1. Drain cap Care and l Maintenance Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary To remove 1 Open the inlet grille downward by pulling out the top of the inlet grille 2 Remove the air filter from the front grille assembly by pulling the air filter up slightly 3 Clean the filter with warm soapy water below 40 C 104 F 4 Rinse and gently shake the water from the filter and let it dry before replacing it Z ll L CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance NOTE Before using the air conditioner secure the front grille with two screws enclosed with the owner s manual 1 Open the inlet grille downward and remove the air filter 2 Fasten the front grille with screws 3 Reinstall the air filter 4 Close the inlet grille Inlet Grille Hardware i Installation Hardware Installation Learning parts name prior to installation will help you understand the installation procedure Features CABINET a al SIDE LOUVER FRO
2. Bracket 11 l 8 hesiinche Put the Support Bracket against the outside wall and tighten the Bolts on top of the Bracket Adjust the Leveling Bolt so that the air conditioner will be installed with a very slight tilt about 1 4 downward toward the outside for proper drainage Tighten the nut Fig 3 NOTE DO NOT drill a hole in the bottom of the base pan The air conditioner is designed to operate with the bottom of the base pan approximately half full of water Horizontal Sliding Window Ins 5 Fasten Side Guides to the sides of the Air Conditioner using 3 Type A screws per Guide Start with first screw at middle of Guide Fig 4 Fasten Upper Guide on the top of the Air Conditioner using 3 Type A screws Fig 4 Fastening Side Guides op Side Guide N Measure height of window opening from top of Bracket assembly as shown Fig 5 Subtract 20 3 4 inches Mark this measurement on Curtain and cut the Curtain Fig 5 8 Slide Curtain into Curtain Frame Slide Curtain Frame assembly into side Guides of the Air Conditioner cabinet Make sure Curtain is firmly enclosed on all sides by the Frame Curtain Frame Fig 6 Curtain 9 Cut side Guide seal into 2 equal lengths Remove protective backing and apply it to the rear side of cabinet Side Guides starting just below Curtain Frame assembly Pinch off excess length so seal is even with the botto
3. f G website http www lg ca LG Window Type Air Conditioner OWNER S MANUAL 1 MODELS LEAO610ACL LEAO810ACL LEA1010ACL LEA1210ACL IMPORTANT Please read through this manual It contains valuable information about your air conditioner This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use PRECAUTIONS Pay close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation LG is not responsible for any damages caused by misuse of the air conditioner Window Type Air Conditioner Owner s Manual TABLE OF CONTENTS or Your Records Write the model and serial numbers here Model Serial You can find them on a label on the side of each unit Dealer s Name Date Purchased ead This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all N NY 5 AN CAUTION e Contact the authorized service technician for repair or maintenance of this unit e Contact the installer for installation of this unit e Th
4. furniture blocking the front of the air conditioner E 7he TEMP Control may not be set Turn the knob to a higher number high enough The highest setting provides maximum cooling E The air filter is dirty e Clean the filter at least every 2 weeks See the care and maintenance section Air conditioner Co ee does not coolas The room may have been hot e When the air conditioner is first turned on it should you need to allow time for the room to cool down E Cold air is escaping e Check for open furnace floor registers and cold air returns e Set the air conditioner s vent to the closed position E Cooling coils have iced up e See Air Conditioner Freezing Up below Air conditioner M ce blocks the air flow and stops the freezing up air conditioner from cooling the room e Set the mode control at High Cool with the high temperature mark 1 or 2
5. 1 4 This will force condensed water to flow to the outside 5 Install the unit with the bottom about 30 60 above the floor level Window Requirements 1 These instructions are for a horizontal sliding or a For installation in a casement window the window casement window frame assembly and the side of the building must be 2 The electrical outlet must be within reach of the adequate to support the weight of the air conditioner power cord 21 min 40 2 max 21 14 min 15 1 4 min 16 2 max Horizontal sliding window Casement window Installation Kits Contents i Horizontal Sliding Window nut Fig 1 2 Remove protective backing from Window Track Seal and apply seal to window track Fig 2 3 Measure and lightly mark a line 8 1 4 inches from window jamb Center the Support Bracket assembly on the window track and fasten with 4 Type C screws Fig 2 Loosely attach the Support Bracket to the bottom of Bracket using Bolts Washer and Nuts Attach the Leveling bolt and Q TY Curtain Curtain Frame Upper Guide Side Guide Support Bracket Bracket Leveling bolt amp nut Bolt NO 1 3 4 5 6 7 8 9 Nut Washer 1 0 1 Side Guide seal 3 12 Foam Seal Strip 1 Window Track Seal 14 Window Locking Bracket 15 Screw Type A 16 Screw Type B 17 Screw Type C
6. NT GRILLE Zz LD AIR FILTER VERTICAL AIR DEFLECTOR x j HORIZONTAL LOUVER AIR INTAKE AZ INLET GRILLE J FF 7 s ASS Sx POWER CORD Installing the Power cord f You can choose between the two methods below according to your preference and window sill shape Oooo Ge E Using slit B e Fasten the stopper using Type A screw and lead e Fasten the stopper using left screw hole and rotate out the power cord aut through slit A properly to lead the power cord out through slit B Screw Type A Screw Type a iy Power cord Power a Hardware Installation INSTALLATION How to Install the Unit F 1 To prevent vibration and noise make sure the unit is installed securely and firmly 2 Install the unit where the sunlight does not shine directly on the unit Fence Cooled air 3 The outside of the cabinet must extend outward for at Heat least 14 and there should be no obstacles such as a n Pa TANO fence or wall within 20 from the back of the cabinet gt because it will prevent heat radiation of the condenser a sral Restriction of outside air will greatly reduce the cooling gt at 1 4 efficiency of the air conditioner y Over 20 fap CAUTION All side louvers of the cabinet must remain exposed to the outside of the structure xz 4 Install the unit a little slanted so the back is slightly lower than the front about
7. OOL LOW COOL setting setting 2 Set the TEMP control to the desired temperature 2 Set the TEMP control to the highest 9 mark 5 the mid point is a good starting position temperature mark If the room temperature is not satisfactory after a reasonable time adjust the control to a cooler or warmer setting as appropriate e FOR QUIETER OPERATION 1 Turn the MODE Knob to the LOW COOL setting 2 Set the TEMP control as needed Additional controls and important information Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions When fresh air is necessary in the room set the ventilation lever to the OPEN position The damper is opened and room air is drawn out Air Direction The direction of air can be controlled wherever you want to cool by adjusting the horizontal louver and the vertical louver e HORIZONTAL AIR DIRECTION CONTROL The horizontal air direction is adjusted by rotating the vertical louver right or left e VERTICAL AIR DIRECTION CONTROL The vertical air direction is adjusted by rotating the horizontal louver forward or backward How to Secure the Drain Pipe In humid weather excess water may cause the BASE PAN to overflow and be splashed on the SIDE LOUVER To drain the water remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN Drain pipe c CLOSE siis VENT alla OPEN
8. discourage the use of an extension cord However if you wish to use an extension cord use a CSA certified UL listed 3 wire grounding extension cord rated 15A 125V Common Issues Before you call for service Troubleshooting Tips Save time and money Review the chart below first and you may not need to call for service Normal Operation e You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency e You may hear the thermostat click when the compressor cycles on and off e Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outdoor side of the unit The fan may run even when the compressor does not Abnormal Operation Problem Possible Causes What To Do E he air conditioner is unplugged Make sure the air conditioner plug is pushed completely into the outlet Air conditioner E he fuse is blown circuit breaker is Check the house fuse circuit breaker box and doesnorsta tripped replace the fuse or reset the breaker E Power failure e If power failure occurs turn the mode control to Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload E Airflow is restricted e Make sure there are no curtains blinds or
9. e air conditioner is not intended for use by young children or invalids without supervision e Young children should be supervised to ensure that they do not play with the air conditioner Safety Precautions Precautions To prevent injury and property damage follow these instructions Incorrect operation due to ignoring instructions will cause harm or damage the seriousness of which is indicated by the following symbols A WARNING this symbol shows the possibility of death or serious injury A CAUTION Tris symbol indicates the possibility of injury or damage to property OQ Never Do This O Always Do This E The following items are classified by these symbols N WARNING Plugtin the power plug Do Not operater stop the WO Do not damage or use an properly unit by inserting or pulling unspecified power cord out the power plug e Otherwise it will cause electric e It will cause electric shock or fire e It will cause electric shock or fire shock or fire due to heat due to heat generation e If the supply cord is damaged it must be generation or electric shock replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Y attachment QDonot modify power cord Do not operate with wet Always plug into a length or share the outlet h nds orindamp grounded outlet with other appliances environment e It will cause electric shock or fire e It will cau
10. ecial purpose Such as animals or vegetables precision machine or conservation of art articles Donat put a pet of house plant where it will be exposed to direct air flow When cleaning the unit first make sure_the power and breaker are turned off e Since the fan rotates at high e This could injure the pet or plant It may cause damage of animals speed during operation it may or vegetables or loss of property Cause injury Holathe plug by the head Atitroff the mainpower when taking it out switch when not using it for along time StoOpoperation instorm or hurricanes e Operation with windows opened It may cause electric shock and __ It may cause failure of product or may cause wetting of indoor and damage fire soaking of household furniture Always insert the filters securely Clean it every two Enstirethat an installation console of the outdoor appliance is not damaged Dootplace obstacles around the absorption inlet Onoutput dueto the use for atong time Weeks e It may cause failure of appliance e If leaving appliance damaged e Operation without filters will or accident there is concern of damage due cause failure to the falling of product amp Dootuse strongdetergent W Dootplace heavy object on the such as wax or thinner but power cord and take care so that use a s ftcloth the cord should not be pressed OP eles ace Melanhaeliaelecliarve from air conditio
11. g 10 DO NOT CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER PLUG A SITUATIONS WHERE THE APPLIANCE WILL BE DISCONNECTED ONLY OCCASIONALLY TEMPORARY METHOD Adapter plug Metal screw Because of potential safety hazards we strongly discourage the use of an adapter plug However if you wish to use an adapter a TEMPORARY CONNECTION may be made Use UL listed adapter available from most local hardware store Fig 11 The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection CAUTION Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded Disconnect the power cord from the adapter using one hand on each Otherwise the adapter ground terminal might break DO NOT USE the appliance with a broken adapter plug B SITUATIONS WHERE THE APPLIANCE WILL BE DISCONNECTED OFTEN Do not use an adapter plug in these situations Unplugging the power cord frequently can lead to an eventual breakage of the ground terminal The wall power outlet should be replaced by a three slot grounding outlet instead USE OF EXTENSION CORDS Because of potential safety hazards we strongly
12. juries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and breaker are turned off The fan rotates at a very high speed during operation There is a possibility of injury if the unit s power is accidentally triggered on while cleaning inner parts of the unit Service For repair and maintenance contact your authorized service dealer Operating l E Instructions About the Controls on the Air Conditioner Controls e CAUTION When the air conditioner has been performing its cooling operation and is turned off or set to the fan position wait at least 3 minutes before resetting to the cooling operation again Function Turns air conditioner off Med speed fan operation without cooling Low speed fan operation without cooling Cooling with high speed fan operation D Cooling with med speed fan operation Cooling with low speed fan operation This automatically controls the temperature of the indoor air Turn the knob so that arrow point to the higher number for greater cooling Point the arrow to the lower number for more moderate cooling i e the higher number the greater cooling COOLEST e FOR NORMAL COOLING e FOR MAXIMUM COOLING 1 Turn the MODE Knob to the HI COOL from the 1 Turn the MODE Knob to the HI C
13. ler panel Make this panel from 3 4 inch thick wood and run it the full length of the window Attach it securely to the window frame and paint it to protect it from the weather 3 Since styles and sizes of casement windows vary widely it is advisable to have the air conditioner installed by someone skilled in this type of installation Electrical Data y Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut or remove the Use 15 AMP time grounding prong delay fuse or circuit from the plug breaker Power supply cord with Standard 125V 3 wire grounding 3 prong grounding plug receptacle rated 15A 125V AC USE OF EXTENSION CORDS Because of potential safety hazards we strongly discourage the use of an extension cord However if you wish to use an extension cord use a CSA certified UL listed 3 wire grounding extension cord rated 15A 125V 13 Electrical Safety F IMPORTANT PLEASE READ CAREFULLY FOR THE USER S PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three prong grounding plug Use this with a standard three slot grounding wall power outlet Fig 10 to minimize the hazard of electric shock The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded PREFERRED METHOD D Ensure proper ground exists before use Fi
14. m of side Guide Fig 7 Apply weather seal to side guides just below edge of Curtain Frame Fig 7 10 Place Air Conditioner in window opening It should sit on Bracket assembly so that Curtain Frame and cabinet Side Guides are against top and side window jambs Mate front of Bracket with Base Guide attached to the bottom of base pan 11 Drill 1 8 inch holes in window track through the existing holes on Base Guide Screw 4 Type C screws through the holes Fig 8 12 If this is a casement window installation proceed to Casement Window Installation If not slide inner window Type C screw sash firmly against side of the cabinet Window Track 13 Drill 1 8 inch hole in window jamb to align with the existing holes in the Curtain Frame Attach Curtain Frame to window frame with 2 Type B screws Fig 8 NOTE Check all seals and plug any remaining air gaps with a suitable weatherproof caulk 14 If this is a casement window installation proceed to Casement Window Installation If not stuff the Foam Seal Strip between the vertical sash and the window glass Fig 9 15 Attach the L Bracket with a Type B screw Fig 9 Casement Window Installation 1 Installation procedure is the same as that described in steps 1 through 11 and step 13 of the Horizontal Sliding Window installation 2 If the window opening is wider than 15 3 4 inches you will need to install a fil
15. ner e Appearance may be deteriorated There is danger of fire or electric It contains containments and will due to change of product color or shock make you sick scratching of its surface Ifwater enters the product turn off the the O Bonot direct airflow at r m occupants only power switch ofthe main body of appliance Contact service center after taking the power plug out from the socket e This could damage your health Safety Precautions Preparing for operation 1 Contact an installation specialist for installation 2 Plug in the power plug properly 3 Do not share the same outlet with other appliances 4 Do not use an extension cord 5 Do not start stop operation by plugging unplugging the power cord 6 lf cord plug is damaged replace only with an authorized part Usage Being exposed to direct airflow for an extended period of time could be hazardous to your health Do not expose occupants pets or plants to direct airflow for extended periods of time 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Usage in such a manner could harm such property Cleaning and maintenance 1 Do not touch the metal parts of the unit when removing the filter In
16. se electric shock e No grounding may cause electric due to heat generation shock See Installation Manual Do not allow water to run Alw ys instalF ir l kage W Unplug the unit if str nge int lectric parts breaker and a dedicated s unds odors or smoke switching board comes from it e It will cause failure of machine or No installation may cause fire e It may cause fire and electric electric shock and electric shock accident shock accident Do not use thesocketif it is HC Do not open the entrance Keehp firearmsaway loose or damaged during operation e It may cause fire and electric e It may cause electric shock e It may cause fire shock Donot use the power cord close to the heatihg tools Denot use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc It may cause fire and electric shock e It may cause an explosion or fire Ventilate before operating air conditioner Donot disassemble or modify products when gas goes out randomly e It may cause explosion fire and burn JNe Verntouch the metal parts Hi Doenot clean the air N rtilate well when used of the unit when removing conditioner with water together with a stove etc the filter e They are sharp and may cause e Water may enter the unit and e An oxygen shortage may occur injury degrade the insulation It may cause an electric shock Doniotuse appliance for sp