Home
manual
Contents
1. inthe kitchen laundry room bathroom and spa exercise areas that have exces sive moisture The bucket must be placed in the proper position for the dehumidifier to work The Bucket Full light will flash and the dehumidifier will not run if the bucket is not in the proper position Dehumidifier settings can not be changed when the bucket is not in its proper position e The dehumidifier fan will shut off in 3 minutes once the desired humidity set ting is reached plus or minus 5 Rela tive Humidity RH to prevent moisture damage anywhere books or valuables are stored e during construction or remodeling to reduce drying time for drywall and paint However check and clean filter often A WARNING To reduce the risk of fire electric shock or injury to persons read the important SAFETY IN STRUCTIONS found on page 3 before operating this appliance KEY FEATURES Washable Filter Enclosur Continuous Drain i Connector Door Dehumidifier Power Cord NA lt 16 ft Pump Drain Hose 3 ft J Dehumidifier Hose Pal ka E ie Vertical fre eee pee Pump Le Bucket Power Cord Caster CONTROL PANEL 7 8 9 10 11 12 13 HUMIDITYS O 4m H a BUCKET FEL CONTINUOUS O 25 O MID a a POWER ALTER RESET baie wile ema ea nes ie Unie KEKE aNS Ge Dae T eeu yee eek es Seen E N bE E E eee PEE Co Ce A gt EEE CoG EEE i ee
2. by pushing small clamp forward towards the pump Fig 14 FIG 14 Step 5 Secure hose by pushing small clamp forward towards the pump Fig 15 FIG 15 Step 6 Insert the angled end of the dehumidifier drain hose into the water pump tank Fig 16 FIG 16 11
3. hose connection See the Drain loose age Section Disconnect the hose if using the bucket or place the hose near a drain Normal Compressor and electric motor discharge nominal heat Re install the dehumidifier drainage joint and hose according to the manual Flatten the hose or remove blockage Re install the pump drain hose according to the manual Flatten the hose or remove blockage TROUBLESHOOTING WATER DISPOSING OPTIONS Problem Possible Causes Dehumidifier does not The dehumidifier is un start plugged The fuse is blown circuit breaker is tripped Dehumidifier has reached the user set humidity level or the bucket is full Bucket is not in the proper position Power Failure Dehumidifier is not oper Not enough time allowed ating as for unit to remove moisture Intended Airflow is restricted Dirty filter The user set Humidity Level may not be set low enough Doors and windows may not be closed tightly Water is not draining through drain hose Room temperature is too low Filter Indicator is lit Filter needs to be cleaned every 250 hours of use 14 Make sure the dehumidifier s plug is pushed com pletely into the outlet Check the house fuse circuit breaker box and replace fuse or reset breaker The dehumidifier automatically turns off when either condition occurs Change to a lower setting or empty the water bucket and replace properly The bucket
4. i ll i GBEMBEeBHERERoeRE HOB REERE SF oOmeeaeeteaertseeaEeese SN a 4 5 2 POWER ON OFF 1 Once the unit is plugged in the POWER INDICA TOR 10 will light Pressing the POWER button once will turn the unit ON and illuminate the digi tal display 9 The fan will operate for 3 minutes to draw air through the dehumidifier to properly sense relative humidity The display will show the humidity level of the room in 5 increments down to a minimum of 25 Pressing the Power button again will turn the display OFF and the unit will cease operating HUMIDITY LEVEL 2 3 The humidity level can be set in 5 increments in a range from 35 to 80 The humidity setting is shown in the digital display When the humid ity level of the room reaches the set level the compressor will stop but the fan will continue operating for 3 minutes To set the unit to continu ous operation press the a arrow button until the display shows 35 Press again and the dis play will show CO The Continuous indicator 13 will light up on the control panel To leave con tinuous operation press the 3 arrow To check the current humidity setting press the and arrow The display will show and set 5 above or below the current settings FAN SPEED 5 Press Fan Speed to toggle between Low Med and High fan speeds Speed will be shown in FAN SPEED INDICATOR 8 BUCKET FULL INDICATOR 11 Whe
5. DRAIN PUMP l e Plug into grounded electrical outlet 2 Place the other end of the pump hose where you would like to empty the wa ter floor drain water container or through a basement window The pump will automatically start and begin pumping the water that drains into it Check hose for kinks or other obstructions 3 Before and after each use check hose connections to make sure they are properly secured 12 INSTALLING THE GRAVITY DRAIN HOSE Step 4 Insert the drain hose onto the drainage joint so that it is fully seated Fig 9 FIG 9 10 FIG 10 Step 6 Place bucket in the dehumidifier for operation Fig 11 FIG 11 INSTALLING THE EXTERNAL PUMP INSTALLING THE EXTERNAL PUMP OPTION 3 EXTERNAL VERTICAL PUMP INSTALLING THE EXTERNAL PUMP Step 1 To install Dehumidifier Drain Hose refer to Gravity Drain Using Dehumidifier Hose instructions starting on page 9 Step 2 For optimal operation it is recommended that the pump is placed on a flat and level location Attach the water pump to a wall or other perpendicular flat surface with the included screws for security Fig 12 i Ya Bi Seen FIG 12 Step 3 Remove red cap from drain hose connector on pump Attach the small drain hose clamp onto the pump drain hose Fig 13 a Ais ADE p a ae FIG 13 10 Step 4 Insert pump drain hose onto pump connector until it is fully seated Secure hose
6. ER 6 key up to 5 seconds to reset the filter indicator IMPORTANT e Once the set humidity level is reached the compressor will shut off The fan will con tinue to run for up to 3 minutes e Anytime the compressor stops running for any reason it will not restart for a minimum of 3 minutes This is a design feature to pro tect the compressor from damage TROUBLESHOOTING Cont The area to be dehumidified is too large Doors and windows are open The dehumidifier has recently been turned on or the room temperature is below 41 F Dehumidifier runs too much Frost appears on the coils Bucket is full or it has been removed Controls cannot be set The capacity of your dehumidifier may not be adequate for the room size Close all doors and windows to the out side This is normal Frost will usually disappear within 60 minutes Empty bucket and install properly in unit i unit Water on the floor Hose is attached but not draining into a drain Unit is discharging warm air Check the drainage joint and hose on the dehumidi Water does not drain through the dehumidifier drain hose fier Is it installed correctly Check the drain hose for kinks or obstructions Check the pump drain hose on the pump Is it installed correctly Water does not drain through the pump drain hose Check the pump drain hose for kinks or obstruc tions 15 Hose connection may be Check the
7. SOLEUSAIE rawar by e GREE ADDRESS Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 WEBSITE www soleusair com 888 876 5387 ENERGY STAR Powered by e OGR EE SG DEH 70EP 2 Portable Dehumidifier with External Pump Operating Instructions V 130424 TABLE OF CONTENTS NOTES PACKAGE Contents scidssssisssezecsscacsceenssscsvsiosdseasosts 2 Installing the External Pump 005 10 11 ALERE ILID aces RE I E O NET 2 Using the PUM D lt sid ve taney wees eee an2 Safety INStrUCTIONS sciaient 3 Care and Maintenance ccececee cocer 13 Electrical Requirements cssscccsssssesssseeees A Troubleshooting ccsssccssssccssssreeesssseee o oeee 14 15 Installation ss tev ccoccsacccexcsevuseaeees oncxevecsvesonteorss tes 45 Error Codes deea larin aea Key FECTS evessaio oen eat 5 Product Specifications ssessessssoesoe 16 17 ConmirolPaneliisisene en 6 Water Disposing Options ccssssscssssrree Installing the Gravity Drain Hose 0000 8 9 PACKAGE CONTENTS e Dehumidifier e External Vertical Pump e 3 ft Dehumidifier Drain Hose e 16 ft Pump Drain Hose Drain Joint 2 Hose Clamps 2 Screws e Use amp Care Guide WARRANTY Soleus International Inc warrants the accompanying Soleus Air Powered by Gree Dehumidifier to be free of defects in material and workmanship for the applications specified in its operation instruction for a period
8. area you want to dehumidify It is not designed to dehumidify the entire house e For proper operation the dehumidifier should only be placed on a level floor e Close all doors windows and other open ings to the room The dehumidifier must operate in an enclosed area to be effec tive e To clean use a soft cloth do not use wax thinners or strong detergents as they may change the color of the unit or cause surface damage e Be sure to replace the bucket properly after emptying to prevent water from collecting on the floor causing damage to some types of flooring e Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant e Operation without filter will cause unit failure Insert the filter securely Clean it every two weeks See Care and Mainte nance section in this manual ELECTRICAL REQUIREMENTS EXTERNAL VERTICAL PUMP OBSERVE ALL LOCAL CODES AND ORDI NANCES DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER SUPPLY CORD GROUND PRONG ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE A 115 VOLT 60Hz AC ONLY 15A FUSED AND PROPERLY GROUNDED ELECTRICAL SUPPLY IS REQUIRED A time delay fuse or time delay circuit breaker is recommended Use a dedicated 3 prong grounded plug Power supply cord Grounded 3 prong electrical outlet circuit serving only this appliance RECOMMENDED GROUNDING METHOD For your personal safety this appliance m
9. coils Pump capacity per 24 hours 304 pints per day Rated Current Amps Dehumidifier Drain Hose Diameter Pump Drain Hose Inside Diameter 17 50 in 13 mm 20 in 5mm ERROR CODES Error Code Error Type Possible Cause Corrective Action Ambient Tem 1 Sudden Change in perature Sensor the surrounding Malfunction temperature Unplug the dehumidifier Check the surrounding area for possible reasons for sudden temperature changes Wait 30 minutes before plug ging the dehumidifier back in for normal operation If the Error is still indicated perature please contact your nearest Sensor Mal service center Call 888 876 function 5387 for service center locations 2 Faulty Sensor Pipe Tem PRODUCT SPECIFICATIONS ITEM SG DEH 7OEP 2 Reference Number Power Consumption W DP2 70EP 03 70 Pints per day 32 9 Liters per day 745 Watts Bucket Capacity 17 Pints 8 Liters 45 47 49 dB A Rated Current Amps Sound Pressure Level dB L M H Dimensions W x D x H 15 125 x 11 5 x 24 125 16 CHOOSING THE PROPER LOCATION AUTOMATIC SHUT OFF When the bucket is full or when the bucket has been removed the compres sor will automatically stop The fan will in the basement to help prevent moisture continue to run to dehumidify for 3 min damage utes Then the Bucket Full indicator will flash and you will hear a ten second audible alarm Use the dehumidifier
10. er Fig 3 NOTE Dehumidifier will not work and settings can not be changed when the BUCKET FULL indicator light is flashing or without the bucket properly installed DO NOT REMOVE THE STYROFOAM IN THE BUCKET This dehumidifier is equipped with a reliable Styrofoam float system The Styrofoam located inside the float in the bucket is essential to the bucket full system working properly Do not remove the Styrofoam from the float INSTALLING THE GRAVITY DRAIN HOSE Option 2 GRAVITY DRAIN HOSE Step 1 Open the drain connector door Fig 6 Step 2 Install and secure the drainage joint onto the drain connector Fig 7 FIG 7 FIG 8 CARE AND MAINTENANCE CLEANING THE AIR FILTER After 250 hours of operation the FILTER RESET indicator will light up to remind you to clean and change the air filter It is recommended to periodically check the filter for excess dirt even if the FILTER RESET indicator is off 1 To remove the air filter press the two filter tabs and pull the filter holder away from the back of the unit 2 Remove the filter and clean with warm soapy water Rinse and allow the filter to dry before placing back in the unit 3 Place the filter back into dehumidifier Plug unit back into outlet power the unit on and press and hold the FILTER key up to 5 seconds on the control panel to reset the filter setting NOTE DO NOT place the filter in a dish washer CAUTION DO NOT operate t
11. he dehumidi fier without a filter Doing so may cause a unit failure FILTER TABS A WARNING e Disconnect power supply cord from re ceptacle before performing any mainte nance CLEANING THE EXTERIOR Clean the cabinet using a damp cloth and a mild detergent Do not use bleach or abra sives CONTROL PANEL Wipe down the control panel with a dry cloth CLEANING THE BUCKET Every few weeks clean the dehumidifier bucket Partially fill the bucket with clean water and mild detergent Swish the mixture around in the bucket empty and rinse Re place the bucket when finished NOTE Do not place the bucket in a dish washer USING THE PUMP NOTE Make sure the drain hose is lower than the horizontal plane of the drain on the dehumidifier as seen in the illustration below Drain hose should be as short as possible and all kinks in the drain hose should be eliminated for proper pump opera tion 3ft Dehumidifier Drain Hose FIG 17 NOTE If you need to cut the dehumidifier drain hose only cut on the flat end of the hose Do not cut the angled end as it is designed for insertion into the pump d E A CUT DO NOT CUT 1 Remove flat end of the hose by squeezing the large clamp and pulling it to ward you 2 Remove hose from drainage joint and cut hose to appropriate length 3 Once cut is completed refer to installing the Drain Hose to re install dehu midifier drain hose USING THE
12. must be in place and securely seated for the dehumidifier to operate There is a protective time delay of 3 minutes to prevent tripping of the compressor overload For this reason the unit will not start normal dehumidifica tion for 3 min after it is powered back on When first installed allow at least 24 hours to achieve the desired humidity level Make sure there are no curtains blinds or furniture blocking the side or back of the dehumidifier See the Cleaning The Air Filter section To reduce moisture press the down arrow button to lower the percent humidity desired in the room or set the dehumidifier to CO for continuous operation Check that all doors windows and other openings are securely closed Make sure the drain is placed below the drain con nector nozzle to allow gravity to drain the water Refer to Gravity Drain Hose section in this manual Moisture removal is best at higher room tempera tures Lower room temperatures will reduce the moisture removal rate This model is designed to operate at temperatures above 41 F Once filter has been cleaned press the FILTER but ton for 3 seconds to turn the filter indicator off OPTION 1 EMPTYING MANUALLY 1 Pull out the bucket grasping the side handles Fig 1 2 Carry the bucket by grasping the front corner of the bucket with one hand and the back of the bucket with the other hand Fig 2 3 Empty the bucket and replace the bucket in the dehumidifi
13. n the collection bucket is full the BUCKET FULL indicator 11 will light up and you will hear an audible alarm The audible alarm will last up to ten seconds The dehumidifier will not run until the bucket is removed emptied and replaced 3 1 6 DELAY START 4 Unit can be programmed to turn on at a desired delay time by pressing the Timer 4 key When the unit is powered OFF press the timer key once for 2 hour delay start The 2 Hrs 7 timer indica tor will light up when the timer key is pressed Press the timer key once more for a 4 hour delay start The 4 Hrs 7 timer indicator will now light up Press the timer key a third time to clear the timer setting No timer indicators will light up when the timer setting is cleared AUTO SHUT OFF 4 Unit can be programmed to turn off at a desired time by pressing the Timer 4 key When the unit is powered ON press the timer key once for 2 hour automatic shut off The 2 Hrs 7 timer indi cator will light up when the timer key is pressed Press the timer key once more for a 4 hour auto matic shut off The 4 Hrs 7 timer indicator will now light up Press the timer key a third time to clear the timer setting No timer indicators will light up when the timer setting is cleared FILTER RESET 12 The FILTER RESET indicator 12 will light up when the filter needs cleaning Remove the filter and clean accordingly Replace the filter when fin ished and press and hold the FILT
14. of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use Soleus International will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As a condition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products pu
15. outlet Not grounding unit may cause electrical shock Unplug the unit if it emits strange sounds odors or smoke Do not use an electrical outlet if it is loose or damaged e Do not operate or plug in unit with wet hands or in a wet environment e Ventilate area before operating dehumidi fier Check for the presence of natural gas or the buildup of other combustible vapors e Do not clean the dehumidifier with water Water may enter the unit and degrade the insulation resulting in an electrical shock f water enters the product turn off the dehumidifier s power switch then unplug the unit Do not plug in unit until it has been inspected by an authorized repair service Because the fan rotates at high speed dur ing operation always unplug dehumidifier before attempting any recommended main tenance or cleaning e Do not block the inlet or outlet It may cause unit to fail or to operate inefficiently e Do not remove plug from outlet by pull ing on the cord e When not in use turning the unit off will save energy Unplug the dehumidifier when not using for long periods of time e When removing the filter be aware that some metal parts may have sharp edges and may cause injury e Do not use the water collected in the bucket for drinking purposes It is not sanitary and could cause illness e Do not allow children to play with this product Tips e Make sure the dehumidifier is the correct size for the
16. rchased from our authorized dealers or retailers It does not cover used salvaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support and Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 www soleusair com www soleusgreen com www greeusa com 2 19 NOTES 18 SAFETY INSTRUCTIONS IMPORTANT CAUTIONS FOR USING YOUR DEHUMIDIFIER To reduce the risk of fire electrical shock injury or damage to the dehumidifiers these safety precautions must be followed Safety e Do not place the power cord near a heater e Do not use an electrical outlet near flam mable or combustible materials such as gasoline propane paint thinners etc e Do not disassemble or modify dehumidifier parts or components It may cause electric shock and failure e Plug in the power cord properly e Do not turn the unit on and off by inserting or pulling out the power plug Do not damage the power cord or use an unspecified power cord Do not modify power cord length e Do not share the outlet with another appli ance e Always plug into a grounded
17. ust be grounded This appliance has a power supply cord with a 3 prong grounded plug To minimize possible shock hazard the cord must be plugged into a matching grounded electrical outlet that complies with the latest edition of the National Electrical Codes and all local codes and ordinances If a grounded 3 prong electrical outlet is not available it is the personal responsibil ity and obligation of the customer to have one installed by a qualified electrician k ELECTRICAL SHOCK HAZARD e Plug into a grounded 3 prong outlet e Do not remove the ground pin from the plug e Do not use an adapter e Do not use an extension cord e Failure to follow these instructions can result in death fire or electrical shock INSTALLING YOUR DEHUMIDIFIER e Install the dehumidifier on a level floor strong enough to support the unit with a full bucket of water e For best performance allow at least 12 18 inches of air space on all sides of the unit for good air circulation e Keep all outside doors windows and other openings closed when operating the dehu midifier Humid outdoor air will add to the unit s workload e Leave the dehumidifier in an upright posi tion for 30 minutes before turning on DEFROST OPERATION The dehumidifier has a built in defrost control that senses frost buildup on the evaporator coils During defrosting the compressor will automatically turn off the fan will continue running to defrost the