Home

Dacor Millennia ETT365 Electric Cooktop

image

Contents

1. gacor Glass Top and Frame Foam Tape Seal Hold Down Bracket and Screw Countertop 4 102mm Cooktop Installation Section View Electrical Connection WARNINGS 1 Ensure that the power supply is disconnected before proceeding 2 Verify that the power supply matches the ratings found on the appliance data plate before proceeding 3 The complete appliance must be properly grounded at all times when electrical power is applied 4 Do not ground the appliance with the neutral white house supply wire A separate ground wire must be utilized 5 If aluminum house supply wiring is utilized splice the appliance copper wires to the aluminum house wiring using special connectors designed and agency certified for joining copper and aluminum 6 Follow the connector manufacturer s recommended procedure carefully Improper connection can result in a fire hazard These products are provided with a flexible conduit consisting of two 2 insulated hot lead conductors both copper and one 1 insulated ground conductor copper For UL installations attach the conductors to the residence wiring in accordance with National Electric Codes and all state municipal and local codes Verifying Proper Operation WARNINGS 1 Never touch any heating elements when the power is on 2 Ifthe cooktop glass is broken turn off power to the unit Do not operate until glass has been replace
2. d by a qualified service technician 3 This product must be repaired only by a qualified service technician Unit must be disconnected from power prior to service NOTES Before operating the unit 1 Clean the glass surface carefully using the Cooktop Cleaning Creme provided with the product Remove all cleaner residue 2 Read and understand the accompanying Use and Care Manual Important safety service and warranty information is contained within the manual If all final electrical connections are complete as indicated then proceed to turn on the power Once the power is on test each burner position for correct operation Any problems should be reported immediately to your installer or an authorized Dacor servicer NOTES dacor 4 NOTES 5 dacor NOTES dacor 6 Specifications contained within are subject to change without notice No liabilty is assumed by DACOR for changes in specifications Web Site www dacor com U For a Dealer Service 800 772 7778 L Corporate Phone 800 793 0093
3. dacor oa Installation Instructions Millennia Cooktops SAVE AND READ THESE INSTRUCTIONS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21 1 STANDARD FOR HOUSEHOLD GAS COOKING APPLIANCES CONVENTIONS USED IN THESE INSTRUCTIONS WARNINGS Must be followed carefully to avoid personal injury or damage NOTES Contain helpful hints and tips to facilitate the installation IMPORTANT Before beginning installation please thoroughly read and become familiar with these instructions Installation and service must be completed by a qualified installer or service agency Installer Please leave these Installation Instructions with the owner Owner Please keep these instructions for local electrical inspector s use and for future reference Read the accompanying Use amp Care Manual prior to operating this appliance Pe NS TABLE OF CONTENTS STEP 1 Verifying the package contents Page 2 STEP 2 Power disconnection Page 2 STEP 3 Electrical power supply requirements Page 2 STEP 4 Countertop preparation Page 2 STEP 5 Below countertop preparation Page 3 STEP 6 Installing the cooktop Page 3 STEP 7 Electrical connection Page 3 STEP 8 Verifying cooktop operation Page 3 Part No 65170 Rev D IMPORTANT SAFETY INSTRUCTIONS WARNINGS To reduce the risk of burns electric shock fire or injury to persons 1 Read all instructions before using the appliance 2 This appliance must be grounded Connect only to a p
4. elow the cooktop 2 Access to the underside of the cooktop and the junction box must be provided for inspection and service All models are designed for standard 24 inch deep 610mm base cabinets with 25 inch 635mm overall depth countertops Before making the countertop cutout make certain that the cooktop will clear the front and side walls of the base cabinet as shown Clearance is required for proper fastening of the cooktop hold down brackets Also allow a minmimum 2 inch 51mm clearance between the bottom of the cooktop chassis and any combustible surface including the upper edge of a drawer installed below the cooktop Locate the junction box within reach of the included 48 inch long 1219mm cooktop power lead such that the junction box is accessible when the cooktop is in place Installing the Cooktop WARNING Do not use a hardening compound or caulking to permanently seal the cooktop into place as the unit must be readily removable for service If such a hardening compound is used removal of the unit will be at the customer s expense Attach the foam tape provided with the unit to the underside of the cooktop frame Place and center the cooktop within the cutout Secure the cooktop to the countertop utilizing the two 2 hold down brackets provided Slide the brackets into the slots located on the left and right sides of the chassis then tighten the screws to the underside of the countertop 3
5. ments 2 Allow a minimum 2 inch clearance between the bottom NOTES If cabinet storage space is to be provided directly above the cooktop the risk of personal injury may be reduced by installing a ventilating hood that projects horizontally a minimum of 5 inches beyond the face of the cabinets of the cooktop chassis and any combustible surface including the upper edge of a drawer installed below the cooktop Access to the underside of the cooktop and the junction box must be provided for inspection and service e 4 102mm Chassis height 21 533mm 2 51mm Min to combustibles below chassis x 6 152mm Min to combustible side wall above Vertical Combustible Surface 3 1 8 79mm the cooktop 28 1 2 724mm both sides Rear Wall 19 7 8 635mm 2 51mm Cutout Dimensions for the CER304 ETT304 and MET304 CER304 shown rs 548 4 102mm Chassis height 4 2 51mm Min to combustibles below chassis Vertical Combustible 6 152mm Min to combustible R side wall above 3 1 8 the cooktop 79mm SAA ETE both sides Rear Wall 25 635mm 51mm Cutout Dimensions for the CERB365 ETT365 ETT365S and METB365 ETT365 shown dacor Below Countertop Preparation WARNING Failure to provide proper clearances may result in a fire hazard NOTES 1 Plastic or other utensils with low melting temperatures should not be stored in drawers immediately b
6. nity of this or any other appliance Installation and service must be performed by a qualified installer service agency or the electric company Improper installation adjustment alteration or maintenance can cause personal injury or property damage Refer to these instructions and the accompanying Use and Care Manual For assistance or additional information consult a qualified installer service agency dealer or the electric company Do not obstruct the flow of air to the unit Keep the appliance area clear and free from combustible material Do not attempt to use this appliance in the event of a power failure This appliance is designed as a cooking appliance Never use it for warming or heating a room Verifying the Package Contents Please contact your dealer immediately if components are missing e Use and Care Manual e Mounting Brackets Cleaning Creme Glass Scraper e Foam Tape Power Disconnection WARNING Failure to disconnect power may result in electrical shock or fire hazard If the electric service provided does not meet the product specifications do not proceed with the installation Call the selling dealer or a licensed electrician Electrical Power Supply Requirements It is the owner s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician The electrical installation including minimum supply wire size and g
7. roperly grounded outlet 3 Install or locate this appliance only in accordance with these installation instructions 4 Use this appliance only for its intended use as described in this manual Do not use corrosive chemicals or vapors in this appliance This type of cooktop is specifically designed to heat and cook food and liquids it is not designed for industrial or laboratory use 5 As with any appliance close supervision is necessary when used by children 6 Do not operate this appliance if it has a damaged electrical conduit or wires if it is not working properly or if it has been damaged or dropped 8 This appliance should be serviced only by qualified service personnel Contact the nearest DACOR Authorized Servicer at 800 772 7778 or at www dacor com for examination repair or adjustment 9 Do not cover or block any openings on the appliance 10 Do not store or use this appliance outdoors Do not use this product near water for example near a kitchen sink in a wet basement or near a swimming pool etc 1 gacor 11 12 13 14 15 16 17 18 19 Some products such as closed glass jars may explode and should not be heated on this cooktop If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vici
8. rounding must be in accordance with the National Electric code ANSI NFPA 70 1993 or latest revision and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 The correct voltage frequency and amperage must be supplied to the appliance from a separate grounded circuit that is protected by a properly sized circuit breaker or time delay fuse Refer to the data plate located on the bottom of the chassis and or to Table 1 below for electrical supply requirements Countertop Preparation WARNINGS 1 To reduce the risk of personal injury caused by reaching over a hot appliance cabinet storage space located directly above the cooktop should be avoided 2 Do not store combustible materials or items adversely affected by heat in cabinet areas above the appliance 3 Failure to provide proper clearances may result in a fire hazard Total Connected Minimum Supply Wire Size Model No Electrical Circuit Required Load Line and Ground Connections 240VAC 60Hz 40A 6 9kW 29A CER304 208VAC 60Hz 40A 6 9kW 33A 240VAC 60Hz 50A 9 6kW 40A CERB365 208VAC 60Hz 50A 9 6kW 46A ETT304 240VAC 60Hz 30A 6 9kW 29A No 8 AWG ETT365 8 9kW 37A ETT365S 240VAC 60Hz 40A MET304 6 9kW 29A METB365 240VAC 60Hz 50A 9 6kW 40A Electrical Supply Requir