Home

X125 - X225 - LM Electronics

image

Contents

1. 4 Connect your speakers to the terminals observing proper polarity 5 Restore power to the amplifier Both channel levels can be adjusted with the corresponding channel level adjustments Dual source connections The X125 and X225 have dual source capability If two sources are used connect the source you want to take temporary priority to the Primary input and the other constant source to the Secondary input Whenever the primary source becomes active that signal will take priority over the distributed audio signal on the secondary line The signal is still active on the secondary line but will not be heard and once the primary audio signal is muted or turned off the amplifier will automatically switch back to the secondary audio signal For dual source connections 1 Connect the source audio outputs to both Primary and Secondary inputs as instructed above 2 Set the switching delay with the Delay Time knob This adjustment determines the length of time it takes to switch back to the secondary signal For example if the primary source is a CD changer increasing the delay time will prevent a switch back to the secondary source while the disc is changing Note This works with all incoming signals line level or speaker level Speaker Level Signal If you have a source that is only available as a speaker level signal connect it to the Speaker Level Input terminals using the spring loaded terminal block and observing proper p
2. and 80 watts into 8 ohms The X225 is rated at 225 watts per channel into 4 ohms and 150 watts into 8 ohms Each amplifier output channel incorporates robust protection circuitry for reliability and safety under extreme circumstances With the Stereo Bridge Mono switch in the Bridge Mono position both amplifier channels are combined for a higher powered mono output In Bridge mode the X125 is rated at 250 watts of power into a single 8 ohm load and the X225 is rated at 470 watts of power into a single 8 ohm load The 12V Trigger In Out allows each amplifier to be activated by other devices or to activate other electronics via a 3 5 mm mini phone plug cable with 100mA current capability Thermal Protection All X Series amplifiers are designed with special circuitry to safeguard the amplifier under a thermal overload condition Thermal protection mode will only engage when the unit has been run at high volume for extended periods of time without adequate ventilation and or when speaker impedances are below the minimum levels for the amplifier In thermal protection mode the amplifier will automatically stop output If this fault occurs turn off the amplifier and check that the speaker impedance rating is above the minimum rating Also check for adequate ventilation around the amplifier and make adjustments if necessary Once the unit has cooled to safe operating temperatures the amplifier may be powered back on Protection Circuitry S
3. washbowl kitchen sink laundry tub in a wet basement or near a swimming pool The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids such as vases shall be placed on the apparatus 6 Carts and Stands The appliance should be used only with a cart or stand that is recommended by the manufacturer An appliance and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the appliance and cart combination to overturn 7 Location of the Amplifier Do not mount this unit under a kitchen cabinet Do not expose the amplifier to direct sun light or heating units as the amplifier internal components temperature may rise and shorten the life of the components Avoid damp and dusty places 8 Ventilation The appliance should be situated so that its location or position does not interfere with its proper ventilation For example the appliance should not be situated on a bed sofa rug or similar surface that may block the ventilation openings or placed in a built in installation such as a bookcase or cabinet that may impede the flow of air through the ventilation openings 9 Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat 10 Power Sources The appliance should be connected to a power supply only of the type d
4. NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE CAUTION TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS Use Class 2 Wiring INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL a Minimum impedance 8 ohms in bridged mode Minimum total impedance AC 120V Master Level Stereo Bridge 12VDC alii AMDA mode Trigger Trigger in Out Speaker B 0 D D A i i Left Left bai Max Min Stereo Bridge 100mA Trigger Normal Mono Auto On RIRussound X Speaker Out ET i Bridge gt i7 Made in China Speaker Level Input Delay Right Left Stereo Bridge 12V Trigger Power Option Speaker Output Power Inlet Voltage Spring Connector Time Channel Switch In Out Switch Fuseholder Selector Controls X125 Rear Panel Russound X125 X225 Installation Manual 5 SYSTEM CONFIGURATION STEREO MODE Stereo Mode Single Source The X125 and X225 can be configured as a power upgrade for specific zones for use with large speaker selectors and for long parallel speaker runs outdoor zones For a single source connection 1 Unplug the amplifier 2 Set the Stereo Bridge switch to Stereo 3 Connect the audio line output from a stereo preamplifier or source to the left and right Secondary input jacks of the amplifier If the output is only available as speaker level see Speaker Level Signal section below
5. x 13 75 D x 5 25 H 41 9 x 34 9 x 13 3 cm 34 2 Ibs 15 4 kg Russound X125 X225 Installation Manual Rev 1 Warranty The Russound X125 and X225 Power Amplifiers are fully guaranteed against all defects in materials and workmanship for two 2 years from the date of purchase During this period Russound will replace any defective parts and correct any defect in workmanship without charge for either parts or labor For this warranty to apply the unit must be installed and used according toits written instructions If service is necessary it must be performed by Russound The unit must be returned to Russound at the owner s expense and with prior written permission Accidental damage and shipping damage are not considered defects nor is damage resulting from abuse or from servicing by an agency or person not specifically authorized in writing by Russound This Warranty does not cover Damage caused by abuse accident misuse negligence or improper installation or operation Power surges and lightning strikes Normal wear and maintenance Products that have been altered or modified Any product whose identifying number decal serial number etc has been altered defaced or removed Russound sells products only through authorized Dealers and Distributors to ensure that customers obtain proper support and service Any Russound product purchased from an unauthorized dealer or other source including retailers mail o
6. RINT ele laren X125 X225 Dual Source Power Amplifiers Installation Manual SAFETY INSTRUCTIONS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN OR ELECTRIC SHOCK DO NOT EXPOSE THIS WARNING TO REDUCE THE RISK OF FIRE A APPLIANCE TO RAIN OR MOISTURE CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance Safety Instructions 1 Read Instructions All the safety and operating instructions should be read before the appliance is operated 2 Retain Instructions The safety and operating instructions should be retained for future reference 3 Heed Warnings All warnings on the appliance in the operating instructions should be adhered to 4 Follow Instructions All operating and user instructions should be followed 5 Water and Moisture The appliance should not be used near water for example near a bathtub
7. d Spea d out CAUTION pav Sent ZZ PEN z DEP CPR CONTE HAS alma 7A iN 8 y Og 00 ov R N 4 ri lo el Tiger Tigger Rom Mont lett Loft e 8 ee se a Q _ zamme D Line Out from Source Configuration with Autoformer Volume Control Rev 1 Russound X125 X225 Installation Manual TECHNICAL SPECIFICATIONS X125 Amplifier Continuous Output Power lt 0 2 THD N Signal to Noise Ratio Crosstalk Frequency Response Input Sensitivity Power Requirements Dimensions Weight X225 Amplifier Continuous Output Power lt 0 2 THD N Signal to Noise Ratio Crosstalk Frequency Response Input Sensitivity Power Requirements Dimensions Weight 10 80W per channel at 8 ohms 125W per channel at 4 ohms 250W bridged mono at 8 ohms gt 93dB A weighted gt 70dB 1 kHz ref to rated power 8 ohms 20Hz to 20kHz 0 0dB 0 5dB 8 ohms 1W 500mV for 80W at 8 ohms 120VAC 60Hz 230VAC 50Hz IEC 320 type connector with 3 terminal detachable power cord 16 5 W x 13 75 D x 3 5 H 41 9 x 34 9 x 8 9 cm 25 6 Ibs 11 52 kg 150W per channel at 8 ohms 225W per channel at 4 ohms 470W bridged mono at 8 ohms gt 93dB A weighted gt 70dB 1 kHz ref to rated power 8 ohms 20Hz to 20kHz 0 0dB 0 5dB amp 8 ohms 1W 500mV for 150W at 8 ohms 120VAC 60Hz 10A 230VAC 50Hz 5 2A IEC 320 type connector with 3 terminal detachable power cord 16 5 W
8. d right channel adjustment on the back panel should be set to the center position to start and then adjusted appropriately from there 1 Unplug the amplifier 2 Set the Stereo Bridge switch to Bridge Mono 3 Connect the line out from a preamplifier or source to the Left and Right Primary input jacks of the amplifier 4 Connect the negative lead of the speaker cable to the R terminal Connect the positive lead of the speaker cable to the L terminal See the markings above the terminals on the rear panel An 8 Ohm minimum load is recommended 5 Restore power to the amplifier 6 Be sure to equally adjust the Master Level right and left X125 Amplifier Negative Conductor 7 Bridge I Fl Mode 7 Right Right Left Left LL TES Bridged Mode Connection Detail Positive Conductor Primary Line Speaker Level Input 8 Secondary bn RaRussound Power Amplifier X125 Litta atta Primary Line Speaker Use Boh Mini don Master Level Stereo Bridge 12VDC Trigger Trigger R L in Out fi 100mA Trigger Normal Auto On Min Max Min Max Stereo CAUTION TO REDUCE TE RISK OF HRE OR ELECTRICAL SHOCK BANOT EMO DIE DA BACK NO USER STABLE PATS y a eee a LIT Right Right Left left AC 230V WARN 3 WARNING ETE IK THE SHOCK j HENT TO RAN OR MOISTURE 8 Ohm Spea
9. escribed in the operating instructions or as marked on the appliance 11 Grounding or Polarization Precaution should be taken so that the grounding or polarization means of an appliance is not defeated 12 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs receptacles and the point where they exit from the appliance Russound X125 X225 Installation Manual 13 Main Power Disconnect The power switch is a single pole switch When the switch is in the Off position the appliance is not completely disconnected from the main power The main power plug is used as the disconnect device and shall remain readily operable When installing the product ensure that the plug is easily accessible 14 Cleaning The appliance should be cleaned only as recommended by the manufacturer 15 Non Use Periods The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time To remove all power supply mains from the appliance remove the plug from the wall outlet 16 Object and Liquid Entry Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through the openings 17 Servicing The user should not attempt to service the appliance beyond that described in the operating instructions All other serv
10. icing should be referred to qualified service personnel 18 Damage Requiring Service The appliance should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen liquid has been spilled into the appliance C The appliance has been exposed to rain or D The appliance does not appear to operate normally or E The appliance has been dropped or the enclosure is damaged LISTED 248808 AUDIO PRODUCTS 1808 Rev 1 TABLE OF CONTENTS Safety INSENUCTIONS 2 esnensensenns emma nine 2 Product Oyervie W amannenn A a O ATETEA E 4 Front and Rear Panels System Configuration Stereo Mode rennes 6 System Diagram Stereo Mode rennes 7 System Configuration Bridged Mode 8 System Configuration External Volume Control 9 T chnical SpeciNcatiQns sn rincara 10 Warranty Rev 1 Russound X125 X225 Installation Manual 3 PRODUCT OVERVIEW Introduction The Russound X125 and X225 are 2 channel dual source power amplifiers with auto source switching Each features Primary and Secondary audio line inputs with a loop out to another zone receiver or device from the secondary source A speaker level input can be connected and assigned as either the primary or secondary source This amplifier can be used for power upgrades in zones for large speaker selector or volume control systems The X125 is rated at 125 watts per channel into 4 ohms
11. itch to Normal and press the Power button on the front panel For automatic power on set the switch to Auto On When music is sensed on any input the amplifier s signal sensing sends a command for it to power on Once the signal ends the amplifier turns off in about 4 minutes To turn the amplifier on remotely set the switch to Trigger and connect a 3 5mm phone plug remote triggering wire from the device to the 12V Trigger In on the amplifier NOTE The front panel Power button must be in the On position for the 12V trigger and Auto On features to work Speaker Cable When connecting speakers to the amplifiers use a minimum 16 gauge and maximum 12 gauge stranded copper cable Avoid leaving stray strands and keep polarity consistent Rev 1 Rev 1 Primary Input RaRussound O Power button FRONT AND REAR PANEL Speakers B O 0 J og A X125 POWER AMPLIFIER Speaker selector Balance control Volume control X125 Front Panel Speaker Level Line Secondary Input Output Input Switch CAUTION Primary Line Speaker Level Input Mn Primary Line No el Secondary Line ia e US Right Ter Left WARNING SHOCK HAZARD DO NOT OPEN Power Amplifier X125 LISTED AVIS RISQUE DE CHOC ELECTRIQUE NES PAS OUVRIR CE CARTER RESERVE AU PERSONNEL AUTORISE F248808 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK PRD Speaker DO
12. ker Line Out from source 120V 60Hz 700W FUSE T6 3AL 250V Made in China 230V 50Hz 700W FUSE T3 15AL 250V Switch set to Bridged Mode Bridged Mode Configuration 8 Russound X125 X225 Installation Manual Rev 1 SYSTEM CONFIGURATION EXTERNAL VOLUME CONTROL System Configuration with External Volume Control The X125 and X225 amplifiers can be configured for large autoformer based volume control systems or speaker selectors Connect up to eight total impedance matching volume controls to the amplifier on speaker A and B outputs e g 8 on A and none on B 4 on A 4 on B etc Each amplifier has a minimum 4 ohm load in stereo mode and minimum 8 ohm load in bridged mode NOTE For more than four volume controls add EZB 2SC Modular Connecting Block expander O O Z NOSNE CE CA Bol Speaker Cable 25 Speaker Cable g 8 Ohm Speaker p 45 g Speaker Cable i E EON Har i KARN eur Speaker Cable Autoformer based Volume Control O O EZB 1SC Modular X225 Amplifier Connecting Block Autoformer based Volume Control Primary Line Speaker Level Input Secondary RARussoun
13. olarity Only one set of speaker level inputs can be utilized and assigned by the selector switch 6 Russound X125 X225 Installation Manual Set the switch to Primary or Secondary This forces the input to act as either the primary or secondary input Only one type of input speaker or line should be assigned to each input When using the Speaker Level Input and it is switched to the Secondary position the high level signal will not pass to the Secondary Line RCA output Rev 1 SYSTEM DIAGRAM STEREO MODE Multiroom Controller secondary source 66 ttizone Controller RIRUSSOUNA werner usa AR KO i rader Speaker Cables X125 Amplifier Secondary HRussound Power Amplifier X125 Os CR 98 Line Out RCA Cable 000000 Rev 1 Speaker Cables CD Player primary source 8 Ohm Speakers Stereo Mode Configuration with Dual Sources CD player is primary source Russound X125 X225 Installation Manual 7 SYSTEM CONFIGURATION BRIDGED MODE Bridged Mode In this mode both the left and right channels are combined for a higher power mono output For proper operation the Master Level left an
14. pecial circuitry has been designed into the amplifier to safeguard under a short circuit condition A faulty speaker can also cause a short circuit condition If this fault condition occurs turn off the amplifier and check speakers for short circuit conditions when appropriate The amplifier power must be cycled for the unit to return to normal operation 4 Russound X125 X225 Installation Manual Installation The amplifiers can be placed on a shelf in an equipment rack or on a table or cabinet Be sure to leave at least 2 inches of space around each side of the amplifier to allow for ventilation and heat dissipation Front Panel Controls On the front panel of the X125 and X225 amplifiers are the power button plus speaker selector balance and volume adjustment Power the front panel switch will manually switch the power on or off Speaker selector select speaker pair main or speaker pair B auxiliary for audio output You can use speakers and B together as long as the speakers are at a minimum 8 ohm impedance Balance adjust speaker output balance between right and left channels The default setting is at center Volume adjust the speaker output volume If using Bridged mode set the volume at minimum then adjust to the desired level Power On Manual Auto Remote The X125 and X225 amplifiers can be turned on manually or automatically by setting a switch on the rear panel For manual power on or off set the sw
15. rder sellers and online sellers will not be honored or serviced under existing Russound warranty policy Any sale of products by an unauthorized source or other manner not authorized by Russound shall void the warranty on the applicable product Damage to or destruction of components due to application of excessive power voids the warranty on those parts In these cases repairs will be made on the basis of the retail value of the parts and labor To return for repairs the unit must be shipped to Russound at the owner s expense along with a note explaining the nature of service required Be sure to pack the unit in a corrugated container with at least three 3 inches of resilient material to protect the unit from damage in transit Rev 1 WARRANTY Before returning a unit for repair call Russound at 603 659 5170 for a Return Authorization number Write this number on the shipping label and ship to Russound ATTN Service 5 Forbes Road Newmarket NH 03857 Due to continual efforts to improve product quality as new technology and techniques become available Russound FMP Inc reserves the right to revise system specifications without notice Russound X125 X225 Installation Manual 11 RINT Cele laren X125 X225 Dual Source Power Amplifiers Installation Manual

Download Pdf Manuals

image

Related Search

Related Contents

L2 LETTRES MODERNES - Université Paris  instrucciones importantes de seguridad instrucciones especiales  Ficha Tecnica SMOOTHING  取扱説明書  MF DIGITAL DIRECTOR EC Installation guide  Manuel d`utilisateur - Sécurité sociale.be  Sony Ericsson DIKAHARE J220i User's Manual  Life Fitness 95Ce Bicycle User Manual  Truly electronic Mftg MP313X User's Manual  