Integrated Lights Out Manager (ILOM) Administration Guide for ILOM
Contents
1. If the host is booting you will see its bootup messages 8 3 Viewing System Components Indicators and Sensors On the CLI components indicators LEDs and sensors are located in SYS Note When displayed on the WebGUI the components indicators and sensors are divided into separate screens They are described in Section 9 2 Viewing Replaceable Component Information on page 9 2 Section 9 3 Viewing Sensors on page 9 5 Section 9 4 Viewing Indicator LEDs and Controlling the Locate LED on page 9 8 The following display shows the contents of a typical SYS 8 2 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Note The displays in this section are examples For exact sensor information see your platform supplement gt show SYS SYS Targets INTSW LOS gd EAR_SVC O ue N lt Q EMP_FAULT WER OCATE ERVICE _ 12V _ 1V2 Q CnvevHHAH Dn Gy lt SaS w lt W n w K FT3 PROC IO PSO PS1 PS2 HD Properties additional information appears here Chapter 8 Managing the Host Using the CLI 8 3 8 4 To display information about a particular sensor indicator or component use the show command In this example SYS SASBP represents the disk backplane It has the following targets gt show SYS SASBP SYS SASBP Targets IDO D1 AMB DDO DD1 DD2 DD3 Got
2. 1 Log in to the WebGUI as administrator 2 Select User Management gt RADIUS The RADIUS Settings page appears 13 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 FIGURE 13 1 RADIUS Page REFRESH LOG OUT istrator root SP Hostname Sun Integrated Lights Out Manager Remote Control Maintenance A a e a System Information System Monitoring Configuration User Management aeea pressib S Oaia M User Accounts Active Sessions LDAP Settings l Radius Radius Settings Configure ILOM access for RADIUS users on this page Select a default role for all of your RADIUS users either Administrator or Operator Enter the IP address of your RADIUS server Enter the port used to communicatd with your RADIUS server the default port is 1812 Enter the encryption key your RADIUS server uses to authenticate users State Enabled Role Operator v IP Address Port 1812 Encryption Save 3 Complete the settings For details see TABLE 13 1 4 Click Save for your changes to take effect 13 2 2 Configuring RADIUS Using the CLI 1 Log in to the CLI as administrator 2 Navigate to SP clients radius 3 Set the parameters shown in TABLE 13 1 13 2 3 RADIUS Parameters TABLE 13 1 describes the RADIUS parameters for the WebGUI and the CLI TABLE 13 1 RADIUS WebGUI and CLI Settings WebGUI CLI Description Defau
3. 2 Deleting an SNMP community Click the Communities link or scroll down to the Communities list Select the radio button of the SNMP community to be deleted Click Delete under the SNMP Communities list A confirmation dialog box appears Click OK to delete the SNMP community Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 APPENDIX A Command Line Interface Reference This chapter contains the following sections m Section A 1 CLI Command Quick Reference on page A 1 m Section A 2 CLI Command Reference on page A 6 A 1 CLI Command Quick Reference This section contains the most common ILOM commands used to administer your Sun server from the command line interface CLI TABLE A 1 Command Syntax and Usage Content Typeface Description Your input Fixed width Text that you type Type it exactly as shown bold Onscreen output Fixed width Text that the computer displays regular Variable Italic Replace these with a name or value you Square brackets Vertical bars choose Text in square brackets is optional Text separated by a vertical bar represents the only available values Select one A 1 TABLE A 2 General Commands Description Show all valid targets Log out of the CLI Display the version of the ILOM firmware running on the ILOM Display clock information Display all of the CLI commands Display the active ILOM se
4. Administrator root SP Hostname Sun Integrated Lights Out Manager System Information System Monitoring Configuration User Management Remote Control Maintenance System Management Access Alert Management Network Serial Port Clock Settings Syslog Serial Port Settings The internal serial port is the connection between the host server and the Service Processor that allows a SP user to access the host serial console The SP internal serial port speed must match the speed of the serial console port on the host server often referred to as serial port 0 COMO or dewttySO The external serial port is the DB 9 serial port on the blade Typically the internal and external serial port connections should run atthe same speed to avoid flow contral issues when connecting to the host console fram the SP external serial port Internal Serial Port This setting must match the setting for Serial Port 0 COM1 or dewttySO on the host operating system Baud Rate 93600 w External Serial Port Baud Rate a600 Flow Control none 3 Select the baud rate for the internal serial port from the Internal Serial Port drop down menu This setting must match the setting for serial port 0 COM1 or dev ttyS0 on the host operating system The baud rate value must match the speed that was specified for the BIOS serial redirection feature default is 9600 baud and the speed used for the boot loader and operating system c
5. Ethernet event externally initiated reset XIR F failover Fast Ethernet fdisk partition Fibre Channel FC Glossary 7 A hardware and software standard that enables systems to transmit data at twice the speed of standard parallel ports A nonvolatile programmable read only memory PROM that can be written to as well as read from An industry standard type of local area network LAN that enables real time communication between systems connected directly through cables Ethernet uses a Carrier Sense Multiple Access Collision Detection CSMA CD algorithm as its access method wherein all nodes listen for and any node can begin transmitting data If multiple nodes attempt to transmit at the same time a collision the transmitting nodes wait for a random time before attempting to transmit again A change in the state of a managed object The event handling subsystem can provide a notification to which a software system must respond when it occurs but which the software did not solicit or control A signal that sends a soft reset to the processor in a domain XIR does not reboot the domain An XIR is generally used to escape from a hung system in order to reach the console prompt A user can then generate a core dump file which can be useful in diagnosing the cause of the hung system The automatic transfer of a computer service from one system or more often a subsystem to another to provide redundant c
6. Server Power Control Control the system power from this page To change the host power state choose an option from the Actions drop down list immediate Power Off cuts power to the system Graceful Shutdown and Power Off attempts to bring the OS down gracefully then cuts power to the system Power On gives the system full power Power Cycle brings the system to power off then automatically powers the system back on Host is currently on Select Action x Save 3 To change the power status of the server select an action from the drop down list m Reset Select to reboot the server immediately Immediate Power Off Select to power off the server a Graceful Shutdown and Power Off Select to gracefully shut down the system operating system before the system is powered off a Power On Select to power on the server m Power Cycle Select to power off the server wait and then power on the server again 4 Click OK in the confirmation dialog to implement your selection 9 2 Viewing Replaceable Component Information This section describes how to view detailed information about the Sun server replaceable components sometimes referred to as field replaceable units FRUs and customer replaceable units CRUs Depending on the component you select information about the manufacturer component name serial number and part number might be displayed Hot Swappable and Hot Pluggable Compo
7. into Internet Protocol IP addresses such as 030 120 000 168 A distributed name resolution system that enables computers to locate other computers on a network or the Internet by domain name The system associates standard Internet Protocol IP addresses such as 00 120 000 168 with host names such as www sun com Machines typically get this information from a DNS server A circuit board that holds double the amount of surface mount memory chips than a single inline memory module SIMM holds A DIMM has signal and power pins on both sides of the board whereas a SIMM has pins on only one side of the board A DIMM has a 168 pin connector and supports 64 bit data transfer A protocol that enables a DHCP server to assign Internet Protocol IP addresses dynamically to systems on a Transmission Control Protocol Internet Protocol TCP IP network A type of random access memory RAM that stores information in integrated circuits that contain capacitors Because capacitors lose their charge over time DRAM must be periodically recharged A type of nonvolatile programmable read only memory PROM that can be erased by exposing it to an electrical charge The sudden dissipation of static electrical charge ESD can easily destroy semiconductor components Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 enhanced parallel port EPP erasable programmable read only memory EPROM
8. FIGURE 2 1 Integrated Lights Out Manager Network Settings Page mi tor rc Hostname Sun Integrated Lights Out Manager System Management Access Alert Management Network Serial Port Clock Settings Syslog Network Settings View the MAC address and configure network settings for the Service Processor from this page DHCP is the default mode but you can manually configure the Netmask Gateway and IP address Select the radio button next to the appropriate mode then enter settings as needed MAC Address 00 14 4F 26 DC E5 Obtain an IP Address Automatically use DHCP Use the Following IP Address IP Address oez OCS Subnet Mask 255 2552520 Gateway osz oe 5 Click Save when you are done 2 12 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 3 Using the Command Line Interface This chapter describes how to use the ILOM s command line interface CLI The sections include m Section 3 1 Using CLI Commands on page 3 1 m Section 3 2 Command Syntax on page 3 4 To connect to the CLI see Section 2 1 Connecting to the ILOM on page 2 1 3 1 ele Using CLI Commands This section describes how to use CLI commands CLI commands are case sensitive CLI Namespace The CLI architecture is based on a hierarchical namespace which is a predefined tree that contains every managed object in the system
9. RCMP e Multiple Payloads e Enhanced Authentication e Encryption PEF and Alerting Commands Get PEF Capabilities Arm PEF Postpone Timer Set Get PEF Configuration Parameters Set Get Last Processed Event ID Alert Immediate PET Acknowledge 11 4 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 TABLE 11 1 Supported IPMI 2 0 Commands Continued Supported IPMI 2 0 Commands Continued Sensor Device Commands Get Sensor Reading Factors Set Get Sensor Hysteresis Set Get Sensor Threshold Set Get Sensor Event Enable Get Sensor Reading Set Sensor Type ERU Device Commands Get FRU Inventory Area Info Read Write FRU Data SDR Device Commands Get SDR Repository Info Get SDR Repository Allocation Reserve SDR Repository Get Add SDR Partial Add SDR Clear SDR Repository Get SDR Repository Time Enter Exit SDR Repository Update Run Initialization Agent SEL Device Commands Get SEL Info Get SEL Allocation Info Reserve SEL Get Add SEL Entry Clear SEL Set Get SEL Time Chapter 11 Using Intelligent Platform Management Interface IPMI 11 5 TABLE 11 1 Supported IPMI 2 0 Commands Continued Supported IPMI 2 0 Commands Continued LAN Device Commands Get LAN Configuration Parameters Suspend BMC ARPs Serial Modem Device Commands Set Get Serial Modem Configuration Set Serial Modem MUX Get TAP Response Codes Serial Modem Connect
10. Software that organizes data blocks on physical disk drives into logical volumes which makes the disk data independent of the physical path name of the disk drives Volume manager software provides data reliability through disk striping concatenation mirroring and dynamic growth of metadevices or volumes Refers to the World Wide Web Consortium W3C is an international organization that governs Internet standards web server Software that provides services to access the Internet or an intranet A web server hosts web sites provides support for HTTP HTTPS and other protocols and executes server side programs wide area network WAN A network consisting of many systems that provides file transfer services A WAN can cover a large physical area sometimes worldwide X X 509 certificate The most common certificate standard X 509 certificates are documents containing a public key and associated identity information digitally signed by a Certificate Authority CA X Window System A common UNIX window system that enables a workstation or terminal to control multiple sessions simultaneously Glossary 22 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 Index A alerts configuring 9 10 ILOM 8 6 baud rate setting 7 3 BIOS password resetting 6 7 7 9 break sending 8 1 10 12 C case 3 1 CLI alerts 8 6 command syntax A 1 commands access settings A 4 alert A 3 cd A 6
11. TABLE 11 1 lists the supported IPMI 2 0 commands Note When a hard drive is unconfigured in the host OS the command ipmitool sdr elist shows it as Drive Present Hot Spare This means it is inserted but safe to remove For details on individual commands see the Intelligent Platform Management Interface Design Specification v2 0 A copy is available at http www intel com design servers ipmi spec htm TABLE 11 1 Supported IPMI 2 0 Commands Supported IPMI 2 0 Commands General Commands Get Device ID Cold Reset Warm Reset Get Self Test Results Set Get ACPI Power State Reset Set Get Watchdog Timer Set Get BMC Global Enables Clear Get Message Flags Enable Message Channel Receive Get Send Message Read Event Message Buffer Get Channel Authentication Capabilities Get Session Challenge Activate Close Session Set Session Privilege Level Get Session Info Set Get Channel Access Chapter 11 Using Intelligent Platform Management Interface IPMI 11 3 TABLE 11 1 Supported IPMI 2 0 Commands Continued Supported IPMI 2 0 Commands Continued Get Channel Info Command Set Get User Access Command Set Get User Name Set User Password Command Master Write Read Set Get Chassis Capabilities Get Chassis Status Chassis Control Chassis Identify Set Power Restore Policy Get System Restart Cause Set Get System Boot Options Set Get Event Receiver IPMI System Interface Support KCS BT
12. in the drive automatic or when you access the example you double click on a device on the host the remote drive the remote client sends a client sends a status message In status message In this case since this case since there is no there is no medium the status is medium the status is no no medium medium 3 Remote console application DVD device present Whenever Diskette device present started with no medium then the hosts asks automatic or Whenever the host asks medium is inserted manual the remote client sends manual the remote client sends a status message as medium a status message as medium present and also indicates the present and also indicates the medium change medium change 4 Remote console application Same as 3 Same as 3 started with medium inserted 5 Remote console application Next command from the host Next command from the host started with medium present will get a status message will get a status message then medium is removed indicating medium not present indicating medium not present 6 Remote console application Same as 3 Same as 3 started with image redirection 7 Remote console application Driver knows DVD redirection Driver knows DVD redirection started with image but stopped so it sends a medium stopped so it sends a medium redirection is stopped which is absent status on the next host absent status on the next diskette the only way to stop ISO query query redirection 8 Network failure The
13. you can interact with the ILOM to do the following establish secure remote control of your server monitor the status of hardware components remotely monitor system logs receive reports from replaceable components and redirect the server console For more on IPMI see Chapter 11 Simple Network Management Protocol SNMP interface ILOM also provides an SNMP v3 0 interface with limited support for SNMP v1 and SNMP v2c for external data center management applications such as Sun N1 System Manager IBM Tivoli and Hewlett Packard OpenView For more on SNMP see Chapter 14 Which interface you use depends on your overall system management plan and the specific tasks that you wish to perform Common Tasks That You Can Perform With ILOM TABLE 1 1 shows common tasks and the management interfaces used to perform each task TABLE 1 1 Common Tasks Web Task IPMI Interface CLI SNMP Redirect the system graphical console to a remote Yes client browser Connect a remote diskette drive to the system as a Yes virtual diskette drive Connect a remote CD ROM drive to the system as a Yes virtual CD ROM drive Monitor system fans temperatures and voltages Yes Yes Yes Yes remotely 1 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 1 1 2 TABLE 1 1 Common Tasks Continued Web Task IPMI Interface CLI SNMP Monitor system BIOS messages remotely Yes Yes Yes Monitor system operating system
14. Ole 0 0 0 0 disable ipmipet O 7 0 0 0 0 disable ipmipet Ol s 0 0 0 0 disable ipmipet Olg 0 0 0 0 disable ipmipet O 10 0 0 0 0 disable ipmipet Oju 0 0 0 0 disable ipmipet O 12 0 0 0 0 disable ipmipet O 13 0 0 0 0 disable ipmipet O 14 0 0 0 0 disable ipmipet O 16 0 0 0 0 disable ipmipet The alert table includes five columns Radio buttons Use to select an alert m Alert ID The number of the alert rule A number from 1 to 15 m Destination IP The IP address of the machine where the alert will be sent m Alert Level Displays the severity level of the alert Possible levels include TABLE 9 2 Alert Levels Name in Sensor Alert Levels Readings View Description Informational N A This level traps system events that are not related to sensors such as The host has booted Warning NC The sensor is outside of its normal range but not critical Chapter 9 Managing the Host Using the WebGUI 9 11 TABLE 9 2 Alert Levels Continued Name in Sensor Alert Levels Readings View Description Critical CT The sensor has crossed a critical threshold Non Recoverable NR The sensor has reached a threshold beyond the tolerance level of the corresponding component s Disable N A Don t send alerts at this level m Alert Type ipmipet indicating that all alerts are sent as IPMI PET traps 9 5 2 Configuring an Alert Configuring an alert requires administrator privileges 1 Select a r
15. SP clock usentpserver enabled disabled A 12 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Default none operator critical none SP clock TABLE A 13 Targets Properties and Values for the set Command Continued Valid Targets Properties Values Default SP services http servicestate enabled disabled SP services http SP services https servicestate enabled disabled SP services https SP services snmp engineid lt hexadecimal gt IP address port lt decimal gt 161 sets enabled disabled disabled traps enabled disabled disabled v1 enabled disabled disabled v2c enabled disabled disabled v3 enabled disabled enabled SP services snmp permissions rolrw ro community communityname SP services snmp user authenticationprotocol MD5 MD5 username authenticationpassword lt string gt null string permissions rolrw ro privacyprotocol none DES DES privacypassword lt string gt null string SP clients ldap binddn lt username gt none bindpw lt string gt none defaultrole administrator operator operator ipaddress lt ipaddress gt none none port lt decimal gt 389 searchbase lt string gt none state enable disabled disabled SP clients radius defaultrole administrator operator lt ipad operator ipaddress dress gt none none port lt decimal gt 1812 secret lt string gt none none state enable disabled disabled SP clients serve
16. by the BIOS will be UTC Microsoft Windows software does not respect time zones and sets the system clock to local time Therefore after the OS adjusts the RTC the time set by the BIOS will be local time a When the user sets the RTC using the host BIOS Setup screen Continuously through NTP if NTP is enabled on the ILOM NTP jumping is enabled to recover quickly from an erroneous update from the BIOS or user NTP servers provide UTC time Therefore if NTP is enabled on the ILOM the ILOM clock will be in UTC Through the CLI WebGUI and IPMI 7 8 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 7 4 Resetting the ILOM 1 Log in to the ILOM as administrator or operator 2 Select Maintenance gt Reset SP The Reset Service Processor page appears FIGURE 7 4 Reset Service Processor Page REFRESH Loc out 3 Role User Administrator root SP Hostname SUNSP0003BA84D771 Sun Integrated Lights Out Manager System Information System Monitoring Configuration User Management Remote Control Maintenance Firmware Upgrade Reset SP Reset Service Processor Resetting the SP disconnects your current LOM session You must log in again to continue working in ILOM 3 Click Reset SP to reset the ILOM The ILOM reboots The WebGUI is unavailable while the ILOM reboots 7 9 Resetting the ILOM and BIOS Passwords This procedure causes the ILOM to re
17. character case 3 1 clock settings A 5 command verbs overview 3 3 create A 7 delete A 7 displaying 6 11 exit A 8 help A 9 host A 5 load A 10 miscellaneous A 2 network and serial port A 3 options 3 3 reset A 11 set 6 5 A 12 show A 14 SNMP A 4 start A 18 stop A 19 user A 2 version A 20 namespaces 3 1 privilege levels 3 2 clock 9 15 A 2 settings 6 5 A 5 configuring alerts 9 10 customer replacable units CRUs 9 2 E event log clearing 8 9 9 13 9 15 interpreting time stamps 9 15 viewing 8 9 9 13 F fan sensors 9 5 field replacable units FRUs 9 2 firewall configuring B 1 firmware downgrading 7 10 upgrading 7 10 viewing revisions 9 17 Index 1 FRUs 9 2 H hardware power and WebGUI 9 1 redirecting keyboard and mouse 10 11 storage devices 10 13 replaceable components 9 2 viewing revisions 9 17 host serial console 7 2 HTTPS enabling 7 13 l ILOM alerts and CLI 8 6 and LDAP 12 1 to 12 5 to 12 6 clock 7 6 configuring alerts 9 10 default settings 1 3 Ethernet connection 2 2 managing network settings 6 3 managing serial port settings 6 1 managing user accounts 5 2 5 4 namespaces 3 1 power and WebGUI 9 1 redirecting keyboard and mouse 10 11 resetting password 6 7 7 9 serial connection 2 3 serial port configuring 7 1 tasks and management interfaces 1 2 time out 7 16 upgrading firmware 7 10 ILOM ports B 1 internal serial port
18. m Update entries in the directory 12 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 m Delete entries from the directory m Rename entries in the directory For example to update an entry in the directory an LDAP client submits the distinguished name of the entry with updated attribute information to the LDAP server The LDAP server uses the distinguished name to find the entry and performs a modify operation to update the entry in the directory The updated information is immediately available to all the distributed applications using that LDAP server To perform any of these LDAP operations an LDAP client needs to establish a connection with an LDAP server LDAP specifies the use of TCP IP port number 389 although servers may run on other ports Your Sun server can be a client of an LDAP server To use LDAP authentication you need to create a user on your LDAP server that your Sun server can authenticate or bind to so that the client has permission to search the proper directory on the LDAP server 123 Configuring LDAP To use LDAP you must configure your LDAP server according to your LDAP server documentation and your ILOM using either the CLI or the WebGUI This procedure requires detailed knowledge of your LDAP server configuration Before you begin gather basic network information about your LDAP server including its IP address Note This task is similar to config
19. 13 1 13 1 RADIUS Overview 13 1 13 2 Configuring RADIUS Settings 13 2 13 2 1 Configuring RADIUS Using the WebGUI 13 2 13 2 2 Configuring RADIUS Using the CLI 13 3 13 2 3 RADIUS Parameters 13 3 13 3 RADIUS Commands 13 4 13 3 1 show SP clients radius 13 4 13 3 2 set SP clients radius 13 5 13 3 3 show SP clients 13 6 14 Using Simple Network Management Protocol SNMP 14 1 14 1 About SNMP 14 1 14 1 1 How SNMP Works 14 1 14 2 SNMP Management Information Base MIB Files 14 2 14 3 MIBs Integration 14 3 14 4 About SNMP Messages 14 3 14 5 About ILOM and SNMP 14 4 14 5 1 Integrating the MIBs 14 4 14 5 2 Adding Your Server to Your SNMP Environment 14 4 viii Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 14 5 3 Configuring Receipt of SNMP Traps 14 5 14 6 Managing SNMP Users With the CLI 14 5 14 6 1 Adding a User Account 14 5 14 6 2 Deleting a User Account 14 5 14 6 3 Configuring User Accounts 14 5 14 6 3 1 Syntax 14 6 14 6 3 2 Targets Properties and Values 14 6 14 6 3 3 Examples 14 6 14 7 Managing SNMP With the WebGUI 14 7 14 7 1 Configuring SNMP Settings 14 7 14 7 2 Adding or Editing SNMP Users 14 9 14 7 3 Deleting an SNMP user 14 11 14 7 4 Adding and Editing SNMP Communities 14 11 14 7 5 Deleting an SNMP community 14 12 A Command Line Interface Reference A 1 A 1 CLI Command Quick Reference A 1 A 2 CLI Command Reference A 6 A 2 1 Using the cd Command A 6 A 2 2 Using the create Command A 7
20. 16 bit I want to see redirection in 8 bit Launch Redirection 4 If necessary set the mouse mode If you are not changing the mouse mode skip to Step 5 a Absolute mouse mode Select this setting for best performance when you are using a Solaris or Microsoft Windows operating system a Relative mouse mode Select this setting for best performance when you are using a Linux operating system Linux currently does not support Absolute mode a Select Remote Control gt Mouse Mode Settings The Mouse Mode Settings page appears Caution Do not change the mouse mode unless it is necessary as it causes the ILOM to reset itself FIGURE 10 2 Mouse Mode Settings Page Premnesn Loo our User Management Remote Control ah Redirection I Remote Power Control Mouse Mode Settings Mouse Mode Settings Select a mode for your local mouse to use while managing the host remotely Select Absolute mouse mode if your hostis running Windows OS or Solaris or Relative mouse mode for Linux OS You must reset the Service Processor to implement a change Mouse Mode Absolute v b Check to see if the mouse mode is set correctly and if it is proceed to Step 5 10 6 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 c If the mouse mode is set incorrectly select either Absolute or Relative mouse mode from the drop down menu A confirmation dialog box appears
21. 6 Managing the ILOM Using the CLI This chapter describes how to use the ILOM s Command Line Interface CLI The sections include m Section 6 1 Configuring the Serial Port on page 6 1 m Section 6 2 Configuring ILOM Network Settings on page 6 3 m Section 6 3 Setting the ILOM Clock on page 6 5 m Section 6 4 Resetting the ILOM on page 6 7 m Section 6 5 Resetting the ILOM and BIOS Passwords on page 6 7 m Section 6 6 Updating the ILOM Firmware on page 6 7 m Section 6 7 Enabling HTTP or HTTPS Web Access on page 6 8 m Section 6 8 Viewing ssh Settings on page 6 10 m Section 6 9 Displaying ILOM Information on page 6 11 6 1 Configuring the Serial Port You can display or configure the ILOM serial port settings from the CLI The ILOM has two serial ports an internal host port that interfaces directly with the host server using the start SP console command and an external port that is exposed on the back of the server 6 1 1 Displaying Serial Port Settings Type the following command to display settings for the external serial port show SP serial external 6 1 Type the following command to display settings for the host serial port show SP serial host 6 1 2 Configuring Serial Port Settings Use the set command to change properties and values for serial port settings Port settings have two sets of properties pending and active The active settings are th
22. A 2 3 Using the delete Command A 7 A 2 4 Using the exit Command A 8 A 2 5 Using the help Command A 9 A 2 6 Using the load Command A 10 A 2 7 Using the reset Command A 11 A 2 8 Using the set Command A 12 A 2 9 Using the showCommand A 14 A 2 10 Using the start Command A 18 A 2 11 Using the stop Command A 19 Contents ix A 2 12 Using the version Command A 20 B ILOM Ports B 1 Glossary Glossary 1 Index Index 1 x Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Preface The Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 provides instructions for managing Sun servers using the Integrated Lights Out Manager ILOM is included on certain Sun servers If you have one of these servers it will include an ILOM supplement which contains platform specific information such as sensors and thresholds and details about the hardware Sun Blade 6000 products consist of a chassis containing multiple replacable server modules On these products the chassis is equipped with a separate service processor that supports chassis level functionality such as fans and power supplies and that provides access to the service processors on the server modules This chassis level service processor is called a Chassis Management Module CMM a This document covers the service processor s in the server modules m Separate documents provide information about the CMM See the documenta
23. Alerts on page 9 10 for WebGUI instructions 14 6 14 6 1 14 6 2 14 6 3 Managing SNMP Users With the CLI You can add delete or configure SNMP user accounts from the CLI By default SNMP v3 is enabled and SNMP v1 and v2c are disabled To do this on the WebGUL see Section 14 7 Managing SNMP With the WebGUI on page 14 7 Adding a User Account To add an SNMP v3 read only user account type the following command create SP services snmp users username authenticationpassword password To add an SNMP v1 v2c user account type the following command create SP services snmp communities communityname Deleting a User Account To delete an SNMP v3 user account type the following command delete SP services snmp users uwusername To delete an SNMP v1 v2c user account type the following command delete SP services snmp communities communityname Configuring User Accounts To configure SNMP user accounts use the set command Chapter 14 Using Simple Network Management Protocol SNMP 14 5 14 6 3 1 14 6 3 2 Syntax set target propertyname value Targets Properties and Values These targets properties and values are valid for SNMP user accounts TABLE 14 1 SNMP User Account Targets Properties and Values Target Property Value Default SP services snmp communities permissions rolrw ro communityname SP services snmp users username authenticationprotocol MD5 ISHA MD5 authenticat
24. Command Start the host system Stop the host system Reset the host system Start a session to connect to the host console Stop the session connected to the host console TABLE A 9 Clock Settings start SYS stop SYS reset SYS start SP console stop SP console Description Command Set the ILOM clock to set SP clients ntp server 1 address ntp Paddress synchronize with a primary NTP server Set the ILOM clock to set SP clients ntp server 2 addressntp Paddress2 synchronize with a secondary NTP server Appendix A Command Line Interface Reference A 5 A 2 CLI Command Reference This section provides reference information about the CLI commands A 2 1 Using the cd Command Use the cd command to navigate the namespace When you cd to a target location that location then becomes the default target for all other commands Using the default option with no target returns you to the top of the namespace Typing just cd displays your current location in the namespace Typing help targets displays a list of all targets in the entire namespace Syntax ed target Options d default h help Targets and Properties Any location in the namespace Examples To create a user named sally cd to SP users then execute the create command with SP users as the default target gt cd SP users gt create sally To find your location type cd gt cd SP users A 6 Integrated Lig
25. Event Trap PET port port number power cycling power on self test POST PowerPC Preboot Execution Environment PXE Glossary 15 A set of privileges granted or denied to a user or group that specify read write or execution access to a file or directory For access control permissions state whether access to the directory information is granted or denied and the level of access that is granted or denied An actual hardware address that matches a memory location Programs that refer to virtual addresses are subsequently mapped to physical addresses A mechanism that configures the service processor to take selected actions when it receives event messages for example powering off or resetting the system or triggering an alert A configured alert triggered by a hardware or firmware BIOS event A PET is an Intelligent Platform Management Interface IPMI specific Simple Network Management Protocol SNMP trap which operates independently of the operating system The location socket to which Transmission Control Protocol Internet Protocol TCP IP connections are made Web servers traditionally use port 80 the File Transfer Protocol FTP uses port 21 and Telnet uses port 23 A port enables a client program to specify a particular server program in a computer on a network When a server program is started initially it binds to its designated port number Any client that wants to use that server must send a reques
26. Technology that provides the capability for out of band communication with the server even if the operating system is not running This enables the system administrator to switch the server on and off view system temperatures fan speeds and so forth and restart the system from a remote location A directory service protocol used for the storage retrieval and distribution of information including user profiles distribution lists and configuration data LDAP runs over Transmission Control Protocol Internet Protocol TCP IP and across multiple platforms A software server that maintains an LDAP directory and service queries to the directory The Sun Directory Services and the Netscape Directory Services are implementations of an LDAP server A boot loader for Linux A group of systems in close proximity that can communicate via connecting hardware and software Ethernet is the most widely used LAN technology The processor or system on which a software application is running A system event that impairs service but not seriously A tree like hierarchical system for classifying information about resources in a network The MIB defines the variables that the master Simple Network Management Protocol SNMP agent can access The MIB provides access to the server s network configuration status and statistics Using SNMP you can view this information from a network management station NMS By industry agreement individual develop
27. Using the WebGUI 7 7 a An IPMI command for example me reset cold A command line interface CLI command for example reset SP WebGUI operation for example from the Maintenance tab select Reset SP a An ILOM firmware upgrade Note Log event timestamps might appear different between host and client systems because of time zone adjustment The timestamps on events reported in the server s system event log and IPMI logs are always based on GMT UTC However when you view system information from a client system using the GUI or IPMItool the timestamps displayed are adjusted based on the time zone of the client system Therefore the same event can appear to have two different timestamps when viewed directly from the host and from a client system in a different time zone After an ILOM reboot the ILOM clock is changed by the following m When the host is booted The host s BIOS unconditionally sets the ILOM time to that indicated by the host s RTC The host s RTC is set by the following operations a When the host s CMOS is cleared as a result of changing the host s RTC battery or inserting the CMOS clear jumper on the motherboard The host s RTC starts at Jan 1 00 01 00 2002 a When the host s operating system sets the host s RTC The BIOS does not consider time zones Solaris and Linux software respect time zones and will set the system clock to UTC Therefore after the OS adjusts the RTC the time set
28. a whole One feature of the ACPI enables the OS to modify the voltage and frequency of a Glossary 1 CPU in response to system load thus enabling the system s main power consuming element the CPU to vary its power consumption based on system load Advanced Programmable Interrupt Controller APIC A device that manages interrupt requests for multiple central processing units CPUs The APIC decides which request has the highest priority and sends an interrupt to the processor for that request Advanced Technology Attachment ATA A specification that describes the physical transport electrical and command protocols used to attach storage devices to host systems Advanced Technology Attachment Packet Interface ATAPI An extension to the Advanced Technology Attachment ATA standard for connecting removable media storage devices in host systems including CD DVD drives tape drives and high capacity diskette drives Also called ATA 2 or ATA ATAPI agent A software process usually corresponding to a particular local managed host that carries out manager requests and makes local system and application information available to remote users alert A message or log generated by the collection and analysis of error events An alert indicates that there is a need to perform some hardware or software corrective action Alert Standard Format ASF A preboot or out of band platform management specification that enable
29. as administrator Only accounts with administrator privileges are enabled to modify SNMP settings 2 Select Configuration gt System Management Access gt SNMP The SNMP Settings page appears Chapter 14 Using Simple Network Management Protocol SNMP 14 7 FIGURE 14 2 SNMP Settings User root Administrator Server SUNSPO20000970192 Sun Integrated Lights Out Manager System Information System Monitoring Configuration User Management Remote Control Maintenance System Management Access Alert Management Network Serial Port Clock Settings Web Server SNMP SSL Certificate SNMP Settings View and modify SNMP settings x Communities x Users Port 161 Permit I Set Requests I v1 Protocol I v2e Protocol M y3 Protocol 3 Type the port number in the Port field 4 Enable or disable Set Requests by selecting or clearing the Set Requests check box If Set Requests is disabled all SNMP objects are read only 5 Select a check box to enable SNMP v1 v2c or v3 SNMP v3 is enabled by default You can independently enable or disable v1 v2c and v3 protocol versions 6 Click Save for your settings to take effect 7 At the bottom of the page you can also add edit or delete SNMP communities as well as SNMP users See FIGURE 14 3 14 8 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 FIGURE 14 3 SNMP Communities and Users SNMP Communities Ad
30. boot loader that can install two or more operating systems OS onto a single system and that can manage which OS to boot at power on An interface that uses graphics along with a keyboard and mouse to provide easy to use access to an application A structure attached to or part of a semiconductor device that can dissipate heat to the surrounding environment A system such as a backend server with an assigned Internet Protocol IP address and host name The host is accessed by other remote systems on the network Part of the 32 bit Internet Protocol IP address used to identify a host on a network The name of a particular machine within a domain Host names always map to a specific Internet Protocol IP address Describes a component that is safe to remove or add while the system is running Typically the system must be rebooted before the hot plug component is configured into the system Describes a component that can be installed or removed by simply pulling the component out and putting a new component into a running system The system either automatically recognizes the component change and configures it or requires user interaction to configure the system However in neither case is a reboot required All hot swappable components are hot pluggable but not all hot pluggable components are hot swappable The Internet protocol that retrieves hypertext objects from remote hosts HTTP messages consist of requests from clien
31. data that is stored locally often with instructions or the most frequently accessed information Cached data does not have to be retrieved from a remote server again when requested A cache increases effective memory transfer rates and processor speed Public key data assigned by a trusted Certificate Authority CA to provide verification of an entity s identity This is a digitally signed document Both clients and servers can have certificates Also called a public key certificate Certificate Authority CA client command line interface CLI Common Information Model CIM console Coordinated Universal Time UTC core file critical event custom JumpStart customer replaceable unit CRU D Data Encryption Standard DES Glossary 4 A trusted organization that issues public key certificates and provides identification to the owner of the certificate A public key Certificate Authority issues certificates that state a relationship between an entity named in the certificate and a public key that belongs to that entity which is also present in the certificate In the client server model a system or software on a network that remotely accesses resources of a server on a network A text based interface that enables users to type executable instructions at a command prompt An open systems information model published by the Distributed Management Task Force DMTF that enables a common applicati
32. examples The sensor names ranges and functions might be different on your system For details see your platform supplement Note If the server is powered off many components will appear as no reading To power it on see Section 9 1 Controlling Power to the Host Server on page 9 1 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 FIGURE 9 4 Sample Sensor Readings Page Ro dministra 0 SPH ame SUNSPO Sun Integrated Lights Out Manager Sensor Readings Indicators Event Logs Sensor Readings View readings for system sensors Click on a sensor name for more information including threshold values Sensor Readings Name Type Reading JSYS MB T_AMB Temperature 29 000 degrees C 3 ISYS MBIV_BAT Voltage 3 152 Volts 7 ISYS MBM_ 3V3STBY Voltage 3 166 Volts ISYSIMBINV_ 3V3 Voltage 3 322 Volts ISYS MBAV_ 5V Voltage 4 966 Volts ISYSIMBIV_ 12V Voltage 12 096 Volts ISYSIMBAV_ 12V Voltage 12 350 Volts ISYSIMBIV_ 2V5 Voltage 2 556 Volts ISYSIMBAV_ 1V8 Voltage 1 830 Volts ISYSIMBIV_ 1V 2 Voltage 1 220 Volts JSYS FIOBD T_AMB Temperature 23 000 degrees C JSYS PDB T_AMB Temperature 23 000 degrees C E ISYSISASBP T_AMB Temperature 21 000 degrees C JSYSIFIOBD PRSNT Entity Presence Present JSYS FIOBD USBFAIL Entity Fault Predictive Failure Deasserted ISYSIFIOBD LEDBD PRSNT Entity Presence Present ISYSIPSO PRSNT Entity Presence Present I
33. file systems and network parameters throughout a network of computer systems An internal circuit board or card that connects a workstation or server to a networked device A powerful workstation with one or more network management applications installed The NMS is used to remotely manage a network A number used by software to separate the local subnet address from the rest of a given Internet Protocol IP address An Internet standard for Transmission Control Protocol Internet Protocol TCP IP networks NTP synchronizes the clock times of networked devices with NTP servers to the millisecond using Coordinated Universal Time UTC An addressable point or device on a network A node can connect a computing system a terminal or various peripheral devices to the network A system interrupt that is not invalidated by another interrupt nonvolatile memory nonvolatile random access memory NVRAM O object identifier OID OpenBoot PROM OpenIPMI Operator out of band OOB system management P parity partition Peripheral Component Interconnect PCI Peripheral Interface Controller PIC Glossary 14 A type of memory that ensures that data is not lost when system power is off A type of random access memory RAM that retains information when system power is off A number that identifies an object s position in a global object registration tree Each node of the tree is assigned a nu
34. log in 4 4 log out 4 4 overview 1 1 remote console 10 1 setting clock 7 6 time out 7 16 Index 3 Index 4 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007
35. messages remotely Yes Yes Yes Interrogate system components for their IDs and their Yes Yes Yes serial numbers Redirect the system serial console to a remote client No Yes Yes Monitor system status health check remotely Yes Yes Yes Yes Interrogate system network interface cards remotely Yes Yes Yes for MAC addresses Manage user accounts remotely Yes Yes Yes Manage system power status remotely power on Yes Yes Yes power off power reset Monitor and manage environmental settings for key Yes Yes Yes Monitor system components CPUs motherboards fans only ILOM Default Settings Sun has configured the ILOM card and ILOM firmware on your server to reflect the most common default settings used in the field It is unlikely that you will need to change any of these defaults which appear in TABLE 1 2 TABLE 1 2 ILOM Default Settings System Component Default Status Action Required Service Processor card Preinstalled None Service Processor firmware Preinstalled None IPMI interface Enabled None WebGUI Enabled None Command line interface CLI Enabled None SNMP interface Enabled None Chapter 1 ILOM and System Management Overview 1 3 1 1 3 ILOM and Sun Blade 6000 Systems A Sun Blade 6000 system consists of a chassis with a number of servers called server modules inside Each server consists of a PC card that draws its power and cooling from the chassis On these systems each server module is equipped with its o
36. of the hierarchy are entries for individual people or resources Each entry is uniquely identified by a distinguished name dn A distinguished name consists of a name that uniquely identifies the entry at that hierarchical level and a path that traces the entry back to the root of the tree For example the distinguished name for jsmith is 12 1 dn uid jsmith ou people dc sun com Here uid represents the user ID of the entry ou represents the organizational unit in which the entry belongs and dc represents the larger organization in which the entry belongs FIGURE 12 1 shows how distinguished names are used to identify entries uniquely in the directory hierarchy FIGURE 12 1 LDAP Distinguished Names ou engineering dc sun dc com ou printers ou engineering dc sun dc com uid labprinter ou printers ou engineering dc sun dc com 12 2 LDAP Clients and Servers In the LDAP client server model LDAP servers make information about people organizations and resources accessible to LDAP clients Clients make changes to the LDAP database using a client utility usually bundled with the LDAP server When a change is made to the LDAP database all client applications see the change immediately so there is no need to update each distributed application An LDAP client can perform the following operations among others m Search for and retrieve entries from the directory m Add new entries to the directory
37. software has a keepalive The software has a keepalive mechanism The software will mechanism The software will detect keep alive failure since detect unresponsive client and there is no communication and close the socket as well as will close the socket assuming indicate to the driver that the the client is unresponsive Driver remote connection went away will send a no medium status to Driver will send a no medium the host status to the host 9 Client crashes Same as 8 Same as 8 10 4 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 10 1 3 Remote Console Security Only users with administrator privilege can use the remote console application m When users with operator privilege select Remote Console gt Redirection a login window prompts them for a user name and password They must enter the user name and password for an account with administrator privilege to proceed m Normally when users with administrator privilege click Remote Console gt Redirection the Launch Redirection page appears However this can be configured If SP services sso is set to disabled even users with administrator privilege are prompted to login again They can log in using the same user name and password or a different user name and password as long as it accesses a valid user account with administrator privilege To change the SP services sso 1 Log in to the CLI using an account with administrator pri
38. tftp archive newmainimage Are you sure you want to load the specified file y n y File upload is complete Firmware image verification is complete Do you want to preserve the configuration y n n Updating firmware in flash RAM Firmware update is complete ILOM will not be restarted with the new firmware 6 7 Enabling HTTP or HTTPS Web Access The ILOM allows you to enable HTTP or HTTPS and it allows you to automatically redirect HTTP access to HTTPS It also allows you to set the HTTP and HTTPS ports The properties are located in SP services http and SP services https 6 8 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 6 7 0 1 Use the set command to change properties and values as follows TABLE6 4 Values for HTTP and HTTPS Settings Desired State Target Values Enable HTTP only HTTP securedirect enabled HTTP servicestate disabled HTTPS servicestate disabled Enable HTTP and HTTPS HTTP securedirect disabled HTTP servicestate enabled HTTPS servicestate enabled Enable HTTPS only HTTP securedirect disabled HTTP servicestate disabled HTTPS servicestate enabled Automatically redirect HTTP securedirect enabled HTTP to HTTPS HTTP servicestate disabled HTTPS servicestate enabled Targets Properties and Values The following table shows the properties and values for HTTP and HTTPS TABLE 6 5 Valid Targets Properties and Values for HTTP and HTTPS Ta
39. that can be transmitted over a communication link Often used to describe the number of bits per second a network can deliver A device used to manage chassis environmental configuration and service functions and receive event data from other parts of the system It receives data through sensor interfaces and interprets this data by using the sensor data record SDR to which it provides an interface The BMC provides another interface to the system event log SEL Typical functions of the BMC are to measure processor temperature power supply values and cooling fan status The BMC can take autonomous action to preserve system integrity The rate at which information is transmitted between devices for example between a terminal and a server In the Lightweight Directory Access Protocol LDAP this refers to the authentication process that LDAP requires when users access the LDAP directory Authentication occurs when the LDAP client binds to the LDAP server System software that controls the loading of the operating system and testing of hardware at system power on BIOS is stored in read only memory ROM The unit of measurement for data transmission speed A program contained in read only memory ROM that automatically runs at system power on to control the first stage of system initialization and hardware tests The boot loader then transfers control to a more complex program that loads the operating system A copy of original
40. the Advanced tab The Advanced page appears Highlight IPMI 2 0 Configuration in the list then select Enter The IPMI 2 0 Configuration page appears Highlight LAN Configuration then select Enter The LAN Configuration page appears Fill in the IPMI 2 0 Configuration page Under IP Assignment select DHCP or Static If you selected Static fill in the IP address subnet mask and default gateway at the bottom of the page If you select DHCP your installation must meet the conditions described in Section 2 2 2 Using DHCP to Assign an IP Address on page 2 8 Select Commit to save your changes If you selected DHCP the BIOS utility automatically updates the address fields Caution You must use Commit to save the changes on this page Using F10 will not save your changes 2 2 4 Configuring the ILOM Using the CLI To configure the ILOM IP address using the CLI do the following 1 Connect to the ILOM CLI using one of the methods described in Section 2 1 Connecting to the ILOM on page 2 1 Log in to the ILOM Type the following command to set the working directory cd SP network Configure the IP address To configure a static IP address type set pendingipaddress Xxx xxx xx xx set pendingipnetmask yyy yyy yyy y set pendingipgateway 22Z 222Z 2Z ZZZ set pendingipdiscovery static 2 10 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 2 2 5 set commit
41. the filename of the Firmware Image that you want to load Clicking on the Browse button will allow you to select the firmware image file Once you do that click on the Upload button to upload the image file to the Service Processor Select image file to upload C Documents and Settings Michael I Browse Uploading image Please wait 10 Select Preserve Configuration to keep your ILOM settings Otherwise they will be overwritten m Upgradable Modules Select Service Processor Firmware to upgrade the firmware image and BIOS m Preserve Configuration Select this to retain your original configuration settings Deselect it to overwrite them 7 12 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 11 Click Start Upgrade or click Cancel to stop the upgrade Note If you choose to cancel the firmware upgrade operation the ILOM will reboot without the updated software You must close the web browser and log back in to the WebGUI before you can perform any other type of operation If you clicked Start Update a progress screen indicates that the firmware image is being upgraded Once the upgrade progress reaches 100 the firmware upgrade is complete After the upgrade operation has completed successfully the ILOM will automatically reboot This is done so that the image upgrade can take effect A screen prompt might ask you to repeat the upgrade This i
42. the sensors and posts an event in the event log SEL when they cross a threshold Some of these readings are also used to perform actions such as adjusting fan speeds illuminating LEDs and powering off the chassis The alert management view allows you to configure the system to send alerts to IP addresses Caution The ILOM tags all events or actions with LocalTime GMT or UDT Browser clients show these events in LocalTime This can cause apparent discrepancies in the event log When an event occurs on the ILOM the event log shows it in UDT but a client would show it in local time An alert is an IPMI Platform Event Trap PET generated when a sensor crosses the specified threshold For example if you configure an alert for critical thresholds the ILOM sends an IPMI trap to the specified destination when any sensor crosses the upper or lower critical CT threshold All alerts are IPMI PET traps as defined in the Intelligent Platform Management Interface IPMI v2 0 A special criteria informational is reserved for system events that are not related to sensors 8 6 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 8 5 1 8 5 2 8 5 2 1 8 5 2 2 The mapping between alert levels and sensors is TABLE 8 1 Mapping Between Alerts and Sensors Alert Sensor Warning Upper non critical lower non critical Critical Upper critical lower critical Non recoverable Upper non recov
43. time set by the BIOS will be UTC Microsoft Windows software does not respect time zones and sets the system clock to local time Therefore after the OS adjusts the RTC the time set by the BIOS will be local time a When the user sets the RTC using the host BIOS Setup screen a Continuously by NTP if NTP is enabled on the ILOM NTP jumping is enabled to recover quickly from an erroneous update from the BIOS or user NTP servers provide UTC time Therefore if NTP is enabled on the ILOM the ILOM clock will be in UTC a Through the CLI WebGUI and IPMI To set the ILOM clock see Section 6 3 Setting the ILOM Clock on page 6 5 9 16 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 9 7 Viewing ILOM Hardware Firmware and IPMI Versions This section describes how to view the ILOM hardware and firmware revisions as well as the Intelligent Platform Management Interface IPMI version 1 Log in to the ILOM as administrator or operator 2 Select System Information gt Versions The Version Information page appears see FIGURE 9 10 This page displays the ILOM hardware and software revisions FIGURE 9 10 Version Information Page REFRESH Loc our 4 Administrator ro SP Hostname SUNSP0003BA84D771 Sun Integrated Lights Out Manager System Information System Monitoring User Management Maintenance Versions Session Time Out Components Versions V
44. 1 4 1 1 Browser and Software Requirements 4 2 4 1 2 Users and Privileges 4 2 4 1 3 WebGUI Tasks 4 2 4 1 4 WebGUI Features 4 3 4 2 Logging Into the WebGUI 44 5 Managing User Accounts 5 1 5 1 User Accounts Overview 5 1 5 2 Managing User Accounts Using the CLI 5 2 5 2 1 Adding a User Account 5 2 5 2 2 Deleting a User Account 5 2 5 2 3 Displaying User Accounts 5 2 5 2 4 Configuring User Accounts 5 3 5 2 4 1 Syntax 5 3 5 2 4 2 Targets Properties and Values 5 3 5 3 Managing User Accounts Using the WebGUI 5 4 iv Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 5 3 1 Adding User Roles and Setting Privileges 5 4 5 3 2 Modifying User Accounts 5 7 5 3 3 Deleting User Accounts 5 9 Managing the ILOM Using the CLI 6 1 6 1 Configuring the Serial Port 6 1 6 1 1 Displaying Serial Port Settings 6 1 6 1 2 Configuring Serial Port Settings 6 2 6 1 2 1 Syntax 6 2 6 1 2 2 Targets Properties and Values 6 2 6 2 Configuring ILOM Network Settings 6 3 6 2 1 Displaying Network Settings 6 3 6 2 2 Configuring Network Settings 6 3 6 2 2 1 Syntax 6 3 6 2 2 2 Targets Properties and Values 6 4 6 3 Setting the ILOM Clock 6 5 6 3 1 Displaying Clock Settings 6 5 6 3 2 Configuring the Clock to Use NTP Servers 6 5 6 3 2 1 Syntax 6 5 6 3 2 2 Targets Properties and Values 6 5 6 3 3 Interpreting ILOM Clock Settings 6 6 6 4 Resetting the LOM 6 7 6 5 Resetting the ILOM and BIOS Passwords 6 7 6 6 Updating the ILOM Firmware 6 7 6
45. 3 hours See Section 7 9 Setting the ILOM Session Timeout Period on page 7 16 for details 1 Log in to the ILOM as administrator 2 Ensure that you can access the new flash image on the client machine that you are using to update the ILOM 3 If the server OS is running perform a clean shutdown 4 Select Maintenance gt Firmware Upgrade The Upgrade the Firmware page appears Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Caution Do not close the WebGUI using the Log Out button in the web browser when the ILOM is in Upgrade mode If you must close the WebGUI use the WebGUI s Cancel button FIGURE 7 5 Firmware Upgrade Page REFRESH LOG OUT J R Administrator root SP Integrated Lights Out Manager System Information System Monitoring Configuration User Management Remote Control Maintenance Firmware Upgrade Reset SP Firmware Upgrade A firmware upgrade will cause the server and ILOM to be reset Itis recommended that a clean shutdown ofthe server be done prior to the upgrade procedure An upgrade takes about 6 minutes to complete ILOM will enter a special made to load new firmware No other tasks can be performed in ILOM until the firmware upgrade is complete and ILOM is reset Enter Upgrade Mode 5 Click Enter Upgrade Mode A dialog box appears It asks you to confirm that you want to enter Upgrade mode 6 Click OK to enter Upgrade m
46. 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propri t intellectuels relatants la technologie qui est d crit dans ce document En particulier et sans la limitation ces droits de propri t intellectuels peuvent inclure un ou plus des brevets am ricains num r s a http www sun com patents et un ou les brevets plus suppl mentaires ou les applications de brevet en attente dans les Etats Unis et dans les autres pays Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y ena Le logiciel d tenu par des tiers et quicomprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Java AnswerBook2 docs sun com Sun Blade et Solaris sont des marques de fabrique ou des marques d pos es de Sun Microsyst
47. 7 2 IPMI 4 2 8 7 alerts and traps 8 6 IPMItool 11 2 overview 1 2 11 1 sensors 11 2 J Java Client remote console 1 2 L locate LED 9 9 log in WebGUI 4 4 log out WebGUI 4 4 M MAC address 1 4 2 4 2 5 2 8 Management Information Base MIB description of 14 2 N N1 1 4 NTP configuring 6 5 P PET alerts 8 7 ports B 1 R remote client redirecting hardware to 10 3 remote console overview 1 2 10 1 redirecting keyboard and mouse 10 11 storage devices 10 13 sending a break to host 10 12 starting 10 5 replaceable components 9 2 S sending a break to host 8 1 10 12 sensor thresholds 9 7 sensors fan sensors temperature 9 5 voltage 9 5 server module ILOM connecting through chassis serial connector 2 5 SNMP 14 1 to 14 7 and MIB 14 2 management software 14 3 overview 1 2 14 1 Port Standard 161 14 3 user accounts adding 14 5 configuring 14 5 deleting 14 5 Index 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 properties 14 6 v1 v2c v3 14 6 SP overview 1 1 software see ILOM specifications system B 1 system management using N1 1 4 system specifications B 1 T temperature sensors 9 5 thresholds sensors 9 7 time stamp 9 15 U user privilege levels 3 2 V viewing event log 8 9 9 13 replaceable components 9 2 voltage sensors 9 5 WwW WebGUI configuring serial port 7 1 controlling power 9 1
48. 7 Enabling HTTP or HTTPS Web Access 6 8 6 7 0 1 Targets Properties and Values 6 9 6 8 Viewing ssh Settings 6 10 6 9 Displaying ILOM Information 6 11 6 9 1 Displaying Version Information 6 12 Contents v 6 9 2 Displaying Available Targets 6 12 7 Managing the ILOM Using the WebGUI 7 1 7 1 Configuring the Serial Port 7 1 7 2 Configuring ILOM Network Settings 7 3 7 3 Setting the ILOM Clock 7 6 7 3 1 Setting the ILOM Clock Manually 7 6 7 3 2 Synchronizing the ILOM Clock with an NTP Server 7 7 7 3 3 Interpreting ILOM Clock Settings 7 7 74 Resetting the ILOM 7 9 7 5 Resetting the ILOM and BIOS Passwords 7 9 7 6 Upgrading the ILOM Firmware 7 10 7 7 Enabling HTTP or HTTPS Web Access 7 13 7 8 Uploading a New SSL Certificate 7 15 7 9 Setting the ILOM Session Timeout Period 7 16 7 10 Viewing Active Connections to the ILOM 7 17 8 Managing the Host Using the CLI 8 1 8 1 Controlling Power to the Host Server 8 1 8 2 Starting and Stopping the Host Console 8 2 8 3 Viewing System Components Indicators and Sensors 8 2 8 4 Setting the Locate LED 8 6 8 5 Managing ILOM Alerts 8 6 8 5 1 Displaying Alerts 8 7 8 5 2 Configuring Alerts 8 7 8 5 2 1 Syntax 8 7 8 5 2 2 Targets Properties and Values 8 7 8 5 3 Sending Test Alerts 8 8 8 6 Viewing and Clearing Event Logs 8 9 vi Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 10 11 8 7 Sending Logs to Other Machines 8 10 Managing the Host Using the W
49. A complete system unplug replug power cycle a An IPMI command for example me reset cold A command line interface CLI command for example reset SP m A WebGUI operation for example selecting Reset SP from the Maintenance tab a An ILOM firmware upgrade Note Log event timestamps might appear different between host and client systems because of time zone adjustment The timestamps on events reported in the server s system event log and IPMI logs are always based on GMT UTC However when you view system information from a client system using the GUI or IPMItool the timestamps displayed are adjusted based on the time zone of the client system Therefore the same event can appear to have two different timestamps when viewed directly from the host and from a client system in a different time zone After an ILOM reboot the ILOM clock is changed by the following a When the host is booted The host s BIOS unconditionally sets the ILOM time to that indicated by the host s RTC The host s RTC is set by the following operations a When the host s CMOS is cleared as a result of changing the host s RTC battery or inserting the CMOS clear jumper on the motherboard The host s RTC starts at Jan 1 00 01 00 2002 a When the host s operating system sets the host s RTC The BIOS does not consider time zones Solaris and Linux software respect time zones and will set the system clock to UTC Therefore after the OS adjusts the RTC the
50. A consortium of over 200 companies that authors and promotes standards for the purpose of furthering the ability to remotely manage computer systems Specifications from the DTMF include the Desktop Management Interface DMI the Common Information Model CIM and the Alert Standard Format ASF A grouping of hosts that is identified by a name The hosts usually belong to the same Internet Protocol IP network address The domain also refers to the last part of a fully qualified domain name FQDN that identifies the company or organization that owns the domain For example sun com identifies Sun Microsystems as the owner of the domain in the FQDN docs sun com domain name Domain Name Server DNS Domain Name System DNS dual inline memory module DIMM Dynamic Host Configuration Protocol DHCP dynamic random access memory DRAM E electrically erasable programmable read only memory EEPROM electrostatic discharge ESD Glossary 6 The unique name assigned to a system or group of systems on the Internet The host names of all the systems in the group have the same domain name suffix such as sun com Domain names are interpreted from right to left For example sun com is both the domain name of Sun Microsystems and a subdomain of the top level com domain The server that typically manages host names in a domain DNS servers translate host names such as www example com
51. CPU and memory information m Manage power remotely Power off power on power reset and power status a Manage ILOMs and BIOS Information about system ILOM firmware version and status You can also perform remote upgrades to firmware on ILOMs a Manage system boot commands and options Remote boot control via IPMI and remote mapping of boot devices and boot options m Manage remote system health checks Information about the status of a server 1 4 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 a Manage operating systems Deploy monitor and patch both Solaris and Linux operating systems m Perform bare metal discovery To learn more about this suite of powerful data center management tools go to http www sun com software products system_manager Chapter 1 ILOM and System Management Overview 1 5 1 6 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 CHAPTER 2 Connecting and Initial Setup This chapter describes how to connect to the ILOM and how to do the initial setup It contains the following sections m Section 2 1 Connecting to the ILOM on page 2 1 m Section 2 2 Configuring the ILOM IP Address on page 2 7 2 1 Connecting to the ILOM The way you connect to ILOM depends on whether it is in a rack mounted server or whether it is in a server module installed in a chassis TABLE 2 1 lists the differe
52. IPMI commands This chapter includes the following sections m Section 11 1 About IPMI on page 11 1 m Section 11 2 Supported IPMI 2 0 Commands on page 11 3 11 1 About IPMI The Intelligent Platform Management Interface IPMI is an open standard hardware management interface specification that defines a specific way for embedded management subsystems to communicate IPMI information is exchanged though baseboard management controllers BMCs which are located on IPMI compliant hardware components Using low level hardware intelligence instead of the operating system has two main benefits a It allows for out of band server management m The operating system is not burdened with transporting system status data 11 1 11 1 1 Note VMware EFX Server does not virtualize the Baseboard Management Controller BMC interface That means that guest operating systems cannot load their BMC interface drivers Also IPMI utilities cannot use the BMC interface to interact with the Service Processor When run under a guest operating system IPMI utilities must access the Service Processor over the network instead of using the BMC interface Error messages that occur when the BMC interface driver fails to load can be safely ignored Your ILOM is IPMI v2 0 compliant You can access IPMI functionality through the command line with the IPMItool utility either in band or out of band Additionally you can generate an IPMI speci
53. Roles and Setting Privileges 1 Log in to the ILOM as administrator Only accounts with administrator privileges are allowed to add modify or delete user accounts However operators can modify their own password If a new user is given administrator privileges those privileges are also automatically granted for the command line interface CLI and Intelligent Platform Management Interface IPMI to the ILOM 2 Select User Management gt User Accounts The User Accounts page appears Note The ILOM supports a maximum of nine user accounts If all nine user account slots are configured you must delete an existing user account before you can add a new user account See Section 5 3 3 Deleting User Accounts on page 5 9 5 4 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 FIGURE 5 1 User Accounts Page REFRESH LOG ouT r roc Hostnarr Sun Integrated Lights Out Manager User Management User Accounts Active Sessions LDAP Settings Radius User Settings Add delete or modify local ILOM user accounts from this page ILOM offers 10 local user accounts The system uses root which you cannot delete The other 9 are available for your use Single Sign On enables an ILOM administrator lagged in to the Chassis Monitoring Module to access any blade Service Processor without the need to log in again Single Sign On must be enabled on each Service Processo
54. SP services snmp SP services snmp communities SP services snmp communities private clear commitpending ipaddress ipdiscovery ipgateway ipnetmask linkstatus macaddress pendingipaddress pendingdiscovery pendingipgateway pendingipnetmask commitpending flowcontrol pendingspeed speed commitpending pendingspeed speed port secureredirect servicestate port servicestate ngineid port sets traps v1 v2c v3 permissions Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 TABLE A 14 Targets for the show Command Continued Valid Targets Properties SP services snmp communities public permissions SP services snmp users SP services ssh SP services ssh keys SP services ssh keys dsa fingerprint length publickey SP services ssh keys rsa fingerprint length publickey SP sessions SP sessions sessionid starttime source type user SP users SP users username role Examples gt show display properties SP users susan SP users susan Properties role Administrator TABLE A 15 gt show SP clients level 2 SP clients Targets Properties Appendix A Command Line Interface Reference A 17 TABLE A 15 SP clients ldap SP clients ntp A 2 10 Use the start command to turn on the target or to initiate a connection to the host console Syntax start A 18 options Commands cd show Targets Proper
55. SYSIPSONINOK Power Supply State Asserted ISYSIPSO PWROK Power Supply State Asserted ISYS IPSUPRSNT Entity Presence Absent JSYSIPS1VINOK Power Supply State Asserted ISYSIPS1 PWROK Power Supply State Asserted al ET en mm amp 3 Scroll down the list to find the sensor you wish to view 4 To see details about a particular sensor click its name The details view appears This view provides detailed information about the sensor such as thresholds Chapter 9 Managing the Host Using the WebGUI 9 7 FIGURE 9 5 Sample Sensor Details View Mozilla Sun Integrated Lights Out Manager View all of the properties and values for a sensor SYS MB T_AMB Property i Value type class value upper_nonrecov_threshold upper_critical_threshold upper_noncritical_threshold lower_nonrecov_threshold lower_critical_threshold Temperature Threshold Sensor 29 000 degree 45 00 degree 40 00 degree C 35 00 degree 0 00 degree C 0 00 degree C lower_noncritical_threshold 0 00 degree C Close Note The sensors shown in FIGURE 9 4 and FIGURE 9 5 are examples only The actual sensor names ranges and functions might be different on your platform For details see your platform supplement 9 4 Viewing Indicator LEDs and Controlling the Locate LED The Indicators view shows the state of the LEDs in the system 1 Log in to the ILOM as administrator or operato
56. T GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA LIMITE DE LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON OS coe Ca Adobe PostScript Contents Preface xi ILOM and System Management Overview 1 1 1 1 1 2 Introduction 1 1 1 1 1 Common Tasks That You Can Perform With ILOM 1 2 1 1 2 ILOM Default Settings 1 3 1 1 3 ILOM and Sun Blade 6000 Systems 1 4 About Sun N1 System Manager 1 4 Connecting and Initial Setup 2 1 2 1 2 2 Connecting to the ILOM 2 1 2 1 1 Connecting to the ILOM Using an Ethernet Connection 2 2 2 1 2 Connecting to the ILOM Using a Serial Connection 2 3 2 1 3 Connecting to the ILOM through the CMM 2 5 Configuring the ILOM IP Address 2 7 2 2 1 Viewing the ILOM IP Address 2 7 2 2 2 Using DHCP to Assign an IP Address 2 8 2 2 3 Configuring the IP Address Using the BIOS Setup Utility 2 9 2 2 4 Configuring the ILOM Using the CLI 2 10 2 2 5 Configuring the IP Address Using the WebGUI 2 11 3 Using the Command Line Interface 3 1 3 1 Using CLI Commands 3 1 3 1 1 CLI Namespace 3 1 3 1 2 Privilege Levels 3 2 3 1 3 CLI Command Syntax 3 2 3 1 3 1 Command Verbs 3 3 3 1 3 2 Command Options 3 3 3 1 3 3 Command Targets 3 4 3 1 3 4 Command Properties 3 4 3 2 Command Syntax 3 4 4 Using the WebGUI 4 1 4 1 Overview of WebGUI Requirements Users Tasks and Features 4
57. This namespace defines the targets for each command verb The ILOM includes two namespaces the SP namespace and the SYS namespace m The SP namespace manages the ILOM For example you use this space to manage users clock settings and other ILOM issues FIGURE 3 1 shows the SP namespace a The SYS namespace manages the host system For example you can change the host state read sensor information and access other information for managed system hardware Your SYS namespace diagram is determined by the managed hardware devices in your server 3 1 You can view your SYS namespace by typing the show SYS command from the command line FIGURE 3 1 shows the SP namespace The SYS namespace is unique to each platform FIGURE 3 1 Typical SP Namespace j f E SS j alert jsession1 isession2 commands host external i i PO irene services rules1 15 list i http https syslogs radius pate i _ a ji I A Tamers 5 en eee i commi usert i user2 i rsa j ti joa PI i servers UH 21 2 Privilege Levels The CLI provides two privilege levels administrator and operator Administrators have full access to ILOM functionality and operators have read only access to I LOM information Note The default user root has administrator privileges To create a user account with operator privileges see Chapter 5 3 1 3 CLI Command Syntax The syntax of a command is verb op
58. a system power on In UNIX operating systems the name of the superuser root The root user has permissions to access any file and carry out other operations not permitted to ordinary users Roughly equivalent to the administrator user name on Windows Server operating systems The base directory from which all other directories stem either directly or indirectly A system that assigns a path over which to send network packets or other Internet traffic Although both hosts and gateways do routing the term router commonly refers to a device that connects two networks A cryptographic algorithm developed by RSA Data Security Inc It can be used for both encryption and digital signatures Definitions that describe what type of information can be stored as entries in the directory When information that does not match the schema is stored in the directory clients attempting to access the directory might be unable to display the proper results 5 Secure Shell ssh A UNIX shell program and network protocol that enables secure and encrypted log in and execution of commands on a remote system over an insecure network Secure Sockets Layer SSL A protocol that enables client to server communication on a network to be encrypted for privacy SSL uses a key exchange method to establish an environment in which all data exchanged is encrypted with a cipher and hashed to protect it from eavesdropping and alteration SSL creates a secu
59. access to your LDAP server to search for and authenticate users Bind Password Type the password of the read only user Click Save To verify that LDAP authentication works log in to the ILOM using an LDAP user name and password Note The ILOM searches local users before LDAP users If an LDAP user name exists as a local user the ILOM uses the local account for authentication Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 CHAPTER 13 RADIUS ILOM supports Remote Authentication Dial In User Service RADIUS authentication for users based on RFC 2058 and RFC 2059 RADIUS is an authentication protocol that facilitates centralized user administration RADIUS allows many servers shared access to user data in a central database providing better security and easier administration This chapter contains the following sections m Section 13 1 RADIUS Overview on page 13 1 m Section 13 2 Configuring RADIUS Settings on page 13 2 m Section 13 3 RADIUS Commands on page 13 4 13 1 RADIUS Overview RADIUS is based on a client server model The RADIUS server provides the user authentication data and can grant or deny access and the clients send user data to the server and receive an accept or deny response A RADIUS server can work in conjunction with multiple RADIUS servers and other types of authentication servers In the RADIUS client server model the client
60. ade is complete and ILOM is reset gt load source tftp archive newmainimage Are you sure you want to load the specified file y n yY File upload is complete Firmware image verification is complete Do you want to preserve the configuration y n n Updating firmware in flash RAM Firmware update is complete ILOM will not be restarted with the new firmware Using the reset Command Use the reset command to reset the state of the target You will be prompted to confirm a reset operation Eliminate this prompt by using the script option Note The reset command does not affect the power state of hardware devices Syntax reset options target Options h help script Appendix A Command Line Interface Reference A 11 A 2 8 Targets TABLE A 12 Targets for the reset Command Valid Targets SP SYS Examples gt reset SP gt reset SYS Using the set Command Use the set command to specify the properties of the target Syntax set options default target propertyname value Options x examine h help Targets Properties and Values TABLE A 13 Targets Properties and Values for the set Command Valid Targets Properties Values SP users tusername password lt string gt role administrator operator SP alert rules rulename level disable information warnin rulename 1 through 15 g critical non recoverable destination lt ipaddress gt
61. adio button for an alert in the table 2 Select Edit from the drop down menu The Alert dialog box appears FIGURE 9 8 Alert Dialog Box Mozilla Sun Integrated Lights Out Manager To create or modify an Alert edit the IP address and select the associated level from the drop down box Click Save to complete your action IP Address 148 10 10 12 Save _ Close 3 Type the destination IP address for the alert 4 Select an event severity from the drop down menu 9 12 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 5 Click Save The modified alert appears in the Alert Destinations table 9 6 Viewing and Clearing the System Event Log This section describes how to view and clear the system event log SEL The system event log accumulates various events including administration changes to the ILOM software events and warnings and alerts It also accumulates events from the IPMI log Caution The ILOM tags all events or actions with LocalTime GMT or UDT Browser clients show these events in LocalTime This can cause apparent discrepancies in the event log When an event occurs on the ILOM the event log shows it in UDT but a client would show it as local time 1 Log in to the ILOM as administrator or operator 2 Select System Monitoring gt Event Logs The System Event Logs page appears Chapter 9 Managing the Host Using the WebGUI 9 13 FIGURE 9 9 Sy
62. age 7 16 m Section 7 10 Viewing Active Connections to the ILOM on page 7 17 7 1 Configuring the Serial Port This section describes how to configure the ILOM serial port Use this procedure only when you need to change the serial port settings The default settings are 9600 baud and no flow control The serial port provides access to the WebGUI the command line interface CLD and the system console stream using serial port redirection 7 1 m The internal serial port is the connection between the host server and the ILOM that allows an ILOM user to access the host serial console The ILOM internal serial port speed must match the speed of the serial console port on the host server often referred to as serial port 0 COM1 or dev ttySO0 Note Normally the console matches the ILOM s default settings 9600 baud 8N1 eight data bits no parity one stop bit no flow control m The external serial port is the RJ 45 serial port on the ILOM Typically the internal and external serial port connections should run at the same speed to avoid flow control issues when connecting to the host console from the ILOM external serial port 1 Log in to the ILOM as administrator 2 Select Configuration gt Serial Port The Serial Port Settings page appears 7 2 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 FIGURE 7 1 Serial Port Settings Page ABOUT REFRESH LOG OUT Role l
63. ager av Sun Microsystems inc System Information System Monitoring l Configuration User Management Remote Control Maintenance _ System Management Access Clock Settings box then type the IP addresses ofth Alert Management Network Serial Port Clock Settings Syslog To set the Service Processor clock manually type the date in the format mmidd yyyy then select the hour and minute To synchronize the Service Processor clock with an NTP server selectthe Enable check e NTP servers to use Date 10 22 1971 Time E 16 Synchronize Time Using NTP Enabled Server 1 none Server 2 none Type a date in the Date field The date format is mm dd yyyy Set the hour and minute using the drop down menus Click Save for your changes to take effect 1 oe Synchronizing the ILOM Clock with an NTP Server 1 2 Log in to the ILOM as administrator Select Configuration gt Clock Settings The Clock Settings page appears See FIGURE 7 3 Select the Enable check box next to Synchronize Time Using NTP Type the IP addresses of the NTP servers you want to use Click Save for your changes to take effect F320 Interpreting ILOM Clock Settings When the ILOM reboots the ILOM clock is set to Thu Jan 1 00 00 00 UTC 1970 The ILOM reboots as a result of the following A complete system power cycle unplugging and replugging the AC power cord Chapter 7 Managing the ILOM
64. al CD DVD drive to multiple remote servers Note You can also use this procedure to redirect a CD image file or a diskette image file stored on your hard drive 1 Start the remote console application as described in Section 10 2 Starting the Remote Console Application From the WebGUI on page 10 5 The Remote Console screen appears 2 Choose Devices gt CD ROM or Devices gt Floppy This enables the corresponding local storage device to connect to the remote server as though it were a storage device attached directly to that remote server FIGURE 10 9 CD ROM Selected J Keyboard J Mouse K CD ROM i Floppy G CD ROM Image J Floppy Image 3 To start a CD image file or a diskette image file from your hard drive select CD ROM Image or Floppy Image A browser appears Note You cannot select two CD ROM devices or two diskette devices For example you cannot select CD ROM and CD ROM image 4 Use the browser to navigate to the corresponding image file then click OK 5 To disconnect a device from the server deselect the corresponding menu item Chapter 10 Using The Remote Console Application 10 13 10 14 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 CHAPTER 1 1 Using Intelligent Platform Management Interface IPMI This chapter describes the ILOM s Intelligent Platform Management Interface IPMI functionality and lists the supported
65. anagement Remote Control Maintenance Versions Session Time Out Components Session Time out Select an inactivity time out for this session If your session is inactive for the selected time you will be logged out automatically Session Time Out 15 minutes Apply 3 From the Session Time Out drop down list select the amount of time for the session time out period 4 Click Apply A confirmation dialog box appears 5 Click OK The session timeout period is set to the selected amount of time If you exceed the amount of time set for your session you are automatically logged out of the WebGUI 7 10 Viewing Active Connections to the ILOM This section describes how to view all active connections to the ILOM 1 Log in to the ILOM as administrator or operator 2 Select User Management gt Active Sessions The Active Sessions page appears The information on this page includes the user name the date and time that the user initiated the session and the type of session web or command shell Chapter 7 Managing the ILOM Using the WebGUI 7 17 FIGURE 7 11 Active Sessions Page User Accounts Active Sessions LDAP Settings Radius Active Sessions View the users currently logged in to ILOM and the type of session they initiated ILOM supports 10 concurrent sessions of any type either web or shell User Name Start Time Type root Mon Jul 31 19 16 49 2006 web root Mon Ju
66. and Appendix A Command Line Interface Reference A 9 A 2 6 script do not prompt for yes no confirmation and act as if yes was specified Examples gt reset SYS Are you sure you want to reset SYS y n y Performing hard reset on SYS gt reset SP Are you sure you want to reset SP y n n Command aborted gt Using the load Command Use the load command to transfer an image file from a source indicated by a Uniform Resource Indicator URI to update the ILOM firmware The URI can specify a protocol and credentials used for the transfer Only the TFTP protocol is supported so the URL must begin with tftp If credentials are required and not specified the command prompts you for a password Note Use this command to update your ILOM firmware and BIOS Syntax load source URL Options h help source Examples gt load source tftp archive newmainimage gt load source tftp 10 6 22 32 tfitp files file ima gt load source tftp tftpserver sun com file ima A 10 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 A 2 7 Note A firmware upgrade will cause the server and ILOM to be reset It is recommended that a clean shutdown of the server be done prior to the upgrade procedure An upgrade takes about five minutes to complete ILOM enters a special mode to load new firmware No other tasks can be performed in ILOM until the firmware upgr
67. and Solaris are trademarks or registered trademarks of Sun Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the sat tee industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements AMD Opteron is a trademark or registered trademark of Advanced Microdevices Inc U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2007 Sun Microsystems Inc
68. and the default password is changeme FIGURE 10 4 Login Dialog Box Username root Password Bandwidth Max 10Mbps Cancel 8 Select a bandwidth from the drop down menu optional Select bandwidth that matches your actual bandwidth Note Setting the bandwidth higher than what is actually available can degrade performance Sometimes you can improve performance by setting the bandwidth lower 9 Click OK to launch the remote console application Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 When the login is successful the Remote Console screen appears FIGURE 10 5 Remote Console Screen ec y Sun ILOM Remote sole Redirection Devices Keyboard tal 10 6 154 63 The Remote Console application starts with the video and keyboard enabled Note You can open multiple Remote Console sessions and use the tabs to switch between them Chapter 10 Using The Remote Console Application 10 9 10 Choose Devices gt Mouse to enable mouse redirection Optional FIGURE 10 6 Mouse and Keyboard Redirection Selected Sun ILOM Remote Console Redirection Devices Keyboard fl 10 6 15 Keyboard Z Mouse CD ROM Floppy J CD ROM Image I Floppy Image Save as host defaults You should now be able to use the Remote Console application to start your server s operating system Video and keybo
69. apability Ethernet technology that transfers data up to 100M bits per second Fast Ethernet is backward compatible with 10M bit per second Ethernet installations A logical partition of a physical disk drive that is dedicated to a particular operating system on an x86 based system A connector that provides high bandwidth increased distance and additional connectivity from hosts to peripherals Fibre Channel Arbitrated Loop FC AL field replaceable unit FRU file system File Transfer Protocol FTP firewall firmware flash PROM fully qualified domain name FODN G gateway Gigabit Ethernet Glossary 8 A 100 Mbyte per second loop topology used with Fibre Channel that enables connection of multiple devices such as disk drives and controllers An arbitrated loop connects two or more ports but allows only two ports to communicate at a given time A system component that is replaceable at the customer site A consistent method by which information is organized and stored on physical media Different operating systems typically have different file systems File systems are often a tree structured network of files and directories with a root directory at the top and parent and child directories below root A basic Internet protocol based on Transmission Control Protocol Internet Protocol TCP IP that enables the retrieving and storing of files between systems on the Internet without regard for the op
70. ard are enabled by default In most cases all you need to do is enable the mouse redirection For detailed instructions on how to enable and disable I O and storage devices CD ROM and Diskette drives see Section 10 3 Redirecting Keyboard Video Mouse or Storage Devices on page 10 10 10 3 Redirecting Keyboard Video Mouse or Storage Devices The remote console application supports the redirection of the following types of devices m Video display the server s video output is automatically displayed on the remote console window m Keyboard and mouse devices Standard keyboards mouse and other pointing devices a Keyboard redirection is enabled by default a Mouse redirection must be enabled manually m Storage devices CD DVD drives or diskette drives 10 10 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 10 3 1 Redirecting Keyboard and Mouse Devices Use the following procedure to redirect a server keyboard and mouse device to your local workstation or laptop Note For the mouse to work correctly you might have to change the mouse mode as well This is described in Step 4 of the procedure Section 10 2 Starting the Remote Console Application From the WebGUI on page 10 5 1 Start the remote console application as described in Section 10 2 Starting the Remote Console Application From the WebGUI on page 10 5 The Remote Console screen appea
71. can also redirect diskette images img and CD ROM images iso for remote access 4 1 4 1 1 4 1 2 4 1 3 Browser and Software Requirements The WebGUI has been tested successfully with recently released Mozilla Firefox and Internet Explorer web browsers and may be compatible with other web browsers The ILOM product comes preinstalled on the Sun server However you need Java software on the client to perform redirection as described in Chapter 10 Users and Privileges After you log in to the WebGUI you can perform basic software provisioning Intelligent Platform Management Interface IPMI tasks and system monitoring ILOM user accounts include a role that defines what you can do The roles are m Administrator Enables access to all ILOM features functions and commands Operator Enables limited access to ILOM features functions and commands Operators cannot changed their assigned roles or privileges For more information on users including how to manage user accounts using the WebGUI see Chapter 5 WebGUI Tasks Some of the common tasks you can perform using the WebGUI include m Redirect the system s graphical console to a remote client browser m Connect a remote diskette drive or diskette image to the system as a virtual diskette drive m Connect a remote CD ROM drive or CD ROM image to the system as a virtual CD ROM drive m Monitor system fans temperatures and voltages remo
72. come editable when you select this option Type the ILOM s IP address The IP address is a unique name that identifies the system on a TCP IP network Type the subnet mask of the network on which the ILOM resides Type the ILOM s gateway access address Chapter 7 Managing the ILOM Using the WebGUI 7 5 4 Click Save for your settings to take effect Note Changing the IP address ends your ILOM session Settings are considered pending until you click Save You are prompted to close your web browser 5 Log back in to the ILOM using the new IP address Note If you changed the network settings you must log back in with a new browser session 7 3 TA Setting the ILOM Clock This section describes how to set the ILOM clock manually or to synchronize the ILOM date and time with a Network Time Protocol NTP server The ILOM clock is described in Section 7 3 3 Interpreting ILOM Clock Settings on page 7 7 Before you begin obtain IP addresses of the NTP servers you want to use Setting the ILOM Clock Manually 1 Log in to the ILOM as administrator 2 Select Configuration gt Clock Settings The Clock Settings page appears 7 6 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 FIGURE 7 3 Clock Settings Page Role User Administrator root SP Hostname SUNSPOO03BA84D771 Sun Integrated Lights REFRESH LOG out amp Out Man
73. d Edit Delete Community Name Permission asdfasdfasdf ro paris ro private rw public ro 2 Back to top Add Edit Delete User Name Authentication Protocol Permission Privacy Protocol alice ro dougt ro dougt2 rw michelle ro surfboards ro testuser nw 2 Back to top 14 7 2 Adding or Editing SNMP Users 1 Click the Users link or scroll down to the SNMP Users list 2 Click Add or Edit under the SNMP Users list The Add dialog box or the Edit dialog box appears See FIGURE 14 4 Chapter 14 Using Simple Network Management Protocol SNMP 14 9 FIGURE t Mozilla Sun Edit SNMP 14 4 Edit SNMP User Dialog Box Integrated Lights Out Manager user information here Click Save to confirm your changes User Name mike Authentication Protocol MD5 Authentication Password Confirm Password Permission Privacy Protocol Privacy Password Confirm Password Save Close 3 Add or change the information in the fields as follows a h Type a user name in the User Name field The name can include up to 35 characters It must start with an alphabetic character and cannot contain a space Select either Message Digest 5 MD5 or Secure Hash Algorithm SHA Type an authentication password The authentication password must contain 8 to 16 characters with no colons or space characters It is case sensitive Type the authentication pa
74. d Click OK in the dialog box The ILOM is reset This process takes about two or three minutes during which time the ILOM is unavailable Note Do not reboot the host while the ILOM is resetting itself or the host might become confused about the mouse mode For best results change the mouse mode to the desired state prior to booting the host e After the ILOM resets itself repeat Step 1 and Step 2 then proceed to Step 5 The new mouse mode is now in effect The mouse mode setting is stored on the ILOM Therefore subsequent connections to the WebGUI will use the new mode Note If you use Relative mouse mode you might have difficulty getting a redirected mouse out of the remote console window To regain control of the cursor type ALT m 5 Select the 8 bit or 16 bit color option Note For faster performance select 8 bit color 6 Click Launch Redirection The Redirection page appears Chapter 10 Using The Remote Console Application 10 7 During this procedure you might see security warnings When you are prompted select Accept Allow Yes or whatever else will tell your security software to enable the connection The JavaRConsole message appears FIGURE 10 3 JavaRConsole Page Java Web Start __ JavaRConsole Sun Microsystems Checking for latest version ee 8 7 When you see the Login dialog box type the user name and password The default user name is root
75. de for ILOM 1 1 1 May 2007 Example gt show SP clients SP clients Targets ldap ntp radius syslog Properties Commands cd show Note Users with operator privileges can only view the ntp and syslog targets The radius and ldap targets remain hidden Chapter 13 RADIUS 13 7 13 8 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 14 Using Simple Network Management Protocol SNMP This chapter describes how to use SNMP It includes the following sections m Section 14 1 About SNMP on page 14 1 m Section 14 2 SNMP Management Information Base MIB Files on page 14 2 m Section 14 3 MIBs Integration on page 14 3 m Section 14 4 About SNMP Messages on page 14 3 m Section 14 5 About ILOM and SNMP on page 14 4 m Section 14 6 Managing SNMP Users With the CLI on page 14 5 m Section 14 7 Managing SNMP With the WebGUI on page 14 7 14 1 14 1 1 About SNMP The Sun server supports the Simple Network Management Protocol SNMP interface versions 1 2c and 3 SNMP is an open technology that enables the management of networks and devices or nodes connected to the network SNMP messages are sent over IP using the User Datagram Protocol UDP Any management application that supports SNMP can manage your server How SNMP Works Utilizing SNMP requires two components a network management stati
76. des the following components Service Processor SP This is the hardware It consists of a dedicated processor board that communicates through the system serial port and a dedicated Ethernet port Command Line Interface CLI The command line interface is a dedicated software application that allows you to operate the ILOM using keyboard commands You can use the command line interface to send commands to the ILOM You can connect a terminal or emulator directly to the system serial port or connect over the Ethernet using a secure shell ssh To log in to and use the CLI see Chapter 3 WebGUI The WebGUI provides a powerful yet easy to use browser interface that allows you to log in to the SP and perform system management monitoring and IPMI tasks For instructions on how to use the WebGUI see Chapter 4 1 1 1 Remote Console Java Client The Java Client supports the Remote Console functionality which allows you to access your server s console remotely It redirects the keyboard mouse and video screen and can redirect input and output from the local machine s CD and diskette drives For instructions on how to use the remote console see Chapter 10 You do not need to install additional hardware or software to begin managing your server with ILOM ILOM also supports industry standard IPMI and SNMP management interfaces Intelligent Platform Management Interface IPMI v2 0 Using a secure shell ssh
77. e For changes to the SC SP s state e g initializing to master e Chassis Action Category for shutdown events for server module chassis hot insert removal of a FRU and reset parameters button pushed e FMA Fault For FMA faults Description gives time of fault as detected by FMA and suspect component e FMA Repair For FMA repairs Description gives component Severity Critical Major or Minor Date Time The day and time the event occurred If the Network Time Protocol NTP server is enabled to set the ILOM time the ILOM clock will use Universal Coordinated Time UTC Description A description of the event 5 To clear the event log click Clear Event Log A confirmation dialog box appears Note The SEL accumulates many types of events including copies of entries that IPMI posts the IPMI log Clearing the SEL clears all entries including the copies of the IPMI log entries However clearing the SEL does NOT clear the actual IPMI log You must use IPMI commands to view and clear the IPMI log 6 Click OK to clear all entries in the log Interpreting the System Event Log SEL Time Stamps The SEL time stamps are related to the ILOM clock settings If the clock settings change the change is reflected in the time stamps Chapter 9 Managing the Host Using the WebGUI 9 15 When the ILOM reboots the ILOM clock is set to Thu Jan 1 00 00 00 UTC 1970 The ILOM reboots as a result of the following
78. e settings currently in use by the ILOM These settings are read only If you want to change settings enter the updated settings as the pending settings then set the commitpending property to true This prevents accidental disconnections for both port and network settings 6 1 2 1 Syntax set target propertyname value 6 1 2 2 Targets Properties and Values The following targets properties and values are valid for ILOM serial ports TABLE6 1 Valid Targets Properties and Values for ILOM Serial Ports Target Property Value Default SP serial external commitpending true none none flowcontrol none none pendingspeed lt decimal gt 9600 speed 9600 9600 SP serial host commitpending true none none pendingspeed lt decimal gt none speed 9600 9600 Example To change the speed baud rate for the host serial port from 9600 to 57600 type gt set SP serial host pendingspeed 57600 commitpending true 6 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 Note The speed of the host serial port must match the speed setting for serial port 0 COM1 or dev ttys0 on the host operating system for the ILOM to communicate properly with the host 6 2 6 2 1 6 2 2 6 2 2 1 Configuring ILOM Network Settings You can display or configure the ILOM network settings from the CLI Displaying Network Settings Type the following command to display network setting
79. e WebGUI m Refresh button Click to refresh the information in the content area of the page The Refresh button does not save new data that you may have entered or selected on the page Use the Save button that is provided in the content area for a specific WebGUI page Note Do not use the Refresh button from your web browser when you are using the WebGUI Log Out button Click to end the current session of the WebGUI You are directed to the logout screen m About button Click to view copyright information m User field Displays the user name of the current user of the WebGUI m Server field Displays the name of the ILOM The navigation bar provides tabs that you can click to open a specific WebGUI page When you click a main tab subcategories of tabs are displayed providing you with further options to choose Select the tabs to open the appropriate WebGUI pages Chapter 4 Using the WebGUI 4 3 The content area of the WebGUI page is where you find information about the specific topic or operation you chose using the tabs The content area displays such things as logs status indicators task wizards and command buttons to execute an operation 4 2 4 4 Logging In to the WebGUI This section describes how to log in to and out of the WebGUI Note The ILOM boots automatically when a Sun server is cabled appropriately and plugged in to an AC supply or when a server module is inserted into a
80. e command for the current target and all targets contained through the level specified Chapter 3 Using the Command Line Interface 3 3 3 1 3 3 3 1 3 4 TABLE 3 2 Command Options Continued Option Long Form Short Form Description output 0 Specifies the content and form of command output script Skips warnings or prompts normally associated with the command source Indicates the location of a source image Command Targets Every object in your namespace is a target Not all targets are supported for all commands Section A 2 CLI Command Reference on page A 6 lists each command with its targets and properties Command Properties Properties are the configurable attributes specific to each object An object can have one or more properties Section A 2 CLI Command Reference on page A 6 lists each command with its targets and properties 32 Command Syntax To execute most commands you need to specify the location of the target then enter the command You can execute commands individually or you can combine them on the same command line 1 To execute commands individually a Navigate to the namespace using the CD command For example cd SP services http b Enter the verb target and value For example set port 80 3 4 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 2 To combine commands use the form verb path target value For e
81. e scrollbar to view the list 4 To toggle the state of the locate LED a Click the radio button next to SYS LOCATE b Select a state from the drop down menu The states are Turn LED Off or Set LED to Fast Blink A dialog asks you to confirm c Click OK The locate LED changes states and the new state appears in the Status column Chapter 9 Managing the Host Using the WebGUI 9 9 9 5 9 5 1 Managing Alerts This section describes how to view alert destinations and configure alert settings for the ILOM The alert management view allows you to map alert levels to destinations IP addresses For example you can configure it so that all critical alerts are sent to one destination and all non recoverable alerts are sent to another An alert is generated when a sensor crosses the specified threshold For example if you configure an alert for critical thresholds the ILOM sends an IPMI trap to the specified destination when any sensor crosses the upper or lower critical CT threshold A special criteria informational is reserved for system events that are not related to sensors The mapping between alert levels and sensors is TABLE 9 1 Mapping between Alerts and Sensors Alert Sensor Warning Upper non critical lower non critical Critical Upper critical lower critical Non recoverable Upper non recoverable lower non recoverable Informational System events not related to sensors All alerts are IPMI PET t
82. e system resets and power on and off capabilities and alerting Internet Control Message Protocol ICMP An extension to the Internet Protocol IP that provides for routing reliability flow control and sequencing of data ICMP specifies error and control messages used with the IP Internet Protocol IP The basic network layer protocol of the Internet IP enables the unreliable delivery of individual packets from one host to another IP does not guarantee that the packet will be delivered how long it will take or if multiple packets will be delivered in the order they were sent Protocols layered on top of IP add connection reliability Internet Protocol IP address In Transmission Control Protocol Internet Protocol TCP IP a unique 32 bit number that identifies each host or other hardware system on a network The IP address is a set of numbers separated by dots such as 192 168 255 256 which specifies the actual location of a machine on an intranet or the Internet interrupt request IRQ A signal that a device requires attention from the processor Glossary 10 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 IPMItool J Java Web Start application JumpStart installation K kernel Keyboard Controller Style KCS interface keyboard video mouse storage KVMS Glossary 11 A utility used to manage IPMI enabled devices IPMItool can manage IPMI functions of
83. ebGUI 9 1 9 1 Controlling Power to the Host Server 9 1 9 2 Viewing Replaceable Component Information 9 2 Hot Swappable and Hot Pluggable Components 9 2 9 3 Viewing Sensors 9 5 9 4 Viewing Indicator LEDs and Controlling the Locate LED 9 8 9 5 Managing Alerts 9 10 9 5 1 Viewing Alert Destinations 9 10 9 5 2 Configuring an Alert 9 12 9 6 Viewing and Clearing the System Event Log 9 13 9 6 1 Interpreting the System Event Log SEL Time Stamps 9 15 9 7 Viewing ILOM Hardware Firmware and IPMI Versions 9 17 Using The Remote Console Application 10 1 10 1 About the Remote Console Application 10 1 10 1 1 Installation Requirements 10 2 10 1 2 CD and Diskette Redirection Operational Model 10 3 10 1 3 Remote Console Security 10 5 10 2 Starting the Remote Console Application From the WebGUI 10 5 10 3 Redirecting Keyboard Video Mouse or Storage Devices 10 10 10 3 1 Redirecting Keyboard and Mouse Devices 10 11 10 3 2 Redirecting Storage Devices 10 13 Using Intelligent Platform Management Interface IPMI 11 1 11 1 AboutIPMI 11 1 11 1 1 IPMItool 11 2 11 2 Supported IPMI 2 0 Commands 11 3 Contents vii 12 Lightweight Directory Access Protocol LDAP 12 1 12 1 LDAP Servers Directory Organization 12 1 12 2 LDAP Clients and Servers 12 2 12 3 Configuring LDAP 12 3 12 3 1 Configuring the LDAP Server 12 4 12 3 2 Configuring the LOM 12 4 12 3 2 1 Configuring the ILOM Using the CLI 12 5 12 3 2 2 Configuring the ILOM Using the WebGUI 12 5 13 RADIUS
84. either the local system or a remote system Functions include managing field replaceable unit FRU information local area network LAN configurations sensor readings and remote system power control A web application launcher With Java Web Start applications are launched by clicking on the web link If the application is not present on your system Java Web Start downloads it and caches it onto your system Once an application is downloaded to its cache it can be launched from a desktop icon or browser link The most current version of the application is always presented A type of installation in which the Solaris software is automatically installed on a system by using the factory installed JumpStart software The core of the operating system OS that manages the hardware and provides fundamental services such as filing and resource allocation that the hardware does not provide A type of interface implemented in legacy personal computer PC keyboard controllers Data is transferred across the KCS interface using a per byte handshake A series of interfaces that enables a system to respond to keyboard video mouse and storage events L lights out management LOM Lightweight Directory Access Protocol LDAP Lightweight Directory Access Protocol LDAP server Linux Loader LILO local area network LAN local host M major event Management Information Base MIB man pages Glossary 12
85. ement stations and agents use SNMP messages to communicate Management stations can send and receive information Agents can respond to requests and send unsolicited messages in the form of a trap There are five functions that management stations and agents use m Get m GetNext m GetResponse m Set m Trap By default port 161 is used for SNMP messages and port 162 is used to listen for SNMP traps 14 5 14 5 1 14 5 2 About ILOM and SNMP The ILOM has a preinstalled SNMP agent that supports trap delivery to an SNMP management application To use this feature you must 1 integrate the platform specific MIBs into your SNMP environment 2 tell your management station about your server and 3 configure the specific traps The Sun server MIB tree appears in FIGURE 14 1 Integrating the MIBs Use a third party SNMP management application to load the SUN PLATFORM MIB listed in Section 14 2 SNMP Management Information Base MIB Files on page 14 2 Adding Your Server to Your SNMP Environment Add your Sun server as a managed node using your SNMP management application See your SNMP management application documentation for more details 14 4 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 14 5 3 Configuring Receipt of SNMP Traps To configure a trap in your ILOM see Section 8 5 Managing ILOM Alerts on page 8 6 for CLI instructions and Section 9 5 Managing
86. ems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation pepe Xerox cette licence couvrant galement les licenci es de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun AMD Opteron est une marque de fabrique ou une marque deposee de Advanced Microdevices Inc LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS E
87. ents radius Targets Properties defaultrole Operator ipaddress 129 144 36 142 port 1812 secret none state enabled Commands cd set show set SP clients radius This command is available to administrators Purpose Use this command to configure the properties associated with RADIUS authentication on a service processor Syntax set SP clients radius defaultrole Administrator Operator ipaddress radiusserverIP port port secret radiussecret state enabled disabled Chapter 13 RADIUS 13 5 13 3 3 Properties a defaultrole Assign a permission level that will apply to all RADIUS users m ipaddress The IP address of your RADIUS server m port The port number used to communicate with your RADIUS server The default port is 1812 m secret Enter the shared secret used to gain access to your RADIUS server This is also known as an encryption key m state Choose enabled or disabled to allow or deny access to your RADIUS users Example gt set SP clients radius state enabled ipaddress 10 8 145 77 Set state to enabled Set ipaddress to 10 8 145 77 show SP clients This command is available to administrators and operators Purpose Use this command to view clients that can receive data from a service processor including LDAP NTP RADIUS and SYSLOG clients Syntax show SP clients 13 6 Integrated Lights Out Manager ILOM Administration Gui
88. erable lower non recoverable Informational System events not related to sensors Displaying Alerts m Type the following command to display alerts show SP alert rules m Type the following to display information about a single alert show SP alert rules N where N is 1 to 15 Configuring Alerts Use the set command to change properties and values for alerts Syntax set target propertyname value Targets Properties and Values The following targets properties and values are valid for IPMI PET alerts TABLE 8 2 Valid Targets Properties and Values for IPMI Pet Alerts Target Property Value Default SP alert rules 1 15 destination lt ipaddress gt none level disable information warning disabl critical non recoverable e Chapter 8 Managing the Host Using the CLI 8 7 8 5 3 The parameters are m rule The number of the alert rule a number from 1 to 15 m ipaddress The IP address to which the alert will be sent m level The severity level of the alert see TABLE 8 3 TABLE 8 3 Alert Levels Name in Sensor Alert Levels Readings View Description informational N A This level traps system events that are not related to sensors such as The host has booted warning NC The sensor is outside of its normal range but not critical critical CT The sensor has crossed a critical threshold non recoverable NR The sensor has reached a threshold beyond the tolerance level of the corre
89. erating systems or architectures of the systems involved in the file transfer A network configuration usually both hardware and software that protects networked computers within an organization from outside access A firewall can monitor or prohibit connections to and from specified services or hosts Software that is typically used to help with the initial booting stage of a system and with system management Firmware is embedded in read only memory ROM or programmable ROM PROM A programmable read only memory PROM that can be reprogrammed while installed within the system from software on a disk by a voltage pulse or by a flash of light The complete and unique Internet name of a system such as www sun com The FQDN includes a host server name www and its top level com and second level sun domain names A FQDN can be mapped to a system s Internet Protocol IP address A computer or program that interconnects two networks and then passes data packets between the networks A gateway has more than one network interface Ethernet technology that transfers data up to 1000M bits per second Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Grand Unified Bootloader GRUB graphical user interface GUI H heatsink host host ID host name hot plug hot swap Hypertext Transfer Protocol HTTP Hypertext Transfer Protocol Secure HTTPS Glossary 9 A
90. ers are assigned portions of the tree structure to which they may attach descriptions that are specific to their own devices Online UNIX documentation Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 media access control MAC address Message Digest 5 MD5 minor event N namespace Network File System NFS Network Information Service NIS network interface card NIC network management station NMS network mask Network Time Protocol NTP node nonmaskable interrupt NMI Glossary 13 Worldwide unique 48 bit hardware address number that is programmed in to each local area network interface card NIC at the time of manufacture A secure hashing function that converts an arbitrarily long data string into a short digest of data that is unique and of fixed size A system event that does not currently impair service but which needs correction before it becomes more severe In the tree structure of a Lightweight Directory Access Protocol LDAP directory a set of unique names from which an object name is derived and understood For example files are named within the file namespace and printers are named within the printer namespace A protocol that enables disparate hardware configurations to function together transparently A system of programs and data files that UNIX systems use to collect collate and share specific information about machines users
91. ersion The current ILOM version show SP cli commands All the CLI commands show SP sessions All active sessions help targets Available valid targets Chapter 6 Managing the ILOM Using the CLI 6 11 6 9 1 6 9 2 6 12 Displaying Version Information Type the following command to display the current ILOM version version For example SP SP SP SP version firmware 1 1 1 firmware build number r14021 firmware date Fri Oct 13 21 18 44 PDT 2006 filesystem version 0 1 14 Displaying Available Targets Type the following command to display the available valid targets help targets Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 7 Managing the ILOM Using the WebGUI This chapter describes how to use the WebGUI to perform monitoring and maintenance It includes the following sections m Section 7 1 Configuring the Serial Port on page 7 1 m Section 7 2 Configuring ILOM Network Settings on page 7 3 m Section 7 3 Setting the ILOM Clock on page 7 6 m Section 7 4 Resetting the ILOM on page 7 9 m Section 7 5 Resetting the ILOM and BIOS Passwords on page 7 9 m Section 7 6 Upgrading the ILOM Firmware on page 7 10 m Section 7 7 Enabling HTTP or HTTPS Web Access on page 7 13 m Section 7 8 Uploading a New SSL Certificate on page 7 15 m Section 7 9 Setting the ILOM Session Timeout Period on p
92. es a command to connect to the server module ILOM This connection requires a terminal or a PC running terminal emulation software to the RJ 45 serial port on the chassis This section applies only to systems that meet the following requirements The server module must be installed in a chassis equipped with a Chassis Management Module CMM ILOM See the chassis documentation for additional details The server module must be equipped with an ILOM Some server modules have different service processors See the server module documentation for additional details Verify that your terminal laptop or terminal server is operational Configure that terminal device or the terminal emulation software to use the following settings 8N1 eight data bits no parity one stop bit 9600 baud default can be set to any standard rate up to 57600 Disable software flow control XON XOFF Connect a serial cable from the serial port on the chassis to a terminal device Refer to the chassis documentation for the location of the serial port Press Enter on the terminal device This establishes the connection between the terminal device and the CMM ILOM The CMM ILOM displays its login prompt SUNCMMnnnnnnnnnnN login The first string in the prompt is the default host name It consists of the prefix SUNCMM and the CMM ILOM s MAC address The MAC address for each service processor is unique Chapter 2 Connecting and Initial Setup 2 5 5 L
93. eys rsa key settings TABLE A 7 SNMP Commands Description Command Display information about show SP services snmp engineid snmpengineid SNMP settings By default port snmpportnumber sets enabled disabled the SNMP port is 161 and v3 vl enabled disabled v2e enabled disabled is enabled v3 enabled disabled Display SNMP users show SP services snmp users Add an SNMP user create SP services snmp users snmpusername authenticat ionpassword password authenticationprotocol MD5 SHA permissions rw ro privacypassword password privacyprotocol none DES Delete an SNMP user delete SP services snmp users snmpusername Display information about show SP services snmp communities public SNMP public read only communities A 4 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 TABLE A 7 SNMP Commands Continued Description Command Add this device to an SNMP create SP services snmp communities public community public comm1 Delete this device from an delete SP services snmp communities SNMP public community public comm1 Display information about show SP services snmp communities private SNMP private read write communities Add this device to an SNMP create SP services snmp communities private community private comm2 Delete this device from an delete SP services snmp communities SNMP private community private comm2 TABLE A 8 Host System Commands Description
94. f 450M bits per second USB 2 0 A USB port connects devices such as mouse pointers keyboards modems and printers to the computer system Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 unshielded twisted pair shielded twisted pair UTP STP user account User Datagram Protocol UDP user identification userid user identification number UID number user name V voltage regulator module VRM volume volume manager W3C Glossary 21 A type of Ethernet cable A record of essential user information that is stored on the system Each user who accesses a system has a user account A connectionless transport layer protocol that adds some reliability and multiplexing to the Internet Protocol IP UDP enables one application program to deliver via IP datagrams to another application program on another machine The Simple Network Management Protocol SNMP is usually implemented over UDP A unique string identifying a user to a system The number assigned to each user accessing a UNIX system The system uses UID numbers to identify by number the owners of files and directories A combination of letters and possibly numbers that identifies a user to the system An electronic device that regulates a system s microprocessor voltage requirements in order to maintain the correct voltage One or more disk drives that can be grouped into a unit for data storage
95. fic trap from the web interface or manage the server s IPMI functions from any external management solution that is IPMI v1 5 or v2 0 compliant For more information about the IPMI v2 0 specification go to http www intel com design servers ipmi spec htm spec2 Note Your server includes a number of IPMI compliant sensors that measure things such as voltages temperature ranges and security latches that detect when the enclosure is opened For a complete list of sensors see your platform supplement Caution Do not use any interface other than the ILOM CLI or WebGUI to alter the state or configuration of any sensor or LED Doing so could void your warranty IPMItool IPMItool is a simple command line interface that is useful for managing IPMI enabled devices You can use this utility to perform IPMI functions with a kernel device driver or over a LAN interface IPMItool enables you to manage system field replaceable units FRUs monitor system health and monitor and manage the system environment independent of the operating system You can download IPMItool from http ipmitool sourceforge net Also a copy of IMPItool and its related documentation is provided on your server Tools and Drivers CD When IPMItool is installed it includes a man page To view it type man ipmitool 11 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 11 2 Supported IPMI 2 0 Commands
96. g its own CD and diskette drives 10 1 10 1 1 Installation Requirements You do not need to install software on the host system server The ILOM ships with the remote console application installed A compatible web browser and JRE 1 5 are required to operate the remote console application See TABLE 10 1 You do not need to install any OS specific drivers or helper applications on client systems to run the remote console application TABLE 10 1 Client Installation Requirements Java Runtime Environment Client OS Including Java Web Start Browser s Microsoft Windows XP Pro JRE 1 5 Java 5 0 Internet Explorer 6 0 and later Mozilla 1 7 5 or later Mozilla Firefox 1 0 Red Hat Linux 3 0 and 4 0 Desktop JRE 1 5 Java 5 0 Mozilla 1 7 5 or later and Workstation Editions Mozilla Firefox 1 0 Solaris 9 JRE 1 5 Java 5 0 Mozilla 1 7 5 Solaris 10 JRE 1 5 Java 5 0 Mozilla 1 7 5 SUSE Linux 9 2 JRE 1 5 Java 5 0 Mozilla 1 7 5 Note To download the Java 1 5 runtime environment go to http java com The remote console application uses the following TCP ports TABLE 10 2 Remote Console Ports and Interfaces Port Interface Application 443 TCP HTTPS 5120 TCP Remote CD 5121 TCP Remote keyboard and mouse 5123 TCP Remote diskette 6577 TCP CURI API TCP and SSL 10 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 TABLE 10 2 Remote Console Ports and Interfaces C
97. hcp static dhcp pendingipgateway lt ipaddress none gt none pendingipnetmask lt ipdotteddecimal gt 255 255 255 255 Examples To change the IP address for the ILOM type gt set SP network ipaddress nnn nn nn nn commitpending true Note Changing the IP address disconnects your active session if you are connected to the ILOM via a network To change the network settings from DHCP to static assigned settings type gt set SP network pendingipdiscovery static pendingipaddress nnn nn nn nn pendingipgateway nnn nn nn nn pendingipnetmask nnn nn nn nn commitpending true 6 3 6 3 1 6 3 2 6 3 2 1 6 3 2 2 Setting the ILOM Clock You can display clock settings or configure your clock to synchronize with one or two Network Time Protocol NTP servers If you do not configure an NTP server the time is set by the system BIOS Displaying Clock Settings Type the following command to display clock settings show SP clock Configuring the Clock to Use NTP Servers Use the set command to change properties and values for NTP servers Syntax set target propertyname value Targets Properties and Values The following targets properties and values are valid for NTP servers TABLE 6 3 Valid Targets Properties and Values for NTP Servers Target Property Value Default SP clients ntp server 1 address ipaddress none SP clients ntp server 2 address ipaddress none Example To conf
98. he following SNMP classes of MIB files Standard a SNMP FRAMEWORK MIB a SNMP USER BASED MIB a SNMP MPD MIB a ENTITY MIB Sun Specific a SUN PLATFORM MIB a SUN ILOM CONTROL MIB a SUN ILOM PET MIB Download and install the product specific MIB files from your Tools and Drivers CD for your platform 14 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 14 3 MAIBs Integration Use the MIBs to integrate the management and monitoring of the server into SNMP management consoles The MIB branch is a private enterprise MIB located at MIB object iso 1 org 3 dod 6 internet 1 private 4 enterprises 1 sun 42 products 2 FIGURE 14 1 shows the arrangement The standard SNMP port port 161 is used by the SNMP agent on the ILOM FIGURE 14 1 Sun server MIB Tree B C MIB Tree C ccitt iso E ca org 3 dod E TREE internet C directory experimental C mgmt 0 private enterprises fa sun EI products E 9 SunFire C SunPlatMIB security snmp 2 14 4 About SNMP Messages SNMP is a protocol not an operating system so you need some type of application to use SNMP messages Your SNMP management software might provide this functionality or you can use an open source tool like net SNMP which is available at http net snmp sourceforge net Chapter 14 Using Simple Network Management Protocol SNMP 14 3 Both manag
99. hts Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 A 2 2 A 2 3 Using the create Command Use the create command to set up an object in the namespace Unless you specify properties with the create command they are empty Syntax create options target propertyname value Options d default h help Targets Properties and Values TABLE A 10 Targets Properties and Values for the create Command Valid Targets Properties Values Default SP users username password lt string gt none role administrator operator operator SP services snmp community permissions rolrw ro communityname SP services snmp user authenticationprotocol MD5 MD5 username authenticationpassword lt string gt null string permissions rolrw ro privacyprotocol none DES DES privacypassword lt string gt null string Example gt create SP users susan role administrator Using the delete Command Use the delete command to remove an object from the namespace You will be prompted to confirm a delete command Eliminate this prompt by using the script option Appendix A Command Line Interface Reference A 7 Syntax delete options script target Options force h help script Targets TABLE A 11 Targets for the delete Command Valid Targets SP users username SP services snmp community communityname SP services snmp user username Examples gt delete SP users susa
100. iew the version of ILOM firmware currently in use Version Information Property Value SP Firmware Version LES SP Firmware Build Number r14021 SP Firmware Date Fri Oct 13 21 18 44 PDT 2006 SP Filesystem Version 0 1 14 Chapter 9 Managing the Host Using the WebGUI 9 17 9 18 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 10 Using The Remote Console Application This chapter describes how to use the remote console application It includes the following sections 10 1 Section 10 1 About the Remote Console Application on page 10 1 Section 10 2 Starting the Remote Console Application From the WebGUI on page 10 5 Section 10 3 Redirecting Keyboard Video Mouse or Storage Devices on page 10 10 About the Remote Console Application The remote console application which is started using the WebGUI allows you to control your server s operating system remotely using the screen mouse and keyboard and to redirect local CD and diskette drives as if they were connected directly to the server The screen mouse and keyboard functionality allows you to use the operating system and other GUI based programs instead of restricting you to the command line based utilities provided by terminals and emulators The ability to redirect CD and diskette drives allows you to download and upload software to and from the server as if you were accessin
101. igure your clock to synchronize with an NTP server type gt set SP clients ntp server 1 address 125 128 84 20 Then enable the NTP service by typing Chapter 6 Managing the ILOM Using the CLI 6 5 6 3 3 gt set SP clock usentpserver enabled Note Once you enable the NTP service it can take up to five minutes for the clock to synchronize Interpreting ILOM Clock Settings When the ILOM reboots the ILOM clock is set to Thu Jan 1 00 00 00 UTC 1970 The ILOM reboots as a result of the following m A complete system unplug replug power cycle a An IPMI command for example me reset cold A command line interface CLI command for example reset SP m WebGUI operation for example from the Maintenance tab select Reset SP a An ILOM firmware upgrade Note Log event timestamps might appear different between host and client systems because of time zone adjustment The timestamps on events reported in the server s system event log and IPMI logs are always based on GMT UTC However when you view system information from a client system using the GUI or IPMItool the timestamps displayed are adjusted based on the time zone of the client system Therefore the same event can appear to have two different timestamps when viewed directly from the host and from a client system in a different time zone After an ILOM reboot the ILOM clock is changed by the following m When the host is booted The host s BIOS
102. ion Active Callback Set Get User Callback Options Event Commands Get Event Count Set Get Event Destination Set Get Event Reception State Send ICMB Event Message 11 6 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 12 Lightweight Directory Access Protocol LDAP The ILOM supports LDAP authentication for users based on the OpenLDAP software LDAP is a general purpose directory service A directory service is a centralized database for distributed applications designed to manage the entries in a directory Thus multiple applications can share a single user database For more detailed information on LDAP go to http www openldap org LDAP is based on a client server model LDAP provides the directory and the clients use the directory service to access entries The data stored in a directory can be distributed among several LDAP servers This chapter includes the following sections m Section 12 1 LDAP Servers Directory Organization on page 12 1 m Section 12 2 LDAP Clients and Servers on page 12 2 m Section 12 3 Configuring LDAP on page 12 3 12 1 LDAP Servers Directory Organization Data in LDAP is organized hierarchically starting at a root and branching down into individual entries Entries at the top level of the hierarchy represent larger organizations and under the larger organizations are entries for smaller organizations At the bottom
103. ion dial in user service B 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 Glossary The following terms are used within the Sun server documentation A access control list ACL address address resolution Address Resolution Protocol ARP Administrator Advanced Configuration and Power Interface ACPI A software authorization mechanism that enables you to control which users have access to a server Users can define ACL rules that are specific to a particular file or directory granting or denying access to one or more users or groups In networking a unique code that identifies a node in the network Names such as host1l sun com are translated to dotted quad addresses such as 168 124 3 4 by the Domain Name Service DNS A means for mapping Internet addresses into physical media access control MAC addresses or domain addresses A protocol used to associate an Internet Protocol IP address with a network hardware address MAC address The person with full access root privileges to the managed host system An open industry specification that provides power management capabilities to a system that enable the operating system to determine when peripheral devices are idle and to utilize ACPI defined mechanisms for putting the devices into low power modes The ACPI specification also describes a large number of power states for CPUs devices and systems as
104. ionpassword string null string permissions rolrw ro privacyprotocol none DES none privacypassword string null string SP services snmp engineid none string null string port 161 integer 161 sets enabled enabled disabled disabled v1 disabled enabled disabled disabled v2c disabled enabled disabled disabled v3 disabled enabled disabled enabled If the privacyprotocol property has a value other than none then a privacypassword must be set 14 6 3 3 Examples When changing the parameters of SNMP users you must set values for all the properties even if you are not changing all the values For example to change user jeff s privacyprotocol to DES you must type gt set SP services snmp users jeff privacyprotocol DES privacypassword password authenticationprotocol SHA authenticationpassword password Your changes would be invalid if you typed gt set SP services snmp users jeff privacyprotocol DES 14 6 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 Note You can change SNMP user permissions without resetting the privacy and authentication properties 14 7 Managing SNMP With the WebGUI This section describes how to use the WebGUI to manage SNMP users For more information about SNMP and the classes of MIB files that the Sun server supports see Section 14 1 About SNMP on page 14 1 14 7 1 Configuring SNMP Settings 1 Log in to the ILOM
105. l 31 19 26 52 2006 shell 7 18 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 e May 2007 CHAPTER 8 Managing the Host Using the CLI This chapter describes how to use the ILOM s command line interface CLI to manage the host The sections include m Section 8 1 Controlling Power to the Host Server on page 8 1 m Section 8 2 Starting and Stopping the Host Console on page 8 2 m Section 8 3 Viewing System Components Indicators and Sensors on page 8 2 m Section 8 4 Setting the Locate LED on page 8 6 m Section 8 5 Managing ILOM Alerts on page 8 6 m Section 8 6 Viewing and Clearing Event Logs on page 8 9 8 1 Controlling Power to the Host Server a To power on the host type start SYS To power off the host type stop SYS m To reset the host type reset SYS Note Entering reset SYS does not affect the power state of the host m To send a break to the host type Escape B press the Escape key and type upper case B 8 1 8 2 Starting and Stopping the Host Console m Type the start command to start a session to the server console start SP console m Type the stop command to terminate a server console session started by another user stop SP console Note Before connecting to the console the ILOM must be set to its default settings 9600 baud 8N1 eight data bits no parity one stop bit no flow control
106. lt Role defaultrole Sets the default role for all RADIUS users administrator operator administrator or operator IP Address ipaddress ipaddress The IP address of the RADIUS server Port port portnum The port number used to communicate with the RADIUS server The default port is 1812 Chapter 13 RADIUS 13 3 TABLE 13 1 RADIUS WebGUI and CLI Settings WebGUI CLI Description State state enabled disabled Enable to authenticate RADIUS users Encryption Key Type the encryption key used by your RADIUS server secret text The shared secret used to gain access to RADIUS 13 3 RADIUS Commands This section describes the RADIUS commands 13 3 1 show SP clients radius This command is available to administrators and operators Purpose Use this command to view the properties associated with RADIUS authentication Syntax show SP clients radius Properties defaultrole This is the role assigned to all RADIUS users It is either administrator or operator ipaddress The IP address of your RADIUS server port The port number used to communicate with your RADIUS server The default port is 1812 secret Enter the shared secret used to gain access to your RADIUS server 13 4 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 L3 32 state Choose enabled or disabled to allow or deny access to your RADIUS users Example gt show SP clients radius SP cli
107. mber so that an OID is a sequence of numbers In Internet usage the OID numbers are delimited by dots for example 0 128 45 12 In the Lightweight Directory Access Protocol LDAP OIDs are used to uniquely identify schema elements including object classes and attribute types A layer of software that takes control of an initialized system after the power on self test POST successfully tests components OpenBoot PROM builds data structures in memory and boots the operating system An operating system independent event driven library for simplifying access to the Intelligent Platform Management Interface IPMI A user with limited privileges to the managed host system Server management capability that is enabled when the operating system network drivers or the server are not functioning properly A method used by a computer for checking that data received matches data sent Also refers to information stored with data on a disk that enables the controller to rebuild data after a drive failure A physical section on a hard disk drive A local bus standard used to connect peripherals to 32 bit or 64 bit systems An integrated circuit that controls peripherals in an interrupt request IRQ driven system taking away that load from the central processing unit CPU Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 permissions physical address Platform Event Filtering PEF Platform
108. n gt delete script SP alert rules tojohn A 2 4 Using the exit Command Use the exit command to terminate a session to the CLI Syntax exit options Options h help A 8 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 A 2 5 Using the help Command Use the help command to display Help information about commands and targets Using the output terse option displays usage information only The output verbose option displays usage description and additional information including examples of command usage If you do not use the output option usage information and a brief description of the command are displayed Specifying command targets displays a complete list of valid targets for that command from the fixed targets in SP and SYS Fixed targets are targets that cannot be created by a user Specifying command targets legal displays copyright information and product use rights Syntax help options command targets Options h help output terse verbose Commands cd create delete exit help load reset set show start stop version Examples gt help load The load command is used to transfer a file from a server to a target Usage load source URL target source specify the location to get a file gt help output verbose reset The reset command is used to reset a target Usage reset script target Available options for this comm
109. nents Some components are hot swappable meaning that you can remove them from the system without warning or preparation 9 2 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Other components are hot pluggable meaning that they can be removed while the system is running but the system must be prepared first Some hot pluggable components can be prepared for removal using the Components Management page Those components display a radio button in the left hand column of the Component Management page FIGURE 9 2 Still other components require the system to be shut down before they can be removed Note The data shown in FIGURE 9 2 and FIGURE 9 3 are examples only The actual data you see might be different on your platform For details see your platform supplement 1 Log in to the ILOM as administrator or operator 2 Select System Information gt Components The Component Management page appears Chapter 9 Managing the Host Using the WebGUI 9 3 FIGURE 9 2 Sample Repleacable Component Page REFRESH LOG OUT r Administrato SPH Sun Integrated Lights Out Manager System Information Versions Session Time Out Components Component Management View component details or prepare to install or remove a component from this page To modify a component select the radio button next to that component then choose an option from the Action drop down list Comp
110. nt connection methods and their relevance to rack mounted servers and server modules in a chassis TABLE 2 1 Connection Methods Connection Rack Server Supported Method Mounted Module Interface Comments Description Ethernet Yes Yes CLI and This is the normal method of connecting to the WebGUI ILOM You must know the ILOM s Ethernet address Note This is the only method that supports WebGUI access Serial direct Yes No CLI only Connect directly to serial management port on server Serial through No Yes CLI only Connect a dongle cable directly to the server dongle cable module Serial through No Yes CLI only Log in to the CMM navigate to server module chassis CMM then execute command to start ILOM 2 11 The following sections describe each method Connecting to the ILOM Using an Ethernet Connection The Ethernet connectivity provides full access to the ILOM CLI and WebGUI m For rack mounted servers you must connect a LAN to the Ethernet port and configure your Ethernet connection m For server modules in a chassis you must connect a LAN to the NET MGT port on the chassis When a server module is installed in a chassis the ILOM is automatically connected to the same subnet as the CMM ILOM Note Some server modules have different non ILOM service processors See the documentation provided with the server module for more details To connect to the Ethernet you must know the ILOM s IP addre
111. ntegrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 12 3 2 1 12 3 2 2 Configuring the ILOM Using the CLI 1 Enter the proxy user name and password From the command line type set SP clients ldap binddn cn proxyuser ou sales dc sun dc com bindpw password Enter the IP address of the LDAP server From the command line type set SP clients ldap ipaddress ldapipaddress Assign the port used to communicate with the LDAP server the default port is 389 From the command line type set SP clients ldap port ldapport Enter the distinguished name of the branch of your LDAP tree that contains users and groups From the command line type set SP clients ldap searchbase ou people ou sales dc sun dc com This is the location in your LDAP tree that you want to search for user authentication Set the state of the LDAP service to enabled From the command line type set SP clients ldap state enabled To verify that LDAP authentication works log in to the ILOM using an LDAP user name and password Note The ILOM searches local users before it searches LDAP users If an LDAP user name exists as a local user the ILOM uses the local account for authentication Configuring the ILOM Using the WebGUI 1 2 Log in to the ILOM as administrator or operator Select User Management gt LDAP Settings The LDAP Settings page appears Chapter 12 Lightweight Directory Access Pro
112. o aH Properties type Disk Backplane Commands cd show Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 The following display shows a device HDI DO and a temperature sensor T_AMB gt show SYS HD HDDO SYS HD HDDO Targets STATE FAI OK2RM L Properties type Hard Disk FRU product_name none gt show SYS HD T_AMB SYS HD T_AMB Targets Properties type Temperature class Threshold Sensor value 25 000 degree C upper_nonrecov_threshold upper_critical_threshold lower_nonrecov_threshold lower_critical_threshold Commands cd show product_manufacturer HITACHI product_version V440A94A product_part_number HDS7225SBSUN250G product_serial_number VDK41DT4EG9GNK Commands cd show 43 00 degree C 38 00 degree C upper_noncritical_threshold 33 00 degree C 0 00 degree C 0 00 degree C lower_noncritical_threshold 0 00 degree C Chapter 8 Managing the Host Using the CLI 8 4 Setting the Locate LED The locate LED is a white LED that you can light to help you find your server in a crowded equipment room It has two states fast blink and Off m To turn off the LED type set SYS LOCATE value Off m To turn on the LED type set SYS LOCATE value Fast_Blink 8 9 Managing ILOM Alerts The system is equipped with a number of sensors that measure voltages temperatures and other things ILOM polls
113. ode The ILOM stops its normal operation and prepares for a flash upgrade 7 Type the path to the new ILOM flash image file in the Select Image File to Upload field or click Browse to locate and select the firmware update file ima Chapter 7 Managing the ILOM Using the WebGUI 7 11 FIGURE 7 6 Image File Page Role User Administrator root SP Hostname Sun Integrated Lights Out Manager Firmware Upgrade The Service Processor is now in Upgrade mode Please specify the filename of the Firmware Image that you want to load Clicking on the Browse button will allow you to select the firmware image file Once you do that click on the Upload button to upload the image file to the Service Processor Select image file to upload Browse Cancel 8 Click Upload The Upgrade wizard copies the selected file into the ILOM s DRAM and then verifies that the copy procedure was successful This takes about one minute with a fast network connection The system displays a confirmation dialog box Note A network failure during the file upload will result in a time out and the ILOM will reboot with the prior version of the ILOM firmware 9 Click OK The Verify Firmware Image page appears FIGURE 7 7 Verify Firmware Image Page REFRESH LOG OUT Sun Integrated Lights Out Manager Firmware Upgrade The Service Processor is now in Upgrade mode Please specify
114. og in to the CLI a Type the default user name root b Type the default password changeme Once you have successfully logged in the CMM ILOM displays its default command prompt gt You are now connected to the CMM ILOM CLI 6 Navigate to the server module ILOM by typing this command cd CH BLN SP c1li Where n is number of the server module 7 Enter the command start A prompt appears 8 Enter y to continue or n to cancel If you entered y the server module ILOM prompts for its password Note The CMM ILOM logs on to the server module ILOM using the user name in the user target under CH BLn SP cli where n is the server module number See the chassis documentation for additional details 9 Enter the password when prompted The default is changeme The server module ILOM prompt appears 10 When you are done type exit The server module ILOM exits and the CMM CLI prompt appears 2 6 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 The following display shows an example of the login screen gt cd CH BL2 SP c1li CH BL2 SP cli gt start Are you sure you want to start CH BL2 SP cli y n y Password Type the password to the server module ILOM Sun TM Integrated Lights Out Manager Version N N Copyright 2006 Sun Microsystems Inc All rights reserved Use is subject to license terms Warning password is set to factory default gt e
115. on and a managed node in this case the ILOM Network management stations host management applications which monitor and control managed nodes 14 1 Managed nodes are any number of devices including servers routers and hubs that host SNMP management agents responsible for carrying out the requests from management stations The management station monitors nodes by polling management agents for the appropriate information using queries Managed nodes can also provide unsolicited status information to a management station in the form of a trap SNMP is the protocol used to communicate management information between the management stations and agents The SNMP agent is preinstalled and runs on the ILOM so all SNMP management of the server should occur through the ILOM To utilize this feature your operating system must have an SNMP client application See your operating system vendor for more information The SNMP agent on your ILOM provides the following capabilities inventory management and sensor and system state monitoring 14 2 SNMP Management Information Base MIB Files The base component of an SNMP solution is the management information base MIB A MIB is a text file that describes a managed node s available information and where it is stored When a management station requests information from a managed node the agent receives the request and retrieves the appropriate information from the MIBs The Sun server supports t
116. on to manage disparate resources such as printers disk drives or CPUs A terminal or dedicated window on a screen where system messages are displayed The console window enables you to configure monitor maintain and troubleshoot many server software components The international standard for time UTC was formerly called Greenwich Meridian Time GMT UTC is used by Network Time Protocol NTP servers to synchronize systems and devices on a network A file created by the Solaris or Linux operating system when a program malfunctions and terminates The core file holds a snapshot of memory taken at the time the fault occurred Also called a crash dump file A system event that seriously impairs service and requires immediate attention A type of installation in which the Solaris software is automatically installed on a system that is based on a user defined profile A system component that the user can replace without special training or tools A common algorithm for encrypting and decrypting data Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Desktop Management Interface DMI digital signature Digital Signature Algorithm DSA direct memory access DMA directory server disk array disk partition Distinguished Name DN Distributed Management Task Force DMTF domain Glossary 5 A specification that sets standards for accessing technical support informa
117. on to the host Change the host serial port configuration Note This speed setting must match the speed setting for serial port 0 COM1 or dev ttySO on the host operating system Command show SP network set SP network pendingipaddress ipaddress pendingipdiscovery dchp static pendingipgateway ipgateway pendingipnetmask ipnetmask commitpending true show SP serial external set SP serial external pendingspeed integer commitpending true show SP serial host set SP serial host pendingspeed integer commitpending true TABLE A 5 Alert Commands Description Command Display information about PET alerts You can configure up to 15 alerts Change alert configuration show SP alert rules 1 15 set SP alert rules 1 15 destination ipaddress level down critical major minor Appendix A Command Line Interface Reference A 3 TABLE A 6 System Management Access Commands Description Command Display information show SP services http about HTTP settings Change HTTP set SP services http port portnumber secureredirect settings such as enabled disabled enabling automatic servicestate enabled disabled redirection to HTTPS Display information show SP services https about HTTPS access Change HTTPS set SP services https port portnumber servicestate settings enabled disabled Display ssh DSA show SP services ssh keys dsa key settings Display ssh RSA show SP services ssh k
118. one host to log in to a remote host A Telnet user of one host who is logged in to a remote host can interact as a normal terminal user of the remote host Minimum and maximum values within a range that sensors use when monitoring temperature voltage current and fan speed A specified time after which the server should stop trying to finish a service routine that appears to be hung Part of the Transmission Control Protocol Internet Protocol TCP IP that records and maintains information about the state of a connection An Internet protocol that provides for the reliable delivery of data streams from one host to another TCP IP transfers data between different types of networked systems such as systems running Solaris Microsoft Windows or Linux software TCP guarantees delivery of data and that packets will be delivered in the same sequence in which they were sent Event notification made by Simple Network Management Protocol SNMP agents by their own initiative when certain conditions are detected SNMP formally defines seven types of traps and permits subtypes to be defined A simple transport protocol that transfers files to systems TFTP uses User Datagram Protocol UDP An auxiliary or backup power supply that provides electrical service over extended system power outages A UPS for a LAN or computer system provides continuous power in the event of a power failure An external bus standard that supports data transfer rates o
119. onents without radio buttons cannot be modified Choosing the Prepare to Remove action shuts down the selected component and lights its blue Ready to Remove LED Component Management Status Component Name Type Ready to Remove Status Fault Status ISYSIFIOBD 10 Board ISYSISP Management Processor OK SYS SP NETO Network Interface fa 7 iSYSIFTO FMO Front Fan OK ISYSIFTOMFM1 Front Fan OK ISYSIFTOFM2 Front Fan OK ISYSIFT1FMO Front Fan OK ISYSIFT1IFM1 Front Fan OK ISYSIFTAFM2 Front Fan OK iSYS MB Motherboard ml SYS MBINETO Network Interface SYS MBINET1 Network Interface ISYS MBIPO Host Processor OK SYS MBIPO DO DIMM OK ISYSIMB PO D1 DIMM OK ISYSIMB PO D2 DIMM OK ISYSIMB PO D3 DIMM OK ISYSIMBIP1 Host Processor OK ISYSIMB P1 D0 DIMM OK ISYSIMB P1 D1 DIMM OK ISYSIMB P1 D2 DIMM OK 3 Click a component for detailed information about it Detailed information about the selected component appears 9 4 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 FIGURE 9 3 Sample Component Details View Mozilla Sun Integrated Lights Out Manager View component name and information SYS FTO FMO Property Value type Front Fan FRU fault_state ok Close 4 To prepare a hot pluggable component for removal click the corresponding radio button Note Most components are either hot swappable can be removed without preparation or you mus
120. onfiguration To connect to the system console using the ILOM the ILOM must be set to its default settings 9600 baud 8N1 eight data bits no parity one stop bit no flow control 4 Select the baud rate for the external serial port from the External Serial Port drop down menu This setting must match the baud rate on the RJ 45 serial port on the Sun server 5 Click Save for your changes to take effect or click Cancel to return to the previous settings 72 Configuring ILOM Network Settings This section describes how to configure the network parameters for the ILOM Chapter 7 Managing the ILOM Using the WebGUI 7 3 The ILOM automatically configures its IP settings using the Dynamic Host Configuration Protocol DHCP If your network does not support this protocol you need to set the parameters manually 1 Log in to the ILOM as administrator 2 Select Configuration gt Network The Network Settings page appears 7 4 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 FIGURE 7 2 Network Settings Page Sun Integrated Lights Out Manager Role User Administrator root SP Hostname SUNSPO003BA84D771 REFRESH Loc OUT gt Java Sun Microsystems inc inSain Tefen oth nal System Monitoring Configuration User Management Remote Control Maintenance Alert Management System Management Access T Network Serial Port Clock Setting
121. onfigured with the role administrator You cannot delete this user ID or change its role attributes The initial password changeme is also provided This password is required to log in on the serial port secure shell ssh and the WebGUI To increase secure access to the ILOM change the default password to a new unique password See Chapter 5 for details 3 Click Log In The WebGUI appears 4 To log out of the WebGUI click Log Out at the top right of the WebGUI You are logged out and the Login screen appears Note Do not use the Log Out button in your web browser to log out from the WebGUI Chapter 4 Using the WebGUI 4 5 FIGURE 4 3 WebGUI Log Out Screen Su n Integrated Lights Out Manager You nave been logged out SP Hostname SUNSPOO003BA84D771 User Name root Password Aa Csm 4 6 Integrated Lights Out Manager ILOM Administration Guide for I LOM 1 1 1 May 2007 CHAPTER 5 Managing User Accounts This chapter describes how to manage user accounts using the CLI and the WebGUI It includes the following sections m Section 5 1 User Accounts Overview on page 5 1 m Section 5 2 Managing User Accounts Using the CLI on page 5 2 m Section 5 3 Managing User Accounts Using the WebGUI on page 5 4 5 1 User Accounts Overview The ILOM supports up to nine user accounts The root account is set by default and cannot be removed Therefore
122. onnect a dongle cable directly to the server module and connect a the terminal to the DB9 connector on the dongle cable using a DB9 to RJ 45 serial adapter Refer to your platform specific documentation for additional details Press Enter on the terminal device This establishes the connection between the terminal device and the ILOM Note If you connect a terminal or emulator to the serial port before it has been powered on or during its power on sequence you will see bootup messages When the server has booted the ILOM displays its login prompt SUNSPunnnnnnnnn login The first string in the prompt is the default host name It consists of the prefix SUNSP and the ILOM s media access control MAC address The MAC address for each ILOM is unique Log in to the CLI a Type the default user name root b Type the default password changeme When you have successfully logged in the ILOM displays the ILOM default command prompt gt The ILOM is accessing the CLI You can now run CLI commands For example to display status information about the motherboard in your server type the following command gt show SYS PROC Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 ALG 7 When you are done type exit to quit Chapter 3 describes how to use the CLI Connecting to the ILOM through the CMM The chassis serial connector connects to the CMM ILOM which provid
123. ontinued Port Interface Application 7578 TCP Video Data 161 UDP SNMP V3 Access 3072 UDP Trap Out outgoing only Note If the ILOM is configured to use HTTP it uses TCP port 80 10 1 2 CD and Diskette Redirection Operational Model When you redirect the local client CD drive or diskette drive to a remote host server the following rules apply a In all cases the CD drive and diskette drive appear to be plugged in to the host a If you don t redirect them the host will act as if there is no medium unless there is a CD in the host CD drive If there is a CD in the host CD drive the host accesses it normally Chapter 10 Using The Remote Console Application 10 3 Information in TABLE 10 3 describes different case scenarios in which the remote console application and CD drive and diskette drive redirection operate TABLE 10 3 Remote Console Operation With DVD Drive and Diskette Drive Case Status DVD As Seen by Host Diskette As Seen by Host 1 Remote console application not DVD device present No medium Diskette device present No started or Remote Console indication is sent to the host from medium indication is sent to the started but DVD diskette the ILOM whenever the hosts host from the ILOM whenever redirection not started asks the host asks 2 Remote console application DVD device present Whenever Diskette device present started with no medium present the host asks which may be Whenever the host asks for
124. operties destination_ipl destination_ip2 Commands cd set show gt set destination_ipl none none nn nn nn nn Chapter 8 Managing the Host Using the CLI 8 11 8 12 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 9 Managing the Host Using the WebGUI This chapter describes how to view the state of the host and how to manage it using the WebGUI It contains the following sections m Section 9 1 Controlling Power to the Host Server on page 9 1 m Section 9 2 Viewing Replaceable Component Information on page 9 2 m Section 9 3 Viewing Sensors on page 9 5 m Section 9 4 Viewing Indicator LEDs and Controlling the Locate LED on page 9 8 m Section 9 5 Managing Alerts on page 9 10 m Section 9 6 Viewing and Clearing the System Event Log on page 9 13 m Section 9 7 Viewing ILOM Hardware Firmware and IPMI Versions on page 9 17 9 1 Controlling Power to the Host Server 1 Log in to the WebGUI as described in Section 4 2 Logging In to the WebGUI on page 4 4 2 Select Remote Control gt Remote Power Control The Server Power Control page appears 9 1 FIGURE 9 1 Server Power Control Page REFRESH Loo our Role User Administrator root SP Hostname SUNSPO003BA84D771 Sun Integrated Lights Out Manager Redirection Remote Power Control Mouse Mode Settings l
125. oth HTTP and HTTPS are disabled you lose access to the ILOM web interface To regain access you must log into the CLI and enable HTTP or HTTPS access HTTP Webserver Redirect HTTP Connection to HTTPS Mi HTTP Port 80 HTTPS Webserver vV Enabled HTTPS Port 443 3 Select the HTTP or HTTPS web server a To enable HTTP Select Enabled from the drop down list You can also select a Redirect HTTP Connection to HTTPS HTTP connections are automatically redirected to HTTPS a Disabled Turn HTTP off m To enable HTTPS Select the HTTPS Web Server Enabled check box The HTTPS web server is enabled by default Note If you disable HTTP or select Redirect HTTP Connection to HTTPs and then disable HTTPS you will be unable to access the WebGUI To restore access use the CLI SP services http or https commands as described in Section 6 7 Enabling HTTP or HTTPS Web Access on page 6 8 4 Assign an HTTP or HTTPS port number 5 Click Save to save your settings 7 14 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 7 8 Uploading a New SSL Certificate This section describes how to upload a Secure Sockets Layer SSL certificate and SSL private key to use when accessing the ILOM To establish a secure HTTPS connection to the ILOM you must upload an SSL certificate and a private key into the ILOM These two together help provide a secure connection
126. ount Type the following command to delete a local user account delete SP users username Displaying User Accounts Type the following command to display information about all local user accounts show SP users 5 2 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 5 2 4 5 2 4 1 5 2 4 2 Configuring User Accounts Use the set command to change passwords and roles for configured user accounts Syntax set target propertyname value Targets Properties and Values The following targets properties and values are valid for local user accounts TABLE 5 1 Valid Targets Properties and Values for Local User Accounts Target Property Value Default SP users username permissions administrator operator operator password string Examples When changing the role for user1 from administrator to operator type gt set SP users user1l role operator To change the password for user1 type gt set SP users userl password Changing password for user SP users userl1 password Enter new password Enter new password again New password was successfully set for user SP users userl Note You must have administrator privileges to change user properties Chapter 5 Managing User Accounts 5 3 De Managing User Accounts Using the WebGUI This section describes how to add modify and delete user accounts using the WebGUI 5 3 1 Adding User
127. pending true where XXX XXX XX XX YYY YYY YYY y and zzz zzz zz zzz are the IP address netmask and gateway for your ILOM and network configuration To configure a dynamic IP address type set pendingipdiscovery dhcp set commitpending true If you configure the ILOM to use DHCP your installation must meet the conditions described in Section 2 2 2 Using DHCP to Assign an IP Address on page 2 8 Log out of the ILOM Configuring the IP Address Using the WebGUI To configure the ILOM IP address using the WebGUI do the following 1 Connect to the ILOM through a web browser as described in Section 2 1 1 Connecting to the ILOM Using an Ethernet Connection on page 2 2 Log in to the WebGUI The default user name is root and the default password is changeme Choose the Configuration tab and its Network tab to display information about the current ILOM network configuration See FIGURE 2 1 Select and configure the IP address a To use DHCP select the radio button next to Obtain an IP Address Automatically Use DHCP If you select DHCP your installation must meet the conditions described in Section 2 2 2 Using DHCP to Assign an IP Address on page 2 8 b To use a static IP address i Select the radio button next to Use the Following IP Address ii Enter the IP address subnet mask and gateway IP address in the corresponding fields See FIGURE 2 1 Chapter 2 Connecting and Initial Setup 2 11
128. powered chassis This usually happens within one minute However if the management Ethernet is not connected or if the ILOM s Dynamic Host Configuration Protocol DHCP process fails due to the absence of a DHCP server on the management network the ILOM might take a few minutes to boot Disabling the use of the browser proxy server if one is used for access to the management network might make the WebGUI response time faster Note Do not use the Refresh or Log Out buttons in your Internet web browser when using the WebGUI Instead use only the Refresh and Log Out buttons provided at the top right of the WebGUI window You need the IP address of the ILOM For information on viewing and setting the IP address see Section 2 2 Configuring the ILOM IP Address on page 2 7 1 To log in to the WebGUI type the IP address of the ILOM into your web browser The Login screen appears Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 FIGURE 4 2 WebGUI Login Screen Sun Integrated Lights Out Manager SP Hostname SUNSPOOO3BA84D771 User Name ro Password Es z 2 Type your user name and password When you first try to access the WebGUI it prompts you to type the default user name and password The default user name and password are m Default user name root a Default password changeme The default user name and password are in lowercase characters The user root is prec
129. r 2 Select System Monitoring gt Indicators The Indicators display appears 9 8 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 FIGURE 9 6 Sample Indicators Page REFRESH LOG out P Host Integrated Lights Out Manager System Information System Monitoring Configuration User Management e Con Maintenance M Sensor Readings Indicators Event Logs Indicators Manage the system Locator indicators and view the status of other indicators from this page To modify an indicator select the radio button next to that indicator then choose an option from the Action drop down list The Locate indicators are the white LEDs Actions v 3 Name Status ISYSIPSU_FAULT off sSYS TEMP_FAULT off z ISYSIFAN_FAULT off ISYSIPOWER On O SYSILOCATE of ISYSISERVICE off iSYSIPSOMINOK off ISYSIPSO PWROK off iSYSIPS1VINOK off ISYSIPS1 PWROK off SYSISASBP HDDOISERVICE off ISYSISASBPIHDD1 SERVICE off iSYSISASBP HDD2SERVICE oft ISYSISASBP HDD3 SERVICE off SYSIMB PO SERVICE off J ISYSIMB POIDO SERVICE off iSYSIMB POID1 SERVICE off SYSIMB POID2ISERVICE off SYSIMB POID3ISERVICE off ISYSIMBIP1 SERVICE off SYSIMB P1 DOISERVICE of RRHH H mal Note The sensors shown in FIGURE 9 6 are examples only The actual sensor names ranges and functions might be different on your platform For details see your platform supplement 3 Use th
130. r you want to access with this feature which is enabled by default Menable Single Sign On fuses L C Name Role O root Administrator 3 Click Add The Add User dialog box appears Chapter 5 Managing User Accounts 5 5 FIGURE 5 2 Add User Dialog Box Mozilla Sun Integrated Lights Out Manager The user name must be 4 to 16 characters and must start with an alphabetic character and use no spaces The password must be 8 to 16 characters which are case sensitive Use any characters except a colon or space User Name mike Password soos Confirm Password mA Role Operator Save Close 4 Complete the following information a Type a user name in the User Name field The user name must be at least 4 characters and no more than 16 characters User names are case sensitive and must start with an alphabetical character You can use alphabetical characters numerals hyphens and underscores Do not include spaces in user names b Type a password in the Password field The password must be at least 8 characters and no more than 16 characters The password is case sensitive Use alphabetical numeric and special characters for better security You can use any character except a colon Do not include spaces in passwords c Retype the password in the Confirm Password field d Select Administrator or Operator from the Role drop down menu e When you are done entering the ne
131. raps as defined in the Intelligent Platform Management Interface IPMI v2 0 A special criteria informational is reserved for system events that are not related to sensors Each line in the alert management view is called a rule Each rule identifies an alert level and sends all alerts at that level to the specified IP address Note Because there are four alert levels and 15 alert rules you can configure the system to send the same level of alert to multiple destinations Viewing Alert Destinations Users with operator privileges can view the alert settings Changing them requires administrator privileges 9 10 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 1 Log in to the ILOM as administrator or operator 2 Select Configuration gt Alert Management The Alert Settings page displays a list of alerts FIGURE 9 7 Alert Destination Page Configuration Alert Settings System Management Access Alert Management Network Serial Port Clock Settings Syslog Select a radio button then select Edit from the Actions drop down list to configure an alert You can configure up to 15 alerts Only IPMI Platform Event Traps PETs are supported Actions M E Alert 1D Destination IP Level Alert Type O 1 0 0 0 0 disable ipmipet Ol2 0 0 0 0 disable ipmipet O 3 0 0 0 0 disable ipmipet Ol4 0 0 0 0 disable ipmipet Os 0 0 0 0 disable ipmipet
132. rd becomes changeme a The BIOS password is cleared so that when you attempt to access the BIOS it does not prompt for a password This procedure requires changing a hardware jumper in your server enclosure See your service manual for details 6 6 Updating the ILOM Firmware You can use CLI to update the ILOM firmware Updating the ILOM from the command line enables you to update both the ILOM firmware and the BIOS at the same time See Section A 2 6 Using the load Command on page A 10 for more information Caution Ensure that you have reliable power before upgrading your firmware If power to the system fails for example if the wall socket power fails or the system is unplugged during the firmware update procedure the ILOM could be left in an unbootable state Chapter 6 Managing the ILOM Using the CLI 6 7 Caution Shut down your host operating system before proceeding Otherwise the ILOM will shut the host down ungracefully which could cause filesystem corruption Note The upgrade takes about five minutes During this time no other tasks can be performed in the ILOM 1 If the server OS is running perform a clean shutdown 2 Type the following command to update the ILOM firmware load source URL Note A network failure during the file upload results in a time out This causes the ILOM to reboot with the prior version of the ILOM firmware Example gt load source
133. re connection between a web server and a web client Hypertext Transfer Protocol Secure HTTPS uses SSL sensor data record SDR To facilitate dynamic discovery of features the Intelligent Platform Management Interface IPMI includes this set of records They include software information such as how many sensors are present what type they are their events threshold information and so on The sensor data records enable software to interpret and present sensor data without any prior knowledge about the platform Serial Attached SCSI SAS A point to point serial peripheral interface that links controllers directly to disk drives SAS devices include two data ports that enable failover redundancy which guarantees data communication through a separate path serial console A terminal or a tip line connected to the serial port on the service processor A serial console is used to configure the system to perform other administrative tasks server certificate A certificate used with Hypertext Transfer Protocol Secure HTTPS to authenticate web applications The certificate can be self signed or issued by a Certificate Authority CA Server Message Block SMB protocol A network protocol that enables files and printers to be shared across a network The SMB protocol provides a method for client applications to read and write to files on and request services from server programs in the network The SMB protocol enables you to mount file sy
134. rget Property Value Default SP services http securedirect enabled enabled disabled servicestate enabled disabled disabled port lt portnum gt 80 SP services https servicestate enabled enabled disabled port lt portnum gt 443 Chapter 6 Managing the ILOM Using the CLI 6 9 6 8 Viewing ssh Settings Use the show command to view ssh settings These are read only values that you can display but not write TABLE 6 6 shows the valid targets and properties for ssh values TABLE6 6 Valid Targets and Properties for ssh Target Property SP services ssh keys dsa fingerprint length publickey SP services ssh keys rsa fingerprint length publickey 6 10 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 Use the show command to enter dsa or rsa values Example gt show SP services ssh keys dsa SP services ssh keys dsa Targets Properties fingerprint 7 49 85 b0 e3 65 c0 d0 96 48 06 5 8c b7 9c 6b length 1024 publickey AAAAB3NzaC1kc3MAAACBAKh LPnkehPi Iou9 6JraqiZ7qjJ4KTc4DdNJ3ZkBZ94X Krz2B5BNROCL7h4Gb7uAaMZEgtpPqefKy5awEvkA8 jNyL5 P Commands cd show 6 9 Displaying ILOM Information You can display active sessions current versions and other information about the ILOM using the CLI TABLE 6 7 shows the commands and the information they display TABLE 6 7 Commands to Display ILOM Information Command Information Displayed v
135. rs 2 Choose Devices gt Mouse to enable mouse redirection 3 If keyboard redirection is disabled choose Devices gt Keyboard to enable it Note Keyboard redirection is selected by default Chapter 10 Using The Remote Console Application 10 11 FIGURE 10 7 Keyboard and Mouse Selected H Keyboard 7 Mouse 1 CD ROM L Floppy I CD ROM Image J Floppy Image 4 Use the Keyboard menu to control keyboard attributes and to send special characters that might not be available on the keyboard in remote console mode FIGURE 10 8 Keyboard Menu Options J Auto Keybreak Mode J Left Alt Key J Right Alt Key F10 Control Alt Delete m Selecting Auto Keybreak Mode causes the SP to send a key release event automatically Use this mode when network latency causes the host to act as if keys are being held down a To simulate a Ctrl Alt key sequence a b c d Choose Left Alt Key or Right Alt Key Hold down the Ctrl key Release the Ctrl key Deselect Left Alt Key or Right Alt Key m To send F10 used in BIOS click F10 m To send a break click Control Alt Delete 10 12 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 10 3 2 Redirecting Storage Devices This section describes how to enable a storage device attached to your local workstation or laptop to serve as a storage device for a server You can use this option to install software from a loc
136. rs 1 2 address lt IP address gt lt hostname gt none none Appendix A Command Line Interface Reference A 13 TABLE A 13 Targets Properties and Values for the set Command Continued Valid Targets Properties Values Default SP network commitpending true none pendingipaddress lt IP address gt none none pendingdiscovery dhcp static dhcp pendingipgateway lt IP address gt none none pendingipnetmask lt IP dotted decimal gt 255 255 255 255 SP serial external commitpending true none flowcontrol none none pendingspeed lt decimal from list gt 9600 SP serial host commitpending true none pendingspeed lt decimal from list gt 9600 Examples A 2 9 gt set SP users susan role administrator gt set SP clients ldap state enabled binddn proxyuser bindpw ez24get Using the show Command Use the show command to display information about targets and properties Using the display option determines the type of information shown If you specify display targets then all targets in the namespace below the current target are shown If you specify display properties all property names and values for the target are shown With this option you can specify certain property names and only those values are shown If you specify display a11 all targets in the namespace below the current target are shown and the properties of the specified target are shown If you do not specify a display option
137. s show SP network Configuring Network Settings Use the set command to change properties and values for network settings Network settings have two sets of properties pending and active The active settings are the settings currently in use by the ILOM These settings are read only If you want to change settings enter the updated settings as the pending settings pendingipaddress or pendingipgateway then set the commitpending property to true This prevents accidental disconnections for both port and network settings Note Ensure that the same IP address is always assigned to an ILOM by either assigning a static IP address to your ILOM after initial setup or configuring your DHCP server to always assign the same IP address to an ILOM This enables the ILOM to be easily located on the network Syntax set target propertyname value Chapter 6 Managing the ILOM Using the CLI 6 3 6 2 2 2 6 4 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Targets Properties and Values The following targets properties and values are valid for ILOM network settings TABLE 6 2 ILOM Network Targets Properties and Values Target Property Value Default SP network ipaddress These read only ipdiscovery values are updated ipgateway by the system ipnetmask macaddress MAC address of ILOM commitpending true none none pendingipaddress lt ipaddress none gt none pendingipdiscovery d
138. s Syslog Network Settings radio button next to the appropriate mode then enter settings as needed MAC Address 00 03 BA 84 D7 71 Obtain an IP Address Automatically use DHCP Use the Following IP Address O IP Address 10 6 153 148 Subnet Mask 255 255 252 0 Gateway 10 6 152 1 View the MAC address and configure network settings for the Service Processor from this page DHCP is the default mode but you can manually configure the Netmask Gateway and IP address Select the 3 Complete the information in the Network Settings page Use the descriptions in TABLE 7 1 when completing the information TABLE 7 1 Network Settings Page Fields Item MAC Address Configuration Method IP Address Subnet Mask Default Gateway Description The ILOM s MAC address is set at the factory The MAC address is a hardware address that is unique to each networked device The ILOM s MAC address is provided on a label on the ILOM on the Customer Information Sheet included on the ship kit and in the BIOS Setup screen Select one of the following radio buttons to configure the ILOM s IP address either dynamically or statically e Obtain an IP Address Automatically Use DHCP Enables a DHCP server to configure the ILOM s IP address dynamically e Use the Following IP Address Enables you to configure the ILOM s IP address with a static IP The IP Address Subnet Mask and Default Gateway fields will be
139. s a device such as an intelligent Ethernet controller to autonomously scan ASF compliant sensors on the motherboard for voltage temperature or other excursions and to send Remote Management and Control Protocol RMCP alerts according to the Platform Event Trap PET specification ASF was intended primarily for out of band management functions for client desktops ASF is defined by the Distributed Management Task Force DMTF authentication The process that verifies the identity of a user in a communication session or a device or other entity in a computer system before that user device or other entity can access system resources Session authentication can work in two directions A server authenticates a client to make access control decisions The client can authenticate the server as well With Secure Sockets Layer SSL the client always authenticates the server authorization The process of granting specific access privileges to a user Authorization is based on authentication and access control AutoYaST An installation program for SUSE Linux that automates the process of configuring one or more servers Glossary 2 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 B bandwidth baseboard management controller BMC baud rate bind BIOS Basic Input Output System bits per second bps boot loader cache certificate Glossary 3 A measure of the volume of information
140. s not due to any problem If this happens repeat the procedure starting at Step 1 Note You cannot perform any other operation within your current web browser session 12 Close your web browser and reconnect to the ILOM Note If the configuration is not preserved enter BIOS setup and save the optimal default settings re Enabling HTTP or HTTPS Web Access This section describes how to view and modify web server settings ILOM provides the option to control access to the web interface There are four choices a HTTP only a HTTPS only a HTTP and HTTPS a HTTPS and HTTP automatically redirected to HTTPS HTTPS is enabled by default 1 Log in to the ILOM as administrator Chapter 7 Managing the ILOM Using the WebGUI 7 13 2 Select Configuration gt System Management Access gt Web Server The Web Server Settings page appears FIGURE 7 8 Web Server Settings Page REFRESH LOG OUT sdministrator root SP Hostname SUNSPOO03BA84D771 Sun Integrated Lights Out Manager Java a System Information _ System Monitoring Configuration User Management Remote Control Maintenance System Management Access Alert Management Network Serial Port Clock Settings Syslog _ Web Server SNMP SSL Certificate Web Server Settings Configure which types of web server access to allow and the associated ports HTTPS is the default If b
141. sS amp o SUN microsystems Integrated Lights Out Manager ILOM Administration Guide For ILOM 1 1 1 Sun Microsystems Inc www sun com Part No 820 0280 12 May 2007 Revision 01 Submit comments about this document at http www sun com hwdocs feedback Copyright 2007 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology that is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at ht tp www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the e product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Java AnswerBook2 docs sun com Sun Blade
142. sends an Access Request query to the RADIUS server When the server receives an Access Request message from a client it searches the database for that user s authentication information If the user s information is not found the server sends an Access Reject message and the user is denied access to the requested service If the user s information is found the server responds with an Access Accept message The Access Accept message confirms the user s authentication data and grants the user access to the requested service 13 1 All transactions between the RADIUS client and server are authenticated by the use of a shared secret The client and server must each know the secret because it is never passed over the network You must know the shared secret to configure RADIUS authenticating for ILOM To use RADIUS configuration with ILOM you must configure ILOM as a RADIUS client For more information see Section 13 2 Configuring RADIUS Settings on page 13 2 13 2 13 2 1 Configuring RADIUS Settings If you need to provide ILOM access beyond the 10 local user accounts you can configure ILOM to use RADIUS authentication You must have a properly configured RADIUS server before you can use RADIUS authentication with ILOM Before completing this procedure collect the appropriate information about your RADIUS environment as described in Section 13 1 RADIUS Overview on page 13 1 Configuring RADIUS Using the WebGUI
143. set the administration password and clear the BIOS password m The administration root password becomes changeme m The BIOS password is cleared so that when you attempt to access the BIOS it does not prompt for a password This procedure requires changing a hardware jumper in your server enclosure See your service manual for details Chapter 7 Managing the ILOM Using the WebGUI 7 9 7 6 7 10 Upgrading the ILOM Firmware Both the ILOM and BIOS firmware are tightly coupled and are always updated together A single firmware image contains both the ILOM and BIOS firmware Occasionally you might need to downgrade your firmware Downgrading is done exactly the same as upgrading only you choose an older downgraded image in Step 7 Caution Ensure that you have reliable power before upgrading your firmware If power to the system fails for example if the wall socket power fails or the system is unplugged during the firmware update procedure the ILOM could be left in an unbootable state Do not proceed until you have reliable power Caution Shut down your host operating system before proceeding Otherwise the ILOM will shut the host down ungracefully which could cause file system corruption Note The upgrade takes about five minutes to complete During this time no other tasks can be performed in the ILOM To observe the status of the upgrade while it s happening set the session timeout to
144. shipped with your server m The system BIOS setup screen Choose Advanced IPMI 2 0 Configuration Set LAN Configuration MAC address Using the MAC Address to Find the IP Address Once the ILOM has been assigned an IP address by DHCP you can use the MAC address to identify that IP address by looking in the DHCP log file Typically DHCP log file entries are individual lines with the following comma separated fields ID Date Time Description IP Address Host Name MAC Address Locate the MAC address of your ILOM in the MAC Address seventh field of the correct DHCP file entry and record the corresponding value of the IP address fifth field This is the IP address that you must use to access the WebGUI and the remote console Configuring the IP Address Using the BIOS Setup Utility The BIOS Setup Utility allows you to set the ILOM IP address It allows you to configure it manually or use DHCP 1 Unpack your server and connect it to a power source Refer to your platform documentation for details 2 If you are going to use DHCP verify that your DHCP server is configured to accept new MAC addresses 3 Start the BIOS Setup Utility a Boot the system b Watch the boot messages You will see a line that says you can press F2 to enter BIOS setup c After you see the message press F2 After some messages and screen changes the BIOS Setup Utility appears Chapter 2 Connecting and Initial Setup 2 9 Select
145. sion command to display ILOM version information Syntax version Options h help Example gt version version SP firmware version 1 0 0 SP firmware build number 4415 SP firmware date Mon Mar 28 10 39 46 EST 2005 SP filesystem version 0 1 9 A 20 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 APPENDIX B ILOM Ports This appendix lists the ports in the ILOM When configuring firewall access to the ILOM you must allow access to all relevant ports TABLE B 1 ILOM Ports Ports Protocols Applications 80 HTTP over TCP SP ILOM user configurable port 443 HTTPS over TCP SP ILOM user configurable port 5120 TCP SP ILOM remote console CD 5123 TCP SP ILOM remote console diskette 5121 TCP SP ILOM remote console keyboard and mouse 7578 TCP SP ILOM remote console video 22 ssh over TCP ssh secure shell 69 TFTP over UDP TFTP trivial file transfer protocol 123 NTP over UDP NTP network time protocol 161 SNMP over UDP SNMP simple network management protocol 162 IPMI over UDP IPMI platform event trap PET outgoing port 389 LDAP over LDAP lightweight directory access protocol user UDP TCP configurable port 514 Syslog over UDP Syslog outgoing port 546 DHCP over UDP DHCP dynamic host configuration protocol client 623 IPMI over UDP IPMI intelligent platform management interface 1812 RADIUS over UDP RADIUS remote authenticat
146. sponding component s disable N A Don t send alerts at this level Examples To configure an alert type gt set SP alert rules 1 destination 128 145 77 21 level critical To change an alert level to critical type gt set SP alert rules 1 level critical To turn off an alert type gt set SP alert rules 1 level disable Sending Test Alerts The CLI allows you to send test alerts It sends one alert for every rule that is configured 1 Navigate to SP alert rules 2 Type the command set testalert true This sends a test alert for every rule that is not disabled 8 8 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 8 6 Viewing and Clearing Event Logs This section describes how to view and clear the system event log SEL Caution The system event log accumulates various events including administration changes to the ILOM software events and warnings and alerts It also accumulates events from the IPMI log The ILOM tags all events or actions with LocalTime GMT or UDT Browser clients show these events in LocalTime This can cause apparent discrepancies in the event log When an event occurs on the ILOM the event log shows it in UDT but a client would show it local time 1 Navigate to SP logs event 2 From the CLI type show list The event log scrolls onto your screen gt cd SP logs event SP logs event gt show list SP logs even
147. ss To discover and or to configure the ILOM IP address see Section 2 2 1 Viewing the ILOM IP Address on page 2 7 for more information Note The ILOM supports a maximum of 10 active sessions including serial ssh and WebGUI sessions You can view active sessions by entering the command show SP sessions from the CLI Connecting to the CLI 1 Start your ssh client 2 To log in to the ILOM type ssh username ipaddress where username is the user ID and ipaddress is the IP address of the ILOM The default user is root 3 Type your password when prompted The default is changeme The CLI command prompt appears 2 2 Integrated Lights Out Manager ILOM Administration Guide for I LOM 1 1 1 May 2007 2A Connecting to the WebGUI For more detailed instructions see Section 4 2 Logging In to the WebGUI on page 4 4 1 To log in to the WebGUI type the IP address of the ILOM into your web browser The login screen appears 2 Type your user name and password When you first try to access the WebGUI it prompts you to type the default user name and password The default user name and password are m Default user name root a Default password changeme The default user name and password are in lowercase characters 3 Click Log In The WebGUI appears 4 To log out of the WebGUI click Log Out at the top right of the WebGUI The logout screen appears Caution Do not use the Log Ou
148. ssions Display information about commands and targets Display information about a specific command Update the ILOM and BIOS firmware Display a list of the ILOM event logs Command help targets exit version show SP clock show SP cli commands show SP sessions help help create load source tftp newSPimage show SP logs event list TABLE A 3 User Commands Description Add a local user Delete a local user Change a local user s properties Display information about all local users Display information about LDAP settings Change LDAP settings Command create SP users userl password password role administrator operator delete SP users userl set SP users userl role operator show display targets properties all level value all SP users show SP clients ldap set SP clients ldap binddn proxyuser bindpw proxyuserpassword defaultrole administrator operator ipaddress ipaddress A 2 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 TABLE A 4 Network and Serial Port Setting Commands Description Display network configuration information Change network properties for the ILOM Changing certain network properties like the IP address will disconnect your active session Display information about the external serial port Change the external serial port configuration Display information about the serial connecti
149. ssword again in the Confirm Password field Select read only ro or read write rw permissions Select DES or none for a privacy protocol Type a privacy password The privacy password must contain 8 to 16 characters with no colons or space characters It is case sensitive Type the privacy password again in the Confirm Password field 4 Click Save 14 10 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 14 7 3 14 7 4 Deleting an SNMP user 1 Click the Users link or scroll down to the SNMP Users list 2 Select the radio button of the SNMP user to be deleted 3 Click Delete under the SNMP Users list A confirmation dialog box appears 4 Click OK to delete the SNMP user Adding and Editing SNMP Communities 1 Click the Communities link or scroll down to the Communities list 2 Click the Add button or the Edit under the SNMP Communities list The Add or Edit dialog box appears See FIGURE 14 5 FIGURE 14 5 Add Community Dialog Box Add Sun Integrated Lights Out Manager Add Community Name Permission Save 3 Type the community name in the Community Name field The name can contain up to 35 characters It must start with an alphabetic character and cannot contain a space 4 Select read only ro or read write rw permissions 5 Click Save Chapter 14 Using Simple Network Management Protocol SNMP 14 11 14 7 5 14 12 1
150. stem Event Log Page REFRESH LOG OUT Sensor Readings Indicators Event Logs Event Log Displays every event in the system including IPMI Audit and FMA events Click the Clear Log button to delete all current log entries Event Log ill Display a Event ID Class Type Severity Date Time Description 357 Audit Log minor Thu Mar 23 root Open Session object sessiontype value www success 20 47 21 1972 356 Audit Log minor Tue Mar 21 root Close Session session ID 1572826719 success 03 07 48 1972 355 Audit Log minor Tue Mar 21 root Close Session session ID 2063560745 success 03 07 48 1972 354 Audit Log minor Tue Mar 21 root Clase Session session ID 3607090247 success 03 07 47 1972 353 Audit Log minor Tue Mar 21 root Set Session Privilege Level privilege level admin success 03 07 40 1972 352 Audit Log minor Tue Mar 21 root Activate Session authentication type MD5 privilege level admin initial outbound sequence number 0x4B8D0198 challenge string 0x4E 0x77 03 07 40 1972 OxFA OxCB Ox6C 0x5 OxAC 0x86 0x21 Ox2B OxAA 0x1 A 0x55 OxA2 OXBE 0x70 success 351 Audit Log minor Tue Mar 21 root Set Session Privilege Level privilege level admin success 03 07 40 1972 350 Audit Log minor Tue Mar 21 root Set Session Privilege Level privilege level admin success 03 07 40 1972 349 Audit Log minor Tue Mar 21 root Ac
151. stems between Windows and UNIX systems The SMB protocol was designed by IBM and subsequently modified by Microsoft Corp Microsoft renamed the protocol the Common Internet File System CIFS service processor SP A device used to manage chassis environmental configuration and service functions and receive event data from other parts of the system It receives data through sensor interfaces and interprets this data by using the sensor data record SDR to which it provides an interface The SP provides another Glossary 18 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 session time out Simple Mail Transfer Protocol SMTP Simple Network Management Protocol SNMP Small Computer System Interface SCSI Spanning Tree Protocol STP subnet subnet mask superuser system event log SEL Glossary 19 interface to the system event log SEL Typical functions of the SP are to measure processor temperature power supply values and cooling fan status The SP can take autonomous action to preserve system integrity A specified duration after which a server can invalidate a user session A Transmission Control Protocol Internet Protocol TCP IP used for sending and receiving email A simple protocol used to exchange data about network activity With SNMP data travels between a managed device and a network management station NMS A managed device can be any device that runs SNMP s
152. t button in your web browser to log out from the WebGUI Connecting to the ILOM Using a Serial Connection You can access the ILOM CLI at any time by connecting a terminal or a PC running terminal emulation m For rack mounted systems connect the cable directly to the RJ 45 or DB9 serial port m For many server modules in a chassis you have to connect a dongle cable directly to the server module and connect a the terminal to the DB9 connector on the dongle cable You might also require a DB9 to RJ 45 serial adapter For other server modules you can connect directly to the serial port on the server module See the server module documentation for additional details 1 Verify that your terminal laptop or terminal server is operational Chapter 2 Connecting and Initial Setup 2 3 2 4 Configure the terminal device or the terminal emulation software to use the following settings 8N1 eight data bits no parity one stop bit 9600 baud default can be set to any standard rate up to 57600 Disable software flow control CON XOFF Unpack your server and connect the system power cable to a power source Refer to your platform specific documentation for instructions on installing the hardware cabling and powering on Connect a serial cable to the server or server module For rack mounted servers connect a serial cable from the serial port on the server s back panel to a terminal device For server modules c
153. t list Targets Properties Commands show ID Date Time Class Type Severity 1522 Sun Jul 30 01 11 36 2006 Audit Log minor root Close Session object session type value www success 1521 Sun Jul 30 01 05 34 2006 Audit Log minor root Close Session session ID 1307912184 success 3 To scroll down press any key except q 4 To stop displaying the log press q 5 To clear the event log type set clear true The CLI asks you to confirm Chapter 8 Managing the Host Using the CLI 8 9 6 Type y The CLI clears the event log For example gt set clear true Are you sure you want to clear SP logs event y n y Set clear to true Note The SEL accumulates many types of events including copies of entries that IPMI posts to the IPMI log Clearing the SEL clears all entries including the copies of the IPMI log entries However clearing the SEL does NOT clear the actual IPMI log You must use IPMI commands to view and clear the IPMI log 8 7 Sending Logs to Other Machines You can send logs to other machines After an address is configured new messages are sent to the destination machine s in syslog format 1 Navigate to SP clients syslog 8 10 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 2 Enter the IP address of the receiving machine gt cd syslog SP clients syslog gt show SP clients syslog Targets Pr
154. t shut down the system to remove them For these components there is no radio button The system prepares the component for removal then displays its status in the Ready to Remove Status column For a detailed list of components see your platform supplement 9 3 Viewing Sensors This section describes how to view the temperature voltage and fan sensor readings The system is equipped with a number of sensors that measure voltages temperatures and other settings ILOM polls the sensors and posts an event in the sensor event log SEL when they cross a threshold For details on individual sensors see your platform supplement Chapter 9 Managing the Host Using the WebGUI 9 5 9 6 If an event crosses a threshold defined in the Alert Destinations view it generates an alert which is sent to the destination configured in Section 9 5 Managing Alerts on page 9 10 The thresholds appear in the Sensor Readings view shown in FIGURE 9 4 Caution The ILOM tags all events or actions with LocalTime GMT or UDT Browser clients show these events in LocalTime This can cause apparent discrepancies in the event log When an event occurs on the ILOM the event log shows it in UDT but a client would show it as local time 1 Log in to the ILOM as administrator or operator 2 Select System Monitoring gt Sensor Readings The Sensor Readings page appears Note The sensor displays in this section are
155. t to bind to the designated port number A number that specifies an individual Transmission Control Protocol Internet Protocol TCP IP application on a host machine providing a destination for transmitted data The process of turning the power to a system off then on again A program that takes uninitialized system hardware and probes and tests its components at system startup POST configures useful components into a coherent initialized system and hands it over to the OpenBoot PROM POST passes to OpenBoot PROM a list of only those components that have been successfully tested An embedded processor An industry standard client server interface that enables a server to boot an operating system OS over a Transmission Control Protocol Internet Protocol TCP IP network using Dynamic Host Configuration Protocol DHCP The PXE specification describes how the network adapter card and BIOS work together to provide basic networking capabilities for the primary bootstrap program enabling it to perform a secondary bootstrap over the network such Privacy Enhanced Mail PEM programmable read only memory PROM protocol proxy public key encryption R rack unit U random access memory RAM read only file read only memory ROM real time clock RTC reboot Glossary 16 as a TFTP load of an OS image Thus the primary bootstrap program if coded to PXE standards does not need knowledge of the system s net
156. t to server and responses from server to client HTTP is based on Transmission Control Protocol Internet Protocol TCP IP An extension of HTTP that uses Secure Sockets Layer SSL to enable secure transmissions over a Transmission Control Protocol Internet Protocol TCP IP network I in band system management Server management capability that is enabled only when the operating system is initialized and the server is functioning properly install server A server that provides the Solaris software DVD or CD images from which other systems on a network can install the Solaris software Integrated Lights Out Manager ILOM An integrated hardware firmware and software solution for in chassis or in blade system management Intelligent Platform Management Interface IPMI A hardware level interface specification that was designed primarily for out of band management of server systems over a number of different physical interconnects The IPMI specification describes extensive abstractions regarding sensors This enables a management application running on the operating system OS or in a remote system to comprehend the environmental makeup of the system and to register with the system s IPMI subsystem to receive events IPMI is compatible with management software from heterogeneous vendors IPMI functionality includes Field Replacable Unit FRU inventory reporting system monitoring logging system recovery including local and remot
157. take effect or click Close to return to the previous settings The User Accounts page is redisplayed Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 5 3 3 Deleting User Accounts This section describes how to delete a user account 1 Log in to the ILOM as administrator 2 Select User Management gt User Accounts The User Accounts page appears FIGURE 5 5 User Accounts Page Ro REFRESH LOG OUT User Accounts Active Sessions LDAP Settings Radius User Settings Add delete or modify local ILOM user accounts from this page ILOM offers 10 local user accounts The system uses root which you cannot delete The other 9 are available for your use Single Sign On enables an ILOM administrator logged in to the Chassis Monitoring Module to access any blade Service Processor without the need to log in again Single Sign On must be enabled on each Service Processor you wantto access with this feature which is enabled by default V Enable Single Sign On D El Name Role O root Administrator O mike Operator 3 Select the radio button next to the user account you want to delete You cannot delete the root account 4 Click Delete The user accounts page appears with the user deleted Chapter 5 Managing User Accounts 5 10 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER
158. tely Monitor BIOS power on self test POST progress log entries remotely m View IPMI log entries which the operating system can write a Examine component information including CPU information dynamic random access memory DRAM configuration host Media Access Control MAC addresses system serial numbers and other features a Manage user accounts remotely a Power on power off power cycle and reset the system remotely a Administer user accounts 4 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 4 1 4 WebGUI Features FIGURE 4 1 shows a WebGUI page FIGURE 4 1 WebGUI Sample Page Role User Administrator root REFRESH LOG OUT SP Hostname SUNSPOOO3BA84D771 Masthead Sun Integrated Lights Out Manager System Monitoring Configuration User Management Remote Control i Maintenance System Information Versions Session Tim e Out Components Versions Navigation Bar View the version of ILOM firmware currently in use Version Information Property Value SP Firmware Version SP Firmware Build Number SP Firmware Date SP Filesystem Version 1414 Content 13006 Wed Aug 30 17 09 08 PDT 2006 0 1 14 Each WebGUI page has three main sections the masthead the navigation bar and the content area The masthead provides the following buttons and fields on all pages of th
159. the show command acts as if display all was specified The level option controls the depth of the show command and it applies to all modes of the display option Specifying level 1 displays the level of the namespace where the object exists Values greater than 1 return information for the target s current level in the namespace and the lt specified value gt levels below If the argument is level all it applies to the current level in the namespace and everything below A 14 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Syntax show options display targets properties all level value al1 target propertyname Options d display e examine 1 1level Targets and Properties TABLE A 14 Targets for the show Command Valid Targets Properties SYS SP SP alert SP alert rules alertrulename type level destination SP clients ldap binddn bindpw defaultrole ipaddress port searchbase state SP clients radius defaultrole ipaddress port secret state SP clients ntp SP clients ntp server SP clients ntp server 1 2 SP clock datetime usentpserver SP logs Appendix A Command Line Interface Reference A 15 TABLE A 14 Targets for the show Command Continued Valid Targets Properties SP logs event SP logs event list SP network SP serial SP serial external SP serial host SP services SP services http SP services https
160. ties binddn cn Manager dc sun dc com bindpw secret defaultrole Operator ipaddress 129 144 97 180 port 389 searchbase ou people dc sun dc com state disabled Commands cd show Targets server Properties Commands cd show Using the start Command target Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Options h help state Targets TABLE A 16 Targets for the start Command Valid Targets Description SYS Starts powers on the system SP console Starts an interactive session to the console stream Examples gt start SP console gt start SYS A 2 11 Using the stop Command Use the stop command to shut down the target or to terminate another user s connection to the host console You will be prompted to confirm a stop command Eliminate this prompt by using the script option Syntax stop options script target Options force h help Appendix A Command Line Interface Reference A 19 A 2 12 Targets TABLE A 17 Targets for the stop Command Valid Targets Description SYS Perform an orderly shutdown followed by a power off of the specified hardware Use the force option to skip the orderly shutdown and force an immediate power off SP console Terminate another user s connection to the host console Examples gt stop SP console gt stop force SYS Using the version Command Use the ver
161. tificate The SSL Certificate Upload Status dialog appears Chapter 7 Managing the ILOM Using the WebGUI 7 15 5 Once you have uploaded the certificate and private key click OK to reset the ILOM immediately or click Cancel to reset the ILOM later The ILOM must be reset for the new certificate to take effect If you click OK you must close your web browser and reconnect to the ILOM HTTPS is enabled by default You can now access the ILOM securely using the following format in your IP Address field from your web browser https lt ILOM IP address gt For example if the ILOM s IP address is 192 168 0 30 type the following https 192 168 0 30 Note Ensure that you include the s after http 19 7 16 Setting the ILOM Session Timeout Period This section describes how to set the timeout period for your ILOM session Once you set the timeout period if your session is inactive for that amount of time you will be automatically logged out of the session 1 Log in to the ILOM as administrator or operator 2 Select System Information gt Session Time Out The Session Time out page appears Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 FIGURE 7 10 Session Time Out Page REFRESH LOG out Role User Administrator root SP Hostname SUNSPO003BA84D771 Sun Integrated Lights Out Manager System Information System Monitoring Configuration User M
162. tion about computer hardware and software DMI is hardware and operating system OS independent and can manage workstations servers or other computing systems DMI is defined by the Distributed Management Task Force DMTF A certification of the source of digital data A digital signature is a number derived from a public key cryptographic process If the data is modified after the signature was created the signature becomes invalid For this reason a digital signature can ensure data integrity and detection of data modification A cryptographic algorithm specified by the Digital Signature Standard DSS DSA is a standard algorithm used to create digital signatures The transfer of data directly into memory without supervision of the processor In the Lightweight Directory Access Protocol LDAP a server which stores and provides information about people and resources within an organization from a logically centralized location A storage subsystem containing an arrangement of multiple disk drives designed to provide performance high availability serviceability and other benefits A logical section of a physical hard disk drive reserved for a specific file system and function In the Lightweight Directory Access Protocol LDAP a unique text string that identifies an entry s name and location within the directory A DN can be a fully qualified domain name FQDN that includes the complete path from the root of the tree
163. tion provided with the chassis Using UNIX Commands This document might not contain information about basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices Refer to the following for this information m Software documentation that you received with your system m Solaris Operating System documentation which is at http docs sun com xi Shell Prompts Shell Prompt C shell machine name C shell superuser machine name Bourne shell and Korn shell Bourne shell and Korn shell superuser Typographic Conventions Typeface Meaning Examples AaBbCc123 The names of commands files Edit your Login file and directories onscreen Use 1s a to list all files computer output You have mail oe AaBbCc123 What you type when contrasted su with onscreen computer output Password AaBbCc123 Book titles new words or terms Read Chapter 6 in the User s Guide words to be emphasized These are called class options Replace command line variables E You must be superuser to do this with real names or values To delete a file type rm filename The settings on your browser might differ from these settings xii Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Documentation Support and Training Sun Function URL Documentation http www sun com documentation Support http www s
164. tion Guide for LOM 1 1 1 May 2007 Red Hat Package Manager RPM redirection redundant array of independent disks RAID Remote Management and Control Protocol RMCP remote procedure call RPC remote system reset root root directory router RSA algorithm schema Glossary 17 A collection of tools developed by Red Hat Inc for Red Hat Linux that can automate the install uninstall update verify and query software processes on a computer RPM is now commonly used by multiple Linux vendors The channeling of input or output to a file or device rather than to the standard input or output of a system The result of redirection sends input or output that a system would normally display to the display of another system RAID enables a set of disk drives to appear as a single logical disk drive to an application such as a database or file system Different RAID levels provide different capacity performance high availability and cost characteristics A networking protocol that enables an administrator to respond to an alert remotely by powering the system on or off or forcing a reboot A method of network programming that enables a client system to call functions on a remote server The client starts a procedure at the server and the result is transmitted back to the client A system other than the one on which the user is working A hardware level operation that performs a system power off followed by
165. tions target properties The following sections describe each of these 3 2 Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 3 1 3 1 3 1 3 2 Command Verbs The CLI supports the following command verbs TABLE 3 1 CLI Command Verbs Command Description cd Navigates the object namespace create Sets up an object in the namespace delete Removes an object from the namespace exit Terminates a session to the CLI help Displays Help information about commands and targets load Transfers a file from an indicated source to an indicated target reset Resets the state of the target set Sets target properties to the specified value show Displays information about targets and properties start Starts the target stop Stops the target version Displays the version of ILOM firmware Command Options The CLI supports the options listed in TABLE 3 2 Not all options are supported for all commands See a specific command section for the options that are valid with that command The help option can be used with any command TABLE 3 2 Command Options Option Long Form Short Form Description default Causes the verb to perform only its default functions destination Specifies the destination for data display d Shows the data the user wants to display force Causes an immediate action instead of an orderly shutdown help h Displays Help information level 1 Executes th
166. tivate Session authentication type MD5 privilege level admin initial outbound sequence number OxCB7DCC21 challenge string OxF8 03 07 40 1972 OxA4 0x1B 0x13 0xB5 OxCA Ox4E OxE8 0x98 0x32 0x38 OxED 0x79 Ox4D Ox3D 0x34 success 348 Audit Log minor Tue Mar 21 root Activate Session authentication type MDS privilege level admin initial outbound sequence number Ox 30E09AF challenge string 0x15 0x50 03 07 40 1972 0XBB Ox6F 0x22 0x19 OxBA 0x9B Ox7D OxF5 OxB OxE1 Ox1A 0x1 C Ox7F 0x23 success 347 Audit Log minor Tue Mar 21 root Close Session object sessionitype value www success 02 46 43 1972 3 Use the Display drop down menu to determine how many events to display Selecting a larger number might cause the WebGUI to respond more slowly The WebGUI displays the most recent events first To see later events select a larger number 4 Use the scrollbar to scroll through the list 9 14 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 9 6 1 The fields in the Event Log table are described in TABLE 9 3 TABLE 9 3 Event Log Fields Field Description Event ID The number of the event in sequence from number 1 Class Type e Audit Log Commands that result in a configuration change Description includes user command command parameters and success fail e IPMI Log Any event that is placed in the IPMI SEL is also put in the management log e Chassis Stat
167. to the correct server when using HTTPS Ensure that the uploaded SSL certificate and private key match If they do not match secure access may not work properly 1 Log in to the ILOM as administrator 2 Select Configuration gt System Management Access gt SSL Certificate The SSL Certificate Upload page appears FIGURE 7 9 SSL Certificate Upload Page Role User Administrator P Hostname SUNSP0003BA84D771 Sun Integrated Lights Out Manager REFRESH LOG OUT System Information System Monitoring Configuration User Management Remote Control Maintenance aanas gt z System Management Access Alert Management Network Serial Port Clock Settings Syslog Web Server SNMP SSL Certificate SSL Certificate Upload ILOM provides a default SSL certificate and self signing key for HTTPS access Optionally you can upload a different SSL certificate and matching private key Ensure that you can access the new certificate and key through your network or local file system The certificate and key currently in use appears below Default Certificate Default Private Key Select new SSL Certificate to upload Upload Browse 3 Type the file name of the new SSL certificate or click Browse to search for a new SSL certificate The file name has a pem file extension The ILOM does not support pass phrase encrypted certificates 4 Click Upload to upload the selected SSL cer
168. tocol LDAP 12 5 FIGURE 12 2 LDAP Settings Page Role l Sun Integrated Lights Out Manager Adi REFRESH LOG ouT sti UN System Information System Monitoring Configuration User Management Remote Control User Accounts Active Sessions LDAP Settings Radius LDAP Settings Configure ILOM access for LDAP users on this page Select a default role for all of your LDAP users either Administrator or Operator Enter the IP address of your LDAP server Enter the port used to communicate with your LDAP server the default portis 389 Enter the searchbase or portion of your LDAP tree where ILOM should look for LDAP user accounts ou docs dn writers Enter the distinguished name DN and password for a proxy user ILOM can use to access your LDAP tree State Enabled Role Operator Z IP Address mo 7 Port 289 Searchbase f Bind DN Bind Password 12 6 3 4 5 Enter the following values State Select the Enabled check box to authenticate LDAP users Role The default role of LDAP users Select operator or administrator from the drop down menu IP Address The IP address of the LDAP server Port The port number on the LDAP server Searchbase Type the branch of your LDAP server to search for users Bind DN Type the Distinguished Name DN of a read only proxy user on the LDAP server ILOM must have read only
169. uch as hosts routers web servers or other servers on the network An ANSI standard for controlling peripheral devices by one or more host computers SCSI defines a standard I O bus level interface and a set of high level I O commands A networking protocol based on an intelligent algorithm that allows bridges to map a redundant topology and eliminates packet looping in local area networks LANs A working scheme that divides a single logical network into smaller physical networks to simplify routing The subnet is the portion of an Internet Protocol IP address that identifies a block of host IDs A bit mask used to select bits from an Internet address for subnet addressing The mask is 32 bits long and selects the network portion of the Internet address and one or more bits of the local portion Also called an address mask A special user who has privileges to perform all administrative functions on a UNIX system Also called root A log that provides nonvolatile storage for system events that are logged autonomously by the service processor or directly with event messages sent from the host T Telnet threshold time out transmission control block TCB Transmission Control Protocol Internet Protocol TCP IP trap Trivial File Transport Protocol TFTP U uninterruptible power supply UPS Universal Serial Bus USB Glossary 20 The virtual terminal program that enables the user of
170. ule to access any blade Service Processor without the need to log in again Single Sign On must be enabled on each Service Processor you want to access with this feature which is enabled by default V Enable Single Sign On Save E Name Role root Administrator O mike Operator 3 Select a radio button to select a user account to modify 4 Click Edit The Edit User dialog box appears Chapter 5 Managing User Accounts 5 7 5 8 FIGURE 5 4 Edit User Dialog Box Mozilla Sun Integrated Lights Out Manager The password must be 8 to 16 characters which are case sensitive Use any characters except a colon or space User Name mike CI Change New Password Confirm New Password Role Save Close Modify the password if needed a Select the Change check box if you want to change the user password If you do not want to change the password deselect the check box b Type a new password in the Password field The password must be at least 8 characters and no more than 16 characters The password is case sensitive Use alphabetical numeric and special characters for better security You can use any character except a colon Do not include spaces in passwords c Retype the password in the Confirm Password field to confirm the password Select a role from the Role drop down menu After you have modified the account information click Save for your changes to
171. un com support Training http www sun com training Third Party Web Sites Sun is not responsible for the availability of third party web sites mentioned in this document Sun does not endorse and is not responsible or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content goods or services that are available on or through such sites or resources Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 part number 820 0280 12 Preface xiii xiv Integrated Lights Out Manager ILOM Administration Guide for ILOM 1 1 1 May 2007 CHAPTER 1 ILOM and System Management Overview 1 1 This chapter contains the following sections Section 1 1 Introduction on page 1 1 Section 1 2 About Sun N1 System Manager on page 1 4 Introduction The ILOM is a dedicated system of hardware and supporting software that allows you to manage your Sun server independently of the operating system ILOM inclu
172. unconditionally sets the ILOM time to that indicated by the host s RTC The host s RTC is set by the following operations a When the host s CMOS is cleared as a result of changing the host s RTC battery or inserting the CMOS clear jumper on the motherboard The host s RTC starts at Jan 1 00 01 00 2002 m When the host s operating system sets the host s RTC The BIOS does not consider time zones Solaris and Linux software respect time zones and will set the system clock to UTC Therefore after the OS adjusts the RTC the time set by the BIOS will be UTC Microsoft Windows software does not respect time zones and sets the system clock to local time Therefore after the OS adjusts the RTC the time set by the BIOS will be local time a When the user sets the RTC using the host BIOS Setup screen 6 6 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Continuously through NTP if NTP is enabled on the ILOM NTP jumping is enabled to recover quickly from an erroneous update from the BIOS or user NTP servers provide UTC time Therefore if NTP is enabled on the ILOM the ILOM clock is in UTC Through the CLI WebGUI and IPMI 6 4 Resetting the ILOM To reset the ILOM using the CLI type reset SP 6 5 Resetting the ILOM and BIOS Passwords This procedure causes the ILOM to reset the administration password and to clear the BIOS password a The administration root passwo
173. ure it using any of the following sections m Section 2 2 3 Configuring the IP Address Using the BIOS Setup Utility on page 2 9 m Section 2 2 4 Configuring the ILOM Using the CLI on page 2 10 a Section 2 2 5 Configuring the IP Address Using the WebGUI on page 2 11 If these conditions are present when the ILOM is powered on or reset DHCP automatically assigns it an IP address Note Some DHCP servers allow you to specify the IP address that it will assign to the ILOM In this case the ILOM still must be configured for a dynamic IP address even though DHCP s choice of addresses is static Finding the ILOM s MAC Address The ILOM has a unique MAC address that is different from the server or server module s MAC address You might need this address to configure your DHCP server software MAC addresses are 12 digit hexadecimal strings in the format xx xx xx xX KXXX where x represents a single hexadecimal letter 0 9 A F a f Write down that address for future reference You can obtain the ILOM MAC address in one of the following ways m Start the ILOM CLI and enter the command show SP network The ILOM displays its MAC address 2 8 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 Deo m For rack mounted servers there is a label attached to the GRASP board Open the cover of the server to view this label m Check the Customer Information Sheet
174. uring LDAP as a name service for Linux or the Solaris operating system Chapter 12 Lightweight Directory Access Protocol LDAP 12 3 12 3 1 123 2 Configuring the LDAP Server 1 Ensure that all users authenticating to the CMM ILOM have passwords stored in crypt format or the GNU extension to crypt commonly referred to as MD5 crypt For example userPassword CRYPT ajCa2He4PJhNo or userPassword CRYPT 1 pzKng1 du1BfONWBJh9t3FbUgf46 The ILOM supports LDAP authentication only for passwords stored in these two variations of the crypt format Add object classes posixAccount and shadowAccount and populate the required property values for this schema RFC 2307 TABLE 12 1 LDAP Property Values Required Property Description uid User name for logging in to your ILOM uidNumber Any unique number gidNumber Any unique number userPassword Password homeDirectory Any value this property is ignored by the ILOM loginShell Any value this property is ignored by the ILOM Provide the ILOM access to user accounts on your LDAP server Either enable your LDAP server to accept anonymous binds or create a proxy user on your LDAP server that has read only access to all user accounts that will authenticate through the ILOM See your LDAP server documentation for more details Configuring the ILOM After the LDAP server is configured you must configure the ILOM using either the CLI or the WebGUI 12 4 I
175. vileges 2 Navigate to SP services 3 Enter the command sso state enabled to allow users with administrator privileges to start the remote console operation without a login prompt sso state disabled to require users with administrator privileges to log in again when starting the remote console application 10 2 Starting the Remote Console Application From the WebGUI Use this procedure to start the remote console application from the WebGUI 1 Log in to the ILOM as administrator 2 Select Remote Control gt Redirection The Launch Redirection page appears 3 If a login screen appears enter the user name and password of an account that has administrator privileges See Section 10 1 3 Remote Console Security on page 10 5 for details Chapter 10 Using The Remote Console Application 10 5 FIGURE 10 1 Launch Redirection Page REFRESH Los OUT J0144F26DCE5 Sun Microsystems In System Information System Monitoring Configuration Remote Control Redirection Remote Power Control Mouse Mode Settings Launch Redirection Manage the host remotely by redirecting the system console to your local machine Launch the Sun LOM Remote Console to manage multiple blades from one window and utilize the RKVMS features Select 16 bit high quality color redirection for fast connections or 8 bit lower quality color redirection for slower connections I want to see redirection in
176. w user s information click Add The User Accounts page is redisplayed The new user account and associated information is listed on the User Accounts page 5 6 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 5 002 Modifying User Accounts This section describes how to modify an ILOM user account Modifying a user account can change the user s password and their network and serial privileges Note Normally only accounts with administrator privileges are allowed to add modify or delete user accounts However operators can modify their own password If a new user is given administrator privileges those privileges are also automatically granted to the user for the command line interface CLI and Intelligent Platform Management Interface IPMI to the ILOM 1 Log in to the ILOM as administrator 2 Select User Management gt User Accounts The User Accounts page appears FIGURE 5 3 User Accounts Page REFRESH LOG ouT System Information System Monitoring Configuration User Management Remote Control Maintenance User Accounts Active Sessions LDAP Settings Radius User Settings Add delete or modify local ILOM user accounts from this page ILOM offers 10 local user accounts The system uses root which you cannot delete The other 9 are available for your use Single Sign On enables an LOM administrator logged in ta the Chassis Monitoring Mod
177. wn service processor Also the chassis is equipped with a service processor that supports chassis level functionality such as fans and power supplies and that provides access to the service processors on the server modules This chassis level service processor is called a Chassis Management Module CMM For more information on the CMM see the corresponding documentation provided with the chassis 1 2 About Sun N1 System Manager If you plan to manage your server as one resource in a comprehensive data center management solution Sun N1 System Management provides an alternative to ILOM This software suite provides advanced virtualization features that enable you to monitor maintain and provision multiple Solaris Linux and Microsoft Windows servers in your data center The Sun N1 System Manager is available to download from www sun com software solaris index jsp You can also install it from the Sun N1 System Manager DVD shipped in your system box This software suite is installed on a dedicated server in your data center and allows one or more remote management clients to perform the following tasks on multiple managed servers a Manage multiple servers Configure provision deploy manage monitor patch and update from one to thousands of Sun servers Monitor system information System manufacturer make model serial number management MAC addresses disk information expansion slot information and platform
178. working hardware A standard for Internet electronic mail that encrypts data to ensure privacy and data integrity A memory chip on which data can be programmed only once and which retains the program forever PROMs retain data even when power is off A set of rules that describes how systems or devices on a network exchange information A mechanism whereby one system acts on behalf of another system in responding to protocol requests A cryptographic method that uses a two part key code that is made up of public and private components To encrypt messages the published public keys of the recipients are used To decrypt messages the recipients use their unpublished private keys which are known only to them Knowing the public key does not enable users to deduce the corresponding private key A measure of vertical rack space equal to 1 75 inches 4 45 cm Volatile semiconductor based memory in which any byte of memory can be accessed without touching the preceding bytes A file that a user cannot modify or delete A nonvolatile memory chip on which data has been prerecorded Once written onto a ROM chip data cannot be removed and can only be read A battery backed component that maintains the time and date for a system even when the system is powered off An operating system level operation that performs a system shutdown followed by a system boot Power is a prerequisite Integrated Lights Out Manager ILOM Administra
179. xample set SP services http port 80 The following display shows both methods gt cd SP services http Navigate to namespace SP services http gt set port 80 Set port to 80 Enter the verb target and value gt set SP services http port 80 Combine path and show command Set port to 80 Chapter 3 Using the Command Line Interface 3 5 3 6 Integrated Lights Out Manager ILOM Administration Guide for LOM 1 1 1 May 2007 CHAPTER 4 Using the WebGUI This chapter describes how to use the ILOM WebGUI The sections include m Section 4 1 Overview of WebGUI Requirements Users Tasks and Features on page 4 1 m Section 4 1 4 WebGUI Features on page 4 3 m Section 4 2 Logging In to the WebGUI on page 4 4 4 1 Overview of WebGUI Requirements Users Tasks and Features The graphical user interface GUI enables you to monitor and manage local and remote systems Using a standard web browser you can expect to be up and running the WebGUI in less than five minutes One of the most powerful features of ILOM is the ability to redirect the server s graphical console to a remote workstation or laptop system When you redirect the host console you can configure the remote system s keyboard and mouse to act as the server s mouse and keyboard You can also configure the diskette drive or CD ROM drive on the remote system as a device virtually connected to the Sun server You
180. xit Type this command to exit the server module ILOM and return to the CMM ILOM Connection to 10 6 122 33 closed 2 2 2201 Configuring the ILOM IP Address You can configure the ILOM IP address using one of several methods m Using the BIOS Setup Utility See Section 2 2 3 Configuring the IP Address Using the BIOS Setup Utility on page 2 9 m Using the CLI See Section 2 2 4 Configuring the ILOM Using the CLI on page 2 10 m Using the WebGUI See Section 2 2 5 Configuring the IP Address Using the WebGUI on page 2 11 Viewing the ILOM IP Address To find the ILOM IP address 1 Log in to the ILOM CLI using any of the methods described in Section 2 1 Connecting to the ILOM on page 2 1 To use the Ethernet ssh connection you must already know the IP address 2 Type the command Chapter 2 Connecting and Initial Setup 2 7 2 2 2 m To see all the IP address related information type show SP network m To see only the IP address type show SP network ipaddress Using DHCP to Assign an IP Address Most installations use DHCP to assign an IP address to the ILOM To use DHCP the following conditions must be present a A DHCP server must be connected to the same subnet as the ILOM a The DHCP server must be configured to accept new MAC addresses a The ILOM must be configured to use DHCP This is its default setting If the ILOM is not configured to use DHCP you can config
181. you can configure eight additional accounts Each user account consists of a user name a password and a role Caution The ILOM includes a user account called sunservice which shares the ILOM root password Normally it is used exclusively by Sun Service personnel however it can also be used to perform recovery procedures documented in the product notes Incorrect use of this account can corrupt the service processor image or operations The roles include a Administrator Enables access to all ILOM features functions and commands Operator Enables limited access to ILOM features functions and commands In general operators cannot change configuration settings Operators cannot a See or change LDAP settings a See or change RADIUS settings 5 1 a Add or remove users a Change network settings view only a Change Network Time Protocol NTP settings view only a Change SNMP settings view only a Change HTTP settings view only 5 2 TAAN 3 22 5 2 3 Managing User Accounts Using the CLI This section describes how to add modify and delete user accounts using the CLI Adding a User Account Type the following command to add a local user account create SP users username password password role administrator operator Only accounts with administrator privileges are allowed to add modify or delete user accounts However operators can modify their own password Deleting a User Acc
Download Pdf Manuals
Related Search
Related Contents
Tracer-BN Series Dacor ILb8 User's Manual NetDVR 4.6 User Manual Minuta de Procedimento Dimensions / Manual / Application Iomagic IBD1 StarTech.com 3 ft Cat5e Red Snagless Crossover RJ45 UTP Cat5e Patch Cable 3ft Patch Cord Bogart SE - MacroSystem Digital Video AG CBECC-RES - Bruce A. Wilcox, PE Copyright © All rights reserved.