Home
GE DCD330EB Electric Dryer
Contents
1. E Remove all sharp packing items and dispose of all shipping materials properly E In fulfilling the specific needs of different commercial installations the purchaser of this dryer may wish to locate the coin box and controls in any of a number of locations The responsibility for the proper performance of this work lies solely with the purchaser It should be done by properly trained and qualified personnel and in accordance with local code requirements E Any coin box or similar device added to the dryer either electrically or mechanically should be properly grounded E Remove any accumulated time by manually rotating timing cam in the coin box counterclockwise until switch shuts off Apply a slight additional counterclockwise pressure to further seat drive Make certain not to turn cam past switch shutoff position Otherwise one increment of time will be gained Switches are off when the plastic switch actuating arm inner is down and all 3 switch buttons are depressed Exhaust Ducting 7 This dryer MUST be exhausted to the outside 2 Use only rigid metal or flexible metal 4 diameter ductwork inside the dryer cabinet or for exhausting to the outside USE OF PLASTIC OR OTHER COMBUSTIBLE DUCTWORK CAN CAUSE A FIRE PUNCTURED DUCTWORK CAN CAUSE A FIRE IF IT COLLAPSES OR BECOMES OTHERWISE RESTRICTED IN USE OR DURING INSTALLATION Follow details in the nstallation Instructions section suoyaonysuy A
2. Commercial Dryers GEAppliances com Safety Instructions Care and Cleaning Care and Cleaning Installation Instructions Countdown Display Electrical Installation for Electric Dryers 2 ae ce ees Electrical Requirements Exhausting the Dryer Owner s Manual and Installation Instructions EA 6 DCB330 DCD330 Gas Connection for Gas Dryers 15 Gas Supply Requirements Location of Your Dryer Mobile Home Installation Preparing to Install Your Dryer 7 Reversing the Door Swing 16 Customer Service Customer Service Back Cover General Principles of Good Practice 19 Warranty 0 eee eee 18 Write the model and serial numbers here Model Serial You can find them on the label on the front of the left side of the door opening 134205200 175D1807P420 49 90156 11 02 JR IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING A WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or death Safety Instructions Installation and service must be performed by a qualified installer service agency or the gas supplier FOR GAS DRYERS YOU MUST POST IN A PROMINENT LOCATION 1 Instructions to follow if the user smells gas Contact your local gas supplier for information to be displayed 2 I
3. RNI N G Use copper receptacles only NOTE Dryers operating on 208 volt power supply will have longer drying times than those operating on 240 volt power supply A wiring diagram is located inside the control panel 13 suon nysuj Ajajes J9 pue aie Guiuea a A q Q 3 A S Q S 77 J WOJSNI aIINa Safety Instructions Care and Cleaning i S S 5 O S 3 S lt S 3 rvice Customer Se Installing the dryer 3 Wire System for Electric Dryers DO NOT use for Mobile Home Installations 14 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a ULdisted strain relief into the power cord entry hole of the mounting bracket Use a strain relief which attaches to the mounting bracket with a nut Finger tighten the nut only at this time Thread a UL listed 30A 240V 3 10 AWG minimum copper conductor power cord through the strain relief Power cord leads to be terminated with open end spade lugs with upturned ends Green ground screw Green neutral ground wire Tighten nut to these threads Use copper Power cord conductors only Strain relief mounting bracket Attach the power cord neutral center wire conductor to the silver colored center terminal on the terminal block Tighten the screw securely Attach the remain
4. ce of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 Electrical Requirements e This dryer must be supplied with 120V 60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse e If the electric supply provided does not meet the above specifications it is recommended that a licensed electrician install an approved outlet Ensure proper ground exists before use External Ground if required An external ground wire not provided which meets local codes may be added by attaching it to the green ground screw on the rear of the dryer in the upper left corner above the cord and to grounded metal cold water pipe or other established ground Attach ground wire obtain locally NOTE A wiring diagram is located inside the control panel Exhausting the dryer Exhaust System Requirements Use only 4 10 2 cm diameter minimum rigid metal duct for best performance or flexible metal duct Use approved vent hood which has swing out dampers that open when the dryer is in operation When the dryer stops the dampers automatically close to prevent drafts and the entrance of insects and rodents To avoid restricting the outlet maintain a minimum of 12 30 5 cm clearance between the vent hood and the ground or any other obstruction If all rigid metal duct cannot be used then flexible all meta
5. d brass Same as EXHAUST DUCT LOCATING other side DIMENSIONS 57 8 i ai 3 3 4 9 5 Aii T 3 4 9 5 cm A The gas supply line MUST have an individual shutoff valve 5 A 1 8 0 32 cm NPT minimum plugged tapping accessible for test gauge connection MUST be installed immediately upstream of the gas supply connection to the dryer 6 The dryer and its individual shutoff valve MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1 2 psig 3 45 kPa 7 The dryer MUST be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Location of Your Dryer Do Not Install the Dryer Do not install the dryer in an area exposed to Do not install the dryer on carpet dripping water or outside weather conditions Floor MUST be solid with a maximum slope 2 Do not install the dryerin an area where it will of 1 2 54 cm come in contact with curtains drapes or anything that will obstruct the flow of combustion and ventilation air suon nysuj Majes Installation in Recess or Closet 7 This dryer MUST be exhausted outdoors Allow the following clearances for ease o
6. d ground wire to the cabinet with the green ground screw Attach the white neutral power cord conductor from the power cord and the green ground wire from the dryer harness to the silver colored center terminal on the terminal block Tighten the screw securely 7 Attach the red and black power cord conductors to the outer brass colored terminals on the terminal block Green power cord ground wire Green ground screw Green neutral 1 ground wire eo Red 1 AE Tighten nut to these threads mounting bracket A WARNING Do not make a sharp bend or crimp wiring conductor at the connections 9 Tighten the screws securing the cord restraint firmly against the power cord Tighten the strain relief nut securely so the strain relief does not turn 70 Reinstall the terminal block access cover CI Gas Connection for Gas Dryers Z Remove the shipping cap from gas pipe at the rear of the dryer NOTE DO NOT connect the dryer to LP gas service without converting the gas valve An LP conversion kit Pub No 14 4038 MUST be installed by a qualified gas technician 2 Connect a 1 2 1 27 cm I D semirigid or approved pipe from gas supply line to the 3 8 0 96 cm pipe located on the back of the dryer Use a 1 2 to 3 8 1 27 cm to 0 96 cm reducer for a connection Apply an approved thread sealer that is resistant to the corro
7. ded warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 800 626 2002 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Contact Us GEAppliances com KoA Ifyou are not satisfied with the service you receive from GE contact us on our Website with all the details including your phone number or write to General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 Register Your Appliance GEAppliances com Register your new appliance on line at your convenience Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty should the need arise You may also mail in the pre printed registration card included in the packing material Printed in the United States
8. e in contact with exhaust system The dryer MUST NOT be exhausted into a gas vent chimney a wall a ceiling a common duct with a kitchen exhaust or any concealed space of a building which can accumulate lint resulting in a fire hazard A DO NOT exceed the length of duct pipe or number of elbows allowed in the Maximum Length charts Lint can accumulate in the exhaust system plugging the system and creating a fire hazard as well as increasing drying times A DO NOT screen the exhaust ends of the vent system nor use any screws or rivets to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with duct tape All male duct pipe fittings MUST be installed downstream with the flow of air A EXPLOSION HAZARD Do not install the dryer where gasoline or other flammables are kept or stored If the dryer is installed in a garage it must be a minimum of 18 45 7 cm above the floor Failure to do so can result in death explosion fire or burns gt gt gt Provide an access for inspection and cleaning of the exhaust system especially at turns Inspect and clean at least once per year Do not obstruct incoming or exhausted air The following directions must be followed e Use the shortest length possible S
9. e the static electricity in them by using a dryer applied fabric softener or an anti static conditioner We recommend you use either a fabric softener in the wash cycle according to the manufacturer s instructions for those products or try a dryer added product for which the manufacturer gives written assurance on the package that their product can be safely used in your dryer Service or performance problems caused by use of these products are the responsibility of the manufacturers of those products and are not covered under the warranty to this appliance duct connection inside the dryer should be cleaned at least once a year by a qualified technician See the Care and Cleaning section Do not use any type of spray cleaner when cleaning dryer interior Hazardous fumes or electrical shock could occur H If yours is a gas dryer it is equipped with an automatic electric ignition and does not have a pilot light DO NOT ATTEMPT TO LIGHT WITH A MATCH Burns may result from having your hand in the vicinity of the burner when the automatic ignition turns on WHEN NOT USING YOUR DRYER gt E Grasp the plug firmly when disconnecting this appliance to avoid damage to the cord while pulling Place the cord away from traffic areas so it will not be stepped on tripped over or subjected to damage E Before discarding a dryer or removing it from service remove the dryer door to prevent children from hiding inside E Do not tamper wit
10. ed infringement is based on a patent claim including one or more components added by the purchaser i e not supplied by General Electric Company with the purchased dryer Set forth below are some general principles which should be followed by persons installing the coin box and controls in the desired location This listing is not all inclusive and is only intended to serve as a general guide These principles are intended to supplement not modify the Installation Instructions which accompany the automatic dryer 1 Any component added to the automatic dryer either electrically or mechanically should be properly grounded 2 All current carrying metal parts should be isolated from possible contact by the user 3 All wiring should be properly protected from sharp edges burrs moving parts and other agencies which might cause abrasion of the insulation on the conductors All electrical connections should be mechanically secure and should provide adequate and reliable electrical contact under conditions such as vibration to which they may be subjected All electrical components wires and terminals should be of proper electrical rating for the specific application All insulating materials should remain effective under the specific conditions to which they will be exposed e g humidity temperature etc The installation should not be incompatible with the electrical circuit within the automatic dryer nor in any manne
11. efore the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn the dryer off and wait 5 minutes before making another attempt to light A CA U TI ON Before operating the dryer make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 3 Run the dryer through a cycle check for proper operation 6 Place these instructions in a location near the dryer for future reference A WARNING The instructions in the manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUSTbe applied when installing operating and maintaining any appliance 15 suoyonysuy ajes J9 pue aie uuega A 9 gt Q 3 A S Q S 77 49WI0 SN aIINa Installing the dryer Open the dryer door Remove the 4 hinge hole plugs or screws from the left side of door a opening Place nearby for future installation NOTE You may need a plastic knife to help pull out the plugs Be careful not to scratch the paint Safety Instructions 2 Remove the four scre
12. en servicing controls Wiring errors can cause improper and dangerous operation verify proper operation after servicing installation Customer Se 12 ai ef Grounding Requirements A WARNIN G Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded Grounding must be in accordance with local codes and ordinances or in the absence of local codes in accordance with the National Electrical Code ANSI NFPA No 70 For a grounded cord connected electric dryer 7 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by creating a path of least resistance for electrical current 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances fin doubt call a licensed electrician For a permanently connected electric dryer E The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance For a cord connected gas dr
13. f installation gt Lf 2 No other fuel burning appliance shall be FRONT SIDES REAR TOP installed in the same closet as the GAS DRYER 1 254cm 0 0cm 17 254cm 15 38 1 cm S l Q 3 Your dryer needs the space around it for Additional rear clearance may be required depending O proper ventilation DO NOT INSTALL YOUR on the ducting installation o DRYER IN A CLOSET WITH A SOLID DOOR 2 4 Closet doors must be louvered or otherwise S ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable 1 2 54 cm a A D q Q 3 A S Q S 7 BGO sq in 387 1 sq cm Closet door J WOJSNI aIINa 11 Safety Instructions Care and Cleaning S Ss S A S S amp 3 Installing the dryer Mobile Home Installation 7 Dryer MUST be exhausted outside outdoors 6 not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 10 16 cm in diameter with no obstructions Rigid metal duct is preferred 2 If dryer is exhausted through the floor the ex
14. h controls E Do not attempt to repair or replace any part of this appliance or attempt any servicing unless specifically recommended in this Owner s Manual or in published user repair instructions that you understand and have the skills to carry out READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY Q SAVE THESE INSTRUCTIONS suononysuy Ajajes J9 pue ase 6uiuea A z D Q 3 A S Q 5 a J9UIO SN aIINa Care and cleaning S S I cos SA Care and Cleaning of the Dryer W SS S D The Exterior Wipe or dust any spills or washing The Exhaust Duct Inspect and clean the exhaust D 6 compounds with a damp cloth Dryer control ducting at least once a year to prevent clogging amp panel and finishes may be damaged by some A partially clogged exhaust can lengthen the A laundry pretreatment soil and stain remover drying time products Apply these products away from the dryer The fabric may then be washed and dried Follow these steps normally Damage to your dryer caused by these 7 Turn off electrical supply by disconnecting the products is not covered by your warranty plug from the wall socket The Lint Filter Clean the lint filter before each 2 Disconnect the duct from the dryer we T PREN ioe E ee Vacuum the duct with the hose attachment and to remove lint Do not operate the dryer without the lint filter in place Peon eC ibe duet The Exhaust Hood Check
15. haust system must NOT terminate beneath the mobile home Termination MUST be securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 Gas dryers MUST be fastened to the floor using Mobile Home Installation Kit Pub No 14 D346 33 5 See the Exhaust System Requirements section for other important venting information Installation MUST conform to current Manufactured Home Construction amp Safety Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes ANSI NFPA No 501B Correct The dryer is designed for use under ANSI Z 21 5 1 Rough In Dimensions lt 267 8 68 3 cm Flectrical connection 2 9 16 lt 1 1 120 7 cm Door open 90 6 5 cm 43 5 8 nes 110 7 cm 43 8 36 11 1 cm O 91 5 cm Optional vent knockout t 3 8 0 96 cm Dia i z ft ss 33 4 gas pipe 1 2 54 cm 68 6 cm 33 4 2 9 5 cm 9 5 cm gt REAR VIEW SIDE VIEW Servicing Consideration must be given to provide adequate clearances for installation and servicing A CA U Tl ON Label all wires prior to disconnection wh
16. in a location where they will be noticed by the owner Packing Safety Instructions Care and Cleaning S S S 3 Ss amp rvice Customer Se Electrical requirements Read these instructions completely and carefully Flectrical Connection Information for Electric Dryers A WARNIN To reduce the risk of fire electric shock or personal injury e DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE e THIS APPLIANCE MUST BE PROPERLY GROUNDED This dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 Electrical Requirements e This dryer must be connected to a 208V or 240V individual branch circuit protected by 30 amp circuit breakers or time delay fuses e Use copper conductors only e If the electric supply does not meet the above specifications call a licensed electrician NOTE A wiring diagram is located inside the control panel Electrical Connection Information for Gas Dryers d A WARNING_ reduce the risk of fire electric shock or personal injury e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE e DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUNDING PRONG FROM THE POWER CORD This dryer must be electrically grounded in accordance with local codes and ordinances or in the absen
17. ing two power cord outer conductors to the outer brass colored terminals on the terminal block Tighten both screws securely A WARNING Do not make a sharp bend or crimp wiring conductor at connections 6 Reattach the strain relief mounting bracket to the back of the dryer with one screw Tighten screw securely Tighten the screws securing the cord restraint firmly against the power cord 8 Tighten the strain relief nut securely so that the strain relief does not turn Reinstall the terminal block access cover 4 Wire System for Electric Dryers MUST be used for Mobile Home Installations 7 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a UL listed strain relief in the entry hole of the mounting bracket Use a strain relief which attaches to the mounting bracket with a nut Finger tighten the nut only at this time 3 Remove the green neutral ground wire from the green ground screw located above the terminal block Typical 4 Black 240V conductor Typi ypical White neutral receptacle 4 conductor cord Red 240V Green ground Thread a Ulisted 30A 240V 4 10 AWG minimum copper conductor power cord through the strain relief Power cord leads to be terminated with open end spade lugs with upturned ends Attach the green power cor
18. intended purpose defects with this appliance This warranty is extended to the original purchaser and any succeeding owner for products purchased for commercial use within the USA In Alaska the warranty excludes the cost of shipping to your place of business Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 A S S S z S 2 rvice Customer Se 18 AUTOMATIC DRYER COMMERCIAL APPLICATION GENERAL ELECTRIC DRYERS GENERAL PRINCIPLES OF GOOD PRACTICE COIN OPERATED MODELS ONLY In fulfilling the specific needs of different commercial installations the purchaser of this General Electric automatic dryer may wish to locate the coin box and controls in any of a number of locations The responsibility for the proper performance of this work lies solely with the purchaser It should be done by properly trained and qualified personnel and in accordance with local code requirements In addition General Electric Company assumes no responsibility or liability whatsoever to the purchaser for any patent infringement expenses either in the form of damages or legal costs where the alleg
19. ions POL oin i app aons Such as E a va or beauty salons etc 9Y of gas appliances in garages They must be 18 S Q gt i D Tools and Materials Required for Dryer Installation S 5 L Phillips head screwdriver Q Rigid or flexible metal 4 10 2 cm duct eQ Q Adjustable pliers Q Vent hood Q Carpenter s level L Pipe thread sealer GAS DRYER Q Flat or straight blade screwdriver Q Duct tape Preparing the Installation Site and Unpacking the Dryer 7 Prepare the area and exhaust for installation A C A UTIO N Topenie of the new dryer do not use the control panel as a means 2 Check to be sure that the existing external to pick up or move the dryer exhaust is clean and that it meets attached eee i Return the dryer to an upright position installation specifications 4 A 9D gt Q 3 Pd S Q S 77 3 Using the four shipping carton corner posts 3 Move the dryer to the desired location as padding two on each side carefully lay the dryer on its left side and remove foam A Connect the external exhaust shipping pad N Z Adjust the leveling legs to match the washer height The dryer must be level and rest firmly on all four leveling legs 8 Connect the power supply 9 Check the operation of the power supply Foam shipping pad ae venting J WOJSNI aIINa ig Place the Owner s Manual and the Installation Instructions
20. jajes J3 pue aie uuea 2 2 Q 3 2 S 2 S 7 1 WOJSNI aIINa Safety Instructions Care and Cleaning S S lt S amp rvice Customer Se IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING A WARNING YOUR LAUNDRY AREA E Keep the area underneath and around your appliances free of combustible materials such as lint paper rags chemicals gasoline and other flammable vapors and liquids H Keep the floor around your appliances clean and dry to reduce the possibility of slipping E Keep area around the exhaust opening and surrounding areas free from the accumulation of lint dust and dirt E Do not obstruct the flow of ventilating air Do not stack or place laundry or throw rugs against the front or back of the dryer WHEN USING YOUR DRYER E Close supervision is necessary if this appliance is used by or near children Do not allow children to play on with or inside this or any other appliance Mi Keep all laundry aids such as detergents bleaches etc out of the reach of children preferably in a locked cabinet Observe all warnings on container labels to avoid injury H Never climb on or stand on the dryer top E Do not install or store this appliance where it will be exposed to the weather E Never reach into the dryer while the drum is moving Before loading unloading or adding clothes wait until the dr
21. l venting can be used but it will reduce the maximum recommended duct length See Additional Installation Instructions following Correct c L A WARNIN Gr The following are specific requirements for proper and safe operation of your dryer Failure to follow these instructions can create excessive drying times and fire hazards A DO NOT use plastic flexible duct to exhaust the dryer Excessive lint can build up inside exhaust system and create a fire hazard and restrict air flow Restricted air flow will increase drying times If your present system is made up of plastic duct or metal foil duct replace it with rigid or flexible metal duct Ensure the present duct is free of any lint prior to installing dryer duct Additional Ducting Instructions If all rigid metal duct cannot be used then flexible all metal venting can be used but it will reduce the maximum recommended duct length In special installations when it is impossible to make a connection with the above recommendations then UL listed clothes dryer transition duct may be used as transition venting between the dryer and wall connection only The use of this ducting will affect drying time If flexible transition duct is necessary only UL listed duct identified for use with clothes dryers is approved The dryer exhaust system MUST BE EXHAUSTED TO THE OUTSIDE DO NOT allow combustible materials for example clothing draperies curtains paper to com
22. materials when heated can under certain circumstances produce fire by spontaneous combustion E Do not store plastic paper or clothing that may burn or melt on top of the dryer during operation E Garments labeled Dry Away from Heat or Do Not Tumble Dry such as life jackets containing Kapok must not be put in your dryer E Do not dry fiberglass articles in your dryer Skin irritation could result from the remaining particles that may be picked up by clothing during subsequent dryer uses E To minimize the possibility of electric shock unplug this appliance from the power supply or disconnect the dryer at the distribution panel by removing the fuse or switching off the circuit breaker before attempting any maintenance or cleaning except the removal and cleaning of the lint filter MOTE Turning the Cycle Selector knob to an off position does NOT disconnect the appliance from the power supply E Do not spray any type of aerosol into on or near dryer at any time E Do not place items exposed to cooking oils in your dryer Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire E Never attempt to operate this appliance if it is damaged malfunctioning partially disassembled or has missing or broken parts including a damaged cord or plug E The interior of the machine and the exhaust GEAppliances com H You may wish to soften your laundered fabrics or reduc
23. ml lt lt 60 18 28 m 48 14 63 m 52 15 84m 40 12 19m WwMmam 3 975m 3 32 Om W 031m 4 BY 853m 16 487m 4 10 2 cm Louvered Number of 90 turns Pa 6m 2 ft 427m 10 3 05 3 not recommended INSTALL MALE FITTINGS IN CORRECT DIRECTION Exhaust Direction All dryers are shipped set up for rear exhausting On electric dryers exhausting can be on the cabinet right or left side or through the dryer bottom Gas dryers can exhaust on the cabinet right side or the dryer bottom To change exhaust direction you will need Exhaust Kit Pub No 14 A018 and a rigid metal 4 90 degree elbow The kit is available through your GE retailer Follow the instructions supplied with the kit a N A Replace brass connecting pipe that is not N plastic coated Stainless steel or plastic coated brass MUST be used WARNIN G Never reuse old flexible connectors The use of old flexible connectors can cause gas leaks and personal injury Always use NEW flexible connectors when installing a gas appliance Installation MUST conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 latest edition The gas supply line should be of 1 2 1 27 cm rigid pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The 10 tubing MUST be constructed of stainless steel or plastic coate
24. nstructions concerning flammable materials as follows FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Care and Cleaning California Safe Drinking Water and Toxic Enforcement Act This act requires the governor of California to publish a list of substances known to the state to cause cancer birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances Gas appliances can cause minor exposure to four of these substances namely benzene carbon monoxide formaldehyde and soot caused primarily by the incomplete combustion of natural gas or LP fuels Properly adjusted dryers will minimize incomplete combustion Exposure to these substances can be minimized further by properly venting the dryer to the outdoors S Ss S 3 amp Ss amp Customer Service PROPER INSTALLATION GEAppliances com This dryer must be properly installed and located in accordance with the Installation Instructions before it is used E Properly ground dryer to conform with all governing codes and ordinances Follow details in the nstallation Instructions section Mi Install or store where it will not be exposed to temperatures below freezing or exposed to the weather E Connect to a properly rated protected and sized power supply circuit to avoid electrical overload
25. r interfere with either the safety devices or the sequence of operations of the cycle which are engineered into the appliance Uninsulated current carrying metal parts should have adequate and ensured permanence of spacing from other parts 19 Consumer Support GE Appliances Website GEAppliances com Have a question or need assistance with your appliance Try the GE Appliances Website 24 hours a day any day of the year For greater convenience and faster service you can now download Owner s Manuals order parts catalogs or even schedule service on line You can also Ask Our Team of Experts your questions and so much more Schedule Service GEAppliances com Expert GE repair service is only one step away from your door Get on line and schedule your service at your convenience 24 hours any day of the year Or call 800 GE CARES 800 432 2737 during normal business hours Real Life Design Studio GEAppliances com GE supports the Universal Design concept products services and environments that can be used by people of all ages sizes and capabilities We recognize the need to design for a wide range of physical and mental abilities and impairments For details of GE s Universal Design applications including kitchen design ideas for people with disabilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Extended Warranties GEAppliances com Purchase a GE exten
26. rts and service are available from your General Electric Staple your receipt here S Commercial Laundry distributor Proof of the original purchase date is needed to obtain service 2 under the warranty z amp For The Period Of We Will Replace a Three Years Any part of the dryer which fails due to a defect in materials or workmanship During this From the date of the limited three year warranty you will be responsible for any labor and related service costs original purchase Five Years The dryer drum if it should fail due to a defect in materials or workmanship and the cabinet side From the date of the panels base and cover if they should fail due to rust through During this limited additional two original purchase year warranty you will be responsible for any labor and related service costs gt What Is Not Covered A amp H Coin drop meter coin slide mechanism coin vault and E Any and all implied warranties of merchantability and locks smart card modules and cards smart card system fitness for a particular purpose S E E Replacement of fuses or resetting of circuit breakers at H Service trips to your place of business to teach you how place of business a amp Tene Erodes E Damage to the product caused by accident fire floods or E Improper installation acts of God H Failure of the product if it is abused misused or used H Incidental or consequential damage caused by possible for other than the
27. sive action of liquefied gases on all pipe connections Before Operating the Dryer Connect the exhaust duct to outside exhaust system Use duct tape to seal all joints With the dryer in its final position adjust one or more of the legs until the dryer is resting solidly on all four legs Place a level on top of the dryer THE DRYER MUST BE LEVEL AND RESTING SOLIDLY ON ALL FOUR LEGS 3 Plug the power cord into a grounded outlet NOTE Check to ensure the power is off at circuit breaker fuse box before plugging the power cord into the outlet Turn on the power at the circuit breaker fuse box Replacement Parts If replacement parts are needed for your dryer contact the source where you purchased your dryer CA U TI ON Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNIN G Destroy the carton and plastic bags after the parts are unpacked Children might use them for play Cartons covered with rugs bedspreads or plastic sheets can become airtight chambers causing suffocation Place all materials in a garbage container or make materials inaccessible to children 3 Open the shutoff valve in the gas supply line Test all connections by brushing on a soapy water solution A WARNING never test ror cas LEAKS WITH AN OPEN FLAME NOTE On gas dryers b
28. tretch the duct to its maximum length e Do not crush or collapse e Never use transition duct inside the wall flooring ceiling or inside the dryer e Avoid resting the duct on sharp objects e Venting must conform to local building codes suoyonysuy Ajajes J9 pue ase uuega A a Q 3 A S Q S 77 1 WOJSNI aIINa Safety Instructions Care and Cleaning 2 S S 3 S S amp rvice Customer Se Installing the dryer Exhaust Ducting Length The exhaust system should be inspected and cleaned at least once a year with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation If roof vents or louvered plenums are used they must be equivalent to a 4 dampered wall cap in regard to resistance to airflow prevention of back drafts and maintenance required to prevent clogging MAXIMUM LENGTH of 4 10 2 cm Dia RIGID METAL DUCT DO NOTassemble the duct work with fasteners that extend into the duct They will serve as collection points for lint e Ductwork which runs through an unheated area or is near an air conditioning duct should be insulated to reduce condensation and lint build up MAXIMUM LENGTH of 4 10 2 cm Dia FLEXIBLE METAL DUCT PREFERRED VENT HOOD TYPE PREFERRED VENT HOOD TYPE 4 10 2 cm Louvered Number of 90 turns a 1102 e
29. um has completely stopped E Clean the lint filter before each load to prevent lint accumulation inside the dryer or in the room DO NOT OPERATE THE DRYER WITHOUT THE LINT FILTER IN PLACE E Do not wash or dry articles that have been cleaned in washed in soaked in or spotted with combustible or explosive substances such as wax oil paint gasoline degreasers dry cleaning solvents kerosene etc which may ignite or explode Do not add these substances to the wash water Do not use or place these substances around your washer or dryer during operation E Any article on which you have used a cleaning solvent or that contains flammable materials such as cleaning cloths mops towels used in beauty salons restaurants or barber shops etc must not be placed in or near the dryer until solvents or flammable materials have been removed There are many highly flammable items used in homes such as acetone denatured alcohol gasoline kerosene some household cleaners some spot removers turpentines waxes wax removers and products containing petroleum distillates E The laundry process can reduce the flame retardancy of fabrics To avoid such a result carefully follow the garment manufacturer s care instructions E Do not dry articles containing rubber plastic or similar materials such as padded bras tennis shoes galoshes bath mats rugs bibs baby pants plastic bags pillows etc that may melt or burn Some rubber
30. with a mirror that the inside flaps of the hood move freely when operating Make sure that there is no wildlife birds insects etc nesting inside the duct or hood Have a qualified technician vacuum the lint from the dryer once a year Care and Cleaning 4 foe Y S S S z Ss amp rvice Customer Se Preparing to install your dryer N Read these instructions completely and carefully E 77 E This dryer must be exhausted to the outdoors 45 7 cm off the ground and protected from lt using only rigid metal or flexible metal 4 vehicles by a barrier See Location of Your Dryer S diameter ductwork for inside the dryer cabinet section or exhausting E The electrical service to the dryer must conform 5 E Never use plastic or other combustible ductwork with local codes and ordinances and the latest See Exhausting section edition of the National Electrical Code E This appliance must be properly grounded ANSI NFPA 70 and installed as described in these Installation E The gas service to the dryer must conform Instructions with local codes and ordinances or the latest E Do not install or store appliance in an area where edition of the National Fuel Gas Code ANSI it will be exposed to water weather See Location 2223 1 The gas dryer is designed for use under 5 of Your Dryer section ANSI Z 21 5 1 This dryer is not recommended RY E The National Fuel Gas code restricts installat
31. ws that secure the door hinges to the dryer front panel NOTE Remove 1 screw from each of the 2 hinges first Hold the door firmly before removing the last 2 screws Rotate the door 180 and reinstall the door hinges to the dryer front panel with the 4 screws Remove 4 screws one from each hinge first Install the 4 hinge hole plugs or screws that were removed in step 1 into the open screw holes on the right side of the door opening Care and Cleaning ie S S S 2 S o 3 amp rvice Customer Se 16 Countdown Display DCD models only suon nysuj Ajajes The countdown display shows the remaining 45 minute timer cam pre installed in the coin box operating time as well as the current drying cycle If the timer cam is modified for another operating The display board is configured for a 45 minute duration the dip switches on the display board dry time at the factory to correspond with the should be set as follows ON O 1 2 J9 pue aie Guiuea NOTE This display does not accumulate time See the following examples of display possibilities DIP SWITCH SETTING min COIN SLIDE ACTUATIONS DISPLAY READING min 45 to 1 then 1 for next 45 min then 0 and blank 99 for 21 minutes then 98 to 0 then blank A q i 3 a A S Q S 77 J WOJSNI aIINa 17 GE Commercial Dryer Warranty 2 S S Pa
32. yer Mi This dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not modify plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Flectrical Installation for Electric Dryers A WARNIN G The following are specific requirements for proper and safe electrical installation of your dryer Failure to follow these instructions can create electrical shock and or a fire hazard A WARNIN G This appliance MUST be properly grounded Electrical shock can result if the dryer is not properly grounded Follow the instructions in this manual for proper grounding A WARNIN G DO NOT use an extension cord with this dryer Some extension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt creating electrical shock and or fire hazard Locate the dryer within reach of the wall outlet taking into account the length of power cord to be purchased and allowing some slack in the cord Refer to Electrical Requirements in this manual for the proper power cord to be purchased A WARNING A Usisted strain relief must be installed onto power cord If the strain relief is not attached the cord can be pulled out of the dryer and can be cut by any movement of the cord resulting in electrical shock A WA