Home

OWNER`S MANUAL - Crown Verity Inc

image

Contents

1. 5 MANUAL MODELS MCB30 6 MCB48 MCB60 amp MCB72 REVISED MARCH 2001 PLEASE RETAIN FOR FUTURE REFERENCE Ip Warnock Hersey bt T US CONGRATULATION S You are the proud new owner of the finest commercial mobile charbroiler available CROWN VERITY Inc charbroilers are designed to last a lifetime or more With proper care and maintenance your charbroiler will provide unparalleled performance and countless years of outdoor cooking Please read this manual carefully to ensure safe operation and to maximize your cooking enjoyment It is your responsibility to see that your grill is properly assembled installed and cared for Failure to follow instructions in this manual could result in serious bodily harm and or property damage WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com TABLE OF CONTENTS Installing Your Mobile Charbroiler rr Storing Your Mobile Charbroiler Cylinders and Regulators hr hrs Hoses and Regulators Leak Testing 1
2. THE FOLLOWING MUST BE CHECKED Cylinder valve including threads into tank All cylinder welds Regulator fitting s and cylinder connection All hose connections All valve connections 1 Open gas supply valve to the charbroiler 2 Brush soap solution on all connections and components listed above 3 Observe each place for growing bubbles which indicate a leak is present 4 Tighten any leaking connection until a repeat test shows no evidence of leakage shut off gas supply while correcting the leaks DO NOT USE THE CHARBROILER IF ANY LEAKS CANNOT BE STOPPED TURN OFF THE GAS SUPPLY VALVE REMOVE ANY GAS CYLINDER AND CALLA QUALIFIED GAS APPLIANCE SERVICE PERSON FOR PROPER REPAIRS WARNING NATURAL HAZARD SPIDERS Spiders and other insects are attracted by the smell of gas and could make webs or nests in the burners This could partially or completely block the flow of gas through the venturis and is indicated by a smoky yellow flame and or a burner that is difficult or impossible to light Ultimately it may cause the gas to burn outside the venturis which can seriously damage your grill If this happens immediately shut off the propane at the cylinder or natural gas at the main shut off valve To prevent and or correct this occurrence periodically check the venturis for obstructions by inserting a pipe cleaner or flexible wire through the air inlet of the burner and twisting it see fig 2 pg 3 Ensure venturi tu
3. 17X18 ol B 47 48 SECTION A A FOR ORDERING PARTS PLEASE CONTACT CROWN VERITY AT 519 751 1800 Due to a continuous program of product The drawing is the property of Crown Note Please specify model number improvement Crown Verity Inc reserves Verity Inc and it is not to be reproduced type of gas and serial number when the right to make changes in design and without expressed written consent of ordering replacement parts Example in specifications without notice Crown Verity Inc MCB 48 propane mmm 2005 Roll Dome Handle 12 200 2030 2050 704 TH 205 708 Tm pon 12 2070 Radiant 3 13032 Lighter Tube 36 amp LH 72 MCB 15 4033 6037 17 16033 Lighter Tube RH 60 MCB 7033 igter 2105 2208 27 Bumper 30 amp 60 MCB 20 2209 33 Bumper 36 amp 72 MCB 2210 45 Bumper 48 MCB 23 02 om Dm 2 3025 El EJ is is x ms Cooking Grate 22 x 20 1 2 ri moss ne Caster Mount Stiffener 144 2216 Caster 5 Spoke Wheel 14 Plastic Spoke Axle Washer 148 2148 Axle Pin 149 2214 Cylinder Bracket Assembly 2200 Hose amp Regulator Assembly Propane 51 2180 1 2 Regulator Natural Gas 36 amp 48 MCB 2189 3 4 Regulator Natural Gas 60 amp
4. 12 inches from side s 24 inches from back See Fig 1 pg 3 This appliance is suitable for use on combustible floors Always level your MCB front to back amp side to side Always keep the area surrounding your charbroiler clear of all combustible materials gasoline or other flammable liquids e Use your charbroiler OUTDOORS in a well ventilated space preferably 10 ft from dwellings or outbuildings Casters must be locked when appliance is in operation CAUTION FOR FIXED FUEL SUPPLY SYSTEMS RE PRESSURE TESTS 1 The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 45 kPa 2 The appliance must be isolated from the gas supply piping system by closing it s individual manual shut off valve during any pressure testing of the gas supply piping System at test pressures equal to or less than 1 2 psi 3 45kPa CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com CLEARANCES TO COMBUSTIBLES FIG 1 24 12 e Ge 12 BURNER ASSEM BLY DETAIL FIG 2 VENTURI AIR INLET 5 16 x 5 8 APPROX N 3 1 CROSS OVER BURNER VALVE ORIFICE d P AIR SHUTTER 7 BURNER STORAGE DAY TO DAY S
5. 43 3 3 3 x xx 0330808 ee Prior To Use and Lighting Instructions rrr Operating and Shut Down Instructions rns 10 Tips and Techniques cee aiaa 11 Cleaning and Maintenance 12 Troubleshooting Guide 13 Conversion peice ee ee a ee ee SOR ee 14 Frequently Asked Questions about MCB s 16 Parts and Components ce eee eee ee eee ees 17 CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com FOR YOUR SAFETY IF YOU SMELL GAS 1 Shut off gas supply to appliance 2 Extinguish any open flame 3 Open lid or remove storage cover s 4 If odour continues immediately call your gas supplier DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance Never check for leaks with a match or open flame An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance This appliance shall only be used in a well ventilated space and shall not be used in a building garage or any other enclosed area WARNING Keep any electrical supply cord and fuel supply hose s away from any hot surfaces DO NOT use your charbroiler
6. 72 MCB 52 5110 1 2 Natural Gas Hose c w Quick Disconnect 36 amp 48 MCB 5 Natural Gas Hose c w Quick Disconnect 60 amp 72 MCB 35 2205 Rol Dome Pint Assembly s R Dome Stapte 29 CROWN crown VERITY INC CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com
7. For safety reasons the LP gas cylinder if supplied with your charbroiler has been shipped empty The cylinder must be purged of air and filled prior to using on your charbroiler When getting your cylinder filled e Allow only qualified LP gas dealer to fill or repair cylinder s Do not allow the cylinder to be over filled Make sure the LP gas dealer checks the cyinder for leaks after filling HOSES AND REGULATORS WARNING Propane Gas Models Your charbroiler is designed to operate on L P propane gas at a pressure regulated at 11 water column The regulator s supplied with this charbroiler is are set to this pressure and must be used This regulator is equipped with the Type I Q C C 1 quick closing connection system which incorporates the following features 1 Will not allow gas to flow until a positive seal has been made 2 Has a thermal element that will shut off the flow of gas if subjected to temperatures between 115 and 150 C 240 amp 300 F 3 Has a flow limiting device which when activated will restrict the flow of gas to 10 cubic feet per hour 25000 BTUs TYPE CYLINDER CONNECTIONS If the large black thermally sensitive coupling nut is exposed to temperatures above 115 150 C it will soften and allow the regulator probe to disengage from the cylinder valve thereby shutting off the flow of gas Should this occur do not attempt to reconnect the nut Remove the entire regulator assembly an
8. contained propane system charbroiler is designed for use with a 9 1 kg 20 Ib propane cylinder equipped with a Type I cylinder valve This charbroiler cannot be connected to a standard Type II valve with internal left hand threads only DO NOT CONNECT TO A PROPANE GAS CYLINDER EXCEEDING THIS CAPACITY OR USE A CYLINDER WITH ANY OTHER TYPE OF VALVE The Type Q C C 1 valve is recognizable by the large external thread on the outlet part of the valve Standard valves do not have these exterior threads Any attempt to fit the regulator s with anything other than the mating Type Q C C 1 connector recognized by the large black coupling nut will negate the important safety features designed into the Type Q C C 1 system Fitting a standard 4510 P O L connector will not provide the flow control or temperature shut off safety features built into the complete Type I Q C C 1 system The cylinder should not exceed 472 mm 18 1 2 in height and 317 mm 12 1 2 in diameter Some models may be supplied with a propane cylinder If purchasing a cylinder for your gas charbroiler it must be constructed and marked in accordance with the specifications of a Canada The Canadian Transport Commission b U S A The U S Department of Transportation The cylinder must also be equipped with a A shut off valve terminating in a proper cylinder valve outlet specified in current standards 1 Canada CAN CGA 1 6 M88 Outdoor Gas G
9. you can sear meats over a high flame on one side of the charbroiler while you slow a roast in a roasting pan on the other The multiple cooking arrangement also makes it possible for you to turn your charbroiler into an outdoor baking oven Light one side of the grill and place the food on the grill above the unlit side Close the lid and turn the control s to low The heat from the lit burner s gently circulates throughout the charbroiler cooking the food by indirect heat A thermometer in the roll top s will help you monitor the inside temperature CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com 12 CLEANING AND MAINTENANCE All Crown Verity Inc charbroilers are easily cleaned because of their stainless steel construction For minor clean ups we suggest a general purpose mild cleansing formula For heaw grease build up apply an oven cleaner to stainless steel surfaces only following the manufacturer s instructions MCB s be thoroughly cleaned inside and out with the use of a pressure washer Do not expose regulators control valves or decals to high pressure spray Cooking Grids Prior to each use apply a light coating of cooking oil to the grids to prevent food from sticking After each use scrub the grids with a stiff nylon pad or brass brush Do not use steel brushes Grids can also be washed with mild deter
10. AND MCB 72 CONVERSION SET UP TABLE MODEL SERIAL NUMBER DIM MCB 72 961001 961371 59 1 2 MCB 72 961373 961450 63 1 2 MCB 72 961451 amp UP 56 1 4 MCB 60 961001 961450 51 1 2 MCB 60 961451 amp UP 44 1 4 16 FREQUENTLY ASKED QUESTIONS ABOUT 5 Q My charbroiler works great when it s completely lit but have problems getting all the burners to light Do have a gas leak in the system causing the flow limiting device to activate A Not likely Make sure all burner valves including pilot valve are OFF clockwise Open the LP cylinder valve Wait 15 seconds before attempting to light pilot This will allow the pressure in the gas piping system to equalize and will allow the flow limiting device to reset itself The device will activate every time the cyinder valve is opened to a non pressurized piping system and it takes a few seconds to re set itself before it can handle the large amounts of gas required to run an MCB Remember when this device activates it still allows a small amount of gas to pass through enough to run the pilot tube and one burner adequately The reason the device activates is because when an LP cylinder valve is opened to a non pressurized piping system the rate of gas flow exceeds for a split second the capacity of the device All MCB piping systems will equalize within 15 seconds prior to lighting attempts However if a burner or pilot valve is left open the de
11. TORAGE Always turn off the gas supply valve and disconnect supply hose f you have not purchased the roll top s with your unit your charbroiler is supplied with a protective cover s Install the cover s to protect your grill from the elements Never attempt to light your charbroiler unless the lid s are open or the cover s are removed LONG TERM STORAGE To prepare your charbroiler for long term storage follow these steps Preparation Clean the inside of your charbroiler Clean the burner s then lightly oil Clean the cooking grids lightly oil cooking oil store indoors Store LP cylinders outdoors out of reach of children away from sources of heat and sources of ignition Cover the charbroiler if left outdoors Cover the supply hose connection s with cap s or plastic bag and elastic FIXED L P NATURAL GAS MODELS Equipped with quick connect hose W hen the charbroiler is not in use the gas must be turned off at the shut off valve and the hose must be disconnected from the charbroiler Install plastic caps to quick connect fittings The charbroiler may then be stored indoors or outdoors For long term storage follow the storage instructions above CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com 5 CYLIN DERS AND REGULATORS LP GAS CYLINDER self contained Propane Gas System The self
12. UTION WHEN WORKING AROUND HOT SURFACES 13 TROUBLESHOOTING GUIDE WHAT HAPPENS WHAT TO LOOK FOR 1 Burners will not light Out of propane Improper lighting procedures 15 cylinder valve turned on Regulator assembly not fully tightened to cyinder valve Gas piping system is full of air Bleed out system wait five minutes and repeat lighting procedures Large black nut on cyinder connector is cracked or has been overheated and is not making a gas tight seal inside cylinder valve Replace regulator and hose assembly 2 Flames blow out on low Has charbroiler been sufficiently preheated before turning to low Is the venturi properly seated over the orifice Inspect both venturis and burner holes for obstructions and check for proper air shutter opening on venturis 3 Burners are not hot enough Leaving burner valve open before opening cylinder valve or leak in system causing flow control device to activate Follow proper lighting sequence or correct leak in system Inspect venturi for obstructions and alignment Make sure burners are clean 4 Flashback flame coming up Immediately shut off gas supply at cylinder valve Allow venturi around charbroiler to cool Check venturis and orifices for console control knobs obstructions See fig 2 pg 3 Excessive grease build up around control valves has caused a grease fire Clean charbroiler If problem persists contact qualified service person 5 Grease dripping from bas
13. bes are properly seated over the orifices CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com PRIOR TO USE AND LIGHTING INSTRUCTIONS WARNING Do not use your charbroiler until you have read and understood all the information in this manual and you are assured There are no leaks in the gas supply system see Leak Testing section The burner is properly assembled with the venturi tubes seated over the valve outlets orifices Fig 2 page 3 That any electrical supply cords and or gas supply hoses are kept away from all hot surfaces Your charbroiler is positioned in a safe location see Installation section CAUTION Always open the lid s or remove storage cover s before attempting to light your charbroiler Do not bend directly over the grill when lighting Make sure all valves are OFF Slowly open LP cylinder valve Do not snap open Wait 15 seconds before opening a burner valve This will allow the pressure to stabilize in the system allowing the flow limiting device to reset itself If ignition does not immediately occur turn off all burner and pilot valves wait 5 minutes and repeat LIGHTING INSTRUCTIONS Open all lids on the charbroiler Ensure that all valve handles are in the OFF position clockwise Turn on the gas supply valve WAIT 15 SECONDS Turn the lighter t
14. conversions and installations Crown Verity Inc accepts no responsibility for property damage or personal injury as a result of improper installation maintenance adjustment or otherwise INSTALLATION amp CONVERSION INSTRUCTIONS TO THE INSTALLER The supply piping for natural gas or LP gas shall be sized correctly to meet the input requirement of the appliance Manifold pressures shall be checked and adjusted if necessary to the pressures stated on the rating plate i e 11 W C propane 3 5 W C natural gas Models MCB 60 and MCB 72 have two manifolds When connecting to a natural gas supply or fixed LP supply the manifolds must be coupled together A typical set up and dimensions are illustrated on page 15 A one piece manifold for MCB 48 is available single inlet Quick Disconnect Devices Any quick disconnect devices and hoses used in the supply arrangement shall be sized correctly to meet the input requirement of the appliance and shall comply with any other hose requirements mentioned earlier in this manual and national and local codes They shall also be equipped with a suitable shut off valve located as close as practical to the appliance 15 MANIFOLD COUPLING PIPE DETAIL SEE TABLE 3 4 NPT 3 4 NPS SHORT 3 4 SCH 1 GAS PIPE 3 4 UNION MCB 60 AND MCB 72 MANIFOLD COUPLING PIPE MANIFOLD COUPLING 3 4 TEE 90 ELBOW NIPPLE 3 4 NPS GAS PIPE 3 4 UNION FLOW MCB 60
15. d from the propane cylinder If the fitting is allowed to drag on the ground damage to the fitting may occur resulting in leaks or an incomplete connection Dirt could also enter the small inlet hole blocking gas flow completely NATURAL GAS AND FIXED LP MODELS RE HOSES Crown Verity Inc charbroilers that are equipped for use with natural gas or fixed LP systems require care and attention to the hose e Inspect the hose clean quick connect coupling and keep protected Always disconnect hose at quick connect coupling when storing charbroiler The gas supply hose must be a minimum of 10 ft 3 1 m and must be equipped with a shut off valve and must be installed by a certified technician The appliance must be disconnected from the gas supply piping during any pressure testing of the system at test pressures in excess of 1 2 PSIG 3 5 kPa The outlet pressure setting for the pressure regulator provided with the appliance is 3 5 water column for natural gas 11 water column for propane LEAK TESTING Leak testing must be performed i before lighting your charbroiler for the first time ii every time the propane cylinder is refilled or any gas component is changed or iii at least once per year Perform the leak test outdoors in a well ventilated area away from any open flame heat or ignition sources DO NOT SM OKE Use only a 50 50 mixture of liquid soap and water for leak testing Do not use a match or open flame
16. d replace it with a new one see parts list The cause of the excessive heat should be determined and corrected before operating your grill again The regulator probe also contains a flow sensing element which will limit the flow of gas to the regulator to a manageable amount 10 cubic feet per hour in the event of a hose or regulator failure or a leak If it is evident that the flow limiting device has activated the cause of the excessive flow should be determined and corrected before using your grill again NOTE Improper lighting procedures can cause the flow limiting device to activate resulting in reduced heat output If this is suspected shut off all burner controls and cylinder valve and carefully repeat lighting instructions step by step Do not remove the nut and probe and do not attempt to connect to anything other than a mating Type Q C C 1 cylinder valve Never connect a propane gas grill to an unregulated propane gas supply or other gas Do not attempt to alter the hose or regulator in any way Do not allow the hose to come in contact with any hot surfaces of the charbroiler Visually inspect the entire length of the hose assembly before each use for any evidence of damage cuts cracks burns or excessive wear If found replace the assembly before using your charbroiler Only a hose assembly as specified in the parts list for your charbroiler should be used The connection fitting must be protected when disconnecte
17. e Has grease tray been installed Is charbroiler level Excessive grease build up Clean unit 6 Charbroiler goes out after a The cylinder pressure has dropped below operating period of time pressure due to freeze up Long periods of full open operation will cause this Remedy exchange cylinder with a new full one 7 Excessive flare up Overload of fatty meat Clean charbroiler Add water to grease tray s Level unit first See tips and techniques page 11 14 CONVERSION FIXED LP AND NATURAL GAS SYSTEMS MOST Crown Verity mobile charbroilers are factory equipped for use with a propane cylinder s If your unit is factory converted for connection to a fixed supply piping system the rating plate will reflect the type of gas to be used The burner orifice sizes are indicated on the rating plate WARNING Never use a gas grill with any gas other than that indicated on the rating plate Due to the numerous possible arrangements it is recommended that you call the factory for technical assistance and instruction on proper conversion procedures The manufacturer supplies all conversion equipment kits Note To order conversion kit s call Crown Verity Inc at 519 751 1800 or fax 519 751 1802 Technical help is available during most weekday business hours When ordering your conversion kit s please state the type of gas to be used and the model number of your charbroiler WARNING A certified technician must perform all
18. gent or baking soda Exercise caution when cleaning hot surfaces CARBON OFF Crown Verity Inc is pleased to introduce CARBON OFF the world s WORKS FAST leading heavy duty carbon grease Om OST ECR remover Please contact Crown Verity SPRAY ON Inc for more details on how to order RINSE OFF CARBON OFF USTING AIR SHUTTERS Crown Verity Inc charbroilers are equipped with adjustable air shutters on the burner venturi assembly The air shutters are factory set for use with both natural gas and LP gas and should not need adjustment However if adjustment becomes necessary they may be adjusted as follows Should be performed by a qualified technician Light the charbroiler and leave on high setting Check that the flame is mostly blue some random yellow flecks are normal as is a muffled pop when the burner is turned off If the flames are mostly yellow or the flames are noisy and lift off the burner ports venturi air shutters require adjusting as follows a Loosen air shutter screw b Increasing the amount of air opening will reduce the amount of yellow flame producing the desired short blue cones C Decreasing the amount of air opening will soften the flame and correct a noisy lifting flame condition however should still be mostly blue in colour Note Due to the location of the air shutters you will have to make the adjustments while the burners are off re light and observe the flames USE CA
19. if there is evidence of damage cuts cracks burns or excessive wear to the hose DO NOT obstruct the flow of combustion and ventilation air to the charbroiler DO NOT place combustibles on undershelf Do not stand on the undershelf it could result in injury or irreparable damage DO NOT store a spare LP propane cyinder under or near your charbroiler DO NOT leave your charbroiler unattended while in operation DO NOT allow children to play on or near your charbroiler DO NOT use under the influence of alcohol or drugs DO NOT use this charbroiler until you have read and understood all of the information in this manual This appliance has been tested according to ANSI Z83 11a CGA1 8a M97 This outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles and or boats 2 INSTALLATION THE INSTALLATION OF THIS APPLIANCE MUST BE IN ACCORDANCE WITH 1 All applicable local codes or in the absence of local codes 2 1 Canada must conform to current National Standard CAN CGA B149 1 amp 2 natural gas propane installation code ii U S A must conform to national Fuel Gas Code ANSI 7223 1 1988 or latest edition WARNING DO NOT operate this appliance under overhead unprotected construction This appliance shall be used only in a well ventilated space and shall not be used in a building garage or any other enclosed area Minimum clearance to adjacent combustible materials
20. off This will ensure the flavour of your food For best cooking results always preheat your charbroiler CONTROLLING FLARE UPS Some flare up during grilling is desirable since the burning juices from the meat creates the smoke which gives barbecued food its unique flavour and appearance However excessive flare up can not only ruin your food it may lead to a dangerous condition particularly if a build up of grease in your charbroiler ignites resulting in an uncontrolled grease fire We suggest adding about 1 of water to the grease tray s prior to cooking This will cool the falling grease and facilitate clean ups To Minimize flare ups Trim excess fat from meats before cooking Cook fatty meats chicken and pork on low setting or by indirect method see section below Check that grease tray s is in place amp add 1 of water Do not cover cooking grids with foil or use broiling pans Allow drippings to fall into the grease tray s COOKING TECHNIQUES There are several ways to cook on your Crown Verity Inc charbroiler here are but a few Lid Up or Lid Down Although keeping the lid up or down when grilling directly on the grids is a matter of personal choice you ll find your charbroiler will keep a more constant temperature and your food will cook in less time using less energy with the lid down For cooking which requires a long cooking period over a low flame keep lid down Direct or Indirect M ethod Now
21. rills Amend 1 2 U S A ANSI CGA V 1 1977 Compressed gas cylinder valve outlet and inlet connections b A safety relief valve having direct communication with the vapour space of the cylinder C A collar to protect the cyinder shut off valve d An arrangement for vapour withdrawal A bottom ring for securing to the cylinder support assembly WARNING Always turn off the cylinder valve when your charbroiler is not in use Handle cyinder valves with care Never connect an unregulated LP gas cylinder to the charbroiler Never store a spare cylinder under or near your charbroiler or subject any cyinder to excessive heat Always keep cylinder s securely fastened in an upright position TRANSPORTATION AND STORAGE OF LP CYLINDERS Although safe to use when properly handled careless handling of a propane gas cylinder could result in fire explosion and or serious injury THEREFORE Always use the protective cap provided with your cylinder whenever it is not connected to your charbroiler Do not store in a building garage or any other enclosed area Store only in a well ventilated area Do not store in the vicinity of any gas burning apparatus or in any high heat area such as a closed car or trunk Do not smoke while transporting a cylinder in your vehicle Do transport and store cylinder s in an upright position Do not tip on its side Do store out of reach of children WARNING FILLING
22. termine if a leak has caused the flow limiting device to activate f the burner flames go out when your charbroiler is in operation immediately turn off all control valves Wait 5 minutes to clear the gas before attempting to re light the charbroiler If the problem persists check the troubleshooting guide pg 13 Visually check the flames every time you light your charbroiler A good flame should be mostly blue If the flame is abnormally small or mostly yellow shut off the charbroiler and check the venturi tubes for blockage Fig 2 page 3 then check the troubleshooting guide pg 13 SHUT DOWN INSTRUCTION S 1 Turn all burner and pilot valve knobs to the OFF position 2 Turn the LP supply valve to the OFF position For natural gas systems turn the gas supply valve to the OFF position 3 Ensure all burners are extinguished 4 Close lid s or install protective cover s until future use 5 Disconnect LP cylinder s from the charbroiler when not in use 6 Take care your charbroiler is still hot CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info crownverity com 11 TIPS AND TECHNIQUES BREAKING IN YOUR GRILL Before cooking on your Crown Verity Inc charbroiler for the first time operate it on high for 10 minutes with the lid s open then with the lids closed for a further 10 minutes to ensure any dirt or protective oil has burned
23. ube pilot valve to the ON position Note two lighter tubes are provided on larger models one for the left side and one for the right side 5 Insert a match or barbecue lighter into the hole s provided on the end s of the charbroiler A U Ne 6 Visually check to ensure the lighter tube is burning Once the lighter tube has been lit any other main burners can be lit Push in and turn to high The unlit burners will then light automatically 8 Visually check to ensure that all burners that are intended to be ON are lit 9 Adjust individual burners as desired N 10 OPERATING AND SHUT DOWN INSTRUCTIONS OPERATING Minimum operational temperature of this appliance is O C or 32 F Main burner valves are adjustable over a full range from completely ON to completely OFF Note burner valves lock when shut off To open burner valves you must push in and turn counter clockwise Do not force the controls damage to the valves or knobs may result Note If the heat output from the charbroiler seems abnormally low it may be caused by the regulator flow limiting device being activated by i improper lighting procedures or ii a substantial leak in the gas system If the former is suspected shut off the cyinder valve and all burner valves then carefully follow lighting procedures step by step ensuring all valves including pilot are OFF before beginning If the latter is suspected perform the leak test procedure to de
24. vice cannot reset itself because it has no back pressure with which to do so Q My charbroiler takes forever to light Why is that A The piping system fills with air when cylinders or supply hoses are disconnected and it takes some time to bleed the air out of the system through the small pilot orifice holes Be patient Q How long will my L P cylinder last A Good question the formula used to calculate this accounts for only two thirds of the cylinder s capacity Not to say that MCB s wont work after the first two thirds of the propane are used up but that the pressure in the cylinder begins to drop significantly at that level Using this formula W ith a twenty pound cylinder full and using the average maximum input amount of gas used for MCB s We came up with an average cylinder life of 3 to 3 1 2 hrs CROWN VERITY INC 37 ADAMS BLVD BRANTFORD ON CAN N3S 7V8 TEL 519 751 1800 FAX 519 751 1802 www crownverity com Email info amp crownverity com 17 PARTS AND COMPONENTS 4 Re O OD _ FI 39 40 41 x 2 ri 4 5 6 26 27 28 29 181 141 151 16 20

Download Pdf Manuals

image

Related Search

Related Contents

Honeywell 88065 User's Manual  CASA: HOW TO  Geschäftsprozessmodell-basiertes Management  LG 42LB580 42" Full HD Smart TV Wi-Fi Black LED TV  可動式専用架台:TM-ST500 取扱説明書    Formes Urbaines et Densités  Comparatif des dispositifs de surveillance de pression des    販売名:アルゴンガス手術装置の付属品  

Copyright © All rights reserved.
Failed to retrieve file