Home
Sunpentown WA-1010E 10,000 BTU Portable Digital Air Conditioner with Remote
Contents
1. TROUBLESHOOTING YOUR GUARANTEE sissssessssssssssssssssccsvscsusssnsssscssosnvenroscavsosanesssosesussovssssssoseassasustavacreaveesevestoesetes 14 Troubleshooting The unit doesn t run or only runs in fan mode Is the machine plugged in Is the mains power supply on Is the room temperature in the working range Is the unit in cooling mode or heating mode rather than auto mode when it will work according to its own settings The unit seems to do little Is there direct sunshine Please close the curtains or blinds Are too many windows or doors open Are there too many people in the room Is there something in the room producing lots of heat The unit seems to do nothing Is the dust filter dirty Is the air intake or outlet blocked up Is the room temperature within the selected temperature 5 F The room is not cold enough The room being cooled should have proper insulation If the unit is used in UN INSULATED rooms such as Sunrooms Garages or Attics ideal cooling might not be attained Too noisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run The overheat protection feature on the compressor might be on If this occurs wait for the temperature of the unit to drop Is the water container full Does it need draining NEVER TRY TO REPAIR OR DISMANTLE THE UNIT YOURSELF
2. from the mains before beginning the cleaning Cleaning the Housing Use a soft damp cloth to wipe the body clean Never use strong chemicals oil based products detergents chemically treated cloths or other cleaning solutions These could possibly damage the cabinet Cleaning the Filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse them thoroughly under running water no hotter than 104 F Dry thoroughly before replacing Do not wet the activated carbon filter remove from frame before rinsing Notice Never operate the unit without the filters End of Season Storage Unplug the unit Drain the condensed water COMPLETELY please refer to page 11 Clean or change the filter On a warm day turn the unit to fan mode for a couple of hours so that the inside can dry out completely It is recommended that the unit be put back into its original carton for storage Do not stack heavy objects on top of the unit Storing the Power Cord When the unit is not in use please store the power cord away as shown in Figure 3 Fig 3 Thank You Thank you for choosing the portable air conditioner from SUNPENTOWN a leading brand in indoor air treatment We would like you to enjoy the many benefits this unit offers so please take the time to read this manual carefully and take full advantage of the many advanced features that your SUNPENTOWN Air Conditioner offe
3. to the exhaust hose 13 Foam Strip for filling the open window space 14 Round Connector to be used between hose and window kit or between hose and wall 15 Cap for Round Connector 16 Remote Control Electronic control models only Operation Mechanical Models WA 1010M Power indicator Fan operating indicator Cooling operating indicator Full water indicator Thermostat Dua w y Speed switch with options for LOW FAN HIGH FAN LOW COOL HIGH COOL 7 Timer 1 8 hours as well as ON OFF switch 5 Turning ON OFF Set TIMER to ON for continuous operation the unit will operate as long as it is not turned off Power indicator comes on To turn off the unit turn the TIMER to the OFF position Setting Function Ventilation Speed High Cool s WA 1010M Turn the speed switch to select the required setting LOW FAN HIGH FAN LOW COOL HIGH COOL SPEED OFF Low Fan Low Coo yr High Fan Specifications Model Number WA I010E WA 1010M WA 1010H Cooling Capacity 10 000 BTU hr 10 000 BTU hr Heating Capacity 1 2 N A 10 000 BTU hr Power Consumption 660W 6 3A 660W 6 3A Humidity Removal Capacity 50 Pts day 50 Pts day Recommended Room Size 300 sq ft 300 sq ft Power Supply 120V 60Hz Phase 120V 60Hz Phase Compressor Rotary Rotary Refrigerant R 22 R 22 Fan Speed 2 2 Timer WA 1010E I 12
4. 3 minutes before switching it on again The cooling system will switch off if the room temperature is lower than set The fan however keeps working at the set level If the ambient temperature rises above the chosen temperature 5 F the cooling will resume In heating mode the compressor will switch off if the room temperature is HIGHER than e the set one still the fan keeps working at the set level As the room temperature drops below the selected level 5 the heating will resume This machine is equipped with an ANTI FROST function While using the heating function during low temperatures sometimes the heating will stop for a while in order to melt the internal frost When this occurs just wait for heating to resume e Make a hole 4 s in diameter in the wall to fit the supplied round connector As you switch on the heating the fan will stop for 15 20 seconds first for warm up purposes e Fit the hose directly to the round connector e When the hole is not in use use the cap for the round connector to cover the hole Installation Control Panel Mounting the exhaust pipe Automatic mode indicator A 2 Cooling mode indicator e The supplied exhaust hose can be ee Fan mode indicator 4 Heating mode indicator extended from l foot to 5 feet For WA 1010H for mounting It is recommended that aren 5 Compressor operation indicator you use the shortest possible length of hose i nen 6 Set
5. Sold through Sylvane LLC 800 934 9194 SUNPENTOWN Portable Air Conditioner Heater Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired or replaced free of charge This guarantee is subject to the following terms SUNPENTOWN must be notified of the fault Proof of purchase must be presented to SUNPENTOWN s nominated representative The warranty will be void if the product is modified misused or repaired by an unauthorized person The guarantee after repair or replacement will not be extended beyond the original one year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of SUNPENTOWN The warranty applies to the use of this product in the United States Warranty does not include freight charges Instruction Manual For models WA IOIOE WA IOIOH VWWA IOIOM PORTABLE Air Conditioner 7 ee ee oe ES A ay oe 2 es eww Ay rr a OA ee ee ee es ey n j y 7 It is important that you read y these instructions before using your new purchase and we strongly recommend that This GUARANTEE is in addition to your Statutory Rights oy you keep them in a safe place for future reference Dear Customer Please keep this warranty for your record DO NOT return it 14 Maintenance Always unplug the unit
6. b amp rubber plug from the drain hole The condensed water will drain out automatically Rubber Plug Draid Knob 4 When the container is almost full replace the rubber plug into the drain hole to stop the water Empty the container 5 Repeat steps 2 3 amp 4 until all the condensed water is emptied 6 Once all the condensed water has been removed q a oe replace the rubber plug into the drain hole firmly The Full Water indicator should be off now af 7 Replace the drain knob x By Water Tube Continuous Drainage Din rain Fipe Remove the drain knob and rubber plug and keep them j for future use q 2 Connect a suitable water tube of 3 4 internal diameter supplied to the water hole The condensed water will drain a out automatically 3 If you want to extend the water tube you can connect it with another tube outside diameter 3 4 Original Water Tube Special Caution for Heating Function 9 Extended Water Tube While using the heating function please note OD 3 4 Install the exhaust pipe securely in order to exhaust the cool air to the outside please see page 6 2 Use the continuous drainage option as described above 3 The warmer the outside air the more heat will be pumped into the room Working range for heat pump function is 41 F to 81 F When used in room temperatures outside this range the unit may not function properly 4 While using the heating function during low temperatu
7. barefoot Avoid all contact with chemical based materials The filter must be used with the product at all times When removing for cleaning always disconnect the unit from the mains first Turn off the appliance when not in use At the end of each season all water must be drained and the unit and filters cleaned before storage Drainage of the water container is required before moving the unit or putting it into storage If the electric socket is different from the plug provided have a professionally qualified electrician replace the plug with a suitable one Avoid the use of adaptor plugs multiple sockets and or extension leads if their use is necessary ensure that they conform to the current safety regulations Do not pull the supply cable or place it near a source of heat always unroll it completely to avoid the possibility of dangerous overheating If the supply cord is damaged it must be replaced by the service agent or a similarly qualified person THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED Setting The Fan Speed Press the SPEED button to choose the fan speed you require high or low The indicator of high or low fan will light up at the same time Mounting the unit This unit is a portable air conditioner It can be moved from room to room so that the cooling can follow you anywhere Fitting the exhaust hose is easy through a window or wall If the unit is
8. hours 1 12 hours WA 1010M I 8 hours Thermostat 64 F 90 F 64 F 90 F Net Weight 65 Ibs 68 lbs Dimensions I7 W x I7 D x 30 H 15 W x 16 D x 30 H Working Temperature Cooling 64 F to 110 F Cooling 64 F to 110 F Heating 41 F to 81 F REMARKS The data may vary please refer to the rating label on the back of the unit 2 The above conditions are measured at Cooling Indoor RT 81 F RH 60 Heating Indoor RT 68 F RH 60 Uninsulated rooms such as sunrooms garages or attics should be less than 300 sq ft Drainage During the process of cooling some water will be extracted from the air into the unit Most of this water is used to cool the unit and make it run more efficiently This is a feature not found in most Portable Air Conditioners If the unit is operated inVERY HUMID air water will collect in the container inside the unit If the water container is full the compressor will stop but the fan will continue to circulate the air The POWER indicator will blink to inform you to empty the internal container To make the cooling function work again please empty the water by one of the following methods By the Draining into a Container Use a Shallow Container or Dish Turn off the unit 2 Position a flat container or dish under the drain hole Do not allow the water to drip continuously into the container as it might easily overflow w Remove the drain kno
9. in AUTO mode it will select the fan speed automatically according to the Please refer to either of the following ways ambient temperature the related indicators cool fan or heat will light up at this time the fan speed switch is invalid Using the foam strips Setting the Timer Press the TIMER button to set the operating hours you desire 1 to 12 hours the timer indicator will light up When the set time has elapsed the machine will turn off automatically The display window will show the hour s you set as you press the TIMER button If the timer button is not pressed the unit will work continuously By pressing the timer button but without turning on the unit you can PRE SET the time for the machine to work For example if you press the timer to 2 the unit will come on automatically after 2 hours All the above functions can also be performed with the supplied remote control This remote control requires 2 AAA batteries to operate Connect the supplied foam strips with the exhaust pipe let the hot air flow to the outside Regulating the airflow direction Turn the roller on the air vent to control the airflow direction from the vertical louvres e Should the foam strip s be too large cut off the extra part to fit the window 2 Using the Through the Wall Connection Notice To prolong the unit s life it will start 3 minutes after the unit was switched on After switching off please wait at least
10. ller on the air vent to control the airflow direction from the vertical louvres NOTICE e The compressor will start approximately 3 minutes after the unit is turned on this will help prolong the life of the compressor After switching the unit off please wait at least 3 minutes before turning the unit back on The cooling system will switch off if the room temperature is lower than set The fan however keeps working at the set level If the ambient temperature rises above the chosen level the cooling will resume Important Transport the unit in an upright position only or leave it in an upright position for at least 2 hours before first use Always place the unit on an even surface Figure 1 Make sure the unit is connected to a correctly grounded power supply refer to the rating label located at the back of the unit An opening in a window or wall is required to accommodate the exhaust hose kit supplied to expel the warm air Do not cover or obstruct the appliance inlet or outlet grilles Figure 2 To avoid the risk of shock the product should never be used in bathrooms shower rooms or in any other steamy or wet areas The unit will cool when the room temperature is between 64 F and 110 F depending on the thermostat setting Do not sit or place objects on the unit Do not touch the unit with wet damp hands or when standing
11. mperature is lower than 68 F WA 1010H only Do not replace or extend it with your own hose j A If room temperature is between 68 F and 75 F unit will stay in Fan mode Again when in Auto Mode the temperature as this could cause the unit to malfunction SN 4 settings cannot be changed this product Setting the Temperature in Cooling or Heating Mode The display window s default is to display the ambient room temperature The green indicator light under RT is on 4 RT Room Temperature To set your desired temperature press the Temperature Up or Down buttons ranging from 64 F to 90 F Each press will increase or decrease your set temperature by 1 F When pressing the temperature up or down buttons the window will change to display your set temperature At this time the green indicator will light under ST Set Temperature Once the temperature up or down buttons is released the window will return to displaying the ambient temperature after a second Note When unit is in the following modes Auto Cool or Heat the compressor will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode To conserve energy the compressor will not start immediately after a couple degrees increase or decrease but will wait for a 5 F allowance For example In Cooling Mode with a set temperature of 70 F When compressor first stops af
12. res sometimes the heating will stop for awhile in order to melt the internal frost When this occurs just wait for heating to resume This is normal for compressor operated devices Table of Contents THANK YOU wil Energy Saving SPECIFICATIONS rere aAA OEA 2 BERORE USE s scssssssssssasssasssessssvasosesspusnsenosshedstetas aeaiaioe Enin 3 Accessories 4 INSTALLATION scsscsssssssssssssstaosscasssssssncssscaststssastssstnbsesoscecassoncessesdstnbsctassadsecentenibsesbsssbabsbevssevatentes 5 Mounting the Unit Mounting the Exhaust Pipe Installation of the Carbon Filte OPERATION ELECTRONIC CONTROL MODELS Control Panel Turning On Off Setting Mode Function Auto Modes Setting the Temperature Setting Fan Speed Setting the Timer Regulating Airflow Direction OPERATION MECHANICAL CONTROL MODELS c cscsssseessssesssseesseessseessseesseesssees 9 Turning OMO isss Setting Function Ventilation Speed Setting the Temperature 10 Setting the Timer Regulating the Airflow Direction DRAINAGE racssssssovssssusssesnsssaceatsssctuassnssgeatstadyastvhetaastek suastetuduscishedasetetatedsnensosssnsnaescenoagenicnetiensi By the Draining into a Container By Water Tube continuous drainage MAINTENANCE riran aE EEO ORE AORA 12 Cleaning the Housing Cleaning the Filter End of Season Storage Storing the Power Cord
13. rs you SUNPENTOWN has specialized in complete indoor environment control manufacturing world class air conditioners dehumidifiers and air purifiers with innovative technology In designing these advanced products we have listened carefully to our customers and have passed their views on to our research and development laboratories We wish you many years of enjoyable use After reading this manual please keep it in a safe place for future reference Energy Saving Tips Please use the unit in the recommended room size Refer to SPECIFICATIONS Do not locate the air conditioner where furniture or other objects can obstruct the airflow Keep blinds curtains closed during the sunniest part of the day Close the fireplace damper and floor or wall grills so that cool air does not escape through the chimney or ductwork Keep the filters clean Set the unit to maximum cooling and high speed fan initially then adjust the unit to a comfortable setting NOTE It is recommended to turn on the air conditioner when the room temperature is around 75 F Do not wait until the room is excessively hot Operation Mechanical Mode Setting the Temperature Turn the THERMOSTAT to regulate the temperature you desire range 64 F to 90 F Setting the Timer Set the TIMER to the desired operating time 1 to 8 hours When the set time has elapsed the machine will shut off automatically Regulating the Airflow Direction Turn the ro
14. temperature indicator ite 5 eRe 0e 7 Room temperature indicator Y 8 Timer operation indicator A y K N Take care to prevent any kink or 9 Low ventilation indicator W 2 oJ 4 bend in the middle of the exhaust 10 High ventilation indicator 13 Timer button 16 Temperature Up button hose as this will trap hot exhaust air 11 ON OFF power button 14 Receiver for Remote Control 17 Display window which will radiate back into the room 12 Speed ventilation button 15 Temperature Down button 18 Mode function option button Turning ON OFF Press the ON OFF selector the unit will start to work at its last setting Setting Mode Function Press the MODE button to select the required working mode Automatic Cooling Fan or Heating Heating is only available for WA 1010H The green indicator illustrating your selected mode lights up It is recommended to select Cooling or Heating mode and set your desired temperature as the Auto mode has a preset temperature please see below that cannot be changed WARNING The indicators of the functions in progress come on at the same time e g Cool and Lo Cooling mode with Low fan speed The length of the exhaust pipe is specially Auto Mode designed according to the specification of i When this mode is selected the unit is preset to the following temperature settings and unit will only start to Cool when room temperature is higher than 75 F Heat when room te
15. ter reaching 70 F unit will auto switch to Fan Compressor will start cooling again when ambient temperature increases to 75 F or above In Heating Mode with a set temperature of 72F When compressor first stops after reaching 72 F unit will auto switch to Fan Compressor will start heating again when ambient temperature drops to 67 F or below In Auto Mode with preset temperature of 68 F for heat and 75 F for cool Compressor will start cooling again when ambient temperature reaches above 80F or will start heating when ambient temperature drops below 63 F Installation of the Carbon Filter 1 Remove the filter frame from the unit 2 Separate the filter from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fixer onto the filter frame J Sf is LS sens 6 Re fit the filter frame inside the unit e os ESSEX ooreo b lt 5 7 It is recommended to replace the carbon filter every 3 to 6 months Control Panel 2 Cooling Air Outlet 5 Air Filter 6 Air Inlet 3 Handle 7 Exhaust Air Outlet 4 Castors 8 Cord Hanger 9 Water Stopper Rubber Plug Inside Accessories 10 Adaptor for insertion over the hose and into the back of the air conditioner Il Exhaust Hose 12 Foam Strip for filling the open window space and with a hole for connection
Download Pdf Manuals