Home
Ultra Enterprise 450 Server and Sun Ultra 450 Workstation
Contents
1. 10 lat washer 18 8 oa 8 8 flat washer 8 8 lock washer 8 G Installing the Rack Handle and Rear Bracket 1 Disconnect all cables from the Ultra Enterprise 450 server or Sun Ultra 450 workstation chassis 2 Carefully turn the chassis onto its left side Do not lift the chassis using the plastic parts at the front of the chassis or the side panels where they overhang at the rear Roll the system onto a solid surface that spaces the unit about 2 inches 5 cm off the floor for example use a pair of wooden boards Do not allow any of the weight to rest on the plastic parts at the front of the chassis How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 3 3 Install the rack handle and rear bracket onto the chassis bottom as shown below Use four M5 x 12 screws for each bracket Installing the Tray and Slide Assemblies 1 Remove the front door of the cabinet a For a Sun expansion cabinet lift the door off the hinge pins a For a Sun server cabinet pull off the front panel then lift the door 4 Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 2 Extend the slides fully How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 5 3 Attach one short slide mounting bracket to the front and one long slide mounting bracket to the rear of each slide Use two 8 screws flat washers lock washers and n
2. an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements RESTRICTED RIGHTS Use duplication or disclosure by the U S Government is subject to restrictions of FAR 52 227 14 g 2 6 87 and FAR 52 227 19 6 87 or DFAR 252 227 7015 b 6 95 and DFAR 227 7202 3 a DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 1997 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l au
3. Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide Qe Sun microsystems THE NETWORK IS THE COMPUTER Sun Microsystems Computer Company A Sun Microsystems Inc Business 901 San Antonio Road Palo Alto CA 94303 USA 415 960 1300 fax 415 969 9131 Part No 805 1912 10 Revision B October 1997 Copyright 1997 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 USA All rights reserved This product or document is protected by copyrightand distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo AnswerBook SunDocs Solaris Ultra and Ultra Enterprise are trademarks registered trademarks or service marks of Sun Microsystems Inc in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon
4. ckmount tray is extended Caution If your rack enclosure does not have stabilizer legs secure it sufficiently to support the total weight of the system when it is fully extended 8 Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 3 Lift the chassis and position it on the tray assembly Alternatively you can set the rear wheels on the tray assembly and then roll the unit into position 4 Secure the system chassis to the tray assembly using five M5 x 12 mm screws Use two screws for the rack handle at the front of the chassis and three screws for the rear bracket How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 9 5 Press the locking mechanism on each slide and slide the system all the way to the rear of the enclosure The levers for the left and right sides operate in opposite directions Check that the system is installed in the rack level and centered so that it does not rub against the rails Adjust if necessary and retighten the screws 6 Secure the rackmount handle to the rack rails using two 10 screws and flat washers as shown in the next figure These screws secure the system inside the rack To service the system remove these screws and washers from the rackmount handle and slide the system out of the rack on its rails After service is completed slide the system all the way to the rear of the enclos
5. r s Guide Preface Vv Ordering Sun Documents SunDocs is a distribution program for Sun Microsystems technical documentation Contact SunExpress for easy ordering and guick delivery You can find a listing of available Sun documentation on the World Wide Web TABLE P 1 SunExpress Contact Information Country Telephone Fax Belgium 02 720 09 09 02 725 88 50 Canada 1 800 873 7869 1 800 944 0661 France 0800 90 61 57 0800 90 61 58 Germany 01 30 81 61 91 01 30 81 61 92 Holland 06 022 34 45 06 022 34 46 Japan 0120 33 9096 0120 33 9097 Luxembourg 32 2 720 09 09 32 2 725 88 50 Sweden 020 79 57 26 020 79 57 27 Switzerland 0800 55 19 26 0800 55 19 27 United Kingdom United States 0800 89 88 88 1 800 873 7869 0800 89 88 87 1 800 944 0661 World Wide Web http www sun com sunexpress Sun Documentation on the Web The docs sun com web site enables you to access Sun technical documentation on the World Wide Web You can browse the docs sun com archive or search for a specific book title or subject at http docs sun com vi Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 Sun Welcomes Your Comments We are interested in improving our documentation and welcome your comments and suggestions You can email your comments to us at smcc docs sun com Please include the part number of your document in the subject line of your email Preface vii viii Ultra Ente
6. rant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun CETTE PUBLICATION EST FOURNIE EN L ETAT ET AUCUNE GARANTIE EXPRESSE OU IMPLICITE N EST ACCORDEE Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS CE DENI DE GARANTIE NE S APPLIOUERAIT PAS DANS LA MESURE OU IL SERAIT TENU JURIDIOUEMENT NUL ET NON AVENU Adobe PostScript Contents Preface v How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 1 Inventory 2 Installing the Rack Handle and Rear Bracket 3 Installing the Tray and Slide Assemblies 4 Installing the Chassis 8 Contents iii iv Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 Preface The Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide shows you how to install your system in a Sun system or expansion cabinet or other EIA compliant rack enclosure Related Documents The following documents contain topics that relate to the information in this guide m Ultra Enterprise Expansion Cabinet Installation and Service Manual m 56 Inch Data Center Expansion Cabinet Installation Manual m Ultra Enterprise 450 Server Owner s Guide m Sun Ultra 450 Workstation Owne
7. rprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 gt How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation Caution The chassis is heavy In the following procedures two people are reguired to move the chassis Two people are also reguired to align and install the rackmount tray and slide assemblies in the rack Caution Install the chassis as low as possible in the rack enclosure For best stability do not install the chassis above eguipment that weighs less than it does Caution For proper ventilation each Ultra Enterprise 450 server or Sun TM UltraTM 450 workstation in the rack enclosure reguires 92 sguare inches 593 sguare cm of unrestricted airflow into the front of the system and 97 sguare inches 626 sguare cm of unrestricted exhaust port at the rear of the system Maintain a minimum 1 5 inches 3 8 cm clearance between the system and any front or rear doors How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 1 2 Inventory The rack mounting kit contains the following parts Rear bracket Rackmount tray Top left bracket Top right bracket Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 The rack mounting kit also contains the following screws washers and nuts shown actual size mm r M5 x 12 screw 13 10 screw 18 8 screw 8
8. torisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun AnswerBook SunDocs Solaris Ultra et Ultra Enterprise sont des marques de fabrique ou des marques d pos es ou marques de service de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couv
9. ure and reinstall the screws and washers 10 Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 7 Install the right and left top brackets using 10 screws and flat washers Install the brackets so that they are as close as possible to the top edges of the system choose the closest holes in the rack that line up for this purpose For each bracket use two screws at the front of the cabinet Tdi as eee CFFI BODD OPAIIIIIIIIIIIIIIIIII PITTI ILAIA ddd fd 8 If your rack has stabilizing legs raise the leveling pads and retract the stabilizer legs 9 Connect the chassis to the power sequencer See instructions supplied with the rackmount enclosure How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 11 10 Route data cables as appropriate and connect them to the chassis 11 Install the rack front door or front panels However if the front door or front panels do not meet the airflow reguirements on page 1 do not install them 12 Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997
10. uts for each bracket Use screw holes appropriate for the depth of the cabinet 6 Ultra Enterprise 450 Server and Sun Ultra 450 Workstation Rackmounting Guide October 1997 4 Attach the front and rear slide mounting brackets for each slide to the rack mounting rails using 10 screws and flat washers Do not tighten the screws completely at this time Be sure to use the correct positions in the rack Locate each bracket with the bottom edge centered between the lowest 5 8 inch 1 6 cm spacing on the rail To mount the unit in an EIA standard rack allow 14 unit spaces To mount two units allow 28 unit spaces Use a level to ensure that the rackmount tray is level front to back and left to right Also make sure that the rackmount tray is centered precisely between the left and right walls of the rack enclosure This will ensure that the system chassis when installed slides freely within the rack enclosure without interference After leveling and centering the rackmount tray tighten the front and rear bracket screws completely How to Rackmount the Ultra Enterprise 450 Server or Sun Ultra 450 Workstation 7 Installing the Chassis 1 Turn the chassis right side up Do not lift the chassis using the side panels or the plastic parts at the front of the chassis 2 Extend the stabilizer legs and lower the leveling pads to ensure that the cabinet cannot move or tip forward when the ra