Home
TH115-AF-120S and TH115-AF-240S - Electric Radiant Floor Heating
Contents
1. thermostat s display Hi range Heating is deactivated Er Verify the thermostat and sensor connections Technical Specifications Power supply Refer to the power base s installation guide Display range 0 C to 70 C 32 F to 158 F Ambient setpoint range A AF modes 5 C to 30 C 40 F 86 F Floor setpoint range F mode 5 C to 40 C 40 F 104 F Floor limit range AF mode 5 C to 40 C 40 F 104 F Display resolution 0 5 C 1 F Operating temperature 0 C to 50 C 32 F to 120 F Storage temperature 20 C to 50 C 4 F to 120 F Heating cycle length Refer to the power base s installation guide Data backup In the event of a power failure most settings are saved Only the time must be re adjusted if the power failure lasts more than 6 hours The thermostat will return to the mode that was active prior to the power failure V Warranty Aube warrants this product excluding battery to be free from defects in the work manship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii contact Aube Aube w
2. at the top of the control module in the slots at the top of the power base Control module Air vents Secure the control module using the captive screw underneath the base Air vents Power base NOTE Keep the thermostat s air vents clean and unobstructed at all times TH115 A F AF TH115 A F AF User Guide Programmable Thermostat Clock and Day Setting Press the Hour button to set the hour Set the Min button to set the minutes Set the Day button to set the day Press ModelRet to exit Daylight Savings Time The thermostat can automatically re adjust its clock at Daylight Sav ings Time changeover When this function is enabled On the ther mostat switches to Daylight Savings Time on the second Sunday of March and to normal time on the first Sunday of November NOTE The function is disabled default setting when the clock loses its setting Press the Day button 3 seconds until DLS appears dtS on the screen n Press the av to toggle between On enabled and Off disabled Press the Day button briefly The year setting is dis played G6 Press the av to set the current year Press the Day button briefly The month setting is dis Pm gn played 12 Press the av to set the current month Press the Day button briefly The date setting is dis played Press the av to set the current date a OO 00 0O Press Mode Ret to exit Backlight T
3. d 4 Press Pgm to select another period or press Day to select another day Then repeat step 3 Press Mode Ret to exit the programming mode NOTE If no button is pressed for 60 seconds the thermostat will automatically exit the programming mode 7 2 s Manual Mode The programmed schedule is not used The temperature must be set manually To place the thermostat in this mode Press Mode Ret until 4 is displayed Set the temperature using the av or button TH115 A F AF 7 3 co Vacation Mode In this mode the thermostat is set to Vacation temperature There are two ways to place the thermostat in Vacation mode gt By pressing the button on the thermostat When the Vacation mode is activated using the button the icon appears on the screen without flashing gt From an Aube telephone controller CT240 CT241 or any other remote control device equipped with a dry contact if your power base is equipped with the ECONO input When the contact closes the Vacation mode is activated and the icon flashes on the screen All buttons on the thermostat are locked When the contact opens the thermostat returns to the preceding mode NOTE When the Vacation mode is activated using a remote control device it can only be deactivated using the device Error Messages ae The measured temperature is below the thermostat s display tU range Heating is activated The measured temperature is above the
4. d technologies Description Aube s TH115 programmable thermostats have three temperature control modes A mode gt controls the ambient air temperature F mode gt controls the floor temperature using an external temperature sensor AF mode gt controls the ambient air temperature gt maintains the floor temperature within desired limits using an external temperature sensor On Standby switch 1 paT Time and day display and GFCI reset 2 r Appears when the setpoint is displayed Temperature display o Waa M S UU Day and time Mode display MO settings i e int Preset temperature oy lt a indicator Percentage of IN ne OEE oS PESA 4 heating time 3 TOLL yyy GF OLO Ground fault indicator Olll7Fe Od Temperature control Program button _ _ h Ww p O Oa mode indicator ar C Program O Temperature clear button LO SS preset buttons Mode selection d__ Period display program exit Temperature Backlight button adjustment buttons 1 Place the switch in Standby to cut power to the heater when not in use e g in the sum mer This will not affect the time and temperature settings 2 if your thermostat is installed on a power base equipped with a ground fault protection to reset the ground fault protection switch the thermostat to Standby and bac
5. he display illuminates for 12 seconds when the backlight button is pressed When either of the av buttons is pressed the display also illuminates for 12 seconds The setpoint temperature appears for 5 seconds then the actual measured temperature is displayed Temperature Adjustment 6 1 Setpoint Temperature The thermostat normally displays the actual measured temperature To view the setpoint press one of the av buttons once The setpoint will appear for the next 5 seconds To change the setpoint press one of the av buttons until the desired temperature is displayed To scroll faster press and hold the button 6 2 Preset Temperatures The thermostat has 3 preset temperatures gt Comfort temperature x gt Economy temperature 4 gt Vacation temperature To use a preset temperature press the corresponding button The corresponding icon x or will be displayed The following table shows the intended use and the default setting of each of the preset temperatures Icon Intended use A AF modes F mode XE a home 21 C 70 F 28 C 82 F q So or away from home 17 C 63 F 20 C 68 F E HANTAR absence 10 C 50 F 10 C 50 F To store a preset temperature Set the desired temperature using the av buttons Press and hold the corresponding button until the corresponding icon is displayed 400 115 003 B 27 2 07 1 2 6 3 Floor Tem
6. ill make the determination whether the product should be returned or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by dam age which occurred while the product was in the possession of a consumer Aube s sole responsibility shall be to repair or replace the product within the terms stated above AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PROD UCT Some provinces states or regions do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some provinces states or regions do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from province state or region to another 75 Customer Assistance For any questions regarding product installation or operati
7. ituation For example you can skip periods 2 and 3 for the weekend Period Description Associated temperature setting fit Wake up es Ni Away from home C en Return home X T Sleep q The Comfort X temperature is used in periods 1 and 3 and the Economy 4 temperature is used in periods 2 and 4 For example when the period changes from 1 to 2 the setpoint automatically changes from Comfort x temperature to Economy 4 temperature You can have a different program for each day of the week i e each period can start at different time for each day of the week The thermostat has been programmed with the following schedule Period Setting MO TU WE TH FR SA SU a ses 6 00 6 00 6 00 6 00 6 00 6 00 6 00 ore q 8 30 8 30 8 30 8 30 8 30 oo oo Nek kos 17 00 17 00 17 00 17 00 17 00 1 HA q 23 00 23 00 23 00 23 00 23 00 23 00 23 00 To modify the schedule Press Pgm to access the programming mode Period 1 is selected Press Day to select the day to program hold for 3 seconds to select the entire week Press Hour and Min to set the start time of the selected period or press Clear if you want to skip the period is displayed NOTE If you intend to use only 2 periods set periods 1 and 4 or periods 2 and 3 Early Start will not work if you set periods 1 and 2 or periods 3 an
8. k to On 3 The thermostat displays the percentage of heating time required to maintain the desired temperature For example is displayed when heating is activated 40 percent of the time Display f MY 15 ISA of heating time 1 to 24 25 to 49 50 to 74 75 to99 100 4 GFI appears when the ground fault protection has tripped Configuration Some thermostat configurations can be modified via switches on the back of the faceplate control module oon Default factory settings are inside the gray cells l2 3 Configurations UP DN 1 Display format F 12h C 24h 2 Early Start Enable Disable 3 Temperature control mode F AF a Early Start can be used in Automatic mode only When this function is enabled the thermostat calculates the optimal time to start heating in order to obtain the desired temperature by the set time The thermostat re assesses the start time daily based on the previous day s results b To select the F mode place the switch in the F position To select the AF mode place the switch in the AF position and ensure that the remote temperature sensor is connected to the thermostat To select the A mode place the switch in the AF position and ensure that the remote temperature sensor is NOT connected to the thermostat Installation Refer to the installation instructions of the power base insert the tabs
9. ly and load using sold erless connectors for copper wires figure 1 For floor heating applications insert the floor sensor wires through one of the two holes below the terminals figure 2 and connect the wires to terminals 3 and 4 no polarity NOTE The wires must run alongside the terminals and not go over them The wire must not cross any heating wires nor be placed directly on a heating wire or adjacent to it For best performance the sensor probe should be centered between the wires in the mat WARNING This power base does not have a built in ground protection device Therefore for floor heating applications you must install a sepa rate ground protection device at the main electrical panel Contact your Aube authorized representative if you need a thermostat with built in ground protection device if you wish to use a remote controller such as the CT240 or CT241 insert the cable use 18 to 22 gauge flexible wires into one of the two holes available below the terminal board and connect to terminals 1 and 2 of the base figure 2 Push the excess length of the high voltage wires back into the electrical box secure the power base to the electrical box using the provided screws PB112 PB112 Installation Instructions For models 120S 240S 240D i necessary set the configuration switches on the control module refer to the control module user guide install the control module on
10. on contact us at 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada Tel 450 358 4600 Toll free 1 800 831 AUBE Fax 450 358 4650 E mail aube service honeywell com ot For more information on our products visit us at www aubetech com 400 115 003 B 27 2 07 2 2 is technologies Parts Oo One 1 power base Two 2 screws Four 4 solderless connectors for copper wires NOTE Special CO ALR solderless connectors must be used for connecting aluminum conductors Option one 1 AC112 01 floor sensor ordered separately required for floor heating applications only Guidelines Turn off power to the heating system at the main electrical panel to avoid electrical shock The installation should be carried out by an elec trician NOTE This power base must be used with thermostat operating on 15 minute cycles gt High voltage thermostats must be installed onto an electrical box The following guidelines are not necessary for floor heating applica tions gt For a new installation choose a location about 1 5 m 5 ft above the floor and on an inside wall gt The thermostat must be installed on an inside wall facing the heating system Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimneys or stove pipes Procedure Connect the power base wires to the power supp
11. perature Limits AF mode only NOTE To avoid damaging your floor follow your floor supplier s recom mendations regarding floor temperature limits The minimum and maximum floor temperature limits are 5 C 41 F and 28 C 82 F by default To modify these limits proceed as follows Switch the thermostat to Standby Press and hold the lt button Switch the thermostat back to On Release the x button when the minimum temperature limit Fl L appears Set the minimum temperature limit using the av buttons Press the xt button to display the maximum temperature limit FL H Set the maximum temperature limit using the av buttons OO 80 60086 Press Mode Ret to exit Modes of Operation The thermostat has 3 modes of operation 7 1 Automatic Mode The thermostat follows the programmed schedule To place the ther mostat in this mode press Mode Ret until is displayed The data of the current schedule period are also displayed Temporary Bypass If you modify the setpoint temperature by pressing the av lt or 4 button when the thermostat is in automatic mode the new tempera ture will be used until the beginning of the next period flashes dur ing the bypass You can cancel the bypass by pressing Mode Ret Programmed Schedule The schedule consists of 4 periods per day which represents a typi cal week day You can program the thermostat to skip the periods that do not apply to your s
12. to the base Apply power to heating system Power Figure 1 U Load Figure 2 a ECONO Flo INPUT SENSOR Technical Specifications Model Supply Max Load Power Wiring 120S 120 VAC 50 60Hz 16 7A 2000 W 4 wires single pole 240 VAC 50 60Hz 4000 W i 240S 208 VAC 50 60Hz 16 7 A 3475 W 4 wires single pole 240 VAC 50 60Hz 3600 W 240D 208 VAC 50 60Hz 15A 3120 W 4 wires double pole Storage 4 F to 120 F 20 C to 50 C Remote controller input ECONO requires a dry contact Size H W e D 4 89 x 2 76 x 0 91 in 124 x 70 x 23 mm Certifications Cc US LISTED 400 112 006 C 26 2 07 11
Download Pdf Manuals