Home
Owner``s Manual
Contents
1. Connect the air tube and water tube to the connectors on the misting fan pole assembly by pushing the tubes all the way into the corresponding connectors fig 13 Note small diameter tube Water and large diameter tube Air oon Ww Rev 06 11 AMMF16R 1 6 Operating Instructions IMPORTANT Read this owner s manual before operating this product THE MISTING FAN IS INTENDED FOR OUTDOOR USE BUT MAY BE USED INDOOR WITHOUT THE MISTING FEATURE Place the misting fan on a level surface near an electrical outlet Place the misting fan out of reach of children Do not insert anything into the fan guards If moving the misting fan to a different location turn it OFF and unplug it from the socket e To operate the misting mist fan plug the power cord into a 120 VAC 60Hz outlet CAUTION MISTING FAN AND OR MISTING SYSTEM MAY START UP WHEN THE UNIT IS INITIALLY PLUGGED INTO THE POWER OUTLET e Fan Operation ON OFF Speed control Press the button to Low Medium High or OFF to select fan speed fig 1 e Fan Operation Oscillation Control To activate the oscillation function press down the oscillation switch To deactivate stop the oscillation function pull up the oscillation switch The oscillation angle is approximately 65 degrees fig 2 e Misting Operation IMPORTANT This product is designed to operate with city water supply Make sure your water pressure is lower than 100 PSI 40 to 80 PSI water pres
2. a water reservoir example bathtub or pool or anything containing an electrical conductive substance When the product is used outdoors use only on GFCI Ground Fault Circuit Interrupter protected receptacles This product must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a cord having an equipment grounding conductor and a grounding plug Plug into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances Avoid contact with moving parts Do not hang or mount misting fan on a wall or ceiling Do not operate without misting fan guards properly in place CAUTION DO NOT USE IN A WINDOW FAILURE TO DO SO COULD RESULT IN THE PRODUCT COMING APART DURING OPERATION AND OR PERSONAL INJURY Rev 06 11 AMMF16R 1 4 Carton Contents Pack List 1 Front fan guard assembly 2 Rear fan guard 3 Rear fan guard nut screw on motor housing 4 Fan blade 5 Fan blade nut screw on motor axis 6 7 8 9 1 2 P Power base assembly Fan head assembly Fan pole assembly Fan pole screw 0 Screws 3 nyo _ Rev 06 11 AMMF16R 1 5 General Assembly Instructions A Phillips head screwdriver is needed for assembly 1 Ensure that the power cord is disconnected from the power
3. 16 Outdoor Misting Oscillating Fan Model Number AMMF16R 1 Owner s Manual SI W oet READ AND SAVE THESE INSTRUCTIONS Intertek 3084514 CONFORMS TO UL STD No 507 Certified to CSA STD C22 2 No 113 CAUTION Before using this product read this manual and follow all safety rules and operating instructions Failure to comply with instructions could result in personal injury and or property damage IMPORTANT For replacement parts or assembly questions call 1 800 320 6478 or go to www auramist net Rev 06 11 AMMF16R 1 1 LEL ICRA E SECTION PAGE Tic Safety Informatio n ita Se tee eis E AEEA ete eee eke EAL R ata 2 22H Camon GOMlemtS catia weet ite hain eens E ae al eatin seit AE cone cette oe staat T 5 3 General Assembly Instructions iss ccjccec ca decetena pa vena eess cece caneg ie eds cacucecivends cecbeaceaenesa thactecemnes 6 4 Operation INStructiOns cci 2068 A Peon eon Sone key aden eed ewan deine dude nantes 7 5 Maintenant sis cicens cates ch dia sid tas ceeiede ed ceca ae eda cessed dees evan ea EEEE KAERRA ENEE 9 REEL K 1e eA EE EEEE A A E E E TEE A E EA 10 Te Troubleshooting rna a be a a A dete utes EEA a tet aa oaaae bees 10 P Exploded VIEW eiro nE RE E a AE a EN E 11 Qe Parne Lisboa a sie ce a aE AE E A E ace a ie E Shel So AATA 12 NOS Watranty erene aani etry oh ahead wee A E T EE da NATER 13 Safety Warnings READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS Househo
4. Any other use may cause electrical shock fire injury to people or animals WARNING DO NOT USE THE MISTING ON OFF SWITCHES AS A MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THIS PRODUCT ALWAYS DISCONNECT THE POWER CORD 8 Disconnect the power cord before moving or performing any maintenance on the misting fan 9 This misting fan shall not be used in potentially dangerous conditions such as flammable explosive or chemically loaded atmospheres 10 Do not use or store near hazardous materials 11 Completely assemble the misting fan according to these instructions before connecting to the power source 12 If the misting fan is not working correctly has missing parts has been dropped or damaged or dropped in water call an authorized service center for evaluation adjustment or repair WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK CHECK WITHA QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE OUTLET IS PROPERLY GROUNDED DO NOT MODIFY THE PLUG PROVIDED WITH THE MISTING FAN IF IT WILL NOT FIT THE OUTLET HAVE A PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN DO NOT USEA THREE PRONG TO TWO PRONG ADAPTER IMPROPER CONNECTION MAY CREATE A RISK FOR ELECTRICAL SHOCK 13 To protect against a risk of fire electric shock or injury to persons unplug or disconnect the appliance from the power supply before cleaning and user maintenance suc
5. decrease mist density or counter clockwise to increase mist density It may take a minute for misting to start It is normal for air to come out of the nozzles before water and the mist comes out To optimize the cooling effectiveness of the system you can e Operate the unit with a DRY or WET mist based on your needs e To increase the mist density turn the mist control valve counter clockwise fig 10 e To decrease the mist density turn the mist control valve clockwise fig 11 2 Operating Tips For dry climates increasing the water flow will provide maximum cooling results In humid climates a reduced water flow is recommended Maintenance CUSTOMER RESPONSIBILITIES Read and follow the maintenance schedule and the maintenance procedures listed in this section WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE MOVING OR SERVICING THE MISTING FAN WARNING DO NOT IMMERSE THE MISTING MIST FAN IN WATER REPLACING FILTERS WARNING ANY SERVICING OF THIS UNIT EXCEPT FOR GENERAL MAINTENANCE DESCRIBED IN THIS SECTION SHOULD BE PERFORMED BY AN AUTHORIZED SERVICE REPRESENTATIVE CAUTION The filters have been designed to provide optimal system performance by catching any debris that may enter the supply lines throughout use Semi annual replacement of both the air and water filters ensures the life of your system e Remove the filter cover and locate the air and water filters fig 1 e The filters are connected to
6. h as lubrication 14 To protect against electrical shock do not immerse unit plug or cord in water or spray with liquids 15 Keep the cord away from heated surfaces 16 To reduce the risk of injury from the misting fan accidentally starting unplug the power cord before replacing the filter 17 Do not leave the misting fan unattended when it is plugged in Unplug it from the power outlet when not in use and before servicing Turn off the misting fan before unplugging 18 Do not operate the misting fan with a damaged power cord plug or if the misting fan is damaged in any manner Call an authorized service center for evaluation adjustment or repair Rev 06 11 AMMF 16R 1 3 19 20 21 22 23 24 25 26 27 28 Do not run cord under carpets Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not insert or allow any foreign objects to enter the intake or exhaust air openings as it may cause mechanical electrical or fire damage to the mist fan Do not block or tamper with the misting fan nozzles as it may reduce or impede the functionality or quality of the mist Call an authorized service center for evaluation adjustment or repair Always place the misting fan on a stable flat surface to avoid the chance of tipping Never place the misting fan where it may fall into
7. l nut 1 19 ZFO1MF 10 02 fan blade 1 20 ZFO1MF 10 21 blade nut 1 21 ZFO1MF 10 01 front guard 1 22 FV9144 00 03 nozzle housing frame 3 23 ZFO1MF 00 05 front cover 1 24 TODXD9 18 UL power cable assembly 1 25 ZFO1MF 00 03 filter door 1 26 ZFO1MF A0 04 pole cover assembly 1 27 WVDQ10 05 06 pump switch 1 Rev 06 11 AMMF16R 1 Warranty ONE YEAR FULL WARRANTY This product is warranted for one year from the date of purchase against defects in materials and workmanship At our discretion parts that prove to be defective will either be repaired or replaced or the whole product will be replaced In either case copy of your proof of purchase will be required In case that any mechanical or electrical repairs are required during the warranty period send your complete product postage or freight prepaid to the auraMIST service center near you Call the number below to get the nearest service center This warranty does not include the air or water filters which are expendable parts that can wear out from normal use within the warranty period This warranty applies for only 90 days if this product is ever used for commercial or rental purposes auraMIST Inc 5210 Village Parkway Rogers AR 72758 The model number and manufacturing date code can be found on the label attached to the back of the power unit You should record both the model number and the date of purchase and keep in a safe place for futu
8. ld Type SAVE THIS MAN UAL FOR FUTURE REFERENCE READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE Read and understand this instruction manual and all labels on the misting fan before using Safety is a combination of common sense staying alert and knowing how this misting fan works Use this misting fan only as described in this manual To reduce the risk of personal injury or damage to the misting fan use only recommended accessories Understanding Safety Terminology DANGER If safety information is not followed someone will be seriously injured or killed WARNING If safety information is not followed someone could be seriously injured or killed CAUTION If safety information is not followed someone may be injured Rev 06 11 AMMF16R 1 2 When using this misting fan follow basic safety precautions including the following WARNING To reduce the risk of fire electric shock or injury Make sure that the power source complies with the electrical requirements of the misting fan Do not use this misting fan with any solid state speed control device Do not expose to rain Store indoors Do not use this misting fan with a damaged filter or without a filter installed To reduce the risk of personal injury the misting fan should not be used as a toy or placed where children can reach it OF PONS Close supervision is necessary when any appliance is used near children 7 Use this misting fan only as described in this manual
9. outlet 2 Align fan pole assembly to the power base assembly hole as illustrated Gently push the hose and power cable aside and press the mist fan pole until the screw hole is aligned to the base fig 1 CAUTION Make sure you do not kink the hose in this process Fasten the fan pole assembly to the power base assembly with the two screws fig 1 Fasten the fan pole to the power base assembly with the fan pole screw fig 2 Loosen the pole lock knob and pull the inner pole out then tighten the pole lock fig 3 Loosen the locking knob on the fan head assembly and attach the fan head assembly to the pole then tighten screw knob to secure the fan head assembly fig 4 7 Disassemble the rear fan guard nut and the misting fan blade nut from the misting fan head assembly fig 5 8 Align the rear fan guard holes to the three pins on the motor housing and fasten the rear fan guard to the fan head assembly with the rear fan guard nut figure 6 9 Mount the fan blade to the fan motor shaft fig 7 Make sure the fan blade gap aligns with the pin clip on the motor shaft and screw on the blade nut fig 8 10 Align the front and rear guard and secure all the hinges around the outer rims of the fan guard figures 9 amp 10 11 Fasten the front and rear fan guards with the supplied screw fig 11 12 Connect all three nozzle housings by gently sliding the nozzle housing into the holder on the front fan guard fig 12 13
10. re reference MODEL NUMBER XXXXX MFG DATE CODE XXXX DATE OF PURCHASE XX XX XX CUSTOMER SERVICE NUMBER 1 800 320 6478 Website www auramist net Rev 06 11 AMMF16R 1 13
11. sure will ensure optimal functionality of the system throughout maintenance intervals The misting fan and or misting system may start up when the unit is initially plugged to the power outlet DO NOT USE THE MISTING FEATURES INDOORS Rev 06 11 AMMF16R 1 7 te feet o IM PORTANT BEFORE STARTING Make sure the ball valve of the fan is placed in the OFF position fig 1 e Turn the mist control valve clockwise until the valve is closed fig 2 e Connect the water hose connector to the garden hose fig 3 e Please keep the mist fan 12 feet away from your furniture and other electrical appliances fig 4 Misting ON OFF control Mist ON 1 Press the rocker switch to the ON position fig 5 2 Turn the ball valve to the ON position fig 6 3 Open the flow control valve until mist is visible then refer to ADJUSTING MIST DENSITY section to get an optimal mist performance fig 7 Mist OFF 1 Turn the ball valve to OFF position fig 8 2 To prevent the accumulation of mineral deposits let the pump run for 2 minutes after closing the ball valve so the air pump can clear the remaining water from the nozzles 3 Turn the pump switch to the OFF position when complete fig 9 Rev 06 11 AMMF16R 1 8 ADJUSTING MIST DENSITY CAUTION Do not over tighten and or loosen the water flow control valve The misting function of this fan is adjusted by turning the flow control valve on the fan pole assembly clockwise to
12. the system via Push In connectors for ease of service Rev 06 11 AMMF 16R 1 9 e Remove the screw of the push in connector and water flow control valve fig 2 e Push the connector ring and pull out the air filter hose from the push in connector and the water filter hose from the water flow control valve fig 3 e Dispose of old filter e Remove filter from package and orient the directional arrow so that the flow direction is towards the up fig 4 e Push the hose into the push in connector to connect the filters fig 4 e Assemble the push in connector and water flow control valve e Reinstall filter cover fig 5 Storage CAUTION DO NOT USE GASOLINE THINNER ALCOHOL SOLVENTS OR OTHER HARSH CLEANNERS OR CHEMICALS TO CLEAN THE FAN THEY WILL DAMAGE THE MISTING FAN e Clean the unit with a soft cloth and mild soap solution e Dry all parts completely e Store the mist fan in a clean and dry place Troubleshooting PROBLEM CAUSE CORRECTION Misting fan not running Power cord is not connected Connect power cord 2 Switch is in the OFF position 2 Switch mist fan on high medium low and positions Unit not misting 1 Water faucet is OFF 1 Open the water faucet 2 Ball valve is OFF 2 Switch the ball valve to ON position 3 Misting valve in the CLOSED 3 Open valve counterclockwise position 4 Water filter could be clogged 4 Replace water filter Water s
13. treaming from 1 Air pump is not working 1 Turn on the mist ON OFF switch nozzle 2 Air flow is low 2 Change the intake filter of air pump 3 Air filter needs replacement 3 Replace air filter 4 Air hose leaks 4 Turn off mist fan motor and feel any air leaks on hoses 5 Foreign object in nozzle 5 Order and replace nozzle Mist is not balanced on 1 Low water flow 1 Adjust the water flow control valve three nozzle 2 Water hose leaks 2 Turn off mist fan motor and feel any air leaks on hoses Rev 06 11 AMMF16R 1 10 Exploded View 27 26 25 24 23 22 MN AY ii Ly Rev 06 11 AMMF16R 1 11 Parts List No Part No Description QTY 1 FV9144 A0 01 nozzle assembly 3 2 FV9144 A0 02 nozzle hose assembly 1 3 FV9144 A0 03 8 connector 1 4 FV9144 A0 04 6 water flow control valve 1 5 FV9144 50 00 6 water filter 1 6 FV9144 40 00 8 air filter 1 7 FV9144 60 00 clapboard connector 1 8 FV9144 A0 05 angle connector 1 9 ZFO1MF A0 01 water inlet hose assembly 1 10 FV9144 70 03 water pre filter 1 11 FV9144 70 10 ball valve 1 12 ZFO1MF A0 02 base plate assembly 1 13 ZFO1MF 30 00 pump Bushings 4 14 WZQB01 00 00 air pump 1 15 ZFO1MF 20 00 fan pole assembly 1 16 ZFO1MF A0 03 fan head assembly 1 17 ZFO1MF 10 03 rear guard 1 18 ZFO1MF 10 22 rear gril