Home
System Board D2109 and SAS Controller D2107
Contents
1. Submitted by Comments on System Board D2109 for TX200 S3 D2109 TX200 S3 N Den ua Da en a Ve un BAAS na e re Eas Det ne nn Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by Comments on System Board D2109 for TX200 S3 D2109 TX200 S3 O FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format Ots fujitsu com The Internet pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at hrrp manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem
2. can be dismantled and the extent to which it can be recycled This saves resources and thus reduces the harm done to the environment Notes on saving energy Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the household waste They must be disposed of in accordance with local regulations concerning special waste All batteries containing pollutants are marked with a symbol a crossed out rubbish bin on wheels In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible since this makes it difficult to recycle them D2109 TX200 S3 Technical Manual 11 Environmental Protection Important notes Returning recycling and disposal The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC con
3. ee 17 3 3 1 ISA bus resources nk a a a a a 19 3 32 PC TESOUESE lt a bc a ae ESE ROR AA 20 3 4 Screen resolution 2 2 2 2 2 mm 21 3 5 Temperature system monitoring 22 3 6 LEDS Sos A eri Ss OS ua 23 E Interfaces and connectors 25 3 7 1 EXISMANDOES 2 a A A AA 26 3 8 Settings with SWICHES 6 o s i s sa rone doa OE 28 4 SAS controller D2107 0 00052 ae 31 5 SCSI IME configuration program 33 6 Replacing the lithium battery 43 Abbrawallons o a esse didas aa ee ke ee eee 45 D2109 TX200 S3 Technical Manual 1 Introduction This technical manual describes the system board D2109 which can be equipped with one or two Intel processors Further information about drivers is provided in the readme files on the hard disk on the supplied ServerStart or Update CDs You will find further information in the BIOS description Notational conventions The meanings of the symbols and fonts used in this manual are as follows italics indicates commands menu items file and path names or software programs fixed font indicate system output on the monitor semi bold fixed indicates values to be entered through the keyboard font Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two ke
4. 24 IO Timeout for Block Devices 0 IO Timeout for Block Devices Removable 0 IO Timeout for Sequential Devices 0 IO Timeout for Other Devices 0 LUNs to Scan for Block Devices A11 LUNs to Scan for Block Devices Removable A11 LUNs to Scan for Sequential Devices A11 LUNs to Scan for Other Devices A11 Removable Media support None Restore Defaults Esc Exit Menu F1 Shift 1 Help Enter Select Item Change Item L J 40 Technical Manual D2109 TX200 S3 SCSI IME configuration program Menu Spinup Properties It is recommended don t change this setting fist Logic MPT Setup Utility Spinup Properties SAS1068 Direct Attached Spinup Delay Secs C 21 Direct Attached Max Targets to Spinup C 01 Expander Spinup Delay Secs E 01 Expander Max Target devices to Spinup C 01 Esc Exit Menu F1 Shift l Help Spinup Delay Defines the intervals for the spinup of the hard disks The default setting is 2 When this feature is enabled the SAS devices which support this function are not started by switching on the server until they receive a Start Unit command from BIOS of the SAS controller This function is used to distribute the high starting currents of the SAS devices over a specific period and to release the power supply of your server D2109 TX200 S3 Technical Manual 41 SCSI IME configuration program Menu P HY Properties It is recommended don t chan
5. BIOS floppy disk from Drive A and reprograms the system BIOS on the board off The System BIOS is started with the system BIOS from the system board default setting Skipping the password query switch 2 Switch 2 is used to define whether the password is queried at system startup if the password protection is enabled in BIOS Setup in Security menu the Password field must be set to Enabled on The password query is skipped Passwords are deleted off The password query is effective default setting 28 Technical Manual D2109 TX200 S3 Features Settings with switches Write protection for Flash BIOS switch 3 Switch 3 is used to define whether the System BIOS is write protected or not on The System BIOS can neither be written to nor deleted Flash BIOS update from floppy disk is not possible off The System BIOS can be written or deleted Flash BIOS update from floppy disk is possible default setting Write protection for floppy disks switch 4 Switch 4 is used to define whether floppy disks can be written or deleted in the floppy disk drive To write and delete floppy disks the write protection in BIOS Setup must be disabled in menu Security the field Diskette Write must be set to Enabled on The floppy disk drive is write protected off Floppy disks can be read written and deleted default setting D2109 TX200 S3 Technical Manual 29 4 SAS controller D2107 If the system board shoul
6. Data Correction SDDC function is supported Module population DJ E DIMM 3B FE Oo DIMM 2B 3 Bm TC I DIMM 1B a HE Du Do DIMM 3A 2 TC Oc DIMM 2A NE a DIMM 1A 2 E Figure 2 Main memory The memory modules have to be based on x4 or x8 organised single or dual ranked FBD533 PC2 4200F or FDB667 PC2 5300 fully buffered DIMM modules and must be populated in pairs It is only allowed you use memory modules released by Fujitsu Siemens Computers Each pair must consist of identical memory modules 2 way interleaved mode The module capacity between pairs can differ pair 1A 1B can be populated with two 512 Mbyte modules and pair 2A 2B with two 1 Gbyte modules 16 Technical Manual D2109 TX200 S3 Features PCI bus Following table shows the mandatory population order module pair 1A 1B module pair 2A 2B module pair 3A 3B black blue blue populated empty empty populated populated empty populated populated populated 3 3 PCI bus slot 5 C PCI 32 33 gt 5 slot 4 PCIe x4 4 slot 3 PCle x3 3 slot 2 PCI X 64 133 OOP u 2 slot 1 PCI X 64 133 IOOP ZCR 1 slot 10 PCI X only SAS controller D2107 10 Figure 3 PCI slots PCI slots The following table shows an overview of the PCI
7. RJ45 LAN ports PCI slots 2 x PCI X 64 bit 100 133 MHz IOOP 1 x PCI Express 2 Gbyte s bandwidth 1 x PCI Express 4 Gbyte s bandwidth 1 x PCI 2 3 32 bit 33 MHz 1 x PCI X only for SAS controller D2107 Technical Manual D2109 TX200 S3 Features Overview BIOS features Phoenix System BIOS V 4 06 Rompilot SMBIOS 2 31 DMI MultiProcessor Specification 1 4 Server Hardware Design Guide 3 0 WfM 2 0 IPMI 1 5 ACPI 2 0 support USB keyboard mouse boot possible from 120 MB floppy disk drive CD ROM DVD Festplatte LAN console redirection support OEM logo CPU memory disable hotspare memory support Environmental protection battery in holder Form factor 302 x 415 mm D2109 TX200 S3 Technical Manual 15 Main memory Features 3 2 Main memory The system board supports up to 16 Gbyte main memory 6 slots 3 memory banks with 2 modules are available for the main memory Each memory bank can be populated with two 512 Mbyte 1 Gbyte 2 Gbyte or 4 Gbyte FBD533 PC2 4200F or FDB667 PC2 5300F fully buffered DIMM memory modules A memory bank can be configured as hot spare bank optional As in the basic configuration memory bank 1 is populated with 1 Gbyte 2 Gbyte 4 Gbyte or 8 Gbyte memory modules the memory extensions can be performed up to two times for memory bank 2 and 3 ECC with memory scrubbing and with the Single Device
8. Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interfache OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device PS U Power Supply Unit D2109 TX200 S3 Technical Manual 47 Abbreviations PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array if Inexpensive Disks RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interfache SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide SMB System Management Bus SMM Server Management Mode 48 Technical Manual D2109 TX200 S3 Abbreviations SMP Symmetrically Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN D2109 TX200 S3 Technical Manual 49 N Den ua Da en a Ve un BAAS na e re Eas Det ne nn Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections
9. board observe the specific instructions described in the service manual for the server Remove the plug from the mains outlet so that system and system board are totally disconnected from the mains voltage To prevent damage to the system board the components and conductors on it please take great care when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screwdrivers for leverage 2 2 CE Certificate The shipped version of this board complies with the requirements C of the EEC directive 89 336 EEC Electromagnetic compatibility Compliance was tested in a typical PRIMERGY configuration 10 Technical Manual D2109 TX200 S3 Important notes Environmental Protection 2 3 Environmental Protection Environmentally friendly product design and development This product has been designed in accordance with standards for environmen tally friendly product design and development This means that the designers have taken into account important criteria such as durability selection of materials and coding emissions packaging the ease with which the product
10. slots PCI slot 64bit Frequency Description 32bit in MHz 1 64 bit 100 133 64 bit PCI X slots 133 MHz only if one of the 2 64 bit 100 133 three slots 1 2 or 10 is populated D2109 TX200 S3 Technical Manual 17 PCI bus Features PCI slot 64bit Frequency Description 32bit in MHz 3 PCl e x8 slot 4 PCl e x4 slot 32 bit 33 32 bit PCI slot 10 64 bit 100 133 PCI X slot only for SAS controller D1207 IOOP PCI bus speed optimisation The hardware of the system board optimizes the PCI bus speed of the slots 1 2 and 10 depending on the slots population the PCI bus speed is 133 MHz if only one of the three slots or no slot is populated the PCI bus speed is 100 MHz for all other population variants for slot 1 2 and 10 Zero Channel RAID with SAS controller D2107 PCI slot 1 blue sockel is prepared for Zero Channel RAID ZCR ZCR means that the SCSI controller is seen as SCSI RAID controller through the inserted SAS controller D2107 The PCI bus then runs with 100 MHz Technical Manual D2109 TX200 S3 Features PCI bus 3 3 1 ISA bus resources Device IRQ Address DMA Timer 0 040 043 Keyboard 1 060 064 Serial port COM2 3 3F8 3FF 2F8 2FF 3E8 3EF 2E8 2EF Serial port COM1 4 3F8 3FF 2FB 2FF 3E8 3EF 2E8 2EF free 5 Floppy disk drive controller
11. the depending entry and press the ENTER key to change into the submenus Detailed instruction on the configuration and on the submenus are contained in the manual Integrated RAID for SAS User s Guide 34 Technical Manual D2109 TX200 S3 SCSI IME configuration program Menu Adapter Properties f LSI Logic MPT Setup Utility Adapter Properties SAS1068 Adapter Properties SAS1068 PCI Slot 00 PCI Address Bus dev Func 02 08 00 MPT Firmware Revision 1 10 01 00 IR SAS Address 5003005F FFFFFFFO Status Enabled Boot Order 0 Boot Support Enabled BIOS amp OS J RAID Properties SAS Topology Advanced Adapter Properties Esc Exit Menu F1 Shift 1 Help Enter Select Item Change Item L Boot Support Enabled BIOS amp OS it is recommended don t change this setting or Enabled BIOS only Menu RAID Properties see page 386 Menu SAS Topology see page 38 Menu Advanced Adapter Properties see page 39 D2109 TX200 S3 Technical Manual 35 SCSI IME configuration program Menu RAID Properties In this menu you can start the RAID configuration menu fist Logic MPT Setup Utility Select New Array Type SAS1068 View Existing Array View Create IM Volume Crea Create IME Volume Crea ALL Create IS Volume Crea 2 to ALL Array of 3 to 8d optional hot spare the existing te Integrated disks plus an optional hot spare Data on the pri
12. to the PCI interrupt 3 4 5 6 7 9 10 11 12 14 15 The selected ISA interrupt is assigned to the PCI interrupt You may not select an ISA interrupt that is used by a component on the system board e g controller or an ISA board 20 Technical Manual D2109 TX200 S3 Features Screen resolution A B c D Slot 1 PCI IRQ line 4 PCI IRQ line 3 PCI IRQ line 2 PCI IRQ line 1 Slot 2 PCI IRQ line 3 PCI IRQ line 4 PCI IRQ line 1 PCI IRQ line 2 Slot 3 PCI IRQ line 1 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 Slot 4 PCI IRQ line 1 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 Slot 5 PCI IRQ line 1 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 Slot 10 PCI IRQ line 2 PCI IRQ line 3 PCI IRQ line 4 PCI IRQ line 1 VGA PCI IRQ line 6 LAN PCI IRQ line 3 7 USB PCI IRQ line 8 PCI IRQ line 7 PCI IRQ line 6 PCI IRQ line 5 A D Interrupt output of the PCI controller Interrupts of LAN channel 1 respective 2 3 4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the screen controller on the system board If you are using an external screen controller you will find details of supported screen resolutions in the operating manual or technical manual supplied with the controller Screen resolution Supported colours 640x480 8 bit 16 bit 24 bit 800x6
13. 00 16 bit 24 bit 1024x768 16 bit 1152x864 8 bit 1280x1024 8 bit D2109 TX200 3 Technical Manual 21 Temperature system monitoring Features 3 5 Temperature system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The following functions are supported Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature sensor measurement of the ambient temperature by a 12C temperature sensor Fan monitoring The CPU power supply unit and system fans are monitored Fans that are no longer available blocked or sticky fans are detected Fan control The fans are regulated according to temperature Sensor monitoring The removal of or a fault in a temperature sensor is detected Should this happen all fans monitored by this sensor run at maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated Cover monitoring Unauthorised opening of the cover is detected even when the system is switched off However this will only be indicated when the system is switched on again 22 Technical Manual D2109
14. 17 USB8 5 PC98 18 USB 7 6 Power supply PWR2 19 RAID key SATA SW RAID 7 Power supply PWR1 20 HD LED 8 USB 1 2 21 SATA MLC1 9 IDE primary 22 SATA MLC2 10 Floppy disk drive 23 KVM power 11 Front panel 24 IPMB 12 System fan 1 25 PCI slots 13 CPU 1 2 fans 26 External ports D2109 TX200 S3 Technical Manual 25 Interfaces and connectors Features 3 7 1 External ports 20000 0 0 0 0 0 Figure 6 External ports of the system board D2109 1 PS 2 mouse connector 6 2 serial interface COM2 7 serial interface COM1 3 USB ports 3 and 4 8 PS 2 keyboard connector 4 LAN connector 2 9 IDLED 5 LAN connector 1 service LAN 10 Global Error LED VGA port The serial interface COM1 can be used as default interface or to communicate with the iRMC LAN connectors On this system board you will find two LAN controllers a single channel Gigabit LAN controller and a service LAN controller The single channel Gigabit LAN controller supports the transfer rates of 10 Mbit s 100 Mbit s and 1 Gbit s The Service LAN controller supports the transfer rates of 10 Mbit s and 100 Mbit s The LAN controllers support WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here Intel PXE is supported
15. 6 3F0 3F5 3F7 2 Parallel interface LPT1 7 278 27B 378 37B 3BC 1 3 3BF Real time clock RTC 8 070 071 free 9 10 11 Mouse controller 12 Numeric processor 13 OFO OFE IDE controller primary 14 1F0 1F7 3F6 IRQ interrupt assigned as shipped Address this address can be used for your particular device Address this DMA can be used for your particular device Default settings are shown in bold print D2109 TX200 S3 Technical Manual 19 PCI bus Features 3 3 2 PCI resources PCI IRQ Line x Assignment of the PCI interrupts PCI IRQ Line x defines which ISA interrupts are used for the separate PCI slots If you select Auto in the BIOS setup the interrupts are assigned automatically and no further settings are required Multifunctional PCI boards or boards with an integrated PCI to PCI bridge can use several PCI interrupts INTA INTB INTC INTD Monofunctional PCI boards default only use one PCI interrupt INTA per PCI slot The PCI interrupts INTA INTB INTC and INTD are available for each PCI slot The same interrupt can be assigned simultaneously to several PCI boards You should avoid this condition due to reduced performance If you use a setting other than Auto the Plug amp Play functionality of the system BIOS for the corresponding PCI boards is deactivated Auto The PCI interrupts are assigned automatically in accordance with the Plug amp Play guidelines Disabled No ISA interrupt is assigned
16. Manual 43 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations Not all technical terms and abbreviations listed here are valid for the described system board ACPI Advanced Configuration and Power management Interface ASSR Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit DDR Double Data Rate DIMM Dual In line Memory Module D2109 TX200 S3 Technical Manual 45 Abbreviations DIP Dual In line Package DMI Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD HPC Hotplug Controller ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IME Integrated Mirror Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus 46 Technical Manual D2109 TX200 S3 Abbreviations IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller LAN Local Area Network LED Light Emitting Diode MPS Multi Processor
17. System Board D2109 and SAS Controller D2107 for TX200 S3 Technical Manual Edition June 2006 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Fax forms for sending us your comments are included in the back of the manual There you will also find the addresses of the relevant User Documentation Department Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Contents 1 Introduchon ax a 2 iad eave RR a 5 2 important notes oce 2 pede rare 5 4a na SSS 7 2 1 Notes on Sale o 2 0 e GR een a a E 2 2 CE DEDICA soh AA amp Bw a 10 2 3 Environmental Protection 2 2 2 22mm 11 3 FEAS lt a a a a a 13 3 1 o ne ae ly Br are 13 3 2 BI IO kad a he eS Bata ek bk ee we 16 3 3 POLDUS Semi EEE A ie de A oe
18. TX200 S3 Features LEDs System Event Log SEL All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log They could be retrieved in the BIOS Setup or via ServerView PRIMERGY Diagnostic LEDs Optical signaling through the LEDs on the systemboard identifies defective modules and components as well as gaining information on the PDA 3 6 LEDs L1L2 L3 L6 Super 1 0 N CPU 1 L7 RMC CPU 2 om zZ 18 O gt EE a O of Figure 4 LEDs L1 and L2 are visible from outside on the rear of the server All the other LEDs are only visible if the cover of the server is open D2109 TX200 S3 Technical Manual 23 LEDs Features The LEDs have the following meaning LED Indicator Meaning L1 Status Global Error orange indicates a prefailure orange flashing indicates a failure Reasons for a failure may be overheating of one of the sensors sensor defe
19. The LAN1 port serves as management interface and is prepared for RemoteView 26 Technical Manual D2109 TX200 S3 Features Interfaces and connectors The LAN connectors are equipped each with two LEDs light emitting diode indicating the transfer rate and the activity Figure 7 LAN connector single channel Gigabit LAN controller 1 LAN transfer rate green off transfer rate 10 Mbit s yellow green on transfer rate 100 Mbit s yellow jon transfer rate 1000 Mbit s 2 LAN link aktivity green on LAN connection off no LAN connection flashing LAN transfer Figure 8 LAN connector service LAN controller 1 LAN transfer rate green off transfer rate 10 Mbit s green on transfer rate 100 Mbit s 2 LAN link aktivity green on LAN connection off no LAN connection flashing LAN transfer D2109 TX200 S3 Technical Manual 27 Settings with switches Features 3 8 Settings with switches ON Eee 12 3 4 Figure 9 DIP switch i Preset for switches 1 to 4 Off Recovering System BIOS switch 1 Switch 1 enables recovery of the old system BIOS after an attempt to update has failed To restore the old system BIOS you need a Flash BIOS Diskette please call our customer service centre on The system boots from the Flash
20. Utility SAS Topology SAS1068 Device Identifier Device SAS1068 02 08 00 Info I_ Enclosure Direct Attach Devices Controller _ Bay 0 SEAGATE ST3146854SS 1501 SAS _ Bay 1 SEAGATE ST336754SS 1501 SAS _ Bay 2 SEAGATE ST336754SS 1501 SAS _ Bay 4 RAID Physical Disk SAS _ Bay 5 RAID Physical Disk SAS I_ IM VOL LSTLOGICLogical Volume 3000 SEAGATE ST373454SS 1501 gt SEAGATE ST3146854SS 1501 Esc Exit Fl Help Alt D Device Properties Alt M More Keys k J 38 Technical Manual D2109 TX200 S3 SCSI IME configuration program Menu Advanced Adapter Properties f LSI Logic MPT Setup Utility Advanced Adapter Properties SAS1068 IRQ OB NUM Yes IO Port Address 3000 Chip Revision ID 01 CHS Mapping SCSI Plug and Play Mappingl Advanced Device Properties Spinup Properties P R HY Properties estore Defaults Esc Exit Menu F1 Shift l Help Enter Select Item Change Item L CHS Mapping SCSI Plug and Play Mapping it is recommended don t change this setting or Alternate CHS Mapping Menu Advanced Device Properties see page 40 Menu Spinup Properties see page 41 Menu PHY Properties see page 42 D2109 TX200 S3 Technical Manual 39 SCSI IME configuration program Menu Advanced Device Properties It is recommended don t change this setting Fis Logic MPT Setup Utility Advanced Device Properties SAS1068 Maximum INT 13 devices for this adapter
21. call the previous menu and to terminate the SAS configu ration program F2 to jump into the menu line This function is not available in all menus Calling the SAS IME configuration program Start the PC if the following message appears press the key combination CTRL and C Press Ctrl C to start LSI Logic Configuration Utility Following hint appears next Please wait invoking LSI Logic Configuration Utility D2109 TX200 S3 Technical Manual 33 SCSI IME configuration program In the first menu all available SAS controllers are displayed LSI Logic MPT Setup Utility Adapter List Global Properties Adapter PCI PCI PCI PCI FW Revision Status Boot Bus Dev FNC Slot Order SAS1068 02 08 00 00 1 10 01 00 IR Enabled 0 Esc Exit Menu F1 Shift l Help Alt M Global Properties Alter Boot Order Ins Del Alter Boot List R J Terminating the SAS IME configuration program Depending on the current menu level you can display the previous menu by pressing the ESC key If you have made changes in the current menu you will be prompted to store them gt To quit the configuration program press the ESC key until a corresponding message is displayed Configuring IME gt To set the SAS IME properties of the SAS controller select your adapter in the menu by using the arrow keys Press the ENTER key to change into the menu Adapter Properties gt From there select
22. cerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU To return your used device please use the return and collection systems available to you You will find further information on this at www fujitsu siemens com recycling For details on returning and reuse of devices and consumables within Europe refer to the Returning used devices manual or contact your Fujitsu Siemens Computers branch office subsidiary or our recycling centre in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 12 Technical Manual D2109 TX200 S3 3 Features 3 1 Overview Processors 1or2x Intel Xeon dual core processors 2 processor sockets LGA771 for Intel Xeon processor 2x2 or 4 MB second level cache on die unified 64 byte cache line size 24 KB L1 cache on die data 16 KB L1 cache on die instruction 2x VRM 11 0 onboard EVRD Main memory 6 slots for main memory FBD533 PC2 4200F or FDB533 PC2 5300F Fully Buffered DIMM memory modules with 512 MB 1 Gbyte 2 Gbyte and 4 Gbyte maximum 16 Gbyte of memory minimum 1 Gbyte 2 memory modules maximum 16 Gbyte s bandwidth supports 2 way interleaved memory subsystems 2 identical memory modules have to i
23. ct fan defect CPU error Software detected an error L2 ID blue server is identified via ServerView L3 board orange aux voltage available L4 board green system running L5 board red configuration error The system board will be held in reset Possible configuration errors are e g old CPU populated CPUs with different FSB requirements populated CPU1 not populated L6 board green flashing iRMC server management controller is ok off RMC not alive L7 system green fan running fan 1 off fan failure L8 system green fan running fan 2 off fan failure 24 Technical Manual D2109 TX200 S3 Features Interfaces and connectors 3 7 Interfaces and connectors 67 hi o go 410 26 I CPU 1 11 RMC CPU 2 mi 12 OBeeper Il t 1 5 2423 22 21 2019 18 1716 Figure 5 Schematic view of the system board D2109 1 Printer optional 14 Redundant system fan 2 DIP switch see page 28 15 System fan 2 3 Power supply PWR3 16 Intrusion 4 Slots for main memory modules
24. d support fully SAS functionality the SAS controller D2109 has to be installed in PCI slot 10 1 2 O Of O A g o v Ps g gt wn Q 5 Figure 10 Schematic view of the SAS controller D2107 1 SAS connector MLC2 2 SAS connector MLC1 D2109 TX200 S3 Technical Manual 31 5 SCSI IME configuration program The SAS controller D2107 is equipped with an eight channel SAS controller 1068 from LSI Logic You will find the exact location of the SAS connectors in the schematic view of the SAS controller D2107 The BIOS of the SAS controller includes a menu driven SAS IME Integrated Mirror Enhanced configuration program This program allows you to change almost all of the option settings of the SAS controller When you boot the system a SAS BIOS message listing the SAS devices connected is displayed If a SAS BIOS error message appears or problems arise with SAS devices please read the documentation of your SAS device If you are unable to trace or rectify the error please contact your dealer or our customer service centre Working with the keyboard Use the following keys when running the program arrow keys to make selections E E to change a selection ENTER to accept a selection ESC to
25. den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und unter http manuals ts fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
26. ge this setting Device Identifier Scan Order Device Information SAS Address isi Logic MPT Setup Utility PHY Properties SAS1068 PHY 0 1st of 8 PHYs SAS Port 0 Link Status Enabled 3 0 Gbps Discovery Status 000000 SEAGATE ST3146854SS 1501 0 SAS 5000C500 0000EB39 Esc E Enter k xit Menu F1 Shift 1 Reset Phy error logs Help Alt N Next Phy Alt P Previous Phy 42 Technical Manual D2109 TX200 3 6 Replacing the lithium battery In order to save the system information permanently a lithium battery is installed to provide the CMOS memory with a current When the charge is too low or the battery is empty a corresponding error message is provided The lithium battery must then be replaced The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top at Figure 11 Replacing the lithium battery gt Press the locking spring into direction of of the arrow 1 so that the lithium battery jumps out of its socket gt Remove the battery 2 gt Insert a new lithium battery of the same type into the socket 3 and 4 D2109 TX200 S3 Technical
27. ion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer It is essential to observe the instructions in chapter Replacing the lithium battery Technical Manual D2109 TX200 S3 Important notes Notes on safety Modules with electrostatic sensitive components Systems and components that might be damaged by electrostatic discharge ESD are marked with the following label A AteS When you handle components fitted with ESDs you must observe the following points under all circumstances Figure 1 ESD label e You must always discharge yourself of static charges e g by touching a grounded object before working e The equipment and tools you use must be free of static charges e Remove the power plug from the power socket before inserting or removing boards containing ESDs e Always hold boards with ESDs by their edges e Never touch pins or conductors on boards fitted with ESDs e Use a grounding cable designed for this purpose to connect yourself to the system unit as you install deinstall the board e Place all components on a static safe base You will find a detailed description for handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD 20 20 D2109 TX200 S3 Technical Manual 9 CE Certificate Important notes Notes about boards During installation deinstallation of the system
28. l result in the invalidation of the warranty and exclusion from all liability e Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts e Only install expansions that are allowed for the system board If you install other expansions you may damage the requirements and rules governing safety and electromagnetic compatibility or your system Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet e The warranty expires ifthe device is damaged during the installation or replacement of system expansions D2109 TX200 S3 Technical Manual 7 Notes on safety Important notes N Batteries Components can become very hot during operation Ensure you do not touch components when making extensions to the system board There is a danger of burns Transmisson lines to peripheral devices must be adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard CAUTION Incorrect replacement of lithium battery may lead to a risk of explos
29. mary di te Integrated DATA on array te Integrated 8 disks DATA on array configuration Mirror Array of 2 sk may be migrated Mirrored Enhanced isks including an disks will be DELETED array of disks will be DELETED Esc Exit Menu F1 Shift l k Help Enter Choose array type to create Esc Return to Adapter Properties 36 Technical Manual D2109 TX200 S3 SCSI IME configuration program Menu View Existing Array View Array displays the status of the configured hard disks fist Logic MPT Setup Utility View Array SAS1068 Array tof 1 Identifier LSILOGICLogical Volume 3000 Type IM Scan Order 4 Size MB 34332 Status Optimal Manage Array Esc Ex i Enter Select Item Alt N Next Array C Create an array Slot Device Identifier RAID Hot Drive Pred Size Num Disk Spr Status Fail MB 4 SEAGATE ST373454SS 1501 Yes No Primary No 34332 5 SEAGATE ST3146854SS 1501 Yes No Secondary No 34332 t Menu F1 Shift 1 Help Only two RAIDs can be configured on the SAS Controller 1068 The administration of the RAID system can be set later by a tool in your operating system see therefore the documentation Global Array Manager D2109 TX200 S3 Technical Manual 37 SCSI IME configuration program Menu SAS Topology SAS Topology displays the allocations of the hard disks f LSI Logic MPT Setup
30. nstalled at the same time ECC multiple bit error detection and single bit error correction memory scrubbing function Single Device Data Correction SDDC function Chipkill Hot spare memory support Chips on the system board Intel BlackfordVS Chipset Single channel Gigabit LAN controller PHY Intel 82564EB Mono Gilgal Service LAN controller 10 100 PHY Broadcom AC201KMLG Integrated VGA controller with PCI 32 Bit 33 MHz Super I O controller SMSC DME1737 Flash EPROM for SCSI BIOS BIOS LAN server management SM server management with RMC FSC System D2109 TX200 S3 Technical Manual 13 Overview Features thermal and system management controller ADT7462 Internal connectors floppy disk connector 34 pin 1 IDE primary 2 Serial ATA SCSI activity connector HD LED main power connector 12V 12V 5V 3 3V and 5V auxiliary 1 dual 12V power connector 1 mono 12V power connector PC98 connector front panel dual USB type for USB port on front side 2 USB connectors 2 connectors for system fans 1 connector for CPU fans IPMB connector RSB data KVM power connector intrusion connector 1 RAID key 1 connector for 2 additonal redundant system fans optional External connectors 2 serial ports COM1 COM2 1 parallel port optional 2 PS 2 interfaces for keyboard and mouse 2 USB 2 0 ports with 480 Mbits s rear side 1 VGA port 2
31. ys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols quotation marks indicates names and terms that are being empha sized indicates an operation that to be performed gt CAUTION indicates warnings which if ignored will endanger your health destroy the system or lead to the loss of data Li indicates additional information notes and tips Table 1 Notational conventions D2109 TX200 S3 Technical Manual 2 Important notes In this chapter you will find essential information regarding safety when working with your server CAUTION With the system board installed you must open the system to access the system board How to access the system board of your system is described in the appropriate service supplement When handling the system board refer to the specific notes on safety in the operating manual and or service supplement for the respective server 2 1 Notes on safety CAUTION e The actions described in these instructions should only be performed by authorized qualified personnel Equipment repairs should only be performed by qualified staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device wil