Home

Tyco Electronics 0-1591046

image

Contents

1. can be connected to unshielded twisted pair UTP or shielded twisted pair STP cabling systems compliant with the IEEE 802 3u 100Base TX standard for Category 5 The cable between the switch and the link partner device router hub workstation etc must be less than 100 metres long 2 The fiber link on the optional multi mode module must use either 50 or 62 5 125 micron multi mode fiber cable You can link two devices over a distance of up to 2 kilometres 3 The fiber link on the optional single mode module must use 8 125 or 9 125 micron single mode fiber cable You can link two devices over a distance of up to 15 kilometres in full duplex mode or 412 metres 1 352 ft in half duplex 4 The console port is an RS232 port and should not be used for cable distances greater than 20 metres Desktop Installation 1 Locate the switch in a clean flat and safe position that has easy access to AC power Ensure that there is sufficient clearance around the switch to enable air circulation 2 Fit the self adhesive rubber feet to the underside of the switch Installing The Switch Into A 19 Rack 1 Identify the required locations and ensure that there is at least 10cm clearance at the front and rear of the switch to allow cables to be accommodated 2 Fit the supplied rackmount bracket on both side plates of the switch using a screwdriver 3 Locate the switch into the rack and align the holes in the brackets with holes in the rack ve
2. the 1310nm optical wavelength for both the multimode and singlemode media converters The fiber size used for multimode links is 50 125 or 62 125 micron The fiber size used for singlemode links is 8 125 or 9 125 micron The maximum distance between any two fiber optic devices is determined by a number of factors including optical link loss the type and number of patch cords and joints in the link the launch power of the transmitter and the sensitivity of the receiver These variables make calculating the maximum working distance between two converters quite difficult and so it is best to design networks using optical loss budgets rather than using just working distance Average Average Plug in Fiber Ethernet Average Power Sensitivit Module Type Launch Loss Budget dB y Power dB dBm Multimode Converter SC 18qB 12dBm 30dB Multimode Converter ST 18dB 12dBm 30dB Multimode Converter MT RJ 16aB 14dBm 30dB Singlemode Converter SC 18dB 12dBm 30dB Table 2 Optical Specifications Tyco Electronics Page 8 16 Port Ethernet Switch With Optional Fiber Port Product Specification Standards Compliance IEEE 802 3 10Base T Ethernet IEEE 802 3u 100 BASE TX Fast Ethernet IEEE 802 3u 100 Base FX Fast Ethernet ANSI IEEE standard 802 3 N way Auto Negotiation Max Forwarding Rate 14 880 pps Ethernet port 10Mbit s 148 800 pps Fast Ethernet por
3. of incorrect negotiation include data errors and fragmented packets 2 Auto negotiation can take up to 30 seconds to complete depending on the partner device 3 Ensure that the switch is not overheating due to obstructed airflow around the side vents Optional Fiber Uplink Module 1 Select the proper fiber cable for your network The multi mode module must use multi mode fiber cable and the single mode module must use single mode fiber cable See page 4 for the supported cable types and installation settings 2 Ensure that the optical loss budget of the fiber uplink is within the limits specified on page 8 Note that optical patch cables and other joints and splices can introduce additional optical losses that reduce the working distance of the fiber link If you still have problems and need further advice please see Technical Support section on page 2 to obtain more information Tyco Electronics Page 7 16 Port Ethernet Switch With Optional Fiber Port Accessory Product Part Numbers The following plug in fiber modules are available as accessory products for this switch Product Part Number Module with SC multimode connectors 0 1591050 0 Module with ST multimode connectors 0 1591052 0 Module with MT RJ multimode connector 0 1591054 0 Module with SC singlemode connectors 0 1591056 0 Consult dealer for precise order codes Optional Fiber Uplink Port Specifications The optional modules operate at
4. port Support for port based VLANs and Port Trunking Uses store and forward switching to separate collision domains and abnormal packet filtering Integral 8K MAC address table automatic learning Backplane bandwidth up to 3 2Gbit s Supports back pressure amp flow control Numerous diagnostic LED indicators Internal AC DC power unit Stand alone or mountable in 19 racking FCC Class A CE mark certification Technical Support and Service If you require technical advice for these products please see the FAQ pages on the web address hittp www lan electronics com If you still have problems please contact us using the support form located on the above web site If you have a faulty unit then please contact us through the web site to arrange for a replacement unit The faulty unit must be returned to us as part of the replacement agreement Tyco Electronics Page 2 16 Port Ethernet Switch With Optional Fiber Port Front Panel The front panel of the switch has 16 x RJ 45 Shielded Unshielded Ethernet Ports an optional fiber Ethernet 100Base FX uplink port a console management port and an array of LED indicators LED Indicators 10 100Base TX RJ 45 ports 100FX Module 1x 2X 3x ax 5x 6x 7x 8x B vine ox 10x 11 Console port Uplink port 12x Bx 14 15 O Figure 1 S
5. r Plug In Module LED Color Function 100Base FX fiber partner unit No fiber connection is detected UTP PORT FD COL FIBER PORT Orange The port is in full duplex mode FDX COL Collisions in half duplex mode No device attached or in half duplex Table 1 LED Status and description See optional fiber module manual or the web site for details Tyco Electronics Page 6 16 Port Ethernet Switch With Optional Fiber Port Trouble Shooting Power 1 Verify that the AC power is present and that the external fusing is correct and compliant with national requirements The green Power LED should be lit to indicate that the switch is powered correctly Data Problems 1 Ensure that the Ethernet partner device switch router NIC etc connected to the RJ 45 UTP port of the switch is set for auto negotiation If this Ethernet partner device does not support auto negotiation then you need to program that device to operate at 100Mbit s half duplex or 10Mbit s half duplex If this is not possible then the Tyco switch can be programmed from the front panel console port to apply the required speed and duplex modes to match the legacy partner equipment See the web site for the console programming guide If the switch and the partner device cannot auto negotiate then the units automatically revert to the lower level of half duplex operation This issue is common to all auto negotiating Ethernet devices and symptoms
6. rtical strips Secure the switch using the supplied bolts Installing The Optional Fiber Uplink Module See instructions on web site and module manual for further details 1 Remove the two screws securing the front panel blanking plate located in the right hand side of the panel 2 Ensure that there is no power on the switch and then carefully fit the plug in module and secure it using the thumbscrews Tyco Electronics Page 4 16 Port Ethernet Switch With Optional Fiber Port Completing The Installation When the switch has been installed as specified above then the unit can be configured as detailed below 1 Apply AC power to the switch The green Power LED on the front panel should light Connect the Cat 5 5e twisted pair cables from the network partner devices to the RJ 45 ports on the front panel of the switch In certain cases a cross over RJ 45 cable may be needed When a connection is obtained the green LK ACT LED associated with the port will light If the fiber uplink is not used then connect the RJ 45 uplink port to the required device router server etc When a connection is obtained the green LK ACT LED associated with port 16 will light Ensure that there is no connection to the standard RJ 45 port 16 If the fiber uplink is used then connect the fiber link to the partner device media converter fiber NIC card or fiber switch etc Ensure that the fiber uplink is set in the correct duple
7. t 100Mbit s LED Indicators Power Trunking UTP Ports Speed Link Activity Duplex Collision Ethernet LAN Copper Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 586 100 ohm 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 586 100 ohm Optional Fiber Link Max Distance ST SC MT RJ Multi mode Half duplex 412m Full duplex 2Km SC Single mode Half duplex 412m Full duplex 15Km Dimensions 440mm x 160mm x 44mm W x D x H Weight 2Kg Operating 0 C to 45 C 32 F to 113 F Temperature Operating 10 to 90 Non condensing Humidity Power Supply Internal 100v to 240v AC 50 60HZz auto ranging externally fused Power 16 Watts Max Consumption EMI FCC Class A CE Mark Table 3 Product Specifications Tyco Electronics Page 9
8. tyco Electronics 16 Port 10 100Mbit s Ethernet Switch with Optional Fiber Uplink Port Product User Guide Introduction This Tyco Electronics auto negotiating Fast Ethernet workgroup switch with optional fiber uplink enables clusters of up to 16 users to have high speed low latency LAN connections to the corporate network Local management functions such as control of port speed duplex mode port trunking and VLAN membership are supported The optional fiber uplink module enables the switch to be connected using a fiber link to servers routers and other devices over distances of up to 2km for multimode or 15km for singlemode Package Contents Unpack the contents and verify them against the items below 1 16 Port Ethernet Switch with fiber uplink option port AC Power cord Four rubber feet Rack mounting kit 2 x brackets and 4 x screws RS 232 cable a A O N If any item is damaged or missing please contact your dealer Product Part No 0 1591046 x EMEA PL0334 Issue 1 2 16 Port Ethernet Switch With Optional Fiber Port Features 16 x Auto sensing 10 100Base T RJ 45 Ethernet ports 1 x Option slot for 100Mbit s fiber uplink module that operates over distances of up to 2Km multi mode or 15 Km single mode fiber 1 x Additional 10 100Mbit s RJ 45 port for uplinking Meets IEEE 802 3 3u and 3x Ethernet standards Local management using an RS232 console port Management enables detailed control of each
9. witch with optional fiber module SC Connector fitted Ports m RJ 45 Ports These Ethernet RJ 45 ports support both shielded and unshielded cabling systems The port auto negotiates the 10 100Mbit s network speed or can be forced by the console management interface into either 10Mbit s or 100Mbit s at either full duplex or half duplex E Uplink RJ 45 Port This port is intended for connection to an uplink device without needing a cross over cable This is a standard 10 100Mbit s Ethernet interface and shares the same port assignment as RJ 45 port 16 Therefore do not use Port 16 when using this RJ 45 uplink m 100FX Fiber Port This optional field installable plug in module provides the fiber link to the distant media converter NIC card or Ethernet switch The port operates in either full duplex or half duplex modes depending on the setting of DIP switch on the front panel of the plug in module Modules with SC ST and MT RJ fiber optic connectors are available See page 8 for order codes Console Port APC or other RS232 terminal is connected to this port to enable detailed management of the switch See the documentation on the web site for full information Rear Panel The rear panel contains the 110 240v AC 50 60Hz power socket Note that the fusing is external to the switch Tyco Electronics Page 3 16 Port Ethernet Switch With Optional Fiber Port Installation Copper and Fiber Cabling Guidelines 1 The RJ 45 ports
10. x mode default Full Duplex using the front panel switch on the module Verify that the green Link LED on the fiber module is lit which indicates that the optical link is valid If advanced modes such as port trunking or port based VLANs are needed then use the console port to configure the switch See the console port instructions on the web site for further details If there are legacy devices that do not support auto negotiation connected to the RJ 45 ports then it may be necessary to program the switch using the console port See the console port instructions on the web site for further details Note that auto negotiation can take up to 30 seconds to complete depending on the partner device Tyco Electronics Page 5 16 Port Ethernet Switch With Optional Fiber Port LED Indicators The diagnostic LED indicators located on the front panel of the switch provide real time information about switch status The following table describes the LED status and meaning Function Power Green Power on i The switch is trunking to another The UTP port is operating at 100Mbit s The UTP port is operating at 10Mbit s or no partner device is attached Ethernet link pulses are present LK ACT Off Port transmitting or receiving packets Off Off ooo No device is attached or faulty cable The port is in full duplex mode Blinks Collisions in half duplex mode The port is in half duplex mode Optional Fibe

Download Pdf Manuals

image