Home

SCO Operating System support of hp StorageWorks Modular Smart

image

Contents

1. QLogic QLA2300 B T L RAID COMPAQ MSA1000 4 94 B T L DISK COMPAQ MSA1000 VOLUME 4 94 Where C the Controller B the Bus T the Target L the Logical Unit Number N the instance assigned by the qle2300 driver to each HBA A typical output of this command with the MSA1000 attached sdiconfig I 0 0 31 0 HBA _ ciss 1 hp ProLiant CISS 0 0 0 DISK HP LOGICAL VOLUME 2 58 1 31 0 HBA ciss 1 hp ProLiant CISS 2 31 0 HBA ciss 1 hp ProLiant CISS 1 0 2 0 HBA _ ide 1 Generic IDE ATAPI 0 0 0 CDROM COMPAQ CD 224E A 8D 3 0 7 0 HBA qlc2300 1 Qlogic QLA2300 HBA 0 0 0 RAID COMPAQ MSAI1000 4 94 Controller 0 0 1 DISK COMPAQ MSA1000 VOLUME 4 94 LUNT 0 0 2 DISK COMPAQ MSA1000 VOLUME 4 94 LUN2 0 0 3 DISK COMPAQ MSA1000 VOLUME 4 94 LUN3 1 7 0 HBA qlc2300 1 Qlogic QLA2300 2 7 0 HBA qlc2300 1 Qlogic QLA2300 3 7 0 HBA qlc2300 1 Qlogic QLA2300 4 7 0 HBA qlc2300 1 QLogic QLA2300 5 7 0 HBA qlc2300 1 Qlogic QLA2300 6 7 0 HBA qlc2300 1 Qlogic QLA2300 7 7 0 HBA qlc2300 1 Qlogic QLA2300 SCO UnixWare7 diskadd command could be used to add the missing configured MSA1000 LUNs that are not listed by the sdiconfig command Using SCO UnixWare7 fdisk command one can create and modify the LUN partition table Typical usage of this command is fdisk dev rdsk cCbBtTdDsO Using SCO UnixWare7 disk
2. with the key components identified MSA1000 Front View MSA1000 Rear View Reference Identifier Reference Identifier Redundant Controller Slot Blank 2 Gb Small Form Factor Pluggable SFP Transceiver Primary MSA1000 Controller Fibre Channel I O Module Redundant Fibre Channel I O Display Buttons Module Slot Blank Display Panel Power Supply Indicators Blowers Attached to Power Display Indicators Supply Status Indicators SCSI Expansion Port A Power Switch SCSI Expansion Port B Environmental Monitoring Unit Indicators Oo N I O ON BI WwW ND Power Bay s SO GON W NF BR UI N Environmental Monitoring Unit MSA30 The MSA30 provides scalability and performance at a reduced aaa cost with a high return on investment and with the ability to amaw TTT manage more data with less staffing and increased computing y infrastructure utilization for better overall system performance Key features of the MSA30 e Affordable capacity e Easy deployment e Investment protection e Increases storage density when used with MSA1000 and MSA1500 MSA30 Overview The HP StorageWorks Modular Smart Array 30 Enclosure family is the newest HP Ultra320 SCSI disk drive storage enclosure delivering industry leading data performance availability storage capacity and upgradeability to meet the demanding and growing storage needs The MSA30 Enc
3. 20 P N 335921 B21 Firmware Version 1 28 4 HP StorageWorks Modular Smart Array 30 P N 302969 B21 Firmware Version CP20 Software Listed below are the software requirements to support MSA1000 and MSA1500 unless noted Operating System HP EFS 1 SCO OpenServer 6 0 0 hp ProLiant Extended Feature Supplement EFS for SCO UnixWare 7 and SCO OpenServer 6 version 7 70A 2 SCO UnixWare 7 1 3 The latest ProLiant Ext Feat l ti 3 SCO UnixWare 7 1 4 e latest ProLian xtended Feature Supplement is available at Use the latest Maintenance Pack available at http h18004 www1 hp com support files server us d hitp www sco com support download html ownload 23643 html Configuring MSA1000 amp MSA1500 MSA1000 amp MSA1500 ship with a CD containing HP Array Configuration Utility ACU The HP Array Configuration Utility software for Smart Array controllers and the StorageWorks Enclosure products makes it easy to configure and expan d your disk drive arrays NOTE SCO Operating Systems do not support online ACU MSA1000 amp MSA1500 can also be configured using Command Line Utility CLI from a Windows box For more information on CLI setup and usage refer to the CLI user guide available at h20000 www2 hp com be docs support SupportManual c00149849 c00149849 pdf http MSA Deployment Deploying the MSA1000 MSA1500 in a SCO Operating System environment involves Place a
4. operating system unless noted ProLiant servers ProLiant servers 1 DL380 G3 8 ML350 G4p 2 DL380 G4 9 ML370 G3 3 DL380 G4 SAS 10 ML370 G4 4 DL580 G2 11 ML530 G2 5 DL580 G3 12 ML570 G2 6 DL760 G2 13 ML570 G3 7 ML350 G4 Host Bus Adapter Host Bus Driver 1 HP StorageWorks FCA2214 P N 281541 B21 qlc2300 Qlogic QLC2300 Fibre Channel HBA Driver 2 HP StorageWorks FCA2214DC P N 321835 B21 Use the driver available on the OS media or download the latest version from FCA2214 FCA2214DC is 2 Gbps Fibre Channel to hip wiw sea com suppoit dowaload htimi PCI X Host Bus Adapter that provides operating system connectivity support for the HP StorageWorks storage array family HBA is branded and marketed under different names Use the latest BIOS for HBA available at www hp com NOTE hp Proliant Servers recognize FCA2214 and FCA2214DC controllers in the following way a At POST QLA2312 PCI Fibre Channel b In RBSU Qlogic 2340 2342 64Bit 133MHz PCI X to FC 2GB HBA Storage Connectivity requirements 1 HP StorageWorks Modular Smart Array 1500 cs 1 HP MSA SAN Switch 2 8 P N 288247 B21 PAN EOE ON 2 HP MSA Hub 2 3 P N 286763821 3 StorageWorks Fibre channel Storage Hub 12 2 HP StorageWorks Modular Smart Array 1000 P N 295573 001 PAN 201723822 4 Brocade Silkworm 2040 SAN switch Firmware Version 4 96b Firmware Version 4 94 3 HP StorageWorks Modular Smart Array
5. 4 Configuring MSA LUNs in SCO Operating System c ccccccsccessceesceeseecseecseecseecseeesaeecseecsseesaeeneenseenseeens 15 LIMITATIONS TE E E E A E E E faauiavaerticonss dates 16 For more information ccccccccccccessesssseccsccececsessssescccesseesessssesceseeseesssausescessessestssssceccesesntnssseceseeeeentavess 17 MSA1500 The MSA1500 provides scalability and performance at a reduced cost with a high return on investment and with the ability to manage more data with less staffing and increased computing infrastructure utilization for better overall system performance Key features of the MSA1500 MSA1500 with MSA30 ond MSA20 enclosure e Low cost highest scalability capacity supports MSA20 amp MSA30 e Both SCSI and SATA drive support e Easy management MSA1500 Overview The HP StorageWorks 1500cs Modular Smart Array MSA1500 is a Fibre Channel storage area network SAN 2U controller shelf that connects to HP StorageWorks Serial ATA SATA and or SCSI disk enclosures They provide customers with a flexible low cost high capacity storage solution The MSA1500cs has been designed as a hardware foundation for future solutions to ensure maximum investment protection The MSA1500cs is perfect for those customers looking for less expensive storage solutions using HP SATA enclosures to store data that doesn t require a high degree of I O performance and or is viewed as non mission critical to business operations The MSA1500cs
6. SCO Operating System support of hp StorageWorks Modular Smart Array Table of Contents IMSAT SOQ cs cecicthacwsasefesic esshesandeosshed aseduavsauesiatiasbedannesasaddan secaasaeshoca cissevdawiceauvs Eae NERE AEE AEAEE aae 2 MSAT O00 sonsir e caeshbas cevusbay T EE S EEA EE 4 MSASO O AA E E E 6 MSA20 casts E E tadsnszaceleuaisicd anibdccasassectensaacetcass 7 MSA support for SCO Operating Systems Supported Compoment ccccccccecsseceseesseeeeeeneeseeneeneeeseees 8 HardWare eana aces see A E S E E E E dams teens E ees cgegenteeosteiee a 8 SOWA TE seie E E E E E E a R ES 9 MSA D ployment se aciesseiinencsngea nci iene ranore Eaa AN ERS TAEAE E EREE e Oe AE EE Eei 10 Connecting MSA to ProLiant servers running SCO operating systems cccccccecesessenteceeeeeeesessenneeeeeeeens 10 Figure 1 Single Server Single Path using the Fibre Channel I O Module Direct ceseeteeteeeees 11 Figure 2 A Typical MSA1000 Configuration using MSA SAN Switch 2 8 11 Figure 3 A Typical Configuration with a Server and MSA1000 using MSA Hub 2 3 ceceeeeeeerees 12 Figure 4 A Typical Single Path MSA1500 Configuration cccccccccsscssscssecesecesecenecesseeeseecseeeaseenseenaes 12 Configuring logical volumes on the MSA ccccccccssscsseceseceseceeceeseeeseecseecseecasecseecsaeesseseseeeaeenseesaeenseeees 13 Installing the HBA Drivers issiec ceesacectussnecstenss ianen aE ERAEN T AEAEE EEA AEE E wea soe wuied wees 1
7. checkmark in the box after completing each step Item Comments v Connecting the ProLiant server running SCO operating system Configuring logical volumes on the MSA Installing the HBA driver on the SCO servers Identifying logical volumes to the SCO operating system MSA maintenance Connecting MSA to ProLiant servers running SCO operating systems v Item Comments v Direct Attach Internal Hub Internal switch External switch 10 The following diagrams illustrate these connectivity types Figure 1 Single Server Single Path using the Fibre Channel I O Module Direct 2 8 TE Kia wae Se Figure 3 A Typical Configuration with a Server and MSA1000 using MSA Hub 2 3 Fibre Channel Switch Configuring logical volumes on the MSA The LUNs on MSA1000 MSA1500 can be configured using Command Line Interface CLI or the ACUXE utility Item Comments v Creating LUNs using CLI HP StorageWorks Modular Smart Array MSA Command Line Interface document available at http h20000 www2 hp com bc docs support SupportManual c001498 49 c00149849 pdf provides information to use the Command Line Interface In order to use the CLI interface a serial connection needs to be setup to the MSA1000 MSA1500 controller Refer to the CLI setup section in the Int
8. erface document Create the LUNs as described in the Creating LUNs section in the Interface document Creating LUNs using ACUXE The Array Configuration Utility XE can be used to create the LUNs on a MSA This utility is available on a bootable CD that is shipped with MSA1000 MSA1500 Boot the ProLiant server with the MSA attached using this CD Follow the on screen instructions to create a LUN 13 Installing the HBA Driver v Item Comments v Install the SCO Operating System on a ProLiant server Driver Software Refer to the SCO Operating System Deployment Guide for OS installation tips on ProLiant platforms Update the system with latest Maintenance Pack for OS Install the HP ProLiant Extended Feature Supplement for SCO UnixWare 7 and OpenServer 6 version 7 70A qlc2300 Host Bus Adapter HBA Driver Supplement version 8 0 3 for SCO OpenServer 6 0 0 is available on the SCO OpenServer 6 0 0 installation media For SCO UnixWare 7 1 3 and SCO UnixWare 7 1 4 use the latest version of qlc2300 Host Bus Adapter driver available at hitp www sco com support update download release php rid 25 Creating HBA Diskette In order to create HBA diskette from image hba qlc2300 83a image perform the following steps applicable for SCO UnixWare 7 1 3 7 1 4 only Login as root on a SCO Unix system and perform the following su Password lt type your ro
9. gh performance shared storage Key features of the MSA1000 e Modular design to grow as the needs demand e Enterprise class SCSI storage e Easy migration of existing drives and data e Supports two MSA30 per MSA1000 box e Offers highest level of fault tolerance RAID 6 MSA1000 Overview The HP StorageWorks 1000 Modular Smart Array MSA1000 is a 2 Gb Fibre Channel storage system for the entry level to midrange storage area network SAN It provides the customer with a low cost scalable high performance storage consolidation system with investment protection It is designed to reduce the complexity and risk of SAN deployments The powerful but easy to use management software makes it ideal for departmental and remote location SANs The ability to easily move most data disks and enclosures currently directly attached to Smart Array controllers DAS to a shared storage environment SAN will save the user both money and time With the addition of two more drive enclosures it can control up to 42 drives allowing capacity of twelve terabytes All configuration management and partitioning and licensing software come standard with no extra charges HP s exclusive optional embedded 8 port SAN switch or 3 port hub give cost effective and space saving methods of creating a SAN environment In addition it is qualified on any of the external B series M series and C series FC switches MSA1000 Features Two views of the MISA1000 are shown
10. losure is ideal for data center departmental and workgroup server users who need a flexible universal storage enclosure that utilizes a common storage building block for their current and future data center The MSA30 Enclosure is intended for use with servers delivering business critical data and applications with requirements for high availability performance excellent serviceability and large storage capacity MSA20 The MSA20 provides scalability and performance at a reduced eae cost with a high return on investment and with the ability to manage more data with less staffing and increased computing infrastructure utilization for better overall system performance Key features of the MSA20 MSA20 Overview Affordable capacity Easy deployment Investment protection Increases storage density when used with MSA1500 The HP StorageWorks Modular Smart Array 20 Enclosure MSA20 is a SATA 1 5 Gb s disk drive storage enclosure with Ultra320 SCSI host connectivity These enclosures deliver industry leading availability storage density and upgradeability to meet customers demanding and growing storage needs The MSA20 delivers the ideal mix of low cost and high capacity for minimum I O workloads such as reference data archival and disk to disk backup MSA support for SCO Operating Systems Supported Components Hardware The servers listed below are supported with MSA1000 and MSA1500 on SCO UnixWare and OpenServer
11. nagement support for MSA1000 MSA 1500 16 For more information MSA1500 website at http h18006 www1 hp com roducts storageworks msa 1500cs index html MSA1000 website at http h18006 www1 hp com products storageworks msa1000 index html MSA30 website at http h18004 www 1 hp com products servers proliantstorage sharedstorage sacluster msa30 index html MSA20 website at http h18004 www1 hp com products servers proliantstorage sharedstorage sacluster msa20 in dex html Copyright 2001 2005 Hewlett Packard Development Company L P Hewlett Packard Company makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information which is protected by copyright No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Hewlett Packard The information contained in this document is subject to change without notice UNIX is a registered trademark of The Open Group Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information is provided as is without war
12. ot password gt mkdir tmp hba cd tmp hba Download the hba qlc2300 83a image file to the newly created tmp hba directory on your machine Insert a formatted floppy in to the floppy drive and execute the following command to create qlc2300 diskette from the image file dd if hba qlc2300 83a image of dev dsk fOt bs 36b Installation of HBA Drivers On a SCO UnixWare 7 1 3 7 1 4 system the qlc2300 diskette can be used to install upgrade the qlc2300 driver on your system Insert HBA diskette and execute the command pkgadd d diskette 1 all or pkgadd d diskette qlc2300 On SCO OpenServer 6 0 0 system qlc2300 driver version 8 0 3 available on the OS media can be used to install the driver Insert SCO OpenServer 6 0 0 OS installation media into the CD ROM drive and perform the following 1 Login as root 2 At prompt type the following and press ENTER pkgadd d cdrom qlc2300 14 Configuring MSA LUNs in SCO Operating System v Item Comments v Identifying Logical Volumes to the Operating System To identity the logical volumes configured on MSA1000 MSA1500 login as root on any SCO Unix system with the MSA1000 MSA1500 attached and run sdicontig I This command will list all the Host Bus Adapters MSA1000 MSA1500 controller and the configured LUNs The Qlogic controller MSA1000 and its LUN s will be listed as C B T L HBA qlc2300 N
13. ranty of any kind and is subject to change without notice The warranties for Hewlett Packard Company products are set forth in the express limited warranty statements for such products Nothing herein should be construed as constituting an additional warranty Printed in the U S A 413487 001EN 07 2003 invent
14. setup command the LUNs can be configured to create and mount the file systems disksetup performs the low level activities required to install the primary drive or additional drives The tasks 1S required for disk setup include surface analysis that will assist in creating the layout of slices either through a set of defaults or by asking for details writing the pdinfo VTOC and alternates tables out to the drive issuing needed mkfs calls creating mount points mounting filesystems and updating the etc vfstab file Typical usage of this command is disksetup le dev rdsk cCbBtTdDsO The intended Controller C Bus B Target T and disk D parameters need to be specified appropriately with this command Using SCO OpenServer 6 0 0 mkdev hd one can create filesystems on MSA1000 MSA1500 LUNs mkdev hd presents a list of disks identified on the system running SCO OpenServer 6 0 0 Select the disk to configure and follow the prompts mkdev hd process takes you through fdisk program to create partitions on the selected disk and divvy program to create slices and filesystems on the selected disk Limitations a Oe Ol ee ONS UnixWare 7 OpenServer 6 Maximum of two 2 servers per cluster MSA1000 MSA1500 Redundancy MSA1000 MSA1500 Multipath Online configuration of MSA1000 MSA1500 LUNs Online Firmware upgrade of MSA1000 MSA1500 Event logging of MSA1000 MSA1500 Systems Ma
15. with up to eight attached SATA enclosures can provide the customer with up to 48 TB 96 500 GB SATA disk drives of native capacity If the business needs enterprise class SCSI reliability then attach up to four SCSI enclosures for a native capacity of 16 8 TB using 56 300 GB SCSI disks By using existing SCSI drive enclosures MSA1000 controller technology and integrating low cost SATA hard drives and enclosures the MSA1500cs lowers the total cost of ownership and protects the customer s hardware investments MSA1500 cs Features Two views of the MSA1500 cs are shown with the key components identified MSA1500 cs Front View MSA1500 cs Rear View Reference Identifier Reference Identifier Redundant controller slot blank Reserved for future use Primary Fibre Channel I O 2 Primary controller 2 module 3 Status indicators 3 System information panel 4 Display panel 4 SCSI I O module bus O 5 Display push buttons 5 Power supplies Additional SCSI I O module 6 Power switch 6 lot bus 1 7 Unit ID button and indicator 7 Redundant Fibre Channel I O module slot 8 Fan modules 9 Additional SCSI I O module slots buses 2 and 3 10 2 Gb Small Form Factor Pluggable SFP Transceiver MSA1000 The MSA1000 is a 2 Gb Fibre Channel entry level to mid range SAN storage system scaleable to 12TB It is designed to reduce the complexity expense and risk of deploying hi