Home
Broan-NuTone Broan 6", 90 CFM Room to Room Fan, Model 512
Contents
1. but do not distort grilles Bend grille bracket if necessary to make grille flush with wall FIG 6 USE AND CARE DISCONNECT ELECTRICAL POWER SUPPLY BEFORE SERVICING FAN Do not turn on the fan when starting a fire in a fireplace or wood stove until the d Ss amper is thoroughly warm and fully open Turning the fan on too soon may draw moke and flue gases into the room Wait until the fire is well established Always unplug the fan motor before servicing the fan The motor bearings on this fan are lifetime lubricated and will never need oiling Clean the fan blade and motor every six months by removing the grille unplugging the motor and gently vacuuming the fan blade and motor Clean the grille in warm soapy water Use a mild detergent such as a dishwashing liquid DO NOT USE ABRASIVE CLOTHS STEEL WOOL OR SCOURING POW DERS SERVICE PARTS PIEZAS DE SERVICIO Model 512 Modelo 512 eq an PART NO NO PIEZ DESCRIPTION DESCRIPCION conico 99110454 Grille 2 Req Rejilla 99260428 6 32 he Metal Nut Tuercas de l mina met lica 2 Req No 6 32 se necesitan 2 99170245 8B x 3 8 Sheet Metal Tornillos de l mina met lica Screws 3 Req No 8B x 3 8 se necesitan 3 97005322 Motor Mounting Bracket Soporte de montaje del motor 99080199 Motor Motor 99020125 Blade Paleta 98004932 Wiring Box Cover Cubierta de la caja de conexiones 99150471 10 32 x 1 2 Green Ground Tornillo verde de tierra Screw N
2. ET DIRECCI N DEL FLUJO DE AIRE ENTRADA FIG 2 GRILLE REJILLA BRACKET TAB PESTANA DEL SOPORTE FAN HOUSING VRE LA CARCASA DEL VENTILADOR MOUNTING BRACKET SOPORTE DE MONTAJE FIG 3 WIRING BOX JA DE A GREEN OR BARE CONEXIONES WIRE CABLE VERDE O DESCUBIERTO WHITE WIRES CARCASA DEL VENTILADOR FAN HOUSING CARCASA DEL MOUNTING VENTILADOR BRACKET SOPORTE DE MONTAJE H i WIRING BOX 2225 CAJA DE CONEXIONES PANELING PANELADO GRILL N GRILLE CARCASA DEL VENTILADOR PARED FAN HOUSING CARCA A DEL VENTILADOR PLASTER YESO GRILLE BRACKET SOPORTE DE LA REJILLA INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use and Care Information on Page 2 INSTALADOR Deje este manual con el due o de la casa DUENO DE LA CASA Informaci n del uso y cuidado en la p gina 2 MODELO 512 VENTILADOR DE HABITACION A HABITACION LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA ELECTRICA O LESIONES PERSONALES CUMPLA CON LOS SIGUIENTES PUNTOS 1 Solamente use esta unidad de la manera propuesta por el fabricante Si tiene alguna pregunta p ngase en contacto con el fabricante en la direcci n o tel fono anotados en la garant a Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispo
3. ICAL CONNECTIONS 5 6 1 1 1 1 Feed electrical cable to switch and fan Feed cable through wall opening on inlet side of fan and into fan housing FIG 3 Remove knockout on wiring box Fasten electrical cable to wiring box with proper connector for type of wire used Provide 6 leads inside box for electrical con nections Make electrical connections Connect black to black white to white and bare or green wire to box using green ground screw FIG 3 Position fan housing in wall Install wiring box and cover Plug the fan motor into receptacle on wiring box cover Hold fan housing in wall and drill two 3 16 pilot holes through center of two slots in mounting flange FIG 4 Use slots in flange which line up with mounting bracket openings in fan housing O Install mounting brackets from inside of fan housing and pull them tightly against back of wall Make sure tab on bracket is engaged in fan housing FIG 2 1 Insert screws through mounting flange and tighten mounting brackets firmly against wall 2 For walls less than 4 1 2 thick frame out fan housing so that housing is re cessed 1 8 1 4 FIG 5 If fan housing is not flush with edge of wall material lay a thin bead of plaster or patching compound along edge of housing to fill gap between housing and wall FIG 6 3 Spin grilles onto mounting studs Turn on power and check operation of fan Tighten grille flush against wall
4. MODEL 512 ROOM TO ROOM FAN READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnect ing means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a promi nent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all ap plicable codes and standards including fire rated construction codes and standards 4 Sufficient airis needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those pub lished by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 DO NOT CREATE AN OPENING IN A FIRE RATED WALL TO INSTALL THIS FAN Itis n
5. TE QUE VA AL ENCHUFE ANTES DE HACER CONEXIONES ELECTRICAS EN ESTE 5 Pase el cable el ctrico al interruptor y al ventilador Pase el cable a trav s de la abertura de la pared en el lado de la entrada del ventilador y hacia dentro de la carcasa del ventilador FIG 3 6 Quite el disco removible en la caja de conexiones Sujete el cable el ctrico a la caja de conexiones con el conector que corresponde para el tipo de cable que se use Deje conductores de 15 24 cm 6 plg hacia el interior de la caja para hacer las conexiones el ctricas 7 Haga las conexiones el ctricas Conecte el cable negro con el negro el blanco con el blanco y el verde o descubierto a la caja usando el tornillo de tierra FIG 3 8 Coloque la carcasa del ventilador en la pared Instale la caja de conexiones y la tapa Conecte el motor del ventilador en el enchufe en la tapa de la caja de conexiones 9 Sujete la carcasa del ventilador en la pared y taladre dos agujeros pilotos de 4 8 mm a trav s del centro de las dos ranuras en el borde de montaje FIG 4 Use las ranuras en el borde que se alinean con las aberturas de los soportes de montaje en la carcasa del ventilador 10 Instale los soportes de montaje desde el interior de la carcasa del ventilador y tire de ellas fuertemente hacia el fondo de la pared Conpruebe de que la pesta a en el soporte est enganchado en la carcasa del ventilador 11 Inserte los tornillos a trav s del borde de montaje y apri
6. a impl cita por lo que la limitaci n antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE BROAN NUTONE DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA BROAN NUTONE NO SERA RESPONSABLE POR DA OS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES QUE SURJAN A AIZ DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores ara calificar en la garant a de servicio usted debe a notificar a Broan NuTone al domicilio que se menciona abajo o al tel fono 1 800 637 1453 b dar el n mero del modelo y la identificaci n de la pieza y c describirla naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra Broan NuTone LLC 926 West State Street Hartford WI 53027 U S A 1 800 637 1453 Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 99040925G
7. ador el motor y la carcasa Limpie las rejillas en agua caliente enjabonada NO USE TELAS ABRASIVAS ESPONJILLAS DE LANA DE ACERO NI POLVOS ABRASIVOS GARANTIA BROAN NUTONE LIMITADA POR UN A O Broan NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio Broan NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS LUORESCENTES Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan causado un accidente o que hayan sido reparadas o mantenidas inapropiadamente por otras compa as que no sean Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant
8. epair otherthan by Broan NuTone faulty installation orinstallation contrary to recommended installation instructions he duration ofany implied warranty is limited to the one year period as specified forthe express warranty Some states do notallow imitation on how long an implied warranty lasts so the above limitation may notapply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE ATBROAN NUTONE S OPTION SHALLBETHEPURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIALOR SPECIALDAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCTUSE OR PERFORMANCE Somestates do notallow the exclusion orlimitation ofincidentalor consequential damages so the above limitation orexclusion may not apply to you his warranty gives you specific legal rights and you mayalso have other rights which vary fromstate to state This warranty supersedes allpriorwarranties o qualify forwarranty service you must a notify Broan NuTone atthe address stated below ortelephone 1 800 637 1453 b give the model numberand partidentification and c describe the nature ofany defectinthe productor part Atthe time ofrequesting warranty service you mustpresentevidence ofthe original purchase date Broan NuTone LLC 926 WestState Street Hartford WI 53027 1 800 637 1453 3 Saque la caja de conexiones del ventilador 4 Determine la direcci n deseada del aire FIG 2 ADVERTENCIA DESCONECTE LA CORRIEN
9. ete los soportes firmemente contra la pared 12 Para paredes de menos de 11 43 cm 4 1 2 plg de grosor coloque un marco alrededor de la carcasa de manera que quede empotrado de 3 2 a 6 3 mm de 1 8 a 1 4 plg FIG 5 Si la carcasa del ventilador no est a nivel del borde del material de la pared coloque una fina capa de masilla o yeso a lo largo del borde de la carcasa para llenar el hueco entre la carcasa y la pared FIG 6 13 Gire las rejillas en los pasadores de montaje Conecte la corriente y compruebe el funcionamiento del ventilador Apriete la rejilla contra la pared sin deformarla Si es necesario doble el soporte de la rejilla hasta que sta quede al nivel con la pared FIG 6 USO Y CUIDADO DESCONECTE LA CORRIENTE ELECTRICA ANTES DE REPARAR EL VENTILADOR No encienda el vetilador mientras est usando una chimenea o una estufa de madera hasta que el humidificador est totalmente caliente y completamente abierto La acci n de conectar el ventilador demasiado pronto puede dirigir el humo o gases dentro de la habitaci n Espere hasta que el fuego est bien dispuesto Desconecte siempre el motor del ventilador antes de reparar el ventilador Los cojinetes del motor en este ventilador est n lubricados de por vida y nunca necesitar n lubricaci n Limpie la la paleta del ventilador y el motor cada seis meses retirando la rejilla desenchufando el motor y pasando un aspirador suavamente por la paleta y motor del ventil
10. ldores ruidosos o desequilibrados mantenga la fuente de potencia lejos de roc os de pared seca de polvo de construcci n etc Lea la etiqueta de especificaciones del producto para m s informaci n y requisitos HERRAMIENTAS Y MATERIALES NECESARIOS A L piz y regla o cinta m trica 1 Destornillador de hoja recta 1 Broca de 0 48 cm 3 16 plg 1 Taladro el ctrico o de trinquete U Alicates T Sierra de pared seca o sierra en punta 1 Art culos el ctricos del tipo necesario para cumplir con los c digos locales INSTA RACI N DEL VENTILADOR 2 Planifique la instalaci n El ventilador se puede instalar en paredes de hasta 13 02 cm 5 1 8 plg degrosor para paredes de menos de 11 43 cm 4 1 2 plg se requiere un contramarco delgado espaciador vea paso 13 E ventilador puede ser controlado con un interruptor de pared o con un control de velocidad disponible por separado Corte con cuidado las aberturas en el ventilador y la abertura de la caja de conexiones FIG 1 PRECAUCION NO OLVIDE QUE TIENE QUE MEDIR Y MARCAR EL CENTRO DE LA ABERTURA DEL VENTILADOR EN LA PARED CONTRARIA ANTES DE CORTAR CUALQUIERA DE LAS ABERTURAS ADVERTENCIA CUANDO CORTE O TALADRE A TRAVES DE LA PARED TENGA CUIDADO DE NO CORTAR EL CABLEADO ELECTRICO EXISTENTE 3 4 Remove wiring box from fan Determine desired air flow direction FIG 2 WARNING DISCONNECT ELECTRICAL POWER TO OUTLET YOU ARE TAP PING INTO BEFORE MAKING ELECTR
11. o 10 32 x 1 2 98005329 Wiring Box Caja de conexiones 97007603 Housing Carcasa 99260485 8B Sheet Metal Nut Tuerca tipo U de l mina met lica U Type 2 Req No 8B se necesitan 2 99420497 Mounting Bracket 2 Req Soporte de montaje se necesitan 2 99170262 8B x 1 1 4 Pan Head Screw Tornillos de cabeza plana 2 Req No 8B x 1 1 4 se necesitan 2 99270982 Receptacle Enchufe Standard Hardware May be purchased locally Material est ndar Puede ser adquirido 3 4 5 6 7 8 9 a y tad wm m A pn A localmente Order service parts by Part No NOT by Key No Encargue piezas de servicio por No Piez NO por No Codigo BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaserofits products thatsuch products will be free from defects in materials or workmanship fora period ofone year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR MPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Duringthis one year period Broan NuTone will atits option repairor replace withoutcharge any productor partwhich is found to be defective undernormaluse and service HIS WARRANTY DOES NOTEXTENDTOFLUORESCENT LAMP STARTERS ANDTUBES This warranty does notcover a normal maintenance and service or b any products or parts which have been subjectto misuse negligence accident impropermaintenance orr
12. otan exhaust fan rather it is intended to direct air from one room to another 7 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and va pors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray con struction dust etc off power unit 3 Please read specification label on product for fur ther information and requirements TOOLS AND MATERIALS REQUIRED 1 Pencil and ruler or tape measure T Straight blade screwdriver A 3 16 drill bit T Drill electric or ratchet drive d Pliers 1 Drywall saw or saber saw a Electrical supplies of type to comply with local codes INSTALL THE FAN 1 Plan installation Fan will install in walls up to 5 1 8 thick For wall less than 4 1 2 thick a trim board frame for spacing is required see Step 13 Fan can be controlled by a wall switch or speed control available separately 2 Carefully cut out fan openings and switch box open ing FIG 1 CAUTION BE SURE TO MEASURE AND MARK CENTER OF FAN OPENING ON OPPOSITE WALL BEFORE CUTTING OUT EITHER OPENING WARNING WHEN CUTTING OR DRILLING INTO WALL BE CAREFUL NOT TO CUT EXISTING ELEC TRICAL WIRING SWITCH OR SPEED CONTROL INTERRUPTOR O CONTROL DE VELOCIDAD WALL OUTLET r ENCHUFE L NTILADOR FAN HOUSING FLANGE BORDE DE LA CARCASA DEL VENTILADOR AIRFLOW DIRECTION INL
13. sitivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente El trabajo de instalaci n y el alambrado el ctrico deben de llevarse a cabo por personal competente de acuerdo con todos los c digos y las normas correspondientes incluyendo los c digos y normas de construcci n contra incendios Se requiere una cantidad de aire suficiente para la combusti n y expulsi n de gases por la chimenea en el equipo de quemado de combustible para evitar la retrogresi n de la llama Siga las especificaciones del fabricante del equipo de calefacci n y las normas de seguridad semejantes a las publicadas por la Asociaci n nacional de protecci n contra incendios NFPA por sus siglas en ingl s y la Sociedad americana de ingenieros de calefacci n refrigeraci n y aire acondicionado ASHRAB y los c digos de las autoridades locales Cuando corte o taladre en una pared o techo no da e el alambrado el ctrico u otras instalaciones ocultas NO HAGA UNA ABERTURA EN UNA PARED REFRACTARIA PARA INSTALAR ESTE VENTILADOR Este ventilador no es un ventilador extractor sino para hacer circular el aire de una habitaci n a otra Esta unidad debe ser conectada a tierra PRECAUCION Solamente para uso de ventilaci n general No se use para extraer materiales ni vapores peligrosos o explosivos Para evitar da os al cojinete del motor y o impu