Home

condair aBs3

image

Contents

1. Installation Power supply 230V 50 60Hz or 115V 50 60Hz Connection of power supply to terminals L1 and N according to the wiring diagram The service switch Q2 disconnects all 2 wires with a minimum contact clearance of 3 mm and the fuses F2 2 5 A slow acting are mandatory Cable section according to the applicable local regulations Before connecting the power supply cable make sure the local mains voltage meet the value stated on the rating plate of the Condair ABS3 External humidity controller A1 or external On Off humidistat A2 Connect the external humidity controller 0 10V to terminals IN and GND or connect the external On Off humidistat to terminals IN and 24V Note In locations with electromagnetic interferences use shielded connecting cables Maximum humidistat A3 not mandatory Connect the switching contact of the maximum humidistat to supply line L1 according to the wiring diagram Required contact load 230V 2A or 115V 4A Note In order to connect the mains cable and the cable of the external humidistat humidity control ler to the control board the electric connection box in the unit must be dismounted and opened For this purpose please observe the notes in chapter 4 4 3 and the notes regarding the cabling in chapter 4 4 4 4 4 3 19 Dismounting and mounting the electric connection box Dismounting the electric connection box 1 Undo the three screws at the air fi
2. S2 e SSI Sey xy 4 V O Be WV d We 7 XX VM L V V d Weide Oh WV Wi Ku V VW dc yy ec WV VO Ach AAA A dei V V V V AAA Wd Weld XY Wy Ke V X D d WV n A de WV V A A ee SS SS ee CSS EE EE eeng EE 1 Undo the three screws and remove the air filter assembly downwards Clean filter mat on both sides with a vacuum cleaner Place the cleaned filter mat between the two filter grids then insert the filter assembly from downside into the unit and fix it with the three screws Note If the filter mat is heavily contaminated replace the filter mat EU3 C3 1 Undo the three screws and remove the air filter assembly downwards 2 Remove pipe B from the connector Undo the two screws C then remove the connection piece A from the siphon Clean siphon and connection piece 5 Assemble the unit in reverse order of steps 1 4 Remove supply pipe A Pull the sieve out of the inlet valve Clean the sieve Insert the sieve into the inlet valve OO NN Re connect supply pipe A and tighten union nut by hand Note If the sieve must be cleaned often a water filter should be installed in the water supply line see chapter 4 3 1 26 Troubleshooting 7 1 7 2 Important notes on troubleshooting Qualification of personnel Have faults eliminated by ad
3. Notes on water quality For the water supply of the Condair ABS3 use exclusively untreated drinking water or fully demineralised water The use of additives such as corrosion inhibitors disinfectants etc is not allowed since these additives may endanger health and affect proper operation The connection material must be pressure proof and certified for use in drinking water systems Important Before connecting the water line the line should be well flushed out The thread at the humidifier connection is made of plastic To avoid overtightening the union nut of the water pipe must be tightened by hand only Water drain The water drain is to be carried out according to the figure found in chapter 4 3 1 and the applicable local regulations for water installations The indicated connection specifications must be observed Make sure that the drain line is routed with a constant downward slope gt 10 to the drain funnel of the building Important The drain pipe must be prevented from sagging support with brackets if neces sary Make sure that the minimum inside diameter of 10 mm is maintained throughout the entire length of the drain pipe and that the pipe is not kinked Make sure that the drain pipe is correctly fixed and easily accessible for inspections and cleaning purposes When operating the Condair ABS3 with fully demineralised water Fully demineralised water is aggressive For this reason us
4. These installation and operating instructions are available in various languages Please contact your Condair supplier for information Copyright protection The present installation and operating instructions is protected under the Copyright Act Passing on and reproduction of the manual or part thereof as well as exploitation and communication of the contents are prohibited without written permission by the manufacturer Violation of copyright terms is subject to legal prosecution and arises liability for indemnification The manufacturer reserves the right to fully exploit commercial patent rights For your safety General Every person working with the Condair ABS3 must have read and understood the installation and operating instructions before carrying out any work Knowing and understanding the contents of the installation and operating instructions is a basic requirement for protecting the personnel against any kind of danger to prevent faulty operation and to operate the unit safely and correctly All ideograms signs and markings applied to the unit must be observed and kept in readable state Qualification of personnel All work installation operating servicing etc described in these installation and operating instruc tions may only be carried out by specialist who are well trained and adequately qualified and are authorized by the customer For safety and warranty reasons any action beyond the scope of this manu
5. 55 416 61 11 Fax 41 55 416 62 62 info condair com www condair com
6. too large Contact Condair dealer Suction tube of atomiser unit blocked Check suction cone Clean if nec essary The atomiser runs noisily Atomiser assembly not correctly installed Check atomiser assembly Mount parts correctly Suction cone has become undone Tighten the suction cone Taking out of service Disposal 27 8 1 8 2 Taking out of service If the Condair ABS3 must be replaced or if the humidification system is not needed any more pro ceed as follows 1 Take the unit out of operation as described in chapter 5 3 2 Have the unit and all other system components if necessary unmounted by a qualified service technician Disposal Recycling In conformance with the European Directive 2002 96 EC on Waste Electrical and Elec tronic Equipment WEEE this device may not be disposed of in domestic waste This also applies to countries outside the EU per their specific requirements Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this device Should this unit be passed on to other parties for private or professional use the content of this regulation must also be related Thank you for your contribution to environmental protection 9 Product specification
7. wall using the wall bracket as template Make sure the wall bracket is aligned exactly horizontal before marking the holes 2 Drill the four fixing holes 28 mm 45mm deep 3 Clean the holes and insert the dowels 4 Fix the wall bracket with four screws to the wall position of the bracket as shown in the figure above Before tightening the screws align the wall bracket exactly horizontal Mounting the unit Lift the unit above the wall bracket and swivel it slightly towards the wall Move the unit towards the wall into the wall bracket Swivel the unit to the horizontal position until both brackets are perfectly coupled Aa OO N Secure the unit in the wall bracket with the safety screw M6x20 and the washer 6x12 supplied mandatory 4 2 3 Ceiling mounting hanging installation Ceiling mounting is done with the angle brackets supplied as standard The three chains for hanging up the unit must be provided by the customer The chains must be fixed at the ceiling exactly perpendicularly above the three angle brackets fixed to the unit The fixing points and the chains must have a sufficient load bearing capacity in order to carry the weight of the unit see chapter 9 1 Technical data Use chains made of steel preferably corrosion resistant steel The dimension of the chain links must meet to the specifications in the adjacent figure 1 Undo the 4 screws V and remove the mounting p
8. Condair ABS3 Adiabatic Atomiser Humidifier Jair ABS3 INSTALLATION AND OPERATING INSTRUCTIONS 2546634 EN 1112 N co ndair Contents 1 1 1 2 3 3 1 3 2 3 3 3 4 3 5 3 6 4 41 42 4 2 1 4 2 2 4 2 3 43 4 3 1 4 3 2 44 44 1 44 2 44 3 444 445 Introduction To the very beginning Notes on the installation and operating instructions For your safety Product overview Unit construction Principle of operation Identification of the unit Accessories and options Standard delivery Storing Transportation Packaging Mounting and installation work Important notes for mounting and installation work Mounting the unit Notes on unit location Wall mounting Ceiling mounting hanging installation Water installation Overview water installation Notes on water installation Electric installation Wiring diagram Condair ABS3 Notes on electric installation Dismounting and mounting the electric connection box Notes regarding the cabling Configuration 4 4 5 1 Setting the flushing cycles 4 4 5 2 Setting the humidification capacity limitation 5 1 5 2 5 3 6 1 6 2 6 3 7 1 7 2 8 1 8 2 9 1 9 3 Operation Setting the unit into operation Inspections during operation Taking the unit out of operation Maintenance Important notes on maintenance Maintenance intervals Maintenance work Troubleshooting Important notes on troubleshooting Malfunction list Taking out of service
9. Disposal Taking out of service Disposal Recycling Product specifications Technical data Dimensions Declaration of conformity 22 22 22 23 24 24 24 25 26 26 26 27 27 27 28 28 28 29 Introduction 1 1 1 2 To the very beginning We thank you for having purchased the adiabatic atomiser humidifier Condair ABS3 The Condair ABS3 incorporates the latest technical advances and meets all recognized safety standards Nevertheless improper use of the adiabatic air humidifier Condair ABS3 may result in danger to the user or third parties and or impairment of material assets To ensure a Safe proper and economical operation of the Condair ABS3 please observe and comply with all information and safety instructions contained in the present installation and operating instruc tions as well as in the separate documentations of the components installed in the humidification system If you have questions which are not or insufficiently answered in this documentation please contact your Condair supplier They will be glad to assist you Notes on the installation and operating instructions Limitation The subject of these installation and operating instructions is the adiabatic atomiser humidifier Condair ABS3 The various accessories are only described insofar as this is necessary for proper operation of the equipment Further information on accessories can be obtained in the respective instructions These install
10. Operation 5 1 5 2 Setting the unit into operation Proceed as follows when putting the Condair ABS3 into operation 1 Check the Condair ABS3 and the installations for possible damage Adamaged unit or an unit with damaged installation may present danger to human life or cause severe damage to material assets A damaged unit and or an unit with damaged or faulty installation must not be oper ated 2 Make sure that the electric connection box is closed correctly set in the receptacle of the unit and secured and that the air filter assembly is correctly mounted and fastened 3 Open the stop valve of the water supply line and check water system for leakages An unit with leakages must not be operated 4 If necessary turn outlet openings of the diffusor into the desired blow out direction 5 Verify the set humidity value at the external humidity controller numidistat and readjust as re quired 6 Turn on the service switch in the mains supply line The unit performs a flushing cycle which takes approx 1 minute Then the unit is ready for op eration As soon as the external humidity controller or the humidistat requires humidity the motor starts and the atomisation begins Inspections during operation During operation the Condair ABS3 and the humidification system have to be inspected weekly On this occasion check the following e the water installation for any leakage e the humidifier and the other s
11. al must be carried out only by qualified personnel authorised by the manufacturer It is assumed that all persons working with the Condair ABS3 are familiar and comply with the ap propriate regulations on work safety and the prevention of accidents Intended use The adiabatic atomiser humidifier Condair ABS3 are intended exclusively for air humidification within the specified operating conditions see chapter 9 Product specifications Any other type of application without the written consent of your Condair supplier is considered as not conforming with the intended purpose and may lead to the Condair ABS3 becoming dangerous Operation of the equipment in the intended manner requires that all the information in these in structions are observed in particular the safety instructions Danger that may arise from the unit One may get in touch with live parts when the wiring box is open Touching live parts may cause severe injury or danger to life Prevention before carrying out any work set the Condair ABS3 out of operation as described in chapter 5 4 switch off the unit disconnect it from the mains and stop the water supply and secure the unit against inadvertent power up Badly maintained humidifiers can endanger the health If the unit is insufficient maintained ill making germs may grow in the water reservoir of the Condair ABS3 and may can affect the air passing through the humidifier Prevention the Condair ABS3 must b
12. ar racks machines supports etc will result in stagnation and the formation of turbulence which could cause condensation Since the discharge hood of the humidifier can be turned horizontally the aerosol stream can be directed to bypass any obstruc tions In the following table you find the minimum distances appoximate values which must be maintained when positioning the Condair ABS3 The dimensions relate to a room temperature of 20 C and arelative humidity of 45 At lower temperatures and or higher relative humidity larger minimum distances must be maintained Wall mounting Ceiling mounting Minimum distance in m gt 3 0 21 0 21 5 21 0 25 0 Mountthe unit such that there is sufficient room for maintenance Also make sure that the unit is readily accessible and that there is no accident risk during maintenance Ifunits are to be installed facing each other make sure that they are at least 10 m apart Insulate cold water piping in the vicinity of the aerosol stream risk of condensation The evaporation process extracts heat from the ambient air Make sure therefore that the aerosol stream is not directed at persons 4 2 2 13 Wall mounting To fix the humidifier to the wall use the wall bracket screws and dowels provided The wall bracket can be used as template for the fixing holes Mounting the wall bracket P o B 1 Mark the fixing holes on the
13. ation and operating instructions are restricted to the installation commissioning operation servicing and trouble shooting of the Condair ABS3 and is meant for well trained personnel being sufficiently qualified for their respective work The installation and operating instructions are supplemented by various separate items of docu mentation Where necessary appropriate cross references are made to these publications in the installation and operating instructions Symbols used in this manual The catchword CAUTION designates notes in this installation and operating instructions that if neglected may cause damage and or malfunction of the unit or other material assets The catchword WARNING used in conjunction with the general caution symbol designates safety and danger notes in this installation and operating instructions that if neglected may cause to injury to persons The catchword DANGER used in conjunction with the general caution symbol designates safety and danger notes in this installation and operating instructions that if neglected may lead to severe injury or even death of persons Safekeeping Please safeguard these installation and operating instructions in a safe place where they can be immediately accessed If the equipment changes hands the documentation must be passed on to the new operator If the documentation gets mislaid please contact your Condair supplier Language versions
14. be followed and complied with Observe and comply with all local regulations dealing with water and electrical installations When installing individual components use the fixing materials supplied with the unit If fixing with the materials supplied is not possible in your particular case select a method of fixing that is of similar stability In case of doubt please contact your Condair supplier The connection of the water supply pipe and the water drain pipe on the unit see chapter 4 3 as well as the connection of the main cable and the cable of the external humidistat numidity controller in the unit see chapter 4 4 can be done before the unit is mounted to the wall ceiling 4 2 4 2 1 Mounting the unit Notes on unit location In order to ensure the correct function of the humidifier and the accessibility for maintenance please observe the following locating instructions TheCondairABS3 humidifiers are designed for wall mouting or ceiling mounting hanging instal lation Make sure that the structure wall pillar ceiling etc on which the unit is to be mounted has sufficient carrying capacity and can accommodate the fastening elements In order to ensure the correct function the Condair ABS3 must be installed exactly horizontal with the air filter facing downward against the floor Locate the unit such that the aerosol stream can spread freely The obstruction of the aerosol stream by objects such as tubul
15. e cleaned in the prescribed intervals according to the infor mation given in chapter 6 Maintenance The cleaning works must be carried out correctly and the air filter must be replaced after their prescribed lifetime has elapsed Behaviour in case of danger If it is suspected that safe operation is no longer possible then the Condair ABS3 should imme diately be shut down and secured against accidental power up according to chapter 5 4 This can be the case under the following circumstances if the Condair ABS3 is damaged if the Condair ABS3 is no longer operating correctly if connections and or piping are not sealed if electrical cables are defective if the Condair ABS3 is no longer fastened correctly All persons working with the Condair ABS3 must report any alterations to the unit that may affect safety to the owner without delay Prohibited modifications to the unit No modifications must be undertaken on the Condair ABS3 without the express written consent of the manufacturer For the replacement of defective components use exclusively original accessories and spare parts available from your Condair supplier A Product overview 3 1 3 2 Unit construction 1 Air filter EU3 C3 8 Atomiser collar 2 Electrical connection box 9 Water supply 3 Water reservoir 10 Level switch 4 Cone with fan 11 Water drain 5 Atomiser disk 12 Siphon 6 Motor 13 Unit housing 7 Discharg
16. e exclusively installation material made of corrosion resistant steel min DIN 1 4301 or plastic 4 4 Electric installation 4 4 1 Wiring diagram Condair ABS3 Eh ES SS SS SSH NTC GND IN 24V LEVEL N L1 Ki KR K s1 D 82 i H1 X lt Y1 E HE H LLL L external Es ON OFF oar ie J Q2 wl ON OFF F2 115 V 50 60Hz 230 V 50 60Hz A1 A3 S1 S2 H1 F1 F2 Q2 Sw SW2 Y1 F1 GE swi Off On DI Ea G SW2 o jojojojo 10 24 VDC 60 mA 1 1 I h Continuous humidity controller 0 10 V On Off humidistat Maximum humidistat not mandatory required contact load 230V 2A or 115V 4A Temperature sensor to switch the optional heating H1 on and off Level switch Heating option anti freeze kit Internal fuse transformer 315 mA slow acting External fuse voltage supply 2 5 A slow acting Fan motor External service switch with a minimum contact clearance of 3 mm DIP switches for setting the flushing cycles Rotary switch for setting the power limit Inlet valve 17 4 4 2 Notes on electric installation The electric installation must be carried out according to the wiring diagram in chapter 4 4 1 and the applicable local regulations All information given in the wiring diagram must be followed and observed The electrical installation of the Condair ABS3 includes
17. e hood rotatable Principle of operation The Condair ABS3 operates according to the atomization principle The water is drawn in through cone 4 from the water reservoir 3 and is hurled from the atomiser disk 5 against the atomiser collar 8 thereby producing aerosols fog The level in the water res ervoir is monitored and controlled with the float switch 10 The fan attached to the cone draws in room air through the air filter 1 on the bottom of the base unit This air transports the aerosols to the atomiser outlet 7 and distributes them in the room The humidifier is controlled via an external On Off humidistat or an external 0 10V continuous humid ity controller which opens and closes the inlet valve When controlled via the external continuous humidity controller the inlet valve is opened and closed cyclically depending on the control signal 3 3 3 4 Identification of the unit The indication of the unit as well as the most important unit data are found on the type plate ondair Type designation Zerstauber F3003 Outlet angle in degrees Unit voltage Sm Condair ABS3 120 230V CE Unit voltage power consumption Serial number He pea 3 249976 930 Ve 5060 Hz 230W 300W aru Q 9 TIOUN 08 S01776 00001 Month Year Approval symbols Accessories and options Accessories Designation Code Description Filter val
18. equately qualified and trained personnel only Malfunctions caused by the electrical installation must be repaired by authorized personnel e g electrician only Repair work and the replacement of defective parts may only be carried out by your Condair repre sentative s service technician Safety In order to eliminate faults the Condair ABS3 must be set out of operation as described in chapter 5 3 disconnect the unit from the mains and secure the unit against inadvertent power up Malfunction list Important Most operational malfunctions are not caused by faulty equipment but rather by improper installation Therefore a complete fault diagnosis always involves a thorough examination of the entire system Malfunction The atomiser does not run al though the service switch in the mains supply line is switched on Cause The current humidity in the room is higher than the set reference humidity value Remedy None wait Fuse F2 in the mains supply line defective Check replace fuse F2 The atomiser keeps running and cannot be switched off by reducing the reference humid ity value Air humidity very low lt 45 rh None wait External humidity controller humidistat defective Check replace external humidity controller humidistat The set reference humidity value is not reached The atomiser runs continuously Air filters heavily contaminated Clean air filter Room
19. erify proper qualification of the personnel General note The instructions and details for maintenance work must be followed and upheld Only the maintenance work described in this documentation may be carried out Only use original Condair spare parts to replace faulty parts Safety Before maintenance is initiated the Condair ABS3 must be taken out of operation in accord ance with instructions in chapter 5 3 and protected against unintentional switching on If the Condair ABS3 is insufficiently maintained ill making germs can increase in the water reservoir by the time and get into the ambient air Maintenance intervals In order to maintain operational safety the Condair ABS3 must be maintained in regular intervals The time interval for the maintenance is to be adapted to the operating conditions The hygiene status depends mainly on the quality of the humidifier water and the micro biological and chemical composition of the supply air Therefore the maintenance intervals must be determined for each system separately The first visual check must be carried out after 200 operating hours Depending on the en countered hygiene status during this first check the maintenance interval time must be decreased or increased In any case the Condair ABS3 is to be maintained however at least twice annually 6 3 Maintenance work Component Work to be carried out Air filter EE Sj RSLS LSLS SLS LSSR lt 2s gt GE
20. he Walter Meier Group Talstrasse 35 37 8808 Pfaffikon Switzerland Tel 41 55 416 61 11 Fax 41 55 416 62 62 info condair com www condair com 29 t condair EC Declaration of conformity D claration de conformit We Condair Ltd CH 8808 Pf ffikon SZ declare under our sole responsibility that the product Nous Condair SA CH 8808 Pfaffikon SZ d clarons sous notre seule responsabilit que le produit Condair ABS3 to which this declaration relates is in conformity with the following standards or other normative standards auquel se r f re cette d claration est conforme aux normes ou autres documents normatifs EN 61000 6 2 EN 61000 6 3 EN 60335 1 EN 60335 2 98 and is corresponding to the following provisions of directives et est conforme aux dispositions des directives suivantes 2006 95 EC 2004 108 EC Notes Condair Ltd Printed in Switzerland Technical modifications reserved CONSULTING SALES AND SERVICE Co 7 SGS Reg No 40002 2 Manufacturer Condair Ltd Member of the Walter Meier Group Talstrasse 35 37 8808 Pf ffikon Switzerland Ph 41
21. ith the cable straps provided to the existing cables at the places marked with ar rows Finally tighten the four cable glands 115 V 50 60Hz ON OFF 230 V 50 60Hz 230 V 50 60Hz A2 115 V 50 60Hz Se LI A1 A2 13431 A z NON OLN 1 1 D 21 ge HILL Ee a F E Be a 0S S x i g 15 a S le E 5 il D H uO HO LMS ld 21 4 4 5 Configuration For the configuration the electric connection box in the unit must be dismounted and opened For this purpose please observe the notes in chapter 4 4 3 4 4 5 1 Setting the flushing cycles The flushing cycles are set via the DIP switches SW1 on the control board SW1 SW1 On Off ul 1 During operation a flushing cycle The 6 hours flushing cycle during is performed every 6 hours operation is deactivated e g for the operation with fully deminer alised water 2 After 72 hours without humidity 72 hours flushing deactivated demand a flushing cycle is per formed before the next humidifi cation cycle 4 4 5 2 Setting the humidification capacity limitation sw2 The humidification capacity limitation is set via the rotary switch SW2 on the 50 control board A Setting range O 1 1 I h 100 6 5 I h RI N wax Factory setting 100 6 5 I h 6 5 l h ER
22. late A on the backside of the unit Note Store the mounting plate A for a possible later use Now you have 5 screws with washers 4 from the just removed mounting plate and the safety screw provided Refit two of the screws and washers into the fixing holes EE 2 Fix the three angle brackets for hanging installation with the screws and washers to the unit as shown in the adjacent figure 3 Hook the unit with the angle brackets into the chains and check again that the device hangs exactly horizontal 4 3 4 3 1 Water installation Overview water installation A Water supply pipe included in the delivery L 1 5 m G 3 4 B Stop valve by client C Water filter accessory Z261 installation recommended by client D Drain pipe included in the delivery L 1 5 m with constant downward slope gt 10 E Open drain funnel with siphon by client Connector water supply G 3 4 Connector water drain 210 mm Water supply pipe Drain pipe 012 10 mm 15 4 3 2 Notes on water installation Water supply The water supply is to be carried out according to the figure found in chapter 4 3 1 and the applicable local regulations for water installations The indicated connection specifications must be observed The installation of a stop valve mandatory and a water filter accessory Z261 installation recommended should be made as close as possible to the unit
23. lter assembly and remove the air filter assembly 2 Push fixing clip C sidewards and carefully pull connection box out of the unit 3 Undo the four screws of the connection box and remove the cover Now you can connect the cables on the control board or configure the control The electronic components inside the electric connection box are very sensitive to electro static discharge When the unit is open for installation work appropriate measures must be taken to protect these components against damage caused by electrostatic discharge ESD protection Mounting the electric connection box 1 Re attach the cover of the connection box and fix it with the four screws 2 Replace the connection box into the receptacle in the unit and fix it with the fixing clip 3 Set the air filter assembly grid filter grid into the bottom of the unit an fix it with the three screws 20 4 4 4 Notes regarding the cabling 1b 2b 1a 2a Pass the power supply cable through the cable gland 1a into the unit and through the cable gland 1b into the electric connection box and connect it to the control board according to the wiring dia gram Pass the cable of the external controller humidistat through the cable gland 2a into the unit and through the cable gland 2b into the electric connection box and connect it to the control board ac cording to the wiring diagram Fix both cables w
24. s 9 1 Technical data Humidification capacity 1 1 6 5 I h Unit voltage 230V 50 60Hz or 115V 50 60Hz Power consumption 0 23 KW 0 3 KW with optional anti freeze kit Air circulation 280 m h 77 8 I s Content water reservoir 0 055 Unit weight 17 6 kg Connector water supply R 3 4 outside thread Connector water drain 10 mm Admissible pressure water supply 1 10 bar 0 1 1 0 MPa Admissible temperature water supply 5 45 C Water quality Tap water or fully demineralised water Admissible operation temperature humidity 2 35 C 0 lt 100 rh Admissible operation temperature humidity 2 35 C 0 lt 100 rh with optional anti freeze kit Admissible storage temperature humidity 10 60 C 0 80 rh Type of protection IPX4 Conformity CE mark non condensing 9 2 Dimensions 120 version Dimensions in mm 565 505 530 610 Dimensions in mm 565 505 530 2546297 DE EN FR 1201 Konformitatserklarung Wir Condair AG CH 8808 Pfaffikon SZ erklaren in alleiniger Verantwortung dass das Produkt auf das sich diese Erklarung bezieht mit den folgenden Normen oder normativen Dokumenten bereinstimmt und den Bestimmungen der folgenden Richtlinien entspricht Pf ffikon January 01 2012 Condair Ltd Te Thomas Gr tter Head of Development Condair Ltd Member of t
25. ternal diameter 10 mm 2 pcs cable straps Spare parts list Storing Transportation Packaging Storing Store the unit in the original packaging in a protected area meeting the following requirements Room temperature 1 40 C Room humidity 10 75 rh Transportation For optimum protection always transport the unit in the original packaging If possible always transport the unit with the help of another person Packaging Keep the original packaging of the Condair ABS3 for later use In case you wish to dispose of the packaging observe the local regulations on waste disposal Never dispose of the packaging to the environment Mounting and installation work 11 4 1 Important notes for mounting and installation work Qualification of personnel All mounting and installation work must be carried out only by well qualified personnel which is familiar with the Condair ABS3 All work concerning the electric installation must be performed only by adequately qualified personnel electrician or workman with equivalent training Safety The Condair ABS3 may be connected to electric mains only after all installation work has been completed The local regulations relating job safety must be followed and complied with for all installation and mounting work General notes All statements relating to the positioning and installation of the ABS3 as well as to the water and electrical installation must
26. ve Z261 Filter valve with G 1 2 internal thread connectors for the installation in the water supply line Room humidistat HSC On Off room humidistat Room humidistat H5 H5V On Off room humidistat Note this humidistat can be used as a maximum humidistat Room humidity controller RCC 0 10 V continuous humidity controller with sensor Options Designation Code Description Anti freeze kit AFP Anti freeze kit for the operation of the Condair ABS3 up to a temperature of 2 C The anti freeze kit consist of a heating element connected to the con trol board The Condair ABS3 is prepared for the installation of the anti freeze kit The control of the heating element is established via the temperature sensor built into the unit The temperature sensor switches the heating element on if the ambient tem perature drops below 1 C 3 5 3 6 Standard delivery The standard delivery includes Adiabatic atomiser humidifier ABS3 with options according delivery note Ordered accessories with operating instructions packed separately Installation and operating instructions this document Fixing set for the wall mounting of the unit 1 pc wall bracket 4 screws with dowels 38 mm 1 pc safety screw M6x20 with washer 6x12 Fixing set for the hanging installation 3 pcs angle brackets Water supply pipe L 1 5 m with G 3 4 union nuts Adapter G 1 2 G 3 4 Water drain pipe L 1 5 m in
27. ystem components for correct fixing and any damage e the electric installation for any damage If the inspection reveals any irregularities e g leakage irregular running or any damaged compo nents take the Condair ABS3 out of operation as described in chapter 5 3 Then let the damage or malfunction be resolved by a qualified specialist or a service technician of your Condair supplier Note During operation individual drops are carried along by the air flow and thrown against the hood This causes an audible noise which is completely normal 5 3 Taking the unit out of operation Proceed a follows to put the Condair ABS3 out of operation e g for maintenance work elimination of a malfunction 1 Ifthe Condair ABS3 humidifies right now Set the humidity reference value on the external humid ity controller humidistat to 0 rh and wait until the unit has finished the flushing cycle approx 1 minute 2 Turn off the service switch in the mains supply line then secure the service switch against inad vertent switching on 3 Close the stop valve of the water supply line Note If the Condair ABS3 is not used for prolonged period of time cover the unit with a plastic hood 23 24 Maintenance 6 1 6 2 Important notes on maintenance Qualification of personnel All maintenance work must be carried out only by well qualified and trained personnel authorised by the owner It is the owner s responsibility to v