Sun Fire V210 and V240 Servers Installation Guide
Contents
1. 24 Sun Fire V210 and V240 Servers Installation Guide November 2005
2. Solaris media kit optional The Solaris OS media kit includes several CDs containing software to help you operate configure and administer your server See the documentation provided with the media kit for a complete listing of included software and detailed installation instructions Sun Fire V210 and V240 Servers Installation Guide November 2005 Verifying the Contents of the Shipping Kit The server is supplied with several components Make sure that all the parts are present in the shipping kit If any components are missing contact your Sun sales representative m Rackmount kit m Cat5 RJ 45 cable m Accessories kit m System key V240 server only Antistatic wrist strap RJ 45 to DB 9 adapter RJ 45 to DB 25 adapter Sun product documentation Note The contents of the shipping kit might vary depending on any options you ordered Make sure that all the basic parts as described in the list are present in the shipping kit Using the Sun Advanced Lights Out Manager Software The Sun Fire V210 and V240 servers ship with the Sun Advanced Lights Out Manager ALOM software installed The system console is directed to ALOM by default and is configured to show server console information on startup ALOM enables you to monitor and control your server over either a serial connection using the SERIAL MGT port or an Ethernet connection using the NET MGT port Note The ALOM serial port labelled SERIAL MGT is
3. for server management only If you need a general purpose serial port use the serial port labeled 10101 ALOM can be configured to send email notification of hardware failures and other events related to the server or to ALOM Chapter 1 Introduction to the Sun Fire V210 and V240 Servers Installation 3 The ALOM circuitry uses standby power from the server This means that m ALOM is active as soon as the server is connected to a power source and remains active until power is removed by unplugging the power cable m ALOM continues to be effective even when the operating system is offline and when the server is in Standby mode For more information about ALOM see the Sun Advanced Lights Out Management User s Guide 4 Sun Fire V210 and V240 Servers Installation Guide November 2005 CHAPTER 2 Installing the Hardware This chapter describes how to mount the Sun Fire V210 and V240 servers into a rack and attach the cables It includes the following sections m Rackmounting Kit Contents on page 5 m Compatible Racks on page 5 m Installing the Slide Rails on page 6 m Installing the Cable Management Arm on page 10 Rackmounting Kit Contents The rackmount kit consists of the following components Slide assemblies Spacer tool Cable management arm a a E m Screw kit Compatible Racks The slide rail kit enables you to mount the server into a Sun rack For a complete listing of comp
4. that shipped with prior Sun Fire V210 and V240 servers See Installing the Slide Rails on page 6 for specific instructions Install the optional components if any shipped with your server This instruction guide does not cover the installation of optional components For those instructions see the Sun Fire V210 and V240 Servers Administration Guide Set up a console to communicate with the server You can communicate with the Sun Fire server using either a Tip connection from another server or an ASCII terminal connected to the SERIAL MGT port To set up the console refer to the Sun Fire V210 and V240 Servers Adminstration Guide Power on and configure the server The Solaris 10 Operating System Solaris OS and the Java Enterprise System are preinstalled on the server When you power the server on you will automatically be taken through the Solaris OS configuration procedure However you must first go to the preinstalled software site for the latest updates and patches To power the server on and configure the preinstalled software see Powering On the Server on page 17 Set the desired OpenBoot PROM configuration options The initial boot will test the entire system You can change the level of testing by using the OpenBoot PROM commands and configuration variables To change the boot test level and other boot variables see the OpenBoot PROM Enhancements Operations Load additional software from the
5. the Server s Details Registered at a Name Server Note Follow the instructions in this section only if you have a name server installed on your network For instructions on using a name server to automate the process of configuring the Solaris operating environment on multiple servers refer to the Solaris Advanced Installation Guide that accompanies the Solaris operating environment CDs During booting you will be prompted for certain information The information you provide determines the configuration of the server 1 Specify the type of terminal with which you are communicating with the server 2 Specify whether you need IPv6 enabled and then follow the instructions on the screen 20 Sun Fire V210 and V240 Servers Installation Guide November 2005 10 11 Specify whether you want to enable the Kerberos Security mechanism and then follow the instructions on the screen When prompted give a password if any for users logging in as root To Configure Without the Server s Details Registered at a Name Server Follow the instructions in this section if you do not have a Name Server configured on your network Tip Read these instructions through before you follow them to see what information the system will prompt you for when you start it for the first time During booting you will be prompted for certain information The information you provide determines the configuration of the server
6. the server Refer to the Sun Fire V210 and V240 Servers Administration Guide for instructions on how to set up a console session Chapter 3 Powering On and Configuring the Server 19 Configuring the Server The Sun Fire server ships with the Solaris 10 OS and the Java Enterprise System preinstalled on the hard drive When you power on the server for the first time a series of questions lead you through the configuration procedure This procedure consists of a number of questions The answers you give determine how the server is configured With the release of OpenBoot PROM 4 16 2 diagnostics are enabled by default This ensures complete diagnostic test coverage on the initial boot and after error or reset events This change results in increased boot time To change the diagnostic settings after the initial boot and after you configure the server for the first time refer to the OpenBoot PROM Enhancements for Diagnostic Operation in the shipping kit Choose the configuration that best suits your requirements from the list below and follow the instructions in the appropriate section to power on and configure your server m To Configure With the Server s Details Registered at a Name Server on page 20 m To Configure Without the Server s Details Registered at a Name Server on page 21 m To Configure a Standalone Server for the First Time on page 22 m To Clear the Configuration on page 22 v To Configure With
7. v To Attach the slide rail Assemblies to the Rack 1 Position a slide rail assembly in your rack so that the brackets at each end of the slide rail assembly are on the outside of the front and rear rack posts as depicted in FIGURE 2 2 2 Attach the slide rail assembly to the rack posts The method used to attach the slide rails varies depending on the type of rack m If your rack has threaded mounting holes in the rack posts determine whether the threads are metric or standard then insert the correct mounting screws through the slide rail brackets and into the threaded holes m If your rack does not have threaded mounting holes insert the mounting screws through both the slide rail brackets and rack posts then secure them with the caged nuts FIGURE 2 2 Slide Rail Assembly Mounting to Rack Post 3 Repeat for the remaining slide rail assembly 8 Sun Fire V210 and V240 Servers Installation Guide November 2005 To Install the Server Into the Slide Rail Assemblies Caution This procedure requires a minimum of two people because of the weight of the server Attempting this procedure alone could result in equipment damage or personal injury Push the slide rails into the slide rail assemblies as far as possible Raise the server so that the rear ends of the mounting brackets are aligned with the slide rail assemblies that are mounted in the equipment rack see FIGURE 2 3 Insert the mountin
8. 5 Compatible Racks 5 Installing the Slide Rails 6 v To Disassemble the Slide Rails 6 v To Install the Mounting Brackets Onto the Server 7 w To Attach the slide rail Assemblies to the Rack 8 v To Install the Server Into the Slide Rail Assemblies 8 Installing the Cable Management Arm 10 v To Install the Cable Management Assembly 10 v To Verify the Operation of the slide rails and CMA 12 Powering On and Configuring the Server 15 Understanding the Status Indicators 15 2 Powering On the Server 17 v To Power On From the Keyboard 17 v To Power On Using the On Standby Button 18 v To Power Off the System Using the On Standby Button 19 Configuring the Server 20 v To Configure With the Server s Details Registered at a Name Server 20 v To Configure Without the Server s Details Registered at a Name Server 21 v To Configure a Standalone Server for the First Time 22 Clearing Your Configuration 22 v To Clear the Configuration 22 Accessing the Sun Advanced Lights Out Manager Software 23 v To Display the ALOM Prompt 23 v To Display the Console Prompt 23 Sun Fire V210 and V240 Servers Installation Guide November 2005 Figures FIGURE 2 1 FIGURE 2 2 FIGURE 2 3 FIGURE 2 4 FIGURE 2 5 FIGURE 2 6 FIGURE 2 7 Disassembling the Slide Rail Before Installation 7 Slide Rail Assembly Mounting to Rack Post 8 Inserting the Server With Mounting Brackets Into the Slide Rails 9 Inserting the CMA Rail Extension Into the Rear of th
9. Online and accessories kit English only Online Online Online Online Accessories kit Online Documentation Support and Training Sun Function URL Documentation http www sun com documentation Support http www sun com support Training http www sun com training Third Party Web Sites Sun is not responsible for the availability of third party web sites mentioned in this document Sun does not endorse and is not responsible or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content goods or services that are available on or through such sites or resources Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun Fire V210 and V240 Servers Installation Guide part number 819 4209 10 Preface v vi Sun Fire V210 and V240 Servers Installation Guide November 2005 CHAPTER 1 Introduction to the Sun Fire V210 and V240 Servers Installation This chapter provides a description of the Sun Fire servers and gives an overview of the installation proc
10. Specify the type of terminal you are using to communicate with the server When asked if you want the server to be networked answer Yes You must manually specify an IP address when prompted Specify whether the IP address is to be configured by DHCP Specify which of the Ethernet ports you intend to use as the primary Ethernet connection Specify a host name for the server If prompted specify the IP address for the system The system prompts you for this address if you declined to use DHCP in Step 3 It also asks you whether the server is to be part of a subnet and if you answer Yes it prompts you to provide the netmask of the subnet Specify whether you need IPv6 enabled and then follow the instructions on the screen Specify whether you want to enable the Kerberos Security mechanism and then follow the instructions on the screen Specify the name service you want the server to use Specify the name of the domain of which the server will be a part Specify whether you want the system to search the network for a name server or whether you want it to use a particular name server Chapter 3 Powering On and Configuring the Server 21 12 13 14 15 If you chose to use a particular name server specify the host name and IP address of the name server At the name server create entries in the network administration files for the system you are setting up At the system you are setting
11. Sun Advanced Lights Out Manager ALOM software For detailed ALOM instructions and configuration information refer to the Sun Advanced Lights Out Manager User s Guide The ALOM software is preinstalled on the server and is ready to run as soon as power is applied to the server However you need to perform some basic configuration steps to customize the ALOM software to suit your application v To Display the ALOM Prompt 1 Type the default keystroke sequence Note When you switch to the ALOM prompt after initial poweron you will be logged in as the admin user and prompted to set a password You must set this password in order to execute certain commands 2 If you are prompted to do so set a password for the admin user The password must m Contain at least two alphabetic characters m Contain at least one numeric or one special character Chapter 3 Powering On and Configuring the Server 23 m Be at least six characters long After you set the password the admin user has full permissions and can execute all ALOM CLI commands v To Display the Console Prompt Type sc gt console More than one ALOM user can be connected to the server console stream at a time but only one user is permitted to type input characters to the console If another user is logged on and has write capability you will see the message below after issuing the console command sc gt Console session already in use view mode
12. allation Guide November 2005 TABLE 3 4 Network Speed Indicators LED Colour LED State Network Speed Status Green On The network link is established and running at its maximum supported speed Off e If the network link indicator is on the network link is established but not running at its maximum supported speed e If the network link indicator is off network link is not established Powering On the Server To power on the server you can use either the On Standby button located behind the front bezel or you can use the keyboard Powering on from the keyboard enables you to see system output as the server powers on Before you begin the procedures in this section make sure that the keyswitch is in the normal position This position allows the On Standby button to control the power state of the server For more information on the operation of the keyswitch see the Sun Fire V210 and V240 Servers Administration Guide The Sun Fire V210 server does not have a keyswitch To Power On From the Keyboard Connect the server to the power supply The server automatically goes into Standby power mode when it is connected to a power source Set up a connection to the SERIAL MGT port For details refer to the Sun Fire V210 and V240 Servers Administration Guide When you switch to the ALOM prompt after initial power on you will be logged in as the admin user and prompted to set a password You must set this password in
13. atible racks go to http www sun com servers gt Perform the procedures in this chapter in the order they are listed to install your server into a four post rack using the orderable slide rail option This set of slide rails has been designed to work with both the Sun Fire V210 and Sun Fire V240 servers These slide rails are compatible with a wide range of equipment racks that meet the following standards m Four post structure mounting at both front and rear Two post racks are not compatible m Rack horizontal opening and unit vertical pitch conforming to ANSI EIA 310 D 1992 or IEC 60927 standards m Distance between front and rear mounting planes between 610 mm and 915 mm 24 inches to 36 inches m Clearance depth to front cabinet door in front of front rackmounting plane at least 25 4 mm 1 inch m Clearance depth to rear cabinet door behind front rackmounting plane at least 800 mm 31 5 inches or 700 mm 27 5 inches without cable management arm m Clearance width between structural supports and cable troughs between front and back mounting planes at least 456 mm 18 inches Note Although the Sun Fire V210 server is pictured in the illustrations these procedures also apply to the Sun Fire V240 server Caution Always load equipment into a rack from the bottom up so that it will not become top heavy and tip over Deploy the anti tilt bar to prevent the rack from tipping during equipment insta
14. d one to observe the cables and CMA 1 Slowly pull the server out of the rack until the slide rails reach their stops 2 Inspect the attached cables for any binding or kinks 3 Verify that the CMA extends fully and does not bind in the slide rails 4 Push the server back into the rack as described below When the server is fully extended you must release two sets of slide rail stops to return the server to the rack Chapter 2 Installing the Hardware 13 a The first set of stops are levers located on the inside of each slide rail just behind the rear panel of the server These levers are labeled PUSH Push in both levers simultaneously and slide the server toward the rack The server travels approximately 15 inches 38 cm and stops Verify that the cables and the CMA retract without binding before continuing b The second set of stops are the slide rail release buttons located near the front of each mounting bracket See FIGURE 2 3 Simultaneously push or pull both of the slide rail release buttons and push the server completely into the rack until both slide rail locks engage 5 Adjust the cable hangers and CMA as required 14 Sun Fire V210 and V240 Servers Installation Guide November 2005 CHAPTER 3 Powering On and Configuring the Server This chapter tells you how to power on and configure the server to suit your application It contains the sections m Understanding the Status Indicators on pa
15. des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation grephique Xerox cette licence couvrant galement les licenci es de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON SA Ca Adobe PostScript Contents Preface i Introduction to the Sun Fire V210 and V240 Servers Installation 1 Previewing the Installation Process 1 Verifying the Contents of the Shipping Kit 3 Using the Sun Advanced Lights Out Manager Software 3 Installing the Hardware 5 Rackmounting Kit Contents
16. e Left slide rail 10 Inserting the CMA Mounting Bracket Into the Rear of the Right slide rail 11 Connecting the CMA Arm to Rail Extension Connector 11 Installing CMA Cable Hangers 12 2 Sun Fire V210 and V240 Servers Installation Guide November 2005 Tables TABLE 3 1 TABLE 3 2 TABLE 3 3 TABLE 3 4 Server Status Indicators 16 Hard Drive Indicators 16 Network Link Indicators 16 Network Speed Indicators 17 2 Sun Fire V210 and V240 Servers Installation Guide November 2005 Preface This document provides you with a detailed guide for rackmounting cabling and configuring the Sun Fire V210 and V240 servers Before You Read This Document Before you use the instructions in this document you must have prepared your site for the installation and read the latest product notes See these documents before you begin the installation process m Sun Fire V210 and V240 Servers Getting Started Guide m Sun Fire V210 and V240 Servers Product Notes m OpenBoot PROM Enhancements Diagnostics Operation m Sun Advanced Lights Out Manager User Guide See Related Documentation on page iv for links to these documents As you will read in the Sun Fire V210 and V240 Servers Getting Started Guide you must visit the Sun preinstalled software site for specific configuration instructions software updates and newly released patches You must have Internet access to perform this task If not contact your Sun support represen
17. ess The chapter contains the following sections m Previewing the Installation Process on page 1 m Verifying the Contents of the Shipping Kit on page 3 m Using the Sun Advanced Lights Out Manager Software on page 3 Previewing the Installation Process This section contains an overview of the installation process Each step in the procedure includes references to the appropriate instructions that you must complete Each step must be completed in order 1 Prepare the site for the power clearance and environmental requirements If you are installing the server into a new Sun rack you must fully prepare the site for the installation If you are installing the server into an existing rack you must conduct some site preparation to satisfy the additional power and environmental requirements Refer to the Sun Fire V210 and V240 Getting Started Guide for specific instructions 2 Verify that you have received all of the components The Sun Fire server ships in several packages See Verifying the Contents of the Shipping Kit on page 3 for a list of the shipping kit 3 Install the server into the rack 2 The installation of the rack slides and cable management arm CMA represent the majority of physical work described in this guide This release of the Sun Fire servers includes new rack slides so the slide installation differs greatly from prior releases In addition this guide replaces the rackmounting poster
18. g brackets into the slide rails then push the server into the rack until the mounting brackets encounter the slide rail stops approximately 12 in or 30 cm FIGURE 2 3 Inserting the Server With Mounting Brackets Into the Slide Rails Chapter 2 Installing the Hardware 9 4 Simultaneously pull and hold the slide rail release buttons on each mounting bracket while you push the server into the rack see FIGURE 2 3 5 Continue pushing until the slide rail locks on the front of the mounting brackets engage the slide rail assemblies Caution Verify that the server is securely mounted in the rack and that the slide rails locks are engaged with the mounting brackets before continuing Installing the Cable Management Arm The section contains procedures to install the optional cable management assembly CMA to route and attach the cables and to verify the operation of the CMA v To Install the Cable Management Assembly 1 Unpack the CMA parts 2 Take the CMA to the rear of the equipment rack and ensure that you have adequate room to work around the rear of the server Note References to left or right in this procedure assume that you are facing the rear of the equipment rack 3 Locate the CMA rail extension and insert it into the left slide rail until the extension locks into place with an audible click FIGURE 2 4 10 Sun Fire V210 and V240 Servers Installation Guide Novembe
19. ge 15 Powering On the Server on page 17 m Configuring the Server on page 20 m Accessing the Sun Advanced Lights Out Manager Software on page 23 Understanding the Status Indicators Before you power on the server you should become familiar with the LED indicators associated with the server itself and with various components The server status indicators are located on the bezel and repeated on the back panel The components with LED indicators to convey status are power supply units Ethernet ports and hard disk drives TABLE 3 1 contains explanations of the indicators TABLE 3 1 Server Status Indicators Indicator LED Colour LED State Meaning Activity Green On The server is powered on and running the Solaris OS Off Either power is not present or the Solaris OS is not running Service Yellow On The server has detected a problem and Required requires the attention of service personnel Off The server has no detected faults Locator White On Identifies the server from others in a rack TABLE 3 2 Hard Drive Indicators Indicator LED Colour LED State Component Status Activity Green Flashing Active SCSI transactions Off No activity Ready to Blue On Ready to remove remove Off Not ready to remove TABLE 3 3 Network Link Indicators LED Colour LED State Network Link Status Green On Link is established Blinking Link is transferring data Off Link is not established 16 Sun Fire V210 and V240 Servers Inst
20. iagnostics position 5 Press the On Standby button 18 Sun Fire V210 and V240 Servers Installation Guide November 2005 6 Sun Fire V240 only a Turn the keyswitch to the Locked position This prevents anyone from accidentally powering off the system b Remove the system key from the keyswitch and store it in a secure place 7 Close the front bezel v To Power Off the System Using the On Standby Button Note Applications running on the Solaris OS can be adversely affected by a poorly executed system shutdown Make sure you have gracefully shut down any applications before powering off the system 1 Notify users that the system will be powered down 2 Back up the system files and data if necessary 3 Sun Fire V240 only Ensure that the keyswitch is in the Normal or Diagnostics position 4 Press and release the On Standby button behind the front bezel The system begins an orderly software system shutdown Note Pressing and releasing the On Standby button initiates an orderly software shutdown Pressing and holding the switch for four seconds causes an immediate hardware shutdown Whenever possible initiate an orderly shutdown Forcing an immediate hardware shutdown can corrupt the disk drive and cause loss of data 5 Wait for the front panel green LED to go out 6 Sun Fire V240 only Remove the system key from the keyswitch and store it in a secure place 7 Set up a console session to
21. llation Installing the Slide Rails The procedures in this section contain instructions to install the slide rail assemblies to the rack and the server chassis with mounting brackets into the slide rail assemblies that are mounted to the rack v To Disassemble the Slide Rails 1 Unpack the slide rails 6 Sun Fire V210 and V240 Servers Installation Guide November 2005 2 Locate the slide rail lock at the front of one of the slide rail assemblies as shown in FIGURE 2 1 3 Squeeze and hold the tabs at the top and bottom of the lock while you pull the mounting bracket out of the slide rail assembly until it reaches the stop See FIGURE 2 1 4 Pull the mounting bracket release button toward the front of the mounting bracket as shown in FIGURE 2 1 and simultaneously withdraw the mounting bracket from the slide rail assembly 5 Repeat for the remaining slide rail assembly Mounting bracket slide rail lock release button FIGURE 2 1 Disassembling the Slide Rail Before Installation Chapter 2 Installing the Hardware 7 v To Install the Mounting Brackets Onto the Server 1 Position a mounting bracket against the chassis so that the slide rail lock is at the server front and the three keyed openings on the mounting bracket are aligned with the three screw holes on the side of the chassis 2 Attach the slide rail onto the server with the supplied screws 3 Repeat Steps 1 and 2 to install the other slide rail
22. o list all files computer output You have mail AaBbCc123 What you type when contrasted su with on screen computer output password AaBbCc123 Book titles new words or terms Read Chapter 6 in the User s Guide words to be emphasized Replace command line variables with real names or values These are called class options You must be superuser to do this To delete a file type rm filename The settings on your browser might differ from these settings Preface Related Documentation The documents listed as online are available at http www sun com products n solutions hardware docs Application Getting Started Administratio n Service Safety and Compliance Late breaking news OpenBoot PROM ALOM Title Sun Fire V210 and V2420 Servers Getting Started Guide Sun Fire V210 and V240 Servers Administration Guide Sun Fire V210 and V40 Servers Service Manual Sun Fire V210 and V240 Safety and Compliance Manual Sun Fire V210 and V240 Servers Product Notes OpenBoot PROM Enhancements for Diagnostic Operation Sun Advanced Lights Out Manager User s Guide Part Number 819 4206 819 4208 819 4207 817 4827 819 4205 817 6957 817 5481 iv Sun Fire V210 and V240 Servers Installation Guide November 2005 Format PDF HTML and hard copy PDF and HTML PDF and HTML PDF and HTML PDF and HTML Hard copy PDF and HTML Location
23. order to execute certain commands Chapter 3 Powering On and Configuring the Server 17 3 If you are prompted to do so set a password for the admin user The password must m Contain at least two alphabetic characters m Contain at least one numeric or one special character m Be at least six characters long Once the password is set the admin user has full permissions and can execute all ALOM command line interface CLI commands 4 Turn on power to any peripherals and external storage devices you have connected to the server Read the documentation supplied with the device for specific instructions 5 At the console prompt type the following command to power on the server sc gt poweron 6 At the console prompt type the following to access the server sc gt console v To Power On Using the On Standby Button Caution Never move the system when the system power is on Movement can cause catastrophic hard drive failure Always power off the system before moving it 1 Connect the server to the power supply The server automatically goes into Standby power mode when it is connected to a power source 2 Turn on power to any peripherals and external storage devices you have connected to the server Read the documentation supplied with the device for specific instructions o Open the front bezel 4 Sun Fire V240 only Insert the system key into the keyswitch and set it to the Normal or D
24. r 2005 FIGURE 2 4 Inserting the CMA Rail Extension Into the Rear of the Left slide rail Note Support the CMA in the remaining installation steps Do not allow the assembly to hang by its own weight until it is secured by all three of the attachment points Chapter 2 Installing the Hardware 11 4 Insert the CMA s mounting bracket connector into the right slide rail until the connector locks into place with an audible click FIGURE 2 5 FIGURE 2 5 Inserting the CMA Mounting Bracket Into the Rear of the Right slide rail 5 Insert the remaining CMA arm connector into the plastic cutout on the CMA rail extension FIGURE 2 6 FIGURE 2 6 Connecting the CMA Arm to Rail Extension Connector 12 Sun Fire V210 and V240 Servers Installation Guide November 2005 6 Position the cable hangers in the appropriate mounting holes in the CMA and snap them into place FIGURE 2 7 FIGURE 2 7 Installing CMA Cable Hangers 7 Install the cables to the server as required Refer to the Sun Fire V210 and V240 Servers Getting Started Guide for information about the locations of the power inlets and I O ports on the front and back of the servers 8 Route the cables through the CMA cable hangers v To Verify the Operation of the slide rails and CMA Note Two people are recommended for this procedure one to move the server in and out of the rack an
25. s de propriete intellectuels relatants la technologie qui est d crit dans ce document En particulier et sans la limitation ces droits de propri t intellectuels peuvent inclure un ou plus des brevets am ricains num r s a http www sun com patents et un ou les brevets plus suppl mentaires ou les applications de brevet en attente dans les Etats Unis et dans les autres pays Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y ena Le logiciel d tenu par des tiers et quicomprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Sun Fire Java OpenBoot et Solaris sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou
26. sS R SUN microsystems Sun Fire V210 and V240 Servers Installation Guide Sun Microsystems Inc www sun com Part No 819 4209 10 November 2005 Revision A Submit comments about this document at http www sun com hwdocs feedback Copyright 2005 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology fiat is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the s produet may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Sun Fire Java OpenBoot and Solaris are trademarks or registered
27. tative for a copy of the instructions updates and patches How This Document Is Organized Chapter 1 contains a description of the installation process a list of the contents of the shipping kit and an overview on using the Sun Advanced Lights Out Manager software Chapter 2 contains a list of the rack mounting kit a list of compatible racks and instructions for mounting the server into the rack installing the cable management arm cabling the server and verifying the installation Chapter 3 contains an overview of the status indicators and instructions for powering on the server connecting a console and configuring the preinstalled software Using UNIX Commands This document might not contain information about basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices Refer to the following for this information m Software documentation that you received with your system a Solaris Operating System documentation which is at http docs sun com Sun Fire V210 and V240 Servers Installation Guide November 2005 Shell Prompts Shell Prompt C shell C shell superuser Bourne shell and Korn shell Bourne shell and Korn shell superuser machine name machine name Typographic Conventions Typeface Meaning Examples AaBbCc123 The names of commands files Edit your login file and directories on screen Use 1s a t
28. trademarks of Sun Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the Sompatie industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2005 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droit
29. up follow the prompts to provide time and date information When prompted give a password if any for users logging in as superuser To Configure a Standalone Server for the First Time Specify the type of terminal you are using to communicate with the server When prompted to indicate whether you want the server to be networked specify No Specify a Host Name for the server Confirm the information you have given Specify the date and time information When prompted give a password if any for users logging in as root Clearing Your Configuration If you want to start the power on process again as if from a previously unused server you must clear the configuration of the server To Clear the Configuration At the Solaris OS prompt type sys unconfig When prompted to confirm that you want to create a blank server type y 22 Sun Fire V210 and V240 Servers Installation Guide November 2005 3 When the OpenBoot PROM prompt appears type ok gt boot 4 Follow the instructions in one of the following sections m To Configure With the Server s Details Registered at a Name Server on page 20 m To Configure Without the Server s Details Registered at a Name Server on page 21 m To Configure a Standalone Server for the First Time on page 22 Accessing the Sun Advanced Lights Out Manager Software This section contains a brief introduction to the
Download Pdf Manuals
Related Search
Related Contents
version PDF - Flash informatique Copyright © All rights reserved.
Failed to retrieve file