Home

Broan-NuTone L500L In-Line Exhaust Fan Kitchen Hood

image

Contents

1. DUCTING OPTIONS BLOWER DISCHARGE POSITIONS DUCT CONNECTOR DUCT CONNECTOR Change blower amp duct connector positions for right angle discharge Blower and duct connector in right angle discharge position Blower and duct connector in straight through dis charge position Factory shipped DUCTING Right angle blower discharge 4 2 X 18 TO 10 ROUND TRANSITION N gt lt N 077777777777 N Typical ductwork connection to a ventilator converted to right angle discharge USE AND CARE Ventilator is designed for continuous operation If desired it may be controlled using an on off switch or a solid state variable speed control Follow wiring instructions packed with control and adhere to all local and state codes and the National Electrical Code WARNING To reduce the risk of electric shock disconnect from power supply before servicing To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor BRSAN L400L oa il Page 4 SERVICE PARTS SERVICE PARTS 97014744 Housing Assembly 97014728 Mounting Bracket
2. A e MODELS BRESAN L400L L500L L700L Page 1 LOSONE SELECT VENTILATORS In Line 120V WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR IN JURY TO PERSONS OBSERVE THE FOLLOWING 1 9 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a quali fied person s in accordance with all applicable codes and stan dards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Con ditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities Ducted fans must always be
3. Support 2 oblig 98009449 Registre 2 oblig 97014822 Ensemble de clapet de registre 2 oblig 99150415 Vis 8 18 x 18 oblig 98005512 Plaque de c blage 99150471 Vis de terre 10 32 x Y 2 oblig 98005513 Couvercle de la bo te de c blage 99400035 R ducteur de tension 97006039 Harnais fils 99260477 Ecrou 14 20 12 oblig 97014745 Volute 2 oblig 99110805 Roue de soufflerie 98009399 Bague d arriv e 2 oblig 99080486 Moteur L400L 99080487 Moteur L500L 99080488 Moteur L700L 97014794 Support de montage de moteur 99100497 Isolant de caoutchouc 4 oblig 99160380 Vis 10 24 x 7 8 4 oblig 99250399 Rondelle 4 oblig 99260306 Ecrou Hex 10 24 4 oblig 99250254 Rondelle 4 oblig 93260456 Ecrou Hex Flange 3 8 16 98009461 Barre de montage de volute Soufflerie ensemble inclut n l gende 5 et 11 23 97014817 L400L 97014819 L500L 97014821 L70OL 98009464 Panneau d access 99420470 Ecrou de panneau de access 4 oblig K EE IRERE 99150472 Vis de fixation de panneau de access a U 4 oblig 4 99150591 Vis 10 16 x 7 8 4 oblig Commander les pi ces de rechange par num ro de r f rence et non l aide du num ro de l gende Visserie standard peut tre achet e localement GARANTIE GARANTIE LIMIT E D UN AN DE BROAN Broan garantit l acheteur consommateur original de ses produits qu ils sont exempts
4. d charge de la soufflerie Installation des conduits d charge de soufflerie droit angle e UTILISATION ET ENTRETIEN e PI CES DE RECHANGE e GARANTIE Installateur Remetez ce manuel au protpri taire de maison Propri taire de maison Mode d utilisation et soin la page 11 A MODELES BRSAN L400L L500L L700L Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE Construction en cours C BLAGE CONDUIT TRANSITION CIRCULAIRE 4 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire NOIR AU DESSUS ARRI RE DU Supports E BOITIER pr assembl s pour plafonds de Y po 1 27 cm d paisseur FIL DE TERRE A PLAQUE DE CABLAGE SOLIVE DE PLAFOND 24 po 61 cm pun PLAQUE _ DE CABLAGE CONDUIT ENTREE 120 VCA CIRCULAIRE E eee gt Soufflerie pr assembl e DE 10 po 25 4 cm Le ventilateur peut tre branch depuis l ext rieur du bo tier en position de d charge Utiliser des connecteurs homologu s UL pour les branchements horizontale TRANSITION conform ment aux codes locaux en vigueur VIS DE 42 X 18 au 10 po FIXATION 11 4 x 47 au 25 4 cm circulaire INSTALLATION DES CONDUITS d charge de soufflerie dans ligne Appareil install dans un b timent en cours de construction MONTAGE construction termin e CHARPENTE 2 x 4 TRANSITION CHAPEAU DE TOIT c t large en bas 42 X 18 2 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10
5. de d fauts dans les mati res premi res ou la main d oeuvre pour une p riode d un an compter de la date d achat original IL N Y A PAS D AUTRES GARANTIES EXPRIMEES OU IMPLICITES INCLUANT MAIS NON PAS LIMIT AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER Pendant cette p riode d un an Broan son choix r parera ou remplacera gratuitement tout produit ou pi ce qui s av re d fectueux sous utilisation et service normaux CETTE GARANTIE NE COUVRE PAS LES DEMARREURS DE LAMPES FLUORESCENTES ET LES TUBES Cette garantie ne couvre pas a l entretien et le service normal ou b tout produit ou pi ce endommag par suite de mauvais usage n gligence accident entretien inappropri ou r paration autre que par Broan mauvais installation ou installation contraire au mode d installation recommand La dur e de toute garantie implicite est limit e une p riode d un an tel que sp cifi pour la garantie exprim e L ENGAGEMENT DE BROAN DE R PARER OU DE REMPLACER AU CHOIX DE BROAN SERA LA SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE BROAN NE SE TIENDRA PAS RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SP CIAUX SURVENANT A CAUSE DE OU EN RAPPORT L UTILISATION OU LA PERFORMANCE DE SES PRODUITS Cette garantie vous donne des droits l gaux sp cifiques et il se peut que vous ayez d autres droits Cette garantie annule toutes les garanties pr c dentes Pour le service sous garantie
6. o consecuentes por lo que esta limitaci n o exclusi n tal vez no se aplica en su caso Esta garant a le da derechos legales espec ficos y usted puede tener otros derechos que var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar para servicio bajo esta garant a usted debe a notificar a Broan en la direcci n que aparece abajo o al tel fono 1 800 637 1453 b dar el n mero de modelo y la identificaci n de pieza y c describir el defecto en el producto o pieza Al solicitar servicio bajo la garant a usted debe presentar evidencia de la fecha de compra original En los Estados Unidos llame Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 En Canada llame Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99042725F BROGAN VENTILATEURS LOSONE SELECT Montage au plafond mur 120 V LIRE ET CONSERVER CES INSTRUCTIONS AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES PERSONNELLES OBSERVEZ CE QUI SUIT 1 9 Utilisez cette unit seulement de la fagon pr vue par le fabricant Pour d autres renseignements contactez le fabricant l adresse ou au num ro de t l phone qui se trouve dans la garantie Avant d effectuer une r paration ou un entretien sur cet appareil coupez le courant au tableau d alimentation et verrouillez celui ci pour emp cher que la ten
7. po 25 4 cm TRANSITION 42 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CONDUIT CIRCULAIRE DE 10 po 25 4 cm gt Y CIRCULAIRE DE 10 po 25 4 cm SL TRANSITION 42 X 1872 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10 po 25 4 cm CIRCULAIRE DE 10 po 25 4 cm o FE Deux mani res de raccorder les conduits a un appareil pr mont autres c t s Z MATERIAU du bo tier et DE PLAFOND ere a 2 l envers pour FINI REMARQUE Veiller retirer le ruban adh sif d exp dition du volet que le bo tier SOLIVE DE du registre et s assurer que ce dernier s ouvre et se ferme librement soit au ras du PLAFOND 24 po l int rieur du conduit Utiliser du ruban adh sif pour assurer et plafond fini 61 cm centre tancher les raccords des conduits Appareil install dans un b timent d j construit BROAN MODELES L400L L500L L700L OPTIONS DE MONTAGE Des crous a six pans 14 20 fixent les supports au bo tier Desserrer et resserrer ou retirer et replacer les crous si n cessaire selon la position d sir e pour le support Supports en position pr assembl e Supports retourn s et fix s de part et d autre de la sortie du Sortie parall le aux solives bo tier B timent en cours de con Sortie perpendiculaire aux struction solives B timent d j construit e31 8 cm gt l 54 6 cm gt A Supports fix s de part et d
8. roc os de yeso polvo de construcci n etc Si el ventilador se instala en un rea sin acondicionamiento como por ejemplo en un tico Rodee el ventilador con mate rial de aislamiento t rmico para minimizar la posible condensaci n Para m s informaci n y requisitos favor leer la etiqueta de especificaciones del producto CONTENDIO Este manual consiste en las siguientes secciones e INSTALACI N T PICA Esta secci n muestra una instalaci n com n en una estructura nueva y en una existente Montaje estructura nueva Montaje estructura existente Conexiones el ctricas Colocaci n de conductos descarga derecha por del ventilador e OPCIONES DE MONTAJE e OPCIONES PARA LA CONEXI N EL CTRICA Colocaci n de la placa de conexiones e OPCIONES PARA LA COLOCACI N DE CONDUCTOS Posiciones de la descarga del ventilador Colocaci n de conductos descarga ngulo recto del ventilador e USO Y CUIDADO e PIEZAS DE SERVICIO e GARANT A Instalador Deje este manual con el due o de casa Due o de casa Informaci n del uso y mantenimiento en la p gina 7 A e MODELOS BRSAN L400L L500L L700L Pagina 6 INSTALACION TIPICA MONTAJE Estructura nueva CONDUCTO REDONDO DE 10 25 4 cm Abrazaderas de montaje enviadas de fabrica en posici n para montarse en una vigueta de Y 1 27 cm del techo 4 X 18 TO 10 1
9. tales productos estar n libres de defectos en materiales o mano de obra por un per odo de un a o a partir de la fecha de compra original NO HAY OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante este per odo de un a o Broan reparar o cambiar a su opci n y sin cobro cualquier producto o pieza que se encuentre defectuosa bajo uso y servicio normal ESTA GARANTIA NO SE EXTIENDE A ARRANCADORES DE LAMPARAS FLUORESCENTES Y TUBOS Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o pieza que hayan sido sometidos a uso equivocado negligencia accidente mantenimiento o reparaci n indebida excepto por Broan instalaci n defectuosa o instalaci n contraria a las instruc ciones de instalaci n La duraci n de cualquier garant a impl cita se limita a un per odo de un a o seg n se especifica en la garant a expl cita Algunos estados no permiten limitaci n a la duraci n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN DE REPARAR O CAMBIAR A OPCION DE BROAN SERA EL UNICO Y EXCLUSIVO REMEDIO AL COMPRADOR BAJO ESTA GARANTIA BROAN NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSECUENTES O ESPECIALES QUE SURJAN DE O EN RELACION A EL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exlusi n o limitaci n de da os incidentales
10. vous devez a aviser Broan l adresse ci dessous b donner le num ro du mod le et l identification de la pi ce et c d crire la nature de tout d faut dans le produit ou la pi ce Au temps de demander le service sous garantie vous devez pr senter une preuve de la date d achat original Aux E U comuniquez avec Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 Au Canada comuniquez avec Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99042725F
11. 1 4 X 47 a 25 4 cm TRANSICI N VIGUETA DEL TECHO se muestran centros de 24 61 cm CONDUCTO REDONDO Ventilador enviado de DE 10 25 4 cm f brica en posici n 4 X 1812 TO 10 de descarga horizontal 11 4X 47 a 25 4 om TORNILLO TRANSICION DE MONTAJE Unidad enviada de fabrica instalada en una estructura nueva MONTAJE Estructura existente 472 X 18 TO 10 11 4 X 47 a 25 4 cm TRANSICION ESTRUCTURA DE 2 X 4 5 08 x 10 2 cm con el lado del cableado hacia abajo 4 X 18 TO 10 11 4 X 47 a 25 4 cm TRANSICION CONDUCTO CONDUCTO REDONDO DE 3 REDONDO DE 10 25 4 cm 10 25 4 cm TORNILLO DE MONTAJE ABRAZADERAS DE MONTAJE conectadas a los lados opuestos del alojamiento y hacia abajo para que el alojamiento quede a nivel del cielo raso terminado MATERIAL DE TERMINADO DEL CIELO VIGUETA DEL TECHO RASO se muestran centros de 24 61 cm Unidad enviada de f brica instalada en una estructura existente INSTALACI N T PICA CONEXI N EL CTRICA PARTE SUPERIOR POSTERIOR DEL ALOJAMIENTO TIERRA A LA PLACA DE CONEXIONES __ PLACA DE CONEXIONES BLANCO A BLANCO LINEA DE ENTRADA DE 120 VCA 7 El ventilador se puede conectar desde el exterior del alojamiento Use conectores aprobados por UL en la conexi n en cumplimien to con los c digos locales COLOCACI N DE CONDUCTOS descarga derecha por del ventilador VENTILACI N
12. 2 req 98009449 Duct Connector 2 req 97014822 Damper Flap Assembly 2 req 99150415 Screw 8 18 x 4 18 req 98005512 Wiring Plate 99150471 Ground Screw 10 32 x Ya 2 req 98005513 Wire Box Cover 99400035 Strain Relief Bushing 97006039 Wire Harness 99260477 Nut 4 20 12 req 97014745 Scroll Assembly 2 req 99110805 Blower Wheel 2 req 98009399 Inlet Ring 2 req 99080486 Motor L400L 99080487 Motor L500L 99080488 Motor L700L 97014794 Motor Mounting Bracket 99100497 Rubber Isolator 4 req 99160380 Screw 10 24 x 7 8 4 req 99250399 Washer 4 req 99260306 Nut Hex 10 24 4 req 99250254 Washer 4 req 93260456 Nut Hex Flange 3 8 16 98009461 Scroll Mounting Channel Blower Assembly Complete Includes Key Nos 5 amp 11 23 97014817 L400L 97014819 L500L 97014821 L700L 98009464 Access Panel a j 99420470 Access Panel Nut 4 req KO BLOWER 99150472 Access Panel Mounting Screw 4 req ASSEMBLY 99150591 Screw 10 16 x 7 8 4 req Order replacement parts by PART NO not by KEY NO Standard hardware may be purchased locally WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUD
13. EN ELALERO CONDUCTO REDONDO DE 10 25 4 cm CONDUCTO REDONDO DE 10 25 4 cm 4 X 18 2 TO 10 11 4 X 47 a 25 4 cm TRANSICION ASS SSI NS SNS SSI SSII SSII SIN SSI SSII ISIN ST CODO REDONDO DE 10 25 4 cm Dos formas de conectar los conductos a una unidad enviada de f brica NOTA Aseg rese de quitar la cinta que fija la pesta a del regula dor durante la transportaci n y de que esta pesta a abra y cierre libremente dentro del conducto Utilice cinta de conductos para asegurar y hermetizar las conexiones de los conductos BROAN MODELOS L400L L500L L700L OPCIONES DE MONTAJE Las tuercas hexagonales de 1 4 x 20 aseguran las abrazaderas de montaje en el alojamiento Afloje y vuelva a apretar o quite y reem place las tuercas seg n sea necesario para colocar las abrazaderas de montaje en la posici n deseada ya z 54 6 cm gt n Abrazaderas de montaje en la posici n ajustada en f brica La salida queda paralela a las viguetas Estructura nueva Abrazaderas de montaje volteadas y montadas a los lados de la salida del aloja miento La salida queda perpendicular a las viguetas Estructura existente TITI Bi 8 a Abrazaderas de montaje montadas en los lados de la salida del alojamiento E l l 54 6 cm gt Abrazaderas de montaje volteadas para permitir un espacio adicional de aprox 1 La salida queda perpendicul
14. ING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you mus
15. ISIN IST I IIS IST IIS PE y a a N gt lt N 277777777777 Conexion tipica de los conductos al ventilador cambiado a descarga ngulo recto USO Y CUIDADO El ventilador esta dise ado para operar continuamente Si se desea se puede controlar usando un interruptor de encendido apagado o un control de estado s lido de velocidad variable Siga las instrucciones para las co nexiones el ctricas que vienen empacadas con el control y observe todos los c digos locales y estatales y el C digo El ctrico Nacional ADVERTENCIA Para reducir el riesgo de sufrir una descarga el ctrica antes de dar servicio al ventilador descon ctelo del suministro el ctrico Para limpiar el conjunto del ventilador Quite el panel de acceso desco necte el ventilador del alojamiento quite las tuercas de montaje del ventila dor y cuidadosamente saque el ventilador del alojamiento Use el adita mento apropiado de la aspiradora o un pa o suave y jab n o detergente suave para limpiar el rea de descarga y la rueda del ventilador NO PER MITA QUE ENTRE AGUA AL MOTOR Aseg rese de que el conjunto del ventilador est completamente seco antes de volverlo a instalar El motor est permanentemente lubricado No lubrique ni desmonte el motor BRSAN L400L iba al Pagi PIEZAS DE SERVICIO PIEZAS DE SERVICIO 07 euavew Piezaw CS 97014744 Conjunto del alojamiento 97014728 Abrazaderas de montaje se req 2 98009449 Conector del conducto se r
16. ar 2 54 cm a las viguetas La salida queda paralela a las Estructura nueva viguetas Estructura nueva l 54 6 cm gt la 54 6 cm Abrazaderas de montaje montadas en la parte superior de los lados del alojamiento Abrazaderas de montaje volteadas y montadas en la parte superior de los lados del La salida queda paralela a las alojamiento viguetas La salida queda paralela a las Estructura nueva o existente viguetas Estructura nueva o existente OPCIONES PARA LA CONEXI N EL CTRICA COLOCACI N DE LA PLACA DE CONEXIONES CONEXI N VERTICAL DEL CABLE DE ALIMENTACI N HORIZONTAL DEL CABLE DE ALIMENTACI N La placa de conexiones se monta a los lados o en la parte superior del alojamiento P gina 7 OPCIONES PARA LA COLOCACI N DE CONDUCTOS POSICIONES DE LA DESCARGA DEL VENTILADOR CONECTOR DEL CONDUCTO CONECTOR DEL CONDUCTO Cambie la posici n del conector del ventilador y del conducto para una descarga VENTILADOR Cambie la posici n del conector del ventilador y del conducto para una descarga ngulo recto Conector del ventilador y del conducto en posici n de descarga derecha por del ventilador ajuste de f brica COLOCACI N DE DUCTOS Descarga ngulo recto del ventilador CONDUCTO REDONDO DE WY 181 10 25 4 cm 4 X 18 2 TO 10 11 4 X 47 a 25 4 cm TRANSICI N LAI IS IS III IS III IIS IS III III IIS IS
17. autre de la sortie du bo tier Sortie perpendiculaire aux Supports retourn s pour donner environ1 po de d gagement suppl mentaire solives Sortie perpendiculaire aux B timent en cours de con solives struction B timent en cours de con struction 27 3 a 29 9 cm CD lu 54 6 cm p Supports retourn s et fix s sur le dessus de part et d autre du bo tier Sortie parall le aux solives B timent en cours de con struction ou d j construit OPTIONS DE C BLAGE POSITION DE LA PLAQUE DE CABLAGE Supports fix s sur le dessus de part et d autre du bo tier Sortie parall le aux solives B timent en cours de con struction ou d j construit BRANCHEMENT DU CABLE D ALIMENTATION ALA VERTICALE BRANCHEMENT DU 3 CABLE D ALIMENTATION AL HORIZONTALE La plaque de c blage se fixe sur le c t ou sur le dessus du boitier Page 11 OPTIONS D INSTALLATION DES CONDUITS POSITIONS DE LA DECHARGE DE LA SOUFFLERIE RACCORD DE CONDUIT RACCORD DE CONDUIT Modifier la position du raccord de soufflerie et de conduit Raccord de soufflerie et de conduit en position de d charge droit angle Raccord de soufflerie et de conduit en position de d charge dans ligne pr assembl e INSTALLATION DES CONDUITS d charge de soufflerie droit angle CHAPEAU DE TOIT TRANSITION 4 X 18 au 10 po 11 4 x 47 au 25 4 cm circulaire CONDUIT CIRCULAI DE 10 p
18. eq 2 97014822 Conjunto de la solapa de compuerta de tiro se req 2 99150415 Tornillos 8 18 x Y se req 18 98005512 Placa de conexiones 99150471 Tornillos de conexi n a tierra 10 32 x se req 2 98005513 Cubierta de la caja de conexiones 99400035 Buje de alivio de tensi n 97006039 Arn s de alambre 99260477 Tuercas 4 20 12 req 97014745 Conjunto del caracol 2 req 99110805 Rueda del ventilador 98009399 Anillo de entrada 2 req 99080486 Motor L400L 99080487 Motor L500L 99080488 Motor L700L 97014794 Abrazadera montaje de motor 99100497 Aislador de caucho se req 4 99160380 Tornillos 10 24 x 7 8 se req 4 99250399 Arandelas se req 4 99260306 Tuercas hex 10 24 se req 4 99250254 Arandelas se req 4 93260456 Tuerca hex pesta a 3 8 16 98009461 Ranura montaje de caracol Conjunto del ventilador completo Incluye clave N s 5 y 11 23 97014817 L400L 97014819 L500L J 97014821 L700L CONJUNTO DE 98009464 Panel de acceso VENTILADOR 99420470 Tuercas de panel de acceso se req 4 99150472 Tornillos de montaje de pane de acceso se req 4 99150591 Tornillos 10 16 x 7 8 se req 4 Pida las piezas de repuesto por N DE PIEZA no por N DE CLAVE Herraje estandar se puede comprar localmente GARANTIA GARANTIA LIMITADA DE BROAN DE UN ANO Broan le garantiza al consumidor comprador original de sus productos que
19. ipping tape is removed from the damper flap and that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight A e MODELS BRSAN L400L L500L L700L Page 3 MOUNTING OPTIONS 14 20 hex nuts secure mounting brackets to housing Loosen and re tighten or remove and replace nuts as necessary for desired mounting bracket position Qt LD Too Ne Mi 0 0 z j le 21 l 21 gt Mounting brackets in factory shipped position Outlet parallel to joists New construction Mounting brackets flipped over and mounted to outlet sides of housing Outlet parallel to joists Existing construction 11 2 ane qe le 21 gt Mounting brackets flipped over to give approx 1 more clearance Outlet parallel to joists New construction le 12 gt l Mounting brackets mounted to outlet sides of housing Outlet perpendicular to joists New construction 91 2 to lk 21 Mounting brackets mounted to top of sides of housing Outlet parallel to joists New or existing construction Mounting brackets flipped over and mounted to top of sides of housing Outlet parallel to joists New or existing construction WIRING OPTIONS WIRING PLATE POSITION VERTICAL POWER CABLE CONNECTION HORIZONTAL POWER CABLE CONNECTION Wiring plate mounts to side or top of housing
20. o 25 4 cm 22ZZ2IIII777777777777777777777277777777777 PS gt NZ NZA Raccordement de conduit typique un ventilateur converti en d charge droit angle UTILISATION ET ENTRETIEN Le ventilateur a t con u pour une utilisation continue Si d sir il peut tre command l aide d un interrupteur marche arr t ou d un r gulateur de vitesse semi conducteurs Suivre les instructions de c blage fournies avec le r gulateur et respecter tous les codes locaux et provinciaux en vigueur de m me que le Code national de l lectricit i AVERTISSEMENT Pour diminuer les risques de d charge lectrique d brancher la source d alimentation avant toute op ration d entretien Pour nettoyer la soufflerie Retirer la panneau d access d brancher la soufflerie du bo tier retirer les crous de fixation de la soufflerie et retirer d licatement la soufflerie du bo tier Utiliser un accessoire d aspirateur appropri ou retirer la grille et nettoyer l aide d un chiffon doux et de savon ou de d tergent doux pour nettoyer la zone de d charge de la soufflerie et la roue NE PAS LAISSER D EAU S INFILTRER DANS LE MOTEUR S assurer que la soufflerie est compl tement s che avant de la r installer Le moteur est lubrifi en permanence Ne pas lubrifier ou d monter le moteur BRSAN L400L re Page 12 PI CES DE RECHANGE PI CES DE RECHANGE L GENDENNDER F DESCRIPTION 97014744 Bo tier 97014728
21. riv prot ge GFCI interrupteur de circuit en cas de d faut de mise la terre du neutre Ne placez jamais un interrupteur dans un endroit o il peut tre rejoint d une baignoire ou d une douche 10 Cette unit doit tre mise la terre ATTENTION 1 2 Pour ventilation g n rale seulement Ne utilisez pas pour vacuer les vapeurs ou mat riaux dangereux ou que peuvent exploser Pour viter d endommager les coussinets du moteur et des tur bines bruyantes et ou mal quilibr es assurez que l unit motrice est exempte de poussi re provenant des murs en pierres s ches et la construction Sile ventilateur est install dans un endroit non conditionn tel qu un grenier Entourez le ventilateur d un isolant thermi que afin de r duire toute condensation ventuelle Veuillez lire l tiquette de sp cifications sur le produit pour d autres renseignements et exigences MOD LES L400L L500L L700L Page 9 TABLE DES MATIERES Ce manuel se divise comme suit e INSTALLATION TYPIQUE Cette section montre une installation standard dans un batiment en cours de construction ou d ja construit Montage construction en cours Montage construction termin e Cablage Installation des conduits d charge de soufflerie dans ligne e OPTIONS DE MONTAGE e OPTIONS DE C BLAGE Position de la plaque de c blage OPTIONS D INSTALLATION DES CONDUITS Positions de la
22. s los c digos y est ndares aplicables incluyendo c digos y est ndares de construcci n a prueba de incendios Se necesita suficiente aire para la combusti n y extracci n de gases por la chimenea del equipo que quema combustible para evitar la retrogresi n de las llamas Siga las directrices del fabricante y est ndares de seguridad como los publicados por la Asociaci n Nacional de Protecci n Contra Incendios o por sus siglas en ingl s NFPA y la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado o por sus sigles en ingl s ASHRAE y los c digos de las autoridades locales Cuando corte o taladre en una pared o cielo raso no da e cableado el ctrico o instalaciones no visibles Ventiladores con conductos siempre deben extraer hacia el exterior Para reducir el riesgo de incendio use s lo ductos de metal Si esta unidad va a instalarse sobre una ba era o ducha debe marc rsela como correcta para dicha aplicaci n y debe conectarse a un protegido GFCI Cortacicuito Accidental a Tierra Nunca instale un interruptor donde se pueda alcanzar desde una ba era o ducha 10 Esta unidad se debe conectar a tierra CUIDADO 1 2 Para uso de ventilaci n general solamente No lo use para extraer materiales o vapores peligrosos o explosivos Para evitar da o a los cojinetes del motor y h lices ruidosas y o desequilibradas mantenga la unidad de potencia lejos de
23. sion soit remise accidentellement Lorsque le verrouillage de la d connexion n est pas possible mettez bien en vue un signal d avertissementtelle qu une tiquette sur le panneau d alimentation L installation et la pose des fils lectriques doivent tre effectu es par une ou des personnes qualifi es conform ment tous les codes et normes applicables incluant les normes de construction en rapport aux incendies ll faut suffisamment d air pour une combustion appropri e et l chappement des gaz par le tuyau de la chemin e de l quipement br lant du combustible pour pr venir un contre cou rant Suivez les instructions du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et des autorit s du code local Lors de la coupe ou du per age dans un mur ou un plafond prenez soin de ne pas endommagerles fils lectriques etles autres utilit s dissimul es La d charge des ventilateurs conduit par vent doit toujours se faire l ext rieur Pour r duire le rsque d incendie utilisez seulement des donduits de ventilation en m tal Si cette unit doit tre install e au dessus d une baignoire ou d une douche elle doit tre marqu e comme tant appropri e pour l application et tre connect e un circuit d
24. t a notify Broan at the address stated below or telephone 1 800 637 1453 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date In the U S contact Broan NuTone LLC 926 West State Street Hartford WI U S A 53027 In Canada contact Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99042725F A e MODELOS BREAN L400L L500L L700L P gina 5 VENTILADORES LOSONE SELECT Para montaje en cielo raso pared 120 V LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIO GOLPE ELECTRICO O LESION A PERSONAS OBSERVE LO SIGUIENTE 1 9 Use esta unidad solamente de la manera indicada por el fabricante Si tiene preguntas p ngase en contacto con el fabricante a la direcci n o tel fono que aparecen en la garantia Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con algun tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente El trabajo de instalaci n y cableado el ctrico deben estar hechos por personal capacitado de acuerdo con todo
25. th the homeowner Homeowner Use and Care information on page 3 A e MODELS BRSAN L400L L500L L700L Page 2 TYPICAL INSTALLATION MOUNTING New Frame Construction 10 ROUND DUCT 4 X181 TO 10 ROUND TRANSITION Mounting brackets factory shipped in position for Ye ceiling material CEILING JOIST 24 centers 10 ROUND Blower factory shipped DUCT in horizontal discharge position 4 X 18 TO 10 ROUND MOUNTIN e TRANSITION SCREW Factory shipped unit installed in new construction MOUNTING Existing Frame Construction 4 X 18 TO 10 ROUND TRANSITION 2 X 4 FRAMING wide side down 4 X 1812 TO 10 ROUND TRANSITION 10 ROUND MOUNTING BRACKETS Attached to opposite sides of housing amp upside down so housing is flush with FINISHED CEILING MATERIAL CEILING JOIST 24 centers shown finished ceiling Factory shipped unit installed in existing construction TYPICAL INSTALLATION WIRING TOP BACK OF HOUSING GROUND TO WIRING PLATE WIRING 120 VAC LINE IN Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes DUCTING Straight through blower discharge NT ROOF CAP 472 X 18 2 TO 10 ROUND TRANSITION PASS SSI SSI SSII SSII SSII SSI SSII SSII SSI 10 ROUND Two ways to connect ductwork to a factory shipped unit NOTE Make sure the sh
26. vented to the outdoors To reduce the risk of fire use only metal ductwork If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit Never place a switch where it can be reached from a tub or shower 10 This unit must be grounded CAUTION A 1 2 For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit If ventilator is installed in an unconditioned space such as an attic Surround the ventilator with thermal insulation to mini mize possible condensation Please read specification label on product for further informa tion and requirements TABLE OF CONTENTS This manual is divided into sections as follows TYPICAL INSTALLATION This section shows a common installation in new and existing frame construction Mounting new construction Mounting existing construction Wiring Ducting straight through blower discharge MOUNTING OPTIONS WIRING OPTIONS Wiring Plate Position DUCTING OPTIONS Blower Discharge Positions Ducting right angle blower discharge USE AND CARE SERVICE PARTS WARRANTY Installer Leave this manual wi

Download Pdf Manuals

image

Related Search

Related Contents

  FREE! - K  Service Manual: Venus-C2/V-C2 (D014/D015  Sony SAL-16105 Operating Instructions    ENH210 User Manual - EnGenius Technologies, Inc.  Cremina owner`s book  table - Les Amis de Sceaux  Trevi DPH 2203  Intégration et Publication de logiciels sous licences Open  

Copyright © All rights reserved.
Failed to retrieve file