Home

Monitor Station V2 Owner`s Manual English

image

Contents

1. 10 11 Monitor Station V2 Owner s Manual On the Monitor Station V2 press the ST1 Main Source and Speaker A Speaker Select buttons so they light Make sure no other sources or speakers are turned on In your DAW or on your noise generator pan the pink noise all the way to the left since we ll start by calibrating the left speaker Make sure your pink noise source isn t going through any signal processing so it s as clean as possible Begin playing pink noise you shouldn t hear it since you turned everything down in step 1 If you do hear it repeat step 1 Set the Monitor Station V2 s front panel Main Output Level knob to Unity Gain by turning it fully clockwise Set the Monitor Station V2 s rear panel Speaker A Output trim to fully clockwise You may begin hearing the test tone playing through your speakers Begin slowly increasing the input level on your left speaker until your SPL meter is showing 80 dB SPL or the target level you ve chosen Repeat steps 6 10 for the right speaker Calibrating Additional Speaker Systems Repeat the steps above for your other monitoring systems making sure to zero each system s Speaker Output trim in step 2 and pressing the appropriate speaker system button in step 4 After you ve set up additional monitoring systems you can test your calibrations by playing audio through Speaker A only and then making no other adjustments toggling Spe
2. StudioLive Al mixer S PDIF digital output 00000000 eS FireStudio Project computer interface mobile phone eve le le recorder headphone amp O O powered speakers A nacciva cnaakarc R CD player speaker C powered subwoofer 12 2 Getting Started Monitor Station V2 2 3 Advanced Modes Owner s Manual 2 3 Advanced Modes The Monitor Station V2 offers some powerful options that allow you to configure it for the way you like to work You can set the operating mode of its e Speaker Select buttons e Main and Cue Source buttons e LED meter Select the desired operating mode by pressing the appropriate button as you power up the Monitor Station V2 In the following sections we explain the modes and tell you the button to hold down to select each one You can set a single mode during each power up so don t hold down two buttons at the same time as you turn on the Monitor Station V2 To return to the Monitor Station V2 s original mode settings perform a factory reset as described in Section 2 3 4 2 3 1 Speaker Select Modes Hold down Speaker Select To select So that Speaker A Combo mode all of the Speaker Select buttons and therefore all of your speakers can be active at the same time This i is the MERI mode Speaker B B Togglemode mode only one speaker system can be selected ata time one speaker system can be selected at a time
3. 14 3 1 3 Line Outputs 75 3 1 4 Power 15 Controls 76 The Front Panel 16 4 1 1 Talkback 16 4 1 2 CueControl 16 4 1 3 AuxControl 17 4 1 4 Main Source Control 17 4 1 5 Speaker Control 18 4 1 6 Main Level Controls 18 Resources 19 Audio Specifications 79 Frequently Asked Questions 21 Troubleshooting 21 PreSonus Limited Warranty 22 1 Overview Monitor Station V2 1 1 Introduction Owner s Manual id Introduction MONITOR Thank you for purchasing the Monitor Station V2 As with all PreSonus products it s built with high grade components to ensure optimum performance that lasts a lifetime The Monitor Station V2 is based on the acclaimed Monitor Station with a new ergonomic design that makes it even easier to use It also features new input options for today s engineers producers and artists The result is the perfect desktop monitoring and communications system for the modern studio Please contact us at 1 225 216 7887 with any questions or comments you have about your Monitor Station V2 PreSonus Audio Electronics is committed to constant product improvement and we highly value your suggestions We believe the best way to achieve our goal of constant product improvement is by listening to the real experts our valued customers We recommend you read this manual to familiarize yourself with the Monitor Station V2 s features applications and c
4. Note that the Mono button has no effect on the Main L R Line Outputs Mute Button Press the Mute button so it lights to silence the Monitor Station V2 s output to its connected speaker systems Note that the Mute button has no effect on the Main L R Line Outputs Dim Button Press and light the Dim button to quickly reduce the outputs to your speakers without changing the setting of the Main level control knob Dim is useful for example when you receive a phone call during a session or when you want to talk to someone in the control room without shouting during recording or playback The Dim level is set with the Attenuation knob Attenuation Knob The Attenuation knob sets the level of the speaker outputs when the Dim button is lit 5 Resources 5 1 Audio Specifications Monitor Station V2 Owner s Manual 5 Resources 5 1 Audio Specifications Audio Inputs Internal Talkback Microphone Gain Range Type Sensitivity Stereo 1 and Stereo 2 Inputs Type Input Impedance Balanced S N Ratio 1 kHz 10 dBu Unity Gain THD N unwtd 1 kHz 0 dBu Output Unity Gain Frequency Response 0 5 dB Noise Floor 20 Hz to 20 kHz 150 Q input termination Maximum Input Level Minimum Gain 1 kHz 0 5 THD N Auxiliary Inputs Type Input Impedance S N Ratio 1 kHz 10 dBu Unity Gain THD N unwtd 1 kHz 0 dBu Output Unity Gain Frequency Response 0 5 dB Gain Range Maximum Input Level Minimum Gain 1 kHz
5. 5 Turn up the output level control of your primary audio source until the Monitor Station V2 s LED meter s red 0 VU LED lights Reality vs Unity Gain The master output fader or knob on many audio devices has a Unity Gain marking that shows the position at which the output s level isn t being raised or lowered and is therefore at its optimal position This is usually marked as a 0 setting If you find that the output setting of your audio source needs to be way above or below its Unity Gain marking in order to light the Monitor Station V2 s 0 VU LED you may need to recalibrate the Monitor Station V2 s LED meter to better accommodate the device Adjust the meter s range as described in Section 2 1 3 then repeat steps 2 5 in this section 6 Forthe audio sources connected to the ST2 and Aux Inputs repeat steps 2 5 selecting the appropriate source in step 4 Ideally these devices also need to be able to produce a test tone 2 1 5 Connecting Speakers to the Monitor Station V2 1 Zerothe Monitor Station V2 s front panel Main Output Level knob and rear panel Speaker A Out trim by turning them fully counterclockwise 2 Connect your primary monitoring system such as a pair of powered nearfield reference monitors to the Monitor Station V2 s A L R Speaker outputs 3 If you have a second set of monitors connect them to the Monitor Station V2 s B L R Speaker outputs 4 If you
6. oz CUE N2 3 lav Output Level Leve Level IV ain ue Source Source Source Source AUX Input MAIN Main Source Speaker Select 0 2 A 4 6 12 16 24 e Attenuation y W um a IE F pa 18011 Grand Bay Ct Baton Rouge JAVIVITAO Louisiana 70809 USA 1 225 216 7887 T d www presonus com Part 820 MS20029 B
7. with different equipment clients and purposes may benefit more from one of the many other methods available If you want to calibrate your studio monitors using a different method we encourage you to do so What You ll Need Pink Noise In the following steps you ll calibrate your speakers using 500 Hz to 2 5 kHz bandwidth limited pink noise at a level of 20 dBFS When calibrating a subwoofer use 40 Hz to 80 Hz bandwidth limited pink noise Many DAWs include a tone generator that produces this type of pink noise and can be set to this level You can also download the required pink noise audio files for playback in your DAW from a variety of free Web sites or you can purchase a tone generator or test tone CDs from an electronics or entertainment retailer If need be you can use the chorus of a modern commercial rock song as a quick and dirty substitute for pink noise Note dBFS stands for decibels full scale This is a measurement of amplitude level in digital systems where there s a finite maximum available level before clipping occurs This maximum level is referred to as 0 dBFS In a digital device with analog outputs such as an audio interface the analog to digital and digital to analog converters are configured so that 0 dBFS equals a certain amount of voltage For example a 0 dBFS tone playing at Unity Gain from an AudioBox 1818VSL or FireStudio Project audio interface measures 10 dBu It s important to
8. 0 5 THD N S PDIF Type Dynamic Range THD N Maximum output at 0 dBFS Sample Rates Input Meters ST1 ST2 and Aux only Type Sensitivity Range Audio Outputs Type Output Impedance Balanced THD N unwtd 1 kHz 0 dBu Unity Gain Frequency Response 0 5 dB Speaker A B and C Trim Range Main Level Range Dim Attenuation Range 15 to 55 dB electret condenser 42 dB Ya TRS Active Balanced 10 kQ 2100 dB 0 00596 10 Hz to 65 kHz 90 dBu 3 20 dBu RCA Active Unbalanced 47 5 kQ 2100 dB 0 00596 10 Hz to 50 kHz 60 dB to 20 dB 20 dBu RCA 75 0 coax 113 dB 0 002596 1 kHz 1 dBFS 18 dBu 44 1 48 88 2 96 kHz Dual 8 segment LED w peak hold 24 dB to 0 dB Ya TRS Active Balanced 510 0 0196 10 Hz to 50 kHz 80 dB to 0 dB 80 dB to 0 dB 30 dB to 6 dB 5 Resources 5 1 Audio Specifications Cue Cue Level Range Dim Attenuation Talkback activated Headphones Type Maximum Output 60 0 load Frequency Response 1 0 dB Power Power Supply Type Input Connector Type Monitor Station Input Voltage Range Power Requirements Continuous Physical Dimensions Height Depth Width Weight 20 Monitor Station V2 Owner s Manual 80 dB to 0 dB 20 dB Va TRS Active Stereo 150 mW channel 10 Hz to 50 kHz External DC Transformer Internal Line Barrel 5 5 mm outside diameter 2 1 mm inside diameter 18 VDC 10W 2 5 63 5 mm 8 5
9. Output knob to Unity Gain by turning itfully clockwise and then adjust the amplifier s input level as necessary 2 1 9 Connectthe Main Outputs The Main L R Line Outputs provide what s essentially a thru circuit for the Monitor Station V2 s input sources They re typically used to feed external devices that need a constant full strength input signal such as tape machines or digital stereo recorders The audio they carry is determined by the Main Source described in Section 3 1 4 and their output level is equal to the original input source level 1 Turn the input and output levels of the external device to be connected all the way down 2 Connectthe inputs of the external device to the Monitor Station V2 s Main L R Line Outputs 3 Calibrate the device s audio levels according to its user manual or visit its manufacturer s Web site for information about the recommended calibration process 2 Getting Started Monitor Station V2 2 2 Basic Hookup Diagram Owner s Manual 2 2 Basic Hookup Diagram Here s a typical Monitor Station V2 setup In this example the input sources are an audio interface a CD player a mobile phone and a StudioLive Al series mixer s S PDIF digital output Two monitoring systems for auditioning mixes are connected along with a subwoofer The Cue L R outputs are connected to a headphone distributing amplifier and the Main L R outputs are feeding a digital recorder y headphones
10. know the voltage your device references to prevent overloading the input of the Monitor Station V2 SPL Meter In order to measure the sound pressure level in your environment you ll need an SPL meter You can purchase an inexpensive SPL meter from an electronics retailer or download an SPL meter app for your phone Make sure your SPL meter can take C weighted measurements and offers a slow response time When calibrating reference monitors in a studio the acoustic level or sound pressure level SPL should be measured from the mixing position at seated ear height Essentially you want the meter to measure SPL from where you listen so position it A Q roughly where the middle of your head would be in terms of height and distance from the speakers We re assuming you follow the standard practice of listening from N N a location facing an imaginary point precisely in the center of your speakers creating No an equilateral triangle v SPL meter You can place your SPL meter on a music stand or some other stationary structure so that it doesn t pick up handling noise or move during the procedure 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual If you have multiple monitor systems connected to your Monitor Station V2 be sure to use exactly the same method for calibrating all of the systems This will allow you to switch between them without experiencing disorienting volume changes as you co
11. unaffected by the Monitor Station V2 s controls such as an external digital or CD recorder Why won t the Monitor Station V2 change modes for me e You must be holding down the mode changing button the instant the power switch is flipped on e Set the mode according to Section 2 3 e Youcan only set one mode per power up so don t try to hold two buttons down at once 5 3 Troubleshooting Please check the PreSonus Web site www presonus com regularly for updates and support documentation Online technical support is available at http www presonus com support Contact Technical Support Technical support is available via email at techsupport presonus com PreSonus telephone technical support is available to customers in the USA on Monday through Friday from 9 a m to 5 p m Central Time by calling 1 225 216 7887 Customers outside of the USA should contact their national or regional distributor for telephone technical support A list of international distributors is provided at www presonus com buy international distributors 21 5 Resources Monitor Station V2 5 4 PreSonus Limited Warranty Owner s Manual 5 4 PreSonus Limited Warranty PreSonus Audio Electronics Inc warrants this product to be free of defects in material and workmanship for a period of one year from the date of original retail purchase This warranty is enforceable only by the original retail purchaser To be protected by this warranty the purchaser must co
12. 216 mm 9 228 6 mm 6 lbs 2 72 kg 5 Resources Monitor Station V2 5 2 Frequently Asked Questions Owner s Manual 5 2 Frequently Asked Questions Why can t I hear the Talkback microphone Only headphones whose Source switch is in the Cue down position can hear the Talkback microphone Why do see levels on the LED meter but can t hear anything through the speakers The LED meter measures the Monitor Station V2 s input so seeing a level is only half the story e Connect and calibrate your speakers according to Section 2 1 6 e Ensure the correct Speaker Select button is lit and that its rear panel Speaker Level Adjust knob is turned up e The Main Output Level knob may be turned down Disengage the Talk Mono Mute and Dim buttons and then slowly turn up the Main output level knob e Move your speakers to a different output to verify its original outputs are functioning properly e Connect the input source directly to your speakers to verify the speakers are functioning properly I have everything turned all the way up but my speakers still aren t loud enough What gives The Monitor Station V2 is not an amplifier Its speaker outputs should be connected to the inputs of a powered speaker or to a soeaker amplifier The only outputs with separate gain controls are the headphone amplifiers Why doesn t the Main output level knob control the Main Out L R line outs The Main L R line outs are for devices requiring a signal
13. Instructions 1 Inalarge pot combine whole chicken leg quarters water quartered onion Old Bay 2 bay leaves and 1 whole clove garlic Cover and bring to a low boil Simmer stock until chicken is falling off the bone Remove the chicken and set aside Discard the onion bay leaves and garlic reserving the liquid 2 In a heavy saucepan heat 1 Tbsp of the oil on medium high heat and brown the andouille until it is cooked through Set aside sausage for later 3 In the same saucepan add and heat remaining oil Slowly add flour 1 2 Tbsp at a time stirring continuously Continue cooking and stirring the roux until it is a dark brown it should look like melted dark chocolate Be careful to not to get the oil too hot or the flour will burn and you ll have to start over 4 Oncerouxhas reached the correct color add diced onion celery green pepper and minced garlic Cook until vegetables are very tender Do not cover Slowly add 1 quart of chicken broth and bring to a low boil stirring constantly Transfer roux mixture to a soup pot and bring to low boil Do not cover the roux will settle on the bottom of the pot and burn Add remaining chicken broth bay leaves and thyme Simmer for 30 minutes While gumbo is simmering debone and shred chicken and slice the andouille Add chicken and andouille to gumbo and return to a simmer Simmer for 30 45 minutes ol ecu i m O Stir in frozen okra and parsley and bring to a rolling boil 1 Op
14. Level knob 5 Engagethe talkback microphone by pressing the Talk button the level of the audio in your headphones is lowered 6 Begin speaking into the talkback microphone slowly turning up the talkback Level knob until you can hear yourself speaking through the headphones but your voice isn t loud enough to annoy the performers 2 1 8 Connectthe Cue Outputs In addition to the four individual amplified headphone jacks on its front panel the Monitor Station V2 provides rear panel Cue L R Line Outputs that you can connect to a separate headphone amplifier Their audio is selected using the front panel Cue Source buttons as described in Section 4 1 2 You can set their level using the front panel Cue Output knob as explained in Section 4 1 2 Here s how to calibrate a headphone amplifier 1 Zerothe Main Level and Cue Output knobs by turning them fully counterclockwise Y Vf d 9 O 10 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual 2 Connect the inputs of the headphone amplifier to the Monitor Station V2 s Cue L R Line Outputs 3 Calibrate the device s audio levels according to its user manual or visit its manufacturer s Web site for information about the recommended calibration process Note If the headphone amplifier doesn t have a recommended calibration process increase the Monitor Station V2 Cue
15. Monitor Station V2 m SEN mam xi L E Hd m y L Jum aa p A ll ARAFA l cir Tr ray ARRAD A CON BR ET G1 A amp Til ef A e YW VEEL NR ue BR S S d Ww 7 ER 4 Br Ai PreSonus CUE Source T AUX Input ASA Level AUX SPDIF r OOO T D NECS Level Level Level Level Main Cue Source Source Source Source Main Source Speaker Select T E onus www presonus com Attenuation Table of Contents 3 1 1 1 1 2 1 3 2 2 1 2 2 2 3 Overview 7 dd Introduction 1 Features 2 What s in the Box 2 Getting Started 3 4 Quick Start Guide 3 41 2 1 1 Connecting the Monitor Station V2 s Power 3 2 1 2 Connecting Devices to the Monitor Station V2 s Inputs 4 2 1 3 Calibrating the Monitor Station V2 s LED Meter 5 2 1 4 Setting the Output Level of Your Audio Sources 5 2 1 5 Connecting Speakers to the 5 Monitor Station V2 6 5 1 2 1 6 Calibrating Your Speaker Levels 7 2 1 7 Calibrate the Talkback Microphone 10 3 2 2 1 8 Connect the Cue Outputs 10 5 3 2 1 9 Connect the Main Outputs 11 5 4 Basic Hookup Diagram 12 Advanced Modes 13 2301 2 3 2 2 3 3 2 3 4 Speaker Select Modes 13 Main and Cue Source Modes 13 Input LED Meter Modes 13 Reset All Modes to the Factory Default 13 Hookup 74 The BackPanel 14 3 1 1 Inputs 74 3 1 2 Speaker Outputs
16. ON v2 K K A 4 1 1 Talkback The Monitor Station V2 s Talkback system allows you to speak through the Cue system to your performers Talkback Microphone The built in electret condenser Talkback microphone is positioned just above the Talkback Level knob Talkback Level Knob This adjusts the gain level of the Talkback microphone preamplifier from 15 to 55 dB Talk Button The Talk button engages and disengages the Talkback microphone preamplifier The Main and Cue audio are automatically dimmed while the Talkback mic is turned on The Talkback button can be operated in two ways e Press and hold down the Talkback button to use the Talkback mic releasing it when the mic is no longer needed e Press the Talkback button and quickly release it to activate the Talkback mic Press and quickly release it again to turn off the mic when it s no longer needed 4 1 2 Cue Control The Cue section of the front panel allows you to manage the Monitor Station V2 s Cue system and control its four individually controllable headphone outputs Each output has its own input selector and its own volume control Cue Source Buttons The Cue Source buttons select the audio routed to the Cue L R Line Outputs and to any Phones output whose source is set to its Cue position down 16 4 Controls 4 1 The Front Panel 4 1 3 Aux Control AUX Input RE Bip Level Monitor Station V2 Owner s Manual Press ST1 to select
17. Speaker C Toggle A B mode you always hear a subwoofer connected to Speaker C as you toggle between the A and B speaker systems 2 3 2 Main and Cue Source Modes Hold down Main Source To select So that STI Input Sum mode all of the Main and Cue Source buttons can be active at the same time Input Toggle mode only one Main source and one Cue source can be selected at a time This is handy when you re comparing input sources against each other such as when you A B your mix against a commercial CD whose mix you re using as a reference 2 3 3 Input LED Meter Modes Hold down Cue Source To select So that the LED meter references 0 VU to 4 dBu Use this if any of your monitoring devices have a maximum input of 4 4 dBu mode dBu or if none of your input devices have a maximum or nominal output level greater than 4 dBu the LED meter references 0 VU to 10 dBu Use this if any of your monitoring devices have a maximum input of 10 ST2 10 dBu mode l dBu or if none of your input devices have a maximum or nominal output level greater than 10 dBu the LED meter references 0 VU to 18 dBu Use this if any of your monitoring devices have a maximum input of AUX 18 dBu mode 18 dBu or if none of your input devices have a maximum or nominal output level greater than 18 dBu 2 3 4 Reset All Modes to the Factory Default Hold down the Mono button during power up to reset all of the modes to their factory d
18. aker A off and Speaker B on You may hear a slight tonal variance due to the different acoustic properties of the monitoring systems but the loudness should remain consistent If it doesn t you may want to recalibrate your speaker systems Calibrating a Subwoofer If you re calibrating a speaker system with an independent subwoofer such as a 2 1 system repeat steps 4 and up with the following changes Press the Speaker C button to light it make sure all other speaker buttons are turned off Pan your pink noise to the center in step 5 For step 6 use 40 Hz to 80 Hz bandwidth limited pink noise 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual 2 1 7 Calibrate the Talkback Microphone 1 Zero the Main Output level Talkback level Cue output individual headphone level and Dim attenuation knobs by turning them fully counterclockwise 2 Connect headphones to any one of the Phones outputs and select Cue as the source by pressing the corresponding Source button so that it latches in its down position 3 Play some typical audio such as a song on your phone or an existing project and select that audio source as your only input to the Cue bus as described in Section 4 1 2 4 Puton the headphones you connected in step 2 and set them to a comfortable listening volume by turning up the corresponding
19. efault settings 13 3 Hookup Monitor Station V2 3 1 The Back Panel Owner s Manual 3 Hookup 3 1 The Back Panel 00000 00 O ed ellertele ac ede 3 1 1 Inputs ST1 L R Connect the left and right channels of your primary stereo source to these balanced 4 TRS jacks ST2 L R Connect the left and right channels of your secondary stereo source to these balanced 4 TRS jacks S PDIF Connect a digital audio device with an S PDIF output to this RCA digital input The Monitor Station V2 supports sample rates of 44 1 48 88 2 and 96 kHz L R Aux Connect the left and right channels of an auxiliary analog audio device to these unbalanced RCA jacks Aux In Connect the headphone jack of a phone portable music player or other device with a stereo 1 8 output to this unbalanced 1 8 stereo input 3 1 2 Speaker Outputs ororo OOO Speaker A L R Outputs Connect your primary powered speaker system to the balanced A L R Speaker Outputs 14 3 Hookup 3 1 The Back Panel 3 1 3 Line Outputs 3 1 4 Power Monitor Station V2 Owner s Manual Speaker B L R Outputs Connect your second powered speaker system to the balanced B L R Speaker Outputs Speaker C L R Outputs Connect your third powered speaker system or subwoofer to the balanced C L R Speaker Outputs Speaker Output Trim A B and C These trims fine tune the levels of the speaker outputs When possible they should be set fully clockwi
20. f none of your input devices has a maximum or nominal output level greater than 18 dBu Press and hold the Cue Source Aux button while powering on your Monitor Station V2 2 1 4 Setting the Output Level of Your Audio Sources Your audio sources sound their best through the Monitor Station V2 when their outputs are set correctly To optimally set the output level of an audio source the source should be able to produce a 1 kHz sine wave test tone either by playing one back or by generating it from an internal oscillator You can find and download free test tone audio files from the internet if necessary When using a test tone make sure there s no processing EQ compression reverb and so on in your test tone s audio path so the tone is as clean as possible 1 Zero the Monitor Station V2 s front panel Main Output Level knob the Cue Output knob and the individual headphone Level knobs by turning them fully counterclockwise 2 Turn down the outputs of the primary audio source connected to ST1 to their lowest setting 3 From your primary audio source play your 1 kHz sine wave tone at a level of 0 dB 4 Onthe Monitor Station V2 press the ST1 Main Source button so that it lights to select the primary audio source make sure that no other Main Source buttons are turned on 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual
21. have a third pair of monitors or a subwoofer connect them to the Monitor Station V2 s C L R Speaker outputs Note If using a subwoofer make sure the Monitor Station V2 is set to Combo mode or Toggle A B mode as described in Section 2 3 1 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual 2 1 6 Calibrating Your Speaker Levels Speaker calibration sets the output level of your speakers so that a specific level shown on the Monitor Station V2 s meter equals a specific acoustic level in your studio as measured in dB SPL The meter level most typically used for calibration is O VU Calibrating your speakers provides a few important benefits First calibration establishes a comfortable maximum level for your studio environment A healthy monitoring level for a small control room environment would be 78 dB For a large environment 85 dB makes more sense You can estimate the best listening level for room sizes in between Calibration also ensures that your left and right speakers are precisely balanced with each other This enhances stereo imaging and more critically allows you to trust the stereo panning you hear as you work When you perform a speaker calibration you separately set the level of each speaker to the same value Note PreSonus does not suggest that the calibration method described here is necessarily the best or the only worthwhile method of speaker calibration Different studio environments
22. he Monitor Station V2 a powerful tool for monitoring your recording and mixing sessions e Four stereo analog inputs two stereo pairs of balanced 4 TRS one unbalanced stereo 1 8 TRS and one stereo pair of unbalanced RCA inputs e S PDIF digital input e Main Source buttons for selecting and comparing inputs e Cue Source selectors for customizing headphone Cue mixes e Three stereo pairs of balanced 4 TRS speaker outputs e Speaker output trims for fine calibration of speaker output levels e Speaker Select buttons for quick A B ing of selected input sources between connected monitoring systems e Dim button with variable attenuation level e Mono button Mute button and Main Output Level knob e Built in Talkback microphone with variable input gain e Four built in headphone amplifiers with stereo unbalanced 4 TRS outputs e Individual Level knobs for each headphone output e Main Cue Source selector for each headphone output 1 3 What sin the Box qb PreSonus MONITOR STATION v2 D y In addition to this manual the Monitor Station V2 package contains the following e Monitor Station V2 Studio Control Center e Monitor Station V2 external power supply e PreSonus Health Safety and Compliance Guide e PreSonus sticker e PreSonus product catalog 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual 2 Getting Started 2 1 Quick Start Guide The Monitor Station V2 Q
23. ks are active 4 1 4 Main Source Control Main Source Buttons The Main Source buttons select the audio for the Speaker Output jacks the Main L R Line Outputs and any headphone amplifiers whose Source switch is set to its Main position up Press ST1 to select the audio input source connected to the rear panel ST1 L R Inputs Press ST2 to select the audio input source connected to the rear panel ST2 L R Inputs Press Aux to select the Aux audio input source according to the setting of the Aux SPDIF switch described in Section 4 1 3 When it s shipped from the factory the Monitor Station V2 s Main Source and Cue Source buttons are set to Input Sum mode so they can all be selected at the same time For more information on selecting other operating modes for these buttons refer to Section 2 3 Main Input LED Meter The Main LED meter shows the level of the Main input audio source When more than one source is selected it Shows the active sources combined level By default the Input LED meter has a reference level of 0 VU 10 dBu For more information on changing the Input LED meter s reference level refer to Section 2 3 4 Controls Monitor Station V2 4 1 The Front Panel Owner s Manual 4 1 5 Speaker Control Speaker Select Buttons Press the Speaker A B or C button to turn on the corresponding monitoring system The Speaker Select buttons provide a great way to quickly compare your mix on different sets of reference monitor
24. mpare your mixes and recordings on the different systems Note Since various speaker systems sound different from each other you ll still hear timbral changes when you jump between speaker sets after calibration After all that s why monitoring with multiple systems helps ensure your mixes and recordings sound good wherever they re played Calibrating Your Primary Speakers 1 monitors N 7 v SPL meter This speaker calibration method sets up your primary speakers so that the Monitor Station V2 s O VU meter level produces a certain acoustic level In the following steps we ll use 80 dB SPL as our target this is a sensible level for a small to medium sized environment You may want to use another target level between 78 dB and 85 dB that is more appropriate to the size of your space Zero your speakers input knobs On many powered monitors the input knob is labeled Input Sensitivity Consult each monitor system s documentation or the manufacturer s Web site for more information about adjusting the speaker input level Zero the Monitor Station V2 s front panel Main Output Level knob the Cue Output knob individual headphone Level knobs and the rear panel Speaker A Output trim by turning them fully counterclockwise 3 Position your SPL metering device as described above 2 Getting Started 2 1 Quick Start Guide
25. mplete and return the enclosed warranty card within 14 days of purchase During the warranty period PreSonus shall at its sole and absolute option repair or replace free of charge any product that proves to be defective on inspection by PreSonus or its authorized service representative If you are located in the USA and need warranty repair please submit an online technical support request at http support presonus com to receive a return authorization number and shipping information If you are located outside of the USA please contact the PreSonus distributor for your region for warranty repairs All inquiries must be accompanied by a description of the problem All authorized returns must be sent to the PreSonus repair facility postage prepaid insured and properly packaged PreSonus reserves the right to update any unit returned for repair PreSonus reserves the right to change or improve the design of the product at any time without prior notice This warranty does not cover claims for damage due to abuse neglect alteration or attempted repair by unauthorized personnel and is limited to failures arising during normal use that are due to defects in material or workmanship in the product Any implied warranties including implied warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this limited warranty Some states do not allow limitations on how long an implied warranty lasts so the ab
26. n to the Monitor Station V2 s rear panel power input 4 Turn on the Monitor Station V2 s power by pressing the Power switch symbol at the top of the 2 Getting Started Monitor Station V2 2 1 Quick Start Guide Owner s Manual 2 1 2 Connecting Devices to the Monitor Station V2 s Inputs 1 Zero the Monitor Station V2 s front panel Main Output Level knob the Cue Output knob and the individual headphone Level knobs by turning them fully counterclockwise 2 Connect your primary audio source computer audio interface mixer or other stereo source to the balanced 4 TRS ST1 L R inputs on the back of your Monitor Station V2 3 If you have a secondary stereo audio source or cue audio source such as other interface outputs or the auxiliary outputs of your mixer connect it to the balanced TRS ST2 L R inputs The Monitor Station V2 can accommodate a variety of analog and digital input sources Here s how to attach them Phone personal music player or other device with 1 8 stereo output Connect the output to the rear panel 1 8 Aux In jack using an unbalanced stereo 1 8 cable With a phone or personal music player the headphone jack is its output Analog audio device with RCA outputs Connect the device s outputs to the Monitor Station V2 s rear panel unbalanced RCA AUX L R IN jacks 2 Getting Started Monitor Station V2 2 1 Quick Start G
27. onnection procedures before trying to connect it to other equipment This can prevent problems that might otherwise occur during installation and setup We appreciate the support you have shown us through the purchase of this product and are confident that you will enjoy your Monitor Station V2 1 Overview 1 2 Features 159 Features Summary of Features Monitor Station V2 Owner s Manual The Monitor Station V2 is outfitted with the key monitor management features needed in a modern studio High quality components ensure that it doesn t color the sound of your tracks and mixes Its built in Talkback mic makes communicating with your performers simple and painless The stereo inputs in the Monitor Station V2 accommodate audio interfaces mixing consoles outboard gear phones personal music players CD players and many other audio sources Up to four input sources can be monitored together or by toggling between input and Aux sources for quick comparisons or for reference Three stereo outputs allow you to connect three sets of powered reference monitors and easily switch between them Manage your listening environment during recording and playback using the Monitor Station V2 s master Mute Dim Mono and Level controls The individual Source and Level controls for the Monitor Station V2 s four amplified headphone outputs allow you to individually configure and adjust what s heard in each performer s headphones All of this makes t
28. ove limitation may not apply to you In no event will PreSonus be liable for incidental consequential or other damages resulting from the breach of any express or implied warranty including among other things damage to property damage based on inconvenience or on loss of use of the product and to the extent permitted by law damages for personal injury Some states do not allow the exclusion of limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty only applies to products sold and used in the United States of America For warranty information in all other countries please refer to your local distributor PreSonus Audio Electronics Inc 18011 Grand Bay Court Baton Rouge LA 70809 USA 1 225 216 7887 WWW presonus com Dinner is Served Added bonus PreSonus previously Top Secret recipe for Chicken and Andouille Gumbo Ingredients e 1CAII Purpose flour e 34 C Vegetable Oil e 1 large onion diced e 1small onion quartered e 6celery stalks diced e 1 large green bell pepper diced e 3 cloves garlic 2 minced 1 whole e 1lb link Andouille sausage e 4Chicken leg quarters e 4qt water e 4 bay leaves e 1tsp thyme e 1 tsp Old Bay seasoning e 1 2 C frozen okra sliced e 4C fresh parsley minced e 6 8 eggs optional Cooking
29. s by switching between them We recommend calibrating your monitors as described in Section 2 1 6 so that the only differences you hear as you switch between monitors reflect the tonal characteristics of each speaker set By default the Speaker Select buttons operate in Combo mode so they can all be turned on at once For quickly switching between them you may want to switch to Toggle mode To learn how to change Speaker Select modes see Section 2 3 4 1 6 Main Level Controls This area contains your primary listening controls for the Monitor Station V2 Main Level Control Knob Control your listening volume with this knob which sets the Monitor Station V2 s output level to its connected speaker systems Mono Button To listen to your audio in mono press this button so it lights When Mono is lit the Monitor Station V2 sums the stereo Main input sources to mono signal It s always a good idea to check a stereo mix in mono to make sure you have no phasing issues that need to be corrected Phasing problems can cause elements of a mix to be canceled or reinforced causing decreases or increases in volume Phase issues also can result in an unexpected swirling in the audio when stereo mic pairs have been used during recording Listening to your stereo mix in mono is also important when you think that some listeners may hear your mix in mono This may be the case when the mix is to be used in compressed Internet videos for example
30. se for Unity Gain Main L R Line Outputs Monitor Station V2 passes input audio sources directly to the Main L R Line Outputs These outputs derive their signal directly from the currently selected Main input sources and are unaffected by the Main level control knob and the Mono Mute and Dim buttons Connect these balanced 4 TRS jacks to the inputs of a stereo device Cue L R Line Outputs The Cue L R outputs derive their signal from the Cue Source selection and their level is controlled by the Cue Output knob Connect the balanced Va TRS Cue L R Line Outputs to a stereo headphone distribution amplifier Power Input Connect the supplied power supply unit to a grounded AC outlet and then to this input WARNING Before connecting the Monitor Station V2 s included power supply make sure that the power supply meets the input voltage requirements of the region or country in which you re using it PreSonus supports only the power supply shipped with your Monitor Station V2 If the power supply doesn t meet your local requirements or if you wish to purchase an additional power supply please contact your local dealer or distributor Power Switch To turn on the Monitor Station V2 press in the at the top of the Power switch To turn it off press the 0 at the bottom of the switch 4 Controls Monitor Station V2 4 1 The Front Panel Owner s Manual 4 Controls 4 1 The Front Panel ANE PreSonus MONITOR STATI
31. the audio input source connected to the rear panel ST1 L R Inputs Press ST2 to select the audio input source connected to the rear panel ST2 L R Inputs Press Aux to select the Aux or S PDIF audio input source according to the setting of the Aux SPDIF switch described in Section 4 1 3 When shipped from the factory the Monitor Station V2 s Cue Source and Main Source buttons are set to Input Sum mode so they can all be selected at the same time For more information on selecting other operating modes for these buttons refer to Section 2 3 Phones Outputs You can connect a set of stereo headphones to each Phones output The outputs accommodate 1 4 TRS stereo connectors Level Knobs The Level knob beneath each Phones output controls the output s volume Source Switches Each Phones output can carry either the currently selected Cue sources or the currently selected Main sources When the switch is up the Main source is routed to the jack Press the button down to select the Cue source Cue Output Knob This adjusts the level of the rear panel Cue L R Line Outputs Aux Input Knob This knob sets the level of the Aux Auxiliary inputs Aux SPDIF Switch This switch selects either the analog Aux In jacks or the digital S PDIF input When the switch is up the analog inputs are active Press the button down to select the digital S PDIF input When the analog Aux In jacks are selected both the rear panel RCA and the 1 8 Aux In jac
32. tional Crack one egg into a teacup and quickly pour into the boiling gumbo Repeat with the other eggs being careful not to cluster them too closely After all the eggs have risen back to the surface reduce heat and simmer 12 Correct seasoning with salt and pepper red white and or black if necessary 13 Serve over rice with potato salad Serves 12 2014 PreSonus Audio Electronics Inc All Rights Reserved AudioBox CoActual DigiMax Eris FireStudio Nimbit PreSonus QMix Riff to Release Sceptre StudioLive and XMAX are trademarks or registered trademarks of PreSonus Audio Electronics Inc Capture Impact Mixverb Presence RedLightDist SampleOne Studio One and Tricomp are trademarks or registered trademarks of PreSonus Software Ltd Mac and Mac OS are registered trademarks of Apple Inc in the U S and other countries Windows is a registered trademark of Microsoft Inc in the U S and other countries Temporal EQ and TQ are trademarks of Fulcrum Acoustic Other product names mentioned herein may be trademarks of their respective companies All specifications subject to change without notice except the recipe which is a classic lo Station V2 fm a ge g go WW am m m tan m E om om fi 4 mam Him ne oe E PO ise MNAE wi t pm Wa f FS MK Aa WAN j y FS VW Ta ra Y LU A Lh E EN y O A J tt UWE ws a WU B She E as tes B B ar OO OO 1 9 0 MONITOR STATION v2 D
33. uick Start Guide will help get your Monitor Station V2 integrated with your system as quickly as possible These step by step instructions are based on a typical studio environment your setup will depend on your needs and applications Note Throughout this chapter we ll refer to turning a knob all the way down as zeroing the knob since for practical purposes the knob will be set to 0 2 1 1 Connecting the Monitor Station V2 s Power WARNING Before connecting the Monitor Station V2 s included power supply make sure that the power supply meets the input voltage requirements of the region or country in which you re using it PreSonus supports only the power supply shipped with your Monitor Station V2 If the power supply doesn t meet your local requirements or if you wish to purchase an additional power supply please contact your local dealer or distributor 1 Zero the Monitor Station V2 s front panel Main Output Level knob the Cue Output knob and the individual headphone Level knobs by turning them fully counterclockwise Note If you have speakers or other gear connected to the Main L R Line Outputs you should also zero their own output controls 2 Make sure the Monitor Station V2 s rear panel Power switch is turned off by pressing the 0 at the bottom of the switch 3 Connect the included power supply to the appropriate wall socket and the
34. uide Owner s Manual Digital audio device with S PDIF output Connect the source device s S PDIF output to the Monitor Station V2 s rear panel RCA coaxial S PDIF input The Monitor Station V2 supports sample rates of 44 1 48 88 2 and 96 kHz Note The RCA and 1 8 analog Aux In jacks are summed and can be used at the same time Control their volumes relative to each other using their individual output controls Switch between the analog Aux inputs and digital S PDIF inputs as described in Section 4 1 3 2 1 3 Calibrating the Monitor Station V2 s LED Meter By default the Monitor Station V2 s LED meters are calibrated so that the red 0 VU LED illuminates when the selected source signals reach 10 dBu This can be changed so that 0 VU references 4 10 or 18 dBu 4 dBu 0 VU should reference 4 dBu if any of your monitoring devices has a maximum input of 4 dBu or if none of your input devices has a maximum or nominal output level greater than 4 dBu Press and hold the Cue Source ST1 button while powering on your Monitor Station V2 10 dBu 0 VU should reference 10 dBu if any of your monitoring devices has a maximum input of 10 dBu or if none of your input devices has a maximum or nominal output level greater than 10 dBu Press and hold the Cue Source ST2 button while powering on your Monitor Station V2 18 dBu 0 VU should reference 18 dBu if any of your monitoring devices has a maximum input of 18 dBu or i

Download Pdf Manuals

image

Related Search

Related Contents

Harbor Freight Tools 45707 Grinder User Manual    Rear Discharge Lawn Tractor  User manual  User Guide SUSIAccess Signage  EL60-Z-W88 V1说明书  Multimetter FSM 500  Ariston 28 MFFI Boiler User Manual  Minka Lavery 4753-206 Installation Guide  Lexmark 18C1530E ink cartridge  

Copyright © All rights reserved.
Failed to retrieve file