Home

Broan-NuTone N-QT9093WH Combination Heater Heater Kitchen Hood

image

Contents

1. U READ amp SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS Heat A Ventlite MODELS QT 9093 SERIES HEATER IMPORTANT DO NOT MOUNT OVER TUB OR IN SHOWER STALL ENCLOSURE PRECAUTIONS Observe all requirements in this instruction sheet and all markings appearing on the unit Check all operations of the unit after installation has been completed The heater housing must be grounded and the wiring must comply with all local electrical codes The flange of the rough in housing MUST be flush with the finished plaster or drywall surface to assure proper and absolutely safe operation e f plaster material paint base or paint is sprayed on the walls or ceiling the inside of the housing must be masked off to prevent this material from entering the housing The switch furnished must be wired in accordance with the SCREWS FIGURE 1 wiring diagram PREPARATION Refer to Figure 1 1 Loosen two screws holding grille in place Remove grille and set aside Remove housing switch assembly hanger bar and mounting brackets from carton 2 Loosen four 4 screws holding heater power unit in place Remove heater power unit and set aside MOUNTING TO OPEN JOISTS IN NEW CONSTRUCTION 1 Install hanger brackets in keyhole slots in housing Insert hanger bar through bracket opposite blower vent 2 Refer to Figure 2 Position housing between joists with exhaust vent in desired direction Secure side hanger brackets and ends
2. DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties WARRANTY SERVICE To qualify for warranty service you must a notify NuTone at the address stated below or telephone 1 800 543 8687 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Date of Installation Builder or Installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest NuTone Independent Authorized Service Center Residents of the contiguous United States Dial Free 1 800 543 8687 Please be prepared to provide Product model number Date and Proof of purchase The nature of the difficulty Residents of Alaska or Hawaii should write to NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio 45227 1599 Residents of Canada should write to Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 4820 Red Bank Road Cincinnati OH 45227 Product specifications subject to ch
3. of adjustable hanger bar to joists with screws or nails If joist Spacing is greater than 16 O C construct framing to support sides of housing Refer to Figure 3 Position housing against joists ua ee FIGURE 2 and secure with wood screws through keyhole slots in housing 3 Loosen screws securing hanger brackets to housing and adjust height of housing so that bottom flange will be flush with finished ceiling Tighten screws securely 4 Attach 4 round duct and run ductwork to the outside through wall or roof WIRING 115 120 volts 20 amp circuit only 12 gauge wire 1 Remove desired knockout from junction box and install a box connector not provided 2 Refer to Figure 4 Run 120vAC supply wiring to wall switch box Run wiring from wall switch box to heater Five conductors plus ground are required for independent operation of all functions PE 3 When a thermostat or timer switch is used connect at point marked T on Figure 4 WIRING 4 Make wiring connections using wire nuts Connect ground wire under ground screw in junction box 5 Push wiring back into junction box and install junction box cover being careful not to pinch wiring between cover and housing Secure cover FIGURE 3 FIGURE 4 COMPLETING INSTALLATION 1 Reinstall the heater unit and tighten four 4 screws securely 2 Plug fan and heater assemblies to receptacles on junction box cover 3 Install a 100 watt lamp in light
4. socket and 7 watt lamp in night light socket 4 Place grille over grille mounting screws and tighten 5 Check out all functions for proper operation INSTALLATION IN EXISTING CONSTRUCTION Refer to Figure 5 NOTE In existing construction hanger bar and mounting brackets are not used 1 Determine desired location of heater Area above heater must be free of plumbing and electrical wiring There must be enough clearance above ceiling for heater housing and installation of duct and wiring 2 Drill a small hole up through ceiling and insert a wire or nail to help in locating from above 3 Locate hole from above Center heater housing between joists and use the bottom flange of housing as a template to mark cutout Cut out hole in ceiling 4 Refer to Figure 3 Secure short pieces of 1 x 3 lumber nominal to joists on either side of opening Leave approximately 12 between top of ceiling so that flange of heater housing can slide under spacers If joist spacing is greater than 16 O C cut spacers of 2 x 4 lumber to fit between housing and joists 5 Place heater over opening and between spacers From below align housing so flange is flush with finished ceiling Secure to spacers with nails or wood screws though FIGURE 5 keyhole slots NOTE If necessary housing can be installed from below by removing vent blower vent housing and outlet box 6 Install 4 duct and refer to previous section of these instructions for Wiring and Co
5. ange without notice Printed in U S A Rev 10 01 Part No 85917
6. mpleting Installation U One Year Limited Warranty WARRANTY OWNER NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL