1. SPARC Enterprise M4000 M5000 Servers Product Notes 5 2 In place of the removed nut and ring attach the E Ring included in the rack mount kit 3 3 Insert the server all the way seated in the rack to lock it in place 6 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 Hardware Documentation Updates TABLE 2 lists known documentation updates TABLE 2 Documentation Updates Title All SPARC Enterprise M4000 M5000 Servers documentation SPARC Enterprise M4000 M5000 Servers Site Planning Guide SPARC Enterprise M4000 M5000 Servers Installation Guide SPARC Enterprise M4000 M5000 Servers Installation Guide SPARC Enterprise M4000 M5000 Servers Service Manual Page Number 1 7 2 8 3 3 1 4 Update All DVD references are now referred to as CD RW DVD RW Updated glossary terms External I O Expansion Unit A rack mountable device to add on PCI slots It is connected to the system s I O unit through the PCIe connection and contains one or two I O boats I O boat An I O unit in the External I O Expansion Unit The I O boat connects to a PCI Express PCIe slot through a PCIe switch or a PCI X bridge on the I O boat and offers either six PCI X slots or six PCle slots TABLE 1 3 Midrange Servers Physical Specifications Correct numerical value of Depth is 810mm 31 9 in for the SPARC Enterprise M4000 M5000 servers
2. TABLE 2 3 Powercords See Cable Connections on page 10 for the changes 3 3 Connecting the Administration Console The RJ 11 connector at the top of Figure 3 1 was not labelled The RJ 11 connector is not for connection to TNV circuits Do not use this connector 1 3 4 Handling Components The following caution will be added Caution In the PCI cassette part when removing cables such as LAN cable if your finger can t reach the latch lock of the connector press the latch with a flathead screwdriver to remove the cable Forcing your finger into the clearance can cause damage to the PCI card SPARC Enterprise M4000 M5000 Servers Product Notes 7 TABLE2 Documentation Updates Continued Title Page Number Update SPARC Enterprise 4 11 M4000 M5000 Servers Service Manual SPARC Enterprise 8 5 M4000 M5000 Servers Service Manual SPARC Enterprise 8 6 M4000 M5000 Servers Service Manual SPARC Enterprise M4000 M5000 Servers Service Manual 4 4 3 Powering the Server Off Manually Step 4 Verify the state of the status XSCF STANDBY LED on the operator panel is off should be replaced with the following description Verify the state of the status Power LED on the operator panel is off 8 1 2 Removing the PCI Cassette The cable management arm of the SPARC Enterprise M4000 server will not be supported The following note will be deleted accordingly Note The cable managemen
3. ou des soci t s affili es Ce document et le produit et les technologies qu il d crit peuvent inclure des droits de propri t intellectuelle de parties tierces prot g s par copyright et ou c d s sous licence par des fournisseurs a Fujitsu Limited et ou Sun Microsystems Inc y compris des logiciels et des technologies relatives aux polices de caract res Par limites du GPL ou du LGPL une copie du code source r gi par le GPL ou LGPL comme applicable est sur demande vers la fin utilsateur disponible veuillez contacter Fujitsu Limted ou Sun Microsystems Inc Cette distribution peut comprendre des composants d velopp s par des tierces parties Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Java Netra Solaris Sun Ray Answerbook2 docs sun com OpenBoot et Sun Fire sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Fujitsu et le logo Fujitsu sont des marques d pos es de Fujitsu Limited Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une
4. 16A 250V 3PIN with IEC320 C20 10 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 Updates of the SPARC Enterprise M4000 M5000 Servers Service Manual The following information supersedes the information in the SPARC Enterprise M4000 M5000 Servers Service Manual Installing the PCI Cassette Caution Do not force the PCI cassette into a slot Doing so can cause damage to the cassette and server Align the PCI cassette on the gray plastic guide and install it into the slot Lock the lever into place to seat the cassette Note As the lever is moved pressure will build up then just prior to locking into place the pressure will suddenly release If the lever locks in place without the pressure release the card may not be seated correctly If this happens the card should be removed and reinstalled Note When you insert the PCI cassette using hot swap the cassette is automatically powered on and configured Check that the power LED on the cassette is LIT to be certain the cassette is correctly seated Connect all cables to the PCI cassette and reconnect the cable management arm if necessaty DIMM Replacement The DIMMs are cold FRU replacement components The entire server must be powered off and the power cords disconnected to replace the DIMMs You can mount up to 4 memory boards on the SPARC Enterprise M4000 server and up to 8 memory boards on the SPARC
5. Enterprise M5000 server The DIMMs on the memory board are grouped into group A and group B SPARC Enterprise M4000 M5000 Servers Product Notes 11 Here are the DIMM mount conditions DIMM mounting rules m Four 4 DIMMs per group can be mounted m Capacity of the DIMMs in group A must be equal to or larger than the capacity of the DIMMs in group B m The capacity of the DIMMs in group B must be equal to or less than the capacity of the DIMMs in group A DIMMs in group B are optional m For both groups DIMMs must be of the same capacity and rank within a group DIMMs of different capacity cannot be mixed in a group 12 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 Software Issues This section describes software specific issues and workarounds XCP Issues and Workarounds TABLE 5 lists known XCP issues and possible workarounds TABLE5 XCP Issues and Workarounds ID Description Workaround RTIF1 All domains must be powered off before Power off domains before using the 070418 004 upgrading the XCP firmware flashupdate 8 command to upgrade XCP firmware RTIF1 If you log in to the XSCF while it is still Log out of the bash prompt and wait for the 070418 005 booting you may get a bash prompt instead XSCF to finish booting of the XSCF gt prompt and be unable to perform most operations RTIF1 While XSCF is running error message of Check that XSCF is started If not started us
6. October 2007 Fujitsu Welcomes Your Comments If you have any comments or requests regarding this manual or if you find any unclear statements in the manual please state your points specifically and forward it to a sales representative or a certified service engineer Please include the title and part number of your document with your feedback Revision History Edition Revised Section Details 02 Supported Versions of Firmware and Software Modification of description about the support of Capacity on Demand function Specific Issues and Workarounds Modification and addition of issues and workarounds which found after the 01 version release Documentation Updates Addition of articles about the documentation updates 03 Specific Issues and Workarounds Modification and addition of issues and workarounds which found after the 02 version release Documentation Updates Addition of articles about the documentation updates 04 Specific Issues and Workarounds Modification and addition of issues and Documentation Updates workarounds which found after the 03 version release Addition of articles about the documentation updates Preface ix x SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 SPARC Enterprise M4000 M5000 Servers Product Notes These product notes contain late breaking information about the SPARC Enterprise M4000 M5000 server hardware software or documen
7. QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE O A L ABSENCE DE CONTREFACON Contents Preface vii Technical Support vii Software Resources vii Accessing Documentation viii Fujitsu Welcomes Your Comments ix Revision History ix SPARC Enterprise M4000 M5000 Servers Product Notes 1 Supported Versions of Firmware and Software 1 Patch Information 2 Solaris Patch Information 2 Known Issues 3 General Functionality Issues and Limitations 3 Hardware Installation and Service Issues 4 Specific Issues and Workarounds 4 About the interference of nut 5 Hardware Documentation Updates 7 Electrical Specifications 9 Cable Connections 10 Updates of the SPARC Enterprise M4000 M5000 Servers Service Manual 11 Installing the PCI Cassette 11 DIMM Replacement 11 Software Issues 13 XCP Issues and Workarounds 13 Solaris Issues and Workarounds 16 Identifying Permanent Memory in a Target Board 26 Software Documentation Updates 27 vi SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 Preface These product notes contain late breaking information about the SPARC Enterprise M4000 M5000 server hardware software or documentation that became known after the documentation set was published Technical Support If you have technical questions or issues that are not addressed in the SPARC Enterprise M4000 M5000 servers documentation contact a sales representative or a certified servi
8. when running hotplug Perform cfgadm c disconnect to cfgadm to configure a previously completely remove the card After waiting at unconfigured card The message WARNING least 10 seconds the card may be configured PCI Expansion ROM is not accessible will be back into the domain using the cfgadm c seen on the console shortly before the system configure command panic The following cards are affected by this defect e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter 6556742 The system panics when DiskSuite can not Panic can be avoided when a duplicated copy read the metadb during DR This bug affects the following cards e SG XPCIE2FC QF4 4Gb PCI e Dual Port Fibre Channel HBA e SG XPCIE1FC QF4 4Gb PCI e Single Port Fibre Channel HBA e SG XPCI2FC QF4 4Gb PCI X Dual Port Fibre Channel HBA e SG XPCIIFC QF4 4Gb PCI X Single Port Fibre Channel HBA of the metadb is accessible via another Host Bus Adaptor Or you can apply patch 125166 06 SPARC Enterprise M4000 M5000 Servers Product Notes 23 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CR ID Description Workaround 6559504 Messages of the form nxge NOTICE These messages can be safely ignored nxge_ipp_eccue_valid_check rd_ptr nnn wr_ptr nnn will be observed on the console with the following cards X4447A Z PCI e Quad port Gigabit Ethernet Adapte
9. 0 M5000 Servers Product Notes 21 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CRID Description Workaround 6534471 Domain may panic Add the following line to etc system and reboot the domain set heaplp use_stlb 0 This bug has been fixed by 125100 06 6535564 PCI hot plug to PCI slot 0 1 or External IO There is no workaround Use DR instead of Expansion Unit may fail on XSB added by DR PCI hot plug if need to add or remove PCI card on the XSB 6536564 showlogs 8 and showstatus 8 command To avoid this problem issue the following on XSCF might report wrong I O component commands on the domain due to wrong diagnosis by Solaris Fault management Architecture when faults in I O cd usr platform SUNW SPARC devices occur Enterprise lib fm topo plugins mv ioboard so ioboard so orig svcadm restart fmd If the following messages are displayed on the domain contact a sales representative or a certified service engineer Example SUNW MSG ID SUNOS 8000 1L TYPE Defect VER 1 SEVERITY Minor EVENT TIME Sun May 6 18 22 24 PDT 2007 PLATFORM SUNW SPARC Enterprise CSN BE80601007 HOSTNAME sparc This bug has been fixed in 125369 05 6537511 Bluetooth partner is hung during security tests Restart application server execution 6539084 Sun PCIe Quad port Gigabit Ethernet Adapter There is no workaround Check for the UTP card X4447A Z might panic during a availability of a patch for this defect reboot Th
10. 90 Domain may cause a panic when To mask this error add the following entry to deleteboard 8 command for kernel board the etc system file by using Dynamic Reconfiguration DR set drmach fmem timeout 30 6522017 DR and ZFS may not be used in the same Set the maximum size of the ZFS ARC lower domain 6522433 After the CPU hardware error occurred the Check system status on XSCF fmdump 1M command on the domain may display an incorrect faulty component 6525010 PCIe correctable errors can be recorded in the Add the following entry to etc system to FMA error log prevent the problem set pcie pcie_aer_ce_mask 0x2001 20 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CR ID Description Workaround 6527811 showhardconf 8 on XSCF can not display No workaround is available at this time PCI card information that is installed in In case of each PCI card in the External I O External I O Expansion Unit if the External Expansion Unit is configured using PCI I O Expansion Unit is configured using PCI hotplug the PCI card information is displayed hotplug correctly 6529479 ereport io ddi fm capability error messages None available at this time Ignore the may be logged in ereport during system messages reboot 6529714 Warning messages occur while trying to No workaround available at this time configure more than four X4447A
11. CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Unless otherwise expressly set forth in such agreement to the extent allowed by applicable law in no event shall Fujitsu Limited Sun Microsystems Inc or any of their affiliates have any liability to any third party under any legal theory for any loss of revenues or profits loss of use or data or business interruptions or for any indirect special incidental or consequential damages even if advised of the possibility of such damages DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Ji ca Adobe PostScript Copyright 2007 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A et FUJITSU LIMITED 1 1 Kamikodanaka 4 chome Nakahara ku Kawasaki shi Kanagawa ken 211 8588 Japon Tous droits r serv s Entr e et revue tecnical fournies par Fujitsu Limited sur des parties de ce mat riel Sun Microsystems Inc et Fujitsu Limited d tiennent et contrdlent toutes deux des droits de propri t intellectuelle relat
12. Example system status on XSCF SUNW MSG ID FMD 8000 11 TYPE Defect VER 1 SEVERITY Minor EVENT TIME Tue Jan 9 20 45 08 JST 2007 PLATFORM SUNW SPARC Enterprise CSN 2030636002 HOSTNAME P2 DC1 16 d0 6502750 Notification message for inserted or removed None available at this time card by PCI hot plug may not output 6508432 Many correctable errors CE may occur and Set the following to etc system and then despite these are the correctable errors reboot the domain domain may panic set pcie pcie aer ce mask 0x2001 6508434 The domain may panic when an additional Do not insert a different type of PCI X card on PCI X card is installed or a PCI X card is the same PCI slot card by using PCI hot plug replaced by using PCI hot plug 6509337 s10s_u3 wanboot fails The server returned None available at this time 416 Requested Range Not Satisfiable 6510779 On a large single domain configuration the There is no workaround Check for the system may incorrectly report very high load availability of a patch for this defect average at times 6510861 When Dual Channel Ultra320 SCSI Card To mask these errors with Dual Channel SEOX7SC2F SEOX7SC2X is mounted Ultra320 SCSI Card SEOX7SC2F SEOX7SC2X correctable errors CE occur and system may add the following entry to the etc system file panic and then reboot the system set pcie pcie_aer_ce_mask 0x31c1 6511374 Unexpected error messages may be displayed This message can be sa
13. Information The following patches are mandatory for Sun SPARC Enterprise M4000 M5000 servers running Solaris 10 11 06 OS 118833 36 Install 118833 36 before 125100 04 125100 04 or later 120068 03 or later 123839 07 or later 125424 01 or later m 125075 01 or later Note See Software Resources on page vii for information on how to find the latest patches Installation information and README files are included in the patch download 2 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 Known Issues This section describes known issues in this release General Functionality Issues and Limitations Because the term admin will be reserved for the system use in next version of XCP please avoid using it to user account name If you use the term admin to user account name you have to delete it before upgrading the XCP Dynamic Reconfiguration DR is not recommended in cases below due to the following restrictions on the DR addboard 8 deleteboard 8 and moveboard 8 commands Please contact your Sales representative or Technical Support for additional information and software support u The target board SB XSB with optional I O cards because of some restrictions on specific cards Caution Use of DR in an unsupported configuration might result in a domain panic or might hang the system Domains using the ZFS file system can not use Reconfigura
14. RTIF1 showaudit all shows a long list of defaults 070418 025 in the policy section after the database is cleared RTIF1 When you have updated the etc ttydefs file of 070528 001 Solaris to disable the console flow control you cannot disable the console flow control on the telnet via a server RTIF1 While XSCF is running watchdog timeout 070528 002 may occur and XSCF may reboot RTIF1 When connected to telnet the login or the 070802 001 password prompt doesn t appear RTIF1 When remote power control mode of 070824 001 interlocking mechanism for power supply to domain is enabled after XSCF Unit is replaced the interlocking for power supply by RCI cannot work RTIF1 When the snapshot CLI attempts to write to a 070904 002 USB stick that has write protect set results in an I O error RTIF1 An incorrect domain state is reported After 070904 003 the command sendbreak to domain is issued showdomainstatus continues to show the state as Running when the domain is actually at ok prompt RTIF1 The latest communication field in 070904 004 showarchiving is not updated regularly Ignore this event Update the database with the following setaudit a opl enable setaudit a opl default None available at this time Check that XSCF is started If not started use the rebootxsc 8 command to restart XSCF or stop all the domains and then execute the system power off on AC OFF ON Disconnect the telnet sessi
15. TION CONTRAIRE EXPRESSEMENT STIPUL E DANS CE CONTRAT FUJITSU LIMITED SUN MICROSYSTEMS INC ET LES SOCI T S AFFILI ES REJETTENT TOUTE REPRESENTATION OU TOUTE GARANTIE QUELLE QU EN SOIT LA NATURE EXPRESSE OU IMPLICITE CONCERNANT CE PRODUIT CETTE TECHNOLOGIE OU CE DOCUMENT LESQUELS SONT FOURNIS EN L TAT EN OUTRE TOUTES LES CONDITIONS REPRESENTATIONS ET GARANTIES EXPRESSES OU TACITES Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE LA QUALIT MARCHANDE L APTITUDE A UNE UTILISATION PARTICULI RE OU L ABSENCE DE CONTREFA ON SONT EXCLUES DANS LA MESURE AUTORIS E PAR LA LOI APPLICABLE Sauf mention contraire express ment stipul e dans ce contrat dans la mesure autoris e par la loi applicable en aucun cas Fujitsu Limited Sun Microsystems Inc ou l une de leurs filiales ne sauraient tre tenues responsables envers une quelconque partie tierce sous quelque th orie juridique que ce soit de tout manque gagner ou de perte de profit de probl mes d utilisation ou de perte de donn es ou d interruptions d activit s ou de tout dommage indirect sp cial secondaire ou cons cutif m me si ces entit s ont t pr alablement inform es d une telle ventualit LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA
16. Z or X1027A Z1 cards into one I O Boat 6530178 DR addboard 8 command can hang Once There is no workaround Check availability of problem is observed further DR operations are a patch for this bug blocked Recovery requires reboot of the domain 6530288 Ap_Id format may not be shown correctly by None available at this time cfgadm 1M command 6530753 Some of the PCI slots in the External I O Use one of the following operations to display Expansion Unit PCI slots are not displayed all of the PCI slots during a normal boot operation boot r at open boot prompt devfsadm C at Solaris prompt cfgadm twice at Solaris prompt 6531036 The error message network There is no workaround initialization failed appears repeatedly after a boot net installation 6531668 System hangs when executing parallel hot No workaround available at this time plug operation with SP DR in suspend phase 6532215 volfs or dscp service may fail when domain is Restart the service if the failure is observed To booted svc platform sun4u dscp default Method lib svc method svc dscp start failed with exit status 95 svc system filesystem volfs defaul t Method or service exit timed out Killing contract 59 avoid the problem issue the following commands svccfg s dscp setprop start timeout_seconds count 300 svccfg s volfs setprop start timeout_seconds count 300 svcadm refresh dscp svcadm refresh volfs SPARC Enterprise M400
17. architecture d velopp e par Sun Microsystems Inc SPARC64 est une marques d pos e de SPARC International Inc utilis e sous le permis par Fujitsu Microelectronics Inc et Fujitsu Limited L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun Droits du gouvernement am ricain logiciel commercial Les utilisateurs du gouvernement am ricain sont soumis aux contrats de licence standard de Sun Microsystems Inc et de Fujitsu Limited ainsi qu aux clauses applicables stipul es dans le FAR et ses suppl ments Avis de non responsabilit les seules garanties octroy es par Fujitsu Limited Sun Microsystems Inc ou toute soci t affili e de l une ou l autre entit en rapport avec ce document ou tout produit ou toute technologie d crit e dans les pr sentes correspondent aux garanties express ment stipul es dans le contrat de licence r gissant le produit ou la technologie fourni e SAUF MEN
18. ce engineer Software Resources The Solaris Operating System and Sun Java Enterprise System software are preinstalled on your SPARC Enterprise M4000 M5000 servers Contact a sales representative or a certified service engineer for software resources for your SPARC Enterprise M4000 M5000 servers vii Note For latest patch information go to Global Site http www fujitsu com global support software security products s patch info Japanese Site http software fujitsu com jp security products others unix index html North American Site https download computers us fujitsu com Installation information and README files are included in the patch download Accessing Documentation Instructions for installing administering and using your SPARC Enterprise M4000 M5000 servers are provided in the SPARC Enterprise M4000 M5000 servers documentation set The documentation set is available for download from the following website Global Site http www fujitsu com sparcenterprise manual Japanese Site http primeserver fujitsu com sparcenterprise manual North American Site https download computers us fujitsu com Note Information in these product notes supersedes the information in the SPARC Enterprise M4000 M5000 servers documentation set Solaris documentation is available at http www sun com documentation viii SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041
19. co FUJITSU SPARC Enterprise M4000 M5000 Servers Product Notes For XCP version 1041 Copyright 2007 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A and FUJITSU LIMITED 1 1 Kamikodanaka 4 chome Nakahara ku Kawasaki shi Kanagawa ken 211 8588 Japan All rights reserved Sun Microsystems Inc and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in this document and such products technology and this document are protected by copyright laws patents and other intellectual property laws and international treaties The intellectual property rights of Sun Microsystems Inc and Fujitsu Limited in such products technology and this document include without limitation one or more of the United States patents listed at http www sun com patents and one or more additional patents or patent applications in the United States or other countries This document and the product and technology to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of such product or technology or of this document may be reproduced in any form by any means without prior written a thorization of Fujitsu Limited and Sun Microsystems Inc and their applicable licensors if any The furnishing of this document to you does not give you any rights or licenses express or implied with respect to the product o
20. e 070418 009 OOM kill might be displayed to XSCF the reboot xscf 8 command to restart XSCF console and process may go down and or or stop all the domains and then execute the watchdog timeout may occur and XSCF may system power off on AC OFF ON reboot RTIF1 The showdomainstatus acommandshows Use the showboards command to check the 070418 010 domain status as Powered Off but the status of domain power showboards a command shows the domain The showdomainstatus command takes a is testing longer time to show the correct status RTIF1 Some commands that update configuration Do not cancel set commands They appear to 070418 011 data take a relatively long time to execute hang but eventually complete in about 30 seconds RTIF1 The fault memory block ue is encountered An uncorrectable error exists in a DIMM and 070418 012 and reported periodically the DIMM should be replaced RTIF1 When using the XSCF Web to import a Import again a firmware image Reboot the 070418 020 firmware image if the image is corrupted the XSCF Unit then use the flashupdate flashupdate command might later report an internal error command again to clear the internal error SPARC Enterprise M4000 M5000 Servers Product Notes 13 TABLE5 XCP Issues and Workarounds Continued ID Description Workaround RTIF1 Using the rebootxscf 8 command may 070418 023 result in a process down error and possibly an FMA event with MSG ID SCF 8005 NE
21. e M4000 M5000 M8000 M9000 Servers XSCF Reference Manual if not otherwise specified also apply to the man pages which XSCF provides And they supersede the information on the man pages TABLE 7 lists known documentation updates TABLE7 Documentation Updates Title Page Number Update All SPARC Enterprise M4000 M5000 servers documentation ioxadm 8 man page showldap 8 man page showlookup 8 man page showemailreport 8 man page setaudit 8 man page showaudit 8 man page All DVD references are now referred to as CD RW DVD RW The required privileges for the ioxadm 8 command are as follows Required Privileges Commands platop env list platadm env list locator poweroff poweron fieldend env list locator poweroff poweron reset setled The man pages for showldap 8 showlookup 8 and showemailreport 8 do not state that these commands are available with the fieldeng privilege The setaudit 8 and showaudit 8 man pages are incorrect with respect to audit class information The following are the audit classes and their values ACS_SYSTEM 1 ACS_WRITE 2 ACS_READ 4 ACS_LOGIN 8 ACS_AUDIT 16 ACS_DOMAIN 32 ACS_USER 64 ACS PLATFORM 128 ACS_MODES 256 SPARC Enterprise M4000 M5000 Servers Product Notes 27 TABLE7 Documentation Updates Continued Title Page Number Update SPARC Enterprise 2 27 2 5 Operation Management M4000 M5000 M8000 The following sections will be added M9000 Se
22. fely ignored on console after changing the system configuration Example WARNING Translation error source LSB0 B0 0 PA 3c000000000 target LSB0 B0 20000000 SPARC Enterprise M4000 M5000 Servers Product Notes 19 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CR ID Description Workaround 6515648 Replumb Failed error appears when Once the DR operation is complete it can be dr 0 SB1 memory fails plumbed up manually Example steps to re plumb the interface manually ifconfig interface plumb Xxxx xxXx XXX XXX netmask broadcast up ifconfig interface group group name ifconfig interface addif xxx XXX XXX XXX failover deprecated up This workaround assumes that the etc hostname interface file is correctly configured for the IPMP group and does not need any modification The IP addresses used in the example above should match what was previously used and what matches the etc hostname lt interface gt file 6516135 Ap_Id format and devices may not be shown Use the following operations to display all of correctly by cfgadm 1M the PCI slots 1 devfsadm at Solaris prompt 2 cfgadm 6519290 Large amounts of I O on swap devices can Set the following to etc system and then cause the system to appear hung by over reboot the domain welling the I O system The amount of I O set maxfastscan 0x2000 required can be generated through a number of ways eg memory shortage heavy use of tmp etc 65209
23. he following important message will be added Note If you replace the XSCF unit and the operator panel simultaneously system will not operate normally Execute the showhardconf command or the showstatus command to confirm that the component replaced earlier is operating normally before replacing the subsequent FRU 11 2 DIMM Replacement Service Manual SPARC Enterprise M4000 M5000 Servers Service Manual C 7 See DIMM Replacement on page 11 for the changes TABLE C 5 Power Supply Feature See Electrical Specifications on page 9 for the changes Electrical Specifications The following changes belong in the SPARC Enterprise M4000 M5000 Servers Service Manual TABLE3 Power Supply Features SPARC Enterprise M4000 SPARC Enterprise M5000 Power draw maximum Volt Ampere Heat 2016W 2058 VA 6879 BTUs hr 7258 kJ hr 3738W 3815 VA 12754 BTUs hr 13457 kJ hr SPARC Enterprise M4000 M5000 Servers Product Notes 9 Cable Connections The following changes belong in the SPARC Enterprise M4000 M5000 Servers Installation Guide TABLE 4 Powercords System Location Powercord Type SPARC Enterprise M4000 Server SPARC Enterprise M5000 Server Americas Taiwan Japan Korea RoTW Americas Taiwan Japan Korea RoTW NEMA L5 15 125V 15A NEMA L6 20 250V 20A IEC60309 16A 250V 3PIN with IEC320 C20 NEMA L5 15 125V 15A NEMA L6 20 250V 20A IEC60309
24. ifs aux produits et technologies d crits dans ce document De m me ces produits technologies et ce document sont prot g s par des lois sur le copyright des brevets d autres lois sur la propri t intellectuelle et des trait s internationaux Les droits de propri t intellectuelle de Sun Microsystems Inc et Fujitsu Limited concernant ces produits ces technologies et ce document comprennent sans que cette liste soit exhaustive un ou plusieurs des brevets d pos s aux Etats Unis et indiqu s l adresse http www sun com patents de m me qu un ou plusieurs brevets ou applications brevet es suppl mentaires aux Etats Unis et dans d autres pays Ce document le produit et les technologies aff rents sont exclusivement distribu s avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit de ces technologies ou de ce document ne peut tre reproduite sous quelque forme que ce soit par quelque moyen que ce soit sans l autorisation crite pr alable de Fujitsu Limited et de Sun Microsystems Inc et de leurs ventuels bailleurs de licence Ce document bien qu il vous ait t fourni ne vous confere aucun droit et aucune licence expresses ou tacites concernant le produit ou la technologie auxquels il se rapporte Par ailleurs il ne contient ni ne repr sente aucun engagement de quelque type que ce soit de la part de Fujitsu Limited ou de Sun Microsystems Inc
25. ion describes hardware specific issues and workarounds Specific Issues and Workarounds TABLE 1 lists known hardware issues and possible workarounds TABLE1 Hardware Issues and Workarounds CR ID Description Workaround 6433420 The domain console might display a Mailbox Issue a reset all command from the OBP timeout or IOCB interrupt timeout error during OK prompt and reboot boot 6488846 During boot the domain console might display Check for the availability of the latest a checksum error for the SG X PCI2SCSIU320 controller card firmware Z SCSI controller I O card 6498780 On the SPARC Enterprise M4000 M5000 The PCI or PCI X plug in adapter card might servers the OpenBoot PROM OBP might not detect the on board disk HDD boot device Performing a boot disk results in a console message Can t locate boot device not be seated correctly Reseat the card in slot 0 of the IOU 4 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 About the interference of nut When you mount the SPARC Enterprise M4000 or M5000 server on the 19 inch rack as you insert it all the way seated in the rack the nut anchoring the bezel may interfere with the rack column and the server may fail to be seated correctly In such a case please replace the bezel anchoring nut and ring with the E Ring 1 Remove the interfering bezel anchoring nut and ring Ring Bezel Anchoring nut O
26. is bug has been fixed in 125670 01 6539909 Do not use the following I O cards for network When running Solaris 10 11 06 use an access when you are using the boot net install command to install the Solaris OS e X4447A Z X4447A Z PCIe Quad port Gigabit Ethernet Adapter UTP e X1027A Z X1027A Z PCIe Dual 10 Gigabit Ethernet Fiber XFP alternate type of network card or onboard network device to install the Solaris OS via the network This defect does not exist in Solaris 10 8 07 22 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CR ID Description Workaround 6542632 Memory leak in PCle module if driver attach There is no workaround Check for the fails availability of a patch for this defect 6545685 If the system has detected Correctable Memory Increase the memory patrol timeout values Errors CE at power on self test POST the used via the following setting in domains might incorrectly degrade 4 or 8 etc system DIMMs set mc opl mc max rewrite loop 20000 6546188 The system panics when running hotplug There is no workaround Check for the cfgadm and DR operations addboard and availability of a patch for this defect deleteboard on the following cards e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter 6551356 The system panics
27. is defect To recover add the board back to the domain with the addboard command then retry the deleteboard command SPARC Enterprise M4000 M5000 Servers Product Notes 25 Identifying Permanent Memory in a Target Board 1 Log in to XSCE 2 Execute the following command XSCF gt showdevices d domain_id The following example shows a display of the showdevices d command where 0 is the domain_id XSCF gt showdevices Memory board DID XSB mem MB 00 00 0 8192 00 00 2 8192 00 00 3 8192 d 0 perm mem MB 1674 base address 0x0000000000000000 0x000003c000000000 0x0000034000000000 domain target deleted remaining mem MB XSB mem MB mem MB 24576 24576 24576 The entry for column 4 perm mem MB indicates the presence of permanent memory if the value is non zero The example shows permanent memory on 00 2 with 1674 MB If the board includes permanent memory when you execute the deleteboard command or the moveboard command the following notice appears System may be temporarily suspended proceed y n 26 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 Software Documentation Updates This section contains late breaking software information that became known after the documentation set was published and corrections in the SPARC Enterprise M4000 M5000 Servers Software documentation The corrections for SPARC Enterpris
28. ll function normally during this using the setemailreport CLI may block for up to 30 minutes time e The CLI can also be aborted by C Note that the operation disabling emailreport is completed even if C is used e showemailreport can be used to confirm that the service has been disabled SPARC Enterprise M4000 M5000 Servers Product Notes 15 TABLE 6 Solaris Issues and Workarounds TABLE 6 lists known issues and possible workarounds Specific Issues and Workarounds Concerning Solaris CR ID Description Workaround 6348554 6416224 6440061 6441349 6459540 Using the cfgadm c disconnect command on the following cards might hang the command during i_mdi_pi_offline e SG XPCIE2FC OF4 Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Channel PCI E HBA e SG XPCIE1FC QF4 Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCI E HBA SG XPCI2FC QF4 Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Channel PCI X HBA e SG XPCIIFC QF4 Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCI X HBA System performance can degrade using a single NIC card with more than 5 000 connections The domain console may display this message ipsec_check_inbound_policy Policy Failure for the incoming packet not secure The system may hang if there is an I O error in the system The DAT72 internal tape drive on SPARC Enterprise M4000 M5000 may time out during tape opera
29. on and try again After XSCF Unit is replaced configures the RCI again and sets the remote power control mode Do not attempt to use write protected USB devices for collecting snapshot There is no workaround This is expected behavior of the sendbreak operation Disabling and re enabling archiving refreshes the Latest communication field in showarchiving output 14 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE5 XCP Issues and Workarounds Continued ID Description Workaround RTIF1 Time can t be synchronized with the NTP Check the stratum value of the NTP server 070904 005 server The stratum value of XSCF is 5 The NTP server which the XSCF refers to must be a server on which the stratum value is smaller than 5 When you changed the NTP server to refer to reboot the XSCF When the stratum value has been set correctly and the time can t be synchronized use the showntp 8 command to check the jitter value to be displayed If this value is large please reboot the XSCF RTIF1 While executing the domain power on Execute the domain reset one more time or 070904 006 domain reset or DR in case the XSCF reboot power off the domain and then power on occurred the process may be aborted in some again or all of the XSB RTIF1 If an invalid SMTP server is configured a Wait for the CLI to complete The rest of the 070912 001 subsequent attempt to disable email service system wi
30. port Gigabit set ip ip soft rings cnt 0 Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter 6571370 Use of the following cards have been observed Add the following line in etc system and to cause data corruption in stress test under laboratory conditions X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter reboot set nxge nxge rx threshold hi 0 24 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE 6 Specific Issues and Workarounds Concerning Solaris Continued CR ID Description Workaround 6572593 6589833 6592302 fmdump 1M may show wrong faulty component when IOU hardware error occurs The DR addboard command might cause a system hang if you are adding a Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Channel PCI E HBA card SGXPCIE2FC QF4 at the same time that an SAP process is attempting to access storage devices attached to this card The chance of a system hang is increased if the following cards are used for heavy network traffic e X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter Unsuccessful DR operation leaves memory partially configured Check system status on XSCF There is no workaround Check for the availability of a patch for th
31. r UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter 6563785 Hot plug operation with the following cards After disconnecting a card wait for a few might fail if a card is disconnected and then seconds before re connecting immediately reconnected e SG XPCIE2SCSIU320Z Sun StorageTek PCI E Dual Port Ultra320 SCSI HBA SGXPCI2SCSILM320 Z Sun StorageTek PCI Dual Port Ultra320 SCSI HBA 6564332 Hot plug operations on Sun Crypto Version1 0 of the SCA6000 driver does not Accelerator SCA 6000 cards can cause SPARC support hot plug and should not be attempted Enterprise M4000 M5000 servers to panic or Version1 1 of the SCA6000 driver and hang firmware will support hot plug operations after the required bootstrap firmware upgrade has been performed 6564934 Performing a DR deleteboard operation ona Re configure the affected network interfaces board which includes Permanent Memory after the completion of the DR operation For when using the following network cards will basic network configuration procedures refer result in broken connections to the if manpage for more information X4447A Z PCI e Quad port Gigabit Ethernet Adapter UTP e X1027A Z1 PCI e Dual 10 Gigabit Ethernet Fiber XFP Low profile Adapter 6568417 After a successful CPU DR deleteboard Add the following line to etc system and operation the system panics when the reboot the system following network interfaces are in use X4447A Z PCI e Quad
32. r technology to which it pertains and this document does not contain or represent any commitment of any kind on the part of Fujitsu Limited or Sun Microsystems Inc or any affiliate of either of them This document and the product and technology described in this document may incorporate third party intellectual property copyrighted by and or licensed from suppliers to Fujitsu Limited and or Sun Microsystems Inc including software and font technology Per the terms of the GPL or LGPL a copy of the source code governed by the GPL or LGPL as applicable is available upon request by the End User Please contact Fujitsu Limited or Jan Microsystems Inc This distribution may include materials developed by third parties Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Java Netra Solaris Sun Ray Answerbook2 docs sun com OpenBoot and Sun Fire are trademarks or registered trademarks of Sun Microsystems Inc in the U S and other countries Fujitsu and the Fujitsu logo are registered trademarks of Fujitsu Limited All SPARC trademarks are used under license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architecture developed by Sun Microsy
33. rt fmd service Example svcadm restart fmd SUNW MSG ID FMD 8000 2K TYPE Defect VER 1 SEVERITY Minor az EVENT TIME Thu Feb 15 15 46 57 gst T avoid this problem in advance 3007 add rm f var fm fmd ckpt cpumem gt i diagnosis cpumem diagnosis in ARE SUNW SPARC ENteTpELSS lib svc method svc dumpadm file as below CSN BE80601007 HOSTNAME col2 ff em7 d0 We haven t run savecore on a dump device yet savedev none rm f var fm fmd ckpt cpumem diagnosis cpumem diagnosis 6498283 Using the DR deleteboard 8 command There is no workaround Check for the while psradm operations are running on a availability of a patch for this defect domain might cause a system panic 6499304 CPU isn t offlined and unexpected message is Check CPU status on XSCF displayed on console when many correctable error CE occurs Example SUNW MSG ID FMD 8000 11 TYPE Defect VER 1 SEVERITY Minor EVENT TIME Fri Feb 2 18 31 07 JST 2007 PLATFORM SPARC Enterprise CSN BE80601035 HOSTNAME FF2 35 0 18 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CR ID Description Workaround 6502204 Unexpected error messages may be displayed If you see unexpected messages use the XSCF on console on booting after CPU UE panic command showdomainstatus 8 to check
34. rtscts f 9600 This procedure is required only once 6481002 Installing the Solaris from the network using If you are using a Sun PCI E Dual Gigabit certain PCI Express cards may cause a panic Ethernet Adapter MMF card or a Sun PCI E Dual Gigabit Ethernet Adapter UTP card do not install the Solaris using either of these cards Instead use other network devices such as the onboard Gigabit Ethernet or another network device 6485555 On the SPARC Enterprise M4000 M5000 None available at this time servers On board Gigabit Ethernet NVRAM corruption could occur due to a race condition The window of opportunity for this race condition is very small 6495303 The use of a PCIe Dual Port Ultra320 SCSI Do not use this card in IOU Slot 1 on a SPARC controller card SG X PCIE2SCSIU3202 in IOU Slot 1 on a SPARC Enterprise M4000 M5000 server may result in a system panic Enterprise M4000 M5000 server SPARC Enterprise M4000 M5000 Servers Product Notes 17 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CRID Description Workaround 6496337 The cpumem diagnosis module may fail to If problem occurred implement the following load after uncorrectable error UE panic workaround Systems will function correctly but events 1 Remove the following file a o diagnosed by ka rm var fm fmd ckpt cpumem ne t is module will require manua diagosis epumem diagn sis iagnosis 5 2 Resta
35. rvers Dynamic 2 5 6 XSCF Failover Reconfiguration DR User s Guide An XSCF failover might prevent a DR operation from completing To check log in to the active XSCF check the status of the system board and if necessary repeat the DR operation 2 5 7 Kernel Memory Board Deletion If an XSCF failure or failover occurs during the Copy rename phase of a deleteboard 8 or moveboard 8 operation the Solaris OS may panic and display the following message Irrecoverable FMEM error error code If you see this message log in to the XSCF again to check status You may have to reboot the Solaris OS and on the XSCF check system board status specify the kernel memory board and repeat the DR operation 2 5 8 Deletion of Board with DVD Drive To delete the system board to which the server s DVD drive is connected execute the following steps 1 Stop the vold 1M daemon by disabling the volfs service usr sbin svcadm disable volfs 2 Execute the DR operation 3 Restart the vold 1M daemon by enabling the volfs service usr sbin svcadm enable volfs For details see the vold 1M Solaris man page 28 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007
36. stems Inc SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and Fujitsu Limited The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements United States Government Rights Commercial use U S Government users are subject to the standard government user license agreements of Sun Microsystems Inc and Fujitsu Limited and the applicable provisions of the FAR and its supplements Disclaimer The only warranties granted by Fujitsu Limited Sun Microsystems Inc or any affiliate of either of them in connection with this document or any product or technology described herein are those expressly set forth in the license agreement pursuant to which the product or technology is provided EXCEPT AS EXPRESSLY SET FORTH IN SUCH AGREEMENT FUJITSU LIMITED SUN MICROSYSTEMS INC AND THEIR AFFILIATES MAKE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND EXPRESS OR IMPLIED REGARDING SUCH PRODUCT OR TECHNOLOGY OR THIS DOCUMENT WHICH ARE ALL PROVIDED AS IS AND ALL EXPRESS OR IMPLIED
37. t arm of the SPARC Enterprise M4000 server might obstruct access to the PCI cassettes Do not force the arm out of the way of the cassettes because it will become permanently bent Pull the quick release button and disconnect the slide end of the arm Once disconnected the arm can be safely held out of the way when removing the cassettes Instead the following caution will be added Caution When removing cables such as LAN cable if your finger can t reach the latch lock of the connector press the latch with a flathead screwdriver to remove the cable Forcing your finger into the clearance can cause damage to the PCI card 8 1 3 Installing the PCI Cassette See Installing the PCI Cassette on page 11 for the changes 1 Power off the server This step includes turning the keyswitch to the Service position verifying the state of the LEDs and disconnecting power cables should be substituted with the following description This step includes turning the keyswitch to the Service position verifying that the Power LED is turned off and disconnecting power cables 8 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE2 Documentation Updates Continued Title Page Number Update SPARC Enterprise 9 1 CHAPTER 9 XSCF Unit Replacement M4000 M5000 Servers 15 1 CHAPTER 15 Operator Panel Replacement Service Manual SPARC Enterprise 11 7 M4000 M5000 Servers T
38. tation that became known after the documentation set was published m Supported Versions of Firmware and Software m Patch Information m Known Issues m Hardware Installation and Service Issues m Hardware Documentation Updates m Software Issues m Software Documentation Updates Supported Versions of Firmware and Software The following firmware and software versions are supported in this release m XSCF Control Package XCP 1041 or later Note When the XCP version preinstalled in your server is under XCP 1041 you must upgrade to XSCF Control Package XCP 1041 or later Use the web browser interface also known as the browser user interface BUI to import XCP firmware and then execute the flashupdate command to upgrade the XCP firmware with the XSCF Shell cause random panics Implement the workaround for CR ID 6534471 or check for the availability of a patch and install it immediately This bug has been fixed by 125100 06 Caution CR ID 6534471 Improper handling of large page in kernel memory may m The first version of the Solaris Operating System OS to support these servers is the Solaris 10 11 06 OS m XCP 1041 supports the External I O Expansion Unit m This XCP release does not support the Capacity On Demand COD feature Note For the offering schedule of COD product and External I O Expansion Unit please contact your sales representative Patch Information Solaris Patch
39. tion PCI Hotplug feature is not available for this release Please contact your sales representative or technical support for additional information and software support SPARC Enterprise M4000 M5000 servers are cold service machines Hot swapping of the CPU Memory board unit CMU I O Unit IOU or any eXtended System Control Facility XSCF unit is not supported The XSCF web browser interface also known as the browser user interface BUT has limited availability in this release It can be used for importing the XSCF firmware and it supports the snapshot 8 command Full log set collection function Use the command line interface CLI instead on the Service Processor and the domains for other activities Power off all domains before upgrading the XCP firmware In this release to conduct the maintenance work of COD board it is necessary to power off the system For 1027A Z X1027A Z PCle Dual 10 Gigabit Ethernet Fiber XFP cards these limits apply a Do not use more than two cards per domain u Do not use these cards in an External I O Expansion Unit SPARC Enterprise M4000 M5000 Servers Product Notes 3 m For 4447A 7 X4447A 7 PCIe Quad port Gigabit Ethernet Adapter UTP cards these maximum limits apply a No more than two cards per I O boat a No more than four cards in a SPARC Enterprise M4000 server m No more than eight cards in a SPARC Enterprise M5000 server Hardware Installation and Service Issues This sect
40. tions There is no workaround Check for the availability of a patch for this defect Use multiple NIC cards to split network connections This message can be safely ignored None available at this time Add the following definition to kernel drv st conf tape config list SEAGATE DAT DAT72 000 SEAGATE DAT DAT72 000 SEAGATE DA DAT72 000 SEAGATE DAT _DAT72 000 1 0x34 0 0x9639 4 0x00 0x8c 0x8c Ox8c 3 There are four spaces between SEAGATE DAT and DAT72 00 16 SPARC Enterprise M4000 M5000 Servers Product Notes for XCP Version 1041 October 2007 TABLE6 Specific Issues and Workarounds Concerning Solaris Continued CRID Description Workaround 6466617 Performing a hot plug operation with the PCI Pause a few seconds between the issue of each Express slot too quickly interrupts a PCI leaf cfgadm c command reset and fails creating a cfgadm Component system is busy error 6472153 If you create a Solaris Flash archive ona non Just after installing Solaris OS from a Solaris SPARC Enterprise M4000 M5000 sun4u server Flash archive telnet into the SPARC Enterprise and install it on a SPARC Enterprise M4000 M5000 server to reset the console s TTY M4000 M5000 sun4u server the console s TTY flags a follows flags will not be set correctly This can cause sttydefs r console the console to lose characters during stress sttydefs a console i 9600 hupcl opost onlcr c

Download Pdf Manuals

image

Related Search

Related Contents

Maytag AFD2535DEW Refrigerator User Manual    Page 1 Page 2 Page 3 ひびわれに沿ってコンクリート深部にまで 注入剤  Arctic Cove EVC700-MBPM016 Use and Care Manual  General Information  Powermate P-WLE-1639-[E] Parts list  Transcend Information 3-in-1 User's Manual  "取扱説明書"  POL–EKO–APARATURA sp.j.  Panasonic WV-SP509 CAD File  