Netra st D130 Installation and Maintenance Manual
Contents
1. FIGURE 1 9 Auto Termination Indication LEDs Lit in a Narrow SCSI Daisy Chain Internal Components Power Supply The Netra st D130 storage enclosure has a single power supply that provides power to the internal components The power supply in your system is either AC or DC powered 8 Netra st D130 Installation and Maintenance Manual November 1999 AC Version The power supplies on the AC version convert incoming AC voltage to outgoing DC voltages 2 OO AC power connector FIGURE 1 10 Netra st D130 Rear View AC Version DC Version The power supply on the DC version converts incoming 48 VDC voltage to outgoing DC voltages The DC version has two connectors so you can connect a single Netra st D130 storage enclosure to two different 48V DC power sources Each DC power source should have a 10 amp circuit breaker OO DC power connectors EEE FIGURE 1 11 Netra st D130 Rear View DC Version Cooling System The cooling requirements are as follows 1 Ensure adequate airflow through the system The internal fans can achieve a maximum airflow of approximately 30 cfm in free air 2 The air is drawn through the front of the enclosure and expelled from the rear of the enclosure Chapter 9 FIGURE 1 12 Airflow Requirements Front and Rear 3 Airflow requirements
2. FIGURE 2 10 Routing the Wires Out of the Bottom Portion of the Strain Relief Housing 3 Get the tie wrap and insert it into the bottom portion of the strain relief housing FIGURE 2 11 Securing the Wires to the Strain Relief Housing 4 Loop the tie wrap over the wires and back out of the strain relief housing and tighten the tie wrap to secure the wires to the strain relief housing 5 Lower the top portion of the strain relief housing so that the three prongs on the top portion insert into the openings in the DC connector and push the top and bottom portions of the strain relief housing together until they snap into place 22 Netra st D130 Installation and Maintenance Manual November 1999 FIGURE 2 12 Assembling the Strain Relief Housing Isolating the Chassis Ground Connection Every Netra st D130 storage enclosure is shipped out of the factory with the chassis ground connected to the common output return through two screws on the power supply at the rear of the enclosure If you want to isolate this connection follow the instructions in the Netra st D130 Product Notes Chapter 23 24 Netra st D130 Installation and Maintenance Manual November 1999 CHAPTER 3 Installing the Netra st D130 Storage Enclosure This chapter provides instructions on how to prepare the area connect the cables and power on the storage enclosure This chapter is organized as follows m Hardware Requirements on pag
3. Before you can install the Netra st D130 storage enclosure you must first prepare your host system and set the SCSI IDs for the drives v To Prepare the Host System 1 Read any Product Notes for updated product information 2 Prepare the site for the installation including determining site power and sizing requirements Refer to Appendix A for power size and weight statistics 3 Halt operations and power off your host system Refer to your host system documentation for instructions on powering off the system 4 Install a host adapter card into your host system if necessary Refer to the documentation that shipped with the adapter card for installation instructions 5 Have software documents on the system CD available during the installation 26 Netra st D130 Installation and Maintenance Manual November 1999 v To Set the SCSI IDs for the Drives 1 Determine which SCSI target addresses are available on your host system Refer to the Solaris Handbook for Sun Peripherals in the Solaris AnswerBook online documentation for information on how to determine which SCSI target IDs are available for your system 2 At the rear of the enclosure locate the SCSI ID switch SCSI IDs set to SCSI IDs set to 2 3 and 4 from 10 11 and 12 left to right from left to right ose 0 0 o e CAGE FIGURE 3 1 Locating the SCSI ID Switch 3 Mov
4. and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements RESTRICTED RIGHTS Use duplication or disclosure by the U S Government is subject to restrictions of FAR 52 227 14 g 2 6 87 and FAR 52 227 19 6 87 or DFAR 252 227 7015 b 6 95 and DFAR 227 7202 3 a DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 1999 Sun Microsystems Inc 901 San Antonio Road Palo Alto Californie 94303 4900 U S A Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la dis
5. 2 Once you have selected a disk slice for your UFS file system create a file system on the slice newfs dev rdsk cwtxdysz Refer to the new s 1M man page for more information 38 Netra st D130 Installation and Maintenance Manual November 1999 3 If necessary create a mount point for the new file system mkdir mount point where mount point is a fully qualified path name Refer to the mount 1M man page for more information 4 After the file system and mount point have been created modify the etc vfstab file to reflect the new file system See the v stab 4 man page for more details 5 Mount the new file system using the mount command mount mount point where mount point is the directory you created The file system is ready to be used Removing and Replacing a Disk Drive The Netra st D130 storage enclosure comes configured with 1 inch high drives The procedure for removing and replacing the drives differs only in the software you use to control the disks In all cases the hard disks are hot pluggable v To Remove a Disk Drive Caution If the Netra st D130 storage enclosure is running and a drive slot does not contain a disk drive or foam filler the Netra st D130 storage enclosure will not cool properly and may overheat If you are not replacing the disk drive immediately you must install a foam filler in the empty slot The foam fillers are air baffles They allow the system to maintain
6. Power Switch 5 SCSI ID Switch 5 Back Panel LEDs 6 Auto Termination Indication LEDs Lit in UltraSCSI or Wide SCSI Daisy Chain Auto Termination Indication LEDs Lit in a Narrow SCSI Daisy Chain 8 Netra st D130 Rear View AC Version 9 Netra st D130 Rear View DC Version 9 Airflow Requirements Front and Rear 10 Airflow Requirements Open Rack 10 Airflow Requirements Closed Rack 11 DC Connector 16 Strain Relief Housing 17 Cage Clamp Operating Lever 17 Power Connector on the DC Power Supply 17 Stripping the Insulation From the Wire 18 7 Opening the DC Connector Cage Clamp Using the Cage Clamp Operating Lever 19 vii viii GURE 2 7 GURE 2 8 GURE 2 9 GURE 2 10 GURE 2 11 GURE 2 12 GURE 3 1 GURE 3 2 GURE 3 3 GURE 3 4 GURE 3 5 GURE 3 6 GURE 3 7 GURE 3 8 GURE 4 1 GURE 4 2 GURE 4 3 Opening the DC Connector Cage Clamp Using a Screwdriver 20 Assembling the DC Input Power Cable 20 Inserting the Bottom Portion of the Strain Relief Housing 21 Routing the Wires Out of the Bottom Portion of the Strain Relief Housing 22 Securing the Wires to the Strain Relief Housing 22 Assembling the Strain Relief Housing 23 Locating the SCSI ID Switch 27 Netra st D130 Rear View AC Version 28 Daisy Chaining Netra st D130 Storage Enclosures 29 Daisy Chaining a Netra st D130 Storage Enclosure with a Narrow SCSI Device 30 Netra st D130 Rear View AC Version 31 Connecting the DC Grounding Cable 31
7. differ for an open rack system and a closed rack system as shown in the following illustrations U U LY d U E FIGURE 1 13 Airflow Requirements Open Rack 10 Netra st D130 Installation and Maintenance Manual November 1999 U N EG ES FIGURE 1 14 Airflow Requirements Closed Rack Caution If the Netra st D130 storage enclosure is installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may exceed the room ambient Ensure that the rack environment ambient temperature does not exceed 55 Celsius 131 Fahrenheit Disk Drives The disk drives in the Netra st D130 storage enclosure are all hot pluggable See the documentation that comes with your system for information about the drives installed in your system The SCSI IDs for the disk drives in the Netra st D130 storage enclosure are set using the SCSI ID switch at the rear of the enclosure Refer to the drive LEDs on the front of the Netra st D130 storage enclosure or the SCSI ID switch at the rear of the enclosure to determine the SCSI IDs that you have assigned to the drives in your enclosure Chapter 11 Foam Fillers If you ordered a Netra st D130 storage enclosure with fewer than three disk drives foam fillers occupy the holes for the empty
8. electrical ratings when determining the correct branch circuit rating for your installation Connect the AC power cable to the AC power connector RM Power connector e E e FIGURE 3 5 Netra st D130 Rear View AC Version DC Version Get a DC grounding cable and two star washers Position and align the DC grounding cable against the two DC grounding lug nuts at the rear of the Netra st D130 storage enclosure mu JOO DC connectors DC grounding lug nuts FIGURE3 6 Connecting the DC Grounding Cable Place the star washers between the DC grounding cable and the two bolts that you will use to secure one end of the grounding cable to the two lug nuts Tighten the two bolts to secure the grounding cable to the two lug nuts Secure the other end of the grounding cable to the earth ground in the building If you are installing the Netra st D130 storage enclosure in a rack you can secure the grounding cable to a a proper grounding point on the rack as long as the rack is properly grounded to the earth ground in the building Verify that the DC power source is off through the circuit breakers Chapter 31 Caution Do not proceed with these instructions until you have verified that the power is off to the DC power source through the circuit breakers 7 Verify that the DC input power cables are conn
9. host adapter corresponding to controller c2 and a drive was added to the second slot in a Netra st D130 storage enclosure with the SCSI ID switch in the leftmost position which assigns SCSI IDs 2 3 and 4 to the drives inside the enclosure the new drive appears as dev dsk c2t3d0s 0 7 and dev rdsk c2t3d0s 0 7 1 Use the drvconfig and disks commands to add the new device drvconfig f disks 2 Verify that the new disk has been added ls 1 dev dsk c1t3d0s where c1t3d0s is the expected device name for the new drive in the third slot The new disk drive is now available for use as a block or character device Refer to the sd 7 man pages for further details V To Configure a New Disk Drive Within Your Application Caution These procedures should be performed only by a qualified system administrator Performing hot plug operations on an active disk drive can result in data loss Use the following procedure to configure a slice single physical partition on a disk to be used with a UNIX file system UFS For instructions on configuring a disk within a Veritas VxVM or Solstice DiskSuite application refer to the documentation that came with your application 1 Verify that the device label meets your requirements You can use the prtvtoc command to inspect the label for your disk To modify the label use the format command Refer to the prtvtoc 1M and format 1M man pages for more information
10. storage enclosure a If you are returning a defective enclosure leave the drive bays empty If you are not returning a defective enclosure insert a foam filler in the empty drive slot 40 Netra st D130 Installation and Maintenance Manual November 1999 To Replace a Disk Drive Note You cannot mix and match capacities of disk drives in the Netra st D130 storage enclosure If necessary refer to the documentation that came with your Veritas VxVM or Solstice DiskSuite software for any procedures that you might have to perform before you can replace the disk drive Hold the locking handle on the disk drive open Slide the replacement disk drive into the vacant slot Gently push the drive until the locking handle engages Close the locking handle completely using gentle inward pressure Replace the front panel Chapter 41 42 Netra st D130 Installation and Maintenance Manual November 1999 APPENDIX A System Specifications This appendix gives the system specifications for the Netra st D130 storage enclosure m Physical Specifications on page 43 m Electrical Specifications on page 44 m Environmental Specifications on page 45 Physical Specifications TABLE A 1 Physical Specifications Measure Metric Width 43 6 cm Depth 47 2 cm Height 4 4 cm Weight without 5 9 kg disk drives Weight fully 8 16 kg loaded English 17 17 in 18 58 in 1 73 in 1 ra
11. to three 1 inch high drives FIGURE 1 2 Removing the Front Panel 2 Netra st D130 Installation and Maintenance Manual November 1999 Front Panel LEDs System Power LED System Summary Fault LED Disk Drive LEDs FIGURE 1 3 Front Panel LEDs TABLE 1 1 Front Panel LEDs LED Color Meaning Action System Power Green The enclosure is powered on No action is necessary Unlit The enclosure is powered off No action is necessary System Summary Fault Green Amber The enclosure is performing normally A component other than a disk drive has failed such as the power supply or a fan The System Summary Fault LED does not indicate if a disk drive has failed The Disk Drive LEDs give diagnostic information on the disk drives No action is necessary You must replace the entire Netra st D130 storage enclosure Remove all disk drives before returning the enclosure see To Remove a Disk Drive on page 39 Contact your local Sun service representative for more details Chapter 3 TABLE 1 1 LED Color Front Panel LEDs Continued Meaning Action Disk Drive Flashing green Unlit Solid green A disk drive is present in that slot but is not active The Disk Drive LED also gives the SCSI ID for that disk drive A disk drive is present in that slot and is acti
12. Connecting the DC Input Power Cable to the DC Connector 32 Disconnecting the DC Input Power Cable from the DC Connector 33 Removing the Front Panel 36 Adding a Disk Drive 37 Removing and Replacing a Disk Drive 40 Netra st D130 Installation and Maintenance Manual November 1999 TABLE 1 1 TABLE 1 2 TABLE 2 1 TABLE 2 2 TABLE A 1 TABLE A 2 TABLE A 3 TABLE A 4 Tables Front Panel LEDs 3 Auto Termination Indication LEDs 6 AC Power Requirements 13 DC Power Requirements 14 Physical Specifications 43 AC Power Requirements 44 DC Power Requirements 44 Environmental Specifications 45 X Netra st D130 Installation and Maintenance Manual November 1999 Preface The Netra st D130 Installation and Maintenance Manual provides installation and configuration information and service procedures for the Netra st D130 storage enclosure These instructions are designed for an experienced system administrator How This Book Is Organized Chapter 1 describes the Netra st D130 storage enclosure Chapter 2 gives electrical information for the Netra st D130 storage enclosure Chapter 3 gives instructions for installing the Netra st D130 storage enclosure Chapter 4 gives the procedures for removing replacing or adding disk drives to the Netra st D130 storage enclosure Appendix A gives the system specifications for the Netra st D130 storage enclosure Using UNIX Commands This document may not contain inf
13. HE Vot re systeme est sous tension courant alternatif Un des symboles suivants sera peut tre utilis en fonction du type d interrupteur de votre syst me ARRET Votre syst me est hors tension courant alternatif VEILLEUSE L interrupteur Marche Veilleuse est en position Veilleuse Modification du mat riel Ne pas apporter de modification m canique ou lectrique au mat riel Sun Microsystems n est pas responsable de la conformit r glementaire d un produit Sun qui a t modifi Positionnement d un produit Sun Attention pour assurer le bon N fonctionnement de votre produit Sun et pour l emp cher de surchauffer il convient de ne pas obstruer ni recouvrir les ouvertures pr vues dans l appareil Un produit Sun ne doit jamais tre plac proximit d un radiateur ou d une source de chaleur au poste de travail s l ve selon la norme DIN Attention Le niveau de pression acoustique 45 635 section 1000 70 dB A ou moins Conformit SELV S curit les raccordements E S sont conformes aux normes SELV XXV Connexion du cordon d alimentation A xxvi Attention les produits Sun sont congus pour fonctionner avec des alimentations monophas es munies d un conducteur neutre mis la terre Pour carter les risques d lectrocution ne pas brancher de produit Sun dans un autre type d alimentation secteur En cas de doute quant au type d al
14. I daisy chain is a wide SCSI device install an external terminator on the SCSI OUT port on that device if it requires one Refer to the documentation that came with your wide SCSI device to determine if it needs an external terminator or not Chapter 29 m If the last device in the SCSI daisy chain is a narrow SCSI device install an external terminator on the SCSI OUT port on that device Host system 00 5 SCSI port Netra st D130 enclosure I 35 SCSI IN port SCSI OUT port Narrow SCSI device a SCSI IN port Y SCSI OUT port LE Er FIGURE 3 4 Daisy Chaining a Netra st D130 Storage Enclosure with a Narrow SCSI Device Connecting the Power Cable The procedures for connecting the power cable vary depending on whether you have the AC or the DC version of the Netra st D130 system m AC Version on page 31 m DC Version on page 31 30 Netra st D130 Installation and Maintenance Manual November 1999 AC Version Caution Ensure that the connection of multiple units to the supply circuit does not overload the supply overcurrent protection or supply wiring Refer to the Netra st D130 storage enclosure nameplate
15. Netra st D130 Installation and Maintenance Manual Sun microsystems THE NETWORK IS THE COMPUTER Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 USA 650 960 1300 Fax 650 969 9131 Part No 806 1489 10 November 1999 Revision A Send comments about this document to docfeedback sun com Copyright 1999 Sun Microsystems Inc 901 San Antonio Road Palo Alto California 94303 4900 U S A All rights reserved This product or document is protected by copyright and distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd For Netscape Communicator the following notice applies Copyright 1995 Netscape Communications Corporation All rights reserved Sun Sun Microsystems the Sun logo SunStore AnswerBook2 docs sun com Netra Solstice DiskSuite SunSwift and Solaris are trademarks registered trademarks or service marks of Sun Microsystems Inc in the U S and other countries All SPARC trademarks are used under license
16. RE 3 2 Netra st D130 Rear View AC Version 4 Determine if this Netra st D130 storage enclosure is at the beginning or the end of the SCSI chain m Tf this storage enclosure is at the end of the SCSI chain you are not connecting any other peripherals to your host system go to Connecting the Power Cable on page 30 m If this storage enclosure is at the beginning of the SCSI chain if you are going to daisy chain another Netra st D130 storage enclosure or peripheral off of this one keep the following things in mind You cannot daisy chain more than two Netra st D130 storage enclosures together You must verify that the SCSI IDs assigned to the disk drives in the second Netra st D130 storage enclosure or other peripheral are not already being used anywhere else in the daisy chain Refer to To Set the SCSI IDs for the Drives on page 27 for the SCSI IDs used for the disk drives in Netra st D130 storage enclosures Refer to the Solaris Handbook for Sun Peripherals available in the Solaris AnswerBook online documentation for information on how to determine which SCSI target IDs are available for your system 28 Netra st D130 Installation and Maintenance Manual November 1999 Keep in mind that if you connected the SCSI cable to the on board UltraSCSI port on your host system you must verify that the SCSI IDs assigned to the disk drives in the second Netra st D130 storage enclosure or peripheral are not already being used by an
17. RE 3 2 for the location of the power switch Note that when you release the power switch it settles into the center neutral position and the power remains on Reboot using the boot r command on your host system so that it recognizes the Netra st D130 storage enclosure Verify that the storage enclosure is running properly Refer to Chapter 1 Netra st D130 Storage Enclosure Overview for descriptions of the LEDs at the front and back of the Netra st D130 storage enclosure and what each LED indicates Chapter 33 34 To Power Off the Storage Enclosure Caution Before turning off the system power exit from the operating system Failure to do so may cause data loss If necessary notify users that the system is going down Back up system files and data if necessary Halt the operating system Press the power system switch on the storage enclosure to the standby position Verify that the System Power LED is off Disconnect the power cable from the power connector at the rear of the storage enclosure Caution Even with the power switch in the standby position power remains connected to the enclosure and potentially dangerous voltages is present in the power supply You must unplug the power cable to completely remove power to the enclosure Netra st D130 Installation and Maintenance Manual November 1999 CHAPTER 4 Adding Removing and Replacing Disk Drives This chapter gi
18. Sound power Operating 6 0B in accordance with ISO 9296 Idle 6 0B in accordance with ISO 9296 Earthquake Location NEBS requirements for earthquake zone 4 Note If you plan to operate the controller module at altitudes between 1000m and 3000m 3280 ft and 9850 ft you must lower the environmental temperature 3 37 1 7 F for every 1000m 3280 ft above sea level Appendix 45 46 Netra st D130 Installation and Maintenance Manual November 1999 Index A AC version connecting power cables 31 power requirements 13 44 power supply 9 airflow requirements 10 Auto Termination Indication LED 6 B back panel LEDs 6 C connecting DC grounding cable 31 power cables 30 SCSI cables 28 cooling system 9 D DC grounding cable connecting 31 DC input power cable assembling 16 DC version assembling the DC input power cable 16 connecting power cables 31 connection materials 16 DC supply and ground conductor 15 overcurrent protection 15 power requirements 14 44 power supply 9 Declaration of Conformity xix description 1 Disk Drive LED 4 disk drives adding 36 description 11 naming conventions 37 removing 39 replacing 41 software configuration procedures 37 E electrical specifications 44 environmental specifications 45 F foam fillers 12 front door 2 front panel LEDs 3 H hardware requirements 25 47 specifications electrical 44 environmental 45
19. achgerecht verlegte geerdete Steckdose an Achtung Trennen Sie alle Stromkabel um die gesamte Stromzufuhr zu diesem Ger t zu unterbrechen Achtung Netra st D130 Einheiten wurden f r die Stromversorgung mit Wechsel oder Gleichstrom entwickelt Die Stromversorgung h ngt vom mitgeliefertem Netzteil ab Die Einheiten die mit Gleichstrom betrieben werden werden mit einem 48V Stecker geliefert um dem Kunden den Anschluf an die Gleichstromquelle zu erm glichen Schliefsen Sie Gleichstromeinheiten ausschlie lich an Gleichstromquellen an Die folgende Warnung gilt nur fiir Ger te mit Wartezustand Netzschalter A Achtung Der Ein Aus Schalter dieses Ger ts schaltet nur auf Wartezustand Stand By Modus Um die Stromzufuhr zum Ger t vollst ndig zu unterbrechen miissen Sie das Netzkabel von der Steckdose abziehen Schliefsen Sie den Stecker des Netzkabels an eine in der N he befindliche frei zug ngliche geerdete Netzsteckdose an Schliefsen Sie das Netzkabel nicht an wenn das Netzteil aus der Systemeinheit entfernt wurde Geh useabdeckung A Achtung Bei Betrieb des Systems ohne obere Abdeckung besteht die Gefahr von Stromschlag und Systemsch den Einhaltung der Richtlinien f r Laser Sun Produkte die mit Laser Technologie arbeiten entsprechen den Anforderungen der Laser Klasse 1 Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 Conformit aux n
20. asonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded Cables Connections between the workstation and peripherals must be made using shielded cables to comply with FCC radio frequency emission limits Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment FCC Class B Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not instal
21. auf den Ger ten angebrachten Warnhinweise und Anweisungen m Vergewissern Sie sich da Spannung und Frequenz Ihrer Stromquelle mit der Spannung und Frequenz bereinstimmen die auf dem Etikett mit den elektrischen Nennwerten des Ger ts angegeben sind m Stecken Sie auf keinen Fall irgendwelche Gegenst nde in Offnungen in den Ger ten Leitf hige Gegenst nde k nnten aufgrund der m glicherweise vorliegenden gef hrlichen Spannungen einen Kurzschluf verursachen der einen Brand Stromschlag oder Ger teschaden herbeif hren kann Symbole Die Symbole in diesem Handbuch haben folgende Bedeutung Achtung Gefahr von Verletzung und Ger teschaden Befolgen Sie die Anweisungen Achtung Hohe Temperatur Nicht ber hren da Verletzungsgefahr durch hei e Oberfl che besteht Anweisungen befolgen um Stromschl ge und Achtung Gef hrliche Spannungen Verletzungen zu vermeiden Ein Setzt das System unter Wechselstrom Je nach Netzschaltertyp an Ihrem Ger t kann eines der folgenden Symbole benutzt werden Aus Unterbricht die Wechselstromzufuhr zum Ger t Wartezustand Stand by Position Der Ein Wartezustand Schalter steht auf Wartezustand nderungen an Sun Ger ten Nehmen Sie keine mechanischen oder elektrischen Anderungen an den Ger ten vor Sun Microsystems bernimmt bei einem Sun Produkt das ge ndert wurde keine Verantwortung f r die Einhaltung beh rdliche
22. ca nunca objetos de ning n tipo a trav s de los orificios del equipo Pueden haber voltajes peligrosos Los objetos extra os conductores de la electricidad pueden producir cortocircuitos que provoquen un incendio descargas el ctricas o da os en el equipo S mbolos En este libro aparecen los siguientes s mbolos personales y da os al equipo Siga las instrucciones Precauci n Existe el riesgo de lesiones contacto Las superficies est n calientes y Precauci n Superficie caliente Evite el pueden causar dafios personales si se tocan Precauci n Voltaje peligroso presente Para reducir el riesgo de descarga y da os para la salud siga las instrucciones Encendido Aplica la alimentaci n de CA al sistema Seg n el tipo de interruptor de encendido que su equipo tenga es posible que se utilice uno de los siguientes s mbolos Apagado Elimina la alimentaci n de CA del sistema En espera El interruptor de Encendido En espera se ha colocado en la posici n de En espera Modificaciones en el equipo No realice modificaciones de tipo mec nico o el ctrico en el equipo Sun Microsystems no se hace responsable del cumplimiento de las normativas de seguridad en los equipos Sun modificados Ubicaci n de un producto Sun funcionamiento de su producto Sun y para protegerlo de sobrecalentamien tos no deben obstruirse o taparse las rejillas del equipo Los productos Su
23. ck or cover the openings AN of your Sun product Never place a Sun product near a radiator or heat register Failure to follow these guidelines can cause overheating and affect the reliability of your Sun product level defined in DIN 45 635 Part 1000 must be Caution workplace dependent noise 70Db A or less SELV Compliance Safety status of I O connections comply to SELV requirements xxi Power Cord Connection A A gt xxii Netra st D130 Installation and Maintenance Manual November 1999 Caution Sun products are designed to work with single phase power systems having a grounded neutral conductor To reduce the risk of electric shock do not plug Sun products into any other type of power system Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building Caution Not all power cords have the same current ratings Household extension cords do not have overload protection and are not meant for use with computer systems Do not use household extension cords with your Sun product Caution The AC version of your Sun product is shipped with a grounding type three wire power cord To reduce the risk of electric shock always plug the cord into a grounded power outlet Caution In order to remove all power from this unit disconnect all power cords Caution Netra st D130 units are designed to work with
24. ck unit 1U 13 Ibs 18 Ibs 43 Electrical Specifications TABLE A 2 AC Power Requirements Electrical Element Requirement Voltage 100 VAC to 240 VAC nominal Frequency 47 63 Hz Input current lt 2 0 amps Q 100 VAC 150 W Max surge current 100 amp peaks TABLE A 3 DC Power Requirements Electrical Element Requirement Voltage 48 VDC Input current lt 4 0 amps 40 VDC 150 W Max input surge current 20 amps peaks 44 Netra st D130 Installation and Maintenance Manual November 1999 Environmental Specifications TABLE A 4 Environmental Specifications Climate Control Location Minimum to Maximum Range Temperature dry bulb Operating 0 C to 40 C 32 F to 104 F Storage 25 C to 65 C 13 F to 149 F Transit 25 C to 65 C 13 F to 149 F Short term 96 consecutive hrs Operating 5 C to 55 C 23 F to 131 F Nonoperating 40 C to 70 C 40 F to 158 F Temperature derating max Operating 3 3 C per 1000m 1 7 F per 1000 ft above sea level Relative humidity non Operating 5 to 90 condensing Storage 5 to 95 Transit 5 to 95 Short term 96 consecutive hrs Operating 5 to 90 Non operating 5 to 95 Altitude based on drives Operating Om to 3000m 0 ft to 10 000 ft above sea level Storage Om to 12 000m 0 ft to 40 000 ft above sea level Transit Om to 12 000m 0 ft to 40 000 ft above sea level Heat dissipation maximum Operating 150 watts 512 BTU per hour
25. duct Safety Precautions For your protection observe the following safety precautions when setting up your equipment m Follow all cautions and instructions marked on the equipment m Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment s electrical rating label m Never push objects of any kind through openings in the equipment Dangerous voltages may be present Conductive foreign objects could produce a short circuit that could cause fire electric shock or damage to your equipment Symbols The following symbols may appear in this book equipment damage Follow the instructions Caution There is risk of personal injury and Caution Hot surface Avoid contact Surfaces are hot and may cause personal injury if touched reduce the risk of electric shock and danger to personal health follow the instructions Caution Hazardous voltages are present To On Applies AC power to the system Depending on the type of power switch your device has one of the following symbols may be used Q Off Removes AC power from the system Standby The On Standby switch is in the standby position Modifications to Equipment Do not make mechanical or electrical modifications to the equipment Sun Microsystems is not responsible for regulatory compliance of a modified Sun product Placement of a Sun Product Caution Do not blo
26. e 25 m Preparing for Installation on page 26 m Installing the Netra st D130 Storage Enclosure on page 27 m Powering On and Off on page 33 Hardware Requirements The following hardware is included with every Netra st D130 storage enclosure UltraSCSI cables m Power connections depending on the type of storage enclosure AC version one AC power a DC version four DC connectors are provided to form input cables for connecting to DC sources with a 10 amp breaker for each source two DC connectors for input cables and two spare DC connectors Four strain relief housings two for the input cables and two spares and one cage clamp operating lever are also included 25 You must also have the following hardware at your site to successfully install your Netra st D130 storage enclosure m A host system with a single ended UltraSCSI on board port or m A host adapter board installed in the host system For Netra systems use either of the following boards a SunSwift 10 100 Ethernet UltraSCSI PCI adapter Model X1032A a Dual channel single ended UltraSCSI PCI adapter Model X6540A For UltraSCSI functionality the host or host adapter to which you connect your Netra st D130 storage enclosure must be capable of UltraSCSI speeds You can connect a Netra st D130 storage enclosure to a wide or narrow SCSI capable host adapter but in such a case the enclosure performs at a lower speed Preparing for Installation
27. e Netra st D130 storage enclosure in the daisy chain Off On N A 6 Netra st D130 Installation and Maintenance Manual November 1999 Note UltraSCSI devices such as the Netra st D130 storage enclosure at the end of a daisy chain do not require a terminator but some wide SCSI devices at the end of a daisy chain do require a terminator Refer to the documentation that came with your wide SCSI device to determine if it needs a terminator or not Narrow SCSI devices at the end of a daisy chain always require a terminator Host system Gi Netra st D130 enclosure a 00 le B ED Netra st 0130 enclosure or Wide SCSI device mm GN b m 29 ORAR No Auto Termination Indication LEDs lit Both High and Low Auto Termination Indication LEDs lit FIGURE 1 8 Auto Termination Indication LEDs Lit in UltraSCSI or Wide SCSI Daisy Chain Chapter 7 Host system 0 0 Netra st D130 enclosure 3 Narrow SCSI device High Auto Termination Indication LED lit 00 5 o je LI j
28. e may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation European Union EC This equipment complies with the following requirements of the EMC Directive 89 336 EEC EN55022 CISPR22 1985 Class A EN50082 1 IEC801 2 1991 4 kV Direct 8 kV Air IEC801 3 1984 3 V m IEC801 4 1988 1 0 kV Power Lines 0 5 kV Signal Lines EN61000 3 2 TEC1000 3 2 1994 Pass Safety This equipment complies with the following requirements of the Low Voltage Directive 73 23 EEC EC Type Examination Certificates EN60950 IEC950 1993 EN60950 Evaluated to all CB Scheme Country Deviations Supplementary Information This product was tested and complies with all the requirements for the CE Mark when connected to a Sun workstation or server S S Dennis P Symanski DATE John Shades DATE Manager Product Compliance Quality Assurance Manager Sun Microsystems Inc Sun Microsystems Scotland Limited 901 San Antonio Road M S UMPK15 102 Springfield Linlithgow Palo Alto CA 94303 USA West Lothian EH49 7LR Scotland United Kingdom Tel 650 786 3255 Tel 0506 670000 Fax 650 786 3723 Fax 0506 760011 xix xx Netra st D130 Installation and Maintenance Manual November 1999 Safety Agency Compliance Statements Read this section before beginning any procedure The following text provides safety precautions to follow when installing a Sun Microsystems pro
29. e the SCSI ID switch to the setting that you want to use to set the SCSI IDs for the disk drives in the Netra st D130 storage enclosure Verify that the SCSI IDs that you want to use for the drives in your Netra st D130 storage enclosure are not being used already by your host system or by other peripherals connected to your host system If you are daisy chaining two Netra st D130 storage enclosures together you must set the enclosures to two different SCSI ID settings Installing the Netra st D130 Storage Enclosure Mounting the Storage Enclosure in a Rack Refer to the Netra st D130 Product Notes for instructions on mounting the Netra st D130 storage enclosure into a rack Chapter 27 Connecting the SCSI Cables V To Connect the SCSI Cables 1 Verify that the host system has been powered down Refer to To Prepare the Host System on page 26 for more information 2 Get the 2 meter SCSI cable from the ship kit and connect one end of the SCSI cable to your host system You can connect the SCSI cable to an UltraSCSI PCI host adaptor or the on board SCSI port as long as it s an UltraSCSI port Refer to the documentation that came with your host system for the location of the UltraSCSI port on the host system 3 Connect the other end of the SCSI cable to the SCSI IN port at the rear of the Netra st D130 storage enclosure o O O SCSI IN port No guo e mmm O SOSIN pont Power switch FIGU
30. ected to the DC power source through the circuit breakers The first DC input power cable should be connected to DC power source A and the second DC input power cable should be connected to DC power source B Refer to Assembling the DC Input Power Cable on page 16 if you have not already assembled the DC input cables 8 Connect one DC input power cable to a DC connector at the rear of the Netra st D130 storage enclosure FIGURE 3 7 Connecting the DC Input Power Cable to the DC Connector Repeat Step 8 connecting the second DC input power cable to the other DC connector at the rear of the enclosure Refer to FIGURE 3 6 for the locations of the DC connectors on the DC power supplies at the rear of the enclosure 10 Turn on the circuit breakers to provide power to the enclosure To disconnect the DC input power cable from the DC connector squeeze the two tabs on the sides of the DC input power cable and gently disconnect the DC input power cable from the DC power supply 32 Netra st D130 Installation and Maintenance Manual November 1999 FIGURE 3 8 Disconnecting the DC Input Power Cable from the DC Connector Powering On and Off To Power On the Storage Enclosure Press the power switch at the rear of the storage enclosure to the On 1 position See FIGU
31. ed personnel only and has access controlled by some sort of locking mechanism such as a key lock or an access card system Overcurrent Protection Requirements m Overcurrent protection devices must be provided as part of each equipment rack m Circuit breakers must be located between the DC power source and the Netra st D130 storage enclosure You should use two 10 amp double pole fast trip DC rated circuit breakers for each power supply Note Overcurrent protection devices must meet applicable national and local electrical safety codes and be approved for the intended application DC Supply and Ground Conductor Requirements m Suitable conductor material copper only m Power supply connections through the input connector 12 AWG between the Netra st D130 and the circuit breaker There are three conductors 48V Ground connection to the power supply 48V Return m System ground conductor 8 AWG to be connected to the chassis m Cable insulation rating minimum of 75C low smoke fume LSF flame retardant m Cable type to be one of the following a UL style 1028 or other UL 1581 VW 1 compliant equivalent IEEE 383 compliant IEEE 1202 1991 compliant m Branch circuit cable insulation color per applicable National Electrical Codes m Grounding cable insulation color green yellow Chapter 15 Assembling the DC Input Power Cable Follow these instructions to assemble the DC input power cable which w
32. either AC or DC power depending on the power pack included with the product Units designed to work with DC power are shipped with a connector to be used with a customer supplied 48V power cord for the customer to connect to the DC power source Always connect DC powered units to a DC power source only The following caution applies only to devices with a Standby power switch A Caution The power switch of this product functions as a standby type device only The power cord serves as the primary disconnect device for the system Be sure to plug the power cord into a grounded power outlet that is nearby the system and is readily accessible Do not connect the power cord when the power supply has been removed from the system chassis System Unit Cover A Caution Do not operate Sun products without the top cover in place Failure to take this precaution may result in personal injury and system damage Laser Compliance Notice Sun products that use laser technology comply with Class 1 laser requirements Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 Einhaltung sicherheitsbeh rdlicher Vorschriften Auf dieser Seite werden Sicherheitsrichtlinien beschrieben die bei der Installation von Sun Produkten zu beachten sind Sicherheitsvorkehrungen Treffen Sie zu Ihrem eigenen Schutz die folgenden Sicherheitsvorkehrungen wenn Sie Ihr Ger t installieren m Beachten Sie alle
33. enci s Sun reconnait les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun CETTE PUBLICATION EST FOURNIE EN L ETAT ET AUCUNE GARANTIE EXPRESSE OU IMPLICITE N EST ACCORDEE Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS CE DENI DE GARANTIE NE S APPLIQUERAIT PAS DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU eed Adobe PostScript Contents Preface xi Regulatory Compliance Statements xv Declaration of Conformity xix Safety Agency Compliance Statements xxi Netra st D130 Storage Enclosure Overview 1 Components at the Front of the Enclosure 2 Front Panel 2 Front Panel LEDs 3 Components at the Back of the Enclosure 4 Power Switch 5 SCSI ID Switch 5 Back Panel LEDs 6 Internal Components 8 Power Supply 8 Cooling System 9 Disk Drives 11 Foam Fillers 12 Netra st D130 Software Considerations 12 2 Electrical Requirements and Cable Assembly 13 AC Source Site Requirements 13 DC So
34. ill be used to connect the DC power supply in your Netra st D130 storage enclosure to the DC power source Required Connection Materials The following DC connection materials are provided with every Netra st D130 storage enclosure for connection to the 48V DC power source m Four WAGO DC connectors two DC connectors for input cables and two spare DC connectors m Four WAGO DC strain relief housings two strain relief housings for input cables and two spare strain relief housings One cage clamp operating lever m Four tie wraps The following figures show the DC connector strain relief housing and cage clamp operating lever You can order additional DC connection materials through Sun Microsystems X949A FIGURE 2 1 DC Connector 16 Netra st D130 Installation and Maintenance Manual November 1999 FIGURE 2 2 Strain Relief Housing FIGURE 2 3 Cage Clamp Operating Lever The following figure shows the power connector on the DC power supply 1 2 3 48V GND 48V RTN C E FIGURE 2 4 Power Connector on the DC Power Supply Chapter 17 To Assemble the DC Input Power Cable Turn off power to the DC power source through the circuit breakers Caution Do not proceed with these instructions until you have turned off the power to the DC power source through the circuit breakers Get a DC connector from the ship kit Locate the
35. imentation lectrique du local veuillez vous adresser au directeur de l exploitation ou un lectricien qualifi Attention tous les cordons d alimentation n ont pas forc ment la m me puissance nominale en mati re de courant Les rallonges d usage domestique n offrent pas de protection contre les surcharges et ne sont pas pr vues pour les syst mes d ordinateurs Ne pas utiliser de rallonge d usage domestique avec votre produit Sun Attention La version pour courant alternatif de votre produit Sun a t livr e quip e d un cordon d alimentation trois fils avec prise de terre Pour carter tout risque d lectrocution branchez toujours ce cordon dans une prise mise la terre Attention Pour mettre le syst me hors tension il est imp ratif de d brancher tous les cordons d alimentation con ues pour fonctionner avec une alimentation en courant alternatif ou en courant continu selon le bloc d alimentation inclus avec le produit Les unit s concues pour fonctionner en courant continu sont livr es avec un connecteur pour cordon d alimentation 48 V non fourni que le client utilisera pour connecter l unit la source d alimentation CC Connectez toujours les unit s aliment es en courant continu une source d alimentation CC l exclusion de toute autre Attention les unit s Netra st D130 sont L avertissement suivant s applique uniquement aux systemes quip
36. irements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du Reglement sur le mat riel brouilleur du Canada VCCI B CDT Z2AANCCI H ISDUT I FAA VCCI D RNHBDI YIAF VaAVBLOTFTV BA 77 AA TR MERC ald ENE EJ OFRECES 4 7 7 a KATI CORE ERE TEN TD CE xs mE 24250 HUET TOBA BE ANUIES SKID BRANSZTEMHBVET 7373 B VCCI TDT 73 B VCCI DER RHSZI IAF Y a BLOAT a Bild 73 TS FDHENAYLET CORAL RUE ERE EI VCCT 225 7 27A gt ATI CORB KERHTENMTSZLEHNELTUEER DRAENTFTIAPTLEISTZERGHEL TEN SNS VERMEER FE 29020005069 BANNE MED TEL VB NEUTS ESM BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label xvi Netra st D130 Installation and Maintenance Manual November 1999 BERE ER HUS EUER dE GUERRE B TE DANA ERE SKA lt xvii xviii Netra st D130 Installation and Maintenance Manual November 1999 Declaration of Conformity Agency Model Number CYT1A AC version CYT1D DC version Product Name Netra st D130 This product has been tested and complies with the following rules and requirements EMC USA FCC Class A This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This devic
37. led and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help Shielded Cables Connections between the workstation and peripherals must be made using shielded cables in order to maintain compliance with FCC radio frequency emission limits Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment xv DOC Class A Notice Avis DOC Classe A This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du Reglement sur le mat riel brouilleur du Canada DOC Class B Notice Avis DOC Classe B This Class B digital apparatus meets all requ
38. losure AC or DC input will continue to flow to the power supply until you unplug the power cable from the electrical outlet SCSI ID Switch The SCSI ID switch sets the SCSI IDs for the disk drives SCSI IDs set to SCSI IDs set to 2 3 and 4 from 10 11 and 12 left to right from left to right 1 0 FIGURE 1 6 SCSI ID Switch Chapter 5 Back Panel LEDs Auto Termination Indication LEDs System Power LED D a 2 24 o FIGURE 1 7 Back Panel LEDs System Power and System Summary Fault LEDs The System Power and System Summary Fault LEDs give the same diagnostic information as the System Power and System Summary Fault LEDs at the front of the enclosure Refer to TABLE 1 1 on page 3 for more information Auto Termination Indication LEDs The Auto Termination Indication LEDs indicate if the Netra st D130 storage enclosure is part of an UltraSCSI wide SCSI or narrow SCSI daisy chain It also indicates its position in the daisy chain TABLE 1 2 Auto Termination Indication LEDs High Low Meaning Off Off The Netra st D130 storage enclosure is the first device in the UltraSCSI or wide SCSI daisy chain another device follows it On On The Netra st D130 storage enclosure is the last or only device in the UItraSCSI or wide SCSI daisy chain On Off A narrow SCSI device follows th
39. maximum cooling Verify that you have either a replacement drive or a foam filler handy before removing a disk drive from the enclosure unless you are returning a defective Netra st D130 storage enclosure Chapter 39 1 Ensure there is no activity to the drives If the Disk Drive LED for that disk drive is flashing green the drive is still active When the Disk Drive LED is lit solid green then the drive is no longer active and it is safe to remove it 2 Prepare the software environment to remove the drive See the documentation that came with your software for application specific instructions that you might need to perform before you can remove the disk drive 3 Remove the front panel by pressing the latches on both ends and pulling the panel away from the enclosure FIGURE 4 1 4 Unlatch the drive bracket handle to release it Push in the direction of the arrow to release the latch FIGURE 4 3 Removing and Replacing a Disk Drive 5 Pull the bracket handle out and swing it open 6 Continue to pivot the disk drive bracket handle against the chassis applying mild pressure until the drive disconnects 7 Slide the drive out 8 Determine if you are going to replace the disk drive immediately or not m If you are going to replace the disk drive immediately go to To Replace a Disk Drive on page 41 m If you are not going to replace the disk drive immediately determine if you are returning a defective Netra st D130
40. n nunca deben situarse cerca de radiadores o de fuentes de calor Precauci n Para asegurar la fiabilidad de 635 Parte 1000 se admite un nivel de presi n ac stica para puestos de trabajo m ximo de 70Db A Precauci n De acuerdo con la norma DIN 45 xxvii El estado de la seguridad de las conexiones de entrada salida cumple los requisitos de la normativa SELV Cumplimiento de la normativa SELV Conexi n del cable de alimentaci n el ctrica dise ados para trabajar en una red el ctrica monof sica con toma de tierra Para reducir el riesgo de descarga el ctrica no conecte los productos Sun a otro tipo de sistema de alimentaci n el ctrica P ngase en contacto con el responsable de mantenimiento o con un electricista cualificado si no est seguro del sistema de alimentaci n el ctrica del que se dispone en su edificio Precauci n Los productos Sun est n A alimentaci n el ctrica tienen la misma espera Precauci n Para cortar el suministro el ctrico de esta unidad desconecte todos los cables de alimentaci n Precauci n El dise o de las unidades Netra st D130 permite su funcionamiento con alimentaci n de CA o CC seg n el tipo de alimentaci n para el que est preparado su producto Las unidades destinadas a su funcionamiento con CC se entregan con un conector que debe usarse con un cable de alimentaci n de 48 V del cliente a fin de que este ltimo se pueda co
41. nectar a la fuente de alimentaci n de CC Conecte siempre las unidades preparadas para CC nicamente a fuentes de alimentaci n de CC La siguiente advertencia se aplica solamente a equipos con Precauci n No todos los cables de un interruptor de encendido que tenga una posici n En capacidad Los cables de tipo dom stico no est n provistos de protecciones contra sobrecargas y por tanto no son apropiados para su uso con computadores No utilice alargadores de tipo dom stico para conectar sus productos Sun producto Sun se proporciona un cable de alimentaci n con toma de tierra Para reducir el riesgo de descargas el ctricas con ctelo siempre a un enchufe con toma de tierra Precauci n Con la versi n para CA del Tapa de A Precauci n El interruptor de encendido de este producto funciona exclusivamente como un dispositivo de puesta en espera El enchufe de la fuente de alimentaci n est dise ado para ser el elemento primario de desconexi n del equipo El equipo debe instalarse cerca del enchufe de forma que este ltimo pueda ser f cil y r pidamente accesible No conecte el cable de alimentaci n cuando se ha retirado la fuente de alimentaci n del chasis del sistema la unidad del sistema Precauci n Es peligroso hacer funcionar los productos Sun sin la tapa superior colocada El hecho de no tener en cuenta esta precauci n puede ocasionar da os personales o perjudicar el funcionamien
42. ng Sun Documentation Online The docs sun web site enables you to access Sun technical documentation on the Web You can browse the docs sun archive or search for a specific book title or subject at http docs sun com Sun Welcomes Your Comments We are interested in improving our documentation and welcome your comments and suggestions You can email your comments to us at docfeedback sun com Please include the part number 806 1489 10 of your document in the subject line of your email xiii xiv Netra st D130 Installation and Maintenance Manual November 1999 Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class e Federal Communications Commission FCC USA Department of Communications DOC Canada Voluntary Control Council for Interference VCCI Japan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product FCC Class A Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide re
43. ormation on basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices See one or more of the following for this information m Solaris Handbook for Sun Peripherals m AnswerBook2 online documentation for the Solaris software environment xi m Other software documentation that you received with your system Typographic Conventions TABLE P 1 Typographic Conventions Typeface Meaning AaBbCc123 The names of commands files and directories on screen computer output AaBbCc123 What you type when contrasted with on screen computer output AaBbCc123 Book titles new words or terms words to be emphasized Command line variable replace with a real name or value xii Shell Prompts TABLE P 2 Shell Prompts Examples Edit your login file Use 15 a to list all files 9 You have mail SU Password Read Chapter 6 in the User s Guide These are called class options You must be superuser to do this To delete a file type rm filename Shell C shell C shell superuser Bourne shell and Korn shell Bourne shell and Korn shell superuser Netra st D130 Installation and Maintenance Manual November 1999 Prompt machine names machine names Related Documentation TABLE P 3 Related Documentation Application Title Part Number Late breaking information Netra st D130 Product Notes 806 1490 10 Accessi
44. ormes de s curit Ce texte traite des mesures de s curit qu il convient de prendre pour l installation d un produit Sun Microsystems Mesures de s curit Pour votre protection veuillez prendre les pr cautions suivantes pendant l installation du mat riel m Suivre tous les avertissements et toutes les instructions inscrites sur le mat riel m V rifier que la tension et la fr quence de la source d alimentation lectrique correspondent la tension et la fr quence indiqu es sur l tiquette de classification de l appareil m Ne jamais introduire d objets quels qu ils soient dans une des ouvertures de l appareil Vous pourriez vous trouver en pr sence de hautes tensions dangereuses Tout objet conducteur introduit de la sorte pourrait produire un court circuit qui entra nerait des flammes des risques d lectrocution ou des d g ts mat riels Symboles Vous trouverez ci dessous la signification des diff rents symboles utilis s Attention risques de blessures et de d g ts mat riels Veuillez suivre les instructions Attention surface temp rature lev e N Evitez le contact La temp rature des surfaces est lev e et leur contact peut provoquer des blessures corporelles Attention pr sence de tensions AN dangereuses Pour viter les risques d lectrocution et de danger pour la sant physique veuillez suivre les instructions MARC
45. physical 43 System Power LED 3 6 L System Summary Fault LED 3 6 LEDs Auto Termination Indication 6 back panel 6 Disk Drive 4 front panel 3 System Power 3 6 System Summary Fault 3 6 installing the enclosure 27 P physical specifications 43 power cables connecting 30 power supply AC version 9 DC version 9 power switch 5 powering off the enclosure 34 powering on the enclosure 33 preparing the host system 26 product description 1 R Regulatory Compliance Statements xv removing a disk drive 39 S Safety Agency Compliance Statements xxi SCSI cables connecting 28 SCSI ID switch 5 SCSI IDs setting 5 27 SCSI ports location 28 software considerations 12 Solaris device entry 37 source site requirements AC version 13 DC version 14 48 Netra st D130 Installation and Maintenance Manual November 1999
46. r Vorschriften Aufstellung von Sun Ger ten Sun Ger ts zu gew hrleisten und es vor berhitzung zu sch tzen d rfen die ffnungen im Ger t nicht blockiert oder verdeckt werden Sun Produkte sollten niemals in der N he von Heizk rpern oder Heizluftklappen aufgestellt werden Achtung Um den zuverl ssigen Betrieb Ihres Schalldruckpegel nach DIN 45 635 Teil 1000 Achtung Der arbeitsplatzbezogene betr gt 70Db A oder weniger Einhaltung der SELV Richtlinien Die Sicherung der I O Verbindungen entspricht den Anforderungen der SELV Spezifikation xxiii Anschlufs des Netzkabels A xxiv Netra st D130 Installation and Maintenance Manual November 1999 Achtung Sun Produkte sind f r den Betrieb an Einphasen Stromnetzen mit geerdetem Nulleiter vorgesehen Um die Stromschlaggefahr zu reduzieren schliefen Sie Sun Produkte nicht an andere Stromquellen an Ihr Betriebsleiter oder ein qualifizierter Elektriker kann Ihnen die Daten zur Stromversorgung in Ihrem Geb ude geben Achtung Nicht alle Netzkabel haben die gleichen Nennwerte Herk mmliche im Haushalt verwendete Verl ngerungskabel besitzen keinen berlastungsschutz und sind daher f r Computersysteme nicht geeignet Achtung Die Wechselstromversion Ihres Sun Ger tes wird mit einem dreiadrigen Netzkabel f r geerdete Netzsteckdosen geliefert Um die Gefahr eines Stromschlags zu reduzieren schliefen Sie das Kabel nur an eine f
47. r the new disk drive Make a note of which slot you choose for reference when you configure the software environment 3 Remove the foam filler Store the foam filler in a safe place for future use 4 Hold the locking handle open on the disk drive Push in the direction of the arrow to release the latch 36 Netra st D130 Installation and Maintenance Manual November 1999 FIGURE 4 2 Adding a Disk Drive Slide the replacement disk drive into the vacant slot Gently push the drive until the locking handle engages Close the locking handle completely using gentle downward pressure When the drive is firmly installed it will spin up automatically See SCSI ID Switch on page 5 to find the SCSI ID of the drive you added Performing the Software Configuration Procedures When you add a disk drive you must create a new device entry for the drive in the devices dev dsk and dev rdsk hierarchies The new drive is assigned a name associated with the slot in the Netra st D130 storage enclosure into which the drive was installed To Create a New Solaris Device Entry The naming convention for disks attached to a host adapter is cwtxdysz where w corresponds to the controller in your system x corresponds to the SCSI target of the disk y is the logical unit for the disk drive always 0 z is the slice or partition on the disk Chapter 37 For example if the Netra st D130 storage enclosure is connected to a
48. s d un interrupteur VEILLEUSE ce produit fonctionne comme un dispositif de mise en veille uniquement C est la prise d alimentation qui sert mettre le produit hors tension Veillez donc installer le produit proximit d une prise murale facilement accessible Ne connectez pas la prise d alimentation lorsque le ch ssis du systeme n est plus aliment Attention le commutateur d alimentation de Couvercle fonctionner un produit Sun sans le couvercle en place Si l on n glige cette pr caution on encourt des risques de blessures corporelles et de d g ts mat riels Attention il est dangereux de faire Conformit aux certifications Laser Les produits Sun qui font appel aux technologies lasers sont conformes aux normes de la classe 1 en la mati re Netra st D130 Installation and Maintenance Manual November 1999 Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 Normativas de seguridad El siguiente texto incluye las medidas de seguridad que se deben seguir cuando se instale alg n producto de Sun Microsystems Precauciones de seguridad Para su protecci n observe las siguientes medidas de seguridad cuando manipule su equipo m Siga todas los avisos e instrucciones marcados en el equipo m Aseg rese de que el voltaje y la frecuencia de la red el ctrica concuerdan con las descritas en las etiquetas de especificaciones el ctricas del equipo m No introduz
49. slots The foam fillers are air baffles They allow the storage enclosure to maintain maximum cooling If any slot does not contain a disk drive you must fill the slot with a foam filler so the unit will cool properly Netra st D130 Software Considerations The Netra st D130 storage enclosure can be used as additional disk storage for an existing host system it can also be used in conjunction with Veritas VxVm or the Solstice DiskSuite software in a RAID based system 12 Netra st D130 Installation and Maintenance Manual November 1999 CHAPTER 2 Electrical Requirements and Cable Assembly This chapter provides electrical information for both the AC and DC powered versions of the Netra st D130 storage enclosure This chapter is organized as follows AC Source Site Requirements on page 13 DC Source Site Requirements on page 14 Assembling the DC Input Power Cable on page 16 Isolating the Chassis Ground Connection on page 23 AC Source Site Requirements TABLE 2 1 Power Requirements Electrical Element Requirement Voltage 100 VAC to 240 VAC nominal Frequency 47 63 Hz Input current lt 2 0 amps Q 100 VAC 150 W Max surge current 100 amp peaks Overcurrent protection devices must be provided as part of each host equipment rack Circuit breakers are located between the AC source and the Netra st D130 storage enclosure m Circuit breakers must not trip when presented with inr
50. three wires coming from the DC power source that will be used in the connection to your unit m 48V m GND Ground m 48V Return Strip 5 16 of an inch 8 mm of insulation from each of the wires coming from the DC power source Do not strip more than 5 16 of an inch 8 mm from each wire Doing so will leave uninsulated wire exposed from the DC connector after the assembly is complete k 5 16 in 8 mm FIGURE 2 5 Stripping the Insulation From the Wire Insert the tip of the cage clamp operating lever into the rectangular hole directly above the hole in the DC connector where you want to insert the first wire and press down on the cage clamp operating lever This opens the cage clamp for this section of the DC connector Netra st D130 Installation and Maintenance Manual November 1999 Top of connector FIGURE 2 6 Opening the DC Connector Cage Clamp Using the Cage Clamp Operating Lever You can also open the DC connector cage clamp by inserting a small flat blade screwdriver into the rectangular hole directly above the hole in the DC connector where you want to insert the first wire and pressing down on the screwdriver Chapter 19 Top of connector FIGURE 2 7 Opening the DC Connector Cage Clamp Using a Screwdriver 6 Feed the exposed section of the appropriate wire into that hole in the DC connector FIGURE 2 8 shows which wires should be inserted into each hole in the DC connector Blue from 48V Ret
51. to del equipo Aviso de cumplimiento con requisitos de l ser Los productos Sun que utilizan la tecnolog a de l ser cumplen con los requisitos de l ser de Clase 1 xxviii Netra st D130 Installation and Maintenance Manual November 1999 Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser KLasse 1 GOST R Certification Mark giy xxix xxx Netra st D130 Installation and Maintenance Manual November 1999 CHAPTER 1 Netra st D130 Storage Enclosure Overview This chapter describes the Netra st D130 storage enclosure hardware except for the hard drives For information on the drives refer to the documents that you received with them The Netra st D130 disk unit is a single ended UltraSCSI unit that is 1 73 inches or 1U in height The thinness of the unit enables you to stack up to 40 units in a single 72 inch tall rack The Netra st D130 storage enclosure has a single power supply available in AC or DC versions and up to three hot pluggable single ended UltraSCSI hard disk drives This chapter is organized as follows m Components at the Front of the Enclosure on page 2 m Components at the Back of the Enclosure on page 4 m Internal Components on page 8 FIGURE 1 1 Netra st D130 Storage Enclosure Components at the Front of the Enclosure Front Panel The front panel can be removed to allow access to the hard disk drives The Netra st D130 storage enclosure can accept up
52. tribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des systemes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd La notice suivante est applicable Netscape Communicator Copyright 1995 Netscape Communications Corporation All rights reserved Sun Sun Microsystems le logo Sun SunStore AnswerBook2 docs sun com Netra Solstice DiskSuite SunSwift et Solaris sont des marques de fabrique ou des marques d pos es ou marques de service de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et lic
53. urce Site Requirements 14 Overcurrent Protection Requirements 15 DC Supply and Ground Conductor Requirements 15 Assembling the DC Input Power Cable 16 Required Connection Materials 16 Isolating the Chassis Ground Connection 23 3 Installing the Netra st D130 Storage Enclosure 25 Hardware Requirements 25 Preparing for Installation 26 v ToPrepare the Host System 26 ToSetthe SCSI IDs for the Drives 27 Installing the Netra st D130 Storage Enclosure 27 Mounting the Storage Enclosure in a Rack 27 Connecting the SCSI Cables 28 Connecting the Power Cable 30 Powering On and Off 33 v ToPowerOntheStorage Enclosure 33 v To Power Off the Storage Enclosure 34 4 Adding Removing and Replacing Disk Drives 35 Adding a Disk Drive 35 v To Adda Disk Drive 36 Performing the Software Configuration Procedures 37 Removing and Replacing a Disk Drive 39 iv Netra st D130 Installation and Maintenance Manual November 1999 v To Remove a Disk Drive 39 v ToReplacea Disk Drive 41 A System Specifications 43 vi Netra st D130 Installation and Maintenance Manual November 1999 GURE 1 1 GURE 1 2 GURE 1 3 GURE 1 4 GURE 1 5 GURE 1 6 GURE 1 7 GURE 1 8 GURE 1 9 GURE 1 10 GURE 1 11 GURE 1 12 GURE 1 13 GURE 1 14 GURE 2 1 GURE 2 2 GURE 2 3 GURE 2 4 GURE 2 5 GURE 2 6 Figures Netra st D130 Storage Enclosure 1 Removing the Front Panel 2 Front Panel LEDs 3 Netra st 0130 Rear View 4
54. urn source Green yellow from ground source Top of connector White from 48V source OO SE FIGURE 2 8 Assembling the DC Input Power Cable 7 Repeat Step 5 and Step 6 for the other two wires to complete the assembly of the DC input power cable 8 Repeat Step 3 through Step 7 to create a second DC input power cable The first DC input power cable should be connected to DC power source A and the second DC input power cable should be connected to DC power source B 20 Netra st D130 Installation and Maintenance Manual November 1999 If you need to remove a wire from the DC connector insert the cage clamp operating lever or a small screwdriver into the slot directly above the wire and press down FIGURE 2 6 and FIGURE 2 7 V To Install the Strain Relief Housings 1 Take the DC connector and insert the bottom portion of the strain relief housing into the notch on the DC connector until it snaps into place Make sure the strain relief housing snaps into place on the DC connector you will not be able to complete the assembly correctly if the strain relief housing is not secure Sm f FIGURE 29 Inserting the Bottom Portion of the Strain Relief Housing 2 Route the three wires coming from the DC power source through the opening at the end of the bottom portion of the strain relief housing Chapter 21
55. ush current of 100 amps lasting 5 ms Note Overcurrent protection devices must meet applicable national and local electrical safety codes and be approved for the intended application You can disconnect the power for servicing in any of the following ways m Disconnect the power cord from the connector on the AC power supply at the rear of the enclosure m Turn off the circuit breakers in the rack where the enclosure is mounted m Disconnect the main plug from the AC source Ensure that all methods of disconnecting the power remain accessible after installation Caution External filtering and surge suppression devices may be required on the power feeds where branch circuit electromagnetic characteristics are unknown DC Source Site Requirements TABLE 2 2 DC Power Requirements Electrical Element Requirement Voltage 48 VDC Input current lt 4 0 amps 40 VDC 150 W Max input surge current 20 amps peaks m Electrically isolated from any AC source m Reliably connected to earth the battery room positive bus is connected to ground m Capable of providing up to 200 watts of continuous power per feed pair 14 Netra st D130 Installation and Maintenance Manual November 1999 Note The DC version of the Netra st D130 storage enclosure must be installed in a restricted access location Per the intent of the National Electrical Code a restricted access location is an area intended for qualified or train
56. ve No disk drive is present in that slot or the disk drive has failed No action is necessary No action is necessary If a disk drive is present in that slot and the Disk Drive LED is unlit then you must replace the disk drive See Removing and Replacing a Disk Drive on page 39 Note If a disk drive is under an unusually heavy load for example if the drive is being reformatted the Disk Drive LED may be unlit for a long period of time even though the drive has not failed You should see a message in your console window telling you that the disk drive is offline if the disk drive has truly failed Components at the Back of the Enclosure Power connector Power switch LO Smet SCSI IN port SCSI ID switch FIGURE 1 4 Netra st D130 Rear View 4 Netra st D130 Installation and Maintenance Manual November 1999 du SCSI OUT port Back panel LEDs Power Switch The Netra st D130 storage enclosure has one rocker power switch to control the power supply On Neutral Standby FIGURE 1 5 Power Switch m On The power supply provides power to the enclosure m Neutral When the switch is released from the ON position the switch settles into the Neutral position and the power supplies remain on m Standby The power supply does not provide power to the enclosure Caution Placing the power switch in the Standby position does not completely remove power to the enc
57. ves hardware and software instructions for adding removing and replacing disk drives in a Netra st D130 storage enclosure This chapter is organized as follows m Adding a Disk Drive on page 35 m Removing and Replacing a Disk Drive on page 39 Adding a Disk Drive This section contains information on how to configure your storage enclosure when you add a disk drive while the power is on and the operating system is running This is called hot plugging The way you add a disk drive depends on the software application you are using For each application decide where to install the new disk drive add the drive and then reconfigure the operating environment Each application is different In all cases you must select a slot physically install the disk drive and configure the Solaris environment to recognize the drive You must then configure your application to accept the new disk drive Caution These procedures should be performed only by a qualified system administrator Performing hot plug operations on an active disk drive can result in data loss or corruption 35 Note You cannot mix and match capacities of disk drives in the Netra st D130 storage enclosure v To Add a Disk Drive 1 Remove the front panel by pressing the latches on both ends and pulling the panel away from the enclosure FIGURE 4 1 Removing the Front Panel 2 Select any available slot in the Netra st D130 storage enclosure fo
58. y peripherals installed in the host system The overall SCSI bus length cannot exceed 6 meters The SCSI bus length for the cables inside the Netra st D130 storage enclosure is 1 meter If you are connecting another type of peripheral in this daisy chain refer to the documentation that you received with that peripheral for its internal SCSI bus length 5 Get the 36 meter SCSI cable from the ship kit 6 Connect one end of the SCSI cable to the SCSI OUT port of the first Netra st D130 storage enclosure 7 Connect the other end of the SCSI cable to the SCSI IN port on the second Netra st D130 storage enclosure or peripheral Host system 1 0 Netra st D130 enclosures E NP SCSI IN port ES SCSI OUT port am E O O SCSI IN port o 29 ouo FIGURE 3 3 Daisy Chaining Netra st D130 Storage Enclosures 8 Determine if you need to install an external terminator at the end of the SCSI daisy chain m If the last device in the SCSI daisy chain is a Netra st D130 storage enclosure or some other type of UltraSCSI device do not install an external terminator on the device The on board autoterminator in the device functions in UltraSCSI mode m If the last device in the SCS
Download Pdf Manuals
Related Search
Related Contents
Samsung SM-N915FY Наръчник за потребителя User manual S Class series Au programme - Jura Sud Pays de l`enfant GDS-1102A-U User Manual 8600 - Dwyer Instruments, Inc. 力一メイトサ一ヒ`スセンタ一 SA RATT。 Software Release Memo - Service, Support 031_身体組成分析装置(49KB、PDF形式) Panasonic DMC-GH1K Copyright © All rights reserved.