1.    S1  Mercury relay   C4 5 6  Coupling capacitor  L1 C1 L2 C2 L3 C3  Filter  R1  Charging resistor    o EUT L1    EUT L2 o   o0 0 rr   o EUTL2 R2  Termination resistor  EUT PE o   o EUT PE CP1 2  Circuit breaker  oO CC  Coaxial cable  616263 o O SG    The HV power supply charges up the capacitance component  of the coaxial line through the charging resistor when the  mercury relay is in off status  The stored energy is discharged  when the mercury relay contacts turn on  generating a HV  square wave pulse across the 50  terminating resistor  The  injection unit couples this pulse through a capacitor to an EUT  LINE  Also provided is a decoupling circuit consisting of an  inductor and a capacitor  working as a high impedance circuit  when seen from the injection point  This enables the unit to  effectively couple the interference signals to the EUT and to  reduce their leakage into the power supply side  LINE IN      V R2 Zo Vage R2 320 V R2 1 3Zo  1 2E  3 8E    3 16E      1 16E                      t t t  1 8E    Vp R2  Zo R2  x E   Vp  Peak voltage being measured across the terminating  resistor   R2  Value of terminating resistor   Zo  Characteristics impedance of the cable   E  Output voltage from the HV power supply       E  niceken               E Gl G  RE Bae    Impulse Noise Simulator    INS 4020 and 4040    OUTLINES OF TEST SET UP  EXAMPLE  INS 4020 4040     e Test environments  A recommended test set up example is shown here        Impluse Noise Simulator Model  INS
2.    m  m p R    EL Ji A JA   di   Total Coordinator for EMC             r i i    mE EN    i d z a m Em i       INS AK2    Noise Laboratory Co  Ltd   www noiseken co jp    Compliance to a standard or to the real world     No one could have doubt  as to the importance of the  pulsed EMI test    In fact  in the scheme of  international compliance   the Electrical Fast  Transient  Burst test is a  must for almost all  products    As logic circuits get faster   they tend to be more  susceptible to higher  frequency disturbances   Does your test program  represent this scenario     Noise related malfunctions of electronic equipment containing electronic  control devices  such as information technology equipment  are now  becoming a serious problem in today s society    One of the best known sources of interference is the inductive component  through which a current is interrupted  It is represented by the switching  on and off of a relay  This type of noise has a broadband interference  spectrum  thus it is coupled to wires and printed circuits in equipment   reflecting and resonating and being amplified by an IC to cause equipment  malfunction     A market proven conducted immunity test method   The Impulse Noise Simulator  abbreviated to INS  design comes from test  equipment invented by an American computer manufacturer in early 1970 s  when events of malfunctions of digital equipment had just begun to emerge  in society  Now the INS method is the established test method in Japan
3.   R5  to R8 and C2 to C5  components to form LC filter circuitry     For the basic INS series simulators operating principle  refer to page 9   The above schematic illustrates how the INS AX2 series simulators have achieved complete elimination of the operator   s  intervention in terms of manual plugging and unplugging of coaxial connectors     The coaxial reed relay RL3 to RLJ work to form given lengths of the charged coaxial line  The pulse width of 10ns is available  when all these relays are open  In contrast  the unit generates the 1000ns width pulse with all the relays closed     The relays RL10  RL11 and RL12 select the route of the pulse output between PULSE OUTPUT and EUT LINE OUT as well as  the termination method     The units U1 and U2 are controlled and provide all the combinations of the coupling modes     The above schematic shows the states of the relays and switches for the sep up of   10ns pulse width  charged line 50 ohm terminated  interference signals coupled in common mode  of N to SG      a  gt        Impulse Noise Simulator    INS AX2 series 220 420 250 450  HSPECIFICATIONS    Parameters       Pulse output voltage       specifications    0 01     2 00kV 10  220 250  at 0 01kV step   0 01     4 00kV 10  420 450  at 0 01kV step    0 04kV allowance for  lt 0 1kV setting   When the output is terminated by the internal resistors        Output polarity    Pulse width    Positive  Negative    50 100 200 400 500 800 1000ns  10   10ns  3ns       Rise time     
4.  4020 4040         To the power supply for the simulator    Braided wire    To Power supply for EUT    rouna plane    i Insulation sheet  Isolation transformer                                J E wooden test table  X Coupling adapter q     for signal lines testing only  not shown here              AE     Notice  EUT LINE INPUT for AC powered testing shall be power fed from an isolation transformer   Place a ground plane beneath the simulator and EUT  The plane shall be grounded for safety     TEST SET UP    e Line to ground mode  common mode  for AC operated equipment    INS 4020 4040    PLS OUT        EUT                                LINE OUT  EUT L1          LINE IN    EUT L1    ISOLATION EUT L2  TRANSFOMER    L1      if  L2  o    PE  o l                      EUT L2                      AC IN                EUT PE       EUT PE                                                                                                           GROUND PLANE    SG SHORT PLUG     1 Mount the OUTLET PANEL matching the EUT and then plug the EUT AC cord to the panel  receptacle  In case the AC cord is too long  fold it so that it might not cross with signal or other  cables     2 Plug the SG   signal ground  connector with the SG short plug     3 Connect the SG terminal of this unit and FG   frame ground  terminal of the EUT to the ground  plane by using low impedance wires  for example  braided wire of 3 5mm2 of the shortest possible  length     4 In case the EUT consists of plural units  e
5.  BOPTIONAL ACCESSORIES FOR INS    Coupling Adapter Model CA 805B    Input voltage  4 000V max  Input pulse width  50n 1 us  Diameter for clamping cable  26mm max    m Coupling Adapter MODEL CA 803A    Input voltage  2 000V max   Input pulse width  50n 1 us   Coupling ratio  20 1   Terminator  50Q terminator built in  Diameter for clamping cable  15mm max    HEMS Probe Kit MODEL Model  H2 B    A diagnostic tool for locating sensitive spots on the circuits under test to the electric or magnetic transient field  This kit consists of  3 electric and 3 magnetic field probes  all in a different probe head size for a variety of applications  Connected to the INS or FNS   Electrical Fast Transient Burst  simulator  each probe works as a transient field source    Features   Detects possible noise immunity problem spots   Generates transient electrical or magnetic fields   Application for modules  components  conductors and ICs   Convenient handling by pencil shape  light plug type cable with snap action coupling    Input voltage  4 000V max   Input pulse width  50n 1 us   Loop diameter  50  75  100  150  200mm  Cable length  Approx  2m    Input voltage  2 000V max   Input pulse width  50n 1 us   Coupling ratio  10 1   Terminator  50  terminator built in  Diameter for clamping cable  27mm max      Attenuator for waveform observation MODEL AT 810    Input voltage  4 000V max  Input pulse width  50n 1 us  Attenuation  1 100  40dB     Input impedance  500  Output impedance  500  Frequency
6.  and  other Asian countries  In fact  the number of INS units shipped exceeds 5 000     The first priority is to reproduce the upset of digital equipment   If you are facing an immunity problem  the first priority should not be just  testing  but rather built in solutions in your equipment  The simulator you are  about to use must reproduce the identical phenomena happening in the field     Complementary to the IEC61000 4 4 EF T Burst test   The NoiseKen INS series Impulse Noise Simulators with unique valuable  features and capabilities  most of which are not met by Electrical Fast  Transient Burst generators  greatly helps to enhance your test program to  ensure your products are really immune from real world phenomena     FEATURES     1ns rise time square pulse containing a frequency component of up to 2 GHz regions    Variable pulse widths from 50ns to 1us in 50ns steps for compensation for the lack    of a specific interference frequency band     Line to line and line to ground coupling modes     Synchronous and asynchronous pulse placement with AC phase angle     Dedicated capacitive and inductive coupling clamps are optionally available     A market proven test method with a 30 year history    HWAVEFORMS  e amp Square wave               Tii di FB gis Te fd ma  V 500V Div H 500ns Div  50Q termination    edece edge    MFREQUENCY SPECTRUM          TIT    dai re AR  AR    i LI    z r  ied  i        60dB INS series pulse power spectrum   50ns and 400ns width  2000V        Im
7.  characteristics  DC to 500MHz   4dB        Impulse Noise Simulator    INS 4020 and 4040  BINS SERIES ELECTRICAL SCHEMATIC          The simulator design is based on the principle of a charged delay line     DC  OUT    an     Q  O    EUT L1 o g     G       PULSE GENERATION PRINCIPLE    The main components of the pulse generator circuitry of this  unit are coaxial cables  HV power supply  charging resistor   mercury relay  and terminating resistor  The coaxial cables  form a distributed constant circuit consisting of the inductance  of the inner conductor and capacitance between the inner  and outer conductors  When this line is terminated by a 500  resistance  it works as a square wave pulse generator  Pulse  widths vary depending on the delay time of the coaxial line   length of the cable   The proportion of pulse widths to the  length is approximately 10 ns per meter  Pulse waveforms  and amplitudes depend on the relation between terminator  resistance and coaxial cable characteristic impedance     EFOR PERFECT MATCHING    Pulse waveforms and amplitudes are dependent on the value  of a termination resistor being connected to the PULSE OUT  terminal  The figures and equation shown at the right show  their relations  To generate square wave pulses  this unit  adopts a 50Q strictly  53 50 resistance    an equal value to  the characteristic impedance of the coaxial cables     PULSE OUT  502 TERM IN      PULSE IN    S1         J  N  a   LO 502 TERM OUT         HV  HV power supply
8.  the pulse width change     Pauses execution of a test and continues from where it paused  when the PAUSE button is pressed again     Toggles between PHASE  pulses in synchronization with the EUT  supply frequency  and VARIABLE  pulses generated irrelevantly  to the EUT supply frequency        Turns on or off the EUT LINE     Places the unit in status to accept changes of the pulse  placement phase angle in PHASE mode and pulse repetition  period in VARIABLE mode  These two parameters can also be  automatically ramped in the selected steps     Calls the test PROGRAM    Places the unit in status to accept changes of test duration at  each step and time interval between each step        Impulse Noise Simulator    INS AX2 series 220 420 250 450            FRONT PANEL       PULSE OUT    C   O TERM IN    REAR PANEL    INS AX2 250 450  4 wire 3 phase  schematic    HV  high voltage supply   R1  charging resistor   R2  R3  terminating resistor   R4  terminating resistor for externally connected coupling adapter   C1  coupling capacitor   CC  coaxial cable   RL1  contactor   RL2  mercury relay   RL3 to RLY  coaxial reed relays  for pulse width selection   RL10  relay for terminator setting   RL11  relay for PULSE OUT  turns on when an external device is used   RL12  relay for EUT line coupling   U1  motor driven coaxial switch unit  for coupled line selection   U2  motor driven coaxial switch unit  for signal return line selection   U3  triangular wave unit  factory option    L1 to L4
9. ach unit shall be connected to the ground plane     5 When the EUT does not have FG terminal  testing shall be done with the EUT ungrounded to the  ground plane     6 Select the line to which the pulses are to be injected by making a connection from 500 TERM OUT  terminal to the EUT LINE L1  L2 or PE  by using a supplied coaxial cable        10          Impulse Noise Simulator       INS 4020 and 4040  ETEST SET UP    e Line to line  normal mode  for AC operated equipment  INS 4020 4040    JL on  N EUT    502 TERM                                            50QTERM OUT LINE OUT  4       LINE IN  EUT L1                EUT L1                   ISOLATION  TRANSFOMER EUT L2    EUT PE  L1                                                                                                                                 GROUND PLANE 9    SG SHORT PLUG     1 Mount the OUTLET PANEL matching the EUT and then plug the EUT AC cord to the panel receptacle   In case the AC cord is too long  fold it so that it might not cross with signal or other cables     2 Testing shall be done with the SG terminal not being connected to the ground plane  In case the  EUT have an FG terminal  test it both with the FG connected to the ground plane and with the FG    disconnected form the plane    3 Select the line to which the pulses are to be injected by making a connection from SOQTERM OUT    terminal to the EUT LINE L1  or L2  by using a supplied coaxial cable    4 Plug the L2  or L1  connector with the SG s
10. hort plug  while the SG connector shall remain open circuit     e Capacitive coupling test for signal lines  by using CA 805B coupling adapter     INS 4020 4040    PLS OUTO     502TERM IN                            502 TERM OUT             LINE OUT                LINE IN                         EUT L1 9  EUT L2 9  EUT PEQ                                                                                                           GROUND PLANE     sG SHORT PLUG     1 Open the coupling adapter  option  and clamp the interface cable under test  The PULSE OUT  terminal shall be connected to one side of the adapter and the 50QOTERM IN terminal shall be  connected to the other side   Changing the injection and termination sides is also recommended as    test results may vary     2 EUT power can be supplied from the service outlet directly  as the HV pulses are not injected to these    lines    3 Connect the SG terminal of this unit and FG terminal of each unit of the EUT to the ground plane     Designs and specifications are subject to change without notice           NOISE LABORATORY CO   LTD     1 4 4  Chiyoda  Sagamihara City    Kanagawa Pref   229 0037 Japan   Tel   81 0 42 712 2051 Fax   81 0 42 712 2050  http   www noiseken co jp     E mail  salesenoiseken com  0501 07KQO          
11. lt 1 ns       Output impedance    500 system  53  50        PHASE    Injection phase angle 0 to 360 degrees 10 degrees  EUT power supply    gt  AC90V  50Hz 60HZ 10         Pulse repetition mode VALIABLE    10ms   999ms  10  220 250   16ms   999ms  10  420 450           Single pulse generation  each time the 1 SHOT button is pressed   Synchronized output with phase angle setting in PHASE mode    Single phase AC240V DC65V  20A 220 420              Power capacity of EUT 3 phase  4 wire  AC500V DC250V  50A 250 450   50 60Hz 10    Power supply AC100   240V 10  50Hz 60Hz 10    Power consumption 110VA   Operating temperature 15   35  C   Operating humidity 25     75     Weight    Mercury relay unit       W 430xH 350xD 470 mm  projection excluded    Approx  30kg  220 420   Approx  38kg  250 450     Models 04 00014A and 04 00015A for 2kV and 4kV models  respectively      Triangular pulse addition  Factory Option           Parameters specifications  Output pulse waveform Triangular pulse  Pulse output voltage 2kV  220 250  and 4kV  420 450  max  when the output is terminated by the internal resistors   Output polarity Positive  Negative  Duration 1us   30    Pulse  Rise time  lt 40 ns             When the triangular pulse generator has been built in  the original model numbers become INS AX2 220T 420T 250T 450T with    an affix of    T                akan      mm       ni  Impulse Noise Simulator EL       INS AX2 series 220 420 250 450    Remote Control Software  Included accessory   C
12. max  u i      Circuit breaker box MODEL 18 00073A    3 phase AC415V 50A 50 60Hz    m Mercury relay unit for replacement    Model  04 00014A for INS AX2 220  250  Model  04 00015A for INS AX2 420  450       Impulse Noise Simulator         15 4020 and IN        e e    ws    Z       The NoiseKen s INS 4020 4040 is a further development from our  versatile INS series simulators for greater ease of use  durability and  reliability with new technology specifically applied to this new product   The most significant addition is automatic ramp operation in output  voltage  pulse repetition period and phase angle placement     EFEATURES   e amp Automatic ramp operation for output voltage  phase angle and  repetition period    Floating output    amp Coupling mode selection by plugging the supplied coaxial connector  to the selected port    Easily changeable mercury relay   e Built in 50 ohm terminator    Up to 5 test settings can be stored in the memory    Easily changeable outlet panel             INS 4020    ECONTROL PANEL       Selects the polarity   Increment and decrement of the selected parameter  Confirms the setting for each parameter in ramp mode   Saves or calls up test setting     Places the unit in variable period mode  Pulse generated irrelevantly to  the EUT supply frequency  The period can also be ramped according to  the settings     Places the unit in 1 shot mode  each time the button is pressed  a single  pulse is generated     Places the unit in phase mode  Pulse gene
13. n collector negative logic  1 SHOT By trigger switch  a single pulse injection to any phase angle of the power line  Power capacity of EUT AC240V Single phase  DC60V  16A  Power supply 100   240 VAC 50 60 Hz  Power consumption 140VA  Operating temperature and humidity 15 35C 25  75   No dewing shall occur    Dimensions and weight  W 430 x  H 249 x  D 420 mm  Projections exluded    Approx  19 kg             HOPTIONAL ACCESSORIES FOR INS 4020 4040  Ninjection Unit MODEL IJ 4050    Input voltage  8 000V  without 50  terminated    EUT power capacity  3 phase 5 wire AC415V 50A  Coupling selection  By connecting cable   Coupling mode  Normal or Common mode by SG short  plug   Line synchronization  Detects L1 L2 voltage and outputs  the synchronization signal from SYNC OUT terminal  Coupling attenuation characteristic   lt  10dB   1GHz  Power supply  AC100 240V 50 60Hz 20VA max    E Outlet Panel MODEL 18 00059C    JP USA type  AC125V 20A max    Terminal block type  AC240V 16A  DC60V 16A    m Mercury relay unit for replacement  MODEL INS RL2K for INS 4020       m Triangular wave unit MODEL 02 00099A    Pulse shape  Triangular wave   Pulse voltage  4 000V  with 50Q terminated   Pulse width  1us  30    Rise time   lt 40ns   Polarity  Positive or negative    E Outlet Panel MODEL 18 00060B    CEE7 Schuko type  AC240V 16A max    Single phase AC240V 20A 50 60Hz  DC65V 20A    m Mercury relay unit for replacement  MODEL INS RL4KB for INS 4040       Impulse Noise Simulator    INS series      
14. omplete  comprehensive ready made Windows software to control the INS AX2 simulator remotely from your PC  To be free  from the EM interference from the simulator  an optical fiber cable and conversion adapter for your PC are included    amp  Controls INS AX2 via a personal computer    Easily creates and manages tests and sequence of tests     e amp Manual mode test offers static tests  Sweep mode test offers tests at ramped voltages and placement phase angles or  repetition periods  Program mode provides the selected sequence of tests   e Test report generation  preview and printing are available     Test set up Window    All test parameters can be set in this window  In Sweep mode  the order of    parameters to be ramped can be changed  Voltage changes first or either  Phase or Variable changes first     A complete set of all test parameters settings is called    Unit     One unit  can be a Manual test or a Sweep test  In Program test  units can be freely  combined and run according to the user defined sequence     Test run Window    While the Program test is run     units    are listed  The unit currently done is  highlighted for easier identification        BOPTIONAL ACCESSORIES FOR INS AX2 series  mOutlet Panel MODEL 18 00069A    JP USA type  AC125V 20A max    m Outlet Panel MODEL 18 00070A    CEE 7 Schuko type  AC240V 16A max    m Outlet Panel MODEL 18 00071A   Circuit breaker box MODEL 18 00072A       Multi type ko Single phase AC240V 20A 50 60Hz  DC65 20A  AC240V 15A 
15. pulse Noise Simulator           2 series 220 420 250 450    INS AX2 series simulators are the advanced version of the conventional manually operated INS 4020 4040 simulators   maintaining the identical interference signal characteristics while offering a new level of ease of use        SB FEATURES   An innovative  motor driven coaxial switch mechanism eliminates the need to manually plug and unplug coaxial connectors   allowing a preset test sequence to be carried out seamlessly including pulse width and coupling mode changes  automatic  voltage ramp and others      As well as manual control  the simulator can be remote controlled through a fiber optic computer interface  A Windows  control software package is supplied as an included accessory      Floating output    8 pulse widths installed  10ns  50ns  100ns  200ns  400ns  500ns  800ns and 1000ns   Internal switchable terminators     Easily changeable and safety interlocked outlet panel  EUT interface     3 channels EUT fail input    ECONTROL PANEL    Selects the polarity    Places the unit in status to accept the output voltage setting  The  output voltage can also be automatically ramped in the selected  steps     Increment and decrement of the selected parameter     Selects the line  L1 L2 L3 N  to be injected or selects the PULSE  OUT coaxial port        Selects the signal return line     Places the unit in 1 SHOT mode  each time the button is  pressed  a single pulse is generated     Places the unit in status to accept
16. rated in synchronization  with the EUT supply frequency  The phase angle can also be ramped  according to the settings     Places the unit in status to accept the output voltage setting  The output  voltage can also be ramped according to the settings     Places the unit in external trigger mode     Blinks during the test to warn the operator against HV  potential     Starts and stops the test           BE STANDARD ACCESSORIES  Description Quantity  Coaxial cable 02 00013A 8 30cm length  SG short plug 02 00106A 1  Outlet panel 18 00061B AC240V 16A DC60V 16A maximum     Terminal block type     Instruction manual       Leaves the factory with this panel attached to the Main unit              Impulse Noise Simulator       FH  niceken  ma   Ea   SS m       INS 4020 and 4040  BINS 4020 4040 SPECIFICATIONS    Parameters INS 4020    INS 4040                                     GR a 0 01 2 00kV  10  with 509 Load 0 01 4 00kV  10  with 509 Load   gt  g   0 04KV for  lt 0 1kV    0 04KV for  lt 0 1kV   Polarity Positive or negative  Puce ah 50ns  100ns  200ns  250ns  400ns and any combination thereof  maximum width 1 us   or 10ns 3ns  the shortest  connection   Square  wave Rise time  lt 1ns  Output impetance 500 system  53 50   PHASE 50 or 60Hz  Injection phase angle 0 359   Synchronized with L1  L2 of power supply to be injected  or external terminal    Pulse VARIABLE 10ms   999ms  10  16ms   999ms  10   repetition ayer  gt 10ms  gt 16ms  mode TTL Open collector negative logic TTL Ope
    