Home
B10320F: O2 / IV HOLDER ASSEMBLY AND
Contents
1. __ B10320F Oo IV HOLDER ASSEMBLY AND INSTALLATION Everest Jennings INSTRUCTIONS FOR EVEREST amp JENNINGS WHEELCHAIRS PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE Info The most current version of these instructions can be found online at www grahamfield com Tools required are listed at the beginning of each section Z WARNING Important Read and understand these instructions before installing or us ing the O2 IV Holder If you do not understand any part of these warnings cautions or instructions contact a healthcare professional for direction in the use of this product If the O2 IV Holder is not properly assembled and installed personal injury and dam age to the O2 IV Holder could result Z WARNING If components are damaged or missing contact your dealer immediately DO NOT use substitute parts Use only Everest amp Jennings replacement parts Non Everest amp Jennings replacement parts could cause personal injury and damage to the O2 IV Holder A WARNING GF Health Products Inc assumes no responsibility for any damage or in jury caused by improper assembly installation or use of this product HOLDER INSTALLATION ON WHEELCHAIR SEE ILLUSTRATIONS BELOW Remove O2 IV Holder from carton and protective packaging ower rail ower bracket lock washer lock washer wing nut wing nut lock washer wing nut wing nut Steps 1 2 Traveler Advantage Steps 1 2 Traveler L3 L4 Steps 1 2 Traveler S
2. on bolt Use Phillips screwdriver and 7 16 wrench to tighten until both tubes are secure B10320F INS LAB RevB11 3 MAINTENANCE A WARNING Inspect the O IV Holder frequently and tighten it as needed to ensure se cure installation Check holder at least once a week to ensure all parts lock securely into place and will not acciden tally unlock Wipe holder with a soft cloth and dry immediately if exposed to moisture If neces sary wash with a mild soap and water solution rinse and dry with a soft cloth A NOTICE Never use abrasive cleaners or scouring pads on any part of the O2 IV Holder WARRANTY GF Health Products Inc warrants the Everest amp Jennings B10320F O2 IV Holder for three months against manufacturer s defects If a product is deemed to be under warranty GF Health Products Inc shall provide at its option 1 replacement of any defective part or product or 2 a credit of the original selling price made to GF Health Products Inc s initial customer The warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and under standings with respect thereto The recipient of this document hereby acknowledges and repre sents that it ha
3. E Steps 1 2 Traveler HD 1 Note that left sideframe above is shown from inside Install lower holder section on left rear sideframe lower rail Insert U bolt over rail then through appropriate lower holder bracket holes as shown above Install washers and wing nuts on U bolt ends securing holder to rail 2 Install on sideframe backpost Insert U bolt over backpost except Traveler HD insert U bolt over offset tube behind backpost as shown above then through upper bracket as shown above Install washers and wing nuts on U bolt ends securing holder to backpost offset tube 3 Tighten all four wing nuts until holder is secure on sideframe as shown at right Ensure holder is securely attached before proceeding to HOLDER a ASSEMBLY Tavalea divantade Step 3 B10320F INS LAB RevB11 1 PARAMOUNT XD HOLDER AND ADAPTER INSTALLATION ON WHEELCHAIR SEE ILLUSTRATIONS AT RIGHT Tools required Phillips screwdriver M5 hex key M13 wrench Remove O2 IV Holder and adapter from carton and protective packaging 1 Use M5 hex key and M13 wrench to remove the two socket head screws in p B lt screws j M8 x 45 crews S 9 j rear wheel M8 b a 2 left sideframe backpost located directly P axle block above the rear wheel axle block and lt g left sideframe _ replace them with the M8 x 45mm hex gt shone TOMmLINSIGE gt socket head screws as shown in Step 1 Step 1 Install M8 x 45 screws illustration at
4. on IV hang m er Loosen height adjustment knob as necessary Slide upper tube down into middle tube until desired height is reached then tighten height adjust ment knob until secure Adjust IV hanger height 3 Loosen knob until hanger slides freely inside tube 4 Slide hanger to desired height Tighten hook knob until hanger is secure in tube A upper OPERATION knob a A WARNING Ensure the O7 IV Holder te middle __ _IV hanger is installed as described and all a tube heightadjustment CGP components are securely fastened Os bottle before use anti rattle knob Install O2 cylinder Loosen anti rattle knob as necessary in stall cylinder and tighten knob enough to prevent cylinder from rattling Step 2 Install IV hanger ALL MODELS LOCK MIDDLE TUBE IN PLACE WITH BOLT OPTIONAL Tools required Needlenose pliers Phillips screwdriver 7 16 wrench You may wish to use the included optional bolt and nut pliers to more securely attach the middle tube to the lower section bution 1 Depress button lock and remove middle tube from ead lower tube 2 Remove button lock from lower tube Depress button remove install while holding button lock with needlenose pliers Re button lock bolt amp nut move button lock from holder as shown at near right 3 Slide middle tube down over lower tube until holes match Insert bolt through both tubes as shown at far right 4 Install nut
5. right Note that left side frame is shown from inside 2 Assemble T plate to the upper holder bracket with the two M8 flat head screws and lock nuts The T plate must be lo cated between the sideframe and upper holder bracket Tighten the lock nuts securely 3 Install the upper holder bracket with T plate to the inside of the left frame by aligning the T plate with the M8 x 45mm hex socket head screw ends and install ing the M8 lock nuts Tighten the lock nuts securely 4 Place the short spacer plate between the sideframe lower rail and the lower holder bracket and assemble the U bolt lock washers and wing nuts Tighten the wing nuts securely 5 Ensure holder is securely attached before proceeding to HOLDER ASSEMBLY 6 The remaining U bolt washers and wing nuts may be discarded j screws Aef a head RS T plate et holder bracket lock nuts Oz holder T plate and gt upper bracket Step 3 Install T plate on inside of frame lower holder bracket la i and wing nuts Step 4 Assemble lower holder bracket to lower rail 2 B10320F INS LAB RevB11 HOLDER ASSEMBLY CH 1 Install holder middle section slide middle tube down over lower tube until middle 2 button lock locks into hole as shown at middle tube middle right section e pi VA section A WARNING Ensure that button lock J o is locked in place before continuing lower ra section A 2 Install holder upper secti
6. s not relied on any representation assertion guarantee warranty collateral con tract or other assurance except those set out in this document GRAHAM FIELD www grahamfield com GF Health Products Inc is not responsible for typographical errors Packaging warranties products and specifications are subject to change without notice Graham Field Everest amp Jennings E amp J and Traveler are registered trademarks of GF Health Products Inc 2011 GF Health Products Inc 2935 Northeast Parkway Atlanta GA 30360 tel 770 368 4700 4 B10320F INS LAB RevB11