1. Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room Gas dryers or any dryer located in a closet must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts bird nesting etc The wall cap must also be located at least 12 above the ground or any other obstruction with the opening pointed down Other terminations such as louve red wall boxes are acceptable provided they are equivalent to a 4 opening dampered wall cap Dryer Elbow Kit Pub No 14 A003 is available at additional cost For use with side or bottom exhaust options For more information on venting kits and accessories please call 1 800 GE CARES U Listed by L Underwriters Laboratories For answers to your Monogram GE Profile or GE appliance questions visi GEAppliances com or call t our website at GE
2. Answer Center service 800 626 2000 Profile DPGT750EC GE Profile King size 7 3 Cu Ft Capacity Electric Dryer Specification Revised 3 04 270185 Features and Benefits e Receives load information electronically from the washer WPGT9350 e King size 7 3 cu ft capacity dryer with stainless steel drum and deluxe dryer rack e DuoDry system quickly and consistently dries all types of clothes e LCD electronic controls with time display status lights and cycle countdown with LCD indicators e Variable heater delivers constant heat with no on off cycling for optimal drying results e Adaptive venting system delivers exceptional drying performance e Delicate cycle with extra low setting maintains an average fabric temperature of 125 F to protect fine handwashables e Reversible washer and dryer control panels can be easily interchanged without any loss of function allowing installation flexibility e Multiple dry cycles with 6 custom cycles and Adaptive Logic System e Dual electronic thermistors e Dual motors e Dryer interior light e Model DPGT750ECPL Dark Platinum e Model DPGT750ECWW White on white
3. Profile DPGT750EC GE Profile King size 7 3 Cu Ft Capacity Electric Dryer Dryer Dimensions in inches Exhaust Options lt 22 1 2 gt lt 29 gt 4 way via rear right left and bottom Dryer is shipped exhausted to the rear Right left or bottom exhaust requires a conversion kit NEMA Receptacle codes 3 prong dryer cord 30A 4 long cat WX9X2 is for NEMA10 30R receptacle 4 prong dryer cord 30A 4 long cat WX9X18 is for NEMA14 30R receptacle Circuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Electric Dryer Rating 240V 6000W 28 5A 60Hz Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Side View Rear View Installation Information For complete information see installation instructions packed with your dryer U Listed by L Underwriters Laboratories For answers to your Monogram GE Profile or GE appliance questions visit our website at GEAppliances com or call Specification Revised 3 04 GE Answer Center service 800 626 2000 270185 Profile DPGT750EC GE Profile King size 7 3 Cu Ft Capacity Electric Dryer Dryer Exhausting Information Use Metal Duct Only Dryer Exhausting Information Use Metal Duct Only Vertical and Horizontal Ducting qa Best Performance R Maximu
4. m Length of 4 Maximum Length of 4 A Dia Rigid Metal Duct_ Dia Flexible Metal Duct La 6 Number Exhaust Hood Type Exhaust Hood Type B of 90 A B A B Domestic H Turns 4 Opening 2 1 2 4 Opening 2 1 2 Dryer Models Opening Opening 0 150 ft 75 ft 52 ft 1 140 ft 65 ft 42 ft 2 130 ft 55 ft 32 ft 7 3 Capacity Electric 3 120 ft 45 ft 22 ft and Gas Dryers 4 110 ft 35 ft 12 ft 0 90 ft 55 ft 45 ft 1 60 ft 40 ft 30 ft 7 0 and 6 0 2 45 ft 30 ft 20 ft Capacity Models 3 35 ft 20 ft 15 ft all Electric Dryers 4 25 ft 15 ft 10 ft 0 90 ft 55 ft 45 ft 7 0 and 6 0 1 60 ft 40 ft 30 ft Capacity Models 2 45 ft 30 ft 20 ft all Gas Dryers 3 35 ft 20 ft 15 ft 0 60 ft 48 ft 30 ft 18 ft 1 52 ft 40 ft 22 ft 14 ft 2 44 ft 32 ft 14 ft 10 ft 5 7 Capacity Electric 3 32 ft 24 ft and Gas Dryers 4 28 ft 16 ft Electric dryers only Special Installation Requirements Alcove or Closet Installation 0 either side 3 front and rear Bathroom or Bedroom Installation ational Fuel Gas Code ANSI Z223 The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in the absence of local codes with the f your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be exhausted to the outside inimum clearances between dryer cabinet and adjacent walls or othe
5. r surfaces are inimum vertical space from floor to overhead cabinets ceilings etc is 52 Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed f this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line o other fuel burning appliance shall be installed in the same closet with the dryer Minimum Clearances other than Alcove or Closet Installation e Minimum clearances to combustible 0 both sides 3 rear surfaces Specification Revised 3 04 270185 For complete information see installation instructions packed with your dryer Ducting Materials For best performance this dryer s duct If all rigid metal duct cann hould be vented with 4 diameter all rigid metal exhaust ot be used then flexible all metal venting can be used but it will reduce the maximum recommended duct length Exhaust Length Calculation 1 Determine the number of 90 turns needed for your installation If you exhaust to the side or bottom of dryer add one turn 2 The maximum length of 4 rigid shown in the table The maxim aluminum or galvanized duct which can be tolerated is um length for flexible ducts are less than for rigid duct A turn of 45 or less may be ignored