ATN PS-22
Contents
1. 22 with two screws M4x7 B from the kit 2 Mount the PS 22 with A R M S Adapter onto the A R M S 10 or A R M S 19 ACOG C with two screws M5x8 D 3 Unscrew the protective back cap from PS 22 4 Screw the Rubber Light Suppressor E into the thread at the PS 22 back side 5 Loosen slightly the fixing screws or levers F of the mount 6 Place the PS 22 onto the weaver rail of the fire arm before objective of daytime scope atthe minimal distance from it The optical axis of PS 22 must have divergence with the optical axis of daytime scope not more than 3mm The height of PS 22 optical axis over the with A R M S 19 ACOG is equal to 49mm 7 Tighten the fixing screws or levers F of mount NOTE Fixing screws may need to be tightened again after continuous shooting Mounting onto the objective of the day scope with Scope Mounting System 1 Unscrew the protective back cap from PS 22 2 Screw the Scope Mounting System body A into the thread at the PS 22 back side 3 Slightly loosen the fixing screw B of the Scope Mounting System 4 Put the Insert C with the required diameter into the System s body 5 Slide the PS 22 with the Scope Mounting Sys tem to the objective of a day scope 6 Tighten hard the fixing screw B of the Scope Mounting System Mounting Picatinny Rail and IR450 1 Mount Picatinny Rail A onto the body of PS 22 with two screws M4x7 B from the kit 2 Place IR Illuminator
2. C onto the Picatinny Rail p i A TABLE 1 SCOPE MOUNTING SYSTEM PARAMETERS AND SCOPE EXAMPLES Diameter of the Scope Objective Scope Mounting System Insert Size Examples of Scopes Leupold 1 5 5x20 PR Leupold 1 5 5x20 MR T M2 Zeiss 1 1 4x24 T Meopta Artemis 2000 4x32 AB imin Leupold Mark 4 3 9x36 Leupold Mark 4 2 5 8x36 Kahles 4x36 7 Leupold 3 5 10x40 Leupold VX II 3 9x40 Zeiss 1 5 6x42 Swarovski PV N 2 5 10x42 3 from 48 7 to 49 0 mm Meopta Artemis 3000 3 9x42 Meopta Artemis 3000 4 12x40 Schmidt Bender 10x42 PMII Zeiss 2 5 10x50 4 Schmidt Bender 3 12x50 Leupold 4 4 14x50 Leupold VX III 3 5 10x50 62 Zeiss 3 12x56 Swarovski 2 5 10x56 Kahles CSX 3 12x56 CAUTION Never use an Insert with the Scope Mounting System that do not correspond each other are in different rows at the Table 1 How to select Scope Mounting System required for your daytime scope Owing to Scope Mounting Systems with Inserts having different diameters you can mount PS 22 At tachment onto a daytime scope with objective tube diameter from 25 to 62 mm the way the tube glowing will be absolutely invisible for others At the Table 1 Scope Mounting System sizes 1 6 and Insert sizes for different scope examples are provided You may not find your daytime scope and Scope Mounting Systems with Insert needed at the Scope Examples column In this case before mounting procedure you have to select Scope Mounting System and Insert requ
3. the side of the body of device Place the Remote Control on the weapon suiting your shooting style best and grip Fix the Remote Control in this position with a montage strap For using the device with Remote control rotate the Operation Switch from the OFF position to STB posi tion To turn the device on push the button of remote control Keep pressed button when observing scene The scope is turned off immediately after releasing remote control button To switch the Remote Control mode OFF rotate the Operation Switch from the STB position IR ILLUMINATOR The IR illuminator greatly enhances the performance of your PS22 while remaining almost totally invis ible to the naked eye NOTE It is important to remember that the IR illuminator is simply an infra red light source and like any light source it may loose its effectiveness over a great distance IR450 illuminator is mounted onto the picatinny rail The IR illuminator control buttons are located on its side To switch the Digital IR illuminator a on off press and buttons simultaneously When the IR illuminator is switched on you can see the green LED lit By pushing the buttons and you may adjust the IR brightness The IR beam is focusable to change the field of coverage To change the beam width slightly turn the IR lens You could change the IR control panel fitting your needs The wrench included into the set should be used for weakening t
4. 50 hours Gen 3 Operating Temperature ccccccceeecccecseeeeeeeceeeeceeeaeeeeeeeseeeeeeeseeeeeeeeseaaeeeeesseeeeeeeseeseeeeeeas 40 C to 50 C Storage Temperature escrime iriri E i SIEEN 50 C to 70 C MONSON aea a E E E EEE 139mm X 80mm X 72mm MN UW EEE E EE E pops E ER T AE EE A E A T E A E A E E E 0 6kg ATN reserves the right to change the above specifications at any time without notice CAUTION THIS PRODUCT CONTAINS NATURAL RUBBER LATEX WHICH MAY CAUSE ALLERGIC REACTIONS MOUNTING Mounting onto the Weaver rail with 7 8 Weaver Mount 1 Mount the 7 8 Weaver Mount A onto the body of PS 22 with two screws M4x7 B from the kit 2 Unscrew the protective back cap from PS 22 3 Screw the Rubber Light Suppressor C into the thread at the PS 22 back side 4 Loosen slightly the fixing screws D of the mount 5 Place the PS 22 onto the weaver rail E of the fire arm before objective of daytime scope at the minimal distance from it The optical axis of PS 22 must have divergence with the optical axis of daytime scope not more than 3mm The height of PS 22 optical axis over the weaver rail is equal to 40mm with a standard mount that also matches ATN 3 5x26 scope 6 Tighten the fixing screws D NOTE Fixing screws may need to be tightened again after continuous shooting Mounting onto the Weaver rail with A R M S Mount 1 Mount the A R M S Adapter optional A onto the body of PS
5. ATN PS 22 NIGHT VISION ATTACHMENT user s guide Important Export Restrictions Commodities products technologies and services contained in this manual are subject to one or more of the export control laws and regulations of the U S Government and they fall under the control jurisdiction of either the US Department of State or the US BIS Department of Commerce It is unlawful and strictly prohibited to o A a to aa eae oo AMERICAN or sell any hardware or technical data or furnish any service to any foreign person whether abroad or TECHNOLOGIES in the United States for which a license or written NETWORK approval of the U S Government is required without CORP first obtaining the required license or written approval from the Department of the U S Government having jurisdiction Diversion contrary to U S law is prohibited FAST CATADIOPTIC REMOTE FOCUSING RING FRONT LENS CONTROL SYSTEM WITH CAP MULTI COATED ALL GLASS OPTICS BATTERY CAP OPERATION SWITCH FRONT LENS CAP RUBBER LIGHT 7 8 WEAVERMOUNT BACKCAP_ PICATINNY RAIL IRILLUMINATOR DAYLIGHT FILTER SUPPRESSOR IR450 REMOTE CONTROL A R M S ADAPTER DAY SCOPE LIGHT PLATFORM RING SCOPE MOUNTING OPTIONAL SUPPRESSOR OPTIONAL OPTIONAL SYSTEM OPTIONAL ATN PS 22 with ATN 5x33L and IR 450 ATN PS 22 with ATN 3 5x26 and IR 450 with 7 8 weaver mount and platform with Scope Mounting System ring for IR450 ATN PS 22 with ATN 5x33L a
6. as 5 AT 146534 758 Scope Mounting System Insert with 49 5 mm diameter AT 146534 759 Scope Mounting System Insert with 50 mm diameter or o1f O71 AT 146534 760 Scope Mounting System Insert with 56 mm diameter AT 146534 761 Scope Mounting System Insert with 57 mm diameter UITI AT 146534 762 Scope Mounting System Insert with 58 7 mm diameter AT 146534 763 Scope Mounting System Insert with 62 mm diameter Oa 5 o1 Figure A1 Figure A2 5 Figure A3 For customer service and technical support please contact American Technologies Network Corp North American Office 1341 San Mateo Avenue South San Francisco CA 94080 phone 800 910 2862 650 989 5100 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2009 ATN Corporation
7. he fixing nut located on the IR Rotate the IR placing at in the most convenient position Tighten the nut with the wrench to fix the new position Q Battery Housing IR Brightness Adjustment IR Elevation IR Focusing Nut Fixation Screw IR Windage WARNINGS AND CAUTIONS e Do not forget to turn off the PS 22 when it is not in use If you do not plan to use your unit for a period of more than 10 days you should remove the batteries e Keep lens cap on when PS 22 is not in use e Avoid contact with dust steam and gas e The PS 22 is not harmful for its user or environment e Do not disassemble it will void your warranty e Never use in daylight conditions without the lens cap on e Never point the PS 22 at a bright light source If the device shuts off automatically after directing it at a bright light source turn the unit off and wait for 1 2 minutes before turning the unit back on e Adverse atmospheric conditions such as fog smog or haze and a lack of ambient light moon or starlight may decrease the effective viewing distance All technical data for this unit was compiled in a controlled environment e If you use the rubber eyecaps for a long period of time you may suffer skin inflammation If you de velop any symptoms consult a doctor immediately TROUBLESHOOTING Q Flashes flickers or clicking occur while operating S If it occurs within the first five minutes of inserting new batteries it is no
8. ired for your daytime scope To do this perform the following actions 1 Determine your daytime scope objective tube diameter ex ternal not diameter of the glass lens with a millimeter ruler with a trammel for more accurate results as shown at the pic ture 2 Select from the Table 1 the Insert size closest larger to the value measured Insert size is also specified at an Insert body Do the selection in Insert group that corresponds to the same Scope Mounting System for example Scope Mounting System 2 3 The Scope Mounting System you need is the one that corre sponds to Insert size selected atthe Table 1 For example if your scope objective tube diameter is equal to 46 mm then you should select Insert with size of 46 7 mm and cor responding Scope Mounting Systems 3 from the Table 1 Platform Ring IR Illuminator can be mounted not only onto PS 22 with Picatinny Rail Adapter but also onto a daytime scope using optional Platform Ring To perform this do the following 1 Unscrew the two screws set A from the Plat form Ring 2 Place the top and lower parts of the Platform Ring around your daytime scope tube B as shown on the picture 3 Tighten hard the two screws set A Daytime Scope Light Suppressor There is a rubber Daytime Scope Light Suppressor DSLS The DSLS slides over the eyepiece of your daytime scope The DSLS was designed to achieve several missions 1 Prevent back glow fr
9. is warranty is extended only to the original purchaser Any breach of this warranty shall be waived unless the customer notifies ATN at the address noted below within the applicable warranty period The customer understands and agrees that except for the foregoing warranty no other warranties written or oral statutory expressed or implied including any implied warranty of merchantability or fitness for a particular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings costs expenses damages or liabili ties arising out of the use of this product Operation and use of the product are the sole responsibility of the Customer ATN s sole undertaking is limited to providing the products and services outlined herein in accordance with the terms and conditions of this Agreement The provision of products sold and services performed by ATN to the Customer shall not be interpreted construed or regarded either expressly or implied as being for the benefit of or creating any obligation toward any third party of legal entity outside ATN and the Customer ATN s obligations under this Agreement extend solely to the Cus tomer ATN s liability hereunder for damages regardless of the form or action shall not exceed the fees or other charges paid to ATN by the customer or customer s dealer ATN shall not in any eve
10. me Return Address reason for service return Contact information such as valid telephone numbers and or e mail address and proof of purchases that will help us to establish the valid start date of the warranty Product merchandise returns that do not have an RMA listed may be refused ora significant delay in processing may occur Estimated Warranty service time is 10 20 business days End user customer is responsible for postage to ATN for warranty service ATN will cover return post age shipping after warranty repair to end user customer only if product is covered by aforementioned warranty ATN will return product after warranty service by domestic UPS ground and or domestic mail Any other requested or required shipping method the postage shipping fee will be the responsibility of the end user customer 8 APPENDIX A SPARE PARTS LIST The Spare Parts List is an illustrated catalog of main parts and assemblies completing the Night Vision Attachment PS 22 here in after referred to as PS 22 Therefore in case of failure of any part or assembly User could replace it by ordering the corresponding part assembly from the Spare Parts List The amount and assortment of the spare parts needed should be arranged with each contract individually TABLE A1 ATN PS 22 SPARE PARTS LIST PART NO DESCRIPTION FIG TABLE A1 ATN PS 22 SPARE PARTS LIST CONT PART NO DESCRIPTION FIG ITEM TAT 146534755 Scope Mounting System insert wih 4e7mmdameta
11. nd IR 450 ATN PS 22 with Leupold daytime scope with Scope Mounting System and picatinny with the 7 8 weaver mount rail for IR illuminator ATN PS 22 with Te daytime scope ATN PS 22 with a spotting scope with 7 8 weaver mount The information in this manual furnished for information use only is subject to change without notice is not to be construed as acommitment by ATN Corp ATN Corp assumes no responsibility or liability for any errors or inaccuracies that may appear in this book 2009 ATN Corp All right reserved APPLICATION The PS 22 is an attachment for daytime scopes with 1x 6x 2 5x 4x are optimal magnification that converts the scope into a high quality compact night vision scope The PS 22 mounts in front of a daytime scope Re zeroing of a scope is not required PS 22 comes witha standard 7 8 weaver mount There is also A R M S Adapter optional for A R M S quick release mount Optional Scope Mounting System allow to mount the unit onto the objective of a day scope with 25 58mm diameter The powerfull IR450 illuminator can be mounted onto the Picatinny Rail The PS 22 utilizes a 2nd Gen or 3rd Gen Image Intensifier Tube This ingenious scheme allows the shooter to go from day to night in less then 30 seconds without tools without changes in eye relief remain ing zeroed all around the clock The PS 22 is a complex optical electronic system The device contains an image intensifier tube assembly with an i
12. nt be liable for special indirect incidental or consequential damages including but not limited to lost income lost revenue or lost profit whether such damages were foreseeable or not at the time of purchase and whether or not such damages arise out of a breach of war ranty a breach of agreement negligence strict liability or any other theory of liability PRODUCT WARRANTY REGISTRATION In order to validate the warranty on your product ATN must receive a completed Product Warranty Registration Card for each unit or complete warranty registration on our website at www atncorp com Please complete the included form and immediately mail it to our Service Center ATN Corporation 1341 San Mateo Avenue South San Francisco CA 94080 OBTAINING WARRANTY SERVICE To obtain warranty service on your unit End user must notify ATN service department by calling 800 910 2862 or 650 989 5100 or via e mail service atncorp com to receive a Return Merchan dise Authorization number RMA When returning please take or send the product postage paid with a copy of your sales receipt to our service center ATN Corporation at the address noted above All merchandise must be fully insured with the correct postage ATN will not be responsible for improper postage or missing or damaged merchandise during shipment When sending product back please clearly mark the RMA on the outside of the shipping box Please include a letter that indicates your RMA Na
13. ntegrated high voltage power source and a three volt battery housing Objective lens protective cover is intended to protect objective lens from dust scratches and high level illumination The pinhole in cover allows the user to check the operation ability of the device in highlight conditions The device has a built in Automatic Brightness Control This system automatically adjusts the brightness of Image Intensifier Tube to the optimal level FEATURES e Easily changes daytime scope to Night Vision e Mounts in front of daytime scope no re zeroing required e Available in 2nd and 3rd generation e Multi coated all glass optics e Fast catadioptic front lens system e 21mm output window e Light weight and rugged e Tactical Digital Remote Control e Comes with a standard 7 8 weaver mount e Optional A R M S Adapter for A R M S quick release mount included e Optional Scope Mounting System for mounting onto the objective of the day scope 25 62 mm diameter SPECIFICATIONS Magnea OU secsi cere ae cies exter neater E a 1X Hahv are tite Gil 2 SeReene eee neha tek ener eee lanae Sete Rear REn AEE teeter tt Stee Sete near teers Nces Mere nn nme Seen inane 2nd Gen or 3rd Gen DS y E eaa e a kone E NE EE E E A E E F1 1 44 80mm TD ess cata retest E A E E T cst nanatindavenesimadenen ts 13 POW el SUNY E AEE O A OA AAAA A A AE E T one 3 Volt Battery CR123A Range Oi FOCUS cr a a 10 m to Infinity BAUEN EIE os E E 60 hours Gen 2
14. om the device that could give away position 2 Prevent surrounding light from interfering with image on eyepiece The DSLS can be adjusted for the eye relief of your scope by cutting the rubber at the desired distance OPERATION Place the PS 22 before objective of daytime scope Make sure the power switch is at the OFF position Install the battery into the housing with the polarity order shown at the de vices body The battery is 3 volt lithium battery CR123A To turn the device on draw and rotate the operation switch to the ON po sition The greenish lit screen of the image tube when looking through the eyepiece means that the image tube is powered on Do not turn the unit on during daytime without the protective lens cap day light filter on NOTE The protective lens cap has several small holes in it to allow it to be used as a daylight filter When using this as a daylight filter you will notice a double vision this is normal due to the catadioptic lens system Next move to a dark environment and remove the lens cap Observe the scene and adjust the focusing of PS 22 by rotation the focusing ring Also focus the day time scope for optimal clarity Turn on the illumination of daytime scope reticle if any and adjust its brightness see your daytime scope s user manual To turn the PS22 off draw and turn the operation switch to the OFF position REMOTE CONTROL Attach the Remote Control cable to connector on
15. rmal and the device will resume normal operation soon thereafter If it occurs for more than 10 minutes contact for service instructions Dark spots on screen These are either cosmetic blemishes in the intensifier tube or dust particles Screen becomes darker than at previous use Replace batteries If problem persists contact your dealer or other authorized service representa tive for service instructions Image not clear Adjust objective lens and or the eyepiece TUBE MAINTENANCE REPLACEMENT Tube maintenance replacement is to be performed by qualified technicians only These proce dures attempted by non qualified personnel will void warranty 1 Loosen slightly do not remove completely three set screws 1 at the Objective Locking Ring side 2 2 Unscrew the Objective Locking Ring 2 and the Objective Focusing Ring 3 3 Unscrew the Objective Directive Screw 4 5 Disassemble the Objective 5 from the Body 6 6 Unscrew the IIT Locking Ring 7 from the Body 7 Replace IIT 8 with another one During this step pay attention to Locking finger 9 that must con sist with the groove in IIT body 8 Do the steps 1 7 mentioned above in reverse order to assemble the PS 22 DOH NHND 2 YEAR PRODUCT WARRANTY This product is guaranteed to be free from manufacturing defects in material and workmanship under normal use for a period of 2 two years from the date of purchase In
16. the event a defect that is covered by the foregoing warranty occurs during the applicable period stated above ATN at its option will either repair or replace the product and such action on the part of ATN shall be the full extent of ATN s liability and the Customer s sole and exclusive remedy This warranty does not cover a product a used in other than its normal and customary manner b subjected to misuse c subjected to altera tions modifications or repairs by the Customer of by any party other than ATN without prior written consent of ATN d special order or close out merchandise or merchandise sold as is by either ATN or the ATN dealer or e merchandise that has been discontinued by the manufacturer and either parts or replacement units are not available due to reasons beyond the control of ATN ATN shall not be responsible for any defects or damage that in ATN s opinion is a result from the mishandling abuse misuse improper storage or improper operation including use in conjunction with equipment which is electrically or mechanically incompatible with or of inferior quality to the product as well as failure to maintain the environmental conditions specified by the manufacturer CUSTOMER IS HEREBY NOTIFIED THAT OPERATION OF THE EQUIPMENT DURING DAYLIGHT HOURS OR UNDER ANY EXCESSIVE LIGHT CONDITIONS MAY PERMANENTLY DAMAGE THE INTERNAL COMPO NENTS OF THE UNIT AND SAID DAMAGE WILL NOT BE COVERED UNDER THIS WARRANTY Th