1. ES Display Prestige Excellence Prestige Solo IT DE EN Scheda display Display Pressure gauage 0 4 bars FR Manometre 0 4 bars Prestige AquaSpeed NL Manometer 0 4 bar ES Man metro O 4 bares Prestige Excellence Prestige Solo IT Manometro O 4 bar DE EN Manometer O 4 bar ON OFF switch FR Interrupteur general Prestige AquaSpeed NL ES Hoofdschakelaar Interruptor general Prestige Excellence Prestige Solo IT Interruttore generale DE EN An Aus Schalter Air inlet tube to venturi FR Tube dentree d air venturi Prestige AquaSpeed NL Inlaatbuis venturi ES Tubo de entrada de aire venturi Prestige Excellence IT Tubo d ingresso dell aria nel venturi DE Eintrittrohr Venturi 557D3011 55426017 55445006 55445007 55426001 Prestige Solo Water pressure safety Switch Pressostat de s curit mangue d eau Prestige AguaSpeed Waterdruk schakelaar Presostato falta de agua Prestige Excellence Prestige Solo Pressostato di sicurezza mancanza d acqua Wassermangelsicherung Safety valve 3 bars Y 1 2 Y 3 4 Soupape de s curit 3 bars Y 1 2 Y 3 4 Prestige AquaSpeed Veiligheidsventil 3 bar O 1 2 Y 3 4 V lvula de seguridad 3 bare
2. m BEYEN AV MPK ZU AUF pg erjuwjojejejz o so v eja v ZMC1 0 Du A B VF VE SSISSISS mmm OD mm Paie 1 Bet we le mm 3 mmm 3 um ll O D E D D E D Factory typical setting Description 0 0 ct ct J 0 OO Heating mode OFF 01 Heating mode ON Hu EO c3 si Setting T for the heating water adjustable between 30 and 85 C ek Mu E 8 t ES HY oo eo un T min for the heating water adjustable between 15 and 60 C EO Ly C3 E un 8 e EO Lu Ea M Hydraulic parameter 6 23 EN 21 ELECTRICAL CONNECTION 4InOJIO OMI N sduund U017994407 InOJIO JO ON 0497 jpguordo y ou guondo g ou jeuomd0 3InOJIO aya YO 40su8s ONIN aun3eJadula7 JOOPINO GOIN jeuo17d0 geIsoWwusyI WOOY aungeJadulaz sef any GOIN JOY JHS9UJOD BEGIN Josuas uunjaJ 291N Le Oc 6L BL Lb 9L GL EL al Josues MOL LOIN LL UMS aunssaud Jaen OL Uaa49G G u88Jc MO 9A VAIN 8 HUA J8U4J0JSUEJ1 JOAGE HOADES 4 16101 gAIBA seg 9 pay JauJng G 85ugJ dund BuneaH py haan 783005 duund BuiBueuo xue3 Jaen E UMOJg yay ms dois Jupe o 22814 p409 U0l128UU0N AOL L anjg J9 M A d 10 Jg id H EE J A a29U43 199x3 peedsenby ojos z Vz 39
3. Gas connection 3 4 M DISTANCES OF HYDRAULIC CONNECTIONS EXCELLENCE CH supply 1 F CH return 1 F Domestic hot water supply 3 4 M Cold water inlet 3 4 M Gas connection 3 4 M A B E 61 ra C D 206 T EN e 11 INSTALLATION CONNECTION TO THE CHIMNEY Table of flue resistance in Pascal The chimney connections must comply with the applicable 1Pascal 0 01 mbar standards in Belgium NBN D51 003 the local energy supplier s instructions the fire regulation and neighbourhood good practices Pipe Air inlet Air extraction concentric separate separate The Prestige has an inbuilt gas air ratio regulator which makes 80 125 80 80 it largely independent of the pressure drop in the air intake and mm mm mm flue gas extraction system However the maximum pressure drop for this system may not be exceeded or the pressure will 1 m straight pipe 5 0 1 5 2 0 diminish Nevertheless the gas air ratio regulator continuously guarantees optimum combustion with very low emission levels GH a monitoring 2 5 _ 1 0 section The horizontal flue gas pipes must always be installed with a min slope of 5 mm per meter upwards from the boiler side 20 pipe bend CH e GR There must be no obstruction or openings for any other appl
4. 12 kQ DHW NTC sensor 12 kQ Sonde NTC sanitaire 12 kQ Prestige AquaSpeed NTC voeler sanitair 12 kQ Sonda NTC sanitaria 12 kQ Prestige Excellence Prestige Solo Sonda NTC sanitaria 12 kQ NTC Brauchwasserfuhler 12 kQ lonisation and ignition cable Cable d ionisation et d allumage Prestige AquaSpeed Ontsteek ionisatie kabel Cable de ionizacion y encendido Prestige Excellence Prestige Solo Cavo di accensione e d ionizzazione lonisations und Z ndungskabel Rectifier 24 Volt C ble rectificateur 24 Volt Prestige AquaSpeed Gelijkrichter 24 Volt Cable rectificador 24 Volt Prestige Excellence Prestige Solo Cavo rettificatore 24 volt Gleichrichter 24 Volt Flat cable C ble plat Prestige AquaSpeed Kabel display Cable plano Prestige Excellence Cavo piatto Kabel display 547D3021 537D3020 54763010 54766016 t 497B0025 Prestige Solo EN FR Transformer 230 Volt 24 Volt Transformateur 230 Volt 24 Volt Prestige AguaSpeed NL Transformator 230 Volt 24 Voltl ES Transformador 230 Volt 24 Volt Prestige Excellence Prestige Solo IT Trasformatore 230 Volt 24 Volt DE EN Transformator 230 Volt 24 Volt Display board FR Platine display Prestige AquaSpeed NL Display
5. 21474419 A02 21473419 21471419 A05 54761008 A09 2147E419 21476419 Prestige Excellence 21475420 A01 21471420 21480069 21474420 A02 21473420 A01 21471420 A07 497B6002 A05 54761008 A11 2247F420 A08 497B6003 A09 2147E420 i i 3 A10 21476420 ss N EN FR NL ES IT DE B01 Flue gas pipe Tube de fum es Rookgas pijp Tubo de humos Condotto fumi Abgasrohr 80mm 80mm 80mm 80mm 80 mm 80mm B02 Heat Echangeur aL Intercambiador Scambiatore feet exchanger de chaleur de calor di calore Exchanger Tube de d part Aanvoerleiding 14180 de sanca ER Tubo d mandata Vorlaufrohr B03 S intercambiador M flow pipe de l changeur warmtewisselaar er da lo scambiatore W rmetauscher Heating Circulateur Verwarming Circulador Circolatore AP Heizungspumpe B04 circulator chauffage circulator de calefacci n riscaldamento 1 L130 mm 1 L 130 mm 1 L 130 mm 1 L 130 mm 1 L 130 mm 1 L 130 mm Heating circulator Tube d part du IE ie g ide Do al el Vorlaufrohr B05 i Verwarming del circulador da lo circolatore flow pipe circulateur chauffage i S Ss Heizungspumpe circulator pijp de calefacci n riscaldamento B06 Condenstrap Siphon 5 4 Syfon 5 4 Sifon 5 4 Sifone 5 4 Siphon 5 4 5 4 L 300 mm L 300 mm L 300 mm L 300 mm L 300 mm L 300 mm B07 Gas pipe Tube ga
6. Ed 08 u Coude 90 Bocht 90 Codo 90 Curva 90 ES 09 Condensate H cup rateur Condensopvang Recuperador Recuperatore RE AE GIE recovery de condensats de condensados di condensati 10 Messung Tube de mesure Meetelement Tubo de medida El mene Messelement element di misura Parallel Adaptateur de Adaptador de Adattatore di Parallel M Paralleler 11 connection raccordement Ss conexi n collegamento i aansluitingsadapter e Verbindungsadapter adapter en parallele paralelo in parallelo e Te adaptador 12 AUS Be Solin r glable ege Dare para chimenea Tegola regolabile Bleidachpfanne flashing losse pan desdodlada 13 de is si Solin toit plat SE pan eu deer S Flachdachflansch flashing plat dak chimenea tetto piatta Bracket Ace ER Bevestigind Brida fijaci n 2 uin Befestigung 14 fixation di fissazione 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm 01 537D6185 02 537D6184 03 537D6186 04 537D6187 05 537D6188 10 537D6193 06 537D6189 a 11 537D6232 E 07 537D6190 12 537D6195 537D6194 08 537D6191 09 537D6192 14 537D6183 al 5476G008 547D3018 257F1071 537D3039 257F1079 Prestige Solo NTC sensor 5 x 18 12 KQ Sonde NTC 5 x 18 12 kQ Prestige AquaSpeed NTC voeler 5 x 18 12 kQ Sonda NTC 5 x 18 12 kO Prestige Excellence Prestige Solo Sonda NTC 5 x 18 12 kO NTC F hler 5 x 18
7. Heat exchanger stainless steel Pump central heating Pump Domestic Hot Water Electrical panel The control boxes on the rear are optional Flue tube Control panel Burner premix and modulating Flue tube concentric tubes 80 125 mm Manual air vent Water heater 62 litres 8 A Pump Domestic Hot Water ON ON AC ES Pump central heating Heat exchanger stainless steel n Hot water storage tank stainless steel Electrical panel The control boxes on the rear are optional Drywell for DHW sensor Expansion vessel depend of countries Control panel Bracket for expansion vessel USERS DIRECTIONS FOR USE Your system must be checked once a year by an approved installer or maintenance company Starting the burner During operation the burner starts automatically as soon as the boiler temperature drops under the required set point and It stops as soon as the boiler reaches that temperature Control panel Pressure gauge Start Stop switch Heating system The central heating circuit must be pressurized see in the chapter Installation how to define the system pressure The pressure indicator is located on the right hand side of the display A If your system needs to be refilled more than twice a year please contact your installer The CH pressure must
8. Gas pressure mbar 30 37 50 G31 gas flow rate m3 h 0 98 1 3 0 98 13 0 98 dis CO max Input G31 with front panel closed CO 11 11 11 11 11 11 CO max Input G31 with front panel open CO 10 7 10 7 10 7 10 7 10 7 10 7 CO max Input G31 with front panel closed CO 10 9 10 9 10 9 10 9 10 9 10 9 Hydraulic parameters Max operating temperature C 90 90 90 90 90 90 Boiler water capacity L 8 8 14 14 16 16 Domestic hot water circuit capacity L 0 9 0 9 54 54 Maximum operating pressure central heating bar 3 3 3 3 3 3 Heat exchanger pressure drop AT 20 C mbar 131 210 131 210 131 210 Capacity of the expansion vessel depend of countries L 12 12 Electrical connection Class IP 30 30 30 30 30 30 Supply voltage V Hz 230 50 230 50 230 50 230 50 230 50 230 50 Maximum absorbed electrical power A 0 8 0 8 1 2 1 2 1 2 1 2 Weight empty kg 48 48 63 63 92 92 TECHNICAL CHARACTERISTICS AT CH CZ DK ES IT FI Natural gas categories BE FR NL LU DE UK IE PT SE GR HU 12 ES B G20 20 mbar G25 25 mbar O 12 Er G20 20 mbar G25 25 mbar O 12L G25 25 mbar 12 E G20 20 mbar e 12 ELL G20 20 mbar G25 20 mbar e 12H G20 20 mbar e BE CH ES FR UK AT CH CZ ES Propane categories DK NL NO IT IE PT FI SE IT GR NL DE LU HU I3 P G31 30 mbar O I3 P G31 37 mbar e I3P G31 50 mbar 8 DIAGRAMS OF PRESSURES
9. N 10510100 Outside temperature sensor 12kQ AF120 D D D 0 zn Hemove this AF bridge Factory typical setting setting Description HE 00 Heating mode OFF 01 Heating mode ON fa Lu ea C3 rm Lu co E Co eo un Setting T for the heating water d 85 adjustable between 30 and 85 C T min for the heating water Minimum outside temperature adjustable between 20 and 10 C mm ul CI EN co ES E ES i OS aa adjustable between 15 and 60 C AH E adjustable between 15 and 25 C L 50 pu Ge L EO led na P 5 Maximum outside temperature 1 148 00 Using a outside temperature sensor and a room thermostat L zL IEL OL 6 8 Z2 9 9 v e 2 1 ea C3 Lu S Pg D C3 LE 90 P4 80 O Qs 70 c 60 a d 50 da 3 40 G o 30 2 Ps ki 20 o F 10 0 25 20 15 10 0 5 10 15 20 25 lt gt P6 P7 1 a Outside T C EN 16 INSTALLATION INSTALLATION OF A SIMPLE HEATING CIRCUIT CONTROLLED BY ROOM UNIT LT IT Tr rna AF120 General diagram A Room Unit controls the heating system radiators or convectors The unit allows the selection various central heating functions and can be programmed for up to 3 schedules per week both for heating and hot water production In this configuration the boiler co
10. ca EO Test function Central heating low power Test function Boiler with fixed number of revolutions Ir ea ca EO Status Boiler function CI Lo ea ca Standby no demand for heat Fan first fan after Pu Lee AN AN co La KJ D Ignition MN ea co co Operation of the boiler burner for the heating Operation of the boiler burner for the domestic hot water ER ea EO EO Air pressure limit or obtaining the number of start revolutions The burner goes out when the specified value is reached A demand for heat is present nonetheless Pump over run time after the demand for central heating O tn E 88 E Ea RS E ft amp Pump over run time after the demand for domestic hot water en ea ca ca Burner blocked LO ea ca EO TI gt SG IZ gt GC 2 T1 gt 10 C after 9 seconds FE ae Lo co Pu EN dT 1 dt gt maximum gradient T1 To o fu Pu e LO water pressure switch not off Pu EO no fan signal erroneous fan signal A 1 ma A NTC3 short circuit NTC5 short circuit NTC3 interrupt NTC5 interrupt TS IS max Lu Lu LC DIE E EI Or c EI E D un un Pu wait for the fan to start If the burner is blocked for one of the reasons mentioned above the screen display alternates between a 9 followed by the temperatur
11. of 40 C in 10 minutes In addition to their exceptional hot water supply capability the Prestige Excellence tank in tanks feature A solution for scale deposits thanks to the specially designed corrugations the hot water tank expands and contracts during the heating cycle preventing the formation of scale A guarantee against the risk of Legionnellae Disease and bacteria the hot water tank is fully immersed in the primary circuit and the hot water is constantly kept at a temperature above 60 C Exceptional resistance against corrosion and aggression provided by the stainless steel FROST PROTECTION The boiler is equipped with an integrated frost protection as soon as the NTC1 flow temperature drops below 7 C the system activates the central heating pump As soon as the NTC1 flow temperature drops below 3 C the system automatically ignites the burner until the temperature rises above 10 C The pump continues to run for about 10 minutes If an outdoor temperature sensor is connected to the system the pump is activated as soon as the outside temperature drops below the specified threshold To provide efficient protection for the whole system all valves of the valves on the radiators and the convectors should be com pletely open EN 4 INTRODUCTION PRESTIGE AQUASPEED Chimney connection concentric tubes 80 125 mm Tappot 6 litres AAS PI ane Moedig not available on Prestige Solo
12. 3 9 3 0 3 9 CO max Input G20 25 with front panel closed CO 9 3 9 3 9 3 9 3 9 3 9 3 CO max Input G20 25 with front panel open CO 9 0 9 0 9 0 9 0 9 0 9 0 CO min Input G20 25 with front panel closed CO 9 2 9 2 9 2 9 2 9 2 9 2 Hydraulic parameters Max operating temperature C 90 90 90 90 90 90 Boiler water capacity L 8 8 14 14 16 16 Domestic hot water circuit capacity L 0 9 0 9 54 54 Maximum operating pressure central heating bar 3 3 3 3 3 3 Heat exchanger pressure drop AT 20 C mbar 131 210 131 210 131 210 Capacity of the expansion vessel depend of countries L 12 12 Electrical connection Class IP 30 30 30 30 30 30 Supply voltage V Hz 230 50 230 50 230 50 230 50 230 50 230 50 Maximum absorbed electrical power A 0 8 0 8 1 2 1 2 1 2 1 2 Weight empty kg 48 48 63 63 92 92 EN e 7 TECHNICAL CHARACTERISTICS PROPANE MODEL Solo P AquaSpeed P Excellence P Central heating 24 32 24 32 24 32 Max Input 80 60 C kW 24 30 5 24 30 5 24 30 5 Min Input 80 607C kW 5 9 5 9 5 9 5 9 5 9 5 9 Max output 80 607C kW 23 4 29 6 23 4 29 6 23 4 29 6 Min output 80 60 C kW 5 8 5 8 5 8 5 8 5 8 5 8 Efficiency 30 load EN677 109 109 109 109 109 109 Flue gases Flue gas pipe Max pressure drop Pa 130 130 130 130 130 130 Concentric flue gas channel maximum length Y 80 125 mm m 20 20 20 20 20 20 Gas Category varies by country
13. Check the connection of the NTC5 sensor Check the wiring of the NTC5 sensor Flue gas temperature too high NTC5 If the problem persists replace the NTC5 sensor Press RESET BD Error while reading the parameters If the error persists replace the MCBA Check the MCBA power supply voltage Ba 5 Problem with the power supply to the fan u If it is OK replace the fan EN e 34 CE CE CE CE CE CE CE CE CE CE CO CE CUu IN EN FR NL ES IT DE 01 Horizontal Terminal N OET Terminal Tereminale Waagerechte oulet horizontal horizontal orizzontale Wanddurchf hrung 02 Vertical Terminal DALE Terminal Terminale Senkrechte outlet vertical vertical verticale Dachdurchf hrung 03 Flue pipe Conduite Rookgaspijp Tubo Prolunga Rohr L 250 mm L 250 mm L 250 mm L 250 mm L 250 mm L 250 mm 04 Flue pipe Conduite Rookgaspijp Tubo Prolunga Rohr L 500 mm L 500 mm L 500 mm L 500 mm L 500 mm L 500 mm 05 Flue pipe Conduite Rookgaspijp Tubo Prolunga Rohr L 1000 mm L 1000 mm L 1000 mm L 1000 mm L 1000 mm L 1000 mm Adjustable flue pipe Conduite Regelbare Tubo L 500 mm Prolunga Verstellbares Rohr L 500 mm L 500 mm rookgaspijp L 500 mm L 500 mm 06 i regulable adjustable r glable L 500 mm instelbaar L 325 400 mm regolabile einstellbar L 235 400 mm L 325 400 mm L 235 400 mm L 325 400 mm L 325 400 mm 07 Ss Coude 45 Bocht 45 Codo 45 Curva 45
14. The Prestige is fitted with a 3 4 male fitting connector on which you can connect the gas tap You must comply with the applicable regulations e g NBN D51 003 for gas connections and the other standards in force in the country of installation Where there is a risk of dirt stemming from the network place a gas filter upstream from the connection Prestige AquaSpeed prestige 7 b f Prestige Excellence Cold water supply tap Non return valve Safety group Pressure reducing valve Hot water expansion vessel Thermostatic mixer Drawoff tap NO OS fo ho Drain the gas pipe and check in minute detail that all the boiler pipes both inside and outside are sealed Check the gas pressure in the system Consult the technical characteristics Checkthe gas pressure and consumption when commissioning the appliance EN e 14 INSTALLATION HEATING CONNECTIONS Recommendations The central heating system must be completely flushed out with tap water before connecting the boller Install the automatic air vent on the top of the appliance Prestige AquaSpeed only You will find this in the polystyrene packing The device must be levelled using the provided bracket or the optional wall frame not available for the Prestige Excellence The operating noise can be increased if the appliance is fitted against a wall made of wood or other lightweight co
15. after two RESET attempts replace the MCBA Check that the convection flow through the chimney is not The tacho signal of the blower does nt go to zero high enough to rotate the blower If not exchange the blower Check the connection of the NTC1 sensor E ER MEG Set GE Check the wiring of the NTC1 sensor If the problem persists replace the NTC1 sensor Check the connection of the NIC2 sensor DIr ER TUE Check the wiring of the NTC2 sensor If the problem persists replace the NTC2 sensor EN e 33 MCBA PARAMETERS FOR THE SPECIALIST Codes Description of the fault Resolution of the fault Check the connection of the NTC3 sensor Check the wiring of the NTC3 sensor Pn ca Lu Lu NTC3 short circuit If the problem persists replace the NTC3 sensor Check the connection of the NIC1 sensor Check the wiring of the NIC1 sensor P DO Lu eh NIC1 connection open If the problem persists replace the NTC1 sensor Check the connection of the NTC2 sensor Check the wiring of the NTC2 sensor Pn DO EN n NTC2 connection open If the problem persists replace the NTC2 sensor Check the connection of the NTC3 sensor Check the wiring of the NTC3 sensor Pr Co Lu CO NTC3 connection open If the problem persists replace the NTC3 sensor If the problem persists after two RESET attempts replace the MCBA rr ea Fa JC Internal error
16. checking the electrode 24 Disassembling the heat exchanger 24 AquaSpeed Disassembling the inverted tank 24 Cleaning the heat exchanger 24 Temperature sensor resistance tables 24 MCBA PARAMETERS FOR THE SPECIALIST 25 Standby Mode 29 Settings the MCBA parameters 26 Request for information on the installation 27 Entering the code 27 MCBA parameters with code restricted access 28 Communication Mode 32 Error Mode 32 Safety stop resolution of the fault 33 SPARE PARTS See at the end of this manual EN 2 WARNINGS WHO SHOULD READ THESE INSTRUCTIONS These instructions should be read by the specifying engineer the installer the user the service engineer SYMBOLS The following symbols are used in this manual Essential instruction for the correct operation of the installation Essential instruction for the safety of persons and the environment Danger of electrocution Danger of burns RECOMMENDATIONS AN e Please read carefully this manual before installing and commissioning the boiler e t is prohibited to carry out any modifications to the inside of the appliance without the manufacturer s prior and written agreement e The product must be installed and serviced by trained engineers in compliance with current standards e Any failure to follow instructions relating to tests and test procedures may result in personal injury or risks of pollution e To guarantee safe and correct operati
17. of the information delivered with the appliance and must be given to the user and stored in a safe place An approved installer must carry out the assembly commissioning maintenance and repair of the system in accordance with current standards in force ACV shall not accept any responsibility for damage caused by non compliant location of the system or by use of the parts or connections not approved by ACV for this application IS The manufacturer reserves the right to change the technical characteristics and specification of its products without notice IS The availability of some versions and their accessories is market dependant EN 3 INTRODUCTION DESCRIPTION OF THE SPECIFICATIONS The Prestige is a wal mounted condensing boiler meeting the requirements of the HH Top applicable standards force in Belgium The boiler is certified compliant with EC standards as a connected appliance C13 x C33 x C43 x C53 C83 x but it can also be connected as an open appliance in category B23 LINING The boiler is protected by a steel lining that first of all undergoes a degreasing and phosphation process before being lacquered and heated at 220 C The inside of this lining is coated with a layer of thermal and acoustic insulation reducing losses to a minimum HEAT EXCHANGER The core of the Prestige features a new stainless steel heat exchanger This piece of technology represents the fruit of exhaustive research an
18. programmable room thermostat Key Screen 71177117 Ld MODE Description of Key Screen parameters No communication ERRS Communication between the boiler module and the optional control modules only ERRS STEP Communication between all the devices connected ERROR MODE with code ERROR mode indicates the most recent error as well as the status of the boiler and its readings at the time this error occurred Screen ELO Key MODE Description of screen parameters 4 365 Code mode Status of the boiler at the time of the error nu EO I C3 FAN MODE with code Start temperature T1 at the time of the error Lu EO C3 I IG Fi Return temperature T2 at the time Description of AI OI of the error Key Screen parameters Ld r1 SCT Wai Hot water temperature T3 at FA d EE 51 16 LI the time of the error MODE Ld The current fan speed is eae Outdoor temperature T4 at the 550508 5500 hon 66 LI time of the error STEP EN e 32 MCBA PARAMETERS FOR THE SPECIALIST SAFETY STOP ERROR mode ES To unlock the system e Press RESET on the screen If a fault occurs while the appliance is running the system locks e Contact your installer if the fault happens again and the screen starts to flash The first character is an E and the next two characters give the code for this fault as illustratedin the table below Codes Description of t
19. 11S38dAd INVHOVIG SNIHIM EN e 22 COMMISSIONING AND MAINTENANCE COMMISSIONING THE SYSTEM IS Slowly fill the tank and drain it by opening a hot water tap Drain all the taps and check that there are no leaks in the domestic hot water system Fill the whole system up to a minimum pressure of 1 bar preferably 1 5 bar using the boiler s fill valve Fill the system slowly and drain it using the central heating flow pipe manual air vent Also check that the automatic air vent AquaSpeed on the tank is working Check that there are no leaks in the central heating system Prestige excellence purge the primary circuit of the tank by means of the manual air vent on the top of the tank Purge the circulator s Open the gas valve drain the pipe and check that there are no leaks in the system Check that the siphon is filled Connect the plug to the wall socket and power on the appli ance If needed place the room thermostat to its highest position The boiler should start Check the gas pressure and allow the boiler to heat up for a few minutes Set the boiler to High Power mode and check the CO2 level see the table of Technical Characteristics Then set the boiler to Low Power mode and check the CO2 level again see the table of Technical Characteristics Set the central heating and hot water temperatures following the values given in the Directions for Use Drain the central heating system again and if necessary re fill
20. 13 537D4020 C12 53402088 C11 507F4096 C10 507F4095 C09 537DZ025 537DZ026 Burner propane Br leur propane Brander propaan Quemador propano Bruciatore propano Propangasbrenner Prestige Solo AquaSpeed Excellence
21. 45 pipe bend 4 0 1 3 23 ances within a radius of 0 5 metres around the flue terminal of the Prestige Vertical pipe 20 0 The maximum flue resistance is 130 Pascal You can use the following table as the basis for calculating this value please also Horizontal pipe 15 0 refer to the specimen calculation presented under the table This table is based on the equipment offered by ACV and cannot be applied generally Options for connection to the chimney Sample calculation The diagram below consists of the following parts pipe with monitoring section 2 907 pipe bends 2 metres of horizontal pipe 2 45 pipe bends 2 1 1 metres of vertical pipe and fall back discharge uu OOO Therefore the resistance of this S system is as follows e 2 5 2 x 6 0 2 x 5 0 S 2 x 4 0 4 x 5 0 20 72 5 Pa This value is less than the maximum authorised resistance therefore the installation is compliant wu 0005 A presi L EN e 12 INSTALLATION DOMESTIC HOT WATER CONNECTION 1 Cold water supply tap PRESTIGE SOLO SMART TANK 2 Non return valve 3 Safety group 4 Pressure reducing valve Rinse the installation before connecting the 5 Hot water expansion vessel domestic hot water circuit EE Fill the tank
22. DROPS Pressure drop on the heating side Pressure drop on the domestic hot water side A Pressure drop ofthe boiler B Pressure available for the heating circuit circulator on 1 C Pressure available for the heating circuit circulator on 2 A Pressure drop on the domestic hot water side Prestige AguaSpeed D Pressure available for the heating circuit circulator on 3 B Pressure drop on the domestic hot water side Prestige Excellence ana R I E L 3 Pressure drop bar 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 10 15 20 Flow litres hour Volume of domestic hot water litres minute DOMESTIC HOT WATER FEATURES AguaSpeed Excellence Operating conditions at 807C 24 32 Operating conditions at 807C 24 32 Flow at 40 C AT 30 C L min 11 14 5 Peak flow at 40 C AT 30 C L 10 175 224 Flow at 60 C AT 50 C L min 6 6 8 3 Peak flow at 40 C AT 30 C L 60 733 835 Constant flow at 40 C AT 30 C L h 653 745 Peak flow atv 60 C AT 50 C L 10 102 103 Peak flow at 60 C AT 50 C Lien 352 353 Constant flow at 60 C AT 50 C L h 916 320 Pre heat time minutes 27 25 INSTALLATION INSTRUCTIONS DIMENSIONS Solo AguaSpeed Excellence 1030 632 BOILER ROOM ACCESSIBILITY M
23. Prestige Installation Operating and Servicing Instructions Prestige Solo 24 32 Prestige AquaSpeed 24 32 Prestige Excellence 24 32 prestige EN e 1 INDEX WARNING 3 Who should read these instructions 3 symbols 3 Recommendations 3 Applicable standards 3 Warnings 3 INTRODUCTION 4 Description of the specifications 4 USERS GUIDE 6 Directions for use 6 Settings the parameters 6 TECHNICAL CHARACTERISTICS 7 Natural gas model 8 Propane model 8 Natural gas categories g Propane categories g Diagrams of the pressure drops 9 Domestic hot water features 9 INSTALLATION INSTRUCTIONS 10 Dimensions 10 Boiler room 10 Wall mounting of the boiler 10 Distances of hydraulic connections 11 INSTALLATION 12 Connection to the chimney 12 Domestic hot water connection Prestige Solo 13 Domestic hot water connection Prestige AquaSpeed Excellence 14 Connection to the gas 14 Heating connections 19 Installation of simple heating circuit controlled by room thermostat ACV 15 16 Installation of simple heating circuit controlled by Room Unit 17 Installation of two heating circuits controlled by room thermostat ACV 15 and AM3 1 1 module 18 Installation of two heating circuits controlled by Room Unit and ZMC 1 module 20 ELECTRICAL CONNECTION 22 Wiring diagram Prestige Solo AquaSpeed Excellence 22 COMMISSIONING AND MAINTENANCE 23 Commissioning the system 23 Inspection and maintenance 23 Disassembling the burner 24 Disassembling and
24. Propano Propano Propangas ss N EN FR NL ES IT DE A01 Side panel Lat rale Zijkanten Lateral Laterale Seitenblech A02 Front panel Face avant Frontstuk Parte delantero Pannello anteriore Vorderblech A03 Top cover Couvercle sup rieur Bovenkap Tapa superior Coperchio superiore Obere Abdeckung A04 Hear panel Panneau arri re Achterpaneel Panel trasero Pannello posteriore Hinterblech Control panel Tableau Paneel Panel Pannello ns ABS ABS ABS ABS ABS eee lelie A06 Wall mounting Fixation murale Wandbevestiging Fijaci n mural Fissaggio murale Wandhalterung Control panel Tableau Paneel verlengstuk Elemento izquierdo Elemento sinistro ABS Tafel A07 E M attachment left prolongement gauche links del panel del pannello Verl ngerung links Control panel Tableau Paneel verlengstuk Elemento derecho Elemento destro ABS Tafel A08 i attachment right prolongement droite rechts del panel del pannello Verlangerung rechts Back cover Protection arriere Afschermplaat dal ae Abschirmung hinter iis late displa du displa display achter P dad displa P ze pray pe del display display p ay Jaquette RE Pannello A10 Bottom panel AA Onderpaneel Panel inferior qu Unterblech inferieure inferiore A11 Expansion vessel Support vase Steun expansievat Apoyo vaso Appoggio vaso Trager support d expansion de expansion di espansione Ausdehnungsgefass Prestige Solo AquaSpeed 21475419 A01 21471419 21480069
25. UASPEED EXCELLENCE The Prestige Aguaspeed and Prestige Excellence boilers can be connected directly on the domestic hot water circuit Flush out the system before connecting the domestic hot water part The installation must be fitted with an approved safety unit with a 6 bar safety valve a non return valve and a shut off valve During the heating process the domestic hot water dilates and the pressure increases As soon as the pressure exceeds the safety valve setting the valve opens and discharges a small quantity of water Using a hot water expansion vessel 2 litres at least will prevent this phenomenon and reduce water hammer effect Prestige AquaSpeed If the flow demands become too high the desired water temperature will not be reached To avoid this phenomenon we recommend that you place a flow limiter in the cold water pipe just before the appliance Prestige Excellence Drain the tank by opening a hot water tap Caution the presence of air in the circuit usually causes noisy air discharge effects A DANGER The hot water output temperature may reach temperatures in excess of 60 C which can cause burns We therefore recommend that that you install a thermostatic mixer immediately after installing the appliance Dc If stop valves are used in the domestic hot water system they can cause pressure waves when closed Use devices designed to reduce water hammer to avoid this phenomenon Ke ETON TO THE GAS
26. ake sure that all air vents are unobstructed any times The appliance must be positioned in such a way to be Do not store any flammable products in the boiler room accessible any time In addition the following distances Do not store any corrosive products paint solvents salts are required around the appliance chlorine products and other detergent products near the appliance If you smell gas do not switch on any lights turn off the LLL nn the meter ventilate the rooms and contact your 7 77 M M WALL MOUNTING OF THE BOILER MM M M M M M M M M M Yj The boiler must be mounted on a non flammable wall N Drill two 10 mm diameter holes spaced as indicated on m a bracket with the delivered anchor 777 SCPews YM YU Hook the boiler on the bracket Min 300 mm EN 10 INSTALLATION INSTRUCTIONS DISTANCES OF HYDRAULIC CONNECTIONS SOLO A CH supply 1 F CH return 1 F Supply to the water heater 1 F With Kit DHW 10800079 Return from the water heater 1 F with Kit DHW 10800079 Gas connection 3 4 M DISTANCES OF HYDRAULIC CONNECTIONS AQUASPEED CH supply 1 F CH return 1 F Domestic hot water supply 1 2 M Cold water inlet 1 2 M
27. an plugs 24 Volt the ignition cable the gas valve control and the ignition electrode earth The upper jacket panel is removable for an easier access Loosen the 4 burner nuts using a ratchet wrench Unscrew the three way coupling on the gas pipe In one unit lift up the burner with the fan and the gas valve to remove them from the exchanger Be careful not to damage the burner insulation in the exchanger Check the condition of the insulation and the seals and replace them if necessary before re assembling the burner following the same procedure but in the reverse order DE THE EXCHANGER Drain the water from the central heating system using the connection under the appliance Allow the appliance to drain completely Dismantle the electrical connections downstream from the burner as well as the NTCs Dismantle the exchanger central heating flow pipes and return pipes Exercise caution when dismantling the parts as residual water may escape from the exchanger Dismantle the connection at the siphon and remove the nut between the siphon and the exchanger Lift up the exchanger in one piece standing upright The exchanger detaches from its hook and is fully released Checkthe condition of the seals and replace them if necessary before re assembling the AQUASPEED DISASSEMBLING THE INVERTED TANK Disconnect all the central heating connections as well as all the hot and cold water pipes connected to the boiler Em
28. ansi n di espansione T connection of Raccord en T du ji SAS BG Conexi n en T Collegamento T T Verbindungs B16 sanitair warm DHW Tank pr parateur ECS water boiler del acumulador del bollitore stuck Speicher Prestige Solo AquaSpeed 497B0031 507F4083 507F4086 507F4035 507F4088 63962009 55744014 55744014 507F4089 507F4087 507F4052 507F4053 B06 557B4002 507F4054 507F4068 B01 497B0031 507F4066 Dr sa B10 557A4017 i TA B08 30538481 507F4069 B04 557A4014 557A7008 B02 63962009 d c 507F4071 B05 507F4070 507F4066 B06 557B4002 PA n 507F4055 ss N EN FR NL ES IT DE m EI a Venturi i C01 Venturi seal Venturi joint Venturi dichting Venturi junta a Venturi dichtung Guarnizione C02 Fan Ventilateur Ventilator Ventilador Ventilatore Gebl se Silicone seal Joint silicone Siliconedichting Junta de silicona Guarnizione silicone Silikondichtung C03 i i i fan ventilateur ventilator ventilador del ventilatore Gebl se C04 MN I Ontstekingselectrode AAS i ED Z ndelectrode electrode d allumage de encendido di accensione C05 Electrode seal Joint lectrode Dichting electrode Jun
29. be a minimum of 1 bar and must be checked by the end user on a regular basis lf the pressure drops under 0 5 bar the integrated water pressure switch blocks the appliance until the pressure in the system returns to a level above 0 8 bar The connection for a fill valve is provided underneath the appliance The installer can also fit the system with a separate valve Make sure that the appliance is powered off when filling the system TTo do this toggle the Start Stop switch located on the left of the screen to Off see the Control panel For more information please ask your installer when the system IS delivered A safety valve is provided at the underneath of the appliance If the system pressure exceeds 3 bars this valve opens and drains the water from the system In this case please contact your installer SETTING THE PARAMETERS Also see the user label located inside the valve on the control panel GUIDE Setting the domestic hot water temperature Hot water temperature Press Mode The screen displays PARA Press Step the first character is 1 and the last two characters give the current hot water temperature setting To change this temperature press or until the last two digits show the desired temperature value Press Store to save the new temperature setting Press Mode twice to return to Pilot mode normal operating mode Enabling or disabling the hot water heating mode hot water Pr
30. before filling the heating circuit 7 Drawoff tap 5 7 4 7 Optional accessories 1 2 Or 3 Code Description 6 Nu i i Y Domestic hot water hydraulic kit M vi Kit to connect a Prestige Solo boiler to an external water heater The kit includes one circulator one NTC sensor 12kQ L 3 2 m one check valve three copper pipes gaskets Y 10800079 NTC sensor 12kQ Senses the temperature in the external hot water tank Delivered with the kit 10800079 5476G003 AN Before any work on the boiler it is important to disconnect the power Supply It is important to carry out all the electrical connection before changing the MCBA parame ters 1 The 12kQ NTC sensor must be inserted into the dywell and connected on terminals 3 and 4 See the picture below 2 Connect the DHW pump to the dedicated connector on the internal wiring see the wiring diagram E ER gt Es Ea gt factury typical setting Description Domestic hot water temperature setting H E setting to be adjusted between 60 and 80 C e en CO 00 DHW Mode OFF 01 DHW Mode ON Pu EO CI nu EO sal 12 Tank with NTC sensor 13 Tank with control thermostat i O E A NR CO oot EO Mu Ly Li mm mm oo Mul Pu Ln EN 13 INSTALLATION DOMESTIC HOT WATER CONNECTION PRESTIGE AQ
31. ctrode earth but make sure the serrated washer is fixed between the earth cable and the electrode T C RO T C RO T C RO when re assembling s 20 98200 25 12000 70 2340 Check the condition of the seals and replace them if necessary 15 75900 30 9800 75 1940 before re assembling the electrode following the same procedure but in the reverse order AB 22800 SS Zee Ed ud 5 45900 40 6650 85 1470 3 O 36100 45 5520 90 1260 5 28600 50 4610 95 1100 10 22800 55 3860 100 950 19 18300 60 3250 5 20 14700 65 2750 EN e 24 MCBA PARAMETERS FOR THE SPECIALIST STANDBY MODE Once the cause of the blockage has been resolved the burner starts automatically within 150 seconds at most Standby Mode SEbls After you power down the appliance the screen displays Pilot mode as shown in the figure above Status Boiler function o ea CC EO Internal check three way valve This is the standard MCBA mode The MCBA automatically returns to this mode after 20 minutes if no keys have been pressed on the screen Any parameters that were modified are then enabled Ca co LO LO Boiler burner in hot water ready function SE Lo Ln D Test function Central heating high power The first character shows the current status of the boiler depending on the condition of both the boiler and the burner The last 2 characters indicate the start temperature ES 2
32. d intensive laboratory testing It reflects ACV s eighty years of experience in using stainless steel for heating and hot water functions The particular geometry of the exchanger pipes is calculated to obtain a very large Reynolds number throughout its cycles The Prestige achieves an exceptional output that remains stable throughout the boiler s life given that it causes no oxidation on the exchanger which is manufactured entirely from quality steel BURNER ACV uses its BG 2000 M burner for the Prestige this is an air gas premix burner providing safe and silent operation while limiting emissions NOx and CO to an incredibly low level Although the ACV BG 2000 M boiler is very modern it uses proven technology and is manufactured from standard spare parts that are easily available on the market TEMPERATURE REGULATION The basic version of the Prestige is fitted with a microprocessor controlled regulator MCBA which takes over both the safety functions ignition monitoring the flame limiting the temperature etc and control of the boiler temperature This MCBA also includes a weather dependent regulator All you need to do is connect the outdoor temperature sensor available as an option to the device However this regulator can also operate with a standard on off room thermostat In addition with the combination of a weather dependent regulator and a room thermostat you can control the tempera tures based on the weather with compen
33. djust those two circuits depending on the outside temperature This is the ideal configuration for floor heating with additional heating provided by radiators You can select various heating functions and program up to three weekly schedules as well for the central heating as for the hot water production Optional accessories Code Description Room Unit RSC 10800034 Supplied with outside temperature sensor ZMC 1 module kit 10800119 Controls the second heating circuit alarm contact operates only in conjonction with the Room Unit RSC Clip in interface RMCIEBV3 E 19890058 Enables communications between the MCBA and the Room Unit RSC 10800045 Ti Ge o cue B Controlled circuit 10510900 Ge Ud Ue on circuits 10510100 Outside temperature sensor 12kQ AF120 10800077 o eos and integrated wall brackets 10800097 High temperature kit DN20 Including one circulation pump two isolating valves check valve two thermometers Low temperature kit DN20 10800096 Including one circulation pump two isolating valves check valve two thermometers the 4 way valve with integrated bypass Servomotor SQK 349 10800019 Electromechanical servomotor SQK 349 for the three way valve included in low temperature kit opening times 150 seconds EN e 20 INSTALLATION u eter tor 6 18 919 1e zlrl To be wired in accordance with the applicable regulations
34. e two last digits and b with the error code EN e 25 MCBA PARAMETERS FOR THE SPECIALIST SETTING THE MCBA PARAMETERS Parameter Mode PAA To access Parameter mode when the system is in Pilot mode press MODE once To scroll through the list of parameters simply press step To modify a parameter value use the or keys Then press Store to save the value you just changed The screen flashes once to confirm the data has been saved To activate the parameters you changed press MODE once more which brings you into Info mode However if you do not press a key the system returns to Pilot mode after 20 minutes and automatically enables the changes Key Screen I eara MODE Factory setting Key Screen Description of parameters Solo AquaSpeed Excellence EB E Adjusting the hot water temperature ED EB BO STEP 00 Stop ON Sari mm i is em Wu n eo i Ui 03 Start pump continuously on STEP 00 Stop J 7 Ub dy 3 Im 35 mM n J G Tumor MIN 3845 i AI the heating STEP O3 Start pump continuously on SPD erra heating mode 411815 Mias 5 STEP EN 26 MCBA PARAMETERS FOR THE SPECIALIST REQUEST FOR INFORMATION ENTERING THE CODE ON THE INSTALLATION Info Mode Ez Code Mode You can access the following parameters by entering the service To switch from Standby to Info mode press Mode twice code e Parame
35. ele E se se Prestige 24 28 mr gg nin gg nin M ber of f LA LI LI LILI M mum uno ez STEP hot water mode rpm ja 2 AE TEE TOG been 1188 propane maus oss lt EER Prestige 24 E B Minimum number of fan neues ges BEE BBEI 1 H5 EI D revolutions rpm x 100 _ _ STEP opus E EER EE core EEE EEE E EHE sie Tod FEER free Prestige 24 mim rn nin OGG Minimum number of fan natural gas OG AA ee GG d Son T Prestige 32 ni ni ni ind propane ga L 21218 LI 88 LI rete Ea Hee Wee tras EEN iH E ea EO LU EN Co EO Lu en Prestige 24 Ld P 119 Number of fan revolutions natural gas HI gt i at ignition rpm x 100 megse SE a _ ind propane EIE BBE 1135 pee E DG 1135 D ea ea CI un ea ea CI un ea Oo C3 un 85 rni CH pump over run J JE 0 10 sec step 1 minute D di Domestic hot water pump over run time step 10 2 sec am OO m an co 20 CI m Co DO m ON STEP FR e 29 MCBA PARAMETERS FOR THE SPECIALIST Factory setting Key Screen Description of parameters Solo AquaSpeed Excellence D D Pu Pu CO oo C3 Lu Da oo Co Lu CO Co C3 Lu Central Heating modulation hysteresis enabled Central Heating modulation hysteresis disabled 0 oo Pu Ly ea ea CI Lu ea Lo CI Lu D ea CI LU Domestic hot water modulation hysteresis enabled O ea Pu El ea ea C3 CI ea co ES Pu ea ea C3 CI Domestic hot water modulat
36. ess Mode The screen displays PARA Press Step twice the first character is 2 and the last two characters give the current setting 00 disabled 01 enabled To change this parameter press or until the screen displays the desired value 00 disabled 01 enabled Press Store to save Press Mode twice to return to Pilot mode normal operating mode Enabling or disabling Central Heating mode heating Press Mode The screen displays PARA Press Step three times the first character is 3 and the last two characters give the current setting 00 disabled 01 enabled To change this parameter press or until the screen displays the desired value 00 disabled 01 enabled Press Store to save Press Mode twice to return to Pilot mode normal operating mode Setting the central heating temperature maximum temperature for the heating circuit Press Mode The screen displays PARA Press Step four times the first character is 4 and the last two characters give the current central heating temperature setting To change this temperature press or until the last two digits show the desired temperature value Press Store to save the new temperature setting Press Mode twice to return to Pilot mode normal operating mode Fault The temperature setting for the appliance and the safety functions for its various parts are continuously monitored by a regulator controlled by a
37. he fault Resolution of the fault Check the wiring short circuit in the 24V wiring Abnormal flame signal Check the electrode Replace the MCBA water damage Pr EO C3 C3 Check the ignition cable No flame signal after five attempts at firing the boiler Check the electrode and the position of the electrode Check that there is gas at the burner Pr ea I Pu If the problem persists after two RESET attempts replace the MCBA Pr EO Lu Internal error m EO Fa Persistent lock Press RESET m EO Ea un If the problem persists after two RESET attempts replace the MCBA Internal error m ea CI ad If the problem persists after two RESET attempts replace the MCBA m ea en EPROM error Check the wiring Check the 24V fuse on the MCBA m ea Pu Max input thermostat open or 24V fuse gone Pr oo m Ui If the problem persists after two RESET attempts Internal error replace the MCBA m E SS Check the NTC wiring and replace if necessary Z O o 148 AS If NTC1 is OK please verify that the water flows trough the boiler 127 208 Check the NTC wiring and replace if necessary Check that the pump is turning VEER If there is no problem with the pump drain the system Check the fan control connection Check the fan wiring t es No fan signal present If the problem persists
38. he presence of residual water from tests completed on the appliance Therefore we recommend that you unblock the pumps before filling the appliance You will find the connection for the filing valve and or drainage valve on the bottom of the appliance Fill the appliance to a minimum pressure of one bar Drain the whole system and re fill the appliance to a pressure of 1 5 bar The system must be designed to ensure a continuous flow in the central heating circuit If this flow is not guaranteed for example if using thermostatic valves you should install a pressure dependent bypass in the system Fit the siphon fill it with tap water and connect the hose to the drain using a connection with an inspection section Make sure you prevent the freezing of the condensates T e EN 15 INSTALLATION INSTALLATION OF A SIMPLE HEATING CIRCUIT CONTROLLED BY ROOM THERMOSTAT ACV 15 att ana mm LI cc AF120 General diagram The On Off room thermostat controls the central heating system radiators or convectors If an outside temperature sensor is connected the boiler continuously adjusts its operating temperature depending on the outside temperature The pump is powered as soon as the room thermostat generates an heat demand Advantages for the user Comfort Maximum Output Simplicity of the system Optional accessories Code Description a 10800018 Room themostat ACV 15
39. ion hysteresis disabled So Lo Pu un ea ea C3 e D ea C3 D ea Lo C3 e Detection of domestic hot water hysteresis enabled O Oo Pu en ea D En CI D Lo En CI ea D CI Detection of domestic hot water hysteresis disabled D eo Tu Ir am oo Ca Ca CO Co C3 Ca CO CO C3 Ca Central Heating blockage time sec x 10 2 D CO nu Oo eo ea C23 un EO DO I un CO CO C3 Lh Domestic hot water blockage time sec x 10 2 O EO My LO EO EO C3 I EO EO C3 C3 CO EO C3 C3 Domestic hot water Central Heating blockage time sec x 10 2 a ea Ubi Ca CO Co Pu CI CO Co Co un Co Co Pu Ca Re modulate the difference T1 T2 0 ea Lu ea ea Lu c3 ea ea Uy CI ea ea LU CI Shell address 1 disabled D EO Ly Pu EO CI ea CI ea CI Temperature increase set point for the production of hot water QU Oo Lu Lu CO D Pu Ca eo eo m C3 CO D Pu I sel el U U U U U U U U U U U U first position 2nd heating circuit 0 disabled 1 enabled slave D 3 y 2 enabled master TEEF BB8 EEB STEP Second position the demand for heat comes from O the room thermostat 1 the outdoor sensor 1 LI EN e 30 A D lt U MCBA PARAMETERS FOR THE SPECIALIST Factory setting Screen Desc
40. it Make sure the central heating system is correctly balanced and If necessary adjust the valves to prevent a greater or lesser flow than planned to some circuits or radiators CHECKING THE SETTINGS Check that the parameters are set in accordance with the users needs see page 3 Directions for Use Check the boiler settings this task can only be carried out by an ACV trained installer or by the ACV maintenance department set the appliance to High Power mode by simultaneously pressing the mode and Plus keys Check the dynamic gas pressure at the gas valve see diagram below ref 7 This must be at least 18 mbars Wait a few minutes for the appliance to heat up to a minimum temperature of 60 C Check the CO2 setting using a measure ment instrument Please see in the Technical Characteristics for optimum value To increase the CO2 value turn the venturi screw counterclockwise turn it clockwise to reduce the value see diagram below ref 2 Then put the appliance to High Power mode by simultaneously pressing the mode and Plus keys Wait a few minutes to stabilise Check the CO2 value It should be either equal to the full power value or a maximum of 0 5 less than this value If you record Ref 3 The gas valve offset setting is a sealed factory setting In principle it may not be modified a significant deviation please contact the ACV maintenance department INSPECTION AND MAINTENANCE A ACV recommends that you ha
41. m temperature of the second heating circuit E EO CO un El ea EO un Setting T for the heating water adjustable between 30 and 85 C Minimum temperature of the second heating circuit L Ee Gi Se Lu C3 CH un o el Gel E3 c3 en ea uu C3 CO Mm ca En tolli jala am za E T min for the heating water adjustable between 15 and 60 C Minimum outside temperature T4 adjustable between 20 and 10 C Maximum outside temperature T4 adjustable between 15 and 25 C Booster Oo Eu A Bo mS Pam ER Ed Es LU aal sal ES t EA eel EO led CR Fa o COM ad ER ed Es Mu C3 el E3 Edi EO EO e CI CH ea EO Nu The high T circuit is controlled depending on the outside T and the room thermostat The low T circuit is controlled depending the outside T only T departure boiler C a o a lt gt D o o EN 19 DS MR RS 25 20 15 10 5 0 5 10 15 20 25 gt lt gt P6 P7 Outside T C INSTALLATION INSTALLATION OF TWO HEATING CIRCUIT CONTROLLED BY CONTROL UNIT AND ZMC 1 MODULE General diagram This configuration controls two heating circuits radiators or floor heating In addition the Room unit features a remote monitoring of the two circuits You can a
42. microprocessor the MCBA In the event of a fault this MCBA disables the appliance and displays an error code the screen flashes displaying E as the first character followed by the error code To reset the appliance Press Reset on the screen Contact your installer of the fault happens again TECHNICAL CHARACTERISTICS NATURAL GAS MODEL Solo AquaSpeed Excellence Central heating 24 32 24 32 24 32 Max Input 80 607C kW 24 32 24 32 24 32 Min Input 80 607C kW 5 9 5 9 5 9 5 9 5 9 5 9 Max output 80 607C kW 23 4 31 23 4 31 23 4 31 Min output 80 607C kW 5 8 5 8 5 8 5 8 5 8 5 8 Efficiency 30 load EN677 109 109 109 109 109 109 Flue gases CO emissions max min Input mg kWh 45 20 52 20 45 20 52 20 45 20 52 20 NOx emissions EN483 mg kWh 66 66 66 66 66 66 NOx classification EN483 5 5 5 9 5 5 Flue gas temperature max Input 80 607C C 70 76 70 76 70 76 Flue gas temperature max Input 50 30 C C 37 39 37 39 37 39 Mass flow rate of combustion products kg h 38 52 38 52 38 52 Flue gas pipe Max pressure drop Pa 130 130 130 130 130 130 Concentric flue gas channel maximum length 80 125 mm m 20 20 20 20 20 20 Gas Category varies by country 2E S B 2Er 1 2H 2ELL 2L I 2E Gas pressure mbar 20 25 20 25 20 25 20 25 20 25 20 25 G20 gas flow rate m3 h 2 5 3 4 2 5 3 4 2 5 3 4 G25 gas flow rate m3 h 3 0 3 9 3 0
43. mperature of the 2nd central heating circuit o EO Lu Ba For further information please contact our after sales STEP department EN e 27 MCBA PARAMETERS FOR THE SPECIALIST MCBA PARAMETERS WITH CODE RESTRICTED ACCESS Factory setting Key Screen Description of parameters solo AquaSpeed Excellence PIS onsec ew BEBE PER ES EN onm Hg HUB OO EIB Maximum outdoor temperature adjust the heating curve 0 oo z3 ea D e D eo En D ea D CO Frost protection temperature 0 oo Ca CO CO D C3 m CO oo I m CO DO Ca m CO oo Ca I CO EO Ca CI eo EO Ca Ca Correction based on the outdoor temperature 0 Disabled 188 Acceleration time lag 00 Stop minute O D EN D ea a ea ea En CI ea D CI 0 D Pu ea ea CI ea ea En CI ea D CI Night set back heating C m m m m m m m m D LO sie TG SS Ld p Maximum number of fan iss ager gacr 11913 STEP MM restos32 mag MSS MSB d sie OA ESO E perme Nam ruber at fan sie EGO CM EME STEP aie d sie ag EEBB EEEE MCBA PARAMETERS FOR THE SPECIALIST Factory setting Key Screen Description of parameters Solo AquaSpeed Excellence m FB EE 867 Max number of revs din ue EE BAL Oot 2115 in domestic hot water mode rom 100 ne gg Sg FEB nnde Ei EEE EE r
44. nstruction Using rubber absorbers can reduce this effect The connections to the central heating system and the domestic hot water system are provided with nuts This simplifies the assembly with the optional wall frames If you do not use the wall frames then you must use flat connection type fittings with flat gaskets The central heating safety valve is incorporated under the appliance and must be routed to the drain with an open onnection to allow inspection The central heating pump is located inside the appliance You can change its speed using the three position switch depending on needs or if the pipes are noisy The wall frames of the Prestige AquaSpeed and Solo are fitted with an integrated 12 litre expansion vessel HEATING CONNECTIONS GENERAL By pass with differential pressure valve Isolating valve heating system Safety valve calibrated to 3 bar with pressure gauge System filling valve Expansion vessel Drain cock Country dependant the Prestige Excellence is equipped with a 12 litres expansion vessel This is sufficient for systems with a capacity of approximately 120 litres for the central heating For larger capacity systems you can add a suitable expansion vessel to the AquaSpeed the Prestige Solo and the Prestige Excellence for the central heating Fill the system with fresh water Contact your ACV representative about the use of inhibitors It is possible that the pumps are locked due to t
45. ntinuously ajusts its operating temperature in function of the outside temperature Optional accessories Code Description E Room Unit RSC AA 19890034 Delivered with outside temperature sensor Clip in interface RMCIEBV3 10806036 Activates the communication between the MCBA and the Room Unit RSC 10510100 Outside temperature sensor 12k02 AF120 m ea D D u ES typical setting Description 00 Heating mode OFF 01 Heating mode ON uj 97 o Es HER lt Lu EO EI Setting T for the heating water adjustable between 30 and 85 C EO CO un E e CO un T min for the heating water adjustable between 15 and 6070 ea ul C3 C3 un CG Po EO EO Lu CI C3 un O i i NR i CO 10800036 Interface address 0 mmm mm unm Pm a Ze II DI PO N N N e EN e 17 INSTALLATION INSTALLATION OF TWO HEATING CIRCUIT CONTROLLED BY ROOM THERMOSTAT ACV 15 AND AM3 11 MODULE ATT N I Fo AF120 General diagram EE This is a simple way to control two heating circuits radiators or floor heating You can adjust those two circuits depending on the outside temperature This is the ideal configuration for floor heating with additional heating provided by radiators The floor heating temperature is adj
46. on of the appliance it is important to have it serviced and maintained every year by an approved installer or maintenance company e n case of anomaly please call your service engineer Despite the strict quality standards imposed by ACV during the manufacture inspection and transport of its appliances you might notice some errors Please report immediately any fault to your approved installer Remember to note the fault code displayed on the screen e The parts may only be replaced by genuine factory parts You will find a list of the spare parts and their reference number ACV to the end of this document e The burners are preset in our factory for use with natural gas equivalent to G20 e An ajustement of the CO2 is not allowed in Belgium 2E s B AN e t is important to switch the boiler off before carrying out any work e There are no user accessible parts inside the boiler casing APPLICABLE STANDARDS The appliances carry the GE mark in accordance with the standards in force in the various countries European Directives 92 42 EC Efficiency 90 396 EC Gas appliances They also carry the HR TOP label Gas condensation boilers WARNINGS IF YOU SMELL GAS Immediately shut off the gas intake Open windows for fresh air flowing Do not use any electrical appliances and do not actuate any switches Immediately notify your gas supplier and or your installer This documentation is part
47. pty the central heating system using the fill drain valve located under the appliance Disconnect the electrical connection for the charging pump by pulling out the plug Hemove the MCBA assembly plate Unscrew the central heating flow pipe using the three way coupling located on top of the charging pump Unscrew the mini tank return pipe Disconnect the hot and cold water pipes from the mini tank Hemove the air vent located above the mini tank as well as the nut located below Hemove the mini tank from the lining and tilt it forwards to remove it completely Check the condition of the seals and replace them if need be before re assembling the mini tank en THE HEAT EXCHANGER Remove the burner assembly as described above Remove the burner gasket Clean the combustion chamber using a vacuum cleaner Disconnect the flue pipe from the exchanger Check if the condensates collector is clean if necessary clean it Check the burner insulation and the burner gasket replace the parts if necessary Check the igniter replace if necessary Reassemble the burner and check for leakages Power up the appliance set the boiler in full power mode and recheck for leaks Check the gas pressure and the CO2 level as explained in previous paragraf DISASSEMBLING AND CHECKING THE ELECTRODE Remove the ignition cable Remove the two fixing screws TEMPERATURE SENSOR RESISTANCE TABLES Remove the ele
48. ription of parameters Solo AquaSpeed Excellence First position Domestic hot water pump 1 or three way mixer tap 2 a DO Lu un CO eo m Lu CO 20 m CI Co eo m Mo second position tank with NTC3 probe 2 or tank with thermostat 3 al U U U U U U U So Lo Lu e ea 3 CI EN Co c3 CI ea lt a CI EN Manual fan number of revolutions First position Fan control pump level during burning in Second position Fan control pump level during over run time CO DO m m CO CO CO EO CI m C3 nm CO Co CO Co CI m C3 m CO eo CI Ca Hold temperature Maximum temperature for the start heating curve for the 2nd circuit D D D ea ea ea Ly Ly Ly LO EO J eo ea un Co CO oo un ZJ CO DO un Ca Minimum temperature for the start heating curve for the 2nd circuit Ke Co md CI ea Lo Pu c3 ea ea nu c3 D Lo Pu CI O DO Pa m ea ea C3 Lu CO ea Co Lu ea cea C3 Lu 2nd circuit temperature hysteresis First position Special pump O disabled D co En Pu co co C3 Co OO ea Co C3 DO ea C3 Co second position Minimum disable cycle 0 disabled EN e 31 MCBA PARAMETERS FOR THE SPECIALIST COMMUNICATION MODE with code When in this mode the system displays the communication between the boiler and the control module the optional interface kit or the optional
49. s Y 1 2 Y 3 4 Prestige Excellence Prestige Solo Valvola di sicurezza 3 bar 1 2 3 4 Sicherheitsventil 3 bar Y 1 2 Y 3 4 Manual air vent 3 4 Purgeur manuel Y 3 4 Prestige AquaSpeed Manuele ontluchter 3 4 Purgador manual 9 3 4 Prestige Excellence Prestige Solo Valvola di spuro manuele 3 4 Manueller Entlufter 3 4 Automatic air vent Purgeur automatique Prestige AquaSpeed Automatische ontluchter Valvola di spurgo autom tico Prestige Excellence Prestige Solo Purgeur automatico Automatischer Entlufter Drain cock valve 1 27 Robinet de vidange 1 2 Prestige AquaSpeed Leegloopkraan Y 1 2 Grifo de vaciado 1 27 Prestige Excellence Valvola di scarico 1 27 Entleerungshahn 1 27 557A6006 Non return valve Prestige Solo Clapet anti retour Terugslagklep Prestige AquaSpeed V lvula anti retorno Volvola di ritegno Prestige Excellence Ruckschlagventil MCBA burner control Module de contr le MCBA Brander module MCBA M dulo de control MCBA Centralina MCBA MCBA Brennersteuerung 5476G014 Prestige AquaSpeed 24 kW 5476G015 Prestige Excellence 24 kW 5476G016 Prestige Solo 24 kW 5476G025 Prestige Solo 32 kW Propane Propane Propaan
50. sation for the indoor temperature There are four user adjustable parameters By entering a Special maintenance code qualified installers can access several other parameters to adapt the boiler to special requirements In principle these parameters are factory set for all normal applications PRODUCTION OF HOT WATER e Prestige Solo is custom designed to operate for heating only or in combination with the whole range of ACV water tanks The SmartLine range is the number one choice for domestic applications To simplify the installation of such a combination ACV has designed a specific hot water connection kit easy to be incorporated inside the casing e Prestige AquaSpeed has a constant supply of hot water from its 6 litre tank that is directly and immediately available lt combines all the advantages of hot water storage and immediate production instant hot water without the need for additional hot water storage The Prestige 32 AquaSpeed provides 13 3 litres of hot water per minute at 40 C instantly and without waste AT 30 C The AquaSpeed mini tank is made of stainless steel and the hot water is heated by means of a copper coil in the tank e Prestige Excellence combines all the advantages of ACV s Tank in Tank systems with the comfort and space saving of a wall mounted boiler in a 63 cm wide casing it includes a 62 litre stainless steel Tank in Tank The Prestige 32 Excellence supplies 258 litres of water at a temperature
51. ta de electrodo E eus SING elettrodo Elektrode C06 BOE oe Joint rampe Dichting Junta de rampa Guarnizione rampa Dichtung br leur branderstaaf quemador bruciatore Brennerlanze Burner flange Isolation plaque Dichting Aislamiento Isolamento piastra Isolierung C07 i A insulation br leur branderflens placa quemador bruciatore Brennerflansch C08 Burner seal Joint br leur Branderdichting Junta de guemador Guarnizione Brennerdichtung 210 mm 210 mm 210 mm 210 mm bruciatore 210 210 mm C09 Burner rod Rampe br leur Branderstaaf Rampa quemador Rampa bruciatore Brennerlanze C10 Burner flange Plaque br leur Branderflens Placa quemador Piastra bruciatore Brennerflansch C11 zn GOD negare Vlamcontrole Tapa de llama Spioncino fiamma SERIO window de flamme Flamme C12 Gas valve Bride vanne Gasklepflens Brida de v lvula Piastra valvola Flansh Gasventil flange 1 2 gaz 1 2 1 2 de gas 1 2 gas 1 2 1 2 C13 Orifice Opercule Diafragma Diafragma Diaframma Diafragma 52 mm 52 mm 52 mm 52 mm 52 mm 52 mm C14 Gas valve Vanne gaz Gasklep V lvula de gas Valvola gas Gasventil C15 Venturi O ring O ring venturi O ring venturi Anillo venturi Anello venturi O Ring venturi C01 537D4034 C02 537D3041 C03 557A0054 C04 557DZ023 C05 557A0012 C06 557A0048 C07 51700061 C08 557A0058 O C15 557D6039 C14 537D4033 C
52. ters 5 42 screen e Communication mode e Fan Speed mode dH _ e ERROR mode PAA Press STEP until the system displays the information you need The point located behind NE li the first position flashes to indicate that the boller is in J INFO mode To access Code mode press MODE and STEP simultaneously only from Standby mode lt lt m m lt Description of Screen parameters EB Start temperature T1 in C LJ gt MODE STEP Press STEP once and the system displays C in position 1 followed by arbitrary characters in positions 3 and 4 Pu Oo un CI Return temperature 2 in C Lu D eh un Hot water temperature T3 in C M gt cw STEP Pa DO Ca Lu Outdoor temperature T4 in C Press or to change the code un CO In un Flue gas temperature gt t aa e Co Pa Un Start temperature calculated in C Press STORE the screen flashes briefly to indicate that the code has been accepted J Lo C3 CI Rate of increase in the start LJ FT IG temperature in C s my t 88 STORE Press MODE until the system Glen Rate of increase in the return g displays the correct mode L temperature in C s Rate of increase in the hot water temperature in C s LO EO I Ca K3 Only AGV authorised installers know the access code m m m m m m m m m D U U U U U U U U U lt Start te
53. usted on a first temperature diagram while the radiator loop follows a second temperature diagram if needed with a booster function Optional accessories Code Description 10800018 Room thermostat ACV 15 AM3 11 module 10800095 Controls the second heating circuit communicates directly with the MCBA Contact sensor 12kQ NN To be mounted on the outlet of controlled circuit Contact thermostat RAM 5109 10510900 Required to protect all floor heating circuits Collector 2 circuits DN20 10800077 With bypass connecting tubes and integrated wall brackets EK d 10510100 Outside temperature sensor 12k2 AF120 d High temperature kit DN20 10800087 Including one circulation pump two isolating valves check valve two thermometers Low temperature kit DN20 10800096 Including one circulation pump two isolating valves check valve two thermometers the 4 way valve with integrated bypass Servomotor SOK 349 10800019 Electromechanical servomotor SQK 349 for the three way valve included in low tempera ture kit opening times 150 seconds EN 18 fer jar tor 6 8 9 e vle 2 1 ESESES Ke 0 y uj on e Es 50 Ej 02 Lu EO CJ m L1 D CH D typical 0 0 ct ct J 0 INSTALLATION T Ee a Sei a idm Description 00 Heating mode OFF 01 Heating mode ON N Y N PANA Description Maximu
54. ve your boilers inspected and cleaned if need be at least once a year Plug out the appliance before undertaking any work even if only recording Measurements and adjusting the settings Check that the siphon is not fouled fill it if need be and check that there are no leaks Check that the safety valves are operating correctly Drain the whole system and if necessary re fill the appliance to pressure of 1 5 bar A If you have to refill your circuit more than twice a year please contact your installer Check the boiler charge in High Power mode If there is a big difference between this value and the original setting the devia tion could mean a blockage in the air intake pipes or flue gas extraction pipes or that the exchanger has become fouled with an accumulation of dirt AquaSpeed Check the domestic hot water flow and the temperature These values could indicate a poorly regulated flow limiter new setting or In areas where the water is very hard gradual scale formation in the exchanger To clean the AquaSpeed minitank with chemicals you can connect the descaling pump directly to the hot and cold water connection Follow the manufacturer s instructions for using the descaler and the descaling product or contact your ACV distributor for more information EN e 23 COMMISSIONING AND MAINTENANCE DISASSEMBLING THE BURNER Close the inlet gas valve Remove the front panel of the boiler Unplug the f
55. z Gas pijp Tubo gas Tubo gas Gasrohr Domestic hot Prepara teur Sanitair warm Acumuador A Selle Brauchwasser B08 OU mini pr parateur de agua caliente d acqua calda E water Tank water boiler ipe Mat bereiter ECS sanitaria sanitaria DET Tube de an Tubo de conexi n Tubo di Verbiedingungsrohr B09 raccordement ed del circulador collegamento del Warm Wasser connection pipe i sanitair circulator s i em circulateur ECS sanitario circolatore sanitario Lade pumpe DHW loading pump Circulateur ECS SAD EAD Circolatore sanitario Ad B10 1 L 130 mm 1 130 mm circulator sanitario EE Lade pumpe 1 L 130 mm 1 L 130 mm 1 L 130 mm Or Tube d part Vitgang pijp Tubo de salida Tubo di mandata Vorlaufrohr B11 M dis del circulador da lo circolatore Warm Wasser outlet pipe circulateur ECS sanitair circulator agis A sanitario sanitario Lade pumpe Heating Tube retour EE Tubo retorno Tubo di ritorno B12 verwarming ka Heizungsruchlaufrohr return pipe chauffage pijo de calefacci n riscaldamento en ie ER EE Koudwateraanvoer Tubo de llegada de ul Kalteswasser B13 cold water eau froide p A KANA acgua fredda ja EA piip agua fria sanitaria EN Eintritssrohr inlet pipe sanitaire sanitaria Domestic e Tubo salida Tubo di mandata Tube d part Uitgang sanitair B14 hot water de agua caliente acqua calda Warm Wasserrohr i ECS warm water pijp Ms Ge Outlet pipe Sanitaria sanitaria B15 ION hans Expansievat Maa ii SCH Ausdehnungsgef vessel d expansion exp

Download Pdf Manuals

image

Related Search

prestige 24 32 mk2 6 prestige 32 for sale uk prestige 32 a vendre prestige power porter mk8 24v for sale prestige-16 prestige-21 prestige 36 for sale mk prestige 2 compartment dado prestige 32 bretagne nord prestige-14 prestige classic 2.0 what is prestige in mm2 d\u0027or 24k prestige price prestige pic 2.0 v2 prestige 2026 ii a prestige products and prices