1. Use amp Care Guide an Installation Instructions Ea lt WHIRLPOOL SA UNDERCOUNTER Ta p l WATER FILTRATION SYSTEMS Il amp Il een Water Filtration System Parts Remove parts from packages Check that you have all the parts filtration assembly System A filtration assembly System II B filtration assembly System III C filtration assembly cover D 2 mounting screws E Va blue tubing F Va orange tubing G 2 way grey connector with push in ends H saddle valve assembly I insert J plastic sleeve K brass compression nut L literature package Some state and local plumbing codes prohibit the use of saddle type valves The use of saddle type valves is prohibited in Alaska Delaware Idaho Kentucky Massachusetts Michigan Minnesota New Hampshire North Dakota Ohio Oregon and South Dakota Check your local plumbing codes for details Massachusetts CMR 248 strictly prohibits the use of saddle type valves The feed water connection must conform to applicable plumbing codes Tools Needed for Installation flathead screwdriver phillips screwdriver bucket or towel rounde electric drill or hand drill 346 drill bit y2 wrench Materials Needed for Basement Installation e step ladder e Additional tubing e 14 drill bit Part No 4319151 available e safety glasses from your Whirlpool dealer Materials Needed for Optional Sink Faucet Installation
2. L a i tubing Part No 4319151 from your Whirlpool dealer DO NOT use filtration system if water is micro biologically unsafe or water quality is unknown j i r HOOK UP WATER a Turn off cold water supply Turn on faucet to drain water from line e Connect saddle valve to cold water supply Turn saddle valve handle clockwise until piercing lance enters pipe and stops a Connect one end of orange tubing to saddle valve Connect other end to filtration assembly Water Filtration Systems Il amp Ill SYSTEM CONNECTION e Decide if the system will be connected to your refrigerator to an optional faucet or to both le Connect refrigerator s water supply to filtration assembly with blue tubing e Or install faucet in sink and connect blue tubing to filtration assembly e Or use T grey connector to connect both refrigerator and faucet ae P a smog TT k a i 2 GS o ah eI nstructions see following page go Instructions At A Glance For detailed i WARNING Electrical Shock Hazard Special care must be taken when drilling into water pipes Some water may remain in water supply pipe If an electric drill is used it must be properly grounded to prevent severe or lethal shock if water should enter driil e Use only an electric drill that is double insulated or properly grounded e Check with qualified electrician i
3. screw large U side or 388 O D A f inst soft pipe installation cooper ipe for he to 46 O D pipe installation 1 Assemble saddle valve on copper pipe Saddle valve must be on top side of horizontal pipe or side of vertical pipe to keep sediment from collecting in its valve If you are connecting the saddle valve to 38 O D copper pipe assemble bracket with small U side against copper pipe to prevent distortion of pipe If you are connecting the saddle valve to 7 6 to 58 O D pipe assemble bracket with large U side against copper pipe 1 Tighten bottom screw firmly DO NOT e overtighten copper pipe could be crushed 1 Have a towel ready in case of leakage Turn a saddle valve handle clockwise until the lance pierces soft copper pipe and then stops Do not continue to turn the saddle valve handle after it has stopped because you may pierce through the opposite side of pipe The saddle valve is now in the closed position 1 Turn on cold water supply to check for a leaks In case of leaks use an adjustable wrench to tighten nut below valve s handle Turn cold water back off and proceed to step 1k 1 Connect saddle valve to cold water supply a rigid metal or plastic pipe Use a grounded electric drill or a hand drill to drill 34s hole in top side of horizontal pipe or side of vertical pipe This will keep sediment from collecting in valve Turn saddle valve handle clockwise to expose
4. Once yoar or Water has off taste every 500 gals or odor Maintenance of this water filtration system is very important Replace the Sediment S Lead Reduction L and Carbon Filter CF cartridges annually Failure to maintain this water filtration system over an extended period of time could present health risks 10 Replacing filter cartridges 1 Turn off water supply at either saddle valve or main shut off Press refrigerator water dispenser to empty water into a container If using the optional sink faucet turn on faucet to drain any water in system Discard this water Wait five minutes for filtration assembly to depressurize 2 Lift cover off filtration assem bly Rotate cartridge one quarter slot turn to the left to remove connector tabs from receptacle Gently pull down to remove cartridge 3 Check that label on new cartridge matches label above cartridge recep tacle Remove red cap from o ring cartridge Wet O ring seals Di seals tabs of new cartridge with a little water Line up the tabs at the top of the new cartridge with the slots in the filtration assembly s receptacle Push cartridge up and turn it Va turn to the right to lock it into place Cartridge label must face front Pull down on cartridge to make sure it s receptacle cartridge firmly in place Repeat step if cartridge disconnects 4 Turn water supply back on and check for leaks Open faucet
5. AC Fine Test Dust 3Test requirement is 4 6 micrometer size particles per mL of influent These contaminants are not necessarily in your water supply Performance may vary based on local water conditions STest requirement 0 15 mg L 15 Particulate Performance Data Sheet Systems Il amp Ill This product has been tested and listed by NSF International under Standard 42 NSF for Taste Odor and Chlorine reduction Class I and Particulate reduction Class II and under Standard 53 for Cyst Turbidity Lead and VOC reduction Whirlpool Water Filtration System Ill SPECIFICATIONS Lead VOC and Taste Odor Chlorine reduction Class I CAPACITY 500 Gallons SERVICE FLOW RATE 0 6 GPM 2 2 L min 60 psi nn Performance influent Effluent Reduction Requirement Ds Ei o minimum75 Chlorine 2 0 mg L lt 0 1 mg L reduction Class l Particulate 560 000 part mL 18 000 part mL 98 minim m 85 reduction Class ll 1 i 3 4 L 99 994 minimum 99 9 Cyst 215 000 4 6 u mL2 390 4 6 p m 99 9 edicion APPLICATION GUIDELINES WATER SUPPLY PARAMETERS Water supply community or private well Potable suitable for drinking Water Pressure 30 100 psi 207 690kPa 40 100 F 4 4 38 C Water Temperature pH Range Maximum TDS Level 500 ppm Dissolved Iron lt 0 1 ppm Dissolved Manganese lt 0 05 ppm Turbidity lt 1 NTU Water supplies that exceed limits
6. Sink faucet Part No 4319154 available from your Whirlpool dealer Includes faucet base with blue tubing attached assembly hardware faucet spout 2 way grey connector with push in ends and a T grey connector with push in ends Open This Flap For Installation Overview Installation Overview Before You Start IMPORTANT Read and save these instructions It is recommended that this system be installed by a licensed plumber It is the responsibility of the installer to comply with the installation specifications provided and with state and local If you need assistance Refer to the Use amp Care information at the end of this booklet If you need more help the Whirlpool Consumer Assistance Center will answer any questions you may have about operating or maintaining your water filtration system The Whirlpool Consumer Assistance Center is open 24 hours a day 7 days plumping cades a week Just dial 1 800 253 1301 the call is free A A i a If you decided to install the system yourself see General When you call you will need the water filtration oo REE NS esse JJ Information on page 9 before continuing system model number and serial number Both aa Water Filtration Systems I II and III can be installed in the basement it numbers can be found labeled on the filtration Es LaL there is not adequate room for under sink installation Order additional assembly
7. and allow water to run for 5 minutes to check system for leaks If water is leaking shut off water and recheck connections Replace cover Preparation for long periods of non use Follow these instructions if system will not be used for more than 30 days 1 Turn off water supply at either saddle valve or main shut off Press refrigerator water dispenser to empty water into a container If using the optional sink faucet turn on faucet to drain any water in system Discard this water Wait five minutes for filtration assembly to depressurize 2 Remove all cartridges and place upside down in sink or bucket to drain water from cartridges Place cartridges in plastic bag and seal tightly Place bag with cartridges in refrigerator Do Not allow cartridges to freeze Using water filtration system after long periods of non use 1 Follow instructions for replacing cartridges 2 Follow Start Up instructions 3e and 3f Call 1 800 253 1301 to order Replacement Parts amp Accessories Kit includes Sediment Carbon SC Cartridge System Replacement Cartridges Kit I Rit includes Lead Reduction L and Carbon Filter CF Cartridges Cartridges can also be ordered individually System III Replacement Cartridge Kit Kit includes Lead Reduction L and two Carbon Filter CF Cartridges Cartridges can also be ordered individually Sediment Carbon SC Cartridge 14373529 Lead Reduction L
8. discard short piece of blue tub ing from grey connector with push in end on the back of filtration assembly Insert one end of long piece of blue tubing into this grey connector with push in end Run the blue tubing from the filtration assembly to the refrigerator remove short 2 insert long blue tubing j blue tubing 2 Route blue tubing to rear of refrigerator Cut C blue tubing to shortest possible length Insert free end of blue tubing into the 2 way grey connector with push in ends as far as it will go Turn off refriger ator water supply and ice maker Press refrigerator water dispenser to empty water into a container Disconnect main water supply from refrigerator s water line Seal main water line hole because it will no longer be connected to refrigerator Make sure the refrigerator water line has a square cut Then insert refrigerator water line into other end of the 2 way grey connector with push in ends Proceed to step 3 DL on f refrigerator ubing water line sales 2 Connect system to optional sink faucet a only A 6 diameter opening in the sink is required to install the optional sink faucet Important If you do not have an existing sink opening contact a qualified installer or licensed plumber to cut an opening in your sink CAUTION Property Damage e Contact a qualified installer or licensed plumber for cutting a faucet opening in your ink Failure to do so may result in damage to th
9. of the connector Cut at least 1 4 from the end of the tubing to create a new smooth end or replace if necessary t screw tubing If a cartridge head leaks it may have a misaligned pinched or damaged O ring Shut off the slot saddle valve or other existing water valve Press refrigerator water supply or optional sink faucet to drain water from system Wait five minutes for filtration assembly to depressurize Turn filter cartridge 14 turn to the left and remove Replace the O ring if it is misaligned pinched or damaged X A receptacle tabs cartridge o ring A seals tabs Maintaining your water filtration system The maximum length of time a filter cartridge should be used is one year Cartridges should be replaced every 500 gallons but exactly how often cartridges are replaced will depend on local water conditions Private wells may require more frequent cartridge replacement while softened water systems may require cartridge replacement only once a year Cartridge Replace at least Or replace if or when Sediment SC Once year or Water supply is cloudy every 1 000 gals has high dirt and rust content change every six months Water amount or flow from faucet is noticeably reduced Water supply smells of chlorine Lead Reduction L Once yoar or Water supply smells every 500 gals of chlorine or water has high dirt and rust content change every six months Carbon CF
10. piercing lance a maximum of 346 beyond the rubber gasket Align piercing lance over hole you drilled in pipe Then assemble saddle valve on pipe with large U side against pipe qi Tighten bottom screw firmly l keeping bracket parallel to pipe Turn saddle valve handle clockwise until nut piercing lance enters hole in pipe and then stops The saddle valve is now in the closed position 1i Have a towel ready in case of a leaks Turn on cold water supply to check for leaks in case of leaks use an adjustable wrench to tighten nut below valve s handle Turn cold water back off 1 Remove cover from filtration a assembly by lifting straight up Move filtration assembly near area where it will be mounted either under sink or in the basement For best results locate filtra A tion assembly so i tubing can be cut to shortest length possi ble To connect one end of orange tubing to the saddle valve place the brass compression nut on the IT orange tubing threaded side out place the EE plastic sleeve onto the tubing discard brass sleeve push the insert into the tubing and thread this assembly onto the opening of the saddle valve Tighten brass compression nut with Va wrench Use a plastic tubing cutter or sharp razor knife to cut tubing to shortest possible length Make sure cut end is clean and blunt and tubing is round Push free end of orange tubing as far as it will go into the grey push in fitting on t
11. ATION Part No 4373576 Whirlpool Corporation 1993 Whirlpool Corporation Benton Harbor MI 49022 Printed on Recycled Paper in U S A
12. Cartridge i 373530 Carbon Filter CF Cartridge 73531 19153 19154 73563 73565 373572 Additional Parts Va Tubing 4319151 Needed for Multiple i x Connections T Connector with Push in Ends 4319152 Additional tubing for basement installation 4319151 If You Need Assistance The Whirlpool Consumer Assistance Center will answer any questions about operating or maintaining your water filtration system not covered in the Installation Instructions and Use and Care Guide The Whirlpool Consumer Assistance Center is open 24 hours a day 7 days a week Just dial 1 800 253 1301 the call is free When you call you will need the water filtration system model number and serial number Both num bers can be found labeled on the filtration assembly How To Arrange For Service In the event that your Whirlpool appliance should ever need service call the dealer from whom you purchased the appliance or a Whirlpool authorized service company A Whirlpool authorized service company is listed in the Yellow Pages of your telephone directory under Appliances Major Service or Repair You can also obtain the service company s name and telephone number by dialing free within the continental United States the Whirlpool Consumer Assistance Center telephone number 1 800 253 1301 A special operator will tell you the name and number of your nearest Vvhiripool authorized service company Maintain the quality built into your Wh
13. E UNIT PLEASE READ THE PERFORMANCE DATA SHEET THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSF STANDARD 42 FOR CHLORINE TASTE AND ODOR REDUCTION CLASS I AND PARTICULATE REDUCTION CLASS II AND UNDER NSF STANDARD 53 FOR LEAD CYST AND TURBIDITY REDUCTION WHIRLPOOL BENTON HARBOR MI USA IT IS ESSENTIAL THAT OPERATIONAL MAINTENANCE AND FILTER REPLACEMENT REQUIREMENTS NSFe BE CARRIED OUT FOR THE PRODUCT TO PERFORM AS ADVERTISED WATER FILTRATION SYSTEM III MODEL NO WSC300YW ol REPLACEMENT CARTRIDGE WHIRLPOOL L FSP 4373530 WHIRLPOOL CF FSP 4373531 CORPORATON RATED SERVICE FLOW 0 6 gpm 2 28 Ipm MAX OPERATING PRESSURE 100 psig 862 kPa MAX OPERATING TEMPERATURE 100 F 38 C NOTICE ACTIVATED CARBON FILTERS ARE NOT INTENDED FOR USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR WITH WATER OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE UNIT PLEASE READ THE PERFORMANCE DATA SHEET THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSF STANDARD 42 FOR CHLORINE TASTE AND ODOR REDUCTION CLASS I AND PARTICULATE REDUCTION CLASS II AND UNDER NSF STANDARD 53 FOR LEAD CYST AND TURBIDITY REDUCTION SEE PERFORMANCE DATA SHEET FOR PERMISSIBLE VOC CLAIMS WHIRLPOOL BENTON HARBOR MI USA IT IS ESSENTIAL THAT OPERATIONAL MAINTENANCE AND FILTER REPLACEMENT REQUIREMENTS NSFe BE CARRIED OUT FOR THE PRODUCT TO PERFORM AS ADVERTISED 11 Performance Data Sheet This product has been tested and li
14. achloroethane 80 95 eae Les ns i 1 1 Dichloroethylene 50 73 1 2 Dichlorobenzene 80 95 The performance and functioning of your water filtration system is directly related to the quality of 1 1 1 Trichloroethane 802 54 1 2 Dichloroethane 80 95 the water being treated and the particular application in which it is used Please consult Water 1 2 Dichloroethane 100 53 Requirements and Use amp Care 2 4 Ethylbenzene 807 4 gt Whirtpoo shall not be liable for incidental or consequential damages Some states do not allow Tetrachloroethylene 80 4 the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may Toluene 80 4 not apply to you 1 2 Dichloropropane 80 53 influent levels are the 95th percentile occurrence levels are per Federal Register Vol 50 No 219 November 13 1985 p 46917 2Since the 95th percentile occurrence levels were too low and thus were not pertinent for testing these chemicals against their MCL s a reasonable level was selected for surrogate testing as shown 3EPA Primary Maximum Contaminant Levels 4Maximum effluent concentrations set at the practical quantitation level PAL which is less than the MCL Sin the absence of officially stated occurrence levels and MCL s the surrogate influents were selected to provide a reasonable test This warranty gives you specific legal rights and you may also have other rights which vary from state to state CORPOR
15. e sink 2 Remove and discard short clear piece of e a tubing from top of faucet base and push faucet spout into this opening Place the escutcheon plate and black rubber washer on the faucet s thread ed nipple Note Rubber washer may be removed and replaced with a bead of plumber s putty for a neater appearance Feed blue tubing through sink hole Position faucet spout over sink Working below the sink secure faucet with black plastic washer locking washer and nut Side view of faucet i faucet spout q faucet base black rubber washer sink escutcheon plate locking vesher p VE black plastic washer nut q threaded nipple lt Dbilue tubing 2 Recheck faucet position If position needs minor adjusting wrap the flat chrome sides of faucet and the crescent portion of the crescent wrench with masking tape to protect the chrome from scratches Use the wrench on ES flat sides of faucet to reposition g faucet Remove masking tape Remove and discard short piece of blue lt 9 a tubing from grey connector with push in on the back of filtration assembly Cut blue tubing from faucet to shortest possible length Insert free end of faucet s blue tubing into this grey connector with push in end Proceed to step 3 remove short blue tubing insert faucet s blue tubing 2 h Connect system to refrigerator and a optional sink faucet Follow steps 2d through 2f for faucet installation It
16. exible ribbed tubing contact your local plumbing supply distributor to obtain special connecting hardware Important If local codes do not permit the use of saddle valves special feed valves can be obtained from your local plumbing supply distribu tor Use only 4 polyethylene tubing for water line connection CAUTION Property Product Damage DO NOT install tubing in an area where temperatures drop below 32 F DO NOT overtighten saddle valve to copper pipe This will crush pipe Keep a bucket or towel under area where saddle valve connection is made Failure to follow these instructions may result in water damage to property or product damage Turn off cold water supply Turn on cold 1b a water faucet and allow all water to drain from line Turn off faucet Determine if your cold water sup ply line is soft copper pipe or rigid metal or plastic pipe If your cold water supply line is soft copper pipe pro ceed to step 1c If your cold water supply line is rigid metal or plastic pipe skip ahead to step 1h f i i i 1 Connect saddle valve to cold water supply C soft copper pipe Check that saddle valve piercing lance does not protrude beyond rubber gas ket If itis protruding carefully push it in flush with the rubber gasket using a hard object like the end of a screwdriver handle piercing lance should not nut protrude reversible bracket BEN ECTS _ copper pipe
17. f you are in doubt as to whether your electric drill is properly grounded Only drill at top or side of horizontal water supply pipe DO NOT drill at bottom of horizontal pipe where water may remain Failure to follow these instructions could result in personal injury or death 2 Turn on faucet to drain water from line Step 1b 3 Connect saddle valve to cold water supply Turn saddle 4 Connect one end of orange tubing to saddle valve valve handle clockwise until piercing lance enters Connect other end to filtration assembly Step 1k pipe and stops Steps 1c 1g or 1h 1 Hook Up Water CAUTION Product Damage DO NOT connect to a hot water supply line Failure to follow this instruction could result in product damage 1 Take note of water requirements listed under a the Use amp Care section of this booklet The filtration system s feed line orange tubing connects to your cold water supply line using the saddle valve Do not use saddle valve if it is prohibited by your state or local plumbing codes The saddle valve is for use with 38 to 58 outer diameter O D soft copper pipe plain or chrome plated or rigid metal or plastic pipe Important DO NOT use the saddle valve on flexible ribbed tubing The wall thickness of flexible ribbed tubing is thin and will not support the saddle valve supplied If your cold water supply is connected to the cold water faucet with fl
18. for iron or manganese require pretreatment It is essential that operational maintenance and filter replacement requirements be carried out for the product to perform as advertised CAUTION Do Not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit 1 0 NTU Contaminant Reduction U S EPA Average Maximum Minimum NSF Test Performance MCL Influent Effluent Reduction Requirement 5 maximum effluent 5 o maximum effluent Lead pH 8 5 0 015 mg L 0 17 mg LS 0 002 mg L 0 015 mg L Free Available Chlorine 2Test requirement is at least 10 000 Particles mL of AC Fine Test Dust 3Test requirement is 4 6 micrometer size particles per mL of influent These contaminants are not necessarily in your water supply Performance may vary based on local water conditions 5Tesi requirement 0 15 mg L 15 WARRANTY Length of Warranty One Year Full Warranty From date of purchase Whirlpool will pay for Replacement parts and repair labor to correct defects in materials or workmanship for the entire product except for the filter cartridge s Service must be provided by an authorized Whirlpool servicing outlet Five Year Limited Warranty Second through fifth year from date of purchase Replacement parts to correct defects in materials or workmanship for the entire product except for the filter cartridge s Whirlpo
19. he front right side of the filtration assembly orange sleeve tubing brass compression nut orange tubi g system Connection 1 Decide if the system will be connected to your refrigerator to an optional faucet or to both Step 2a 2 Connect refrigerator s water supply to filtration assembly with blue tubing Steps 2b 2c 3 Or install faucet in sink and connect blue tubing 4 Or use T grey connector to connect both to filtration assembly Steps 2d 2g refrigerator and faucet Steps 2h 2i System Connection 2 You have three installation options a 1 Connect water supply from filtration system to refrigerator s ice and water only 2 Connect water supply from filtration system to optional sink faucet only 3 Connect water supply from filtration system to both refrigerator and optional sink faucet All parts are included with this kit to connect refrigera tor If you choose to connect filtration system to a sink faucet order sink faucet Part No 4319154 available from your Whirlpool dealer This kit includes faucet assembly with blue tubing attached assembly hard ware faucet spout 2 way grey connectof with push in ends and a T grey connector with push in ends This T grey connector with push in ends will allow you to connect filtration assembly to both the faucet and the refrigerator 2 b Connect system to refrigerator only a Remove and
20. inuous flow To stop water flow from the faucet return the faucet to the center or horizontal position General Information Due to shipping some carbon grains may appear in the first few gallons of water through your filtration system Simply flush the system until water becomes clear This system can be connected to two dispensing points including the optional sink faucet We do not recommend installing this water filtration system to your existing tap faucet as the flow rate will be reduced to 6 gallons per minute e Remember to cut all tubing to the shortest possible length to maximize your flow rate e Maintenance of this water filtration system is very important Replace the Sediment S Lead Reduction L and Carbon Filter CF cartridges annually Failure to maintain this water filtration system over an extended period of time could present health risks Use amp Care Information Water Requirements The filtration system must be connected to a cold water supply line providing 30 100 psi water pressure The water temperature must be between 40 100 F Community or private well water must be potable suitable for drinking WARNING Personal Injury Hazard DO NOT use water filtration system if water is microbiologically unsafe or water quality is unknown Failure to follow these instructions could result in personal injury General tips To correct a leaky saddle c Hf ff valve turn off cold wate
21. irlpool appliance call a Whirlpool authorized service company 0 Be ad od ad bad Pa pact Fact D amp G ja SI Q N N N N g Q Q w 8 S g K A s c o o Whirl lt gt Whitt WATER FILTRATION SYSTEM MODEL NO WSC100YW ef Whirl ol REPLACEMENT CARTRIDGE WHIRLPOOL SC FSP 4373529 COMCRATON RATED SERVICE FLOW 0 6 gpm 2 28 Ipm MAX OPERATING PRESSURE 100 psig 862 kPa MAX OPERATING TEMPERATURE 100 F 38 C NOTICE ACTIVATED CARBON FILTERS ARE NOT INTENDED FOR USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR WITH WATER OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE UNIT PLEASE READ THE PERFORMANCE DATA SHEET THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSF STANDARD 42 FOR CHLORINE TASTE AND ODOR REDUCTION CLASS AND PARTICULATE REDUCTION CLASS I WHIRLPOOL BENTON HARBOR MI USA IT IS ESSENTIAL THAT OPERATIONAL MAINTENANCE AND FILTER REPLACEMENT REQUIREMENTS NSFe BE CARRIED OUT FOR THE PRODUCT TO PERFORM AS ADVERTISED WATER FILTRATION SYSTEM II MODEL NO WSC200YW ol REPLACEMENT CARTRIDGE WHIRLPOOL L FSP 4373530 WHIRLPOOL CF FSP 4373531 CORORANON RATED SERVICE FLOW 0 6 gpm 2 28 Ipm MAX OPERATING PRESSURE 100 psig 862 kPa MAX OPERATING TEMPERATURE 100 F 38 C NOTICE ACTIVATED CARBON FILTERS ARE NOT INTENDED FOR USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR WITH WATER OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER TH
22. is strongly recom mended that only a licensed plumber or professional installer cut an opening in the sink Cut blue tubing from faucet to Fa shortest possible length Push the faucet s blue tubing as far as it will go A onto one end of the T grey connec longl blue tor Push the other end of the T grey Es ret Ll connector as far as it vvill go onto the short piece of blue tubing on the back of the filtration assembly Push the long piece of blue tubing onto the center push in end of the T grey connector 2 g Route blue tubing to refrigerator Cut blue tub i ing to shortest possible length Insert free end of blue tubing into the 2 way grey connector with push in ends as far as it will go Turn off refrigerator water supply and ice maker Press refrigerator water dis penser to empty water into a container Disconnect main water supply from refrigerator s water line Seal main water line hole because it will no longer be con nected to refrigerator Make sure the refrigerator water line has a square cut Then insert refrigerator water line into other end of the 2 way grey connector with push in ends Proceed to step 3 VP long blue En 2wey grey tubing faucet tubing StartUp Instructions At A Glance For detailed instructions see following page 1 Slide filtration assembly onto mounting screws Steps 3a 3c 3 If filtration assembly was connected to refrigerator make and discard 2 batches
23. of ice and drain 4 If filtration assembly was connected to sink faucet lift 2 3 gallons of water from water dispenser Step 3e faucet handle to discard 2 3 gallons of water Step 3f WARNING Electrical Shock Hazard Special care must be taken when drilling into walls Electrical wires may be concealed behind the wall covering Use only an electric drill with a 3 wire power supply cord connected to a grounded receptacle Check with qualified electrician if you are in doubt as to whether your electric drill is properly grounded Failure to follow these instructions could result in personal injury or death 3 Mount filtration assembly a Solid Construction Cabinet Position the filtration assembly on either the right or left cabinet wall and allow a minimum of 2 clearance above the cabinet floor Mark the location of the filtration system s bracket holes then set the filtration assem bly aside and skip ahead to step 3b Non solid Construction Cabinet Replace filtration assembly s cover Position the filtration assembly on the cabinet floor along either the right or left cabinet wall Skip ahead to step 3c Basement Installation Position the filtration assembly on wood floor supports or on basement wail Mark the location of the filtration assembly s bracket holes then set the filtration assembly aside Additional tubing may be required and is available from your local plumbing distributor o
24. ol will not pay for A Service calls to 1 Correct the installation of the product System must be installed and operated in accor dance with Whirlpool procedures and guidelines 2 Instruct you how to use the product 3 Correct house plumbing B Repairs when product is used in other than normal single family household use VOLATILE ORGANIC CHEMICAL REDUCTION This system has met the testing requirements of Standard 53 Section 5 1 1 for the reduction of chloroform which is the surrogate for the following chemicals Maximum influent Minimum Occurrence _ Effluent ee Concentration Percent Repairs when product is damaged from neglect misuse abuse freezing or hot water fouling Chemical Levels ppb Level ppb Other VOC s ppb Reduction with sediment or scale bacterial attack alterations improper installation or installation not in Benzene 3 30 58 cis 1 3 Dichloropropene 80 95 accordance with local plumbing codes Cabon Lecce a0 Chidrobonzene P H ie Any labor costs during the limited warranty _ p Dichlorobenzene i i exacniorobutagiene Re Replacement parts or repair labor costs for units operated outside the U S Trichloroethylene 300 5 ortho Xylene 80 95 Pickup and delivery This product is designed to be repaired in the home Trihalomethanes 300 15 trans 1 2 Dichloroethene 80 95 Repairs to parts or systems caused by unauthorized modifications made to the product surrogate chemical 1 1 2 2 Tetr
25. r A supply and make sure bot Ar tom screw is tightened evenly and firmly DO NOT overtighten you could crush the pipe Then make sure the nut below the saddle valve s handle is tight If not tighten it with a 78 wrench If the threaded portion of the brass compression nut that is attached to the saddle valve leaks turn off saddle valve and remove the nut wrap Teflon tape around the threaded portion 2 4 times Reconnect the nut If a leak should occur at a push in connector the cause is usually defective tubing To correct the problem turn off water supply to the sa system either at the saddle valve or pia other existing water valve Push in the grey push in connector and hold then pull the tubing out of the connector Cut at least 1 4 from the end of the tubing clean square cut using a plastic tubing cutter or a sharp razor knife Make sure the cut end is clean and blunt and that tubing is round Reinsert tubing as far as it will go Turn on water supply at valve lf the refrigerator tubing leaks at the push in connec tor the refrigerator s water line metal tubing may be grooved or deformed To correct the problem turn off water supply to the system either at the saddle valve or other existing water valve Press refrigerator water supply or optional sink faucet to drain water from system Wait five minutes for filtration assembly to depressurize Push in the grey push in connector and hold then pull the tubing out
26. r from your Whirlpool dealer Continue with step 3b 3b Drill pilot holes for the mounting bracket at a the locations you ve marked Insert mounting bracket screws in holes and tighten leaving a slight gap between screw head and wall For basement installation and solid construction cabinet installation place filtration assembly mount ing bracket on mounting screws and tighten screws until filtration assembly is secure and replace cover 3 Make sure all tubing connected to grey C push in connectors is tight pushed in as far as it will go and that tubing does not bind or kink anywhere Also make sure tubing does not interfere with cabinet storage areas Tubing may be cut toa shorter length if necessary Tubing may be secured to cabinet walls with insulated staples as long as staples do not crush or puncture tubing 3 Place a towel or bucket under saddle valve s then turn on cold water supply and saddle valve and check for leaks 3 If filtration assembly was connected to refrig e a erator let ice maker produce two batches of ice and discard both batches This will flush the line of any accumulated particles If the refrigerator has a water dispenser flush the line by dispensing 2 3 gallons of water 3f If optional sink faucet was installed lift faucet a handle and dispense and discard the first 2 3 gallons of water To get filtered water hold the faucet handle down for momentary flow or hold the faucet up for cont
27. sted by NSF International under NSFe Standard 42 for Taste Odor and Chlorine reduction Class I and Particulate reduction Class Il Whirlpool Water Filtration System Model No WSC100YW SPECIFICATIONS Taste Odor Chlorine reduction Class CAPACITY 1 000 Gallons SERVICE FLOW RATE 0 6 GPM 2 2 L min 60 psi Performance influent Effluent Reduction Requirement ii o minimum 75 i 2 LA minimum 85 Performance may very based on local water conditions Free Available Chlorine eTest requirement is at least 10 000 particles mL of AC Fine Test Dust 12 This product has been tested and listed by NSF International under Standard 42 NSFe for Taste Odor and Chlorine reduction Class and Particulate reduction Class II and under Standard 53 for Cyst Turbidity and Lead reduction Whirlpool Water Filtration System II Model No WSC200YW SPECIFICATIONS Lead and Taste Odor Chlorine reduction Class I CAPACITY 500 Gallons SERVICE FLOW RATE 0 6 GPM 2 2 L min 60 psi Performance Influent Effluent Reduction Requirement Chlorine Contaminant Reduction U S EPA Average Maximum Minimum NSF Test Performance MCL Influent Effluent Reduction Requirement 5 o maximum effluent Lead pH 6 5 0 015 mg L 0 16 mg S 0 005 mg L 0 015 mg L 5 maximum effluent Lead pH 8 5 10 015 mg L 0 17 mg mL5 0 002 mg L 0 015 mg L Free Available Chlorine 2Test requirement is at least 10 000 particles mL of