Home
GE ZV750SY Kitchen Hood
Contents
1. TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Design Information Models available ceneri ess onines Optional Accessories ir Product Dimensions amp Clearances Advance Planning sisisi reigns pusisin ElectricalSupply ic ia ie Installation Preparation DUCE Fittings iii Tools and Materials Required Step 1 Remove the packaging Installation Step 2 Check Installation Hardware Step 3 Mount Template eee eeeees Step 4 Install Mounting Bracket Step 5 Install the Hood n Step 6 Install Duct Bracket eee eees Step 7 Connect Ductwork i Step 8 Connect Electrical eeeeee eee eeee Step 9 Install Decorative Duct Cover Step 10 Install Filters cee ceseeseecneeeees Step 11 Finalize Installation eee eee eee OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any ques tions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally If the service panel cannot be locked fasten a tag or prominent warning label to the panel For general ventilating use only Do not us
2. I Dimensions insure that the duct cover meets the ceiling The cooking E Clearances surface should be at least 36 above the floor Installation will be easier if the vent hood is installed before the Height range or cooktop and countertop is installed to Ceiling I 8 1 4 gt gt 34 5 8 21 5 8 A ac 26 1 4 for 8 ft ceiling y 38 1 4 for 9 ft ceiling 25 1 2 Recommended 38 1 4 to 50 1 4 for 9 ft to 10 ft ceiling using optional accessory ZX10SY Duct Cover 36 Min The distance between the cooking surface and the bottom of the hood must be at least 24 and up to 30 The 25 1 2 recommended installation height above the standard 36 countertop will insure duct cover fit to the ceiling Design Information 36 Vent Hood Advance Ductwork e Determine the exact location of the vent hood e Plan the route for venting exhaust to the outdoors e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 100 feet equivalent length for any duct configurations e Refer to Duct Fittings chart to compute the maximum permissable length for duct runs to the outdoors e Install a wall cap with damper or roof cap at the exterior opening Planning Electrical AWARNING e Connect the wiring to the house wiring in Warning for Supply ai accordance with local codes ill n Grounding Instruction Cio emove house The grounding
3. conductor must be connected to a ground metal permanent wiring system or an equipment grounding terminal or lead on the hood fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances WARNING Warning The improper connec Vili tion of the equipment ground ing conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded Electrical supply This vent hood must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse e Wiring must be 2 wire with ground e If the electrical supply does not meet the above requirements call a licensed electrician before proceeding e Route wiring as close to the installation location as possible in the ceiling or soffit Installation Preparation 36 Vent Hood Duct Use this chart to Total compute maximum Equivalent Quantity Equivalent fittings permissable lengths Duct Piece Dimensions Length Used Length for duct runs to Round 1 ft These Hoods Must outdoors T straight per foot Use 6 Round Duct length It Can Transition To Note Do not exc
4. y arate Wall Mount Template Tae Centerline To Wall lt 5 6 1 2 Dia Hole 4 Centerline PETE Min Above FOR WALL VENT DUCT Bracket Location 4 4 WALL DUCTING If ductwork will vent to the rear e Use the level to draw a line straight up from the centerline on the template e Measure at least 6 above the bracket location shown on the template to the centerline of the 6 1 2 dia duct hole Hole may need to be elongated for duct elbow HOUSE WIRING LOCATION e The junction box is located on the top of the hood at the front right side e Route house wiring as close to the installation location as possible through the ceiling soffit or back wall Wiring should enter at least 4 above the bracket on the right side Step Install Mounting Brackets Step Install the Hood Whenever possible the vent hood should be secured to wall studs e With the template taped in place use a punch to mark all mounting screw locations e Drill 1 8 pilot holes at the 6 punched locations e Remove the template e Enlarge holes that did not enter studs to 3 8 and tap anchors for wall fasteners into the holes Drive screws into the fasteners to allow anchors to expand against the wall material Remove the screws for final installation e Secure the mounting brackets to the wall studs with wood screws provided For hollow walls secure th
5. GE Monogram Installation Instructions 36 Vent Hood Model ZV750 Contents Before you begin Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES NOTE TO INSTALLER Be sure to leave these instructions with the Consumer NOTE TO CONSUMER Keep these instructions with your Use and Care Book for future reference This appliance must be properly grounded See Electrical Supply page 4 If you have questions concerning the installa tion of this product call the GE Answer Center Consumer Information Service at 800 626 2000 24 hours a day 7 days a week If you received a damaged vent hood you should contact your dealer CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION WARNING To reduce the risk of fire or electric shock do not use this range hood with any external solid state speed control device Any such alteration from original factory wiring could result in damage to the unit and or create an electrical safety hazard To reduce the risk of fire and to properly exhaust air be sure to duct air outdoors Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK
6. all the side utility bars as shown with screws provided 36 Vent Hood FT Duct Tape Over Seam and Screw pe Screw Air Flow e Insert house wiring through strain relief and tighten Connect white leads to branch circuit white lead e Connect black leads to branch circuit black lead e Connect green yellow leads to branch circuit green or bare ground lead e Secure all connections with wire nuts on each electrical connector e Push wires into junction box and replace cover Be sure wires are not pinched Install Optional ZX10SY Duct Cover e Separate the supplied duct cover into pieces Discard the upper or inner section e Insert the new ZX10SY duct cover into the original lower section Be sure that the new longer section is inside the shorter original section The notches will be at the bottom and the screw holes at the top as illustrated e Follow the same procedures shown above to install the new duct cover Step Install Filters 11 Finalize Installation Installation 36 Vent Hood e Remove protective film on filters eTo remove the filters grasp the knob and e Tip the filter into the lower slots at the rear push the filter towards the rear and tilt of the opening lift the filter and pull the downwards knob forward until the filter rests on the slots e Remove protective film covering the control pa
7. ceiling e Use a level to check that duct is vertical and GO TO STEP 6A duct bracket is centered IF YOU ARE e Mark the 4 screw locations of the bracket VENTING TO e Remove the bracket and temporary duct THE REAR ti section e Drill 1 8 pilot holes in marked bracket location e If pilot holes do not enter studs enlarge the holes 3 8 and install wall fastener anchors Drive screws into the fasteners to allow anchors to expand against the wall material Remove the screws e Secure the bracket to the ceiling and wall with wood screws and or wall fastener screws 8 Step The upper duct bracket should be installed against the ceiling This bracket will hold the A decorative duct cover in place at the top e Install the 2 small screws into the sides of the Install Duct duct bracket Remove the screws This will Bracket insure ease of final installation e Position the bracket against the wall and Pr ER ceiling Center the bracket using marked centerline of the hood SKIP THIS e Use a pencil to mark the bracket location STEP IF along its outside edges YOU ARE e Temporarily place the decorative duct cover VENTING on top of the hood and extend the inner VERTICALLY portion to meet the ceiling Straight Up e The duct cover should be level and align with marks for bracket e Remove the duct cover e Place bracket against marked location and mark the 4 screw locations e Drill 1 8 pilot h
8. e to exhaust hazardous or explosive materials and vapors Installation work and electrical wiring must be done by qualified person s In accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrig eration and Air Conditioning Engineers ASHRAE and the local code authorities Design Information 36 Vent Hood Model Model This vent hood is designed to be used in ZV750 vented installations Available A decorative duct cover is provided to cover the duct from the top of the hood to an 8 ft or 9 ft ceiling Optional Mode ZX10SY Accessories An optional stainless steel duct cover is available for 9 ft to 10 ft ceiling installations The supplied duct cover is sized to reach 8 ft to 9 ft ceilings Order the optional duct cover at the same time as the vent hood and have on site before installation Product The vent hood must be installed 24 min and 30 max an above the cooking surface 25 1 2 is recommended to
9. e mounting brackets through the anchors Place the hood on the brackets and slide left to right to align with rectangular slots at the top e Adjust the installation height by tightening or loosening the screws A at the bottom of the brackets e Align the hood lower mounting holes with pilot holes in the wall e Using two large flat washers supplied install wood screws or wall fastener screws loosely into lower mounting holes Do not tighten e Level the hood by tightening or loosening the screws A located on the bottom mount ing brackets e Tighten the lower mounting screws e Tighten screws B located at the top of the mounting bracket against the hood to clamp the position Do not overtighten screws Installation 36 Vent Hood Screws Note Screws A and B are pre assembled onto the brackets Do not remove these screws Screws B To Secure Hood To Wall Level and Height Adjustment Screws A Lower Mounting Screws Installation 36 Vent Hood Step e Install the 2 small screws into the sides of the duct bracket Remove the screws This will fa insure ease of final installation e Temporarily install a piece of 6 duct cut to Install Duct length between the hood outlet and the we ductwork at the ceiling Bracket e Position the upper duct bracket behind the ne for vertical exhaust duct and against the wall and
10. eed maximum n _3 14 x10 1 ft 3 1 4 x10 Or permissable equivalent lengths straight per foot n m N length 3 1 4 x12 Duct Maximum duct length guy 100 foot for range hoods OD 90 elbow 15 ft Flexible ducting If flexible metal o ducting is used all 4P elbow af the equivalent feet values in the table i CADI should be doubled dini ia The flexible metal duct should be de x10 straight and smooth anew ue and extended as a a much as possible i SZ 90 flat elbow 20 ft Do NOT use flexible plastic ducting Q oeroud te 3 1 4 x 10 or We 31 4 x24 transition 1 ft Note Any home ventilation 3 1 4 x 10 system such as a ventilation Q to 6 round transition 5 ft hood may interrupt the proper BN flow of combustion air and exhaust required by fireplaces al 6 round to gas furnaces gas water heaters 3 1 4 x 10 and other naturally vented w transition 90 elbow 5 ft systems To minimize the chance 3 1 4 x 10 to 6 round of interruption of such naturally Gi transition 90 bow 15 ft vented systems follow the heating da equipment manufacturer s guidelines and safety standards Round such as those published by NFPA ie wall cap and ASHRAE with damper 30 ft 3 1 4 x 10 wall cap CS with damper 30 ft Round roof cap 26 ft lt S gt Round roof vent 24 ft Actual length of straight duct plus duct fitting Total Duct Run equivalent Equivalent length of duct pieces are based on actual tests conducted by GE Evaluati
11. nel on the front face of the hood and any remaining packaging materials e Refer to the Use and Care book for operating instructions ll Monogram General Electric Company Louisville KY 40225 Note While performing installations described in this book safety glasses or goggles should be worn To obtain specific information concerning any Monogram product or service call GE Answer Center consumer information service at 800 626 2000 any time day or night For Monogram local service in your area call PONE ASTD Pub No 49 8990 1 NOTE Product improvement is a continuing endeavor at General Dwg No 164D3333P214 Electric Therefore materials appearance and specifications are 2000 GE Appliances subject to change without notice N D 612 5 00 Printed in Italy
12. oles in marked location e If pilot holes do not enter studs enlarge the holes 3 8 and install wall fastener anchors Drive screws into the fasteners to allow anchors to expand against the wall material Remove the screws e Secure the bracket to the ceiling and wall with wood screws and or wall fastener 8 Screws Step Connect Ductwork Step Connect Electrical Step Install Decorative Duct Cover and Utility Bars 10 Installation A NTa vg DO not use sheet metal screws at hood flange connection Doing so will prevent proper damper operation Seal connection with tape only e Install ductwork making connections in direction of airflow as illustrated e Secure joints in ductwork with sheetmetal screws e Wrap all duct joints with duct tape for airtight seal Verify that power is turned off at the source A WARNING ae e If house wiring is not 2 wire with a Vili ground wire a ground must be Gp provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and alumi num to copper connectors Mounting Screws Bottom Notches Place the decorative duct cover on top of the hood e Insert the lower portion of the duct cover into the impression on the top of the hood e Extend the inner duct upwards to meet the ceiling and bracket e Secure the duct cover to the bracket with the 2 small Phillips screws provided e Inst
13. on Engineer ing and reflect requirements for good venting performance with any ventilation hood Installation Preparation 36 Vent Hood Tools amp e Tape measure e Safety glasses e Knife e Tape to mount template Materials e Spirit level e Gloves to protect against sharp edges Required e Wire cutter e 120V 60Hz 15 or 20 Amp 2 wire with e Wire stripper ground Properly grounded branch circuit Gore e Wire nuts e Strain relief for junction box e Electric drill and appropriate bits 6 round metal duct work e Phillips screwdriver e Flat blade screwdriver e Hammer e Pliers The vent hood is shipped secured to a shipping board with 4 screws Step e Remove the duct cover parts box and styro foam packaging Remove the e Lift the hood out of the box using hand grips on both sides of the shipping board P ackaging e Remove and properly discard the plastic wrapping e Locate and remove 2 screws at the top of the assembly and 2 screws inside the hood behind the filter guides on the left and right sides Discard the shipping board e Remove junction box cover e Remove knockout from junction box e Install strain relief onto junction box Junction Mounting 07 l Shipping Board ing Screw Shipping Board Step Check Installation Hardware Step Ductwork Wiring Hood Attachmen
14. t Locations Locate the hardware accessory box packed with range hood and check contents 10 Wall Fasteners 2 Mounting Brackets Duct Cover Bracket i 2 Phillips Head Screws a a a Utility Bars with Screws To determine ductwork locations e Locate the template packed with the litera ture e Determine the exact installation location Measure 36 from the floor to the top of the cooking surface Add 25 1 2 recom mended space from the cooking surface to bottom of hood Mark that location Use a level to draw a straight pencil line on the wall Tape the template in position along the penciled line CHECK TO BE SURE TEMPLATE IS LEVEL e Measure from the peak of the hood to the ceiling as indicated The dimension should be 26 1 4 to 38 1 4 for 8 ft to 9 ft ceilings 38 1 4 to 50 1 4 for 9 ft to 10 ft ceilings this installation requires ZX10SY accessory duct cover CEILING DUCTING If ductwork will vent straight up to the ceiling e Use a level to draw a line straight up from the centerline on the template to the ceiling e Measure 3 1 2 from the back wall to the centerline of a 6 1 2 dia hole on the ceiling Note lf drywall is not present add drywall thickness to the 3 1 2 dimension Installation 36 Vent Hood 2 Large Flat Washers 10 Wood Screws Decorative Duct Cover mes f rot t pid f TR eS 1 eS
Download Pdf Manuals