Home

Broan-NuTone N-79V Speed Control Kitchen Hood

image

Contents

1. e Rotate knob control to OFF position Fan will turn OFF TROUBLESHOOTING e Fan does not turn ON or does not run Multispeed Circuit breaker or fuse has tripped Fan is not connected to line Neutral Switch on Fan not set to HIGH position Fan and light miswired e Light does not turn ON Circuit breaker or fuse has tripped Bulb has burned out Lamp is not connected to line Neutral Switch on Fan unit controlling Light is not in the ON position if applicable Fan and light miswired Figure 1 Fan Speed Control Functions Rotary ON OFF Dimmer Rotary ON OFF Fan Speed Wiring Diagram 1 Single Location Control Application Fan Speed Dimmer Hot Black e Line 120VAC 60Hz Red Motor Hot Yellow Light Hot Black Black 1 Light Y Fan Green Ground White White Neutral White WIRE CONNECTOR OF CONDUCTOR COMBINATION CHART 1 12 w 1 to 3 14 16 or 18 2 12 w 1 14 w 1 16 or 18 2 12 w 1 16 w 1 or 2 18 2 14 w 1 to 3 16 18 or 20 4 16 w 1 or 2 18 20 or 22 1 14 w 1 to 4 16 18 or 20 2 14 w 1 to 3 16 18 or 20 2 14 w 1 16 w 1 or 2 18 or 20 3 14 w 1 or 2 18 or 20 4 14 w 1 16 or 18 2 16 w 1 18 w 1 or 2 20 or 22 1 14 w 1 18 w 1 to 3 20 3 14 w 1 16 w 1 18 20 22 3 14 w 1 18 w 1 20 or 22 CARACTER STICAS 4 Conecte los alambres de acuerdo con el
2. A SI TIENE DUDAS SOBRE proporcionan Instale la place de pared PS SaR El ventilador y la l mpara se conectaron ventiladores de cielo raso CUALQUIER PARTE DE ESTAS INSTRUCCIONES 6 Restaure la energ a el ctrica en el disyuntor o fusible incorrectamente de 4 velocidades A DEE EA CALIFICADO Revise la operaci n adecuada de la siguiente manera e La luz no se ENCIENDE SOBRECALENTAMIENTO Y POSIBLE DA O A ESTE Reductor de intensidad El disyuntor o el fusible se dispar DISPOSITIVO Y A OTRO EQUIPO NO LO INSTALE Gire la perilla de control superior hacia la La bombilla se fundi Control para ventiladores PARA CONTROLAR UN RECEPT CULO L MPARA derecha y hacia la izquierda y aseg rese de La l mpara no est conectada a la l nea Neutra FLUORESCENTE MOTOR O UN i que la intensidad de las luces DISMINUYA E conmutador de la Unidad del ventilador que controla la Capacidad nominal L nea de 1 5 A 120 VCA 60 Hz ELECTRODOM STICO OPERADO CON y AUMENTE de manera correspondiente l mpara no est en la posici n de ENCENDIDO si es TRANSFORMADOR QUE NO SEAN LOS Velocidad del ventilador aplicable Carga de l mpara incandescente VENTILADORES DE CIELO RASO Y LAS L MPARAS Coloque la perilla inferior en cada uno de El ventilador y la l mpata se conectaron incorrectamente con reducci n de intensidad de INCANDESCENTES et A EGODE a a eerie Figura 1 Funciones del control de intervalo completo INCENDIO O DESCARGA ELECTRICA ESTE de que la velocid
3. A DE CONECTADORES DE ALAMBRES DE COMBINACIONES DE CONDUCTORES todas ti iores e Bara tener oleo FUSIBLE Y COMPRUEBE QUE LA ENERG A EST 1 12 w 1 a 3 14 16 0 18 2 14 w 1 16 w 1 0 2 18 0 20 Broan NuTone a la direcci n y n mero de tel fono que aparecen abajo INTERRUMPIDA ANTES DE HACER EL 2 12 w 1 14 w 1 16 0 18 3 14 w 1 0 2 18 0 20 b proporcionar el n mero de modelo y la identificaci n de la pieza y CABLEADO 2 12 w 1 16 w 102 18 4 14 w 1 16 0 18 c describir la naturaleza de cualquier defecto en el producto o pieza 2 Quite la placa de pared y el conmutador existentes 2 14 w 1a3 16 18 0 20 2 16 w 1 18 w 1 0 2 20 o 22 En el momento de solicitar el servicio de la garantia debe presentar sies aplicable 4 16 w 1 0 2 18 20 o 22 1 14 w 1 18 w 1 a3 20 comprobante de la fecha de la compra original 3 Quite 34 1 9 cm de aislamiento de cada conductor 1 14 w 1a 4 16 18 0 20 3 14 w 1 16 w 1 18 20 22 aire AI tla mice rer de circuito Asegurese de que los extremos de los 2 14 w 1a3 16 18 o 20 3 14 w 1 18 w 1 20 0 22 alambres est n rectos e Neutro blanco
4. BLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BELIABLE FORINCIDENTAL CONSEQUEN TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNEC TION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 FEATURES e Controls a dimmer and fan in a single gang wall box e Four Preset fan levels e Full range rotary dimming e Ideal for any area where ceiling fan noise is distracting INSTALLATION INSTRUCTIONS WARNING TO BE INSTALLED AND OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS WARNING IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS CONSULT A QUALIFIED ELECTRICIAN WARNING TO AVOID OVERHEATING AND POSSIBLE
5. DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT DO NOT INSTALL TO CONTROL A RECEPTACLE FLUORESCENT LIGHTING A MOTOR OR A TRANSFORMER OPERATED APPLIANCE OTHER THAN APPROPRIATE CEILING FANS AND INCANDESCENT LAMPS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK THIS CONTROL IS TO BE USED WITH CEILING FANS THAT ARE MARKED AS SUITABLE FOR USE WITHA SOLID STATE FAN SPEED CONTROL AND IS RATED 120 VOLTS AC TOTAL LOAD 1 5 AMPERES MAXIMUM WARNING FOR USE ON CEILING PADDLE FANS WITH SPLIT CAPACITOR OR SHADED POLE MOTORS ONLY PLEASE REFER TO FAN MANUFACTURER S INSTRUCTIONS OR RATING LABEL ON THE MOTOR TO CONFIRM TYPE USE WITH ANY OTHER TYPES OF MOTORS OR EQUIPMENT MAY CAUSE OVERHEATING AND OR DAMAGE TO THE MOTORS OR EQUIPMENT OTHER CAUTIONS 1 USE ONLY ONE 1 SPEED CONTROL PER LOAD 2 DISCONNECT POWER WHEN SERVICING FIXTURE 3 USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO ALR OR CU AL MULTI FAN CONTROL Any number of fans of the same type may be controlled by a single fan speed control provided that the total amperage of the fans do not exceed the amperage of the fan speed control MULTI GANG INSTALLATION There is NO derating necessary for multi gang installations of this Quiet Fan Light Control TO INSTALL 1 WARNING TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING 2 Remove exist
6. DIAGRAMA DE La velocidad del ventilador aumentar o disminuir M O D E LOS x_ _aA lt _ __ _____ _ _ _ __AA 2 CABLEADO apropiado de la siguiente manera tuerza respectivamente seg n el nivel deseado e Controls a dimmer and fan in a single gang wall box apretadamente los hilos de cada alambre y con los e Gire la perilla de control a la posici n de APAGADO ey ae ino conductores de circuito empuje firmemente dentro del El ventilador se APAGARA Fu immi conectador de alambres apropiado Atornille hacia la ETEN a e a An a a a 79V 79W e Ideal for any area where ceiling fan noise is derecha los coneotadore eseaitaniinas de que no LOCALIZACI N Y RESOLUCI N DE PROBLEMAS _distracting aparezcan alambres desnudos debajo de los e El ventilador no se ENCIENDE o no funciona en m ltiples INSTRUCCIONES DE INSTALACION ls ltd de alambres Asegure cada conectador con velocidades ADVERTENCIA A INGTAI ACI N VO ELTISO Eldi t I fusibl di o Ja ADVERTENCIA LA INSTALACION Y O EL USO 5 Ahora se puede completar la instalaci n colocando E haces ie ein insake Unipolar una ubicaci n DEBEN HACERSE DE ACUERDO CON LOS cuidadosamente todos los alambres de manera que se nenes aade o ELECTRICOS deje espacio en la caja de salida para el control Monte el i posici n ALTO el vermiado no esta ajustado enla a z trol en la caj los tornillos d taj g Control silencioso para l mparas ADVERTENCI
7. MODEL 79V 79W Single Pole One location 4 Speed Quiet Ceiling Fan Light Control Fan Control Rating 1 5A 120VAC 60Hz Full Range Dimming Incandescent Lamp Load Rating 300W 120VAC 60Hz INSTALLATION INSTRUCTIONS 99042152D A O O BROAN BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRAN TIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan Nutone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S O
8. ad del ventilador cambie velocidad para ventiladores i eae CONTROL SE DEBE USAR CON VENTILADORES de manera correspondiente Capacidad nominal 300 W 120 VCA 60 Hz DE CIELO RASO QUE ESTEN MARCADOS COMO 7 LA INSTALACI N EST COMPLETA ADECUADOS PARA USARSE CON UN CONTROL DE 7 Conmutador a 8 OPERACI N R A VELOCIDAD DE ESTAD LIDO PARA E a ratorio de INSTRUCCIONES DE INSTALACI N VENTILADORES Y CON CAPACIDAD NOMINALDE Reductorde miensidad Cinta de j ENCENDIDOy 120 VOLTIOS DE CA CARGA TOTAL DE 1 5 e Gire hacia la derecha la perilla de control superior menaje fi APAGADO de AMPERIOS COMO MAXIMO La intensidad de la luz AUMENTAR de manera la velocidad del BROAN ASIEN OSES SNOT SS ee pa e Gire hacia la izquierda la perilla de control superior CAPACITOR DIVIDIDO O MOTORES DE POLO i i 4 Conmutador a E La intensidad de la luz DISMINUIR de manera SOMBREADO POR FAVOR CONSULTE LAS giratorio de INSTRUCCIONES DEL FABRICANTE DEL correspondiente GARANTIA LIMITADA DE UN ANO DE BROAN NUTONE ra O mn OLEA INDICADORA DEL e Gire totalmente hacia la izquierda la perilla de control ENCEN DIDO Broan NuTone garantiza Al consumidor comprador original de sus MOTOR PARA CONFIRMAR SU TIPO EL USO CON superior del reductor productos que tales productos estaran libres de detectos en materiales 2 3 x o mano de obra durante un periodo de un a o a partir de la fecha de la CUALQUIER OTRO TIPO DE MOTORES O EQUIPO Las luces se APAGARAN de intensidad compra or
9. do de un CONTROL DE MULTIPLES VENTILADORES ee negro a o como se especifica para la garant a expl cita Algunos estados no Se puede controlar cualquier n mero de ventiladores del permiten la limitaci n de la duraci n de una garant a impl cita de mismo tipo con un solo controlador de velocidad para manera que las limitaciones antedichas pueden no aplicar a usted ventiladores suponiendo que el amperaje total de los L mpara del LA OBLIGACI N DE BROAN NUTONE PARA REPARAR O ventiladores no exceda el amperaje del control de L nea de ventilador Ventilador REEMPLAZAR AOPCI N DE BROAN NUTONE SER EL NICO Y velocidad para ventiladores 120 VCA 60 Hz Verda EXCLUSIVO RECURSO DEL COMPRADOR BAJO ESTA GARANT A A y BROANNUTONE NO SERA RESPONSABLE POR DANOS INSTALACION DE MULTIPLES ACOPLAMIENTOS Tierra INCIDENTALES RESULTANTES O ESPECIALES QUE SURJAN DE NO es necesaria la reducci n para las instalaciones de Blanco Blanco O EN RELACI N CON EL USO O RENDIMIENTO DEL PRODUCTO m ltiples acoplamientos de este control silencioso para Algunos estados no permiten la exclusi n o la limitaci n de da os ventiladores l mparas Paras oud o Pan les de manera que es posible que la limitaci n INSTALACION antedicha no aplique en su caso ks Esta garant a le da derechos legales espec ficos y usted puede tener te ahahaha MUERTE ANPR L otros derechos que varian entre estados Esta garantia sustituye a ENERG A EL CTRICA EN EL DISYUNTOR O TABL
10. iginal NO EXISTEN OTRAS GARANT AS EXPRESAS NI PUEDE CAUSAR SOBRECALENTAMIENTO Y O Velocidad del ventilador IMPL CITAS INCLUSIVE PERO SIN LIMITARSE A GARANT AS DANOS A LOS MOTORES O AL EQUIPO e Gire la perilla de control inferior a cada uno de los cuatro IMPL CITAS DE COMERCIALIZACI N O IDONEIDAD PARA UN OTRAS PRECAUCIONES niveles M X ALTO MEDIO y BAJO PROP SITO PARTICULAR USE S LO UN 1 CONTROL DE VELOCIDAD Durante este per odo de un a o Broan NuTone a su criterio reparar POR CARGA y oa p T o reemplazar sin cargo alguno cualquier producto o pieza que se 2 DESCONECTE LA CORRIENTE EL CTRICA Diagrama de cableado 1 Aplicaci n del control de una ubicaci n e e a a aea E Ya CUANDO D SERVICIO AL APARATO Velocidad del ventilador Reductor de intensidad ESTA GARANT A NO SE EXTIENDE A ARRANCADORES Y TUBOS A DE LAS L MPARAS FLUORESCENTES Esta garant a no cubre a 3 USE ESTE DISPOSITIVO SOLO CON ALAMBRES mantenimiento y servicio normales ni b ning n producto o piezas que DE COBRE O ALAMBRES REVESTIDOS DE se hayan sometido a uso inadecuado negligencia accidente COBRE CON ALAMBRE DE ALUMINIO USE Rojo Motor Vivo mantenimiento o reparaci n inadecuada no hecha por Broan Nutone SOLO DISPOSITIVOS MARCADOS COMO CO instalaci n incorrecta o instalaci n en contra de las instrucciones de ALR O CU AL arillo L mpara Vivo instalaci n recomendadas 4 E i La duraci n de cualquier garantia impl cita se limita al per o
11. ing wallplate and switch if applicable 3 Remove 3 4 1 9 cm of insulation from each circuit conductor Make sure the ends of wires are straight 4 Connect wires per appropriate WIRING DIAGRAM as follows Twist strands of each lead tightly and with circuit conductors push firmly into appropriate wire connector Screw connectors on clockwise making sure no bare wires show below the wire connectors Secure each connector with electrical tape Installation may now be completed by carefully positioning all wires to provide room in outlet box for control Mount control into box with mounting screws supplied Attach wallplate Restore power at circuit breaker or fuse Check for proper operation as follows Dimmer Rotate top knob control clockwise and counter clockwise and ensure that the lights DIM or BRIGHTEN accordingly Fan Speed Position the bottom knob to each of the four levels MAX HIGH MEDIUM and LOW refer Figure 1 Ensure that fan speed changes accordingly 7 INSTALLATION IS COMPLETE TO OPERATE Dimmer Rotate top knob control clockwise Lights will BRIGHTEN accordingly Rotate top knob control counter clockwise Lights will DIM accordingly Rotate top knob control fully counter clockwise Lights will turn OFF Fan Speed Rotate bottom knob control to each of the four levels MAX HIGH MEDIUM and LOW Fan will increase or decrease in speed respectively for desired level

Download Pdf Manuals

image

Related Search

Related Contents

CC-Link System Optical Repeater Module User`s Manual    Mode d`emploi  none I 1501 Instructions / Assembly  Philips IronCare Anti-scale cartridge GC025/10  DD 200 - Hilti  Directions For Use - Dentsply International    Qui est le Gecac ? Pratique Nos intervenants aux conférences  '94 Mazda RX-7 Factory Service Manual  