Home
Zephyr AK8200AS Ventilation Hood User Manual
Contents
1. Mounting Height amp Clearance DUCTING A minimum of 6 round or 3 1 4 x 10 rectangular duct must be used to maintain maximum air flow efficiency for single blower and 8 round duct for dual and remote blowers Always use rigid type metal ducts only Flexible ducts could restrict air flow by up to 50 Also use calculation on page 5 to compute total available duct run when using elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size If turns or transitions are required install as far away from hood duct output and as far apart between the two as possible www zephyronline com Minimum mount height between range top to hood bottom should be no less than 20 Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will lose its performance and efficiency If available also refer range manufacturer s height clearance requirements and recommended hood mounting height above range AK8200AS Vertical Ducting 8 round minimum dual blower Horizontal Ducting N A AK8300ASX Vertical Ducting 6 round minimum single blower 8 round minimum dual and remote blowers Hor
2. THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards Including fire rated construction b Sufficient air is needed for power combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always vent to the outdoors NEVER place a switch where it can be reached from a tub or shower Make sure the power is off before installing wiring or maintenancing pao WARNING TO REDUCE T
3. are not sure the range hood is properly grounded Do not have a fuse in the neutral or ground circuit National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire with ground Please also refer to Electrical Diagram on product AK8200AS 710W 5 95 Amps AK8300ASX CBI 290B CBI 600B 217W 1 85 Amps 460W 3 85 Amps AK8300ASX PBI 1100A PBN 1000A CBE 1000 780W 6 55 Amps 840W 7 3 Amps A cable locking connector not supplied might also be required by local codes Check with local requirements purchase and install appropriate connector if necessary FEDERAL COMMUNICATION COMMISSION INTERFACE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular insta
4. clip RF Remote control does not work Se MS oll Battery is dead Replace battery with type A23 12v N Poor communication with the power pack Remote control must be within 15 ft of power pack 3 RF remote lost communication with power pack Reset power pack and remote by switching power off at the circuit breaker for 5 minutes Pace remote on counter top near power pack and switch the circuit breaker back on DESCRIPTION Replacement Parts Light Bulb MR16 GU10 35W each Baffle Filter each Remote Control Optional Accessories Liner 36 AK8200AS Liner 42 AK8200AS Liner 48 AK8300ASX Liner 54 AK8300ASX Liner 60 AK8300ASX To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 PART Z0B 0023 50210010 14000005 AKO806AS AK0842AS AK0848AS AK0854AS AKO860AS List of Parts and Accessories y STAPLE YOUR RECEIPT HERE 2 EPA R Proof of the original purchase ee date is needed to obtain Limited Warranty service under warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS please call 1 888 880 8368 Zephyr Corporation referred to herein as we or us warrants to the original consumer purchaser referred to herein as you or your of Zephyr products the Products that such Products will be free from defects in materials or work manship as follows Ten
5. HE RISK OF FIRE USE ONLY METAL DUCTWORK NOT FOR USE OVER AN OUTDOOR GRILL CAUTION To reduce risk of fire and to properly exhaust air outside Do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages OPERATION Always leave safety grilles and filters in place Without these components operating blowers could catch onto hair fingers and loose clothing The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation maintenance and suitable use of the product The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance NOTE Please check www zephyronline com for revisions before doing any custom work ELECTRICAL REQUIREMENTS Important Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas pipe Check with a qualified electrician if you
6. Use Care and Installation Guide ESSENTIALS ZEPH R Tornado Il AK8200AS Tornado lll AK8300ASX www zephyronline com Model number Serial Number Date of Purchase Sales Dealer JUL11 0601 2010 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS www zephyronline com SAFETY NOTICE ciones ncn 2 3 LIST OF MATERIALS 4 4 INSTALLATION Ducting Calculation Sheet 5 Mounting Height amp Clearance 6 Ducting OptiONS lt ioe 7 NS PSCHICATIONS enne 8 Electrical rie dis 9 Installing the Power Pack 10 Single and Dual Internal Blowers 11 Remote Blower Preparation ocooiciicicic 12 FEATURES amp CONTROLS TOUCH CONtFOlS coania RF Remote Control MAINTENANCE Cleaning and Installing Filters 16 A ee ects 17 TROUBLESHOOTING cececseecseeeseessneesseeesneeesneesanees 18 LIST OF PARTS AND ACCESSORIES 19 Table of Contents Important Safety Notice sa oa0o READ AND SAVE THESE INSTRUCTIONS www zephyronline com WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE CONTROL DEVICE WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer if you have questions contact the manufacturer b Before servicing
7. Year Limited Warranty for Parts For ten years from the date of your original purchase of the Products we will provide free of charge Products or parts to replace those that failed due to manufacturing defects We may choose in our sole discretion to repair or replace parts before we elect to replace the Products One Year Limited Warranty for Labor For one year from the date of your original purchase of the Products we will provide free of charge the labor cost associated with repairing the Products or parts to replace those that failed due to manufacturing defects After the first year from the date of your original purchase you are responsible for all labor costs associated with this warranty Warranty Exclusions This warranty covers only repair or replacement at our option of defective Products or parts and does not cover any other costs related to the Products including but not limited to a normal maintenance and service required for the Products and consumable parts such as light bulbs metal and carbon filters and fuses b any Products or parts which have been subject to freight damage misuse negligence accident faulty installation or installa tion contrary to recommended installation instructions improper maintenance or repair other than by us c commer cial use of the Products or use otherwise inconsistent with its intended purpose d natural wear of the finish of the Prod ucts or wear caused by improper maintenance u
8. ay lt F gt flashes display from lt F gt to lt gt F CL FCC Caution To assure continued compliance any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral device This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This remote control may operate in humid environments but not when placed on a wet surface SYNCHRONIZATION To create a unique link between your range hood and remote control please follow the below steps 1 With range hood off press and hold the lights button on the range hood until the letter F shows on the display screen 2 Press the lights button on the remote the lights on the hood will turn on The synchronization is complete REMOTE CONTROL FEATURES The RF remote control is equipped with a magnet for easy storage The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder Maximum remote control communication distance from power pack is 15 feet Blower On Blower On Speed Selection 1 O Power Off O Blower On Speed Selection By pressing 77
9. e the capacitor The motor wire is not connected Make sure the motor wire is plugged into the molex connector working but the lights are not The light bulb is loose Tighten the light bulb The unit is 1 The motor is not secure in place 1 Tighten the motor in place vibrating 2 Damaged blower wheel 2 Change the blower 3 The hood is not secured in place 3 Check the installation of the hood The motor is 1 Defective halogen bulb 1 Change the halogen bulb 2 2 3 3 The wires on the control board are loose Make sure the wires on control board are connected properly The hood is not venting out properly 1 The hood might be hanging too high from the cook top Adjust the distance between the cook top and the bottom of the hood within 26 and 36 range 2 The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood Close all the windows and doors to eliminate the outside wind flow 3 Blockage in the duct opening or duct work Remove all the blocking from the duct work or duct opening Using the wrong size of ducting The direction of duct opening is against the wind Adjust the duct opening direction Change the ducting to correct size Filter is vibrating Filter is loose Adjust or change the filter Spring clip is broken inside filter opening Change the spring
10. eeded if using power pack with a dual internal or external blower ELECTRICAL WARNING All Electrical work must be performed by qualified electrician or person with similar technical know how and background For personal safety remove house fuse or open circuit breaker before beginning installation Do not use extension cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also be required by local codes Check with local requirements and codes purchase and install appropriate connector if necessary Cable Lock Installation Electrical Installation Installing the Power Pack A CAUTION At least two installers are required due to the weight and size of the hood 1 Install blower into Power Pack AK8200AS Blower is pre installed AK8300ASX Refer to page 11 for instructions Remove support screw from top of Power Pack before installing into cabinet FIG 2b Install 8 round adapter to top of Power Pack See page 11 step 3 for instuctions Install optional AKO8xxAS Stainless St
11. eel Liner Review manual included with liner for more details If no liner is used cut out an opening in the bottom of the cabinet by following the dimensions in FIG 1 Lift Power Pack into opening and secure to bottom of cabinet using 4 M4 stainless steel screws 1 in each corner see FIG 2 note Wood blocking may need to be added to cabinet base if additional support is needed Install duct work and seal with duct tape Install electrical Remove all packing materials before using Power Pack Switch power on and check for leaks around duct tape Install baffle filters www zephyronline com AK8200AS AK8300ASX 26 1 16 3411 16 C L C L 14 3 4 cabinet bottom cut out size FIG 1 minimum 3 4 wood base metal or other non combustible material 4 M4 ss wood screws 1 in each corner gt t OO o o o o FIG 2 esi support screw MULTIPLE BLOWERS ARE COMPATIBLE WITH AK8300ASX ONLY AK8200AS INCLUDES A 1000 CFM DUAL BLOWER ONLY FOR REMOTE BLOWER PREPARATION INSTRUCTIONS TURN TO PAGE 12 1 Position blower plate over bracket on inside 2 Connect 6 pin male connector from blower back of hood and pivot up Secure plate to hood wiring to 6 p
12. er soil use liquid degreaser After cleaning you may use non abrasive stainless steel polish cleaners to polish and buff out the stainless luster and grain Always scrub lightly using a micro fiber or clean cotton cloth and with the grain Baffle Filters The filters are intended to trap residue and grease from cooking Although the filters should never need replacing they are required to be cleaned every 30 days or more often depending on cooking habits Filters may be placed in dishwasher at low heat or soaked in hot soapy water Dry filters and re install before using hood Installing Baffle Filters FIG 4 1 Place filter into top groove of the power pack as shown and pull towards front of power pack using handles 2 Pivot back of filter upwards so it is angled in the power pack 3 Push filter into channel on back of power pack to lock into place Replacing Baffle Filters Hood Model Part No Qty to Order AK8200AS 50210010 2 FIG 4 AK8300ASX 50210010 3 REPLACING LIGHT BULBS CAUTION Light bulb becomes extremely hot when turned on DO NOT touch bulb until switched off and cooled Touching hot bulbs could cause serious burns Make sure all power is turned off and bulbs are not hot Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suct
13. ficiency If improperly maintained residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components and possible clog duct work and create a fire hazard a Features amp Controls Touch Controls Features amp Controls Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit a set if baffle filters are fitted by the factory These baffle filters are intended to filter out residue from cooking They need not be replaced on a regular basis but are required to be kept clean The filter clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent prior to cleaning Baffle Filter Clean Indicator When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting Function Reset the filter clean reminder timer when filters are cleaned and re installed with hood off Press and hold for approximately 5 seconds the display will appear hold for approximately 5 seconds until F _ on display disappears _ The filter clean reminder function is now reset and a new 30 hours elapse cycle is initiated Clean Filters hold 5 sec displ
14. in female connector in the power with 2 10x3 16 screws blower pictured is a pack plug is located inside the power pack PBI 1100A protruding from the white control board box 3 Single Blower Connect 6 round duct work to blower collar Dual Blower Place 8 round adapter on top of power pack and secure with 4 M4x8 screws Connect 8 round duct work to 8 round adapter Installation Single and Dual Internal Blowers Installation Remote Blower Preparation www zephyronline com Place 8 round adapter on top of power pack 2 Install threaded end of remote blower wiring and secure with 4 M4x8 screws Connect 8 through external blower wiring knock out B round duct work to 8 round adapter located in junction box on top of power pack Place cap over threaded end of remote blower 4 Connect 6 pin male connector from blower wiring and secure by turning clockwise wiring to 6 pin female connector in the power pack plug is located inside the power pack protruding from the white control board box CBE 1000 PBN 1000A WIRING DIAGRAM A Ground wire screw 2 92 3 location inside WoO Remote Blower a Black high E Wiring Box Z Blue med Junction Box gt Remote Blower hood 4 Red low Ll Green ground Secure green ground wire from remote blower wiring to ground screw located inside the power pack NOTE For instructions on installing remote blowers please refe
15. ion cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type MR16 GU 10 35W halogen For Zephyr part numbers please turn to page 19 of the manual Bottom View Maintenance Lights O Troubleshootin www zephyronline com TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III What to do Issue Cause After installation the unit doesn t work 1 The power source is not turned ON il Make sure the circuit breaker and the unit s power is ON The power line and the cable locking connector is not connecting properly Check the power connection with the unit is connected properly The switch board and control board wirings are disconnected Make sure the wirings between the switch board and control board are connected properly The wires on control board are loose The switch board or control board is defective Make sure the wires on the control board are connected properly Change the switch board or control board Light works but motor is not turning The motor is defective possible seized Change the motor The thermally protected system detects if the motor is too hot to operate and shuts the motor down The motor will function properly after the thermally protected system cool down Damaged capacitor Chang
16. izontal Ducting N A WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal ductwork only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Some Ducting Options n f a A a E Cl AMS E c A O l side wall cap T side wall cap w gravity damper w gravity damper 6 Y Soffit or crawl space Roof Pitch w Flashing 8 Cap www zephyronline com Y ce O wo f 5 2 te Q oe i IEEE Q 25 15 16 j o Y 29 13 16 2 AK8200AS AK8200AS Se front top O YU amp lt Y S o 2 5 8 E 14 11 16 15 13 16 AK8200AS AK8300ASX 33 1 8 14 3 4 D T 3 4 dl i can E e y EN e 7 2 5 8 34 5 8 A elec B ext k o blower 38 7 16 k o AK8300ASX AK8300ASX front top note 8 round transition is only n
17. llation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help a Important Safety Notice List of Materials MODELS AK8200AS AND AK8300ASX PARTS SUPPLIED AK8200AS 1 Power Pack 2 Baffle filters 2 Halogen light bulbs pre installed 1 Dual internal blower pre installed 1 8 round adapter 1 RF remote control with battery 1 Hardware package HARDWARE PACKAGE CONTENTS Suction Cup 1 AK8300ASX 1 Power Pack 3 Baffle filters 4 Halogen light bulbs pre installed 1 8 round adapter 1 Remote blower wiring harness 1 RF remote control with battery 1 Hardware package NO BLOWER EEE A M4 x 8 4 DO PARTS NOT SUPPLIED Ducting conduit and all installation tools Th m fl Cable connector if required by local codes Single internal blower kit CB 290B CBI 600B AK8300ASX only Dual internal blower kit PB 1100A AK8300ASX only External blower kit CBE 1000 AK8300ASX onl
18. ons or exclusions may not apply to you To the extent that applicable law prohibits the exclu sion of implied warranties the duration of any applicable implied warranty is limited to the same ten year period described above Any oral or written description of the Products is for the sole purpose of identifying the Products and shall not be construed as an express warranty Prior to using implementing or permitting use of the Products you shall determine the suitability of the Products for the intended use and you shall assume all risk and liability whatsoever in connection with such determination We reserve the right to use functionally equivalent refurbished or reconditioned parts or Products as warranty replacements or as part of warranty service This warranty is not transferable from the original purchaser and applies in the United States and Canada To Obtain Service Under Limited Warranty To qualify for warranty service you must a notify us at the address or telephone number stated below within 60 days of the discovery of the defect b give the model number and part identifi cation number and serial number and c describe the nature of any defect in the Product or part At the time of the request for warranty service you must present evidence of your proof of purchase and proof of the original purchase date If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documenta tion to obtain se
19. or cleaning unit switch power off at service panel and lock panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Take care when using cleaning agents or detergents Suitable for use in household cooking area WARNING TO REDUCE THE RISK OF RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when flaming food Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element Keep fan filters and grease laden surfaces clean Use high setting on hood only when necessary Don t leave hood unattended when cooking Always use cookware and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL
20. r to the CBE 1000 or PBN 1000A manuals included in the blower packaging and on our website www zephyronline com 2 O ial On Dim Off 5 Display Speed level Delay Off Indicator i 3 0 T O 5 Min Delay Off Blower On Off Adjust 3 Speed Levels Blower On Off By pressing D the blower is switched On and Off When switched on the blower turns on at the same speed it was switched off at When switched off the entire hood powers off including the lights Speed Selection The 3 speed levels are selected by pressing O to decrease and to increase speed level The display indicates speed level selected Pressing when the hood is off will also turn it on Delay Off This is used for programmed shut down of blower and lights 5 minutes after the function is activated Press once a dot displays in the lower right hand side of display indicating the function is on The hood will change to speed 1 and shut down after 5 minutes Lights On Dim Off Switch lights On by pressing once again to dim and again to switch Off Display Displays blower speed level delay off status and filter clean replace notification Baffle Filter Clean Reminder After every 30 hours of use the display will start flashing an reminding you to clean the baffle filters from residue and possible clogs The standard baffle filters are required to be cleaned frequently and as recommended in order to maintain blower ef
21. rvice you will be responsible for all shipping travel labor and other costs related to the services Please check our website for any revisions www zephyronline com Zephyr Corporation Service Department 2277 Harbor Bay Parkway Alameda CA 94502 1 888 880 8368 JUNO8 0101
22. se of corrosive and abrasive cleaning products pads and oven cleaner products e chips dents or cracks caused by abuse or misuse of the Products f service trips to your home to teach you how to use the Products or g damage to the Products caused by accident fire floods or act of God If you are outside our service area additional charges may apply for shipping costs for warranty repair at our designated service locations and for the travel cost to have a service technician come to your home to repair remove or reinstall the Prod ucts After the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WE HEREBY DISCLAIM AND EXCLUDE ALL OTHER EXPRESS WARRAN TIES FOR THE PRODUCTS AND DISCLAIM AND EXCLUDE ALL WARRANTIES IMPLIED BY LAW INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states or provinces do not allow limitations on the duration of an implied warranty or the exclusion or limitation of incidental or consequential dam ages so the above limitati
23. the blower is switched On Press 77 again to cycle through all three blower speeds Blowers On Hood Off By pressing D the blowers will power on at the last speed setting Press y again and the entire hood will power off including lights O Delay Off By pressing the blower and lights will enter Delay Off mode A dot will appear in the lower right corner of the power pack display 3 indicating the function is on The blower will change to speed 1 and shut down after 5 minutes Lights On Dim Off Switch lights On by pressing E once again to dim and again to switch Off 5 Min Delay Off 3 O Lights On Dim Off Features amp Controls RF Remote Control REMOTE CONTROL MAINTENANCE Clean the remote control using non abrasive detergents Follow instructions below for replacing battery Using a small flat head screwdriver raise the cover of the battery door A in order to access the battery compartment Remove the battery and replace with Type A23 12V Negative end of battery should face the spring inside the remote Replace battery door and recycle old battery 2 Maintenance Cleaning and Installing Filters www zephyronline com SURFACE MAINTENANCE Clean periodically with hot soapy water and clean cotton cloth Do not use corrosive or abrasive detergent or steel wool scoring pads which will scratch and damage surface Do not use products containing chlorine bleach or orange cleaners For heavi
24. y In Line blower kit PBN 1000A AK8300ASX only Optional stainless steel hood liner AKO8xxAS 3 www zephyronline com Duct pieces Equivalent number length xused 3 1 4 x 10 Rect straight 1 Ft x 6 Round straight 7 10 Round straight 3 1 4 x 10 Rect 90 elbow 3 1 4 x 10 Rect 45 elbow 3 1 4 x 10 Rect 90 flat elbow 3 1 4 x 10 Rect wall cap with damper 3 1 4 x 10 Rect to 6 round transition Duct pieces 6 Round wall cap with damper Equivalent number length xused 6 Round roof cap 6 roundto 3 1 4 x 10 rect transition 6 round to 3 1 4 x 10 rect transition 90 elbow 7 10 Round 90 elbow 7 10 Round 45 elbow 7 10 Round wall cap with damper 7 10 Round roof cap 3 1 4 x 10 Rect to 6 round transition 90 elbow 6 Round 90 elbow 6 Round 45 elbow Subtotal column 1 7 round to 3 1 4 x 10 rect transition Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 5 7 round to 3 1 4 x 10 rect transition 90 elbow Subtotal column 2 Subtotal column 1 Total ductwork Installation Ducting Calculation Sheet Installation
Download Pdf Manuals
Related Search
Related Contents
Samsung RC-S200 User Manual to Open Manual File - American Musical Supply Tripp Lite SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, SNMP, Webcard pre-installed, 2U Rack/Tower, USB, DB9 Serial Echo X7503202102 User's Manual ADSL2+ Modem Router DM111PSPv2 User Manual User Manual - Flixcar.com Copyright © All rights reserved.
Failed to retrieve file