Home

Service Manual

image

Contents

1. 2 Remove the red lift motor lead from the lift motor capacitor but leave the remaining red wire connected to the terminal 3 Remove the black lift motor lead from the lift motor capacitor but leave the remaining black wire connected to the terminal 4 Disconnect the connector on the white lift motor lead Note Do not disconnect J3 from the lower PCA The connector disconnected in the previous step connects the white lift motor lead to J3 5 Disconnect the molex connector on the rotation sensor wire assembly from connector J2 on the lower PCA Note When the rotation sensor wire assembly is disconnected from the lower PCA the zero sense switch must be disconnected as well 6 Disconnect the two blue wires on the rotation sensor wire assembly from the zero sense switch terminals 7 Place the treadmill on its left side 8 Remove the two shoulder screws and nuts that secure the lift motor to the treadmill frame see Diagram 6 3 Remove the lift motor and set it aside 9 Remove the set screw that secures the magnet hub to the lift motor Set aside the magnet hub Page 36 9 45 9 45i Treadmill Diagram 6 3 Lift Motor Components 1Y Units Lift Motor Lo i TP Rotation Sensor V SS Bracket amp Magnet w Rotation Sensor Hub G 10 Choose one If Then Otherwise You are replacing the Continue with the next Skip to Step 14 magnet step Removing and Replacing the M
2. 2 Remove the black and red wires from the lift motor capacitor terminals 3 Loosen the screw and nut on the capacitor mounting bracket 4 Remove the capacitor from the mounting bracket Replacing the Lift Motor Capacitor 5 Position the lift motor capacitor in the capacitor mounting bracket Note Wire length and wire assembly configuration may limit the mounting orientations of the lift motor capacitor Make sure that the wires you removed from the capacitor will reach the capacitor terminals before you perform the next step 6 Tighten the screw and nut on the capacitor mounting bracket 7 Connect the wires removed in Step 2 to the capacitor terminals Note Because the lift motor capacitor is not polarized you can connect wires to either terminal However you cannot mix wire colors on any one terminal 8 Check the operation of the treadmill as described in Section Three of this appendix then replace the hood as Page 44 9 45 9 45i Treadmill Procedure 6 6 Replacing the Transformer 1L Units Removing the Transformer 1 Remove the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual 2 Disconnect the wires from the transformer terminals listed in Table 6 2 Table 6 2 Transformer Connections WIRE TRANSFORMER TERMINAL Blue wire 10 Brown wire Blue wire Black wire Red wire Black wire Red wire N Q O OO 3 Remove the screws that secure the transformer to the treadmi
3. Treadmill Procedure 6 8 Replacing the Speed Sensor 2P amp 3Y Units WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Removing the Speed Sensor 1 Remove the hood 2 Disconnect the speed sensor wire assembly from the lower PCA 3 Remove the screw that secures the speed sensor to the sensor mounting bracket 4 Remove the speed sensor from the mounting bracket Replacing the Speed Sensor 5 Position the speed sensor in the sensor mounting bracket 6 Replace the screw that secures the speed sensor to the sensor mounting bracket see Diagram 6 6 Diagram 6 6 Speed Sensor Mounting 2P amp 3Y Units Flywheel Target PIRE Speed Sensor Speed Sensor Bracket Motor Page 48 9 45 9 45i Treadmill Connect the speed sensor wire assembly to the lower PCA Inspect and adjust the gap between the speed sensor and flywheel as described in Procedure 3 4 of the Residential Treadmill Service Manual Check the operation of the treadmill as described in Section Three of this appendix then replace the hood Page 49 9 45 9 45i Treadmill Procedure 6 9 Replacing the Lift Platform Removing the Lift Platform 1 Turn off the treadmill with the circuit breaker then unplug the power cord from the wall outlet WARNING Before continuing with this procedure review the Warning and Caution statements listed in Section One of the Residential Treadmill Servic
4. Using an ohmmeter measure the fuse resistance The fuse should measure approximately 1Q or less If the fuse is open eo or significantly higher than 1Q replace the fuse If the fuse was bad perform the test in step 4 before applying power to the lift If the fuse was good continue with step 5 Using an ohmmeter measure the resistance across the lift capacitor terminals The Lower PCA resistance should be extremely high megohms the capacitor resistance should be extremely high megohms and the lift motor winding should read approximately 34Q 120 Vac units or 122Q 240 Vac units Therefore if the measurement is significantly lower than 340 or 1220 disconnect both red leads from the lift capacitor Measure the resistance between the black leads on the lift capacitor and red lead to the lower PCA If it measures significantly low replace the lower PCA Measure the resistance between the black leads on the lift capacitor and red lead to the lift motor If it measures significantly low replace the lift motor Measure the resistance between the black leads on the lift capacitor and other terminal of the lift capacitor If it measures significantly low replace the lift capacitor At this point the lift fuse is good but there is no AC voltage on the lift capacitor when the lift is actuated There are three potential causes for this condition They are lower PCA ribbon cable or upper PCA There are no good means of troubleshooting these componen
5. Vdc or significantly low replace the lower PCA At this point the hall effect sensor and the zero sense switch are functioning normally but lift errors occur There are three potential causes for this condition They are lower PCA ribbon cable or upper PCA There are no good means of troubleshooting these components other than substituting known good components Replace only one component at a time If the component that you replaced does not correct the problem replace the original component Try substituting the lower PCA first the ribbon cable second and the upper PCA third If you have performed all of the above procedures and have been unable to correct the problem call Precor Customer Support Page 28 9 45 9 45i Treadmill Procedure 5 4 Troubleshooting the Lift System 9 45 2P amp 3Y Units System Description The lift system is powered by a 120 Vac lift motor that uses two independent motors windings One motor winding operates the motor in an upward direction and the other motor winding operates the motor in a downward direction The motor contains a 10 KQ potentiometer driven by the motor that indicates lift position AC power to operate the lift motor is provided by a pair of triacs One triac provides power to the up winding of the lift motor and the other triac provides power to the down winding of the lift motor The triacs are controlled either manually or by software control from the upper PCA 1 Ift
6. input current at 3 MPH eith the treadmil unloaded and at 3 MPH with the treadmill loaded Be sure to note the weight of the user on the loaded current rreading e Measure and note the AC ripple voltage at the drive motor capacitor at 3 MPH with the treadmill loaded and unloaded Press the STOP key When the treadmill comes to a stop view the electronic console as the treadmill scans time speed distance and percent Press the INCLINE A key while viewing the electronic console Confirm that the running bed inclines and the incline display increments to twelve percent as the INCLINE A key is pressed Press the INCLINE W key while viewing the electronic console Confirm that the running bed returns to a level position and the incline display decrements to minus two percent as the INCLINE Y key is pressed Turn off the treadmill with the circuit breaker then unplug the treadmill from the wall outlet Page 16 9 45 9 45i Treadmill Procedure 4 1 Calibrating the Lift Limit Switches 9 45 1L WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood 1 If the treadmill is not already at zero percent incline press any key when the CALIBRATE LIFT PRESS ANY KEY prompt is displayed 2 Using the ruler measure the distance between the floor and the top of the front and back ends of the side rail see Diagram 4 1 Note The distance between the floor and the top of the front end of th
7. the hub is not near the hall effect sensor and approximately 0 VDC when the magnet is near the hall effect sensor If the voltage switches between 5 and 0 Vdc as the magnet passes the hall effect sensor continue with step 11 Page 27 10 9 45 9 45i Treadmill Measure the voltage between the red wire term 4 of J3 and the black wire term 1 of J3 The voltage should read a constant 5 Vdc If the voltage is 0 or significantly lower than 5 Vdc disconnect the rotation sensor connector from the lower PCA Measure the voltage between the red wire term 4 of J3 and the black wire term 1 of J3 on the lower PCA If the voltage is still 0 Vdc or significantly low replace the lower PCA If the voltage is now correct replace the hall effect sensor Note If possible set the lift in a position that does not operate the zero sense switch The zero sense switch may be operated by hand to perform the tests in step 11 11 12 At this point the hall effect sensor is functioning normally but lift errors occur With a DC voltmeter measure the voltage across the zero sense center switch It should measure approximately 0 Vdc when the switch is not operated and approximately 5 Vdc when the switch is operated If the operated voltage is 0 Vdc or significantly low remove both blue wires from the zero sense switch Measure the voltage between the two blue wires If the voltage is now correct replace the zero sense switch If the voltage is still O
8. to the limit switch terminals Choose one If Then Otherwise You are replacing more Continue with the next Skip to Step 38 than one limit switch step to replace the lower limit switch or skip to Step 35 to replace the zero sense switch Replacing the Lower Lift Limit Switch 31 32 33 34 Position the limit switch at its mounting location Replace the screws and washers that secure the limit switch to the switch bracket Connect the black wires disconnected in Step 6 to the limit switch terminals Choose one If Then Otherwise You are replacing the Continue with the next Skip to Step 38 zero sense switch step Replacing the Zero Sense Switch 35 36 37 38 39 Position the limit switch at its mounting location Replace the screws and washers that secure the limit switch to the switch bracket Connect the blue wires disconnected in Step 9 to the switch terminals Calibrate the lift assembly as described in Procedure 4 1 of this appendix Check the operation of the treadmill as described in Section Three of this appendix then replace the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual Page 43 9 45 9 45i Treadmill Procedure 6 5 Replacing the Lift Motor Capacitor 1L Units WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Removing the Lift Motor Capacitor 1 Remove the hood
9. 9 45 9 45i Treadmill 11 The last routine is the circuit breaker trip test This test checks the ability of the treadmill to trip the circuit breaker under software control If the STOP key is pressed and held the trip signal will be sent to the circuit breaker and the circuit will trip shutting off the treadmill If you do not wish to trip the circuit breaker press the ENTER key to exit the diagnostic program Diagram 2 1 Display Housing 9 45 1Y amp 2P USER I D WEIGHT AGE DISTANCE PROGRAM INCLINE TOTAL CALORIES Toa mist wear Ge HEARTRATE rea atrae hemos saty ke wtenretinuss ardstre ototrech moar vata BENET LS CASUSSEN FITHESS SCORE otstilden ae SMUT BATE ere and ue bei bes om ka mative depty t SMART RATE n DWS rwa poned ENTER gt esoe V A STOP Z A I L 4 QUICKSTART INCLINE CONTROL HOLD TO RESET SPEED CONTROL CAUTION Bascol of Safety Key under handiebarwhen attaching cipo cbthing Page 5 9 45 9 45i Treadmill Procedure 2 2 Accessing the M9 45i 3Y Treadmill s Diagnostic Program Procedure 10 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker The diagnostic program provide six different routines to aid it testing and trouble diagnosis For the purpose of accessing the various software routines including the diagnostics program the display housing keys are hypothetically numbered 1 to 7 from left to right With the PRECOR M9 45
10. 9 45 9 45i Treadmill 9 45 9 45i Treadmill Warning This service manual is for use by Precor trained service providers only If you are not a Precor Trained Servicer you must not attempt to service any Precor Product Call your dealer for service This document contains information required to perform the majority of troubleshooting and replacement procedures required to repair and maintain this product This document contains general product information software diagnostic procedures when available preventative maintenance procedures inspection and adjustment procedures troubleshooting procedures replacement procedures and electrical block and wiring diagrams To move directly to a procedure click the appropriate procedure in the bookmark section to the left of this page You may drag the separator bar between this page and the bookmark section to change the size of the page being viewed 2003 Precor Incorporated Unauthorized Reproduction and Distribution Prohibited By Law Page 1 9 45 9 45i Treadmill Section One Things you Should Know About This Appendix Precor has re designed the M9 45 treadmill several times Units with the original design have serial numbers starting with 1L and were manufactured between January 24 1995 and March 25 1996 The M9 45 treadmill was then redesigned with serial numbers starting with 2P and were manufactured between March 26 1996 and November 15 1997 The 9 45i uses se
11. If the new part does not correct the problem replace the original part 6 Ifyou have performed all of the above tests and the lift system is still not functioning call Precor Technical Support 7 Set the treadmill circuit breaker in the off position Remove the F2 2 amp slow blow fuse from the lower PCA Measure the fuse with an ohmmeter The measurement should be 19 or less If the fuse is good re insert the fuse and skip to step 9 If the fuse is open or significantly high replace the fuse Before operating the lift motor it is necessary to perform a continuity test on the lift motor Page 29 10 11 12 13 9 45 9 45i Treadmill Remove the P2 connector from the lower board Using an ohmmeter measure between terminals 1 and 3 of P2 between terminals 1 and 2 of P2 and between terminals 2 and 3 of P2 The measurements should be approximately 14 59 14 50 and 29Q respectively If any of the measurements are significantly low replace the lift motor Measure resistance between term inal 1 of P3 and frame ground The reading should be open or no less than 10 megohms If the measurement is significantly low replace the lift motor Re insert the P2 connector in the lower PCA Set the treadmill circuit breaker in the on position Using an AC voltmeter monitor the voltage between terminals 1 and 2 white and red wires of the P2 connector Enter the manual program and press the INCLINE key The measureme
12. Ribbon C able Page 55 9 45 9 45i Treadmill Block Diagram 7 2 9 45 1L Units z yeuluuey 0 BUILLUA YOS 104 49S q 1snuu sioduunl Zdf S bdf eu s yOd Jeddn Jeu JO 9OL YIM stoe 8 SCDE UO L din ON yg yg 30A 06 VAAAST y 3 18 Ya Josuas J8 p ds M IPAG Moi 649 a dn ya peu ZW SOUdIMS UMOC H7 uaap Lu su s oJez O 7a HI uondu s q 10109 bBisag Var A s poiq Bumu 44617 vod uonejoy zem ea ooi ES OVA WU Joo D L A E l EI Km u per yuu Jaddn aiqeo uoqqly punog 92 4Z pasn jou 02 81 uonsod VI L din Dees EI Zezsu ax SL zezsu axa Hi aujou oe DI Jonuoo JosyuoD I0Juoo ONJUOD een WOU zL Pn it gdis read p d yp avemyos umop UIT oL p z OL wol4 Ul01J OL Wwol4 oe YOS 6 Josuas pasds 8 ys ep ssoJo oe Z OA S uondii53s q uld suono uuoo lqe2 uoqqry llupe 11 YOS 0ZL rF969 0Z Z965 0ZL Pr6D 96 t g o Joud yng llluipe 11 0ZL ST 6 Page 56 9 45 9 45i Treadmill Wiring Diagram 7 3 9 45 2P amp 3Y Units Lower PCA Power Cord Circuit Breaker Ribbon Cable wle BKI g Ferrite Bead BK Speed Sensor Capacitor Upper PCA BK Drive Motor Page 57 9 45 9 45i Treadmill Block Diagram 7 4 9 45 2P amp 3Y Units Omg un KI Di UIT SL puno o KO Ionue YOS EL punog H e oloud LL punog OL o l p seu O19Z 6 OGA S 8 av w L OA S 9 umop d
13. Selecting United States Standard or Metric Units Selecting United States standard units causes data to be displayed in feet miles and pounds Metric data is displayed in meters kilometers and kilograms Procedure 1 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker 2 Choose one IF THEN You wish to verify the measurement Continue with the next step standard the treadmill is currently using before you change the standard You wish to change the measurement Skip to Step 5 standard the treadmill is using Checking the Measurement Standard 3 Press ENTER until the WEIGHT indicator light appears 4 Watch the number displayed in the left display window while you press the SPEED A key five or six times Note If the treadmill is using United States standard units the numbers in the left display window are displayed multiples of 5 such as 160 165 170 175 etc If the units are displayed in multiples of 2 or 3 the treadmill set for metric units Changing the Measurement Standard 5 Press and hold STOP to return the PRECOR M9 45 banner 6 On 9 45 1L or 2P units press the QUICK START and then the SPEED a key Hold both keys for 3 5 seconds then release On 9 45 3Y units press keys RESET 5 6 7 1 sequeniially Note On 9 45 1L or 2P units releasing the QUICK START key before the SPEED A key when you perform the next step may cause the selected measurement standard
14. able 5 2 Voltage Test Points Function Keys Pressed Place the positive At the display The voltmeter should voltmeter lead on enclosure press read between Pin 3 of J3 ENTER 0 Vdc and 500 mVdc Pin 4 of J3 INCLINE DOWN 0 Vdc and 500 mVdc Pin 5 of J3 INCLINE UP 0 Vdc and 500 mVdc Pin 7 of J3 STOP 0 Vdc and 500 mVdc Pin 8 of J3 SPEED DOWN 0 Vdc and 500 mVdc Pin 9 of J3 SPEED UP 0 Vdc and 500 mVdc Pin 10 of J3 QUICK START 0 Vdc and 500 mVdc If the voltage readings match those listed in Tables 5 1 and 5 2 and one or more keys do not function replace the upper PCA If the voltage readings in Table 5 1 are incorrect disconnect the keypad cable from the key pad connector and repeat the voltage measuremnts in 5 1 If the voltage readings are now correct replace the display housing keypad If the voltage readings are still incorrect replace the upper PCA If the voltage readings in Table 5 1 are correct and one or more voltage readings in Table 5 2 are incorrect replace the display housing keypad Set the circuit breaker in the off position If necessary carefully re connect the keypad cable to the keypad connector Remove the ground lead of the wrist strap from the treadmill frame then remove the wrist strap from your arm Position the display enclosure on the display plate Install the screws that secure the display enclosure to the display plate Check the operation of the treadmill as described in Section Thre
15. agnet 11 Remove the set screw that secures the magnet to the magnet hub Discard the magnet Note When you position the magnet in the magnet hub place the north pole towards the center of the magnet hub The north pole of the magnet should be marked with a spot of white paint If the magnet on the treadmill you are servicing is not marked use either a compass or another magnet to determine the north pole 12 Position a new magnet in the magnet hub 13 Tighten the set screw that secures the magnet to the magnet hub Page 37 9 45 9 45i Treadmill 14 Choose one If Then Otherwise You are replacing the Continue with the next Skip to Step 18 rotation sensor step 15 Remove the screw and washer that secure the rotation sensor to the sensor bracket see Diagram 6 3 16 Position the rotation sensor at its mounting location 17 Position the screw and washer that secure the rotation sensor to the sensor bracket Torque the screw to 8 in lbs 18 Choose one If Then Otherwise You are replacing the lift Continue with the next Skip to Step 22 motor you removed step earlier in this procedure Removing and Replacing the Rotation Sensor Bracket 19 Remove the two nuts that secure the sensor bracket to the lift motor 20 Position the sensor bracket removed in the previous step on the lift motor 21 Replace the two nuts that secure the sensor bracket to the lift motor Replacing the Lift Motor 22 Position the m
16. agnet hub on the lift motor so that it is flush with the speed sensor bracket 23 Replace the set screw that secures the magnet hub to the lift motor 24 Extend the lift motor actuator 1 2 by turning the magnet hub Note To extend the lift motor actuator faster place a screwdriver shaft in the lower mounting hole of the lift motor and turn the screwdriver handle 25 Position the lift motor at its mounting location Note When you perform Step 26 replace the lower screw and nut first 26 Replace the two shoulder screws and nuts that secure the lift motor to the treadmill frame Page 38 9 45 9 45i Treadmill Note The original nuts used to mount the lift motor are Kep nuts which do not require a separate washer If you do not use Kep nuts to mount the lift motor use washers when you mount the lift motor to the treadmill frame 27 28 29 30 31 32 33 34 Return the treadmill to an upright position Connect the black lift motor lead to the terminal of the lift motor capacitor that already has a black wire Connect the red lift motor lead to the terminal of the lift motor capacitor that already has a red wire Connect the connector on the white lift motor lead that connects the lift motor to pin 4 of lower PCA connector J3 Connect the molex connector on the rotation sensor wire assembly to connector J2 on the lower PCA Connect the two blue wires on the rotation sensor wire assembly to the term
17. ate information displayed is correct THEN OTHERWISE The Smart Rate system is operating Continue with the next step correctly There is no need to continue with this procedure Re adjust the fit of the chest strap If the HEART RATE indicator still does not blink as described in Step 4 If the chest strap transmitter has a replaceable battery replace the battery If the HEART RATE indicator still does not blink as described in Step 5 THEN OTHERWISE Continue with the next step The Smart Rate system is operating correctly There is no need to continue with this procedure Hold the Heart Rate Test Transmitter Precor part number 20045 101 near the display housing If the HEART RATE indicator on the electronic console blinks with the LED on the Smart Rate Test Generator THEN OTHERWISE The chest strap assembly is bad The heart rate receiver assembly is Wear a new chest strap assembly bad Replace the heart rate receiver as when you use the Smart Rate described in Procedure 5 4 of the System Residential Treadmill Service Manual Press ENTER to return to the User ID Page 25 9 45 9 45i Treadmill Procedure 5 3 Troubleshooting the Lift System 9 45 1L Units Lift System Description The lift system on these units consists of an AC line voltage driven lift motor 120 Vac or 240 Vac a hall effect rotation sensor and three position location switches The lift system orients itself by locating the
18. aved user information will be either reset to zero or changed to default values All odometers will be reset to zero If you want to save accumulated user information and odometer readings record the information before performing this procedure Note This procedure is not available on the 9 45i User stats must be reset individually per Procedure 2 4 Procedure 1 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker 2 With the PRECOR M9 45 or PRECOR Ma Abt banner scrolling press the INCLINE a INCLINE v SPEED A and SPEED wkeys simultaneously and hold them for approximately five seconds or until zeros are displayed in the right display windows Release the keys 3 Watch the electronic display The right middle display window a b C d e Note Resets to all zeros then increments to 119 Resets to 1000 then increments to 1119 Resets to 2000 then increments to 2119 Resets to 3000 then increments to 3119 Displays the User ID prompt If the upper PCA or prom is replaced all user information will be re initialized Page 8 9 45 9 45i Treadmill Procedure 2 4 Resetting an Individual User s Information This procedure resets accumulated user information and odometer readings for an individual User ID All previously saved user information for a selected User ID will be either reset to zero or changed to default values The odometer reading for the selected User ID w
19. banner scrolling press keys RESET 5 1 7 6 5 7 6 1 sequentially See Diagram 2 2 The first routine is the LED display test The routine will light every LED on the display as the test proceeds It is necessary to watch the display to see if an LED does not light The second routine is lift calibration The lift calibration number indicates the physical position of the lift As lift is operated the lift calibration number will track the lifts physical position The lift calibration number will be used to initialize the lift Press the INCLINE keys while you watch the right display window see Diagram 2 2 The lift calibration number increments as the INCLINE A key is pressed and decrements as the INCLINE Y key is pressed Press ENTER to continue The third routine is the power bits display Power bits is a number that indicates the amount of time that power is applied to the drive motor duty cycle The power bit number reflects changes in speed and load Power bits and running belt speed will be displayed Notice that the power bits number will increase or decrease as speed and or load is increased or decreased The power bit number can be used to determine treadmill loading Press ENTER to continue The fourth routine is the key pad test Seven dashed lines will appear on the display Each dash will correspond to a key on the display Press each key one at a time the corresponding dash will enlargen indicating the key that was pressed Use
20. d all anti static precautions must be followed during this procedure Remove the printed circuit assembly per its associated procedure Currently we are using two styles of IC software packages they are a 28 pin dual in line package DIP28 and a forty four pin square package PLCC44 Each of these packages should be removed with a r IC removal tool see the illustrators below PLCC44 removal tool DIP28 removal tool The IC s may inserted into their socket by hand by carefully aligning the notch on the IC with the notch on the IC socket and carefully pressing the IC into its socket See the illustrations below for the alignment notches Care must be taken that the IC legs on a DIP28 are all aligned in the socket to prevent the legs from bending when inserted The PLCC44 IC must be carefully aligned squarely in its socket or it will not insert Do not force the IC into its socket If it does not insert easily remove the it and re align it in its socket wha EE E EN Cas V4 02 LWR B Q 32 00 SC PCA Page 54 9 45 9 45i Treadmill Wiring Diagram 7 1 9 45 1L Unit Rotation Sensor Up Limit Switch W S Lift Capacitor R R Lift Motor R Zero Sense Switch GC Down Limit Switch BL BL BK ny BK DAR L Transformer 361 42 4413 4 O 5 P2 P3 2 BR Ea P4 4 A B 6 5 BK R p1 6 1 7 Y 4 Je 8 G 3 1 d d F AC2 m 2 amp ACK 3 Speed Sensor R 1 Ps 8 e d Ca me Ma Lower PCA EON j
21. e refer to local electrical codes when determining the appropriate wire size for a 20 amp circuit 2 Both the hot leads feed several A C outlets Both hot leads must be removed from treadmill s A C outlet and two new hot leads from the treadmill s A C outlet to the circuit breaker must be added A licensed electrician may use the followings hints to determine if an A C service is dedicated 1 If ona 120 Vac system the A C distribution panel contains more circuit breakers than neutral leads the system has shared neutral leads and is not dedicated 2 Ifan A C outlet 120 or 240 Vac has multiple hot and or neutral leads it is not a dedicated If either of the above conditions exist the system is not dedicated However absence of the above conditions does not necessarily mean that the system is dedicated If any doubt exists about A C systems dedication point to point tracing of the A C wiring may be the only way to prove system dedication Page 32 9 45 9 45i Treadmill Procedure 6 1 Replacing the SCR 1L Units Diagrams 6 1 and 6 2 illustrate the components underneath the hood Removing the SCR 1 Remove the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual 2 Disconnect the wires from the SCR terminals listed in Table 945 4 Table 6 1 SCR Electrical Connections WIRE SCR TERMINAL Black wire Red wire Blue wires G1 and G2 Brown wire AC1 Blue wire AC2 3 Rem
22. e Manual 2 Place the treadmill on its left side Note To avoid scratching or marring the treadmill put a drop cloth underneath the treadmill when you perform Step 2 3 Remove the lower bolt and nut that secure the lift motor to the lift platform Note It is not necessary to remove the lift motor when you remove the lift platform 4 on1Lunits only remove the bolt that connects the actuator block to the lift platform 5 Remove the bolts and nuts that secure the lift platform to the treadmill frame see Diagram 6 7 Page 50 9 45 9 45i Treadmill Diagram 6 7 Lift Platform Lift Motor 1L Units Only Lift Platform Replacing the Lift Platform 6 With the treadmill still on its left side position the lift platform at its mounting position 7 Replace the two bolts and nuts that secure the lift platform to the treadmill frame Note The original nuts used to mount the lift platform are Kep nuts which do not require a separate washer If you do not use Kep nuts to mount the lift platform use washers when you mount the lift platform to the treadmill frame 8 On 1L units replace the bolt that connects the actuator block to the lift platform 9 Replace the lower bolt and nut that secure the lift motor to the treadmill frame 10 Check the operation of the treadmill as described in Section Three of this appendix then replace the hood Page 51 9 45 9 45i Treadmill Procedure 6 10 Replacing the Tar
23. e of this appendix Page 23 9 45 9 45i Treadmill Procedure 5 2 Troubleshooting the Heart Rate System If the HEART RATE indicator does not blink with your heart beat when you perform Procedure 2 1 the problem may be either the heart rate receiver assembly or the chest strap assembly This troubleshooting procedure gives you the information you need to determine which of these components is malfunctioning Procedure 1 If you are referring to this procedure because the HEART RATE indicator did not blink properly when you performed Procedure 2 1 step 10 THEN OTHERWISE Skip to Step 7 Continue with the next step 2 Check the mounting orientation of the Polar heart rate receiver It must be mounted and oriented as shown in diagram 5 2 Diagram 5 2 Polar Heart Rate Receiver Orientation Receiver Side View Receiver Page 24 8 9 45 9 45i Treadmill Plug the power cord into the wall outlet then turn on the treadmill with the ON OFF switch If necessary use conductive spray Precor part number 37364 101 to ensure good contact between the chest strap transmitter and the user put on the heart rate chest strap transmitter Enter the diagnostics program per Procedure 2 1 or 2 2 Proceed to the heart rate test portion of the diagnostics program HArt will be displayed in the right display window when the heart rate routine is accessed If the HEART RATE indicator blinks with your heart beat and the heart r
24. e side rail should be 9 inches Diagram 4 1 Treadmill Side Rail Measurement Page 17 9 45 9 45i Treadmill 3 Ifthe distances recorded in the previous step are equal to within 1 4 THEN OTHERWISE Skip to Step 17 Continue with the next step 4 Atthe PRESS ENTER FOR PROGRANMS prompt press and hold the ENTER key 5 Press ENTER when the display test starts 6 With the ADJUST LIFT YESIDN NO UP prompt displayed press any Y key The message PRESS ENTER WHEN FINISHED is displayed on the electronic console 7 If the distance measured at the front of the side rail is larger than the distance measured at the back of the side rail THEN OTHERWISE Press the INCLINE YV key until Press the INCLINE key until the the front and back treadmill front and back treadmill measurements measurements are equal then are equal then press RESET press RESET 8 Turn off the treadmill with the circuit breaker then unplug the power cord from the wall outlet WARNING Before continuing with this procedure review the Warning and Caution statements listed in Section One of the Residential Treadmill Service Manual 9 10 11 Remove the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual Check the position of the zero sense switch in relation to the switch actuator see Diagram 4 2 If the widest point of the switch actuator is lined up with the center of the wheel on the zero sense switc
25. e top display window shows the most significant bits of the number the lower display window shows the least significant bits of the number The number displayed is 102 187 723 in miles or kilometers Diagram 2 3 Odometer Reading For the Treadmill 3 Press ENTER to access the error code log Page 10 9 45 9 45i Treadmill 4 There are five error code log positions The error code log is displayed and scrolls across the left display window see Diagram 2 4 Use the SPEED v or INCLINE v and SPEED A or INCLINE A keys to scroll through the error code log The most recent error condition will be displayed in position 1 and the oldest error will be displayed in position 5 When an error is added to a full log the new error will be inserted in position 1 and all other logs will be pushed down one position The error that was in position 5 will be lost 5 Once you have completed the diagnosis and repair of the treadmill it is generally desirable to clear the error code log Then any subsequent error that are logged will be known to be new error conditions To clear the error code log press the QUICK START and STOP keys simultaneously Or press ENTER to retain the current error information and return to the User ID prompt Diagram 2 4 Error Code Log N 22 Er 1 6 The example above Diagram 2 4 shows an Error 22 in position 1 and No Error in position 2 Page 11 9 45 9 45i Treadmill Procedure 2 6
26. e treadmill frame Note Place a drop cloth under the treadmill to protect the flooring and to ensure that the treadmill handrails are not scratched or damaged 4 Place the treadmill on its right side 5 Remove the bolt and nut that holds the top of the lift motor to the treadmill frame 6 Remove the bolt and nut that secure the lift tube to the lift platform Set aside the lift motor Replacing the Lift Motor 7 With the treadmill still on its side line up the mounting holes at the top of the lift motor with the lift motor mounting holes on the treadmill frame 8 While an assistant holds the lift motor in place position the bolt through the top of the lift motor and the treadmill frame Thread the nut onto the bolt 9 Calibrate the lift assembly as described in Section Four of this appendix 10 Replace the bolt and nut that secure the lift tube to the lift platform 11 Return the treadmill to an upright position 12 Secure the ground wire to the lift motor ground stud on the treadmill frame 13 Connect the lift motor wiring assembly to the lower PCA 14 Check the operation of the treadmill as described in Section Three of this appendix then replace the hood Page 53 9 45 9 45i Treadmill Procedure 6 12 Replacing the PROM Anti static kits part number 20024 101 can be ordered from Precor 1 The PROM and the associated printed circuit assembly PCA are static sensitive Anti static devices must be used an
27. emove the screws and washers that secure the limit switch to the switch bracket see Diagram 6 4 8 If you are not removing the zero sense switch skip to step 12 Removing the Zero Sense Switch 9 Carefully remove the blue wires from the zero sense switch Page 40 9 45 9 45i Treadmill Diagram 6 4 Limit Switch Mounting 1Y Units Lower Limit Switch Zero Sense Switch Switch Bracket Upper Limit Switch Switch Actuator Lift Capacitor Actuator Shaft 10 Remove the two screws and washers that secure the limit switch to the switch bracket See Diagram 6 4 11 If you are not removing the actuator shaft skip to step 17 Removing the Actuator Shaft and Switch Actuator 12 Remove the screw that secures the switch actuator to the actuator shaft Set aside the screw and switch actuator 13 Remove the shoulder screw that connects the actuator shaft and actuator block to the lift platform Note If necessary hold the actuator shaft with the pliers and support the actuator block firmly with your hand when you perform Step 14 14 Unscrew the actuator shaft from the actuator block Set aside the actuator block 15 Slide the actuator shaft from the switch bracket 16 If you are not removing the switch bracket skip to step 20 Page 41 9 45 9 45i Treadmill Removing and Replacing the Switch Bracket 17 Remove the socket head screws and washers that secure the switch bracket to the lift motor
28. fed by a 20 amp circuit breaker that feeds a single load A treadmill operating from a non dedicated circuit or a circuit breaker of less than 20 amps capacity will not have the necessary power available to operate normally under higher load conditions The lack of available power can cause any number of symptoms ranging from numerous intermittent seemingly inexplicable error conditions poor speed control or tripping the house circuit breaker H any of the above symptoms exist the external A C circuit must be checked and confirmed to be a 20 amp dedicated circuit before troubleshooting the treadmill In addition the A C voltage must be checked Nominal A C operating voltage on 120 Vac circuits is 105 Vac to 120 Vac Nominal A C operating voltage on 240 Vac circuits is 208 Vac to 240 Vac For operator safety considerations and to minimize electrostatic discharge conditions the A C frame ground continuity must also be verified to be a low resistance connection to the A C distribution ground bar Important If the A C circuit feeding a treadmill is found to be a non dedicated circuit or a circuit equipped with a circuit breaker with a capacity of less than 20 amps the A C circuit must be corrected to be a 20 amp dedicated circuit before any reliable troubleshooting can be performed on the treadmill More importantly a non dedicated circuit may constitute a safety hazard to the treadmill operator 120 Vac Systems 120 Vac distribut
29. get Label 2P amp 3Y Units WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Removing the Target Label 1 Remove the hood CAUTION The speed sensor is mounted on the motor casing Exercise caution when you remove and replace the flywheel 2 Remove the flywheel as described in Procedure 5 17 of the Residential Treadmill Service Manual Remove the target from the flywheel Remove as much of the old adhesive as possible from the flywheel Ensure that any remaining adhesive is firmly bonded to the mounting location Clean the end of the flywheel with a mild detergent Remove the detergent with a damp cloth Replacing the Target Label 5 Remove the protective label from the adhesive side of the target label Carefully position the target on the flywheel then press the target firmly Replace the flywheel as described in Procedure 5 17 of the Residential Treadmill Service Manual Check the operation of the treadmill as described in Section Three of this appendix then replace the hood Page 52 9 45 9 45i Treadmill Procedure 6 11 Replacing the Lift Motor 2P amp 3Y Units WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Removing the Lift Motor 1 Remove the hood 2 Disconnect the lift motor wiring assembly from the lower PCA 3 Remove the ground wire from the lift motor ground stud on th
30. h THEN OTHERWISE The zero sense switch is calibrated The switch bracket must be adjusted correctly skip to Step 16 continue with the next step Page 18 9 45 9 45i Treadmill Diagram 4 2 Switch Mounting Bracket Assembly Lower Limit Switch Zero Switch Actuator Upper Limit Switch Lift Capacitor Page 19 9 45 9 45i Treadmill WARNING When power is applied to the treadmill the wires connected to the upper and lower limit switches carry 120 volts or 240 volts if you are servicing a 240 volt treadmill Turn off the treadmill and unplug the power cord from the wall outlet before you perform the following steps 12 Loosen the socket head bolts and washers that secure the switch bracket to the lift platform see Diagram 4 2 Note The zero sense switch may be actuated if the center of the wheel is slightly above or slightly below the widest point of the switch actuator However for best results adjust the position of the zero sense switch as described in the following step 13 Ifthe center ofthe wheel on the zero sense switch is above the widest point of the switch actuator THEN OTHERWISE Move the switch bracket down until Move the switch bracket up until the the widest part of the actuator is widest part of the actuator is centered centered on the wheel on the zero on the wheel on the zero sense switch sense switch then continue with then continue with the next step the next s
31. he lift tube against the motor frame 6 7 Press the INCLINE A or INCLINE Y keys to set the lift calibration number to 19 Press and hold STOP to get back to the Enter Your Weight banner Turn off the treadmill with the circuit breaker then unplug the treadmill from the wall outlet Turn the lift tube clockwise by hand as far as possible Then turn the lifttube 10 1 2 turns 1 1 2 counterclockwise Replace the screw and nut that secure the lift tube to the lift platform Return the treadmill to an upright position Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker Check the calibration of the lift system by performing the following steps a Press the INCLINE A key until the electronic console displays twelve percent incline b Use the INCLINE Y key to return the treadmill to zero percent incline Using the ruler measure the distance between the floor and the top of the front and back ends of the side rail The distance between the floor and the top of the front end of the side rail should be equal Re install the hood Page 21 9 45 9 45i Treadmill Procedure 5 1 Troubleshooting the Keypad and Upper PCA If the function keys on the electronic console are unresponsive the problem may be either the upper PCA or keypad This troubleshooting procedure gives you the information you need to determine which of these components is malfunctioning Procedure 1 Set the circ
32. he lift motor will not move skip to step 7 If the lift motor moves and an error occurs continue with step 2 2 Access the diagnostics program per Procedure 2 1 or 2 2 and proceed to the lift calibration portion of the diagnostics program If the lift calibration number is 0 or 255 skip to step 3 Operate the lift if the lift calibration number does not increment as the lift moves skip to step 3 If the calibration number increments as the lift moves recalibrate the lift per Procedure 4 2 If recalibration does not correct the problem continue with step 3 3 Set the treadmill circuit breaker in the off position Using an ohmmeter measure between terminal 4 brown wire and terminal 6 orange wire of the P2 connector on the lower PCA The measurement should be approximately 10 KQ If the measurement is open e or significantly high or low replace the lift motor 4 Using an ohmmeter measure between terminals 4 and 5 of P2 and measure between 5 and 6 of P2 on the lower PCA The two measurements should total approximately 10 KQ If the measurement is open co or significantly high or low replace the lift motor 5 If you have performed all of the above tests and an error still occurs when the lift motor operates there are three parts that could cause the problem There are not any good tests to check these parts other than substituting a known good part They are lower PCA ribbon cable and upper PCA Replace only one part at a time
33. hen it is necessary to isolate a problem to a particular component Section Six Replacement Procedures When a treadmill component must be replaced go to this section and follow the step by step procedures required to remove and replace the component Section Seven Wiring and Block Diagrams This section includes wiring and block diagrams for all versions of the 9 45 General Information For the latest exploded view part number and part pricing information visit the Precor dealer website at www precor com Dealer Page 2 Technical Specifications Physical Specifications Length Width Height Running surface Motor Speed Incline Power Weight Shipping weight About The Smart Rate System 9 45 9 45i Treadmill 71 inches or 180 cm Extended deck treadmills are 5 inches longer Handrails 31 5 inches 80 cm Base 28 5 inches 72 cm 50 inches 127 cm 53 inches by 18 inches 135 cm by 46 cm 2 hp continuous duty 0 5 to 10 mph 0 8 to 16 kph 10 mph is equivalent to a 6 minute mile 2 to 12 grade 50 60 Hz 120v AC dedicated circuit 50 60 Hz 240v AC dedicated circuit 265 Ibs 119 kg 326 Ibs 147 kg The Smart Rate system is the heart rate system mounted in the display housing The Smart Rate system receives a heart rate signal from chest strap transmitter worn by the user Smart Rate software displays a heart range on green red and yellow LED s mounted on the upper PCA The LED s indica
34. ill be reset to zero Procedure 1 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker 2 With the PRECOR M9 45 or PRECOR M9 45i banner scrolling press any key 3 Atthe User ID prompt select the User IDs to be reset using the SPEED A or INCLINE A and SPEED v or INCLINE v keys 4 Press the STOP and QUICKSTART keys together and hold them for approximately two seconds or until the right middle display window displays one of the numbers sets in Procedure 2 2 step 3a 3b 3c or 3d 5 If you do not observe the values listed in Procedure 2 2 step 3a 3b 3c or 3d THEN OTHERWISE Replace the upper PCA as described in This procedure is complete Procedure 5 2 of the Residential Treadmill Service Manual Note If the upper PCA is replaced all user information will be re initialized Page 9 9 45 9 45i Treadmill Procedure 2 5 Displaying the Treadmill Odometer and Error Code Log Procedure 1 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker 2 On9 45 1L or 2P units with the PRECOR M9 45 banner scrolling press the ENTER SPEED wand SPEED a keys simultaneously Continue to hold the keys until the message TREADMILL ODOMETER scrolls across the left display window On 9 45 3Y units press keys RESET 6 5 sequentially Note The right display window displays total miles or kilometers on the treadmill see Diagram 2 3 Th
35. inals on the zero sense switch terminals Calibrate the treadmill lift assembly as described in Procedure 4 1 of this appendix Check the operation of the treadmill as described in Section Three of this appendix then replace the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual Page 39 9 45 9 45i Treadmill Procedure 6 4 Replacing the Limit Switches Actuator Shaft or Switch Bracket 1L Units The three limit switches and the actuator shaft are mounted on the switch bracket see Diagram 6 4 WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Procedure 1 Remove the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual 2 Ifyou are not removing the upper limit switch skip to step 6 Removing the Upper Limit Switch WARNING When power is applied to the treadmill the wires connected to the upper and lower limit switches carry line voltage Turn off the treadmill and unplug the power cord from the wall outlet before you perform the following steps 3 Carefully remove the red wires from the upper limit switch Note See diagram 6 6 for limit switch wiring 4 Remove the screws and washers that secure the limit switch to the switch bracket 5 If you are not removing the lower limit switch skip to step 9 Removing the lower Limit Switch 6 Carefully remove the black wires from the down limit switch 7 R
36. ion systems utilize a single pole circuit breaker hot lead and a neutral lead connected to a common neutral ground bar The A C safety ground green wire is connected to a separate ground bar in the distribution system The most common problems found are 1 the circuit is fed by a circuit breaker of less than 20 amp capacity 2 the circuit breaker correctly feeds a single A C outlet but the neutral is common between several A C outlets and 3 both the hot and neutral leads feed several A C outlets The appropriate correction action or actions see below must be followed if any of the above conditions exist Corrective actions should only be undertaken by a licensed electrician 1 The circuit breaker feeding the treadmill is not a 20 amp circuit breaker If the circuit breaker is greater than 20 amps the circuit breaker should be replaced with a 20 amp circuit breaker If the circuit breaker is less than 20 amps the circuit breaker must be replaced with a 20 amp circuit breaker and the wiring from the A C distribution must be capable of safely handing 20 amps If the A C wiring is under sized it must be replaced with wire capable of safely handling 20 amps Please refer to local electrical codes when determining the appropriate wire size for a 20 amp circuit Page 31 9 45 9 45i Treadmill 2 The circuit breaker correctly feeds a single A C outlet but the neutral is common between several A C outlets The common neutral lead m
37. itches upper and lower limit do not come into play during normal operation If either switch is activated it means that the lift has moved beyond it s normal range of motion When either limit switch is activated power is removed from the lift motor Removing power from the lift motor protects the lift system from physical damage Caution All resistance measurements must be performed with power removed from the treadmill Performing resistance measurements with voltage applied may damage your ohmmeter Procedure 1 If the lift motor operates but creates a lift error error 40 41 or 43 go to step 8 If the lift motor will not move continue with step 2 2 Put the treadmill in a condition in which the lift motor is ready to be operated for example quick start into the manual program Using an AC voltmeter monitor the voltage across the lift capacitor and press one of the incline keys Approximately 1 4 times the AC input voltage should appear on the lift capacitor when an incline key is pressed Approximately 170 Vac on a 120 Vac unit or approximately 340 Vac on a 240 Vac unit The actual lift capacitor voltage will vary with the AC input voltage If AC line voltage or 1 4 times line voltage is on the lift capacitor go to step 6 If no AC voltage is on the lift capacitor continue with step 3 Page 26 9 45 9 45i Treadmill Setthe treadmill circuit breaker in the off position Remove the 2 amp lift fuse F2 from the lower PCA
38. ll frame 4 Remove the transformer from the treadmill frame Replacing the Transformer 5 Position the transformer at its mounting location 6 Tighten the screws that secure the transformer to the treadmill frame 7 Connect the wires listed in Table 6 2 to the transformer 8 Check the operation of the treadmill as described in Section Three of this appendix then replace the hood Page 45 9 45 9 45i Treadmill Procedure 6 7 Replacing the Speed Sensor 1L Units WARNING Always turn off the circuit breaker and unplug the treadmill before you begin maintenance operations Removing the Speed Sensor 1 Remove the hood 2 Disconnect the speed sensor wire assembly from the lower PCA 3 Remove the screw that secures the speed sensor to the sensor mounting bracket 4 Remove the speed sensor from the mounting bracket Diagram 6 5 Speed Sensor Mounting 1L Units Replacing the Speed Sensor 5 Position the speed sensor in the sensor mounting bracket 6 Replace the screw that secures the speed sensor to the sensor mounting bracket 7 Connect the speed sensor wire assembly to the lower PCA Page 46 9 45 9 45i Treadmill Inspect and adjust the gap between the speed sensor and flywheel as described in Procedure 3 4 of the Residential Service Manual Check the operation of the treadmill as described in Section Three in the appendix of the treadmill you are servicing then replace the hood Page 47 9 45 9 45i
39. n 11 G din J E 1q Pno p lq gua un dA S z p snun L uondii5s q uld uono uuoo2 IECH UO V d OCGA 06 punog O punols GZ punog r p snun 2 1Z OCAS oz OA S 6l OA S gL p snun ZL Idi seyeosg YNO EI anv yn SL Omg yun vl Omg yn l p snun zL umop dn y LL lqeu y ol lonuo5 YOS 6 ol ouq g 729 p Sepp O1BZ H p snun 9 4 uondii3s q uld suono5 uuoo lqeS uoqqis VOD yg L jou s Josu s p ds Illuipe 11 ISr 6 SZ 6 SZ 6 Z 6 96 0 r Joye pounjoesnuew gpg uoqqiy OVA OCL SOYOIMS z Iguluu O LI uuueu YOS 104 Jas Og JsNW Zdr 2 Ldr si duin vod 1 ddn ISt 6 9 GZ 6 Z payunow j out81 ase siet Up WOd1 34 uo palunouu SI 10suas p ds CC paul L S JoN H1 3Y JOUOD OJJUoO 101 U00 YMS p dS q Dees ege oL wod woog OL wold HOS ear Z JON Page 58
40. nt should be approximately 120 Vac line voltage If the voltage is present and the lift motor moves normally skip to step 10 The voltage will only be present until such time as an error occurs If line voltage is not present skip to step 11 If line voltage is measured but the motor does not move replace the lift motor Monitor terminals 1 and 3 white and black wires of P2 Enter the manual program and press the INCLINE v key The measurement should be approximately 120 Vac line voltage If the voltage is present and the lift motor moves normally skip to step 12 The voltage will only be present until such time as an error occurs If line voltage is measured but the motor does not move replace the lift motor If line voltage is not present in both steps 9 and 10 there are three parts that could cause the problem There are not any good tests to check these parts other than substituting a known good part They are lower PCA ribbon cable and upper PCA Replace only one part at a time If the new part does not correct the problem replace the original part If you have performed all of the above tests and the lift system is still not functioning call Precor Technical Support Page 30 9 45 9 45i Treadmill Procedure 5 5 Troubleshooting the External A C Power Source It is extremely important that any Precor treadmill be connected to and operated on a dedicated 20 amp A C circuit A 20 amp dedicated circuit is defined as a circuit
41. ove the screws that secure the SCR to the treadmill frame Diagram 6 1 Parts Illustrations 1Y Units Drive Motor Capacitor Lower PCA Inductor Page 33 9 45 9 45i Treadmill Replacing the SCR 4 Coat the mounting surface of the SCR with a thin coat of thermal compound Position the SCR at its mounting location The treadmill frame is used a a heat sink for the SCR Therefore it is critical that the SCR is in full contact with the frame Position the screws that secure the SCR to the treadmill frame Using the torque wrench torque each screw to 10 in lbs Connect the wires listed in Table 6 1 to the SCR terminals Check the operation of the treadmill as described in Section Three of this appendix then replace the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual Diagram 6 2 Parts Illustration 1Y Units Drive Motor Lift Motor Lower Limit Switch Zero Sense Switch Upper Limit Switch Lift Capacitor Page 34 9 45 9 45i Treadmill Procedure 6 2 Replacing the Terminal Block 1L Units WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Removing the Terminal Block 1 2 3 4 Remove the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual Remove the screws that secure the protective cover and terminal block to the treadmill Remove the stud that secures the blue
42. ow see Diagram 2 1 The lift calibration number increments as the INCLINE A key is pressed and decrements as the INCLINE Y key is pressed Press ENTER to continue The third routine is the power bits display Power bits is a number that indicates the amount of time that power is applied to the drive motor duty cycle The power bit number reflects changes in speed and load Power bits and running belt speed will be displayed Notice that the power bits number will increase or decrease as speed and or load is increased or decreased The power bit number can be used to determine treadmill loading Press ENTER to continue The fourth routine is the keypad test Seven dashed lines will appear on the display Each dash will correspond to a key on the display Press each key one at a time the corresponding dash will enlargen indicating the key that was pressed Use this test to determine if the keys are functioning properly Press the INCLINE v and SPEED A keys simultaneously to continue The fourth routine is the safety key test When the safety key is inserted SAFE ON is displayed in the right display window Remove the safety key from the upper display module while you watch the right display window SAFE OFF is displayed Replace the safety key and press ENTER to continue The fifth routine is the heart rate test When a chest strap transmitter or test transmitter is used the heart rate will be displayed Press ENTER to continue Page 4
43. platform Set aside the switch bracket 18 Position the switch bracket at its mounting location 19 Replace the socket head screws and washers that secure the switch bracket to the lift motor platform Replacing the Actuator Shaft and Switch Actuator 20 Slide the actuator shaft through the switch bracket until it is positioned at its mounting location 21 Thread the actuator block onto the lower end of the actuator shaft Note If necessary use the pliers to secure the actuator block to the actuator shaft 22 Position the shoulder screw removed in Step 13 through the actuator block and into the base of the lift platform 23 Tighten the shoulder screw that connects the actuator shaft and actuator block to the lift platform 24 Position the switch actuator on the top of the actuator shaft 25 Replace the screw that secures the switch actuator to the actuator shaft 26 Choose one If Then Otherwise You must replace one or Continue with the next Skip to Step 38 more of the limit switches step to replace the upper limit switch skip to Step 31 to replace the lower limit switch or skip to Step 35 to replace the zero sense switch Replacing the Upper Lift Limit Switch 27 Position the limit switch at its mounting location 28 Replace the screws and washers that secure the limit switch to the switch bracket Page 42 29 30 9 45 9 45i Treadmill Connect the red wires disconnected in Step 3
44. rial numbers starting with 3Y and started in production on November 16 1997 The 9 45i is the only version of the 9 45 that is currently in production This document will refer to the three versions as follows 9 45 1Y 9 45 2P and 9 45i 3Y Section One Things You Should Know This section includes general information and technical specifications Read this section as well as the M9 45 Treadmill Owner s Manual before you perform the maintenance procedures in this manual Section Two Software Features Precor s M9 45 Treadmill is programmed with several diagnostic and setup features This section contains the procedures you need to access the diagnostic features on this treadmill Section Three Checking Treadmill Operation This section provides you with a quick way of checking treadmill operation Check treadmill operation at the end of a maintenance procedure and when it is necessary to ensure that the treadmill is operating properly Section Four Inspection and Adjustment Procedures Perform inspection procedures when a trouble symptom points to a particular problem and after removing and replacing major components Many maintenance problems can be fixed by adjusting various treadmill components This section also provides you with the step by step procedures required to make these adjustments Section Five Troubleshooting Procedures The diagnostic and troubleshooting procedures contained in this section should be performed w
45. te whether the heart rate is below within or above the desired rang Page 3 9 45 9 45i Treadmill Procedure 2 1 Accessing the M9 45 1L or 2P Treadmill s Diagnostic Program Procedure 10 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker The diagnostic program provide six different routines to aid it testing and trouble diagnosis On 9 45 1Y amp 2P units with the PRECOR M9 45 banner scrolling press and hold ENTER until the software version number is displayed in the right display windows On units that have serial numbers starting with 2P the part number of the PROM will also be displayed The first routine is the LED display test The routine will light every LED on the display as the test proceeds It is necessary to watch the display to see if an LED does not light On 9 45 1L units the second routine is the lift test The lift test takes the lift through each of the critical lift positions In doing so it tests the performance of the zero switch upper limit switch lower limit switch and rotation sensor Press ENTER to continue On 9 45 2P units the second routine is lift calibration The lift calibration number indicates the physical position of the lift As lift is operated the lift calibration number will track the lift s physical position The lift calibration number will be used to initialize the lift Press the INCLINE keys while you watch the right display wind
46. tep 14 Tighten the socket head bolts and washers that secure the switch bracket to the lift platform see Diagram 4 2 15 Replace the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual 16 Check the operation of the treadmill as described in Section Three of this appendix IMPORTANT If the electronic console displays the diagnostic message LIFT ERROR PRESS STOP when you incline and decline the running bed to its maximum limits repeat this procedure If readjusting the position of the switch actuator does not fix the problem refer to Troubleshooting Flow Chart 13 of the Residential Treadmill Service Manual Page 20 9 45 9 45i Treadmill Procedure 4 2 Calibrating the Lift Motor 9 45 2P or 3Y Turn off the treadmill with the circuit breaker then unplug the treadmill from the wall outlet 2 Remove the hood 3 Place the treadmill on its right side Remove the bolt and nut that secure the lift tube to the lift platform 4 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker 5 Press and hold the STOP SPEED A SPEED Y and QUICK START keys simultameously or keys 4 5 1 7 6 5 7 6 1 sequentially until the lift calibration number is displayed on the console CAUTION While running the lift motor in the calibration mode it is possible to operate the lift motor beyond the motor s normal limits When you perform the next step care must be taken not to jam t
47. this test to determine if the keys are functioning properly Press the INCLINE v and SPEED v keys simultaneously to continue The fifth routine is the safety key test When the safety key is inserted SAFE ON is displayed in the right display window Remove the safety key from the upper display module while you watch the right display window SAFE OFF is displayed Replace the safety key and press ENTER to continue The sixth routine is the heart rate test When a chest strap transmitter or test transmitter is used the heart rate will be displayed Press ENTER to continue Page 6 9 45 9 45i Treadmill 11 The last routine is the circuit breaker trip test This test checks the ability of the treadmill to trip the circuit breaker under software control If the STOP key is pressed the trip signal will be sent to the circuit breaker and the circuit will trip shutting off the treadmill If you do not wish to trip the circuit breaker press the ENTER key to exit the diagnostic program Diagram 2 2 Display Housing 9 45i 3Y WD i Aer Pepe Tra Peco Piti Epi Cee Ram m i Kuu K amp Tim U Lienen Dee re ze Bebe ER m Pet ben br reg KW RW mert reen Je SHARAT RATE CTAA mn m mm a m wa mr maa ctr Total Calories Hiart Piata Fins Score Page 7 9 45 9 45i Treadmill Procedure 2 3 Resetting All User Information This procedure completely resets the M9 45 user statistics All previously s
48. tion Model and serial number Software version number Note Determine the version number as in Procedure 2 7 User and program number running when the problem occurred Adescription of a What happened or failed to happen b The action taken by the user just before the problem occurred c Problem related information such as how far into the program the problem occurred the work level being used when the problem occurred etc The frequency of occurrence Page 15 9 45 9 45i Treadmill Section Three Checking Treadmill Operation This section provides you with a quick method of checking treadmill operation Check treadmill operation at the end of a maintenance procedure and when it is necessary to ensure that the treadmill is operating properly Procedure 1 2 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker Place the treadmill in Manual Mode Adjust the speed of the running belt to 2 3 mph Operate the treadmill for at least 5 minutes a Concentrate on the feel of the running belt and the sound of the drive motor and rollers Be on the alert for unusual noises smells or vibrations b Measure and log the AC input current under loaded and unloaded conditions c Observe the LEDs on the electronic console Make sure that each LED lights as the information corresponding to that LED is displayed on the electronic console d Measure and note the AC
49. to change to the alternate Page 12 9 45 9 45i Treadmill measurement standardUse the SPEED A or SPEED v keys to select the alternate measurement standard 7 Press ENTER twice to return to the User ID prompt Page 13 9 45 9 45i Treadmill Procedure 2 7 Determining Software Version Numbers Software version numbers are invaluable for tracking and identifying problems and staying aware of changes to the operation and features of the product Procedure 1 Plug the power cord into the wall outlet then turn on the treadmill with the circuit breaker 2 On9 45 1L or 2P units with the PRECOR M9 45 banner scrolling press the ENTER key On 9 45 3Y units with the PRECOR M9 45 banner scrolling press keys RESET 5 1 7 6 5 7 6 1 sequentially 3 Note the version number displayed in the right middle display window Note If you cannot determine the software version number in this manner look at the label on the PROM mounted on the upper PCA The part number stamped on the PROM indicates the software version number Page 14 9 45 9 45i Treadmill Procedure 2 8 Documenting Software Problems When a problem is found with either the software or upper or lower PCA s record the information listed below If you isolated the problem to either the PROM upper PCA or lower PCA include the information you recorded with the malfunctioning PROM or PCA when you ship it to Precor When a problem occurs record the following informa
50. ts other than substituting known good components Replace only one component at a time If the component that you replaced does not correct the problem replace the original component Try substituting the lower PCA first the ribbon cable second and the upper PCA third If you have performed all of the above procedures and have been unable to correct the problem call Precor Customer Support Using an ohmmeter measure the resistance across the lift capacitor terminals The lower PCA resistance should be extremely high megohms the capacitor resistance should be extremely high megohms and the lift motor winding should read approximately 34Q or 1220 If it measures significantly high or open ceo replace the lift motor If the resistance measurement in step 6 was approximately 34Q 120 VAC units or 1220 240 VAC units replace the lift capacitor If you have performed all of the above procedures and have been unable to correct the problem call Precor Customer Support Typically when the lift is able to physically move but causes a lift error the problem is in the lift position identification system rotation sensor and zero sense switch Connect a DC voltmeter between the white wire term 2 of J3 and the red wire term 4 of J3 on the lower PCA Set the treadmill circuit breaker in the on position and slowly rotate the hub at the bottom of the lift motor by hand The DC voltmeter should read approximately 5 Vdc when the magnet in
51. uit breaker in the off position WARNING Before continuing with this procedure review the Warning and Caution statements listed in Section One of the Residential Treadmill Service Manual 2 Remove the screws that secure the upper display assembly to the upper handrail Carefully pull some excess interconnect cable out from the targa upright Rotate the display housing so that the rear of the upper PCA is facing upward and set the display housing on the upper handrail 3 Attach the wrist strap to your arm then connect the ground lead of the wrist strap to the treadmill frame Set the voltmeter to a range that will conveniently read 6 Vdc Diagram 5 1 Upper PCA Component Layout M 5 P S000 0000006 OO J2 r L OOOOQOOOOOOOOOO J1 25 1 4 Set the voltmeter to a range that will conveniently read 6 Vdc 5 Set the circuit breaker in the on position 6 Usea DVM set for DC volts and read between pin 6 of J3 and the each of the pins in Table 5 1 no keys pressed and Table 5 2 with the appropriate key pressed Page 22 9 45 9 45i Treadmill Table 5 1 Voltage Test Points Function Keys Not Pressed Place the positive lead of the The voltmeter should read voltmeter on Pin 3 of J3 5 Vdc 500 mVdc Pin 4 of J3 5 Vdc 500 mVdc Pin 5 of J3 5 Vdc 500 mVdc Pin 7 of J3 5 Vdc 500 mVdc Pin 8 of J3 5 Vdc 500 mVdc Pin 9 of J3 5 Vde 500 mVdc Pin 10 of J3 5 Vdc 500 mVdc T
52. ust be removed from treadmill s A C outlet and a new neutral lead from the treadmill s A C outlet to the A C neutral distribution bar must be added 3 Both the hot and neutral leads feed several A C outlets Both the common neutral and hot leads must be removed from treadmill s A C outlet and a new neutral lead and hot lead from the treadmill s A C outlet to the A C neutral distribution bar and circuit breaker must be added 240 Vac Systems 240 Vac distribution systems utilize a double pole circuit breaker two hot leads The A C safety ground green wire is connected to a ground bar in the distribution system The most common problems found are 1 the circuit is fed by a circuit breaker of less than 20 amp capacity and 2 both the hot leads feed several A C outlets The appropriate correction action or actions see below must be followed if any of the above conditions exist Corrective actions should only be undertaken by a licensed electrician 1 The circuit breaker feeding the treadmill is not a 20 amp circuit breaker If the circuit breaker is greater than 20 amps the circuit breaker should be replaced with a 20 amp circuit breaker If the circuit breaker is less than 20 amps the circuit breaker must be replaced with a 20 amp circuit breaker and the wiring from the A C distribution must be capable of safely handing 20 amps If the A C wiring is under sized it must be replaced with wire capable of safely handling 20 amps Pleas
53. wires to the terminal block Remove the stud that secures the brown wires to the terminal block Replacing the Terminal Block Note You can connect the wires to either terminal stud However you cannot mix brown and blue wires on any one stud see Wiring Diagram 7 1 or 7 3 Diagram 6 3 Terminal Block Wiring Connect the blue wires and the white wire blue wire if the treadmill you are servicing conforms to the European wire color code to the terminal block Connect the brown wires to the terminal block Position the protective cover over the terminal block then position the terminal block at its mounting location Mount the terminal block and protective cover to the treadmill frame with the two screws removed in Step 2 Check the operation of the treadmill as described in Section Three of this appendix then replace the hood as described in Procedure 5 1 of the Residential Treadmill Service Manual Page 35 9 45 9 45i Treadmill Procedure 6 3 Replacing the Lift Motor Rotation Sensor or Magnet Hub 1L Units Remove the magnet hub and rotation sensor bracket from the defective lift motor and mount them on the new lift motor Unless the magnet and or rotation sensor are defective do not remove them from their mounting positions on the magnet hub and sensor bracket WARNING Always turn off the circuit breaker and unplug the treadmill before you remove the treadmill hood Removing the Lift Motor 1 Remove the hood
54. zero sense switch when the treadmill is powered up When the zero sense switch is activated the system recognizes that physical position as 0 incline If the zero sense switch is activated when the treadmill is powered up the system proceeds directly into the normal program mode If the zero sense switch is not activated when the treadmill is powered up the system performs a self calibration procedure The purpose of the self calibration procedure is to locate the zero sense switch 0 incline The user will be prompted to press any key to commence the lift calibration The treadmill will go up 4 because the lowest the treadmill could have been at power up is 3 If the treadmill does not locate the zero sense switch by going up 4 it will stop and then go down until it activates the zero sense switch The system will then proceed to the normal program mode Once the 0 lift position has been located the system tracks any subsequent lift operations by counting motor revolutions A hall effect sensor is mounted on a bracket that is next to a hub that is attached to the lift motor shaft As the lift motors operates a magnet mounted in the hub passes the hall effect sensor once per motor revolution The hall effect sensor send one pulse to the lift control system per revolution The system knows how far the lift travels per revolution and by counting revolutions hall effect sensor pulses knows the current lift position The other two position sw

Download Pdf Manuals

image

Related Search

Related Contents

Moldy User`s Manual - Computational Chemistry List    Philips DLA66070D  DELL SCv2020  Population Environment DevelopmentAgriculture Model  C831 C832 C833 C835 C838  

Copyright © All rights reserved.