1. presentation system It is ideal for use together with Altinex computer video interfaces The PNP202 Interconnect Box can either pop up into a raised position to provide access to connectors or it can be lowered into a table when not in use Using a tower type construction with pneumatic suspension and an electromagnetic latching mechanism does this The PNP202 provides easy access to system inputs when they are needed It also removes system inputs when not needed eliminating the obstruction The PNP202 Interconnect Box has two input plates on either side of the unit servicing both sides of a table Each standard plate offers Computer Video 15 pin HD Composite Video RCA Audio RCA Computer Audio Stereo Mini Modem RJ 1 1 9 pin D type RS 232 and Network RJ 45 input connections All signals are passed through to a set of female connectors or cables Several optional connectors can be substituted for the standard set of connectors The PNP202 Interconnect Box is designed for use with tables ranging from one to three inches thick It offers an adjustable retaining ring to secure the unit flush with the table s surface The PNP202 comes in a standard matte black color The top of the unit can be finished to match the table or it can be painted another color This is available on a custom per order basis at an additional charge TECHNICAL SPECIFICATIONS 3 FEATURES DESCRIPTION PNP202 Front Panel Standard Con
2. 9 PIN CONNECTOR FOR COM PORT AC POWER CONNECTOR 5 295 Diagram 1 Diagram 1B SIDE VIEW SIDE VIEW closed PNP202 opened PNP202 Diagram 1C Diagram 1D a sia Y ZALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES PNP202 DIMENSIONS con t BACK VIEW Diagram 2 Back View OF PNP202 RCA CONNECTOR RCA CONNECTOR FOR VIDEO AUDIO LEFT RCA CONNECTOR COMP AUDIO AUDIO RIGHT 10 AMP BREAKER SWITCH FUSE BOX RJ 11 PHONE MODEM JACK 15 PIN CONNECTOR FOR COMPUTER VIDEO RJ 45 NETWORK AC POWER CONNECTOR 9 PIN CONNECTOR FOR COMP PORT APPLICATION DIAGRAM 5 Diagram 3 Application AC OUTLET IEC 320 M RCAF Tv MONTOR Hua RJ45M DB 9 F gt CONTROL WALL SYSTEM TELEPHONE JACK INTERFACE AUDIO 2 RCA F amp 3 POSITION OR AMPLIFIER JERMINAL BLOCK 15 PIN HD F gt DISTRIBUTION AMPLIFIER ALTINEX iem Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES Diagram 4 Final Installation PNP202 IN AN OPEN POSITION PASS THE POWER CORD THROUGH THE HOUSING AND ATTACH THE POWER CORD A SECURED SURFACE TABLE WITH A CABLE CLAMP ALTINE
3. repaired ALTINEX POLICY 10 10 1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service This warranty is limited to repairing at company s factory any part or parts of the product that shall within 2 years 90 days for cables from date of shipment to the purchaser be returned to company with transportation charges pre paid The company s examination shall disclose product s to be thus defective The warranty is expressly instead of all other warranties expressed or implied Altinex neither assumes nor authorizes any other person to assume for it any other liability concerning the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way SO as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 10 2 RETURN POLICY It is very important to Altinex that you receive all products that you have ordered and that this product fulfills your needs In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept all product returns for a period of 30 days from authorized Altinex dealers Products must be returned in an unopened package If a product has been opened the restocking fees will apply For the restocking fee please contact an Altinex Sa
4. ACCESSORIES MANUAL PART NUMBER 400 0109 001 PRODUCT REVISION 1 Interconnect Box USER S GUIDE ZALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 gt E mail solutions altinex com Web www altinex com ACCESSORIES INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated We are sure you wil find it reliable and simple to use Superior performance for the right price backed by solid technical and customer support is what Altinex has to offer The product you are holding in your hands is designed using state of the art technology and is superior to anything available on the market You will find this and our other products reliable long lasting and simple to operate We are committed to providing our customers with signal management solutions to the most demanding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers PNP202 Interconnect Box TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 ass 2 INSTALLATION 2 eZ cH 2 FCC ICE NOVICE 2 ABOUT YOUR 202 3 TECHNICAL SPECIFICATIONS 3 PNP202 DIM
5. ENSIONS 4 DIAGRAM 1 1B 1C amp 1D 4 5 APPLICATION DIAGRAM mee 5 DIAGRAM 3 8 5 ael 6 DIAGRAM 7 8 OPERA neres 9 LOCK RELEASE AND STATUS CONTROL u uuu uu u 9 HOW TO RELEASE AND REPLACE THE GAS SPRING T 9 CABLES AND ACCESSORIES 10 TROUBLESHOOTING GUIDE 11 ALTINEX POLICY 11 LIMITED WARRANTY re 11 RETURN POLICY 11 CONTACT INFORMATION 11 SALTINEX SiGNAL SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES PRECAUTIONS SAFETY WARNINGS L Please read this manual carefully before using your PNP202 Interconnect Box Keep this manual handy for future reference These safety instructions are to ensure the long life of your PNP202 and to prevent fire and shock hazard Please read them carefully and heed all warnings 1 1 GENERAL e Unauthorized personnel shall not open the unit since there are high voltage components inside e Qualified Altinex service personnel or their authorized representatives must perform all service 1 2 INSTALLATION e For best results place the PNP202
6. Interconnect Box in a dry area away from dust and moisture e To prevent fire or shock do not expose this unit to rain or moisture Do not place the PNP202 Interconnect Box in direct sunlight near heaters or heat radiating appliances or near any liquid Exposure to direct sunlight smoke or steam can harm internal components e Handle the PNP202 Interconnect Box carefully Dropping or jarring can damage internal components e Never place fingers inside the openings in the back of the unit This action could cause serious injury because of the sharp edges inside of the PNP202 Do not place heavy objects on top of the PNP202 Do not use excessive force to push down on the top of the unit To turn off main power disconnect the power cord which powers the power socket on the PNP202 pop up panels only and unplug the 12V 500mA power supply The power outlet socket should be installed as near to the equipment as possible and should be easily accessible We recommend using wall outlets with a Ground Fault Circuit Interrupter GFCI for maximum protection Install all cables according to the instructions Do not force or pull out any cable or power cord that is attached to the PNP202 Interconnect Box 1 3 CLEANING Surfaces should be cleaned with a dry cloth Never use strong detergents or solvents such as alcohol or thinner Do not use a wet cloth or water to clean the unit 1 4 FCC CE NOTICE This devic
7. MALE HD 15 xxx available length of 3ft 15ft 25ft 50ft 75ft 100ft 150ft 200ft 250ft SUPER HIGH RESOLUTION PLENUM FLEX MULTI CHANNEL COAX CABLE VGA MALE TO VGA FEMALE HD 15 xxx available length of 3ft 15ft 25ft 50ft 75ft 100ft 150ft 200ft 250ft 10 POWER CABLES IPC5301US Power Cable for US PC5302UK Power Cable for UK PC5303AU Power Cable Australia IPC5304GR Power Cable Germany OPTIONAL CONNECTORS Blank Connector Snap in 15 pin location BNC Female 4 Mini DIN 6 pin Mini DIN ALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SIGNAL MANAGEMENT SOLUTIONS ACCESSORIES TROUBLESHOOTING GUIDE 9 The PNP202 supplied unit was carefully tested and no problems were detected however we would like to offer these suggestions e Please make sure that the Fuse is of a 10 Amps rating e Please make sure that the highest quality video audio network and telephone cables or connectors are used e Make sure that the 12V DC adapter or the external regulated 12 volts is plugged into the power socket for proper operation e Make sure that no cable or power cord is damaged or pinched lf there has been damage then do not use the PNP202 unit Immediately contact the Altinex Customer Service Department to have the unit
8. SOLUTIONS ACCESSORIES Step 8 To lower the unit push on the top of the PNP202 until it fits into place When the 12V DC adapter is plugged in 12 volts must be applied Once the 12 volts have been applied the release top connection will be engaged This mechanism allows the unit to lock into place and then pop up when pressure is put on the top of the unit CONGRATULATIONS YOU ARE DONE ENJOY YOUR PNP202 Interconnect Box If you experience any problems please call 1 800 258 4623 or for international calls dial 1 714 990 2300 OPERATION 7 7 1 LOCK RELEASE STATUS CONTROL PINS To lock the position of the PNP202 connect the LOCK pin of the terminal block to GND Note the power supply is rated at 12V If a regulated power supply is used it should be a 12 volt power supply A regulated power supply is when the power supply is at 12 volts and when the power supply is at 9 volts itis known as unregulated To release the top connector assembly connect the RELEASE pin of the terminal block to GND To determine the status of the PNP202 examine the STATUS pin The status pin should be a TTL digital level only When the PNP202 is in an up position 5 volts is present whereas 0 volts represents the down position 7 2 HOW TO RELEASE AND REPLACE THE GAS SPRING To replace the spring push up and turn the knob in the center on the bottom of the PNP202 by 90 degrees thereby releasing the gas spring Unscre
9. X Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES Diagram 5 Table Cutout Requirements TABLE TOP SURFACE TOP VIEW TABLE CUTOUT 2 TABLE THICKNESS APPROX 1 0 MIN TO 3 0 MAX ALTINEX r Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 330 ACCESSORIES INSTALLATION 6 Step 1 Step 2 Step 3 Step 4 Make sure the gas spring is not compressed when you remove the locking screw To release the gas spring push down and turn the knob in the center of the bottom of the PNP202 by 90 degrees Remove the lock down screw from the PNP202 The locking screw is the smallest silver colored screw that is located on the bottom of the unit Re engage the gas spring by pushing down on the knob and turning it back to the original position thereby locking the gas spring into place Cut an opening into the table s surface Refer to diagram 5 on page 7 of the manual for table cutout requirements Note The table can be 3 inches or thinner in thickness Always confirm dimensions before cutting to insure that specifications have not changed Place the support plate into the hole in the table The support plate is the square flat plate that can fit into the hole in the table See Figure 1 Figure 1 Support Plate Insert the four screws which are provided into the adjustabl
10. e complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including that which may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications to the unit not expressly approved by Altinex Inc could void the user s authority to operate the equipment EZ VINE T SiGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES ABOUT YOUR PNP202 2 The PNP202 is designed for installation into a conference room table The PNP202 Interconnect Box provides a means of connecting audio video control and computer video sources into
11. e retaining ring from bottom side of the table The adjustable retaining ring allows securing unit to the table The adjustable retaining ring is a flat square plate with two bent edges that will not fit into the hole in the table See Figure 2 Screws Step 5 Step 6 Step 7 Insertion of Screws into Figure 2 Adjustable Retaining Ring Secure the cables by using the provided mounting brackets There two mounting brackets See Figure 3 Pass the power cord from the side of the housing and attach it to the surface with the cable clamp supplied with the PNP202 unit Do not keep the cord too tight or too loose See Diagram 4 page 6 Figure 3 Mounting Brackets Connect the appropriate cables with the correct input connectors There are two RCA connectors on each side of the PNP202 The black connectors are known as audio left whereas the red connectors are called audio right On either side of the unit there is also a RCA video connector which is yellow in color The network connection is red In addition the telephone or data connection is gray Once you have applied power and connected the proper cables on the bottom of the unit you may raise the unit To raise the PNP202 into position press the top of the unit ALTINEX Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com SIGNAL MANAGEMENT
12. figuration Connectors side without fuse box Power Computer Video Composite Video Audio left right 1 IEC standard 15 pin HD F 1 Yellow RCA F 1 Black 1 Red RCA F Audio 1 3 5 mm stereo F Telephone 1 RJ 11 F 6 position Network 1 RJ 45 F 8 position Control 1 DB 9 F Back Panel Standard Configuration Connectors side with fuse box Power Computer Video Composite Video Audio left right 1 IEC with 10 A fuse 1 15 pin HD F 1 Yellow RCA 1 Black 1 Red RCA Audio 1 3 5 mm stereo Telephone 1 RJ 11 Network 1 RJ 45 Control 1 DB 9 F Power 12V 500mA DC Max 10 watts 90 140 VAC 2A Power for Operation Power Consumption Power Rating pass through connector Mechanical Width 6 030in Height opened 7 630in Depth 2 840 Finish Black Operation T Operating 10 35 T Maximum 50 Humidity 90 non condensing ALTINEX SIGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES PNP202 DIMENSIONS 4 Diagrams 1A 1B 1C amp 1D TOP VIEW FRONT VIEW opened PNP2O2 OF PNP202 RCA CONNECTOR AUDIO RIGHT RJ 45 NETWORK RCA CONNECTOR AUDIO LEFT RCA CONNECTOR VIDEO SIGNAL RJ 11 PHONE MODEM JACK COMPUTER AUDIO x _ LABEL 8 SERIAL NUMBER 5mm STEREO 15 PIN CONNECTOR FOR COMP VIDEO
13. les Representative If the product is in your possession for more than 30 days the restocking fees will apply Altinex will not accept any returns on cables or custom products If your product is in warranty and needs service contact the Altinex Sales Department for an RMA Return Material Authorization Products returned without number may experience a delay in service If your product is out of warranty and needs service contact the Altinex Sales Department for an RMA Return Material Authorization Products returned without an number experience a delay in service The service charges will be quoted to you before the actual repairs are done 10 3 CONTACT INFORMATION Sales Department Phone 714 990 2300 Fax 714 990 3303 Accounting Department Phone 714 990 6088 Fax 714 990 5778 ALTINEX SIGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com
14. w the knob and then unscrew the gas spring itself from the PNP202 Replace the gas spring with a new one by screwing it in and then replacing the knob Re engage the new gas spring by pushing up and turning the knob by 90 degrees After you have finished this step you have completed the installation Under normal conditions the gas spring will last up to five years ALTINEX SIGNAL MANAGEMENT SOLUTIONS Tel 714 990 2300 Toll Free 1 800 ALTINEX FAX 714 990 3303 E mail solutions altinex com Web www altinex com ACCESSORIES CABLES AND ACCESSORIES 8 Model No Description CB37xxMR CB39xxMR CB5000PL 5VMxxxVM VGA MALE TO MALE HD 15 HIGH RESOLUTION CABLE xx available length of 3ft 6ft 15ft 25ft 50ft 75ft 100ft 150ft VGA MALE TO FEMALE HD 15 HIGH RESOLUTION CABLE available length of 3ft 6ft 15ft 25ft 50ft 75ft 100ft 150ft 200ft 250ft SUPER HIGH RESOLUTION PLENUM FLEX MULTI CHANNEL COAX CABLE VGA MALE TO VGA MALE HD 15 xxx available length of 3ft 15ft 25ft 5Oft 75ft 100ft 150ft 200ft 250ft SUPER HIGH RESOLUTION PLENUM FLEX MULTI CHANNEL COAX CABLE VGA MALE TO VGA FEMALE HD 15 CB5000PL 5VMxxxVF CB5100PL 5VMxxxVM CB5100PL 5VMxxxVF xxx available length of 3ft 15ft 25ft 50ft 75ft 100ft 150ft 200ft 250ft SUPER HIGH RESOLUTION PLENUM FLEX MULTI CHANNEL COAX CABLE VGA MALE TO VGA FE