Contents

1. DE AT pi ICE NNI H Chapter 1 Overview 1 7 TABLE 1 2 LEDs and Their Meanings Figure Callout LED Color Usage Summary State Status 1 ACT Amber Ethernet Activity Off No network activity LED blinks to show data network m uo E Blinking Network activity activity 2 LNK Green Ethernet Link On Link Active at 1 Gbps Amber On Link Active at 100 Mbps NA Off Link Active at 10 Mbps 3 OK Green Module is powered On Module is powered on Off Module is powered off 4 OOS Red Fault or Out of Service On Module fault Off No module fault 5 HOT Blue Hot Swap indicator On Management power SWAP available to the module and the module can safely be extracted Off The module is operational and is unsafe to extract Slow Blinking Delay before module is deactivated Fast Blinking Delay before module is activated 1 8 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 1 5 Part Number Serial Number and MAC Address Labels The Netra CP32x0 ARTM FC serial number part number and media access control MAC address are printed on stickers located on the module For proper identification of the ARTM FC find the Sun Microsystems barcode labels on the module FIGURE 1 3 Netra CP32x0 ARTM FC Identification Labels Sun SIN 1898HSV 0837010004 Product Name ARTM FC 350 9300600487 000000 90 MMOL A000 0000
2. Index 4 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April
3. EMI 2 5 electronic keying e Keying 2 6 3 2 electrostatic discharge ESD 2 2 EMI electromagnetic interference 2 5 empty chassis installing boards 2 5 Emulex IOC3532 controller 4 5 4 6 energy hazards 2 2 environmental specifications and compliance 4 4 ESD precautions 2 5 Ethernet 4 6 Ethernet management port 4 5 event commands 3 3 F features Netra CP32x0 ARTM FC 1 2 fibre channel network access 2 8 SFP connector 4 14 SFP connector pin assignments 4 14 file corruption 2 6 front and rear board installations 2 3 front panel 1 7 FRU device commands 3 3 FRU information 3 5 Index 1 full duplex mode 4 7 G GbE connections 2 8 controllers 4 7 RJ45 connector pin assignments 4 10 4 15 RJ45 copper connector 4 15 SFP connector pin assignments 4 11 SPF connector 4 11 Gigabit Ethernet GbE 1 2 4 7 Gigabit Ethernet Controllers 4 7 H half duplex mode 4 7 Hardware Platform Management HPM 3 2 headers 4 8 host boards compatible 2 4 hot swap 4 5 communication 3 2 insertion 2 6 HPM 1 extension commands 3 4 HS LED 1 8 I I O connectors 4 9 ID 15 3 2 identifying the ARTM 1 9 illustration of Netra CP32x0 ARTM FC 1 4 inlet air temperature 3 2 input output I O 4 4 installing 2 7 Intel 82571EB controllers 4 5 Intelligent Platform Management Interface IPMI 1 2 IPM device global commands 3 3 IPMBL address 3 2 IPMI 2 0 requests supported 3 3 IPMI F
4. 12 Temperature Threshold LM74 1 U36 13 Temperature Threshold LM74 2 U34 TABLE 3 4 Threshold Values for Voltage Sensors Sensor Description Threshold of nominal Upper Non Critical 1 05 Lower Non Critical 0 95 Upper Critical 1 10 Lower Critical 0 90 Upper Non Recoverable 1 15 Lower Non Recoverable 0 85 Normal Max 1 03 Normal Min 0 97 TABLE 3 5 Threshold Values for Temperature Sensors Sensor Temperature Threshold in Celcius Nominal Temperature 30 Normal Max 40 Normal Min 20 High 45 Chapter 3 MMC and IPMI 3 7 3 8 TABLE 3 5 Threshold Values for Temperature Sensors Continued Sensor Temperature Threshold in Celcius Low 10 Upper Critical 55 Lower Critical 0 Upper Non Recoverable 65 Lower Non Recoverable 10 These sensor data records SDRs are available in the Netra CP32x0 ARTM FC and can be accessed by using the Get Device SDR request For sensors 2 13 the SDR record type is 0x01 Full Sensor Record Sensor 1 has an SDR record type of 0x12 Management Controller Device Locator Record Sensors 2 13 generate events Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 CHAPTER 4 Specifications Components and Connectors This chapter contains information on the specifications components and connectors for the Sun Netra CP32x0 ARTM FC This chapter contains the following sect
5. 3 FRU Information 3 5 34 ARTM e Keying 3 6 3 5 Sensor Data Records 3 6 4 Specifications Components and Connectors 4 1 4 1 Specifications 4 2 4 1 1 Physical Dimensions 4 2 4 1 2 Power Requirements 4 2 4 1 3 Electrical Requirements 4 2 4 1 4 Thermal Requirements 4 2 4 1 5 Environmental Specifications and Compliance 4 4 42 Hardware Components 4 4 42 1 Ethernet Management Port 4 5 42 2 SerialPort 4 5 4 23 Module Management Controller 4 5 4 2 4 Hot swap Handle Latch 4 5 4 2 5 FRUPROM 4 6 4 2 6 PCI Express Switch 4 6 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 4 2 7 Fibre Channel 4 6 4 2 8 Ethernet 4 6 4 2 8 1 10BASE T 4 6 4 2 8 2 100BASE TX 4 6 4 2 8 3 1000BASE T 4 7 4 2 9 Two Dual GbE Controllers 4 7 4 2 10 GbESFP Ports 4 7 43 Connectors and Pin Assignments 4 8 4 3 1 I O Connectors 4 9 4 3 1 1 LAN and Serial Management Connectors J35 and J34 4 10 4 3 1 2 GbE SFP Connector J38 4 11 4 3 1 3 PCI Express Cable Connector J40 4 12 4 3 1 4 Fibre Channel SFP Connector J37 4 14 4 3 1 5 GbE RJ 45 Copper Connector J36 A D 4 15 4 3 2 Zone 3 Connectors 4 16 Index Index 1 Contents v vi Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 Figures FIGURE 1 1 FIGURE 1 2 FIGURE 1 3 FIGURE 2 1 FIGURE 2 2 FIGURE 4 1 FIGURE 4 2 FIGURE 4 3 FIGURE 4 4 FIGURE 4 5 FIGURE 4 6 FIGURE 4 7 F
6. 4 3 1 4 Fibre Channel SFP Connector J37 This connector provides two ports for Fibre Channel using optical fiber only FIGURE 4 6 Fibre Channel SFP Connector J37 lele A x LE LT EF Ui TA eee fer 4a 5 DD l EITT R J eH 3e H TABLE 4 9 Fibre Channel SFP Connector Pin Assignments J37 Port 1 Port 2 Pin Signal Name Pin Signal Name 1 GND 1 GND 2 FC1_TXFAULT 2 FC2_TXFAULT 3 FC1_TX_DIS 3 FC2_TX_DIS 4 FC1_SDA 4 FC2_SDA 5 FC1 SCL 5 FC2 SCL 6 FC1_PRESENCE 6 FC2_PRESENCE 7 FC1_RATESEL 7 FC2_RATESEL 8 FC1_LOS 8 FC2_LOS 9 GND 9 GND 10 GND 10 GND 11 GND 11 GND 12 FC1_RX 12 FC2_RX 13 FC1_RX 13 FC2_RX 14 GND 14 GND 15 FC1_VCC_RX 15 FC2_VCC_RX 16 FC1_VCC_TX 16 FC2_VCC_TX 4 14 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 TABLE 4 9 Fibre Channel SFP Connector Pin Assignments J37 Continued Port 1 Port 2 Pin Signal Name Pin Signal Name 17 GND 17 GND 18 FC1_TX 18 FC2_TX 19 FC1_TX 19 FC2_TX 20 GND 20 GND 4 3 1 5 GbE RJ 45 Copper Connector J36 A D All four GbE RJ 45 copper ports are encompassed in this one connector see FI
7. Serial Management Connector Pin Assignment J34 4 11 GbE SFP Connector Pin Assignments J38 4 11 PCI E Cable Connector Pin Assignment J40 4 13 Fibre Channel SFP Connector Pin Assignments J37 4 14 GbE RJ 45 Connector Pin Assignments J36 4 15 TABLE 4 11 Zone 3 P32 Pin Assignments 4 17 TABLE 4 12 Zone 3 P33 Pin Assignment 4 17 TABLE 4 13 Zone 3 P30 Power Management Connector Pin Assignment 4 18 x Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 Preface The Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide provides installation instructions and hardware specifications for the Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module ARTM FC This manual is written for technicians system administrators field applications and service engineers authorized service providers ASPs and users involved in the integration of this module into Netra Advanced Telecommunications Computing Architecture ATCA systems Using UNIX Commands This document might not contain information about basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices Refer to the following for this information m Software documentation that you received with your system m Solaris Operating System documentation which is at http docs sun com xi Typographic C
8. Sun Netra CP32x0 ARTM FC can be installed into an ATCA shelf chassis with a midplane made for front and rear board installations The ARTM must be installed in the slot directly behind the host ATCA node board These back to back slots have common PINs to enable passing of signals via the Zone 3 connector complex Caution Connectors on earlier generation node boards do not mate with connectors on the Sun Netra CP32x0 ARTM FC Use the Sun Netra CP32x0 ARTM FC only with compatible node boards Attempts to install the ARTM with an incompatible node board might damage the node board and or the ARTM Chapter2 Installing and Removing the ARTM FC 2 3 2 1 3 1 2 1 3 2 2 1 4 2 4 Safety Statement The Sun Netra CP32x0 ARTM FC is designed to comply with UL60950 1 and is intended to be used with similarly tested AdvancedTCA products that have user documentation detailing installation of AMC module accessories Maximum Power Requirements Be sure to validate that the chassis and the ARTM slot is cable of providing the ARTM the maximum power requirements of 25W current draw Use a Compatible Host Board The Sun Netra CP32x0 ARTM FC was tested and qualified to operate with the following Sun Netra ATCA host boards TABLE 2 1 Compatible Sun Host Boards ATCA Board Description FW revision Sun Netra 10 GbE Opteron blade Rev 0 16 or greater CP3220 Blade Server Sun Netra Dual socket quad core BIOS rev 1 1 or greater C
9. chapter contains the following sections m Section 2 1 Important Information on page 2 2 m Section 2 2 Before Installing or Removing the ARTM on page 2 5 m Section 2 3 Installing the ARTM FC on page 2 7 m Section 24 Removing the ARTM FC on page 2 11 m Section 2 5 Changing the OOS LED Color on page 2 11 2 1 2 1 2 1 1 gt 2 2 Important Information Before installing the Sun Netra CP32x0 ARTM FC verify the ARTM s part number to ensure that the correct ARTM is being installed into the system For information on identifying the ARTM see Section 1 5 Part Number Serial Number and MAC Address Labels on page 1 9 The following paragraphs provide important information to ensure compatibility and safety of the ARTMs other components and the system Take Antistatic Precautions Caution When a system is plugged in energy hazards are present on the midplane Do not reach into the enclosure Caution Electrostatic discharge ESD can damage electronic components Use an antistatic wrist strap and a conductive foam pad when installing or upgrading any components After removing the component from its protective wrapper or from the system place the component flat on a grounded static free surface and in the case of a board component side up Do not slide the component over any surface If an ESD station is not available you can avoid damage resulting from ESD by w
10. 5 TCK TMS 7 PCIE RX 6 PCIE RX 6 PCIE TX 6 PCIE TX 6 TRST TDI 8 PCIE RX 7 PCIE RX 7 PCIE TX 7 PCIE TX 7 TDO PCIE RST 9 N C N C N C N C GND PCI CFG 10 N C N C N C N C PS1 MMC_EN Chapter 4 Specifications Components and Connectors 4 17 FIGURE 4 9 Power Management Connector P30 for Zone 3 TABLE 4 13 Zone 3 P30 Power Management Connector Pin Assignment Pin Signal Pin Signal Al A2 A3 GND A4 A5 A6 Shelf GND B1 B2 B3 GND B4 B5 B6 VCC_3 3V MP SRC C1 C2 C3 IPML SCL C4 C5 C6 IPMI_SDA D1 D2 D3 VCC_12V D4 D5 D6 VCC_12V El E2 E3 PS1 E4 E5 E6 No Connection 4 18 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 Index Numerics 1000BASE T 4 4 4 7 100BASE TX 4 4 4 6 4 7 10BASE T 4 4 4 6 4 7 6U 4 2 A ACT LED 1 8 Advanced Telecom Computing Architecture ATCA 1 2 Airflow requirements 4 2 AMC modules installation 2 4 antistatic wrist strap 2 2 Application extension commands 3 4 applications terminating 2 6 ATCA shelf chassis 2 3 B backplane connectors for Zone 3 4 16 back to back slots 2 3 Blade Management Controller BMC 3 3 blue LED 2 6 board removal 2 6 C changing the OOS LED color 2 11 compatible node boards 2 3 compliance EMI 2 5 connectors 4 8 D data corruption 2 6 description of connectors 4 9 E electrical requirements 4 2 electromagnetic interference
11. 5 C 2 2 28 C 2 5 40 C B 6 55 C 4 2 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 TABLE 4 2 RTM Pressure Drop Volumetric Volumetric Flow Rate Flow Rate Pressure Drop Pressure Drop CFM m3 min Pa inches of H O 0 0 0000 0 0000 0 0000 1 0 0283 0 0284 0 0001 2 0 0566 0 0974 0 0004 3 0 0850 0 2169 0 0009 4 0 1133 0 3785 0 0015 5 0 1416 0 5817 0 0023 6 0 1699 0 8182 0 0033 7 0 1982 1 0834 0 0044 8 0 2265 1 3872 0 0056 9 0 2549 1 8202 0 0073 10 0 2832 2 0729 0 0083 FIGURE 4 1 RTM Pressure Drop a Pressure Drop Pa 0 5 2 0 05 Volumetric Flow Rate CFM 6 8 4 0 1 0 15 0 2 0 25 Volumetric Flow Rate m min Chapter 4 Specifications Components and Connectors 0 3 Pressure Drop inches in H 0 4 3 4 1 5 Environmental Specifications and Compliance The environmental specifications for the Sun Netra CP32x0 ARTM FC assembly are as follows TABLE 4 3 Environmental Specifications Specification Value Operating Temperature airflow 5 0 CFM 0 C 55 Operating Temperature airflow 2 0 CFM 0 C 23 Storage Temperature 40 85 Operating Shock See PICMG 3 0 specification Regulatory guidelines Operating Vibration See PICMG 3 0 specification Regulatory guidelines RoHS 6 of 6 compliant 4 2 4 4 Hardware Components The S
12. Board on page 2 4 Section 2 2 2 Inspect for Bent PINs or Other Damage on page 2 5 Section 2 2 3 Preserve EMI Compliance on page 2 5 Section 2 2 4 Understand Hot Swap on page 2 6 Chapter 2 Installing and Removing the ARTM FC 2 7 FIGURE 2 1 Installing a Node Board and ARTM FC Into the ATCA Chassis A N N R E R R Figure Legend 1 Netra ATCA node board blade server installed from front 2 ATCA midplane front 3 Netra ARTM FC installed from rear The Sun Netra CP32x0 ARTM FC must be used with a Netra ATCA node board for rear I O access The ARTM FC enables access to Fibre Channel networks and additional GbE connections 2 8 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 gt gt Caution The Sun Netra CP32x0 ARTM FC and the corresponding Sun Netra blade server can be installed while the shelf is powered However start with a power shelf only if you must do so The ARTM FC must be installed before the node board Caution Ensure that no node board is installed in front of the rear midplane slot This precaution is very important if you are installing into a powered midplane To Install an ARTM FC 1 Verify that you have taken the necessary antistatic precautions 2 Facing the back of the system identify an appropriate slot for the ARTM FC ARTM FCs must be installed inline behind the acc
13. CA cards that do not comply with this specification The Netra CP32x0 ARTM FC transitions an ATCA node board s I O signals from the Zone 3 user zone connectors to standard I O interfaces The node board drives the LAN and Serial Management ports as well as the Gigabit Ethernet GbE SFPs using the Zone 3 I O There is a x8 PCI Express PCI E link connected to a switch which drives downstream x4 ports to the Fibre Channel and GbE controllers as well as the PCI E cable connector The Netra CP32x0 ARTM FC maximizes communications I O for GbE networks by providing four fixed 10 100 1000BASE T copper ports and two user configurable SFP ports on a single module The rear I O access enables replacement of the Netra ATCA node board without disconnecting cables Industry standard connectors and pin assignments ensure ease of use and flexible design The Netra CP32x0 ARTM FC permits the creation of high density systems by enabling easy access to I O See FIGURE 1 1 for an illustration of the Netra CP32x0 ARTM FC Features of the Netra CP32x0 ARTM FC include m ATCA RIM form factor per ATCA specifications see Chapter 2 m Intelligent Platform Management Interface IPMI controller with a Module Management Controller MMC Silicon Labs C8051F127 to provide full module management support m Hot swap ability allows module replacement during live operation per the ATCA Specification m PCI E switch compliance with PCI Express 2 0 Base Specific
14. ERA Sun PIN 375 3514 01 rev 00 Chapter 1 Overview 1 9 The barcode labels provide the following information TABLE 1 3 Netra CP32x0 ARTM FC Identification Labels Label Description 1 Top Level Assembly Label Contract manufacturer part format Contract manufacturer serial number 2 Sun Serial Number Label Sample 1898HSV 0547XL1234 where e 1898 vendor code e HSV factory code e 05 year code e 47 week code e XL multiuse code e 1234 sequence number 3 Prototype Label appears only on preproduction ARTMs 4 Sun Product Name and Part Number Label Product Name ARTM FC Sun P N 375 3514 xx rev xx 1 6 Software Support The Netra CP32x0 ARTM FC supports ATCA node boards designed to be compatible with the AdvancedTCA specification and the software supported by those boards Refer to the following documentation for software support information about Sun blade servers that are compatible with this ARTM m Sun Netra CP3220 Blade Server Product Notes 820 1980 m Sun Netra CP3250 Blade Server Product Notes 820 5194 m Sun Netra CP3260 Blade Server Product Notes 820 0455 1 10 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 CHAPTER 2 Installing and Removing the ARTM FC This chapter contains procedures for unpacking installing and removing the Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module ARTM FC This
15. GURE 4 7 They are arranged from bottom to top labeled 1 through 4 These ports are independent of each other TABLE 4 10 lists the basic signal names FIGURE 4 7 GbE RJ 45 Copper Connector J36 I n E r mE gt Sao CII Ete C Og g OET M DUI Te J I ii csi I 5 CO 1 ET e a TABLE 4 10 GbE RJ 45 Connector Pin Assignments J36 Pin Name Description 1 BI DA Bi directional pair A 2 BI DA Bi directional pair A 3 BI DB Bi directional pair B 4 BI DC Bi directional pair C 5 BI DC Bi directional pair C 6 BI DB Bi directional pair B 7 BI DD Bi directional pair D 8 BI DD Bi directional pair D Chapter 4 Specifications Components and Connectors 4 15 Note All four ports have the same pinouts 4 3 2 Zone 3 Connectors The I O connections for rear access are provided by the Netra node board through the Zone 3 connectors The Zone 3 I O connectors are P31 P32 and P33 The Zone 3 connectors are shown in FIGURE 4 8 The pin assignments for P32 and P33 are in TABLE 4 11 and TABLE 4 12 P31 is not used on the Su
16. IGURE 4 8 FIGURE 4 9 Netra CP32x0 ARTM FC 1 4 Netra CP32x0 ARTM FC Front Panel 1 7 Netra CP32x0 ARTM FC Identification Labels 1 9 Installing a Node Board and ARTM FC Into the ATCA Chassis 2 8 Injector Ejector Latch and Locking Screw 2 9 RTM Pressure Drop 4 3 Sun Netra CP32x0 ARTM FC Connectors 4 8 LAN and Serial Management Connectors J35 and J34 4 10 GbE SPF Connector J38 4 11 PCI E Cable Connector J40 4 12 Fibre Channel SFP Connector J37 4 14 GbE RJ 45 Copper Connector J36 4 15 Backplane Connectors for Zone 3 4 16 Power Management Connector P30 for Zone 3 4 18 vii viii Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 Tables TABLE 1 1 TABLE 1 2 TABLE 1 3 TABLE 2 1 TABLE 2 2 TABLE 3 1 TABLE 3 2 TABLE 3 3 TABLE 3 4 TABLE 3 5 TABLE 4 1 TABLE 4 2 TABLE 4 3 TABLE 4 4 TABLE 4 5 TABLE 4 6 TABLE 4 7 TABLE 4 8 TABLE 4 9 TABLE 4 10 O Ports on ARTM FC Faceplate 1 5 LEDs and Their Meanings 1 8 Netra CP32x0 ARTM FC Identification Labels 1 10 Compatible Sun Host Boards 2 4 Blue LED Indications 2 6 IPMI Commands 3 3 Port and Link Information 3 6 Netra CP32x0 ARTM FC Sensors 3 6 Threshold Values for Voltage Sensors 3 7 Threshold Values for Temperature Sensors 3 7 Airflow Requirements 4 2 RTM Pressure Drop 4 3 Environmental Specifications 4 4 Description of Connectors 4 9 LAN Management Connector Pin Assignments J35 4 10
17. LIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Cette distribution peut comprendre des composants d velopp s par des tierces parties Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Netra Sun Ray le logo Netra et le logo Solaris sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc ou ses filiales aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc see above L utilisation de pieces detachees ou d unites centrales de remplacement est limitee aux reparations ou a l echange standard d unites centrales pour les produits exportes conformement a la legislation americaine en matiere d exportation S
18. MMC provides a variety of functions including the following Supports hot swap operation as defined in the AMC 0 specification Supports e Keying as described in the AMC 0 specification Monitors inlet air temperature Monitors onboard voltage monitoring Stores FRU information sensor records and e Keying data using an external EEPROM Complies with the Hardware Platform Management HPM IPMI Controller Firmware Upgrade specification Supports firmware rollback using an external flash Controls onboard HOT SWAP OOS and OK LEDs Controls onboard power sequencing and device resets Optional LC control of GbE SFPs The MMC implementation conforms to the ARTM port commands specified in the AdvancedTCA specification An ATCA board communicates to the ARTM using site ID 15 and thus an IPMB L address of 0x8E The IPMB L is monitored by an PC buffer that prevents bus lockups and conflicts at ARTM insertion 3 2 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 3 2 IPMI Commands The MMC communicates with the blade management controller BMC via the local IPMB The Netra CP32x0 ARTM FC supports the following IPMI 2 0 commands per the AMC 0 specification TABLE 3 1 IPMI Commands Request CMD IPM Device Global Commands App NetFn 0x06 Get Device ID 0x01 Get Self Test Results 0x04 Event Commands Sensor Event NetFn 0x04 Set Event Receiver 0x00 Get Event Receiver 0
19. ND 11 GND 12 SERDES GIGE1 RX 12 SERDES GIGE2 RX 13 SERDES_GIGE1_RX 13 SERDES_GIGE2_RX 14 GND 14 GND 15 SERDES_GIGE1_VCC_RX 15 SERDES_GIGE2_VCC_RX 16 SERDES_GIGE1_VCC_TX 16 SERDES_GIGE2_VCC_TX 17 GND 17 GND 18 SERDES_GIGE1_TX 18 SERDES_GIGE2_TX 19 SERDES_GIGE1_TX 19 SERDES_GIGE2_TX 20 GND 20 GND 4 3 1 3 PCI Express Cable Connector J40 This connector provides support for one external x4 PCI E cable connection FIGURE 4 5 PCI E Cable Connector J40 3 TTO c T B Z m7 im T 4 FL gi III TINI LT TU CN g J al el eee l5 TUA er 4 12 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 TABLE 4 8 PCI E Cable Connector Pin Assignment J40 Pin Pin Row A Signal Name Row B Signal Name 1 GND 1 GND 2 TX 0 2 RX 0 3 TX 0 3 RX 0 4 GND 4 GND 5 TX 1 5 RX 1 6 TX 1 6 RX 1 7 GND 7 GND 8 TX 2 8 RX 2 9 TX 2 9 RX 2 10 GND 10 GND 11 TX 3 11 RX 3 12 TX 3 12 RX 3 13 GND 13 GND 14 CLK 14 3 3V 15 CLK 15 3 3V 16 GND 16 GND 17 SB_RTN 17 GND 18 CPRSNT 18 No Connection 19 CPWRON 19 CPERST Chapter 4 Specifications Components and Connectors 4 13
20. Online Upgrades Usage this Sun Netra CP32x0 Quad GbE 820 3148 PDF Online document Dual Fibre Channel Advanced Rear HTML Online Transition Module User s Guide Safety and Netra CP32x0 Advanced Rear 820 3506 PDF Online Compliance Transition Module Safety and HTML Online Compliance Manual Safety Important Safety Information for 816 7190 Printed Shipping kit Sun Hardware Systems The following table lists the documentation that is related to this product Application Title Part Number Format Location Latest Sun Netra CP3220 Blade Server 820 0455 PDF Online at information Product Notes http docs sun com app docs prod cp3220 brd hic Latest Netra CP3250 Blade Server Product 820 5194 PDF Online information Notes http docs sun com app docs prod cp3250 brd hic Latest Sun Netra CP3260 Blade Server 820 0455 PDF Online at information Product Notes http docs sun com app docs prod cp3260 brd hic Preface xiii Documentation Support and Training Sun Function URL Documentation http www sun com documentation Support http www sun com support Training http www sun com training Third Party Web Sites Sun is not responsible for the availability of third party web sites mentioned in this document Sun does not endorse and is not responsible or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actu
21. P3250 Blade Intel based ATCA blade Server Sun Netra UltraSPARC T2 ATCA blade OpenBoot 4 27 8 or greater CP3260 Blade Server The Sun Netra CP32x0 ARTM FC is designed to operate with similarly tested AdvancedTCA products Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 2 2 22 41 222 2 2 3 Before Installing or Removing the ARTM ARTMs can be damaged when improperly handled Read and follow the guidelines in this section to protect your equipment Observe ESD Precautions Installation persons are urged to use an antistatic wrist strap and a conductive foam pad when installing or upgrading a system See Section 2 1 1 Take Antistatic Precautions on page 2 2 Inspect for Bent PINs or Other Damage Bent PINs or loose components can cause damage to the ARTM host board the backplane or other system components Carefully inspect your ARTM and the backplane for both PIN and component integrity before installation Our manufacturers take significant steps to ensure there are no bent PINs on the backplane or connector damage to the products prior to leaving our factory Bent PINs caused by improper installation or by products with damaged connectors could void the warranty for the backplane boards and modules If a system contains one or more crushed PINs power off the system and contact your local sales representative to schedule delivery of a replacement c
22. RU PROM 4 6 L LAN 4 10 LEDs ACT 1 8 blue 2 6 green 1 8 HS 1 8 LNK 1 8 OK 1 8 OOS 1 8 software control 2 6 LNK LED 1 8 M media access control MAC 1 9 midplane 2 3 Module Management Controller MMC 4 5 N node boards compatible 2 3 O OEM Extension Commands 3 4 OK LED 1 8 OOS LEDs 1 8 Out of service OOS 2 11 P packing list and material 2 3 PCI E cable connector 4 12 PCI E cable connector pin assignment 4 13 PCI Express PCI E 4 5 physical dimensions 4 2 PINs bent or damaged 2 5 common 2 3 port commands compliance 3 2 ports 1 5 power requirements 2 4 4 2 powering down 2 6 R rear I O access 2 8 removing the ARTM 2 11 RIM pressure drop 4 3 S sensor device commands 3 3 serial management 4 10 serial port 4 5 Index 2 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April shelf manager 2 6 shut down 2 6 signals 2 3 slot usage 2 6 slot compatible host 2 3 software support information 1 10 switches 4 8 switches and headers factory use only 4 9 T terminating applications 2 6 thermal requirements 4 2 threshold values temperature sensors 3 7 voltage sensors 3 7 Transmission Control Protocol TCP 1 3 U UL60950 1 compliance 2 4 V voltage monitoring 3 2 Z Zone 3 backplane connectors 4 16 connector complex 2 3 connectors 4 16 P32 pin assignments 4 17 Index 3
23. S RV JUN microsystems Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide Sun Microsystems Inc www sun com Part No 820 3148 10 April 2009 Revision 01 Submit comments about this document at http www sun com hwdocs feedback Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved This distribution may include materials developed by third parties Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Netra Sun Ray the Netra logo and the Solaris logo are trademarks or registered trademarks of Sun Microsystems Inc and its subsidiaries in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsystems Inc Use of any spare or replacement CPUs is limited to repair or one for one D procement of CPUs in products exported in compliance with U S export laws Use of CPUs as product upgrades unless authorized by the U S Government is strictly prohibited DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMP
24. al or alleged damage or loss caused by or in connection with the use of or reliance on any such content g00ds or services that are available on or through such sites or resources Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide part number 820 3148 10 xiv Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 CHAPTER 1 Overview This chapter provides an overview of the Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module ARTM FC This chapter contains the following topics Section 1 1 Features on page 1 2 Section 1 2 Standards Compliance on page 1 5 Section 1 3 I O Interfaces on page 1 5 Section 1 4 LEDs on page 1 6 Section 1 5 Part Number Serial Number and MAC Address Labels on page 1 9 Section 1 6 Software Support on page 1 10 1 1 1 2 Features The Netra CP32x0 ARTM FC is a fully compatible carrier grade Advanced Telecom Computing Architecture ATCA RTM for ATCA node boards designed to be compatible with the AdvancedRTM specification and is not compatible with AT
25. ame pinouts 4 10 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 4 3 1 2 TABLE 4 6 Serial Management Connector Pin Assignment J34 Pin Signal Name Pin Signal Name 1 RIS 2 DTR 3 TXD 4 GND 5 DCD 6 RXD 7 DSR 8 CTS GbE SFP Connector J38 This connector provides two ports supporting modules for either copper cable or optical fiber The ports can be either both copper or both optical or one can be copper and the other optical The ports are independent of each other FIGURE 4 4 GbE SPF Connector J38 TE 1111111 2i W LUV Oo ba TABLE 4 7 GbE SFP Connector Pin Assignments J38 Port 5 Port 6 Pin Signal Name Pin Signal Name 1 GND 1 GND 2 SERDES_GIGE1_TXFAULT_SFP 2 SERDES_GIGE2_TXFAULT_SFP 3 SERDES_GIGE1_TX_DIS 3 SERDES GIGE2 TX DIS 4 SERDES GIGE1 SDA 4 SERDES GIGE2 SDA 5 SERDES GIGE1 SCL 5 SERDES GIGE2 SCL Chapter 4 Specifications Components and Connectors 4 11 TABLE 4 7 GbE SFP Connector Pin Assignments J38 Continued Port 5 Port 6 Pin Signal Name Pin Signal Name 6 SERDES_GIGE1_PRESENCE 6 SERDES_GIGE2_PRESENCE 7 SERDES_GIGE1_RATESEL 7 SERDES_GIGE2_RATESEL 8 SERDES_GIGE1_LOS 8 SERDES_GIGE2_LOS 9 GND 9 GND 10 GND 10 GND 11 G
26. ation Revision 0 9 m PCI E x8 bus interface to node card m LAN management port RJ 45 connector m RS232 serial management port RJ 45 connector m Auto negotiations and automatic MDI MDIX switchover to each fixed GbE port Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 Transmission Control Protocol TCP segmented checksum off loading Compliance with IEEE 802 3a for 10 100 1000BASE T Four fixed GbE ports copper RJ 45 connectors Two user configurable GbE ports SFP modules Two Fibre Channel ports SFP modules IEEE 802 1Q VLAN support up to 4094 VLAN tags 25 W Max power Designed for NEBS level 3 compliance Chapter 1 Overview 1 3 FIGURE 1 1 Netra CP32x0 ARTM FC S PE o o o o o o Hl o o o H o on o E o o o E o o o B THEY ut uj 1 4 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 1 2 Standards Compliance The Netra CP32x0 ARTM FC is compliant with the following specifications m PICMG 3 1 from the ATCA Specification m PCI Express 2 0 Base Specification Revision 0 9 m PCI E External Cabling Specification Rev 1 0 1 3 I O Interfaces The Netra CP32x0 ARTM FC installs into the
27. auf autorisation par les autorites des Etats Unis l utilisation d unites centrales pour proceder a des mises a jour de produits est rigoureusement interdite LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PARLA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON 5 cx SA Adobe PostScript Contents Preface xi Overview 1 1 1 1 1 2 1 3 1 4 1 5 1 6 Features 1 2 Standards Compliance 1 5 I O Interfaces 1 5 LEDs 1 6 Part Number Serial Number and MAC Address Labels 1 9 Software Support 1 10 Installing and Removing the ARTM FC 2 1 2 1 2 2 Important Information 2 2 2 1 1 Take Antistatic Precautions 2 2 2 1 2 Unpack the Equipment Carefully 2 3 2 1 3 Use a Compatible Chassis and Slot 2 3 2 1 3 1 Safety Statement 2 4 2 1 3 2 Maximum Power Requirements 2 4 2 14 Use a Compatible Host Board 2 4 Before Installing or Removing the ARTM 2 5 2 2 1 Observe ESD Precautions 2 5 iv 2 22 Inspect for Bent PINs or Other Damage 2 5 2 2 3 Preserve EMI Compliance 2 5 2 2 4 Understand Hot Swap 2 6 2 25 Verify Slot Usage 2 6 23 Installing the ARTM FC 2 7 24 Removing the ARTM FC 2 11 25 Changing the OOS LED Color 2 11 3 MMCandIPMI 3 1 3 1 MMC and IPMI Functions 3 2 3 2 IPMI Commands 3 3 3
28. companion node board type clia deactivate board 1 2 Loosen the locking screws on the ARTM FC 3 Pull the ARTM FC out of the card slot 4 If the card slot is to remain empty install a filler panel in the slot 5 Reactivate the node board if necessary 2 5 Changing the OOS LED Color The color of the Out of service OOS LED can be set to red or amber by moving jumper E21 to the appropriate position Setting the jumper to the 1 2 position makes the OOS LED appear red default setting Setting the jumper to the 2 3 position makes the OOS LED appear amber Chapter 2 Installing and Removing the ARTM FC 2 11 2 12 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 CHAPTER 3 MMC and IPMI This chapter describes the Module Management Controller and Intelligent Platform Management Interface This chapter contains the following sections Section 3 1 MMC and IPMI Functions on page 3 2 Section 3 2 IPMI Commands on page 3 3 Section 3 3 FRU Information on page 3 5 Section 3 4 ARTM e Keying on page 3 6 Section 3 5 Sensor Data Records on page 3 6 3 1 3 1 MMC and IPMI Functions The Netra CP32x0 ARTM FC module includes a Modular Management Controller MMC that communicates with the ATCA blade using the Intelligent Platform Management Interface IPMI The MMC software complies with PICMG AMC 0 RC1 1 The
29. control and indicates the following TABLE 2 2 Blue LED Indications Status Description Off Module has been properly recognized Lit Steady Module can be safely removed Blinking Module state is indeterminate and the module should not be removed Hot swap compliant components may be installed while the system is powered on If a module is not hot swap compliant remove power to the slot or system before installing the component Verify Slot Usage Prevent possible damage to components by verifying the proper slot usage for your configuration See Section 2 1 3 Use a Compatible Chassis and Slot on page 2 3 In most cases electronic keying e Keying will prevent a module to power on in an incompatible slot However as an extra precaution you should be familiar with the slot purpose Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 2 9 Installing the ARTM FC This section describes the procedure for installing the ARTM FC in a chassis See FIGURE 2 1 for an example of installing a node board and ARTM FC into a chassis Before you install your ARTM FC read all cautions warnings and instructions presented in the following sections Section 2 1 1 Take Antistatic Precautions on page 2 2 Section 2 1 2 Unpack the Equipment Carefully on page 2 3 Section 2 1 3 Use a Compatible Chassis and Slot on page 2 3 Section 2 1 4 Use a Compatible Host
30. e ARTM FC via the Zone 3 connectors Each of these devices is connected by a x4 port to the PCI Express Switch Fibre Channel The Sun Netra CP32x0 ARTM FC supports two Fibre Channel ports provided by the onboard Emulex IOC3532 controller These ports connect to SFP modules The controller supports Fibre Channel link speeds of 1 2 and 4 Gbps These rates are software selectable but may be limited by the capability of the module installed Firmware for the Fibre Channel controller including x86 and SPARC boot BIOS is included and can be configured using Emulex utilities The boot BIOS settings can be accessed during the boot sequence Ethernet 10BASE T A network based on the 10BASE T standard uses unshielded twisted pair cables providing an economical solution to the networking by allowing the use of existing telephone wiring and connectors The RJ 45 connector is used with the 10BASE T standard 10BASE T has a maximum length of 100 meters 100BASE TX The Sun Netra CP32x0 ARTM FC also supports the 100BASE TX Ethernet A network based on a 100BASE TX standard uses unshielded twisted pair cables and an RJ 45 connector 100BASE TX has a maximum length of 100 meters Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 4 2 8 3 429 4 2 10 1000BASE T The Sun Netra CP32x0 ARTM FC supports GbE offering speeds of 1000 Mbps It is fully compatible with existing Ethernet as i
31. earing an antistatic wrist strap available at electronics stores that is attached to an active electrical ground Note that a system chassis might not be grounded if it is unplugged Caution Dangerous voltages capable of causing death are present in this equipment Use extreme caution when handling testing and adjusting equipment Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 2 1 2 241 9 Unpack the Equipment Carefully If the shipping carton is damaged upon receipt request that the carrier s agent be present during the unpacking and inspection of the equipment Caution Sun Microsystems has designed special packing material to protect the component during shipping It is critical that you save the packing material Shipping the component without the original packing material might void the warranty Replacement packing material can be purchased from Sun Microsystems 1 Unpack the equipment from the shipping carton 2 Refer to the packing list and verify that all items are present 3 Save the packing material for storing and reshipping of equipment 4 Avoid touching areas of integrated circuitry Static discharge can damage circuits 5 After removing the product from the packaging check for any obvious physical damage 6 Disconnect the chassis from the main power supply before you install the ARTM Use a Compatible Chassis and Slot The
32. hassis assembly Caution When first installing boards in an empty chassis or onto a carrier card start at the left of the card cage and work to the right When inserting or removing a board in a slot adjacent to other boards use extra caution to avoid damage to the PINs and components located on the primary or secondary sides of the boards Preserve EMI Compliance To preserve compliance with applicable standards and regulations for electromagnetic interference EMI during operation all front and rear openings on the chassis or board faceplates must be filled with an appropriate card or covered with a filler panel If the EMI barrier is open devices might cause or be susceptible to excessive interference Chapter 2 Installing and Removing the ARTM FC 2 5 2 24 22 5 2 6 Understand Hot Swap Your ARTM FC is electrically designed for hot swap insertion within a fully powered chassis However hot swap removal is not supported Caution Powering down or removing a board before the operating system or other software running on the board has been properly shut down can cause corruption of data or file systems Prior to board removal terminate applications or operating systems running on the board When this task is complete use the shelf manager to manually shut down activate deactivate the ATCA board which in turn shuts down the ARTM FC There is a blue LED on the rear faceplate This LED is under software
33. ions m Section 4 1 Specifications on page 4 2 m Section 4 2 Hardware Components on page 4 4 m Section 4 3 Connectors and Pin Assignments on page 4 8 4 1 4 1 4 1 1 4 1 2 4 1 3 4 1 4 TABLE 4 1 Specifications This section provides mechanical electrical environmental and other relevant specifications for the Sun Netra CP32x0 ARTM FC Physical Dimensions The Sun Netra CP32x0 ARTM FC is a 6U 322 25 mm height board with 81 mm in depth for standard applications It complies with IEEE 1101 11 mechanical standards as required by the PICMG 2 0 Revision 3 0 specification The Sun Netra CP32x0 ARTM FC is keyed to conform to the PICMG 2 10 Keying of ATCA Boards and Backplane specification Power Requirements The power consumption of the ARTM FC card is limited to 25 W maximum The 3 3 V management power is limited to 150 mA and the current limit set point for the 12 V payload power is 2 5 A Electrical Requirements The Sun Netra CP32x0 ARTM FC is powered through the Netra ATCA node board The node board provides the following voltages 3 3 V and 12 V Thermal Requirements TABLE 4 1 shows the Sun Netra CP32x0 ARTM FC airflow requirements TABLE 4 2 and FIGURE 4 1 show the worst case pressure drop as a function of air flow rate Airflow Requirements Watts m3 min CFM Power Level 25 25 C 0 062 28 C 0 071 40 C 0 102 55 C 0 142 2
34. k Type Extension ARTM PIN Groups 0 0 AMC 2 Ethernet 1000BASE BX Ethernet Link P32 A8 B8 C8 D8 1 1 AMC 2 Ethernet 1000BASE BX Ethernet Link P32 A9 B9 C9 D9 2 30 AMC 2 Ethernet 1000BASE BX Ethernet Link P32 A10 B10 C10 D10 4 2 AMC 1 PCI Express Genl capable P33 Al B1 C1 D1 4 3 AMC 1 PCI Express Genl capable P33 A2 B2 C2 D2 4 4 AMC 1 PCI Express Genl capable P33 A3 B3 C3 D3 4 5 AMC 1 PCI Express Genl capable P33 A4 B4 C4 D4 3 6 AMC 1 PCI Express Gen1 capable P33 A5 B5 C5 D5 3 7 AMC 1 PCI Express Gen1 capable P33 A6 B6 C6 D6 3 8 AMC 1 PCI Express Genl capable P33 A7 B7 C7 D7 3 9 AMC 1 PCI Express Genl capable P33 A8 B8 C8 D8 3 5 Sensor Data Records The following sensors are supported by the Netra CP32x0 ARTM FC Their states can be read using the Get Sensor Reading request TABLE 3 3 Netra CP32x0 ARTM FC Sensors Sensor Number Signal Type Sensor Type Signal Monitored 1 Reserved 2 Event Discrete Hot swap switch 3 Voltage Threshold 12 VDC 4 Voltage Threshold 3 3 VDC Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 TABLE 3 3 Netra CP32x0 ARTM FC Sensors Continued Sensor Number Signal Type Sensor Type Signal Monitored 5 Voltage Threshold 1 8 VDC 6 Voltage Threshold 1 5 VDC 7 Voltage Threshold 1 2 VDC 8 Voltage Threshold 1 0 VDC 1 9 Voltage Threshold 1 0 VDC 2 10 Reserved 11 Temperature Threshold 8051 Internal Temp
35. n Netra CP32x0 ARTM FC P30 Power Management connector is also part of Zone 3 See FIGURE 4 9 and TABLE 4 13 for the illustration and pin assignments FIGURE 4 8 Backplane Connectors for Zone 3 4 16 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 TABLE 4 11 Zone 3 P32 Pin Assignments Pin Row A Signal Row B Signal Row C Signal Row D Signal Row E Signal Row F Signal 1 N C N C N C N C N C N C 2 N C N C N C N C RS232_RTS RS232_DTR 3 N C N C N C N C RS232_TXD RS232_RXD 4 N C N C N C N C RS232_DSR RS232_CTS 5 N C N C N C N C N C N C 6 MGMT LAN A MGMT LAN A MGMT LAN CTV MGMT LAN ACTIV MGMT LAN B MGMT LAN B 7 MGMT LAN C MGMT LAN C MGMT LAN ACT MGMT LAN LINK MGMT LAN D MGMT LAN D 8 GIGE1_RX GIGE1_RX GIGE1_TX GIGE1_TX N C N C 9 GIGE2_RX GIGE2_RX GIGE2_TX GIGE2_TX GIGE4_RX GIGE4_RX 10 GIGE3_RX GIGE3_RX GIGE3_TX GIGE3_TX GIGE4_TX GIGE4_TX Note N C indicates No Connection TABLE 4 12 Zone 3 P33 Pin Assignment Pin Row A Signal Row B Signal Row C Signal Row D Signal Row E Signal Row F Signal 1 PCIE_RX 0 PCIE RX 0 PCIE_TX 0 PCIE TX 0 PCIE CLK PCIE CLR 2 PCIE RX 1 PCIE RX 1 PCIE TX 1 PCIE TX 1 N C N C 3 PCIE RX 2 PCIE RX 2 PCIE TX 2 PCIE TX 2 N C N C 4 PCIE RX 3 PCIE RX 3 PCIE TX 3 PCIE TX 3 N C N C 5 PCIE_RX 4 PCIE_RX 4 PCIE_TX 4 PCIE_TX 4 N C N C 6 PCIE RX 5 PCIE RX 5 PCIE_TX 5 PCIE TX
36. nd Pin Assignments FIGURE 4 2 is an illustration of the Sun Netra CP32x0 ARTM FC connectors switches and headers FIGURE 4 2 Sun Netra CP32x0 ARTM FC Connectors J42 P30 P31 Zone 3 Connectors p32 P33 Serial Management RJ 45 Connector LAN Management RJ 45 Connector S2 Settings for MMC s JTAG S2 Positions 1 4 Off Open S2 Positions 5 8 On Closed gt cj cj cj cj cj GbE SFP Connector 2 ports PCI E Cable Connector Fibre Channel SFP Connector 2 ports Four GbE RJ 45 Connector 4 ports Note All switches and headers on the Netra CP32x0 ARTM FC are factory use only Settings should not be changed and should remain at the default settings 4 8 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 4 3 1 Note All switches and headers on the Sun Netra CP32x0 ARTM FC are factory use only TABLE 4 4 Description of Connectors Connector Description J36 Local MDI GbE RJ 45 Connector contains four ports J40 External PCI E Cable Connector J34 RS232 Serial Management Port RJ 45 Connector J35 LAN Management Port Connector J38 GbE SFP Connector contains 2 ports J37 Fibre Channel SFP Connector contains 2 ports P31 P32 P33 P30 J42 J43 Backplane Connectors for Zone 3 Power Management Connector Guide Modules for proper keying and alignment to the appropriate n
37. ode board I O Connectors The Sun Netra CP32x0 ARTM FC provides the following I O connectors m One RJ 45 connector for LAN Management m One RJ 45 connector for Serial Management m One GbE SFP connector contains two ports m One GbE RJ 45 connector contains four individual GbE ports m One external PCI E connector m One Fibre Channel SFP connector contains two ports Chapter 4 Specifications Components and Connectors 4 9 4 3 1 1 LAN and Serial Management Connectors J35 and J34 FIGURE 4 3 illustrates the connectors for the LAN and Serial Management TABLE 4 5 shows the pin assignments for the LAN connector and TABLE 4 6 shows the pin assignments for the serial connector FIGURE 4 3 LAN and Serial Management Connectors J35 and J34 ds T n 1 j Laat DI WLAV Do gt 319d dj E DE pro soo TABLE 4 5 LAN Management Connector Pin Assignments J35 Pin Name Description 1 BI DA Bi directional pair A 2 BI DA Bi directional pair A 3 BI DB Bi directional pair B 4 BI DC Bi directional pair C 5 BI DC Bi directional pair C 6 BI DB Bi directional pair B 7 BI_DD Bi directional pair D 8 BI_DD Bi directional pair D Note All four ports have the s
38. ompanying node board If the accompanying node board is to be installed in slot 3 its ARTM FC must be installed at the back of the system in slot 3 3 Remove the slot filler panel from the selected node board slot if necessary 4 Prepare the module by loosening the locking screws and opening the injector ejector latch at the top of the module FIGURE 2 2 Injector Ejector Latch and Locking Screw Locking Screw Injector Ejector Latch 5 Carefully align the edges of the module with the guides in the appropriate slot It might be helpful to look into the enclosure to verify correct alignment of the rails in the guides Chapter 2 Installing and Removing the ARTM FC 2 9 2 10 6 Taking care to keep the module aligned in the guides slide the module in until the injector ejector mechanism engages the retention bars 7 Simultaneously push in the module and rotate the injector ejector mechanism inward to its closed position to seat the midplane connectors 8 Tighten the module retention screws to ensure that the module is secured into the shelf 9 Install the node board into the front of the shelf FIGURE 2 1 and push the board toward the midplane Ensure that it is seated properly and that the connectors make good contact with the ARTM FC For further details on installation of the board refer to the appropriate user documentation for the board 10 Install the supported peripheral at the ARTM FC s connector por
39. onventions Typeface Meaning Examples AaBbCc123 The names of commands files and directories on screen computer output AaBbCc123 What you type when contrasted with on screen computer output AaBbCc123 Book titles new words or terms words to be emphasized Replace command line variables with real names or values Edit your login file Use 1s a to list all files You have mail su Password Read Chapter 6 in the User s Guide These are called class options You must be superuser to do this To delete a file type rm filename Note Characters display differently depending on browser settings If characters do not display correctly change the character encoding in your browser to Unicode UTF 8 Related Documentation The following table lists the documentation for this product Except for the Important Safety Information for Sun Hardware Systems all the documents listed are available online at xii Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 http docs sun com app docs prod cp32x0 4gbefc l en hic Application Title Part Number Format Location Getting Sun Netra CP32x0 Quad GbE 820 3149 Printed Shipping kit Started Dual Fibre Channel Advanced Rear PDF Online Transition Module Getting Started HTML Online Guide Latest Netra CP32x0 Advanced Rear 820 3261 PDF Online information Transition Module Product Notes HTML
40. ransition Module User s Guide April 2009 DD FRU Information The Netra CP32x0 ARTM FC contains FRU information in non volatile memory as definedin AMC 0 This includes general information about the product model number manufacturer s name etc and information necessary for proper e Keying with the carrier The parsed FRU information is as follows Common Header Board Info Area Version 1 Language Code Mfg Date Time Board Manufacturer Board Product Name Board Serial Number Board Part Number FRU Programmer File ID Product Info Area Version 1 Language Code Manufacturer Name Product Name Product Part Model Product Version Product Serial Number Asset Tag FRU Programmer File ID Multi Record Area Oc Format Version 1 0 t 29 15 30 00 2007 6220290 minutes since 1996 GE FANUC RTM2 000000 1234567890 350 9300800487 000000 04 14 08 0 GE FANUC ARTM FC 375 3514 01 50 1898HSV YYWW01SSSS 04 04 14 08 Module Current Requirements Record ID 0x16 Version 0 AMC Point to Point Connectivity Record ID 0x19 Version 0 Record Format Version 0x00 Note The FRU information shown above serves as an example and could change without notice Chapter 3 MMC and IPMI 3 5 3 4 ARTM e Keying The Netra CP32x0 ARTM FC contains custom Common Option and Extended port connections are as follows TABLE 3 2 Port and Link Information Channel Port Link Type Lin
41. rear of the ATCA enclosure opposite an ATCA node board designed for compatibility with the AdvancedRTM specification The ARTM FC connects to the node board s Zone 3 rear connectors directly The ARTM FC supports four fixed GbE ports copper RJ 45 two Fibre Channel ports SFP one x4 PCI E port two modular GbE ports SFP one LAN management port RJ 45 and one serial management port RJ 45 on the front panel TABLE 1 1 I O Ports on ARTM FC Faceplate RTM Zone 3 Function RTM Faceplate PCI E x8 2 5 GHz lt gt Port 1 1GbE RJ 45 lt gt Port 2 1GbE RJ 45 lt gt Port 3 1GbE RJ 45 lt gt Port 4 1GbE RJ 45 gt Port 1 FC SFP gt Port 2 FC SFP 1GbE SERDES Port 5 1GbE SFP Port 6 1GbE SFP Management port 1 Port 7 1GbE RJ 45 Management port 2 Port 8 RS232 RJ 45 IPMI to MMC device on ARTM NA Power NA Chapter 1 Overview 1 5 1 4 LEDs LEDs are located on the front panel of the Netra CP32x0 ARTM FC See FIGURE 1 2 1 6 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 FIGURE 1 2 Netra CP32x0 ARTM FC Front Panel ATIA Sum Ld ee r 8 c C C LJ UILI LIR m 111 e IE 11 TUM
42. s The other two GbE ports are supported by the Ethernet controller on the host board using a SERDES protocol The RS 232 serial port and the LAN Management port are used for managing the host ATCA blade Ethernet Management Port The Sun Netra CP32x0 ARTM FC provides one 10 100 1000BASE T Ethernet management port as an RJ 45 connector equipped with LEDs Serial Port The Sun Netra CP32x0 ARTM FC provides one asynchronous RJ 45 serial port as an RJ 45 connector The serial port may be redirected to and from the front node board when using an ARTM FC compatible node board For more information on using both the front and rear serial ports refer to the appropriate node board documentation Module Management Controller The onboard MMC provides IPMI management communication between the ARTM FC and the node board and local monitoring of temperature and voltage The MMC also controls the Hot swap function Hot swap Handle Latch The Hot swap latch allows for easy module replacement during live operation Chapter 4 Specifications Components and Connectors 4 5 4 2 5 4 2 6 4 2 7 4 2 8 4 2 8 1 4 2 8 2 4 6 FRU PROM The Sun Netra CP32x0 ARTM FC contains an IPMI FRU PROM compatible with the ATCA specification PCI Express Switch The PCI Express Switch is used to aggregate the two Ethernet Controllers Fibre Channel Controller and external PCI E cable connector into a x8 PCI E port connected to the rear I O of th
43. t uses the same CSMA CD and MAC protocols 1000BASE T has a maximum length of 3000 meters using Single mode fiber optic cables Two Dual GbE Controllers Each dual GbE controller supports two fixed GbE ports via copper RJ 45 connectors The controllers support 10BASE T 100BASE TX and 1000BASE T operational modes which comply with IEEE 802 3 802 3u 802 3ab specifications and TCP segmentation and checksum offloading reducing the host CPU utilization Each port features auto negotiations and automatic MDI MDIX switchover on RJ 45 ports to enable greater compatibility with existing devices and infrastructures Both full duplex and half duplex modes are supported in 10BASE T and 100BASE TX modes The 1000BASE T mode supports only full duplex operations Each dual GbE controller supports boot over LAN using a PXE boot ROM which can be configured during the boot sequence This firmware appears to the protocol stack as ordinary MAC layer interfaces and is ready to use without modifications The protocol stack simply interfaces to a MAC layer driver which communicates to the onboard GbE MACs through the PCI Express bus GbE SFP Ports The Sun Netra CP32x0 ARTM FC supports two GbE ports connected directly to the Ethernet controller on the host board using a SERDES protocol These ports connect to SFP modules The module type fiber or copper is user configurable Chapter 4 Specifications Components and Connectors 4 7 4 3 Connectors a
44. ts as required Use shielded cables for the ports on the ARTM FC The shield should be grounded at both ends For further details on installation of the board refer to the appropriate user documentation for the board 11 Power on the system if necessary Refer to your system manual for instructions on correctly powering on the system Note If you are installing a Sun Netra CP32x0 ARTM FC paired with a Sun Netra blade server into a system with a 10 GbE switch you must perform a one time configuration on the Sun Netra blade server to assure the blade server and ARTM FC operate at the correct speed for your switch For information on configuring your board see the applicable Sun Netra blade server documentation which is listed in the Preface Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 2 4 Removing the ARTM FC Caution Payload Power to the Sun Netra CP32x0 ARTM FC must be off before the module can be safely removed To Remove the ARTM FC 1 Deactivate the ARTM FC from the shelf manager or manually deactivate the ARTM FC by unlatching the top latch and waiting for the blue LED to light steady For example to deactivate just the ARTM FC in slot 1 log into the shelf manager and type clia deactivate 9a 3 where 9a is the hex address for slot 1 and 3 is the ARTM FC in slot 1 Alternatively to deactivate both the ARTM FC and its
45. un Netra CP32x0 ARTM FC maximizes communications input output I O for GbE networks by providing four fixed 10BASE T 100BASE TX or 1000BASE T ports and two modular SFP ports controlled by a device on the ATCA blade on a single module The Sun Netra CP32x0 ARTM FC contains the following components and connectors See FIGURE 4 2 for a block diagram and Section 4 3 Connectors and Pin Assignments on page 4 8 m Two Dual GbE controllers m 24 lane PCI Express switch m IPMI Controller for module management m Four fixed GbE ports copper RJ 45 connectors m Two modular GbE ports SFP modules m Two Fibre Channel ports SFP modules m One x4 PCI E cable connector m One RS 232 Serial Management port RJ 45 connector m One LAN Management port RJ 45 connector m Three User I O and One Power Management Zone 3 connectors Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear Transition Module User s Guide April 2009 4 2 1 4 2 2 4 2 3 4 2 4 The Sun Netra CP32x0 ARTM FC contains a x8 PCI E connection that complies with the AMC 1 specification This PCI E is switched into four x4 ports one to each of the two Ethernet controllers one to a x4 PCI E cable connector and one to the Fibre Channel controller The onboard Emulex IOC3532 controller supports two Fibre Channel ports with fabric switching for high speed and high capacity storage access The two onboard Intel 82571EB controllers support four fixed GbE copper port
46. x01 Platform Event 0x02 Sensor Device Commands Sensor Event NetFn 0x04 Set Event Receiver 0x00 Get Event Receiver 0x01 Event Message 0x02 Get Device SDR Info 0x20 Get Device SDR 0x21 Reserve Device SDR Repository 0x22 Get Sensor Reading 0x2D Set Sensor Hysteresis 0x24 Get Sensor Hysteresis 0x25 Set Sensor Thresholds 0x26 Get Sensor Thresholds 0x27 FRU Device Commands Storage NetFn 0x0A Get FRU Inventory Area 0x10 Read FRU Data 0x11 Write FRU Data 0x12 Chapter 3 MMC and IPMI 3 3 TABLE 3 1 IPMI Commands Continued Request CMD Application Extension Commands Extension NetFn 0x2C Get PICMG Properties 0x00 FRU Control 0x04 Get FRU LED Properties 0x05 Get LED Color Capabilities 0x06 Set FRU LED State 0x07 Get FRU LED State 0x08 Get Device Record Locator ID 0x0D Set AMC Port State 0x19 Get AMC Port State 0x1A OEM Extension Commands OEM NetFn 0x32 SDR Initialization 0x20 FRU Initialization 0x21 HPM 1 Extension Commands Extension NetFn 0x2C Get target upgrade capabilities Ox2E Get component properties Ox2F Abort firmware upgrade 0x30 Initiate upgrade action 0x31 Upload firmware block 0x32 Finish firmware upload 0x33 Get upgrade status 0x34 Activate firmware 0x35 Query self test results 0x36 Query rollback status 0x37 Initiate manual rollback 0x38 3 4 Sun Netra CP32x0 Quad GbE Dual Fibre Channel Advanced Rear T