Home

Amcor 12000 Air Conditioner

image

Contents

1. not designed or 4 repaired or altered in any way that adversely affected its performance or reli ability To obtain warranty service the defective product or part must be shipped or delivered to Amcor s authorized service center All postage insurance and shipping charges are the responsibility of the Purchaser and are not included in this warranty AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH ITS PRODUCTS THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF NO RESPONSIBILITY IS ASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THAT MAY RESULT FROM THE USE OF AN AMCOR PRODUCT NOR FOR THE DAMAGES DUE TO ACCIDENT ABUSE LACK OF RESPONSIBLE CARE THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT LOSS OF PARTS OR USE AT A VOLTAGE OTHER THAN SPECIFIED Some states do not allow the exclusion of limitation of incidental or consequential damages so these limitations may not apply to you Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained from or by service at any service center other than Amcor s authorized service center This warranty gives you specific legal rights and you may also have other rights which vary from state to state Product AMCOR Plasma 12000 Portable Air Conditioner Model PCMB 12000E EH Date Purchased Production Code QUESTIONS Call 1 866 361 2233 www amcorgroupusa com Dear C
2. N AMCOR Owner s Manual Plasmar oa mEn Portable Air Conditioner Model PCMB 12000E 12000 Innovative AutoDrain NanoMist Technology Patent Pending www amcorgroupusa com Table of Contents THANK TOW mn meena 2 Energy Saving WDE aiaa 2 3 BEFORE A 4 5 AUTODRAIN NANOMIST TECHNOLOGY ASSEMBLY 6 INSTALLATION OFTHE WINDOW KIT tence 7 Window Kit Installation 7 INSTALLATMONE austria aa 8 OPERATION A E 9 ia nn e e E 9 COCK O 9 Setting the emperature io ciao leed 9 isla do y 9 FaN SPECE E 9 Heat ModE 9 TO Set the a ai 9 Canceling the Timer Sleep PAGS REMOTE CONTROL 12 EMPTYING THE INTERNAL WATER CONTAINER ccce 13 14 EA 14 Cleaning Te rier isa ds 14 End 14 TROUBLESHOOTING seccion 5 NEET 18 Thank You Thank you for purchasing an AMCOR Portable Air Conditioner AMCOR is a leading brand in indoor ai
3. Subject to modifications without prior notice Please refer to the rating label for greater precision IMPORTANT e Leave the unit in an upright position for at least 2 hours before use e Always place the unit on an even surface e The power cord has a built in L C D Leakage Current Detection and Interruption circuit breaker for added safety If the power supply is interrupted please press the reset button to reconnect the unit to the power source The green light should be on e Make sure the unit is connected to a correctly grounded power supply e For proper operation the unit must be vented to the outside e Do not cover or obstruct the appliance inlet or outlet grilles e To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other steamy or wet areas e Always transport the unit in an upright position e Do not sit or stand on the unit e Do not place objects on the unit e Do not touch the unit with wet damp hands or when standing barefoot e Drainage of the water container is required before moving the unit or putting it into storage If the electric socket is different from the plug provided have a professionally qualified electrician replace the outlet with a suitable one Avoid the use of adaptor plugs multiple sockets and or extension cords if their use is necessary ensure that they conform to the current safety regulations e Do not pull the powe
4. minutes using the UP and DOWN buttons NAMCOR Press timer OFF to finish 6 To Set SLEEP MODE e Make certain unit is operating in Cool Mode Set the desired starting temperature e Press SLEEP MODE button 7 To set Auto Grill Mode e Press the SWING button for moving louvers e Press the SWING button again to stop louvers from moving 12 Note There are two instances where draining the internal water container be recommended I In the unlikely event that the Container Full Light on the LCD display flashes When the internal water container is full the back light on the LCD display flashes The unit will shut off automatically and must be drained before it will restart Emptying the Internal Water Container 2 Prior to storage of unit To Drain the Unit Switch off the unit and remove the plug from the wall socket DO NOT MOVE THE UNIT Doing this can result in water leakage damaging your floor or carpet Place the drain pan on the floor under the drain cap Remove the drain cap and the rubber stopper from the drain and let the water run out Partially fill the drain pan replace the rubber stopper and empty the drain pan This procedure must be repeated until the unit is empty Replace the rubber stopper and drain cap Put plug into the wall socket and switch the unit on The warning signal should be off Maintenance Always unplug the unit from the wall before perf
5. 2 F E Fan Speed To select the desired fan speed press the fan button Options are Slow Medium and Turbo F Heat Mode e models feature an electric heater e With the Mode Switch select the Heat Function e The fan speed is selected automatically e The heat function will operate with or without the hose attached Timer The TIMER function allows you to program the time the unit turns on and turns off TO SET THE TIMER e Press the TIME button briefly the 2 hour digits will flash e Press the UP or DOWN button to adjust the hour e Press the TIME button again The 2 minute digits will flash e Press the UP or DOWN button briefly to adjust the minutes e The TIME is set After 10 seconds the time display returns Programming the Timer for ON 24 00 00 00 e Perform the standard steps as described above The circular time scale will be on between the ON programmed times until 24 00 The flashing bar on the time scale indicates the 18 00 06 00 real time and moves a segment ahead every 30 minutes until it reaches the ON timer OFF ON time then the black segments in the circular time scale will disappear Timer Example Programming the Timer for OFF e Perform the standard steps as described above The circular time scale will be on between the present time to the OFF programmed time The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes until it reaches the
6. OFF timer time then the black segments in the circular time scale will disappear The unit will operate daily according to the timer setting unless changed After a power failure or after the unit has been unplugged you will have to program the timer settings again Canceling the Timer Setting In order to cancel the timer programming press the TIME button Sleep Mode The SLEEP MODE gradually adjusts the temperature of the unit 4 degrees upward over a 3 hour period to meet the needs of a body at rest To activate the SLEEP MODE e Ensure the unit is operating in Cool Mode Set the desired starting temperature e Press SLEEP MODE button In sleep mode fan will operate in low speed e To cancel this function press SLEEP MODE button again Shutting Off the Blue Light on Control Panel Normally there is a blue light on the LCD display To shut it off press the UP and DOWN push buttons at the same time The blue backlight will blink twice and after 3 seconds will go off Pressing any of the push buttons will re light the blue backlight Auto Grill Function 1 When unit is being connected plugged to the electricity the louvers open and close and stay closed 2 When the ON button is pressed the louvers open to the maximum and return to an angle of 75 above the upper plane of the louvers housing AUTO GRILL 3 When the swing push button is pressed the louvers swing up amp down between 30 an
7. could cause the unit to malfunction IMPORTANT The air conditioner should be left an upright position for at least two hours Reset Button A Turning the Unit On l Plug the unit into a working electrical outlet 2 Make sure the green light on the plug is on El Test Button If not press the Reset button 3 Press the unit s ON OFF Button on the LCD display It may take a few minutes before cold air is dispersed 4 Adjust FAN Speed by pressing the FAN Button until the preferred fan speed is reached Green Light 5 Press the TIME Button to Set Setting the TIME Press the TIME button for 3 seconds to set the clock The hour digits will flash Press UP or DOWN to adjust the hour Press the TIME button the minute digits will flash Press UP or DOWN to adjust the minutes Press the TIME Button to Set Setting the Temperature To change the set temperature press the Up Down button The 2 digit display will indicate the set temperature NOTE Reaching the set temperature depends on the room and outdoor climatic conditions The set temperature range is 64 F to 90 F D Mode Button Press the Mode Button repeatedly until the icon representing the desired mode is displayed Cool or Fan On the LCD display you will see Cooling AB Fan only All settings will remain in memory unless power to the unit is shut off At re start unit will revert back to default temperature setting of 7
8. d 80 above the upper plane of the louvers housing SWING 4 When the louvers are moving in the swing function by pressing the swing push button the louvers stop moving and remain in the same position SWING This enables the user to direct the airflow vertically via the remote control 5 When the OFF push button is pressed the louvers close AUTO GRILL Remote Control To Operate the Remote Control Insert batteries by pulling down on front cover See fig Be sure the remote is pointed at the unit at all times To Set the Clock e Press the TIME button for 3 seconds e The hour digits will flash Press UP or DOWN to adjust the hour e Press the TIME button The minute digits will flash ON OFF UP Press UP or DOWN to adjust the minutes e Press the TIME button when finished FAN DOWN 2 To Turn Unit ON TIMER TIME TIMER e Press the ON OFF button SLEEP MODE 3 To Adjust TEMPERATURE SWING e Adjust temperature using the UP DOWN buttons 4 To Adjust FAN SPEED e Press FAN button to select speed 5 To Set the TIMER A SET START TIME e Press timer ON button and set the On hour using the UP and DOWN buttons e Press timer ON button and set the minutes using Slide the UP and DOWN buttons Cover Down Press timer ON to finish B SET OFF TIME e Press the timer OFF button and set the Off hour using the UP and DOWN button e Press the timer OFF button and set the
9. e contact Amcor for service or technical assistance Amcor Inc www amcorgroupusa com 15 N AMCOR Don t forget to register your Amcor purchase online and view our broad selection of innovative products www amcorgroupusa com 3 2007 N AMCOR One Year Limited Warranty 5 Years for Compressor Only Amcor Inc Amcor warrants the original retail purchaser Purchaser purchasing in the United States that the Amcor product with which this warranty is enclosed is free from defects in materials and workmanship Amcor s sole obligation under this warranty is to replace or at Amcor s discretion to repair free of charge all defective parts for a period of one 1 year from date of original purchase 5 years for Compressor Only ANY IMPLIED WARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITED TO ONE 1 YEAR 5 years for Compressor Only FROM DATE OF ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OTHER WISE MAY BE COMMENCED AFTER EXPIRATION OF ONE 1 YEAR 5 years for Compressor Only FROM DATE OF ORIGINAL RETAIL PURCHASE Some states do not allow limitations on how long an implied warranty lasts so the above limitation 5 years for Compressor Only may not apply to you The provisions of this warranty shall not apply to any product which in Amcor s judgment has been 1 subject to misuse or neglect 2 damaged in accident 3 used for a purpose for which it was
10. f warranty and can endanger the user and property Problem Cause Solution The Air Condi Windows or doors are open Close doors and windows tioner Does Not The filter is dirty Function Properly Clean or replace filter Air inlet or air outlet is blocked Remove blockage Room temperature lower than the Lower temperature selected selected value The Unit Does The overheat protection is activated Wait 3 minutes until temperature has Nothing decreased then turn on again No power supply Make sure outlet works Be sure Green Light is on 1 Plug Press Re start button Is the LCD light flashing Drain the Unit Timer Function Set Deactivate the Timer Function The Unit is Noisy Unit is not standing on a level Place on an even surface surface The Remote Distance too great Make sure the remote is aimed at the Control Does Not control panel Function Remote control signal not detected Control is aimed at the control panel by control panel Batteries are dead Replace the batteries If you have any questions regarding the operation of the this product please contact AMCOR at 1 866 361 2233 REPLACEMENT FILTERS To purchase Replacement Filters for this unit contact AMCOR at 1 866 361 2233 and request model number 12000 If this product is defective or not working properly please DO NOT return to your retail store Pleas
11. orming any maintenance e Make sure the unit is drained before moving Cleaning the Unit e Only use a soft damp cloth e Never use chemicals oil based products detergents or other cleaning solutions These could damage the cabinet Cleaning the Upper Filter Slide out the filter holder from the unit e Separate the filter fixer from the filter holder see fig e Remove the active carbon filter black and slide out the 3M High Air Flow filter white e To clean filters vacuum with standard vacuum cleaner e Insert the active carbon filter into the filter holder see fig 2 e Insert the 3M High Air Flow filter into the filter holder see fig 3 e Fix the filters by reassembling the fixer into the filter holder see fig 4 Cleaning the Lower Filter Vacuum with standard vacuum cleaner NOTE e Before storage be sure filters are clean and dry e Should you need to replace filters contact Amcor for replacement e The screen filter must always be used e The 3M High Air Flow filter should be cleaned periodically Both filters can be vacuumed IMPORTANT NEVER operate the unit without a filter End of Season Storage e Unplug the unit e Drain the condensed water COMPLETELY e Clean the upper and lower filter Troubleshooting Never try to repair or dismantle the air conditioner yourself Tampering with the unit may result in the loss o
12. r treatment We would like you to enjoy the many benefits this unit offers so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Portable Air Conditioner offers you AMCOR has specialized in complete indoor environment control manufacturing world class air conditioners dehumidifiers and air purifiers with innovative technology In designing these advanced products we have listened carefully to our customers and have passed their views on to our research and development laboratories We wish you many years of enjoyable use After reading this manual please keep it in a safe place for future reference Energy Saving Tips e Do not locate the air conditioner where furniture or other objects can obstruct the airflow e Keep doors closed so cool air does not escape e Keep the filters clean Set the unit to maximum cooling and high speed fan initially then adjust the unit to a comfortable setting NOTE Use the Temperature Control UP DOWN to adjust Air Conditioner cooling to a desired level Specifications Model 12000 12000 Cooling Capacity 12 000 BTU hr 12 000 BTU hr Cooling Power Consumption 1 100 W 9 8A 1 100 W 9 8A Heating Capacity 4 000 BTU hr 20 W 16 D x 33 H 20 W 16 D x 33 H REMARKS The cooling capacity of the unit may be affected by the height of the ceiling quality of insulation number of windows etc
13. r cord or place it near a source of heat always unroll it completely to avoid the possibility of dangerous overheating If the power cord is damaged it must be replaced by a qualified person THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED The Unit Air Outlet Control Panel Air Inlet Carrying Handle Exhaust Air Outlet AMCOR Water Stopper A q Castor Wheels Air Filter Pre installed Filter Frame 3M Ch lt D Ca Exhaust Hose Remote Control TA 2 Washable lt Filter E P O Insulation Strip Slide Bar Connector Adjustable Slide Bar Display 4 J SLEEP uP FAN SPEED DOWN SF COOLING MODE HEAT Y TIMER SWING 08 15 HOURS MINUTES 75 F TEMPERATURE Attach Window Slide Bar Connector to Exhaust Hose by twisting as shown Connect the female half of the quick connector at the end of the spiral water pipe to the male part in the hot air outlet pipe Assemble the hot air hose on the unit Unfold flexible hose with attached hose adapter connector and snap into Window Slide Bar AutoDrain NanoMist Technology Assembly Put spiral water pipe into hot air flexible hose Turn the connector 90 degrees clock
14. ustomer Please keep this warranty for your record DO NOT return it 18 913126 10
15. wise until it is locked in place Clip on the water atomizer at the end of the spiral pipe to the holder Only Required For Disassembly In order to unlock the quick connector push the tab and turn the connector 90 degrees counter clockwise Installation of the Window Kit In order for this unit to function properly it must be vented to the outside Fitting the Exhaust Hose through a window is easy Please see below Adjustable Slide Bar Slide Bar Connector Exhaust Hose AMCOR Window Kit Installation A W 7 8 Extend Exhaust Hose at least 6 and insert it into back of the unit tightening into place by turning it clockwise Attach Slide Bar Connector to the other end of the Hose by extending hose at least 6 Then tighten Hose by turning the Slide Bar Connector clockwise Place Adjustable Slide Bar in the window and expand so it fits tightly Mark Slide Bar to record width of the window Apply Insulation Strips on top and bottom of Slide Bar Reposition Slide Bar Connector in the window Expand the Slide Bar to fit tight Tighten the screws Lower the window Make sure Hose has no kinks Slide Bar has 3 sections which allows installation in windows up to 48 in width Installation WARNING The length of the exhaust pipe is specially designed according to the specification of this product Do not extend it with your own hose as this

Download Pdf Manuals

image

Related Search

Related Contents

NucleoBond® PC - MACHEREY  Manuel d´instruction  Mode d`emploi - Leroy Merlin  Graco 306640E User's Manual  COBAN GROUP CO.,LTD  Hi-Q DC controller説明書 - Hi  Cyber Acoustics AC-648 headset  Trendnet TEG-S811FI network switch  Model# 55-0008 SAFETY INSTRUCTIONS  6Parcels User Manual - Amazon Web Services  

Copyright © All rights reserved.
Failed to retrieve file