1. Remove the red cap from the gas pipe Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing is used be certain there are no kinks Turn the shutoff valve in the gas supply line to the open position manual shutoff rigid gas supply line Use a brush and liquid detergent to test all external gas connections for leaks Bubbles around connections will indicate a leak lf a leak appears shut off gas valve controls and tighten connections Then check connections again 10 E Exhaust dryer Using a 4 inch clamp connect exhaust vent to exhaust outlet in dryer If connecting to existing exhaust vent make sure the vent is clean The dryer exhaust vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure exhaust vent is secured to exhaust hood with a 4 inch clamp Move dryer into final position Do not crush or kink exhaust vent Make sure dryer is level F Check operation Check that you Y did not skip any steps Y installed all parts Y properly installed dryer legs Y leveled dryer Y have secured all exhaust vent joints with 4 clamps Y have all the tools you started with Plug power supply cord into grounded outlet Turn power supply on Read the Use and Care Guide to fully understand your new dryer Select a full heat cycle not the air cycle and start dryer After fi
2. e Tubo de 1 27 cm 1 2 pulg tipo IPS con una combinaci n de accesorios para tubos e Conexi n recomendada a la secadora Tubo met lico nuevo y flexible con dise o certificado por la A G A Asociaci n Americana de Gas o CSA Accesorio abocinado O de 0 95 cm 38de QD pulg x rosca hembra NPT de 0 95 cm 3 8 de pulg Conexi n opcional a la secadora El tubo de la l nea de suministro de gas debe tener los siguientes requisitos e Para longitudes menores de 6 1 m 20 pies se pueden utilizar tubos de 0 95 cm 3 8 de pulg si lo permiten los c digos y la compa a de gas e Para longitudes mayores de 6 1 m 20 pies se deben utilizar tubos m s largos Conversi n a gas licuado propano l quido L P La conversi n la debe hacer un t cnico calificado Un t cnico de servicio calificado es una persona con experiencia y que ha recibido la debida capacitaci n en mantenimiento y reparaci n de equipos de gas y que est familiarizada con las precauciones necesarias Para el n mero del conjunto de conversi n de gas vea la base del quemador de la llave del gas Sistema de salida de aire 44 ADVERTENCIA Vj Peligro de incendio Utilice un conducto metalico pesado No utilice conducto plastico No utilice un conducto de lamina metalica No seguir estas instrucciones puede ocasionar la muerte o un incendio Se debe utilizar un conducto de salida de aire met lico y pesad
3. extendido 8 8 m 29 pies 5 2 m 17 pies 6 4 m 21 pies 4 6 m 15 pies La longitud m xima del sistema de salida de aire depende de e el tipo de conducto utilizado metal r gido o flexible el n mero de codos utilizados si la salida de aire es por el costado o por la parte inferior La salida de aire por el costado o por la parte inferior agrega un ngulo de 90 dentro de la secadora Para determinar la m xima longitud de la salida de aire agregue un ngulo de 90 en la tabla Vea la tabla de longitudes de conductos de salida de aire que corresponda a su tipo de campana para determinar las longitudes m ximas de conductos que puede utilizar No utilice conductos m s largos que los especificados en las tablas de longitudes de conductos de salida de aire Los sistemas de salida de aire m s largos de lo especificado Acumulan pelusas creando peligro potencial de incendio Reducen la vida til de la secadora Reducen el funcionamiento lo que produce tiempos de secado m s prolongados y aumenta el consumo de energ a 2 Determine el n mero de codos que necesitar 3 En la columna en la que se indica el tipo de conducto de metal que est utilizando r gido o flexible busque la longitud m xima de conducto de metal en la misma l nea del n mero de codos 4 Determine el n mero requerido de abrazaderas para conductos de di metro de 10 2 cm 4 pulg La longitud m
4. Installation Instructions IMPORTANT Read and save these instructions Installer Leave Installation Instructions with homeowner Homeowner Keep Installation Instructions for future reference For best performance install dryer according to Installation Instructions Failure to complete installation as instructed could void warranty Save Installation Instructions for local inspector s use Part No 8535841 Gas Dryer Set to operate on NATURAL GAS Have questions about your dryer Call your dealer or local authorized service company When you call you will need the dryer model number and serial number Both numbers are on the model serial rating plate located in the door well behind the dryer door and on front of opening Record the numbers here for handy reference Model No Serial No Before you begin Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean ADANGER You can be killed or seriously injured if you don t immediately follow instructions A WARNING You can be killed or seriously injured if y
5. gt a 27 Dimensions shown with feet extended 1 from bottom of dryer Most installations will require at least 5 clearance behind the dryer for the dryer vent Recessed area installed in a recessed area or closet installation using dimensions shown e Dimensions are in inches and are the minimum allowable Detailed space Front view requirements can also be found on the label on the back panel of the Yo dryer These requirements ensure 15 minimum clearances to combustible construction and prevent blockage of air into the combustion chamber e Additional spacing should be considered for ease of installation and servicing Companion appliance ae 4 Wek 07 lt gt f 0 spacing should also be considered Wall door and floor molding may require additional spacing Installation clearances No other fuel burning appliance Use recommended clearance for may be installed in the same closet easier installation or recessed area e If codes permit dryer may be Recommended minimum Back Sides Top Fo 5 0 1 0 18 15 50 1 0 18 15 11 A A 14 1 8 2 7 1 4 Exhaust dimensions back exhaust O OOO o bottom exhaust 4 A A A ER eft or ri g ht S i d e du a le saa val A A 14 1 8 se 10 1 4 Closet confined area installa
6. Failure to do so could result in back or other injury Remove tape from G dryer cabinet Open dryer door and remove tape from dryer drum Not all dryer drums are taped Remove drying j rack if included Turn dryer drum counterclockwise to make sure all tape was removed Wipe drum with damp cloth to remove any dust Take two cardboard corners from dryer carton and place them on floor in back of dryer Firmly grasp body of dryer and gently lay it on its back on the cardboard corners diamond 4 marking Start to screw legs into holes by hand Use an adjustable wrench or 1 hex head socket wrench to finish turning legs until you reach the ridge with the diamond marking Stand dryer up on cardboard or hardboard C Level dryer Dryer must be level to reduce noise and assure proper performance Slide dryer onto cardboard or hardboard before moving across floor to prevent floor damage Move dryer close to its permanent location Leave enough room to connect exhaust vent Remove cardboard or hardboard from under dryer Check levelness of dryer by placing a level on top of dryer first side to side then front to back If dryer is not level adjust dryer legs up or down If legs are not long enough to level dryer order Extended Dryer Feet Kit Part No 279810 sold two legs per kit from your dealer D Make gas connection ME C
7. Seleccione un ciclo de calor completo no el ciclo de aire y ponga en marcha la secadora Despu s de cinco minutos abra la puerta de la secadora Debe sentir calor dentro de la secadora Si el quemador no se incendi y usted no siente calor dentro de la secadora apague la secadora durante 5 minutos Luego verifique Y que todos los controles est n en la posici n de ON encendido Y que el bot n de start puesta er marcha ha sido oprimido con firmeza Y que est abierta la llave de cierre de la l nea de suministro de gas Repita la prueba de los 5 minutos Si la secadora sigue sin funcionar debidamente verifique si Y el suministro el ctrico est conectado Y los fusibles de la instalaci n el ctrica de su casa est n intactos y bien ajustados y que no se haya disparado ning n disyuntor Y la puerta de la secadora est cerrada Si la secadora hace ruido inusual verifique si est nivelada Dura Safe Conjunto de salida de aire SURE CONNECT Los conjuntos facilitan la instalacion 9 Proporciona un espacio de 114 mm 4 1 2 pulg entre la secadora y la pared Accesorios de cierre de resorte 9 La longitud total del conjunto es de 2 44 m 8 pies 4 Se puede incluir un conducto adicional entre las secciones para recorridos m s largos El Conjunto contiene 2 secciones de conducto de 1 22 m 4 pies con codos cerrados adheridos 1 placa de pared para instala
8. la secadora su distribuidor tiene disponibles los siguientes conjuntos Conjunto de salida de aire No 279818 blanco Conjunto de salida de aire No 279819 almendra Conjunto de salida de aire No 279925 biscuit Conjunto de salida de aire No 279969 plateado flujo de aire de salida bien N mejor N Seleccione la ruta que proporcione la v a m s recta y directa hacia el exterior Planifique la instalaci n de forma que utilice el menor n mero de codos y ngulos Evite hacer ngulos de 90 Deje el maximo espacio posible cuando utilice codos o forme angulos Doble el conducto gradualmente para no retorcerlo Determine la longitud del conducto Preferido Cuando usted tiene una campana de salida de aire de 10 2 cm 4 pulg Longitud maxima del conducto met lico de 10 2 cm 4 pulg de di metro N mero Flexible de completamente codos de 90 extendido O 19 5 m 64 pies 11 0 m 36 pies 2 13 4 m 44 pies 8 2 m 27 pies 3 110 7 m 35pies 7 6 m 25 pies 4 8 2m 27 pies 7 0 m 23 pies Aceptable lt 6 4 cm 2 1 2 pulg Cuando usted tiene una campana de salida de aire de 6 4 cm 2 1 2 pulg Longitud m xima del conducto met lico de 10 2 cm 4 pulg de di metro N mero R gido Flexible de codos de 90 completamente O 17 7 m 58 pies 8 5 m 28 pies 114 6 m 48 pies 7 0 m 23 pies 2 11 6 m 38 pies 5 8 m 19 pies SS E A
9. n Ponerse en contacto con un instalador calificado para asegurarse de que las instalaciones el ctricas y de gas cumplan con todos los c digos y reglamentos nacionales y locales Que la secadora tenga salida de aire al exterior La secadora debe tener salida de aire al exterior para evitar la exposici n a substancias perjudiciales en los combustibles del gas evitar que se acumulen grandes cantidades de pelusas y humedad y para mantener la eficiencia en el Para el debido funcionamiento de la secadora El lugar debe proporcionar e Protecci n contra la intemperie y el agua no guarde ni utilice la secadora en un lugar donde estar a expuesta al agua y a la intemperie e Temperatura ambiental superior a los 7 C 45 F Si la temperatura es inferior a los 7 C 45 F los ciclos autom ticos podr an no detenerse e Piso nivelado La inclinaci n m xima debajo de toda la secadora no debe ser mayor de 2 5 cm 1 pulgada Si la inclinaci n es mayor de 2 5 cm 1 pulgada instale el Conjunto de Extensi n de Patas para Secadora Parte No 279810 Si la secadora no est nivelada la ropa podr a no girar debidamente y los ciclos de detecci n autom tica podr an no funcionar correctamente e Piso resistente para resistir el peso de la secadora de 79 4 kg 175 libras secado Esta instalaci n debe cumplir con los c digos locales o si no existen c digos locales en los EE UU con los c digos de instalaci
10. n C digo Nacional de Combustible de Gas ANSI Z223 1 NFPA 54 Se pueden obtener copias de las normas mencionadas poni ndose en contacto con CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Herramientas que se necesitan para la instalacion e Nivel e Guantes e Llave ajustable que se abra 2 5 cm 1 pulg o llave tubular hexagonal de 2 5 cm 1 pulg e Desarmador de punta plana e Destornillador Phillips 2 e Gafas protectoras e Tijeras de hojalatero para instalaciones con nueva salida de aire e Pistola para calafateo y masilla de calafatear e Cuchilla para masilla e Llave de tubos de 20 3 cm 8 pulg 25 4 cm 10 pulg e Compuesto para juntas de tubo resistente al gas licuado propano l quido L P e alicates Piezas suministradas para la instalaci n Saque el paquete de piezas del tambor de la secadora Verifique que se hayan incluido las quatro patas niveladoras 4 patas niveladoras Piezas necesarias para la instalaci n Antes de adquirir piezas consulte los c digos locales y con la compa a de gas y lea los requisitos el ctricos de gas y de salida de aire en las p ginas de la 5 a la 8 Gas La l nea de suministro de gas debe tener e Conexi n intermedia NTP de 3 1 mm 1 8 de pulg e Una llave de cierre manual dentro de una distancia de 183 cm 6 pies del aparato electrodom stico La l nea r gida de suministro de gas debe tener
11. necesite Modelo No Serie No Antes de empezar Su seguridad y la seguridad de los demas son muy importantes Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodom stico Lea y obedezca siempre todos los mensajes de seguridad Este es el s mbolo de alerta de seguridad Este s mbolo le alerta sobre los peligros potenciales que podr an causarle la muerte o herirle a usted o a otras personas Todos los mensajes de seguridad seguir n al s mbolo de alerta de seguridad y a la palabra PELIGRO o ADVERTENCIA Estas palabras significan APELIGRO Podr a morir o sufrir graves lesiones si no sigue inmediatamente las instrucciones 4h ADVERTENCIA Podr a morir o sufrir graves lesiones si no sigue las instrucciones Todos los mensajes de seguridad le indicar n cu l es el peligro potencial le indicar n c mo reducir las posibilidades de lesionarse y le dir n qu podr a ocurrir si no se siguen las instrucciones ADVERTENCIA Para su seguridad se debe seguir la informaci n contenida en este manual para minimizar el riesgo de incendio o explosi n o prevenir da os a la propiedad lesiones personales o la muerte No almacene ni utilice gasolina u otros l quidos y vapores inflamables cerca de este o cualquier otro aparato electrodom stico QU HACER SI HAY OLOR A GAS e No intente encender ning n aparato electrodom stico e No to
12. no existen c digos locales aplicables con el C digo Nacional de Electricidad ANSI NFPA 70 INSTRUCCIONES DE PUESTA A TIERRA Este aparato electrodom stico debe estar conectado a tierra En caso de mal funcionamiento o falla la puesta a tierra reducir el riesgo de choque el ctrico al proporcionar una trayectoria de menos resistencia para la corriente el ctrica tomacorriente de puesta a tierra con 3 terminales enchufe tripolar de conexi n a LA tierra cord n el ctrico terminal de conexi n a tierra La terminal del cord n el ctrico debe conectarse en un tomacorriente adecuado que haya sido debidamente instalado y puesto a tierra de acuerdo con todos los c digos y reglamentos locales ADVERTENCIA La conexi n indebida del conductor a tierra para el material puede producir riesgo de choque el ctrico Verifique con un electricista calificado o t cnico de servicio mantenimiento y reparaciones si tiene dudas sobre si la secadora ha sido debidamente puesta a tierra No modifique el enchufe provisto con la secadora Si no calza en el tomacorriente haga que un electricista calificado instale un tomacorriente adecuado Se pueden obtener copias de las normas mencionadas anteriormente de National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 Suministro de gas ADVERTENCIA Peligro de explosi n Utilice una l nea de suministro de gas nueva aprobada
13. por la A G A Asociaci n Americana de Gas o CSA Instale una llave de cierre Ajuste con firmeza todas las conexiones del gas Si utiliza gas licuado propano liquido L P para esta secadora haga que una persona calificada compruebe que la presi n del gas no sobrepase los 33 cm 13 pulg de columna de agua Entre las personas calificadas se cuentan los miembros del personal de calefacci n con licencia personal autorizado de compa a de gas y personal de servicio mantenimiento y reparaciones autorizado No seguir estas instrucciones puede ocasionar la muerte una explosi n o un incendio OBSERVE TODOS LOS C DIGOS Y REGLAMENTOS APLICABLES Requisitos de gas Verifique que la secadora est equipada con el quemador correcto para el tipo de gas de su domicilio La informaci n del quemador se encuentra en la placa de modelo serie en la cavidad de la puerta de la secadora Si esta informaci n no corresponde al tipo de gas disponible dir jase al distribuidor donde compr su secadora Gas natural Esta secadora esta equipada para ser utilizada con GAS NATURAL Su diseno esta certificado por la CSA Internacional para gases licuados propano o butano con la adaptaci n adecuada Gas licuado propano l quido L P No debe intentar adaptar la secadora para utilizarla con otro gas que no sea el especificado en la placa de modelo serie sin consultar con la compa a de gas La adapta
14. r gido o flexible Utilice abrazaderas para conductos para sellar todas las juntas No utilice para asegurar el conducto cinta adhesiva para conductos tornillos ni otros dispositivos de sujeci n que se extiendan hacia el interior del conducto Revisi n de servicio La presi n posterior en cualquier sistema de salida de aire utilizado no debe ser mayor de 1 5 cm 0 6 pulg de columna de agua medida con un man metro inclinado en el punto donde el conducto de salida de aire se conecta con la secadora 30 5 cm 12 pulg m nimo Requisitos de instalaci n en una casa m vil o rodante Si los c digos lo permiten esta secadora puede instalarse en una casa m vil o rodante La instalaci n de la secadora debe cumplir con los requisitos del U S Manufactured Home Construction and Safety Standard Norma de construcci n y seguridad de casas manufacturadas T tulo 24 CFR Parte 3280 anteriormente Federal Standard for Mobile Homes Construction and Safety T tulo 24 HUD Parte 280 ltima edici n La secadora debe fijarse al piso Pida a su distribuidor el Conjunto para instalaci n en casa m vil o rodante Parte No 346764 El conjunto incluye los elementos de fijaci n necesarios e instrucciones de instalaci n detalladas Tambi n puede solicitar a su distribuidor los elementos met licos del sistema de salida de aire Se deben hacer disposiciones especiales para la introducci n del aire del exterior en l
15. the particular type of gas in your new home Burner information is specified on the model serial rating plate Periscopes For Offset OT Sa SEEN Provides 2 1 2 clearance between dryer and wall Great for closet installations 0 18 18 29 or 29 50 periscopes include one male snap lock fitting one extra long draw band collar and one clamp 0 18 18 29 29 50 Part 4396037 Part 4396011 Part 4396014 0 18 Periscope Use when vent outlets y a J overlap or are offset Part 4396037 Excess length can be trimmed to fit 18 29 and 29 50 Periscope Sections separate fittings can face Swivel collar same or opposite wall connection Telescoping sections Swivel collar Extra long band clamp for dryer connection Beveled edges allow corner AS installations SN 18 29 Part 4396011 29 50 Part 4396014 For more information or to have your venting professionally installed call the Consumer Assistance Center Check your Use and Care Guide for a toll free number to call or call the dealer from whom you purchased this appliance The dealer is listed in the Yellow Pages of your phone directory under Appliances Household Major Service and Repair Tape lint collector lid to cabinet Shut off electrical supply to dryer Unplug power E supply cord and tape it Sx securely to dryer Shut off gas supply valve in the gas supply line Disco
16. to prevent crushing and kinking Flexible metal vent must be fully extended and supported when the dryer is in its final position Remove excess flexible vent to avoid sagging and kinking that may result in reduced air flow An exhaust hood should cap the exhaust vent to prevent rodents and insects from entering the home Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust Such as flowers rocks or bushes etc If using an existing exhaust system clean lint from entire length of system and make sure exhaust hood is not plugged with lint Replace any vinyl or metallized plastic foil vent with rigid metal or flexible metal vent Use clamps to seal all joints Do Not use duct tape screws or other fastening devices that extend into the interior of the vent to secure vent Service check Back pressure in any exhaust system used must not exceed 0 6 inches in water column measured with an incline manometer at the point that exhaust vent connects to dryer Mobile home installation requirements If codes permit this dryer is suitable for mobile home installations The installation of the dryer must conform to the U S Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Homes Construction and Safety Title 24 HUD Part 280 latest edition The dryer must be fastened to the floor
17. xima utilizando un conducto rectangular de 5 1 cm x 15 2 cm 2 pulg x 6 pulg con 2 codos y una campana exterior de salida de aire de 6 4 cm 2 1 2 pulg es 2 4 m 8 pies Para los sistemas de salida de aire no incluidos en las tablas de longitudes tales como sistemas de conexiones para unidades m ltiples plenos o ventiladores con aporte de energ a exterior consulte el Manual de Servicio Parte No 603197 Para comprar el Manual de Servicio busque el n mero para llamar gratis en su Manual de uso y cuidado h Etapas de la instalacion Si esta instalando una lavadora y una secadora instale la secadora primero A Instale el sistema de salida de aire P ngase gafas protectoras y guantes Instale la campana exterior de salida de aire Use masilla de calafatear para sellar la abertura de la pared exterior alrededor de la campana de salida de aire Conecte el conducto de salida de aire a la campana El conducto de salida de aire DEBE calzar dentro de la campana Asegure el conducto a la campana con una abrazadera de 10 2 cm 4 pulg Dirija el conducto de salida de aire hasta donde est la secadora Utilice la v a m s recta posible Evite formar ngulos de 90 Utilice abrazaderas para sellar todas las juntas Podr a necesitar tijeras de hojalatero para cortar el conducto a la longitud requerida B Prepare la secadora 4 ADVERTENCIA Peligro de peso excesivo Se necesit
18. 000 feet elevation contact your serving gas supplier Supply line requirements Provide a 1 2 inch IPS rigid gas supply line to the dryer location An individual manual shutoff valve must be installed within 6 feet of the dryer in accordance with the National Fuel Gas Code ANSI 2223 1 latest edition shutoff valve open position to dryer rigid gas supply line Recommended gas line connection method If local codes permit it is recommended that new flexible metal tubing design certified by AGA or CSA be used for connecting the appliance to the rigid gas supply line The gas pipe which extends through the lower rear of the appliance has 3 8 inch male pipe thread Optional gas line connection method When acceptable to the gas supplier and local codes 3 8 inch approved tubing may be used for lengths under 20 feet For lengths over 20 feet larger tubing should be used A combination of pipe fittings must be used to connect the dryer to the gas line Pipe joint compounds resistant to the action of L P gas must be used An elbow and connector between tubing and dryer pipe may be needed to prevent kinking A 1 8 inch NPT plugged tapping accessible for test gauge connection must be installed immediately upstream of the gas supply connection to the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in ex
19. A 70 GROUNDING INSTRUCTIONS This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current The power supply cord plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances 3 prong ground type outlet 3 prong ground plug ZA Power supply cord Ground prong WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Copies of the standards listed may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 Gas supply A WARNING Explosion Hazard Use a new AGA or CSA approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or
20. OO 333S PORO OOOO Si se instala una puerta para el closet se requieren aberturas m nimas no obstruidas para asegurar que haya flujo adecuado de aire Son aceptables las puertas de persiana con aberturas para el aire equivalentes Espacios de la instalaci n Utilice los espacios recomendados para facilitar la instalaci n Requisitos el ctricos 44 ADVERTENCIA 4 Peligro de choque el ctrica Enchufe la secadora en un tomacorriente puesto a tierra con 3 terminales No quite el terminal de conexi n a tierra No use un adaptador No use un cord n de extensi n No seguir estas instrucciones puede ocasionar la muerte un incendio o un choque el ctrico Si los c digos lo permiten y se utiliza un alambre de puesta a tierra separado se recomienda que un electricista calificado determine si la trayectoria de la puesta a tierra es adecuada Importante Observe todos los c digos y reglamentos aplicables Se requiere un suministro el ctrico de 120 voltios 60Hz con fusibles s lo de CA de ace 15 20 amperios Se recomienda un fusible de retardo o un disyuntor Se debe proveer un circuito separado que sea usado para este aparato electrodom stico solamente Dentro de la consola o dentro del panel delantero inferior se encuentra un diagrama del cableado M todo recomendado de puesta a tierra Esta secadora al ser instalada debe ponerse a tierra de acuerdo con los c digos locales o si
21. Order Mobile Home Installation Kit Part No 346764 from your dealer Kit includes the necessary fastening hardware and detailed installation instructions Metal exhaust system is also available through your dealer Special provisions must be made for the introduction of outside air into the dryer when installed in a mobile home The area of any opening for the introduction of outside air such as a nearby window should be at least twice as large as the dryer exhaust opening outside Ny wall floor enclosed area skirting The dryer must be exhausted outside The exhaust vent must be securely fastened to a non combustible portion of the mobile home structure and must not terminate beneath the mobile home Plan the exhaust vent installation Typical installations exhaust from the rear of the dryer Route the vent The exhaust outlet is located at the center of the rear of the dryer The exhaust vent can be routed up down left right or straight out the back of the dryer See Recessed area closet installation section Page 4 for space requirements This dryer may be converted to exhaust out the right or left side or through the bottom Typical installations for left or right side exhausting Typical installations for bottom exhausting To convert the dryer the following kits are available from your dealer Exhaust Kit No 279818
22. a de suministro de gas Fije con cinta adhesiva el extremo del tubo de suministro de gas 6 Gire las patas niveladoras totalmente hacia adentro Deslice la secadora sobre un Nw pedazo de cart n o madera dura antes de moverla por el piso para no da ar el acabado de este 11 Pieza No 8535841 2002 Whirlpool Corporation Benton Harbor Michigan 49022 U S A Impreso en los EE UU
23. a secadora cuando se instala en una casa m vil o rodante El rea de cualquier abertura para la introducci n de aire del exterior como una ventana cercana debe tener al menos el doble del tama o de la abertura de salida de aire de la secadora Pared Ny exterior Piso rea encerrada Zocalillo La secadora tiene que tener salida de aire al exterior El conducto de salida de aire debe fijarse con seguridad a una parte no combustible de la estructura de la casa m vil o rodante y no debe terminar debajo de la casa m vil o rodante Planifique la instalacion del conducto de salida de aire En las instalaciones usuales la salida de aire se realiza por la parte posterior de la secadora Recto Dirija el conducto El orificio de salida de aire se encuentra al centro de la parte posterior de la secadora El conducto de salida de aire puede dirigirse hacia arriba hacia abajo hacia la izquierda hacia la derecha o recto fuera de la parte posterior de la secadora Para requisitos de espacio vea la secci n de Instalaci n en rea empotrada closet armario en la p gina 4 La secadora puede adaptarse para tener salida de aire por el costado derecho o izquierdo o a trav s de la parte inferior Instalaciones usuales para salida de aire por la parte inferior Instalaciones usuales para salida de aire por el costado izquierdo o derecho Para adaptar
24. above 45 F If room temperature is below 45 F automatic cycles may not shut off e Level floor Maximum slope under entire dryer should not be more than 1 inch If slope is greater than 1 inch install Extended Dryer Feet Kit Part No 279810 Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level Sturdy floor to support dryer weight of 175 pounds It is your responsibility to e Observe all governing codes and ordinances e Check code requirements Some codes limit or do not permit installation of clothes dryers in garages closets mobile homes or sleeping quarters Contact your local building inspector e Comply with the installation specifications and dimensions e Consider spacing requirements for companion appliances e Properly install dryer e Check that you have everything necessary for proper installation e Contact a qualified installer to insure that the electrical and gas installation meets all national and local codes and ordinances e Exhaust to outdoors Dryer must be exhausted outdoors to prevent exposure to harmful substances in the gas fuels to prevent large amounts of lint and moisture from accumulating and to maintain drying efficiency This installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 installation codes Copies of the standards listed may be o
25. an dos o m s personas para mover e instalar la secadora No seguir esta instrucci n puede ocasionar una lesi n en la espalda u otra lesi n Quite la cinta JE adhesiva del gt gabinete de la AL secadora Abra la puerta de la secadora y quite la lt cinta adhesiva del tambor de la j secadora No todos los tambores de secadora tienen cinta adhesiva Saque la rejilla de secado si est incluida Gire el tambor de la secadora en sentido contrario a las manecillas del reloj para asegurarse de que quit todas las cintas Limpie el tambor con un pa o h medo para eliminar el polvo Tome dos ngulos de cart n de la caja de la secadora y col quelos en el piso detr s de la secadora Sujete con firmeza la secadora y apoye con cuidado su parte posterior sobre los ngulos de cart n marca de rombo Comience a atornillar las patas en los orificios manualmente Utilice una llave ajustable o una llave tubular de 2 5 cm 1 pulgada para terminar de darles vueltas a las patas hasta llegar a la estr a con la marca de rombo Coloque la secadora en posici n vertical sobre un pedazo de cart n o madera dura C Nivelaci n de la secadora La secadora debe estar nivelada para reducir el ruido y asegurar su debido funcionamiento Deslice la secadora sobre un pedazo de cart n o madera dura antes de moverla por el piso para no da ar el piso Mu
26. btained from CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Tools needed for installation level e gloves e adjustable wrench that opens to 1 or 1 hex head socket wrench e flat blade screwdriver 2 Phillips head screwdriver e safety glasses e tin snipes new vent installation e caulking gun and compound e putty knife e 8 or 10 pipe wrench e pipe joint compound resistant to L P gas e pliers Parts supplied for installation Remove parts package from dryer drum Check that all 4 legs were included 4 leveling legs Parts needed for installation Check local codes and with gas supplier and read electrical gas and venting requirements Pages 5 8 before purchasing parts Gas Gas supply line must have e 1 8 NPT plugged tapping e Shutoff valve within 6 feet of appliance is required Rigid gas supply line must be e 1 2 IPS pipe used with a combination of pipe fittings e Recommended connection to dryer New flexible metal tubing design certified by AGA or CSA 918 fare x 918 NPT Emp female Y 7 Optional connection to dryer Gas supply line tubing must be e Lengths under 6 1 m 20 feet can use 3 8 approved tubing if codes and gas supplier permit e Lengths over 6 1 m 20 feet should use larger tubing L P gas conversion Conversion must be made by a qualified technician A qualified service technician is someone e
27. cess of 1 2 psi The dryer must be isolated from the gas supply piping system by closing the equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi Copies of the standards listed may be obtained from CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Exhaust requirements amp WARNING Vy Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire e Do Not use non metal flexible vent or exhaust hoods with magnetic latches e Do Not exhaust dryer into any gas vent chimney furnace cold air vent wall ceiling concealed space of a building attic or crawl space or any other vent used for venting e Do Not install flexible vent in enclosed walls ceilings or floors Important Observe all governing codes and ordinances Exhaust your dryer to the outside Moisture and lint indoors may cause e Lint to gather around the dryer where it can be fuel for a fire e Moisture damage to woodwork furniture paint wallpaper carpet etc e Housecleaning problems and health problems Dura Safe venting products are recommended and are available from your dealer Four inch diameter vent must be used Use a heavy metal vent Do Not use plastic or metal foil vent Rigid metal vent is recommended
28. ci n debe efectuarla un t cnico de servicio mantenimiento y reparaciones calificado Los n meros de piezas del conjunto de adaptaci n de gas se indican en la base del quemador de la llave de gas Requisitos de entrada del quemador Altitudes de hasta 3048 m 10 000 pies El dise o de esta secadora ha sido certificado por la CSA Internacional para uso en altitudes de hasta 3048 m 10 000 pies sobre el nivel del mar a la capacidad B T U Unidades T rmicas Brit nicas indicada en la placa de modelo serie No se requieren ajustes de la entrada del quemador cuando se utiliza la secadora hasta esa altitud Altitudes superiores a los 3048 m 10 000 pies Al instalarla a una altitud superior a los 3048 m 10 000 pies es necesario reducir la capacidad B T U del quemador indicada en la placa de modelo serie un cuatro por ciento 4 por cada incremento de 3048 m 1 000 pies de la altitud Dir jase a la compa a de gas de su localidad cuando necesite asistencia para adaptar la secadora a otros tipos de gas y o instalarla a una altitud superior a los 3048 m 10 000 pies Requisitos de la l nea de suministro Proporcione una l nea r gida de suministro de gas de 1 27 cm 1 2 pulgada al lugar donde se encuentre la secadora Se debe instalar un llave de cierre manual individual dentro de una distancia de 1 8 m 6 pies de acuerdo con el C digo Nacional de Combustible de Gas ANSI Z223 ltima edici n
29. ciones en espacios estrechos 2 abrazaderas de 102 mm 4 pulg Parte No 4396028 Tan f cil como contar 1 2 3 Secadora Secadora Una con Extienda el abrazadera un codo secci n de conducto a la pared y otro a la secadora Desde la parte conducto hacia superior una arriba casi hasta las dos la parte superior de secciones de la secadora luego conducto empuje la secadora en la pared Dura Safe y Sure Connect son marcas de f brica de Whirlpool USA Va a trasladar de lugar la secadora Verifique con su compa a de gas O distribuidor de gas si su secadora est equipada con el quemador correcto para el tipo particular de gas en su nuevo hogar La informaci n sobre el quemador est especificada en la en la placa de modelo serie Periscopios para instalaciones acodadas e instalaciones estrechas 9 Proporciona un espacio de 64 mm 2 1 2 pulg entre la secadora y la pared 9 Ideales para instalaciones en un closet armario 9 Los periscopios de 0 45 7 cm 0 18 pulg 45 7 73 7 cm 18 29 pulg o 73 7 127 cm A 29 50 pulg incluyen un E i accesorio macho de cierre de 1873 No 4396037 resorte un collar de banda de 49 7 cm 73 7 cm 18 29 pulg ae Pieza No 4396011 tracci n extragrande y una 73 7 127 em 29 50 pulg abrazadera Pieza No 4396014 Periscopio de 0 45 7 cm 0 18 pulg 9 Utilicelo cuando las bocas M de salida se solapan o est n eD acodadas i 3 4 El
30. cm gt 1 1 2 pulg abertura de la l nea de gas gt a 68 6 cm 27 pulg La puerta de la secadora se extiende 35 6 cm 14 pulgadas desde el frente de la secadora cuando se abre totalmente 35 6 cm 14 pulg i 1 We A eg hee ee es ty l e 1 slo 15 9 cm 6 1 4 pulg gt Dimensiones mostradas con patas extendidas 25 4 mm 1 pulgada desde la parte inferior de la secadora La mayor a de las instalaciones requerir n al menos un espacio de 12 7 cm 5 pulg detr s de la secadora para el conducto de salida de aire de la secadora Instalaci n empotrada Vista de frente 0 pulg gt lt lt 0 pulg Puede necesitarse m s espacio para molduras de paredes suelos o puertas No se debe instalar ning n otro aparato que queme combustible en el mismo closet armario o rea empotrada e Si los c digos lo permiten esta secadora puede instalarse en un rea empotrada o en un closet armario utilizando las dimensiones que se indican e Las dimensiones est n en cent metros y pulgadas y son las m nimas permisibles Tambi n se pueden ver los requisitos de espacio detallados en la etiqueta que est en el panel posterior de la secadora Estos requisitos aseguran los espacios m nimos para materias combustibles y evitan el bloqueo del aire hacia la c mara de combusti n Se debe considerar espacio adicional para facilitar la instalaci
31. combustible para un incendio e La humedad da e maderas muebles pintura papel de empapelar alfombras etc Surjan problemas de limpieza y problemas de salud Se recomiendan productos de salida de aire Dura Safe los cuales puede adquirir de su distribuidor Se debe utilizar un conducto de di metro de 10 2 cm 4 pulg Utilice conducto met lico pesado No utilice conductos pl sticos o de l mina met lica Se recomienda utilizar un conducto met lico r gido para evitar aplastamientos o enroscamientos El conducto met lico flexible debe estar totalmente extendido y apoyado cuando la secadora est en su posici n definitiva Elimine el conducto flexible sobrante para evitar que cuelgue o se retuerza lo que puede reducir el flujo del aire Una campana exterior de salida de aire debe tapar el coducto de salida de aire para evitar que los roedores y los insectos se introduzcan en la casa La campana exterior de salida de aire debe estar al menos a 30 5 cm 12 pulg del suelo o cualquier objeto que pueda interponerse en la v a de salida de aire como flores rocas o arbustos etc Si utiliza un sistema de salida de aire existente limpie las pelusas a lo largo de todo el sistema de salida de aire y aseg rese de que la campana exterior de salida de aire no est tapada con pelusas Reemplace cualquier conducto de salida de aire de vinilo o de l mina pl stica metalizada con un conducto de metal
32. e la secadora debe calzar sobre el orificio de salida de aire de la secadora y dentro de la campana exterior de l nea r gida de salida de aire suministro de gas Aseg rese de que el conducto de salida de aire est fijado a la campana exterior de salida de aire con una abrazadera de 10 2 cm 4 pulg Gire la llave de cierre en la l nea de suministro de gas hasta la posici n abierta Utilice un cepillo y un detergente l quido para verificar si hay fugas en las conexiones externas del gas Las burbujas alrededor de las conexiones indican que hay fugas Si advierte una fuga cierre los controles de la llave del gas y ajuste las conexiones Luego vuelva a revisar las conexiones Mueva la secadora a su posici n definitiva No aplaste ni enrosque el conducto de salida de aire Aseg rese de que la secadora est nivelada 10 F Verifique el funcionamiento Aseg rese si Y no omiti alg n paso de la instalaci n Y instal todas las piezas Y instal debidamente las patas de la secadora Y la secadora est nivelada Y se asegur todas las conexiones del conducto de salida de aire con abrazaderas de 10 2 cm 4 pulg Y tiene todas las herramientas con las que comenz Enchufe el cord n el ctrico en el tomacorriente de puesta a tierra Encienda el suministro de energ a el ctrica Lea completamente el Manual de uso y cuidado para que comprenda el funcionamiento de su nueva secadora
33. eba de presi n del sistema a presiones de prueba superiores a 1 2 Ibs pulg La secadora se debe aislar del sistema de tuber a de suministro de gas cerrando la llave de cierre del equipo durante cualquier prueba de presi n de dicho sistema a presiones de prueba iguales o inferiores a 1 2 Ibs pulg Se pueden obtener copias de las normas mencionadas poni ndose en contacto con CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Requisitos del sistema de salida de aire 44 ADVERTENCIA Vy Peligro de incendio Utilice un conducto metalico pesado No utilice conducto plastico No utilice un conducto de lamina metalica No seguir estas instrucciones puede ocasionar la muerte o un incendio No utilice un conducto flexible no met lico ni campanas exteriores de salida de aire con cierres magn ticos e No coloque la salida de aire de la secadora en ning n conducto de gas chimenea horno conducto de aire fr o pared cielo raso espacio cerrado de un edificio un tico o s tano de peque a altura ni en ning n conducto de ventilaci n No instale un conducto flexible en paredes cielos rasos o pisos encerrados Importante Observe todos los c digos y reglamentos aplicables Realice la salida de aire de la secadora a exteriores La humedad y las pelusas a interiores pueden hacer que e Las pelusas se acumulen alrededor de la secadora donde se pueden convertir en
34. eva la secadora cerca de su lugar permanente Deje suficiente espacio para conectar el conducto de salida de aire Quite el pedazo de cart n o madera dura que est debajo de la secadora Verifique si la secadora est nivelada colocando un nivel sobre la secadora primero de lado a lado luego de adelante para atr s Si la secadora no est nivelada ajuste las patas de la secadora hacia arriba o hacia abajo hasta que est nivelada Si las patas no son lo suficientemente largas para nivelar la secadora pida a su distribuidor el Conjunto de extensi n de patas para secadora Parte No 279810 se venden dos patas por conjunto D Conexion del gas E Salida de aire de la secadora gt Abrazadera gt de 10 2 cm 4 pulg Abrazadera de 10 2 cm 4 pulg Quite el casquete rojo que est en el tubo de gas Conecte el suministro de gas a la secadora Utilice un compuesto para juntas resistente a la acci n del gas licuado propano l quido L P para las conexiones de gas Si emplea tubos flexibles met licos aseg rese de que no tengan partes retorcidas Utilizando una abrazadera de 10 2 cm 4 pulg conecte el conducto de salida de aire en el orificio de salida de aire de la secadora Si est haciendo la conexi n en un conducto de salida de aire existente aseg rese llave de cierre en de que el conducto est limpio posici n abierta El conducto de salida de aire d
35. exceso de longitud puede recortarse Parte No 4396037 Periscopios de 45 7 73 7 cm 18 29 pulg y 73 7 127 cm 29 50 pulg Secciones separadas los accesorios pueden orientarse en el mismo sentido o en sentidos opuestas Collar giratorio conexi n en la pared Secciones de extensi n Collar giratorio Abrazadera de banda extragrande para conectar a la secadora Bordes biselados permiten la instalaci n en PS rincones Ny 45 7 73 7 cm 18 29 pulg Parte No 4396011 73 7 127 cm 29 50 pulg Parte No 4396014 Para m s informaci n o para que su sistema de salida de aire sea instalado profesionalmente llame al Centro de Asistencia al Consumidor Consulte en su Manual de uso y cuidado para el n mero para llamar gratis o llame al distribuidor del que compr este aparato electrodom stico El distribuidor aparece en las P ginas Amarillas de su gu a telef nica bajo Aparatos electrodom sticos Caseros Grandes Mantenimiento y Reparaciones Fije con cinta la tapa del filtro de pelusas en el gabinete Desconecte el suministro de energ a a la secadora Desenchufe el cord n Fije con cinta la parte superior en el gabinete UA el ctrico y fijelo con A pn ems a la secadora Fije con cinta la puerta en el panel delantero Cierre la llave de suministro de gas en la tuberia de suministro de gas Desconecte los accesorios para el gas de la secadora y tape la tuberi
36. fire OBSERVE ALL GOVERNING CODES AND ORDINANCES Gas requirements Check that dryer is equipped with the correct burner for the particular type of gas in the home Burner information will be found on the model serial rating plate in door well of the dryer If this information does not agree with the type of gas available see your dealer Natural Gas This dryer is equipped for use with NATURAL GAS It is design certified by CSA International for L P propane or butane gases with appropriate conversion L P Gas No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service technician Gas conversion kit part numbers are listed on the gas valve burner base Burner input requirements Elevations up to 10 000 feet The design of this dryer has been certified by CSA International for use at altitudes up to 10 000 feet above sea level at the B T U rating indicated on the model serial rating plate Burner input adjustments are not required when the dryer is operated up to this elevation Elevations above 10 000 feet When installed above 10 000 feet a four percent 4 reduction of the burner B T U rating shown on the model serial rating plate is required for each 1 000 foot increase in elevation For assistance installing dryer above 10
37. llave de cierre en posici n abierta l nea r gida de suministro de gas M todo recomendado para la conexi n de la l nea de gas Si los c digos locales lo permiten se recomienda usar tubos met licos flexibles nuevos con dise o certificado por la A G A o CSA para conectar el electrodom stico a la l nea r gida de suministro de gas El tubo de gas que se extiende a trav s de la parte posterior inferior del electrodom stico tiene una rosca macho para tubos de 0 95 cm 3 8 de pulg M todo opcional de conexi n de la l nea de gas Cuando sea aceptable para la compa a de gas y los c digos locales se puede usar un tubo aprobado de 0 95 cm 3 8 de pulg para longitudes de menos de 6 m 20 pies Para longitudes de m s de 6 m 20 pies se deben utilizar tubos m s largos Se debe utilizar una combinaci n de accesorios para tubos para conectar la secadora a la l nea de gas Se deben utilizar compuestos para juntas de tubo resistentes a la acci n del gas licuado propano l quido L P Podr a necesitarse un codo y un conector entre la tuber a y el tubo de la secadora para evitar enroscamientos Se debe instalar una conexi n intermedia NPT de 0 3 cm 1 8 de pulgada accesible para la uni n de un medidor de prueba inmediatamente arriba de la conexi n de suministro de gas de la secadora La secadora se debe desconectar del sistema de tuber a de suministro de gas durante cualquier pru
38. n y el servicio reparaciones y mantenimiento Tambi n se deben considerar los requisitos de espacio para artefactos que se instalen al lado de la secadora Espacios de la instalaci n Utilice los espacios recomendados para facilitar la instalaci n Recomendados m nimos Parte Parte Parte posterior Costados superior delantera Empotrada 12 7 cm 0 cm 2 9 cm 0 cm 45 cm 38 1 cm 5 pulg 0 pulg 1 pulg 0 pulg 18 pulg 15 pulg Closet 12 7 cm 0 cm 2 9 cm 0 cm 45 cm 38 1 cm 2 5 cm 2 5 cm 5 pulg 0 pulg 1 pulg 0 pulg 18 pulg 15 pulg 1 pulg 1 pulg 4 Dimensions de la salida de aire salida por el costado salida por atr s saa p derecho o izquierdo O ooo ES A Ml 10 6 cm 5 4 pulg pul sv aaa tol nial 14 1 8 25 6 cm ae 10 1 4 pulg PT salida por la parte inferior 18 1 cm ova pulg 35 9 cm e Ms ea lt A 14 1 8 pulg gt Instalaci n en un closet armario o rea confinada Vista de frente Vista lateral 310 cm Puerta del closet armario 48 pulg el espaciamiento 12 7 cm 5 pulg es recomendado 0 cm es el m nimo 155 cm A gt lt 2 5 cm 24 pulg 1 pulg Aberturas minimas para el aire en la parte superior e inferior de la puerta del closet Se requiere el espacio recomendado para un codo de salida de aire externo OO
39. nnect gas fittings from dryer and cap gas supply line Tape end of dryer gas pipe Slide dryer onto cardboard or o hardboard before moving it across the floor to prevent damaging floor covering Tape top to cabinet Tape door to front panel Turn leveling legs all the way in 11 Part No 8535841 2002 Whirlpool Corporation Benton Harbor Michigan 49022 U S A Printed in U S A Instrucciones de instalacion IMPORTANTE Lea y conserve estas Instrucciones Instalador Deje las instrucciones de instalaci n con el propietario Propietario Guarde las instrucciones de instalaci n para referencia futura Para un mejor funcionamiento instale la secadora de acuerdo con las instrucciones de instalaci n No completar la instalaci n de acuerdo con las instrucciones podr a anular la garant a Conserve las instrucciones de instalaci n para uso del inspector de instalaciones el ctricas local Parte No 8535841 Secadora a gas Para funcionar con GAS NATURAL Tiene preguntas sobre su secadora Llame a su distribuidor o a la compa a de servicios autorizada de su localidad Cuando llame necesitar el n mero del modelo y el n mero de serie de la secadora Ambos n meros est n en la placa de modelo serie la cual se encuentra en la cavidad de la puerta detr s de la puerta de la secadora y al frente de la abertura Anote todos los n meros aqu para tenerlos a mano cuando los
40. o de 102 mm 4 pulgadas y abrazaderas Se recomiendan productos de salida de aire Dura Safe Puede adquirir productos de salida de aire Dura Safe de su distribuidor o llamando a Whirlpool Parts amp Accesories al n mero 1 800 442 9991 de lunes a viernes de 8 a m a 9 p m Hora Central est ndar s bado de 9 a m a 4 30 p m HCE Visite nuestro sitio en Internet en la direcci n http vwww whirlpoolappliances com accessories Para mas informacion vea la pagina 11 Campana exterior de salida de aire Preferible Lo Aceptable gt lt 6 4 cm 2 1 2 pulg A 10 2 cm 4 pulg No utilice campanas exteriores de salida de aire con cierres magn ticos Las instalaciones en casas m viles o rodantes requieren e Conjunto de instalaci n en casas rodantes Parte N mero 346764 e Elementos met licos del sistema de salida de aire Suelos con inclinaciones mayores de 2 5 cm 1 pulg Requieren Conjunto de extensi n de patas para secadoras Parte No 279810 Disponible para compra de su distribuidor Dimensiones de la secadora Se requiere de un tomacorriente puesto a tierra dentro de una distancia de 137 2 cm 4 1 2 pies para el 27 9 cm pagers ie 11 pulg cordon el ctrico 109 5 cm 74 3 cm 29 1 4 pulg modelos con manija de la puerta con montaje embutido 76 8 cm 30 1 4 pulg modelos con manija extendida de puerta eS 38
41. ou don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Clear the room building or area of all occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier A amp A WARNING Explosion Hazard Keep flammable materials and vapors such as gasoline away from dryer Place dryer at least 18 inches above the floor for a garage installation Failure to do so can result in death explosion or fire For proper drying performance The location must provide e Protection from weather and water Do not store or use dryer where it will be exposed to water and weather e Room temperature
42. que ning n interruptor el ctrico no utilice ning n tel fono en el edificio e Haga salir a las personas de la habitaci n edificio o rea e Llame inmediatamente a la compa a de gas desde el tel fono de un vecino Siga las instrucciones de la compa a de gas e Si no puede comunicarse con la compa a de gas llame al departamento de bomberos La instalaci n y el mantenimiento debe realizarlos un instalador calificado una agencia de servicio o la compa a de gas 44 ADVERTENCIA Peligro de explosi n Mantenga los materiales y vapores inflamables como la gasolina alejados de la secadora Para instalar la secadora en un garaje coloque la secadora al menos a 45 7 cm 18 pulg sobre el piso No seguir estas instrucciones puede ocasionar la muerte una explosi n o un incendio Es su responsabilidad e Observar todos los c digos y reglamentos aplicables e Verificar los requisitos del c digo Algunos c digos limitan o no permiten la instalaci n de las secadoras de ropa en garajes closets armarios casas m viles o rodantes o en dormitorios P ngase en contacto con el inspector de edificaciones de su localidad Cumplir con las especificaciones y dimensiones de instalaci n e Tomar en cuenta los requisitos de espacio para artefactos que se instalen al lado de la secadora Instalar debidamente la secadora Asegurarse de que tiene todo lo necesario para la debida instalaci
43. tion Front view Side view closet door a8 sain Oy i f spacing gt 5 is recommended 0 is minimum Minimum top and bottom air openings for closet door External exhaust elbow requires recommended spacing If a closet door is installed The minimum unobstructed air openings are required Louvered doors with equivalent air openings are acceptable Installation clearances Use recommended clearance for easier installation Electrical requirements amp WARNING y Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Important Observe all governing codes and ordinances A 120 volt 60 Hz AC only 15 or 20 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended A separate circuit serving only this appliance must be provided A wiring diagram is located inside the console or on the inside of the lower front panel Recommended ground method The dryer when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFP
44. ve minutes open dryer door You should feel heat inside dryer If the burner did not ignite and you do not feel heat inside the dryer shut the dryer off for 5 minutes Then check that Y controls are set in a running or On position Y start button has been pushed firmly Y gas supply line shutoff valve is open Repeat 5 minute test If dryer still does not operate properly check the following Y electrical supply is connected Y house fuse is intact and tight or circuit breaker has not tripped Y dryer door is closed If dryer makes an unusual noise check that dryer is level Dura Safe SURE CONNECT Vent Kit Kits Make Installation Easy 9 Provides 4 1 2 clearance between dryer and wall 4 Snap Lock fittings 4 Total kit length 8 feet Additional vent can be snapped between sections for Part 4396028 longer runs Kit Contains 2 4 vent sections with attached close elbows 1 Wall plate for close clearance installations 2 4 clamps As easy as 1 2 3 Wall Dryer Dryer Step 2 Extend vent upward almost to top of dryer then push dryer to wall Step 1 Clamp one elbow vent section to wall and one to dryer From over the top snap vent together Dura Safe and Sure Connect are Trademarks of Whirlpool U S A Moving dryer to a new location Check with your gas supplier or dealer to confirm that your dryer is equipped with the correct burner for
45. white Exhaust Kit No 279819 almond Exhaust Kit No 279925 biscuit Exhaust Kit No 279969 silver exhaust air The maximum length of the exhaust flow 7 system depends upon _ dia the type of vent rigid or flexible metal e the number of elbows used e side or bottom exhaust Side or bottom exhaust adds a 90 turn inside the dryer To determine maximum exhaust length add one 90 turn to the chart N Select the route that will provide the straightest and most direct path outdoors Plan the installation to use the fewest number of elbows and turns Avoid making 90 turns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking 1 See the exhaust vent length chart that matches your type hood for the maximum vent lengths you can use Do not use vent runs longer than specified in exhaust vent length charts Exhaust systems longer than specified will accumulate lint creating a potential fire hazard Determine vent length shorten the life of the dryer reduce performance resulting in g longer drying times and 4 increased energy usage 2 Determine the number of elbows you will need 3 In the column listing the type of metal vent you are using rigid or flexible find the maximum length of metal vent on the same line as the number of elbows 4 Determine the number of 4 inch diameter vent clamps required The ma
46. ximum length using a 2 x 6 rectangular vent with 2 elbows and a 2 1 2 exhaust hood is 8 feet For exhaust systems not covered by exhaust vent length charts such as multiple unit hookups plenums and power assist fans see Service Manual Part No 603197 To purchase the Service Manual see your Use and Care Guide for a toll free telephone number Preferred s AY When you have a 4 hood Maximum length of 4 diameter metal vent Number of Flexible 90 elbows fully extended 0 eater Aa test 31 feet 2 aatect 27t Acceptable 2 1 2 When you have a 2 1 2 hood Maximum length of 4 diameter metal vent Number of Flexible 90 elbows fully extended 58 feet 28 feet 48feet 23 fect 29feet_ 17 feet o a a 2 aste E A A 2tteet Steet Installation steps If installing washer and dryer install dryer first A Install vent system Put on safety glasses and gloves Install exhaust hood Use caulking compound to seal exterior wall opening around exhaust hood Connect exhaust vent to hood Exhaust vent MUST fit inside hood Secure vent to hood with 4 inch clamp Run exhaust vent to dryer location Use the straightest path possible Avoid 90 turns Use clamps to seal all joints Tin snips may be needed to cut vent to required length B Prepare the dryer A WARNING Excessive Weight Hazard Use two or more people to move and install dryer
47. xperienced and trained in servicing gas equipment and familiar with necessary precautions See gas valve burner base for gas conversion kit part number Venting system A WARNING Vy Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to do so can result in death or fire Four inch heavy metal exhaust vent and clamps must be used Dura Safe vent products are recommended Dura Safe vent products can be purchased from your dealer or by calling Whirlpool Parts amp Accessories 1 800 442 9991 Mon Fri 8am to 9pm CST Sat 9am to 4 30pm CST Visit our internet site at http www whirlpoolappliances com accessories See Page 11 for more information Exhaust hood Do Not use exhaust hoods with magnetic latches Preferred Acceptable Mobile home installations require e Mobile Home Installation Kit Part Number 346764 e Metal exhaust system hardware Floors sloped greater than 1 inch Require Extended Dryer Feet Kit Part No 279810 Available for purchase from your dealer A grounded electrical outlet is required within 4 1 2 feet for the lt 11 3 i power supply cord The dryer door extends 14 from the front of the dryer when fully opened 43 1 8 gas line opening sabe pes ee Se ieee sl 29 1 4 models with flush mounted door handle 30 1 4 models with extended door handle