Home
StorCase 1 Bay Data Express DE100i-A100 (DE100I
Contents
1. 6 Introduction Master Drive Select 0 Factory Default Slave Drive Device Spin Down Up Jumper J6 Select 1 On Factory Default Device Spin Down Up Activity Indicator enabled DC Power Off Device Spin Down Up Activity Indicator disabled J6 mo O0000000000000000000R J2 0000000000 000000000 0421A W Pin 1 Figure 5 Receiving Frame Rear Panel StorCase Technology Inc DE100i A100 User s Guide Rev C02 Installation 7 INSTALLATION Installing the Drive into the Carrier NOTE A 2 Phillips screwdriver will be required during this procedure While performing the steps in this section work on a soft surface to prevent excessive shock to the drive being installed Also refer to the manufacturer s documentation provided with the drive 1 Remove the drive from its protective packaging 2 Plastic Drive Bezel If the drive came equipped with a plastic front bezel it must be removed before installing the drive into the drive carrier 3 Master Slave Drive Selection In most cases the drive will be factory configured as a Master Ultra ATA133 drive using a jumper plug on the drive itself No con figuration changes are required For multiple drive configurations it is necessary to set the first Ultra ATA133 drive as Master and the second Ultra ATA133 drive to Slave This can be done by changing the jumper on the Ultra ATA133 drive itself refer to your drive manufacturer docume
2. Down Up Timer Switch Unit ID Number _ Indicator Receiving Frame Front Activity Indicator Key Lock Drive Power Switch 0231A Figure 3 Receiving Frame Front Panel StorCase Technology Inc DE100i A100 User s Guide Rev C02 Introduction 5 Drive Activity Indicator Carrier Removed Carrier Installed Carrier Installed from Receiving Frame unlocked locked n 0064B The number 2 display is for illustration purposes only It can be any valid Unit ID number However the letter u above middle will appear as illustrated Figure 4 Receiving Frame Unit ID Number and Activity Display Receiving Frame Rear Panel Figure 5 DC Power Connector J3 The DE100i A100 uses a standard 4 pin DC Power Connector to accept DC power Connector J2 The input output connector provides a standard interface for all IDE signals See Table 3 on page 13 for J2 pin assignments Master Slave Selection Jumper J5 Master Drive configuration default Forces master drive configuration on receiving frame Change jumper to set slave drive configuration Refer to Table 1 on page 12 for further information Device Spin Down Up Timer Jumper J6 Jumper installed Factory Default enables device spin down up visual indicator Receiving frame unit ID number display Figure 4 will flash to indicate device spin down up DE100i A100 User s Guide Rev C02 StorCase Technology Inc
3. C to 75 C Relative Humidity 10 to 80 10 to 90 Altitude 1000 to 50 000 ft 1000 to 50 000 ft 304m to 15240m 304m to 15240m Shock 10g 60g Non condensing with maximum gradient of 10 per hour 211 msec pulse width 1 2 sine wave Physical Specifications Carrier Receiving Frame 1 68 42 7mm 1 70 43 2mm 4 67 118 6mm 5 75 146 1mm 7 38 187 5mm 8 18 207 8mm 1 1Ib 0 50kg 1 25lb 0 57kg with carrier removed Chassis Reliability Maintainability MTBF 500 000 Hours MTTR 5 Minutes Preventive Maintenance None Electrical Specifications Input 5V 65mA 12V 400 DE100i A100 User s Guide Rev C02 StorCase Technology Inc 16 Appendix A Specifications Dimensions 2 06 3 13 Receiving 52 3mm 79 5mm _ Frame 0 50 r with Carrier 5 75 146 1mm 5 50 139 7mm lo Ce E 0 25 L 0 15 6 4mm 313 3 8mm 79 5mm 6 32 x 4 Bottom Carrier Only 1 68 42 7mm Cc Cc 467 gt 3 75 118 6mm 3 95 3mm C Cc Cc CA EE 0 26 6 6mm 0008A Figure A 1 DE100i A100 Physical Dimensions Dimensions are for reference only StorCase Technology Inc DE100i A100 User s Guide Rev C02 Appendix B Attaching the ON OFF Key 17 Appendix B Attaching the ON OFF Key The following information describes the necessary steps
4. 3 Drive Lock Keys Mounting Screws 4 Receiving Frame 8 6 32 Phillips F H Mounting 5 DriveCarrier Screws Figure 1 Package Contents StorCase Technology Inc DE100i A100 User s Guide Rev C02 Introduction 3 General Description NOTE ForUltra ATA133 133MByte sec operation an Ultra ATA 133 controller and hard drive s and appropriate 40 pin 80 conductor cable are required The StorCase Technology Data Express DE100i A100 is a removable drive carrier and receiving frame designed to provide durable and reliable mounting for 3 5 Ultra ATA133 drives within 5 25 half height peripheral slots Figure 2 It is downward compatible with earlier technology IDE drives The DE100i A100 allows a drive to be removed and transported to another DE100i A100 equipped computer or expansion chassis and also provides the ability to secure sensitive data by removing and storing the drive safely for future use Receiving Frame Drive Carrier Figure 2 DE100i A100 Receiving Frame and Carrier This User s Guide describes the steps required to install the StorCase Data Express DE100i A100 removable enclosure inside a computer peripheral bay This guide supplements documentation provided with the host computer system operating system and the drive to be installed within the Data Express carrier DE100i A100 User s Guide Rev C02 StorCase Technology Inc 4 Introduction Receiving Frame Front Panel Figure 3 Ke
5. Technology Inc DE100i A100 User s Guide Rev Table of Contents INTRODBUGTION 5 Ege pe p deb TUE Eq RETURNS 1 Packaging Information EE Serial NUFIrbers ocio e ca ae az aka Zi xara ke A de OR 1 Package Contents e eterne be p Ud di ET E EERR 2 General Description d Receiving Frame Front Panel Az xiya rr cce e 4 Receiving Frame Rear Panel seems 5 INSTALLATION 5 e Pecado deseo ipee ORE GE REN AA ad Installing the Drive into the Carrier Drive Activity Indicator Connector J5 Installation 5 ESTEE o OI Installing the Receiving Frame Selecting the Unit ID Number Unit ID Select Switch Settings Connector J2 APPENDICE Sa ote tod ob eb d Co a po HH OE GEO ds Appendix A Specifications Dimensions sss Appendix B Attaching the ON OFF Key Appendix C Optional Accessories Carrying Case Drive Cover Solenoid Drive Lock Reader s Comments DE100i A100 User s Guide Rev C02 StorCase Technology Inc vi Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure A 1 Figure B 1 Figure C 1 Figure C 2 Figure C 3 Figure C 4 Table 1 Table 2 NOTICE List of Figures Package Contents ert o to oe dte tires 2 DE100i A100 Receiving Frame and Carrier sse 3 Receiving Frame Front Panel as R
6. The following StorCase products are covered by this warranty for a period of seven 7 years from the original date of purchase from StorCase or its authorized resellers all Data Express removable device enclosures and all Data Silo Data Stacker and InfoStation external expansion chassis except for those components integrated into or purchased separately for use with these products which are identified and covered by the three year or hard drive warranties described below All StorCase interface cables and other accessories specifically intended for use with the StorCase products identified above are also covered by this 7 year warranty Three Year Warranty The following components integrated into or purchased separately for use with StorCase Data Express Data Silo Data Stacker and or InfoStation products are subject to warranty for a period of three 3 years from the original date of purchase from StorCase or its authorized resellers all RAID controllers power supplies fans and blowers Two Year Warranty The following StorCase products are covered by this warranty for a period of two 2 years from the original date of purchase from StorCase or its authorized resellers all RhinoSUR fixed external expansion chassis model types FJR and all RhinoJR removable device enclosures model types RJR One Year Warranty All StorCase products identified as Reconditioned or Special Inventory are covered by this warranty for a period o
7. improper packaging will not be covered by this warranty The StorCase factory service center is located at 17650 Newhope Street Receiving Dock Gate 4 Fountain Valley CA 92780 U S A Free Technical Support StorCase provides free technical support If you experience any difficulty during the installation or subsequent use of a StorCase product please contact StorCase s Technical Support Department prior to servicing your system This warranty covers only repair or replacement of defective StorCase products as described above StorCase is not liable for and does not cover under warranty any costs associated with servicing and or installation of StorCase products StorCase Technical Support can be reached in the U S at 714 438 1858 or toll free at 888 435 5460 U S and Canada only StorCase European Technical Support can be reached in the U K at 44 0 1932 738900 Disclaimers The foregoing is the complete warranty for the products identified above and supersedes all other warranties and representations whether oral or written StorCase expressly disclaims all warranties for the identified products which are not stated herein including to the extent permitted by applicable law any implied warranty of merchantability or fitness for a particular purpose In no event will StorCase be liable to the purchaser or to any user of a StorCase product for any damages expenses lost revenues lost savings lost profits or any other
8. incidental or consequential damages arising from the purchase use or inability to use a StorCase product even if StorCase has been advised of the possibility of such damages Copyright 2005 StorCase Technology All rights reserved All registered 6 trademarks are the property of StorCase Technology All other logos and trademarks on 565 are properties of their respective companies osl DE100i A100 User s Guide Rev C02 StorCase Technology Inc iv Kingston Technology Affiliate E Storcase TECHNOLOGY Safest Place for Your Data Declaration of Conformity Company Name StorCase Technology Inc Corporate Office Address 17600 Newhope Street Fountain Valley CA 92708 Manufacturing Address 17600 Newhope Street Fountain Valley CA 92708 Product Name Data Express DE100 Model Number DE100i XXXX XXX Conforms to the following standards EMC Directives ITE Emission 89 336 EEC EN 50081 1 EN 61000 3 2 Harmonic Current EN 61000 3 3 Voltage Fluctuations and Flicker EN 50082 1 EN 61000 4 2 EN 61000 4 5 EN 61000 4 3 EN 61000 4 6 EN 61000 4 4 En 61000 4 8 EN 61000 4 11 Low Voltage Directive EN 60950 73 23 EEC Safety Standards CAN CSA C22 2 No 950 95 CSA NRTLIC UL 1950 TUV EN 60950 2000 EMI Standards FCC Part 15 Class B EMC Standards AS NZS 3548 Information Technology Equipment Year of Manufacture Signature Full name Position StorCase
9. 0i A100 carrier Contact your StorCase dealer for further details and ordering information StorCase Technology Inc DE100i A100 User s Guide Rev C02 Appendix C Optional Accessories 19 Drive Cover 4 n 1 Slip Drive Cover ON d Lip into Top Hear o of Carrier The a ZAN Cd i Sides of the Cover 74 3 Slide Drive Cover Will Fit Between Forward Making Certain the Drive and the Front Cover Lip is Inside Carrier Mounting Carrier Fasten Screws Holes Must be Towards Rear of Carrier Drive Cover 2 Swing Drive Cover Down Covering the Drive Make Mounting Certain You Do Holes Not Damage Qa Connector Pins or Cables Disk Carrier 0067 Full Drive Cover optional Figure C 2 Full Drive Cover The full drive cover P N DX100 COV is an attractive metal cover which can provide additional protection to the drive preventing foreign material from coming in contact with the drive and cables The full drive cover is similarto the cable cover provided with the DE100i A100 except the full drive cover protects the drive as well as the cables It is easily installed with two 2 316 32 Phillips Flat Hd screws as shown in the illustration above Drive Plug 0429 Figure C 3 Drive Plug The drive plug P N DX100 PLUG is designed to fill system or external enclosure bays that are occupied by receiving frames that have no carrier units installed The purpose of the plu
10. StorCase Technology Data Express DE100i A100 Removable Ultra ATA133 Drive Enclosure User s Guide StorCase Technology Data Express DE100i A100 Removable Ultra ATA133 Drive Enclosure User s Guide Part No D89 0000 0103 C02 October 2005 Kingston Technology Affiliate Ir Storcase ECHNOLOGO Y Safest Place for Your Data 9 StorCase Technology Inc 17600 Newhope Street Fountain Valley CA 92708 9885 Phone 714 438 1850 Fax 714 438 1847 DE100i A100 User s Guide Rev C02 StorCase Technology Inc LIMITEDWARRANTY STORCASE TECHNOLOCY Incorporated StorCase warrants that its products will be free from defects in material and workmanship subject to the conditions and limitations set forth below StorCase will at its option either repair or replace any part of its product that proves defective by reason of improper workmanship or materials Repair parts or replacement products will be provided by StorCase on an exchange basis and will be either new or reconditioned to be functionally equivalent to new This warranty does not cover any product damage that results from accident abuse misuse natural or personal disaster external power surge or failure or any unauthorized disassem bly repair or modification StorCase will not be responsible for any software firmware or other customer data stored within or interfacing with a StorCase product Duration of Warranty Seven Year Warranty
11. eceiving Frame Unit ID Number and Activity Display l 5 Receiving Frame Rear Pan l x na y anla nal l da lak karan rk aia k 6 Drive Carrier Circuit Board ss Drive Installation Assembly sssse e 8 Master Slave Configuration Jumper J5 9 Receiving Frame Mounting Holes Unit ID Select Switch Location sss DE100i A100 Physical Dimensions Lii kk 16 Attaching the ON OFF Key keke keke kk kek k k k kk 17 Carrying Gase teh pt e RO Ce PH C RR 18 Full Drive Cover ode 19 Dive Aa bl 19 Solenoid Mechanism sss 20 List of Tables Unit ID Select Switch Settings sss 12 Interface Signals 45 44 55 a ada ad b E BA NE EA i A n k 13 This User s Guide is subject to periodic updates without notice While reason able efforts have been made to ensure accuracy of this document Stor Case Technology Inc assumes no liability resulting from errors or omissions in this publication or from the use of the information contained herein Please check the StorCase web site at http www storcase com or contact your StorCase representative for the latest revision of this document StorCase Technology Inc DE100i A100 User s Guide Rev Introduction 1 INTRODUCTION Packaging Information The StorCase Technology Data Express system is shipped in a con
12. es 3 16 Flat HD 6 32 x 3 16 ji Flat HD 0084A Figure 7 Drive Installation Assembly StorCase Technology Inc DE100i A100 User s Guide Rev C02 Installation 9 Installing the Receiving Frame The drive should be installed into the carrier before installing the receiving frame into the mounting bay of a computer or expansion chassis NOTE Use a 2 Phillips screwdriver for this procedure 1 Turn OFF power to the computer 2 Open the computer system according to the manufacturer s instructions If neces sary temporarily remove any expansion boards that may make installation difficult 3 Select the Master Slave configuration on the rear of the receiving frame by placing a jumper on the appropriate J5 pins Figure 8 Remove the jumper if you wish to use the Unit ID Select switch on the receiving frame to configure the Master Slave drive selection Refer to Table 1 for further information NOTE The unit ID select switch configures the unit ID display only The master slave setting on must still be set on the drive itself refer to the drive manufacturer s documentation for further information Master Drive Select Factory Default p Drive Select J5 E8 0423A Figure 8 Master Slave Configuration Jumper J5 4 With the drive carrier locked in place inside the receiving frame install the DE100i A100 into the 5 25 drive opening in the computer or expansion chassis Use the appropr
13. f one 1 year from the original date of purchase from StorCase or its authorized resellers Reconditioned products may only be exchanged for reconditioned products Hard Disk Drive Warranty All hard disk drives purchased from StorCase or through its authorized resellers whether purchased separately or integrated into StorCase products are subject to the warranty terms and conditions provided by the drive manufacturer Third Party Software Warranty All third party software purchased from StorCase for use with and or as part of StorCase products is subject to the warranty terms and conditions provided by the software manufacturer StorCase Technology Inc DE100i A100 User s Guide Rev Warranty Claim Requirements To obtain warranty service the defective product must be returned to your local authorized StorCase dealer or distributor or with prior StorCase approval to the StorCase factory service center For defective products returned directly to StorCase a Return Material Authorization RMA number must be obtained by calling StorCase Customer Service at 714 445 3455 The RMA number must be prominently displayed on the outside of the return package Shipments must be freight prepaid and insured and must include the product serial number a detailed description of the problem experienced and proof of the original retail purchase date Products must be properly packaged to prevent damage in transit Damage resulting from
14. g is to provide an attractive and functional method of directing proper air flow to the other installed devices in the system or external enclosure DE100i A100 User s Guide Rev C02 StorCase Technology Inc 20 Appendix C Optional Accessories Solenoid Drive Lock The factory installed solenoid option prevents premature removal of the carrier and drive unit until the target drive has fully spun down For disk drives this period of time can range from 15 40 seconds depending on the type of drive being used e g Barracuda drives require up to 50 seconds Referto the drive manufacturer s documentation for specific drive information The solenoid lock is controlled by a timing switch located on the side of the receiving frame The solenoid option provides an extra step in drive protection by preventing the removal and movement of the drive until the drive motor has fully stopped Shown with Outer Shell of Receiving Frame Removed Spin Down Timer Solenoid Control Pivoting Lock Mechanism Rotating Pawl 0286 Figure C 4 Solenoid Mechanism StorCase Technology Inc DE100i A100 User s Guide Rev C02 21 Reader s Comments Please take a few moments when your computer system is up and running to send us your ideas and suggestions for improving our products and documentation Did the installation go smoothly for you Are there any changes you would like us to make either with the hardwa
15. iate guides to position the Data Express and fasten it into place with the four 4 6 32 Phillips screws provided Figure 9 illustrates the location of the mounting holes Mounting holes are provided on each side and the bottom of the receiving frame to accommodate a variety of mounting configurations Use the mounting holes which best suit the computer or expansion chassis configuration Note that bottom mounting holes require self tapping screws not provided 5 Adjust the front of the receiving frame so the carrier slides freely in and out on the receiving frame guides The position of adjoining peripheral units may require ad justment DE100i A100 User s Guide Rev C02 StorCase Technology Inc 10 Installation 10 11 Front of Unit Q00000 2 Mame Mounting Holes Right Mounting Holes Bottom 0086 Figure 9 Receiving Frame Mounting Holes Connectthe I O cable from the host adapter to the receiving frame ThePin 1 indicator onthe cable must be properly aligned Refer to Figure 5 for the correct Pin 1 location Connect the power cable from the DC power supply in the computer or expansion chassis to the power connector on the DE100i A100 receiving frame Refer to Figure 5 for the DE100i A100 receiving frame power connector location Replace any expansion boards that may have been removed earlier Replace the system cover according to the manufacturer s instructions Reconnect any syste
16. jumpers removed from J5 Master Slave Master Slave NOTE The unit ID number display is for ID display purposes only The master slave setting must still be set on the drive itself refer to the drive manufacturer s documentation for further information StorCase Technology Inc DE100i A100 User s Guide Rev C02 Installation 13 Connector J2 The I O connector J2 pin assignments are as follows Table 2 AT IDE Interface Signals Host Reset Host Data 7 Host Data 8 Host Data 6 Host Data 9 Host Data 5 Host Data 10 Host Data 4 Host Data 11 Host Data 3 Host Data 12 Host Data 2 Host Data 13 Host Data 1 Host Data 14 Host Data 0 Host Data 15 Ground Key DMARQ Ground DIOW Ground DIOR Ground Reserved Reserved Reserved Ground IRQ 14 Host 1016 AT Host ADDR 1 PDIAG 16 Host ADDR 0 Host ADDR 2 Host CSO Host CS1 DASP Ground Indicates an active low signal Signal direction is with respect to the host I indicates To the host O indicates From the host The PDIAG and DASP signals are used for communication between master slave and the host DE100i A100 User s Guide Rev C02 StorCase Technology Inc 14 APPENDICES StorCase Technology Inc DE100i A100 User s Guide Rev C02 Appendix A Specifications Dimensions 15 Appendix A Specifications Dimensions Environmental Specifications Ambient Temperature 5 C to 50 C 45
17. m or peripheral cables removed earlier Turn ON power to the computer If the installation has been successful and all the cables have been properly attached the system should boot normally Although the computer may not recognize the DE100i A100 yet the front panel display on the DE100i A100 receiving frame should illuminate The new drive may need to be formatted or initialized prior to use with the operating system and applications software Referto the drive and or computer manufacturer s documentation for formatting information Selecting the Unit ID Number Verify that power is turned ON to the DE100i A100 receiving frame by turning on your computer A number will appear in the unit ID display window if the carrier is locked in place Unlock the DE100i A100 drive carrier and remove it from the receiving frame A u will be displayed initially when the unit is unlocked but will return to a number when the carrier is removed from the receiving frame StorCase Technology Inc DE100i A100 User s Guide Rev C02 Installation 11 WARNING Unlocking the carrier unit switches DC power off to the drive Since disk drives require a short amount of time to spin down allow about 15 seconds before pulling the carrier unit out of the receiving frame to avoid possible damage to the drive 3 Use the alignment tool supplied with the DE100i A100 to select the ID number of the disk drive Refer to Figure 10 for the location of
18. ntation for further information Drive Activity Indicator Connector J5 oo J5 00000000000000000000 00000000000000000000 Connector J2 0112A Figure 6 Drive Carrier Circuit Board Drive Activity Indicator Connector J5 Drive Carrier Circuit Board Jumper removed factory default disables drive activity indicator Figure 4 Jumper installed enables drive activity indicator NOTE If two 2 drives are installed with J5 enabled on both drives both drive activity indicators will flash simultaneously even if only one drive is being accessed DE100i A100 User s Guide Rev C02 StorCase Technology Inc Installation Installation Disk Drive Not Included Attach the I O cable on the drive carrier circuit board to the drive Refer to Figure 7 for an illustration of the installation process Attach the power cable on the drive carrier circuit board to the drive Carefully insert the drive into the drive carrier at an angle cable end first Make sure none of the cables are pinched Lower the front of the drive carefully into place Fasten the drive into the carrier with the four 4 screws provided as shown in Figure 7 Install the provided cable cover Cable 7 j Cover Provided VO Cable Drive Carrier Power Cable Drive Mounting gt oe Hardware 468 B TN Cable Cover Phillips 6 32 x SRI ei 3 Screws 2 pl
19. re itself or with the installation instructions Everyone at StorCase Technology is working toward the goal of providing you with the highest quality most cost effective products available on the market and we need your comments to guide our efforts We look forward to hearing from you soon Date Your Name Address Telephone To mail this page carefully remove it from the manual fold it staple or tape it shut and drop itin the mail To FAX this page carefully remove it from the manual or make a photocopy and FAX it to us at 714 438 1847 Thank you for taking the time to help us make our products better StorCase Technology Inc DE100i A100 User s Guide Rev C02 FOLD ALONG THIS LINE AND STAPLE SHUT NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES EEE BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 10686 SANTAANA CA HEZEK POSTAGE WILL BE PAID BY ADDRESSEE une Kingston Technology Affiliate e 9 Eee E Storcase TECHNO LOG Y Safest Place for Your Data 9 17600 NEWHOPE STREET FOUNTAIN VALLEY CA 92708 9885
20. tainer designed to provide protection and prevent damage during shipment The Data Express unit was carefully inspected before and during the packing procedure at the factory Bent or broken connectors orevidence of other damage to the Data Express should be reported to the shipper immediately Refer to Figure 1 for the package contents If the wrong Data Express model has been received please call your reseller or StorCase at 800 435 0642 to arrange for a Return Material Authorization RMA StorCase cannot ac cept returns which do not display an RMA number on the outside of the package Return the unit with all the original packing materials Before removing any component from its packaging discharge any static electricity by touching a properly grounded metal object Serial Numbers Both the Data Express receiving frame and carrier are labeled with serial numbers These numbers must be reported to the StorCase Customer Service Representative in order to receive a Return Material Authorization RMA for warranty claims Locate the serial number labels and record the numbers in the spaces provided below DE100i A100 User s Guide Rev C02 StorCase Technology Inc 2 Introduction Package Contents The DE100i A100 package contents include the following items If any items are missing or damaged contact your StorCase dealer for a replacement 1 Cable Cover amp Insert Sheet 2 Alignment Tool 7 6 32 Phillips Machine Hd
21. the ID Select Switch inside the receiving frame Table 2 lists the valid unit ID numbers available for the drive 4 After you have selected an appropriate unit number replace the DE100i A100 carrier in the receiving frame and LOCK IT IN PLACE NOTE The lock on the DE100i A100 receiving frame functions as a lock and a DC power switch for the carrier unit The lock must be engaged in order to supply power to the carrier and installed drive 5 Reboot the computer The new disk is now ready for use although it may have to be formatted or initialized prior to use with your operating system and applications software Drive Carrier Guide Receiving Frame Unit ID Number 2 Display Ca Lock and DC Power Switch Unit ID Select Rotating Switch Front of Unit 0087 Drive Carrier removed Figure 10 Unit ID Select Switch Location DE100i A100 User s Guide Rev C02 StorCase Technology Inc 12 Installation Unit ID Select Switch Settings The following table lists the Unit ID Select Switch settings and the valid AT IDE unit numbers Please note that all invalid switch settings have X s through them and result in a blank display in the receiving frame display window Table 1 Unit ID Select Switch Settings Unit ID Select Position 0 1 2 3 4 5 6 7 8 9 Ultra ATA 100 E i 5 Drive Unit ID Number Display Blank 0 1 Blank Blank 2 3 Blank Blank Blank with both
22. to attach the ON OFF key to the key lock mechanism so that it is non removable preventing accidental key loss The procedure can be reversed at a later date to revert back to a removable key Access Hole Pawl Key Lock Make certain power is OFF to the receiving frame Locate the rectangular shaped key lock mecha nism access hole on the inside of the receiving frame Note thatthe pawlis in an upright position Insert the key into the lock go d e Rotate the key 90 degrees counterclockwise so that the pawl is visible in the access hole as shown in the figure at left Using the provided alignment tool unscrew and remove the pawl from the access hole 3 END i3 A Rotate the key 180 degrees clockwise or coun terclockwise Reinstall the pawl into the access hole with the alignment tool The key lock has now been reconfigured 0156 Figure B 1 Attaching the ON OFF Key DE100i A100 User s Guide Rev C02 StorCase Technology Inc 18 Appendix C Optional Accessories Appendix C Optional Accessories Carrying Case 320FW 13 Figure C 1 Carrying Case The optional molded plastic carrying case P N S20E104 is designed to transport the DE100i A100 carrier from one site to another in a safe impact and moisture resistant environment Its compact dimensions 7 long x 9 wide x 3 5 high make it easy to carry and to store The foam lining is contoured to fit a single DE10
23. y Lock Drive Power Switch performs three 3 functions The key lock assures proper seating of the drive carrier within the receiving frame turns power to the drive carrier on and off and prevents unauthorized removal or installation of the carrier Forthe computerto access data on the DE100i A100 drive the key must be turned counterclockwise to the locked position Unit ID Number Display Figure 4 shows the physical address of the DE100i A100 drive carrier when the carrier is nstalled and Locked in the receiving frame or Removed from the receiving frame If the drive carrier is Installed but Not Locked a u will be displayed The unit ID number is selected by means of the unit ID select switch located inside the receiving frame using a special alignment tool supplied with the DE100i A100 This procedure is explained later during the installation process Activity Indicator is a small dot next to the Unit ID Number which flashes when the host computer is accessing data on the DE100i A100 carrier Refer to Figure 6 on page 7 and section Drive Activity Indicator Connector J5 on page 8 for further information Device Spin Down Up Timer may be disabled by removing Jumper J6 P1 P2 Figure 5 This feature allows the receiving frame unit number display to provide a visual indication of drive spin down up activity High Insertion Count Mating Connector Carrier Guide X All Steel _ Receiving D d Frame Device Spin
Download Pdf Manuals
Related Search
Related Contents
サンフ40 N 取扱説明書く保証書付き) Copyright © All rights reserved.
Failed to retrieve file