physically move the server to a different location For example if the host server is running when power is lost and the SP policy HOST_LAST_POWER_STATE property is set to disabled the host server remains off when power is restored If the SP policy HOST_LAST_POWER_STATE property is set to enabled the host server restarts when the power is restored At the gt prompt type the following command gt set SP policy HOST LAST POWER_STATE enabled where the value for this property can be one of the following m enabled When power is restored returns the server to the state it was in before the power was removed m disabled Keeps the server off when power is applied If you enable this property you must configure SP policy HOST_POWER_ON_DELAY as well For further information see To Disable or Re Enable Power On Delay Using the CLI on page 23 22 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Vv To Di
6. on page 44 a ALOM CMT Variable Comparison on page 52 Backward Compatibility Limits The backward compatibility shell supports some but not all features of ALOM CMT Some of the more significant differences between ILOM and ALOM CMT are described here or in the product notes for your server Adding a Commit Step to Procedures That Configure ILOM Network Configuration Properties When changing the values of some ALOM CMT variables such as network and serial port configuration variables it was necessary to reset the system controller before the changes took effect By comparison in ILOM it is not necessary to reset the service processor after changing the values of comparable properties In ILOM if you change the value of the property and then reset the SP you will lose the new property setting 41 Instead change the network configuration property then commit it using setsc netsc_commit in the the ALOM compatibility CLI or set SP network commitpending using the ILOM CLI To change the serial port configuration property then commit it using setsc ser_commit in the the ALOM compatibility CLI or set SP serial external commitpending using the ILOM CLI For example set a static IP address using the ALOM compatiblitiy CLI sc gt setsc netsc_ipaddr xxx xxx xxx xxx sc gt setsc netsc_commit To set the same property using the ILOM CLI gt set SP network pendingipaddress xxx xxx xXX XXx Set pendingipaddress
7. ILOM web interface as Administrator root to open the web interface Select Remote Control gt Boot Mode Settings Select the Boot Mode State View the Expiration Date Specify a boot script Specify an LDom configuration file Click Save Viewing Host Information and Setting System Policy Concerning Error Conditions Use the system information properties to view system configuration and firmware version information To Display the Host s MAC Address Using the CLI on page 8 To Display the Host s OpenBoot Version Using the CLI on page 8 To Display the Host s POST Version Using the CLI on page 8 To Specify Host Behavior When the Watchdog Timer Expires Using the CLI on page 9 To Specify Host Behavior When an Error Is Discovered During Diagnostics Using the CLI on page 9 To View Host Information Using the Web Interface on page 9 Chapter 2 Managing the Host 7 V To Display the Host s MAC Address Using the CLI The HOST macaddress property is automatically configured by the system software so you cannot set it or change it The value is read and determined from the server s MAC address and then stored as a property in ILOM HOST macaddress is the MAC address for the net0 port The MAC addresses for each additional port increments from the HOST macaddress For example net1 is equal to the value of HOST macaddress plus one 1 To view the current setting fo
8. Keyswitch Diagnostics Select the level of embedded diagnostics to run on the host during start up The Trigger contains all possible states to cause diagnostics to be run The Verbosity level will define how much information will be given The Update Mode contains all the possible OPS modes specified to POST Trigger All Resets Verbosity Normal Level Max v Current Mode off Update Mode off v L Chapter 2 Managing the Host 13 ILOM provides several ways to view or configure diagnostics There are four aspects to host control Trigger m Verbosity m Level m Mode 1 Log into the ILOM web interface as Administrator root to open the web interface 2 Select Remote Control gt Diagnostics 3 Select a value for Trigger 4 Select a value for Verbosity 5 Select a value for Level 6 View the Current Mode 7 Select a value for Update Mode Managing System User Interactions The system user properties enable you to customize the way ILOM identifies and interacts with the host server m To Enable the System to Send a Break Signal or Force a Core Dump Using the CLI on page 15 a To Display Host Status Information Using the CLI on page 15 V To Enable the System to Send a Break Signal or Force a Core Dump Using the CLI Use the set HOST send_break_action command to bring the server to a menu from which you can choose to go to the OpenBoot PROM prompt ok If you have configured t
9. list of all ALOM CMT commands with their syntax and a brief description of how each command works Specifying a command name as an option enables you to view the help for that command help Appendix B ALOM CMT Compatibility Shell 51 TABLE B 2 ALOM CMT Command Summary ALOM CMT Shell Commands by Function Continued Comparable ILOM Command resetsc resetsc y userclimode logout Reboots ALOM CMT The reset SP y option enables you to skip the confirmation question Sets the type of shell to shelltype where shelltype is default or alom Logs out from an ALOM CMT shell session reset script SP set SP users username cli_mode shelltype exit ALOM CMT Variable Comparison The following table displays ALOM CMT variables and the ILOM properties to which they can be compared The comparison does not imply a one to one mapping To understand the ILOM properties it is necessary to view them in their own context ILOM TABLE B 3 ALOM CMT Variables and Comparable ILOM Properties ALOM CMT Variable Comparable ILOM Property diag_level diag_mode diag_trigger diag_verbosity if_connection if_emailalerts if_network if_snmp mgt_mailalert mgt_mailhost mgt_snmptraps mgt_traphost HOS1 HOS1 HOS1 r diag level r diag mode r diag trigger HOS1 r diag verbosity SP services ssh state SP clients smtp state SP network st
10. set SYS LOCATE value value show SP faultmgmt set SYS component clear_fault_action true 50 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 TABLE B 2 ALOM CMT Command Summary ALOM CMT Shell Commands by Function Continued Comparable ILOM Command showlocator FRU Commands setfru c data showfru g lines s d FRU removefru y FRU Displays the current state of the Locator LED as either on or off The c option enables you to store information such as inventory codes on all FRUs in a system Displays information about the FRUs in a host server Prepares a FRU for example a power supply for removal The y option enables you to skip the confirmation question show SYS LOCATE set SP customer_frudata data No equivalent in ILOM set SYS PSO prepare_to_remove_action true Automatic System Recovery ASR Commands enablecomponent asr key disablecomponent asr key showcomponent asr key clearasrdb Removes a component from the asr db blacklist Adds a component to the asr db blacklist Displays system components and their test status ASR state Removes all entries from the asr db blacklist set SYS component component_state enabled set SYS component component_state disabled show SYS component component_state No equivalent in ILOM Other Commands help command Displays a
11. 10 V To Manage the Host s Boot Mode Script Using the CLI Type gt set HOST bootmode script value where script controls the host server OpenBoot PROM firmware method of booting The script does not affect the current HOST bootmode setting string can be up to 64 bytes in length You can specify a HOST bootmode setting and set the script within the same command For example gt set HOST bootmode state reset_nvram script setenv diag switch true After the server resets and OpenBoot PROM reads the values stored in the script firmware sets the OpenBoot PROM variable diag switch to the user requested value of true Note Note If you set HOST bootmode script ILOM sets the script to empty If you set HOST bootmode config ILOM sets the config to empty Vv To Change the Host s Boot Mode Behavior at Reset Using the CLI The HOST bootmode state property controls how OpenBoot nonvolatile random access memory NVRAM variables are used Normally the current settings of these variables are retained Setting HOST bootmode state reset_nvram changes the OpenBoot NVRAM variables to their default settings at the next reset Type gt set HOST bootmode state value where value is one of the following m normal At next reset retains current NVRAM variable settings a reset_nvram At next reset returns OpenBoot variables to default settings Chapter 2 Managing the Host 5 N
12. Diagnostics Mode Using the CLI Use the HOST diag mode property to control whether diagnostics are enabled and to specify which diagnostic mode is enabled Type gt set HOST diag mode value where value is one of the following Chapter 2 Managing the Host 11 V To off Run no diagnostics normal Run diagnostics the default value service Run service technician diagnostics equivalent to using the preset values of HOST diag trigger all resets HOST diag verbosity and HOST diag level max Setting HOST diag mode service has the same effect as issuing the set SYS keyswitch_state diag command Specify Diagnostic Trigger Conditions Using the CLI Use the HOST diag trigger property to control the conditions under which POST runs if diagnostics are enabled Type Sr set HOST diag trigger value where value is one or a combination supplied within quote marks of the following user reset Run diagnostics when the system is reset error reset Run diagnostics when the system takes a fatal error that requires the system to reset itself to recover power on reset Run diagnostics when the system is powered on all resets Run all of the diagnostics specified by user reset error reset and power on reset the default value none Skip diagnostics The default value is the combination of power on reset error reset For example gt set HOST di
13. I 27 v To Display the DHCP Server s IP Address 27 Managing SSH Server Settings 28 To Change the Type of SSH Keys Using the CLI 28 To Generate a New Set of SSH Keys Using the CLI 28 v To Restart the SSH Server Using the CLI 28 v To Enable or Disable the SSH Service Using the CLI 29 v To Manage SSH Server Settings Using the Web Interface 30 Managing Devices 33 Managing Virtual Keyswitch Settings 33 v To Control the Virtual Keyswitch Using the CLI 33 v To Control the Virtual Keyswitch Using the Web Interface 34 IPMI Sensor Reference 37 ALOM CMT Compatibility Shell 41 Backward Compatibility Limits 41 Adding a Commit Step to Procedures That Configure ILOM Network Configuration Properties 41 Creating an ALOM CMT Shell 42 Contents v v To Create an ALOM CMT Compatibility Shell 43 ILOM and ALOM CMT Command Comparison 44 ALOM CMT Variable Comparison 52 Index 55 vi Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Tables TABLE A 1 TABLE A 2 TABLE B 1 TABLE B 2 TABLE B 3 Sensors on the Sun Netra T5440 Server 37 Indicators on Sun Netra T5440 Server 38 ALOM CMT commit Variables and Comparable ILOM Properties 42 ALOM CMT Shell Commands by Function 45 ALOM CMT Variables and Comparable ILOM Properties 52 vii viii Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Preface This supplement contains informati
14. J666 3E6q k PwhoF S5J 40p1 XhMauLo6uxMN6AatLgHK6bR7 zrjM1D6wZED IAFXTAYTyEa8 u0RQiKoorDggKByOq g71s u AS0EcVKFy QxKeRpiYOI 6gmKR QAAAIBzt6knhelRczyA0dtIw8AP1nHr L3cu7Z2i10Zn1rkpc7100o21UUPOSJf21MEYHESQc 4gx j ZvnP PNOCLmqud j OMWrmMi zUheZGpHsIe9q2 qhET8UoBSQ9T0VaQ qQhJr1r5jotcBDxRwHRIHf1IFEAptls0iC a865 P8VY8PPUb NQ DSA Public Key 1 Log into the ILOM web interface as Administrator root to open the web interface 2 Select Configuration gt SSH Server Settings 30 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 3 Select an action from the SSH Server pulldown menu m Enable the SSH server a Disable the SSH server m Restart the SSH server 4 Click Generate RSA Key or Click Generate DSA Key to generate a new key type and a new key If you have generated a new key you must restart the SSH server for the new key to take effect Note When the SSH server is restarted or disabled any CLI sessions running over SSH will be terminated immediately Chapter 3 Managing the Service Processor 31 32 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 CHAPTER 4 Managing Devices This chapter contains information on ILOM properties for Oracle s Sun Netra T5440 server that augment the array of properties that are common to ILOM on other platforms In particular this chapter covers properties in the SYS namespa
15. Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server NS 2 Sun Part No 820 4444 11 April 2010 Revision A Copyright 2008 2010 Oracle and or its affiliates All rights reserved This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws Except as expressly permitted in your license agreement or allowed by law you may not use copy reproduce translate broadcast modify license transmit distribute exhibit perform publish or display any part in any form or by any means Reverse engineering disassembly or decompilation of this software unless required by law for interoperability is prohibited The information contained herein is subject to change without notice and is not warranted to be error free If you find any errors please report them to us in writing If this is software or related software documentation that is delivered to the U S Government or anyone licensing it on behalf of the U S Government the following notice is applicable U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific ja ieee oleae regulations As such the use duplic
16. able or Re Enable Network Access to the SP Using the CLI Use the SP network state property to enable or disable the service processor s network interface Type gt set SP network state value where value can be enabled default or disabled V To Display the DHCP Server s IP Address To display the IP address of the DHCP server that provided the dynamic IP address requested by the service processor view the dhcp_server_ip property To see the dhcp_server_ip property do the following Type gt show SP network For example gt show SP network pendingipaddress pendingipdiscovery dhcp pendingipgateway pendingipnetmask state enabled Commands cd set show SP network Targets Properties commitpending dhcp_server_ip 10 8 31 5 ipaddress 10 8 31 188 ipdiscovery dhcp ipgateway 10 8 31 248 ipnetmask 255 255 252 0 macaddress 00 14 4F 7E 83 4F 10 8 31 188 10 8 31 248 255 255 252 0 Chapter 3 Cannot show property Managing the Service Processor 27 Managing SSH Server Settings m To Change the Type of SSH Keys Using the CLI on page 28 m To Generate a New Set of SSH Keys Using the CLI on page 28 m To Restart the SSH Server Using the CLI on page 28 a To Enable or Disable the SSH Service Using the CLI on page 29 m To Manage SSH Server Settings Using the Web Interface on page 30 Vv To Change th
17. ag trigger user reset power on reset show HOST diag trigger user reset power on reset V To Choose the Amount of Verbosity in Diagnostic Output Using the CLI Use the HOST diag verbosity property to specify the verbosity level of the output from POST diagnostics if diagnostics are enabled 12 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Type gt set HOST diag verbosity value where value is one of the following a none Diagnostics do not print any output on the system console when running unless a fault is detected m min Diagnostics print a limited amount of output on the system console m max Diagnostics print full output on the system console including the name and results of each test being run m normal Diagnostics print a moderate amount of output on the system console the default value a debug Diagnostics print extensive debugging output on the system console including devices being tested and debug output of each test V To Manage Diagnostics Settings Using the Web Interface This procedure describes how to view and configure diagnostics settings REFRESH LOG OUT Role User Administrator root SP Hostname SUNSP00144F3F8CAF Sun Integrated Lights Out Manager att 7 onporng 1 46 hr Jr Remote Control Maintenance Remote Power Control Diagnostics Host Control Boot Mode Settings
18. ame Note Characters display differently depending on browser settings If characters do not display correctly change the character encoding in your browser to Unicode UTF 8 x Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Related Documentation The following table lists the documentation for this product The online documentation is available at http docs sun com app docs prod server nebs Part Application Title Number Format Location Planning Sun Netra T5440 Server Site Planning Guide 820 4441 PDF Online Installation Sun Netra T5440 Server Installation Guide 820 4442 PDF HTML Online Administration Sun Netra T5440 Server Administration Guide 820 4443 PDF HTML Online ILOM Reference Oracle Integrated Lights Out Manager ILOM 2 0 820 4444 PDF HTML Online Supplement for the Sun Netra T5440 Server ILOM Reference Oracle Integrated Lights Out Manager ILOM 3 0 820 6891 PDF HTML Online Supplement for the Sun Netra T5440 Server Issues amp Updates Sun Netra T5440 Server Service Manual 820 4445 PDE HTML Online Service Sun Netra T5440 Server Safety and Compliance 820 4446 PDE HTML Online Guide Compliance Sun Netra T5440 Server Product Notes 816 4447 PDF HTML Online Overview Sun Netra T5440 Server Getting Started Guide 820 3016 Printed Ship kit amp PDF Online Preface xi Documentation Support and Training Sun Function URL Document
19. ate SP services snmp SP alertmgmt rules SP clients smtp address SP services snmp vl v2c v3 SP alertmgmt rules SP services snmp port 52 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 TABLE B 3 ALOM CMT Variable ALOM CMT Variables and Comparable ILOM Properties Continued Comparable ILOM Property netsc_dhcp netsc_commit netsc_enetaddr netsc_ipaddr netsc_ipgateway netsc_ipnetmask sc_backupuserdata sc_clieventlevel sc_cliprompt sc_clitimeout sc_clipasswdecho sc_customerinfo sc_escapechars sc_powerondelay sc_powerstatememory ser_baudrate ser_data ser_parity ser_stopbits sys_autorestart sys_autorunonerror sys_eventlevel sys_enetaddr SP network pendingipdiscovery SP network commitpending SP network macaddress SP network pendingipaddress SP network pendingipgateway SP network pendingipnetmask SP policy BACKUP_USER_DATA N A N A N A N A SP system_identifier SP console escapechars SP policy HOST_POWER_ON_DELAY SP policy HOST_LAST_POWER_STATE SP serial external pendingspeed N A SP serial external pendingparity SP serial external pendingstopbits SP autorestart SP autorunonerror N A HOST macaddress Appendix B ALOM CMT Compatibility Shell 53 54 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Index Symbols HOST autorestar
20. ation disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle USA Inc 500 Oracle Parkway Redwood City CA 94065 This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including applications which may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible to take all appropriate fail safe backup redundancy and other measures to ensure the safe use Oracle orporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications Oracle and Java are registered trademarks of Oracle and or its affiliates Other names may be trademarks of their respective owners AMD Opteron the AMD logo and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc UNIX is a registered trademark licensed th
21. ation http docs sun com Support http www sun com support Training http www sun com training xii Documentation Feedback Submit comments by clicking the Feedback link at http docs sun com Please include the title and part number of your document with your feedback Oracle Integrated Lights Out Manager 2 0 Supplement for the Sun Netra T5440 Server part number 820 4444 11 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 CHAPTER 1 ILOM for the Sun Netra T5440 Server This chapter introduces ILOM for Oracle s Sun Netra T5440 server This chapter contains the following sections m SPARC Specific ILOM Features on page 1 m ILOM Features Not Supported in Sun Netra Servers on page 1 SPARC Specific ILOM Features ILOM operates on many platforms supporting features that are common to all platforms There are some ILOM features that belong to a subset of platforms and not to all This document describes features that belong to the Sun Netra T5440 server augmenting the set of features described in the Sun Integrated Lights Out Manager 2 0 User s Guide ILOM Features Not Supported in Sun Netra Servers Among the ILOM features supported on other platforms ILOM does not support the following features on the server m ILOM Remote Console m Chassis Monitoring Module CMM features such as single sign on The remainder of thi
22. ce Managing Virtual Keyswitch Settings a To Control the Virtual Keyswitch Using the CLI on page 33 m To Control the Virtual Keyswitch Using the Web Interface on page 34 V To Control the Virtual Keyswitch Using the CLI Use the SYS setkeyswitch_state property to control the virtual keyswitch position of the system 33 At the gt prompt type the following command gt set SYS keyswitch_state value where the setkeyswitch_state property has the following values Option Description normal The system can power itself on and start the boot process standby The system cannot power itself on diag The system can power itself on using preset values of diagnostic properties HOST diag level max HOST diag mode max HOST diag verbosity max to provide thorough fault coverage This option overrides the values of diagnostic properties that you might have set locked The system can power itself on however you are prohibited from updating any of the flash devices or setting HOST send_break_action break V To Control the Virtual Keyswitch Using the Web Interface You can use the web interface to control the virtual keyswitch position of the system REFRESH LOG OUT Role User Administrator root SP Hostname SUNSPO0144F 3F8CAF Sun Integrated Lights Out Manager Remote Power Control Diagnostics Host Control Boot Mode Settings Keyswitch Keyswitch Configure keysw
23. d virtual keyswitch to standby stby powers off the server Before powering off the host server ALOM CMT asks for a confirmation setsc param value Sets the specified ALOM set target property value CMT parameter to the assigned value setupsc Runs the interactive No equivalent in ILOM configuration script This script configures the ALOM CMT configuration variables Appendix B ALOM CMT Compatibility Shell 45 TABLE B 2 ALOM CMT Shell Commands by Function Continued ALOM CMT Command Summary Comparable ILOM Command showplatform v Displays information show HOST about the host system s hardware configuration and whether the hardware is providing service The v option displays verbose information about the displayed components showfru Displays information No equivalent in ILOM about the field replaceable units FRUs in a host server showusers g lines Displays a list of users show SP sessions currently logged in to ALOM CMT The display for this command has a similar format to that of the UNIX command who The g option pauses the display after the number of lines you specify for lines showhost version Displays version show HOST information for host side components showkeyswitch Displays status of virtual show SYS keyswitch_state keyswitch showsc param Displays the current show target property non volatile read only memory NVRAM configuration parameters showdate Displays t
24. d Disk 0 7 Presence Sensor TABLE A 2 Indicators on Sun Netra T5440 Server Name Path Description LOCATE SYS LOCATE Locate Indicator ACT SYS ACT System Power Activity Indicator SERVICE SYS SERVICE Service Indicator 38 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 TABLE A 2 Indicators on Sun Netra T5440 Server Continued Continued Name Path Description CRITICAL SYS CRITICAL_ALARM Critical Alarm MAJOR SYS MAJOR_ALARM Major Alarm MINOR SYS MINOR_ALARM Minor Alarm USER SYS USER_ALARM User alarm BRn CH0 D0 SERVICE SYS MB CMP0 BRn CH0 D0 SERVICE Branch Service Indicator HDDn SERVICE SYS HDDn SERVICE Hard Disk 0 7 Service Indicator HDDn OK2RM SYS HDDn OK2RM Hard Disk 0 7 Okay to Remove Indicator Appendix A IPMI Sensor Reference 39 40 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 APPENDIX B ALOM CMT Compatibility Shell Oracle s Sun Integrated Lights Out Manager ILOM for Oracle s Sun Netra T5440 server supports some of the features of the ALOM CMT command line interface by means of a compatiblity shell There are significant differences between ILOM and ALOM CMT This appendix describes those differences a Backward Compatibility Limits on page 41 m Creating an ALOM CMT Shell on page 42 a ILOM and ALOM CMT Command Comparison
25. e Type of SSH Keys Using the CLI Use the set SP services ssh generate_new_key_type command to change the type of Secure Shell SSH host keys generated on your server After changing the type you must use the set SP services ssh generate_new_key_action command to generate a new set of keys of the new type Type gt set SP services ssh generate new key type value where value can be rsa or dsa Vv To Generate a New Set of SSH Keys Using the CLI Use the set SP services ssh generate new key _ action command to generate a new set of Secure Shell SSH host keys Type gt set SP services ssh generate _new_key action true V To Restart the SSH Server Using the CLI Use the set SP services ssh restart_sshd_action command to restart the SSH server after you have generated new host keys using the set SP services ssh generate_new_key_action command This reloads the keys into the server s dedicated data structure in memory 28 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Type gt set SP services ssh restart_sshd_action true V To Enable or Disable the SSH Service Using the CLI Use the SP services ssh state property with the set command to enable or disable the SSH service If the SSH service has been disabled you can re enable it through the Serial Management SER MGT port or the ILOM web interface Type gt set SP serv
26. e is Hash Period The sequence can be customized Note Changing the escape character does not take effect in a currently active console session Changing Configuration Policy Settings This section describes managing configuration system policies using ILOM m To Specify Backup of the User Database Using the CLI on page 21 m To Specify Host Power On Policy Using the CLI on page 22 a To Disable or Re Enable Power On Delay Using the CLI on page 23 m To Manage Configuration Policy Settings Using the Web Interface on page 23 Vv To Specify Backup of the User Database Using the CLI The SP policy BACKUP_USER_DATA property specifies whether the local user database on ILOM that is user password and permission information should be backed up When this property is set to enable this data is backed up on the removable system configuration card SCC PROM on the system Chapter 3 Managing the Service Processor 21 Type gt set SP policy BACKUP_USER_DATA value where the value can be one of the following m enabled Backs up the user database to the SCC This is the default value a disabled No backup For example if you want the local user database on ILOM to be backed up type the following command gt set SP policy BACKUP_USER_DATA enabled YV To Specify Host Power On Policy Using the CLI Use the SP policy HOST_LAST_POWER_STATE property to control the behavior
27. emptes d erreurs et vous invite le cas ch ant a lui en faire part par crit Si ce logiciel ou la documentation qui l accompagne est conc d sous licence au Gouvernement des Etats Unis ou toute entit qui d livre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats Unis la notice suivante s applique U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific Pell os regulations As such the use duplication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 Ce logiciel ou mat riel a t d velopp pour un usage g n ral dans le cadre d applications de gestion des informations Ce logiciel ou mat riel n est pas con u ni n est destin tre utilis dans des applications risque notamment dans des applications pouvant causer des dommages corporels Si vous utilisez ce logiciel ou mat riel dans le cadre d applications dangereuses il est de vo
28. ensor USB Port 0 1 Current Sensor Power Supply 0 1 Power Within Specification Sensor CPU Core Voltage Threshold Sensor CPU Core Voltage Threshold Sensor Left Branch Voltage Threshold Sensor Right Branch Voltage Threshold Sensor 37 TABLE A 1 Sensors on the Sun Netra T5440 Server Continued Name Path Description VCOREL_POK SYS MB VCOREL_POK Core Power Within Specification Sensor VCORER_POK SYS MB VCORER_POK Core Power Within Specification Sensor VMEML_POK SYS MB VMEML_POK Left Branch Power Within Specification Sensor VMEMR_POK SYS MB VMEMR_POK Right Branch Power Within Specification Sensor BRn CH0 D0 PRSNT SYS MB CMP0O BRn CH0 D0 PRSNT Branch 0 3 Presence Sensor PSn VOLT_FAULT PSn TEMP_FAULT PSn CUR_FAULT PSn DC_POK PSn FAN_FAULT T_TCORE T_BCORE PSn PRSNT BRn CH0 D0 T_AMB HDDn PRSNT SYS PSn VOLT_FAULT SYS PSn TEMP_FAULT SYS PSn CUR_FAULT SYS PSn DC_POK SYS PSn FAN_FAULT SYS MB CMP0 T_TCORE SYS MB CMP0 T_BCORE SYS PSn PRSNT SYS MB CMP0 BRn CH0 D0 T_AMB SYS HDDn PRSNT Power Supply 0 1 Voltage Fault Sensor Power Supply 0 1 Temperature Fault Sensor Power Supply 0 1 Current Fault Sensor Power Supply 0 1 DC Power Sensor Power Supply 0 1 Fan Fault Sensor Top of Core Temperature Sensor Bottom of Core Temperature Sensor Power Supply 0 1 Presence Sensor Branch 0 3 Temperature Sensor Har
29. he command sets of ALOM CMT and the default ILOM CLI command set Only the supported ALOM CMT command options are listed in TABLE B 2 Where there are ALOM CMT command line arguments that have no corresponding ILOM properties those ALOM CMT arguments have been omitted The command set of the ALOM compatibility shell provides a close approximation of the equivalent commands and arguments where supported in ALOM CMT 44 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 TABLE B 2 ALOM CMT Shell Commands by Function ALOM CMT Command Summary Comparable ILOM Command Configuration Commands password Changes the login set SP users username password password of the current user restartssh Restarts the SSH server so set SP services ssh restart_sshd_action that new host keys true generated by the ssh keygen command are reloaded setalarm critical Turns the alarm and set SYS MINOR ALARM value on major minor user on loff associated LED on and off setdate mmdd HHMM Sets ALOM CMT date and set SP clock datetime value mmddHHMM cc yy SS time setdefaults a Resets all ALOM CMT set SP reset_to_defaults all configuration parameters to their default values The a option resets the user information to the factory default one admin account only setkeyswitch Set the status of the virtual set SYS keyswitch_state value normal stby diag keyswitch Setting the locke
30. he ALOM CMT show SP clock datetime date ALOM CMT time is expressed in Coordinated Universal Time UTC rather than local time The Solaris OS and ALOM CMT time are not synchronized 46 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 TABLE B 2 ALOM CMT Command Summary ALOM CMT Shell Commands by Function Continued Comparable ILOM Command ssh keygen 1 t rsa dsa usershow username useradd username userdel username userdel y username userpassword username userperm username c u a r Log Commands showlogs p logtype pl consolehistory b lines e lines v g lines boot run Generates Secure Shell SSH host keys and displays the host key fingerprint on the SC Displays a list of all user accounts permission levels and whether passwords are assigned Adds a user account to ALOM CMT Deletes a user account from ALOM CMT The y option enables you to skip the confirmation question Sets or changes a user password Sets the permission level for a user account Displays the history of all events logged in the ALOM CMT RAM event log or major and critical events in the persistent log The p option selects whether to display entries only from the RAM event log logtype r or the persistent event log logtype p Displays the host server console output buffers show SP services ssh key
31. he kmdb debugger then specifying the send_break_action break brings the server into debug mode Specify send_break_action dumpcore to force a core dump 14 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 Type gt set HOST send_break_action value where value is one of the following m break Sends a break to the host m dumpcore Forces a panic core dump of the managed system OS not supported by all OS versions V To Display Host Status Information Using the CLI Use the show HOST status command to display information about the host server s platform ID and status Type gt show HOST status The command returns information similar to the following gt show HOST status Properties status Solaris Running Commands cd set show show gt Chapter 2 Managing the Host 15 16 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 CHAPTER 3 Managing the Service Processor This chapter contains information on ILOM properties on the Sun Netra T5440 server that augment the array of properties that are common to ILOM on other platforms In particular this chapter covers properties in the SP namespace This chapter consists of Storing Customer Information on page 17 Changing Service Processor Settings to Factory Defaults on page 19 Modifying C
32. ices ssh state wilue where value is enabled default or disabled Chapter 3 Managing the Service Processor 29 V To Manage SSH Server Settings Using the Web Interface Role User Admin root SP ame SUNSPO0144 Sun Integrated Lights Out Manager System Management Access Alert Management Network Serial Port Clock Settings Syslog SMTP Clier Web Server SNMP SSL Certificate SSH Server SSH Server Settings Configure Secure Shell server access and key generation Newly generated keys are not used until the SSH server is restarted When the SSH server is restarted or disabled any CLI sessions running over SSH will be immediately terminated SSH Server Enabled ba RSA Key RSA Fingerprint e1 92 e7 b2 dc 74 95 e1 7ef9 18 3a ab 54 7e 16 RSA Key Length 1024 bits AAAAB3NZzaClyc2EAAAABIwAAATEAvVERT9pFfm3sUg78KI7Qr lwslmbwv15501 h Tj 1jWlebI8 ujvHMn3z1hOROURRJ c V9KymcJnRWel jWRjme UkIJWWezz9xg7Mi j Ms jqHObnwh61 6F rSDhpcRVOkKNS7L8yDT5 8HgMINy 6pprakG7Yd9cHek221u0 ErEqUUU RSA Public Key DSA Key DSA Fingerprint d7 03 28 55 cc cc 4f c5 06 99 da 7b ec 4c 77 la DSA Key Length 1024 bits AAAAB3NzaClkc 3MAAACRA ThgDF t1lghTF1L1tvSHN4ELU5ZO0 mXOKuL7EdkKWne 0 iqTgiqo6 fupvBsB1k29Uf VJAP2FEnw6kA0 GgFN2UC3yzr1MtLw4Ufg00bNcZwLol0Sq8ETZGypLL1H80F 0 xJzGtaqknKxSALcy GW f4WMB100045bknA3AY jszTIehxnRD ARAAF DAvfDKEm 3 xqh34ThFCq7YhnxHwAAAIB5 aiYNHe0 GgR8SG19NvDDDicC70p0x9irFR r1VO11ZCPcoCV
33. ilable_power displays the input power capacity in watts that is available to system components m permitted_power displays the maximum power consumption in watts expected Vv To View the Total Power Consumed By the System The value of SYS VPS is equivalent to the value of SP powermgmt actual_power Chapter 3 Managing the Service Processor 25 Type gt show SYS VPS For example gt show SYS VPS SYS VPS Targets Properties type Power Unit class Threshold Sensor value 306 800 Watts upper_nonrecov_threshold 1451 40 Watts upper_critical_threshold 1433 70 Watts upper_noncritical_threshold 1298 00 Watts lower_noncritical_threshold N A lower_critical_threshold N A lower_nonrecov_threshold N A Commands cd show V To View Power Management Properties Using the Web Interface 1 26 Log in to the ILOM web interface as Administrator root to open the web interface Select System Monitoring gt Power Management View the Actual Power consumption View the Permitted Power consumption View the Available Power Managing Network Access This section describes managing network access to the SP using ILOM To Disable or Re Enable Network Access to the SP Using the CLI on page 27 To Display the DHCP Server s IP Address on page 27 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 V To Dis
34. ing a script or similar tasks For example if the OpenBoot settings have become corrupt you can set the bootmode state property to reset_nvram then reset the server with factory default OpenBoot settings Service personnel might instruct you to use the bootmode script property for problem resolution The full extent of script capabilities are not documented and exist primarily for debugging Because bootmode is intended to be used for a single boot only to correct a problem with the OpenBoot or LDoms settings the bootmode takes effect for a single boot only Additionally to prevent an administrator from setting a bootmode state property and forgetting about it a bootmode state property expires if the host is not reset within 10 minutes of the bootmode state property being set V To Manage the Host s Boot Mode LDoms Configuration Using the CLI Type gt set HOST bootmode config value where the config property takes a configname value such as a named logical domain configuration downloaded to the SP using the Logical Domains software For example if you have created a logical domain configuration called 1dm set1 gt bootmode config l1dm set1 To return the boot mode config to the factory default configuration specify factory default For example gt bootmode config factory default Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 20
35. itch Keyswitch l Normal Cave 1 Log into the ILOM web interface as Administrator root to open the web interface 2 Select Remote Control gt Keyswitch 34 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 3 Select the Keyswitch state value 4 Click Save Chapter 4 Managing Devices 35 36 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 APPENDIX A IPMI Sensor Reference Your server includes a number of IPMI compliant sensors and indicators that measure voltages temperature ranges and detection of when components are installed and removed Indicators such as Light Emitting Diodes Lads notify you of important server conditions such as when service is required TABLE A 1 Sensors on the Sun Netra T5440 Server Name Path Description V_ 3V3_STBY SYS MB V_ 3V3_STBY 3 3V Standby Voltage Threshold Sensor V_ 3V3 MAIN SYS MB V_ 3V3 MAIN 3 3V Main Voltage Threshold V_ 12V0_MAIN V_VBAT V_VDDIO T_AMB I_USBn PSn AC_POK V_VCOREL V_VCORER V_VMEML V_VMEMR SYS MB V_ 12V0_MAIN SYS MB V_VBAT SYS MB V_VDDIO SYS MB T_AMB SYS MB I_USBn SYS PSn AC_POK SYS MB V_VCOREL SYS MB V_VCORER SYS MB V_VMEML SYS MB V_VMEMR Sensor 12V Main Voltage Threshold Sensor Voltage Threshold Sensor Voltage Threshold Sensor Ambient Temperature Threshold S
36. m all Reset clear the user database Chapter 3 Managing the Service Processor 19 2 Reset the service processor so that the new property value can take effect V To Reset the Service Processor Settings to Factory Defaults Using the Web Interface Role User Administrator root SP Hostname SUNSP00144F3F8CAF Sun Integrated Lights Out Manager Maintenance Firmware Upgrade Reset SP Configuration Management Configuration Management Manage the system configuration on this page Clicking Reset Defaults will restore the system configuration to factory settings Reset Defaults None Reset Defaults 1 Log into the ILOM web interface as Administrator root to open the web interface 2 Select Maintenance gt Configuration Management 3 Select a Reset Defaults value 4 Click Save Modifying Console Escape Characters This section describes creating new character combinations for use as escape characters 20 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 V To Change Console Escape Characters Using the CLI Use the SP console escapechars property to change the escape character sequence to switch from a system console session back to ILOM Type gt set SP console escapechars x where xx are any printable characters The sequence is limited to two characters The second character is always Period The default valu
37. naging System User Interactions 15 v To Enable the System to Send a Break Signal or Force a Core Dump Using the CLI 15 v To Display Host Status Information Using the CLI 15 3 Managing the Service Processor 17 Storing Customer Information 17 v To Change Customer FRU Data Using the CLI 18 v To Change System Identification Information Using the CLI 18 v To Change Customer Identification Information Using the Web Interface 18 Changing Service Processor Settings to Factory Defaults 19 v To Reset the Service Processor Settings to Factory Default Values Using the CLI 19 v To Reset the Service Processor Settings to Factory Defaults Using the Web Interface 20 Modifying Console Escape Characters 20 v To Change Console Escape Characters Using the CLI 21 Changing Configuration Policy Settings 21 iv Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 To Specify Backup of the User Database Using the CLI 21 To Specify Host Power On Policy Using the CLI 22 4a lt To Disable or Re Enable Power On Delay Using the CLI 23 v To Manage Configuration Policy Settings Using the Web Interface 23 Displaying Power Management Metrics 24 v To View Power Management Properties Using the CLI 25 v To View the Total Power Consumed By the System 25 v To View Power Management Properties Using the Web Interface 26 Managing Network Access 26 v To Disable or Re Enable Network Access to the SP Using the CL
38. ntenus produits ou services tiers ou leur utilisation Ka m Adobe PostScript Contents Preface ix ILOM for the Sun Netra T5440 Server 1 SPARC Specific ILOM Features 1 ILOM Features Not Supported in Sun Netra Servers 1 Managing the Host 3 Managing Host Boot Mode 3 Boot Mode 4 v To Manage the Host s Boot Mode LDoms Configuration Using the CLI 4 To Manage the Host s Boot Mode Script Using the CLI 5 To Change the Host s Boot Mode Behavior at Reset Using the CLI 5 To Display Host s Boot Mode Expiration Date Using the CLI 6 lt lt lt lt To Change Boot Mode Configuration Settings Using the Web Interface 6 Viewing Host Information and Setting System Policy Concerning Error Conditions 7 v To Display the Host s MAC Address Using the CLI 8 v To Display the Host s OpenBoot Version Using the CLI 8 v To Display the Host s POST Version Using the CLI 8 v To Specify Host Behavior When the Watchdog Timer Expires Using the CLI 9 v To Specify Host Behavior When an Error Is Discovered During Diagnostics Using the CLI 9 v To View Host Information Using the Web Interface 9 Managing Host Diagnostics 11 v To Specify the Level of Diagnostics Using the CLI 11 v To Change the Diagnostics Mode Using the CLI 11 v To Specify Diagnostic Trigger Conditions Using the CLI 12 v To Choose the Amount of Verbosity in Diagnostic Output Using the CLI 13 v To Manage Diagnostics Settings Using the Web Interface 13 Ma
39. on about Oracle Integrated Lights Out Manager ILOM for the Sun Netra T5440 server from Oracle The ILOM service processor enables you to remotely manage and administer your servers You should be an experienced system administrator with a knowledge of UNIX commands Using UNIX Commands This document might not contain information on basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices See the following for this information m Software documentation that you received with your system m Oracle Solaris OS documentation which is at http docs sun com Shell Prompts Shell Prompt C shell C shell superuser Bourne shell and Korn shell Bourne shell and Korn shell superuser ILOM service processor OpenBoot PROM firmware machine name machine name gt ok Typographic Conventions Typeface Meaning Examples AaBbCc123 The names of commands files and directories on screen computer output AaBbCc123 What you type when contrasted with on screen computer output AaBbCc123 Book titles new words or terms words to be emphasized Replace command line variables with real names or values Edit your login file Use 1s a to list all files You have mail su Password Read Chapter 6 in the User s Guide These are called class options You must be superuser to do this To delete a file type rm filen
40. onfigure identification information Customer FRU Data my fru data SP Hostname SUNSP00144F3F8CAF 18 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 ILOM provides features that enable you to store information on FRUs and the SP 1 Log into the ILOM web interface as Administrator root to open the web interface 2 Select System Information gt Identification Information 3 Edit the Customer FRU data field 4 View the SP Hostname 5 Edit the SP System Identifier field 6 Click Save Changing Service Processor Settings to Factory Defaults This section describes how to set service processor settings back to the factory defaults m To Reset the Service Processor Settings to Factory Default Values Using the CLI on page 19 m To Reset the Service Processor Settings to Factory Defaults Using the Web Interface on page 20 To Reset the Service Processor Settings to Factory Default Values Using the CLI Use the reset_to_defaults property to set all ILOM configuration properties back to their factory default values The a11 option sets the ILOM configuration and all user information back to the factory default values 1 At the gt prompt type the following command gt set SP reset_to_defaults all where for reset_to_defaults can be set to one of the following m none Make no changes m configuration Preserve the user database
41. onsole Escape Characters on page 20 Changing Configuration Policy Settings on page 21 Displaying Power Management Metrics on page 24 Managing Network Access on page 26 Managing SSH Server Settings on page 28 Storing Customer Information This section describes ILOM features that enable you to store information for purposes such as inventory control or site resource management on the SP and FRU PROMs To Change Customer FRU Data Using the CLI on page 18 To Change System Identification Information Using the CLI on page 18 To Change Customer Identification Information Using the Web Interface on page 18 V To Change Customer FRU Data Using the CLI Use the SP customer_frudata property to store information in all FRU PROMs Type gt set SP customer _frudata data Note The data string data must be enclosed in quote marks Vv To Change System Identification Information Using the CLI Use the SP system_identifier property to store customer identification information Type gt set SP system_identifier daia V To Change Customer Identification Information Using the Web Interface REFRESH LOG OUT Role User Administrator root SP Hostname SUNSPO0144F3F8CAF Sun Integrated Lights Out Manager Versions Session Time Out Components Fault Management Identification Information Identification Information C
42. ote state reset_nvram will return to normal after the next server reset or 10 minutes see expires property in the Integrated Lights Out Management 2 0 User s Guide config and script properties do not expire and will be cleared upon the next server reset or manually by setting string to V To Display Host s Boot Mode Expiration Date Using the CLI Atthe gt prompt type the following command gt show HOST bootmode expires Properties expires Thu Oct 18 18 24 16 2007 where expires is the date at which the current bootmode state expires Vv To Change Boot Mode Configuration Settings Using the Web Interface REFRESH LOG OUT Role User Administrator root SP Hostname SUNSPO0144F3F8CAF Sun Integrated Lights Out Manager Remote Control Remote Power Control Diagnostics Host Control Boot Mode Settings Keyswitch Boot Mode Configure boot mode settings Select an option for state either Normal or Reset_nvram Enter the boot script and LDOM configuration State Normal v Expiration Date Tue Jan 19 03 14 07 2038 Script my script LDOM Config save ILOM provides several ways to configure the server s firmware environment There are four aspects to configuring the boot mode Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 State Expiration Date Script LDom Configuration Log into the
43. r this property type gt show HOST macaddress V To Display the Host s OpenBoot Version Using the CLI The HOST obp_version property displays information about the version of OpenBoot on the host 1 To view the current setting for this property type gt show HOST obp_ version V To Display the Host s POST Version Using the CLI The HOST post_version property displays information about the version of POST on the host To view the current setting for this property type gt show HOST post_version Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 V To Specify Host Behavior When the Watchdog Timer Expires Using the CLI Use the HOST autorestart property to specify how ILOM should handle expiration of the Solaris watchdog timer To set this property type gt set HOST autorestart value where value can be as follows m none ILOM takes no action other than to issue a warning m reset ILOM attempts to reset the system when the Solaris watchdog timer expires the default a dumpcore ILOM attempts to force a core dump of the OS when the watchdog timer expires Vv To Specify Host Behavior When an Error Is Discovered During Diagnostics Using the CLI Use the HOST autorunonerror property to specify whether the host should continue to boot after system diagnostics have discovered an error To set this propert
44. rator Set role to Administrator gt set SP users admin cli_mode alomSet cli mode to alom Enter new password again Created SP users admin Note The asterisks in the example will not appear when you enter your password You can combine the create and set commands on a single line gt create SP users admin role Administrator cli_mode alomEnter new password xxxxx Creating user Creating user Enter new password again Created SP users admin KKKKKKKK Appendix B ALOM CMT Compatibility Shell 43 3 Log out of the root account after you have finished creating the admin account 4 Log in to the ALOM CLI shell indicated by the sc gt prompt from the ILOM login prompt SUNSPxxxx xxxxxxxxx login admin Password Waiting for daemons to initialize Daemons ready Sun TM Integrated Lights Out Manager Version 2 0 0 0 Copyright 2007 Sun Microsystems Inc All rights reserved Use is subject to license terms sc gt Using the ALOM CMT compatibility shell with few exceptions you can use commands that resemble the commands of ALOM CMT Remember that the ALOM CMT compatibility shell is an ILOM interface The comparisons between the ILOM CLI and ALOM CMT compatibility CLI are described in ILOM and ALOM CMT Command Comparison on page 44 ILOM and ALOM CMT Command Comparison The following table provides a command by command comparison between t
45. rough X Open Company Ltd This software or hardware and documentation may provide access to or information on content products and services from third parties Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third party content products and services Oracle Corporation and its affiliates will not be responsible for any loss costs or damages incurred due to your access to or use of third party content products or services Copyright 2008 2010 Oracle et ou ses affili s Tous droits r serv s Ce logiciel et la documentation qui Lar ompaghe sont pees par les lois sur la propri t intellectuelle Ils sont conc d s sous licence et soumis des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer ex cuter publier ou afficher le logiciel m me partiellement sous quelque forme et par uelque proc d que ce soit Par ailleurs il est interdit de proc der a toute ing nierie inverse du logiciel de le d sassembler ou de le d compiler except a es fins d interoperabilit avec des logiciels tiers ou tel que prescrit par la loi Les informations fournies dans ce document sont susceptibles de modification sans pr avis Par ailleurs Oracle Corporation ne garantit pas qu elles soient ex
46. s document describes the ILOM features that are supported on the server Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 CHAPTER 2 Managing the Host This chapter contains information on ILOM features on the Sun Netra T5440 server that augment the array of properties that are common to ILOM on other platforms In particular this chapter describes the properties in the HOST namespace Topics include m Managing Host Boot Mode on page 3 a Viewing Host Information and Setting System Policy Concerning Error Conditions on page 7 m Managing Host Diagnostics on page 11 m Managing System User Interactions on page 15 Managing Host Boot Mode Use the remote control properties to specify how ILOM handles boot m To Manage the Host s Boot Mode LDoms Configuration Using the CLI on page 4 a To Manage the Host s Boot Mode Script Using the CLI on page 5 m To Change the Host s Boot Mode Behavior at Reset Using the CLI on page 5 a To Display Host s Boot Mode Expiration Date Using the CLI on page 6 m To Change Boot Mode Configuration Settings Using the Web Interface on page 6 Boot Mode Boot mode bootmode properties enable you to override the default method the server uses when it boots This ability is useful to override particular OpenBoot or LDoms settings that might be incorrect to set up OpenBoot variables us
47. s dsa show SP services ssh keys rsa show SP users create SP users username delete SP users username delete script SP users username set SP users username password set SP users username role permissions where permissions are Administrator or Operator show SP logs event list No equivalent in ILOM Appendix B ALOM CMT Compatibility Shell 47 TABLE B 2 ALOM CMT Shell Commands by Function Continued ALOM CMT Command Summary Comparable ILOM Command Status and Control Commands showenvironment shownetwork v console f break c break D bootmode normal reset_nvram config configname bootscript string Displays the show o table level all SYs environmental status of the host server This information includes system temperatures power supply status front panel LED status hard disk drive status fan status voltage and current sensor status Displays the current show SP network network configuration information The v option shows additional information about your network including information about your DHCP server Connects to the host start SP console system console The option forces the console write lock from one user to another Drops the host server from set HOST send_break_action break running the Solaris OS software into OpenBoot PROM or kmdb depending upon the mode in which the Solaris software was booted set
48. sable or Re Enable Power On Delay Using the CLI Use the SP policy HOST_POWER_ON_DELAY property to cause the server to wait for a short time before powering on automatically The delay is a random interval of one to five seconds Delaying the server poweron helps minimize current surges on the main power source This poweron delay is important when multiple servers in racks power on after a power outage This property takes effect only if SP policy HOST_LAST_POWER_STATE is set to enabled Type gt set SP policy HOST _POWER_ON_DELAY value where value can be enabled or disabled default V To Manage Configuration Policy Settings Using the Web Interface REFRESH LOG OUT Role User Administrator root SP Hostname SUNSPOO144F 3F8CAF Sun Integrated Lights Out Manager Configuration j System Management Access Alert Management Network Serial Port Clock Settings Syslog SMTP Client Policy Policy Configuration Configure system policies from this page To modify a policy select the radio button next to that policy then choose Enable or Disable from the Action drop down list Service Processor Policies Actions v r ASE FE AR D D FE A A ON A ON OA PEN Weal Heat i il i i i i i i i i re 8 Description Cc Auto power on host on boot enabling this policy disables Set host power to last power state policy Disabled C Set host power to last power s
49. t property 9 HOST autorunonerror property 9 HOST macaddress property 8 HOST send_break_action property 15 HOST status property 15 HOST bootmode config property 4 HOST bootmode expires property 6 HOST bootmode script property 5 HOST bootmode state property 5 HOST diag level property 11 HOST diag mode property 11 HOST diag trigger property 12 HOST diag verbosity property 13 SP customer_frudata property 18 SP reset_to_defaults property 19 SP system_identifier property 18 SP console escapechars property 21 SP policy BACKUP_USER_DATA property 21 SP policy HOST_LAST_POWER_STATE property 22 SP policy HOST_POWER_ON_DELAY property 23 SP policy HOST_POWER_ON_D 23 SP services ssh generate_new_key_action property 28 T AY property SP services ssh generate_new_key_type property 28 SP services ssh restart_sshd_action property 28 29 SP services ssh state property 29 SYS keyswitch_state property 33 A ALOM commands setalarm 45 backing up user data 21 boot mode about 4 managing configuration 4 managing reset 5 managing script 5 D defaults resetting 19 F factory defaults 19 l ILOM properties HOST autorestart 9 HOST autorunonerror 9 HOST macaddress 8 HOST send_break_action 15 HOST status 15 HOST bootmode config 4 55 HOST bootmode expires 6 HOST bootmode script 5 HOST bootmode state
50. tate on boot enabling this policy disables Auto power on host policy Disabled Set to delay host power on Disabled Enabled Cc Set to enable backing up of user account info to SCC card 1 Log into the ILOM web interface as Administrator root to open the web interface Chapter 3 Managing the Service Processor 23 2 Select Configuration gt Policy 3 Click the Policy radio button of the policy you want to change 4 Select an Action value to apply the Action enable or disable you have chosen Displaying Power Management Metrics This section describes using ILOM to view the server s power metrics Topics include a To View Power Management Properties Using the CLI on page 25 a To View the Total Power Consumed By the System on page 25 a To View Power Management Properties Using the Web Interface on page 26 24 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 V To View Power Management Properties Using the CLI Type gt show SP powermgmt For example gt show SP powermgmt SP powermgmt Targets Properties actual_power 280 permitted_power none available power none control local policy performance regulated_budget none elastic_budget none Commands cd set show where m actual_power displays the input power in watts consumed by all power supplies in the system m ava
51. to XXX XXX XXX XXX gt set SP network commitpending true Set commitpending to true aes In summary you must commit the changes before they can take effect TABLE B 1 ALOM CMT commit Variables and Comparable ILOM Properties ALOM CMT Variable Comparable ILOM Property netsc_commit SP network commitpending ser_commit SP serial external commitpending Creating an ALOM CMT Shell Your server is configured to operate under an ILOM shell by default You can create an ALOM compatibility shell if you prefer to use commands that resemble ALOM CMT commands to administer your server 42 Oracle Integrated Lights Out Manager ILOM 2 0 Supplement for the Sun Netra T5440 Server April 2010 V To Create an ALOM CMT Compatibility Shell 1 Log onto the service processor with the username root When powered on the SP boots to the ILOM login prompt The factory default password is changeme SUNS PxxXXXXxXXXXXXX login root Password Waiting for daemons to initialize Daemons ready Sun TM Integrated Lights Out Manager Version 2 0 0 0 Copyright 2007 Sun Microsystems Inc All rights reserved Use is subject to license terms Warning password is set to factory default 2 Create a user named admin and set the admin account role to Administrator and the CLI mode to alom gt create SP users admin Enter new password Creating user gt set SP users admin role Administ
52. tre responsabilit de prendre toutes les mesures de secours de sauvegarde de redondance et autres mesures n cessaires son utilisation dans des conditions optimales de s curit Oracle Corporation et ses affili s d clinent toute responsabilit quant aux dommages caus s par l utilisation de ce logiciel ou mat riel pour ce type d applications Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses affili s Tout autre nom mentionn peut correspondre des marques appartenant d autres propri taires qu Oracle AMD Opteron le logo AMD et le logo AMD Opteron sont des marques ou des marques co d Advanced Micro Devices Intel et Intel Xeon sont des marques ou des marques d pos es d Intel Corporation Toutes les marques SPARC sont utilis es sous licence et sont des marques ou des marques d pos es de SPARC International Inc UNIX est une marque d pos e conc d e sous licence par X Open Company Ltd Ce logiciel ou mat riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc s des contenus des produits et des services manant de tiers Oracle Corporation et ses affili s d clinent toute responsabilit ou garantie expresse quant aux contenus produits ou services manant de tiers En aucun cas Oracle Corporation et ses affili s ne sauraient tre tenus pour responsables des pertes subies des co ts occasionn s ou des dommages caus s par l acc s des co
53. y type gt set HOST autorunonerror value where value can be as follows m true The system stops booting after an error has been discovered the default m false The system attempts to continue booting after an error has been discovered V To View Host Information Using the Web Interface This procedure describes how to view and configure several kinds of host information Chapter 2 Managing the Host 9 REFRESH LOG OUT Role Administrator root SP Hostname SUNSPO0144F3F8CAF Sun Integrated Lights Out Manager Remote Control Remote Power Control Diagnostics Host Control Boot Mode Settings Keyswitch Host Control View and configure the host control information Auto Run on Error determines whether the host should continue to boot in the event of a non fatal POST error Auto Restart Policy determines what action the Service Processor should take when it discovers the host is hung MAC Address 00 14 4f 3f 8c a6 OBP Version OBP n2 build_100 PROTOTYPE BUILD 2007 05 16 18 19 stacie obp 0 POST Version Sun Fire TM Huron POST 4 x 0 n2 build_100 2007 05 16 19 23 Post Status OS Running Auto Run On Error False ks Auto Restart Policy Reset ILOM provides several ways to view or configure host control features There are six aspects to host control m MAC address OpenBoot version m POST version m POST status m Auto Run On Error a Auto Restart Policy