Tripp Lite 240/415V Power Supply User Manual

image

Contents

1. OUTPUT LOAD R XXX XXX XA S XXX XXX XA T XXX XXX XA i Press SELECT Button Output Load amp Current MAINS INVERTER R XXXV R XXX XV S XXXV S XXX XV T XXXV T XXX XV i Press SELECT Button Mains amp Inverter Voltage BYPASS XX X Hz MAINS XX X Hz OUTPUT XX X Hz INVERTER XX X Hz J Press SELECT Button Bypass Mains Output amp Inverter Frequency CHARGE _ FLOATING CHARGER XXX XV BATTERY XXX XV BATTERY XXX X Press SELECT Button Charger Mode Charger Battery Voltage amp Battery Percentage SN XXX DC BUS XXV XXV Serial Number DC BUS Voltage Temperature amp Firmware Version TEMP XXX X C VERSION XXX Press SELECT Button ON UPS START OFF UPS BYPASS Button Functions SEL UPS MESSAGE ENT SET UPS Press SELECT Button Operation Special Conditions OPERATION ON BYPASS VOLTAGE OUT OF RANGE While in Bypass Mode the UPS monitors the input voltage which on Bypass equals the output voltage If the output voltage passes out of an acceptable range between 15 higher and 20 lower than nominal the UPS displays the condition on its LCD and stops supplying output power to its load If power levels return to an acceptable level the UPS resumes supplying power to the load and its LCD reports that output voltage was too high or too low at one time but h
2. cold start press the OFF button 11 AC Input Switch One triple pole circuit breaker controls input power to the UPS during normal operation 12 Bypass AC Input Switch One triple pole circuit breaker controls input power to the UPS during BYPASS operation 13 Remote Emergency Power OFF EPO Connector This modular jack allows remote emergency shutdown See Communications for details Rear Panels continea Refer to the Battery Module s Owner s Manual for all safety warnings and connection instructions 14 Fuse Holder externally accessible fuses protect against short circuit damage If a heavy overload or short circuit is encountered a fuse will blow A Battery Module with a blown fuse will not deliver any output voltage to the connected UPS System A qualified electri cian must replace the fuses 15 Internal Battery Trays the Battery Module contains five trays of batteries with four batteries per tray to supply extended runtime to a connected UPS System After disconnection the trays slide out for removal Fuses must be removed before any maintenance is performed 16 Cables for Battery Tray Interconnection internal connect the battery trays to supply DC battery power to a connected UPS System 17 Cables for UPS System Connection external connect the internal batteries through the fuse holder to a compatible Tripp Lite UPS System Do not replace these cables Using improper cables may damag
3. Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com 2009XXXXX 93 2260_ES
4. and 40 C For best results keep indoor temperatures between 62 F and 84 F between 17 C and 29 C e Leave adequate space around all sides of the UPS for proper ventilation Do not install the UPS near magnetic storage media as this may result in data corruption UPS Connection Warnings e The power supply for this unit must be three phase rated in accordance with the equipment nameplate It also must be suitably grounded according to all applicable local electrical wiring regulations Equipment Connection Warnings Do not use Tripp Lite UPS Systems in life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device e The UPS system contains its own energy source battery The output terminals may be live even when the UPS is not connected to an AC supply Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Because the batteries present a risk of electrical shock and burn from high short circuit current batteries should be changed only by trained service personnel observing proper precautions Consult your battery module manual before proceeding Remove watches rings and other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of the batteries Do not short or b
5. and power conditions Using this port an IBM AS 400 computer can automati cally save open files and shut down its operating system during a blackout See Communications for details 7 Smart RS 232 Interface Port This female DB9 port connects your UPS to a workstation or server It uses RS 232 communications to report UPS and power conditions It is used with Tripp Lite software and the included RS 232 Cable to monitor and manage network power and to automatically save open files and shut down equipment during a blackout See Communications for details 8 Dry Contact Interface Port This female DB9 port sends contact closure signals to indicate line fail and low battery status See Communications for details 9 Accessory Slot Remove the small cover panel and use optional accessories to remotely control and monitor your UPS Contact Tripp Lite Customer Support for more information and a list of available SNMP network management and connectivity products 10 Battery Start Switch This momentary rocker switch allows you to cold start your UPS and use it as a stand alone power source when utility supplied AC power is not present The switch enables the UPS s DC AC Inverter Before cold starting your UPS make sure your power module and external battery module s are properly installed Press and hold the Battery Start Switch and then press the ON button to turn your UPS ON To turn it OFF after
6. rights and you may have other rights which vary from jurisdiction to jurisdiction Tripp Lite 1111 W 35th Street Chicago IL 60609 USA WARNING The individual user should take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice Specifications The specifications listed below are for Tripp Lite model SU20K3 3X and SU30K3 3X which each include two modules a power module and a battery module The two modules are also sold separately with their own individual model numbers Model SU20K3 3X Model SU30K3 3X Includes Power Module e Battery Module Model SU20K3 3INTPM Model BP240V33 Input Input Voltage 220 380 230 400 240 415V AC 39 4 wire plus ground wye Includes Power Module e Battery Module Model SU30K3 3INTPM Model BP240V33 Input Input Voltage 220 380 230 400 240 415V AC 39 4 wire plus ground wye Input Frequency 50 60 Hz 3 Hz auto selectable Input Frequency 50 60 Hz 3 Hz auto selectable Voltage Correction Range 156 280 270 485V AC Voltage Correction Range 156 280 270 485V AC Input C
7. 110A Short Circuit Capability 2150A Crest Factor 3 1 Crest Factor 3 1 Battery Battery Battery Type Sealed Lead Acid 12V 33 AH Battery Type Sealed Lead Acid 12V 33 AH Battery Quantity 20 Battery Quantity 20 Protection 2x 125A 400V fuse Protection 2x 125A 400V fuse Typical Backup Time Half Load 30 min Typical Backup Time Half Load 18 min Typical Backup Time Full Load 12 min Typical Backup Time Full Load 6 min Operation Operation On Line Transfer Time 0 ms On Line Transfer Time 0 ms Line to Battery Battery to Line Line to Battery Battery to Line Audible Noise lt 65 dBA Audible Noise lt 65 dBA Full Load 1 meter Full Load 1 meter Indicators Includes an LCD Display and LEDs AC Line In Bypass Line In AC to DC DC to AC AC Output Battery Back Up Bypass Indicators Includes an LCD Display and LEDs AC Line In Bypass Line In AC to DC DC to AC AC Output Battery Back Up Bypass Communications Includes an RS 232 DB9 female connector an AS 400 DB9 female connector a dry contact DB9 female connector and an accessory slot Communications Includes an RS 232 DB9 female connector an AS 400 DB9 female connector a dry contact DB9 female connector and an accessory slot Connections Connections Input Terminal Block 100A Input Terminal Block 100A Output Terminal Bloc
8. N Choose appropriate cabling rated VW 1 FT 1 or better to connect your UPS Battery Module to your UPS Power Module UPS System Model Wiring Size 20kVA 4 AWG 22 mm 30kVA 2 AWG 38 mm Maximum Cable Length 10 m 32 8 ft Installation continued WIRING CONNECTION Connect your wiring from the positive negative and ground terminals on the UPS Battery Module to the positive negative and ground terminals on the UPS Power Module CAUTION Qualified personnel should follow all procedures prescribed by N E C and other local codes for hardwiring devices Ensure that cables are fitted with cable sleeves and are secured by connector clamps Tighten connections with a torque of not less than 35 inch pounds Observe the appropriate cable connection regulations e g National Electrical Code NEC in the U S at all times Using cables of improper size may damage your equipment and cause fire hazards For equipment requiring a neutral connection to an IT power distribution system the disconnect device shall be a four pole device and shall disconnect all line conductors and the neutral conductor If a disconnect device interrupts the neutral conductor it shall simultane ously interrupt all line conductors OUTPUT VOLTAGE SELECTION VIA SOFTWARE The UPS s output voltage is factory set at 220 380V AC If you require output voltage of 230 400V AC or 240 415V AC you must change the UPS s output voltage v
9. Owner s Manual SmartOnline 3 Phase 20kVA amp 30kVA Intelligent True On Line UPS Systems Input Output Voltage 220 380 230 400 240 415V AC 39 4 wire plus ground wye User selectable For all UPS system modules power module and battery module sold either separately or combined Select UPS system modules may include separate instruction or warning sheets which should be used in conjunction with this manual Fimportant Safety Warnings C gt E C C Operation Normal Conditions aD Operation Special Conditions Mcommunicstons MseviceMarany Mspeciicatons a auau o Espa ol 14 TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com Copyright 2005 Tripp Lite All rights reserved SmartOnline is a trademark of Tripp Lite Important Safety Warnings SAVE THESE INSTRUCTIONS This manual contains important instructions and warnings that should be followed during the installation and maintenance of all Tripp Lite SmartOnline 3 Phase 20k VA and 30kVA UPS Systems and their batteries UPS Location Warnings e Install your UPS indoors away from heat direct sunlight dust and excess moisture or other conductive contaminants e Install your UPS in a structurally sound area Your UPS is extremely heavy take care when moving and lifting the unit e Only operate your UPS at indoor temperatures between 32 F and 104 F between 0 C
10. TDOWN VERSION XXXXXXX VERSION XXXXXXX Overtemperature ON BYPASS Remote Shutdown BYPS OFF NO O P HIGH TEMP REMOTE SHUTDOWN SHUTDOWN SHUTDOWN VERSION XXXXXXX VERSION XXXXXXX DC BUS Overvoltage ON BYPASS Emergency Stop BYPS OFF NO O P DC BUS O V P EMERGENCY STOP SHUTDOWN SHUTDOWN VERSION XXXXXXX VERSION XXXXXXX DC BUS Failure ON BYPASS DC BUS FAIL SHUTDOWN VERSION XXXXXXX OPERATION OF MANUAL BYPASS SWITCH Turn this switch to BYPASS before performing any maintenance on the UPS with the connected load supported Connected equipment will receive filtered AC mains power but will not receive battery power in the event of a blackout SWITCHING UPS TO BYPASS MODE e Press the OFF button e Turn the Manual Bypass Switch clockwise from NORMAL to BYPASS e Turn the AC Input Circuit Breaker OFF e Remove all battery fuses in all Battery Modules connected to the Power Module SWITCHING UPS TO NORMAL MODE e Replace all battery fuses in all Battery Modules connected to the Power Module e Turn the AC Input Circuit Breaker ON e Turn the Manual Bypass Switch counterclockwise from BYPASS back to NORMAL e Press the ON button Communications RS 232 INTERFACE This female DB9 port connects your UPS via an RS 232 cable to a workstation or server equipped with Tripp Lite software The port uses RS 232 communications to report UPS status and power conditions Using this p
11. Y Seller warrants this product if used in accordance with all applicable instructions to be free from original defects in material and workmanship for a period of 2 years except U S Canada and Mexico 1 year from the date of initial purchase If the product should prove defective in material or workmanship within that period Seller will repair or replace the prod uct in its sole discretion Service under this Warranty includes parts and Tripp Lite service center labor Onsite service plans are available from Tripp Lite through authorized service partners in most areas Contact Tripp Lite Customer Service at 773 869 1234 for details International customers should contact Tripp Lite support at intlservice tripplite com THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ALL IMPLIED WAR RANTIES INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This Warranty gives you specific legal
12. as returned to nominal Bypass Voltage Condition LCD Display Message gt 15 Higher than Nominal BYPASS HI NO O P gt 20 Lower than Nominal BYPASS LO NO O P Was Too High Now Nominal BYPASS WAS HI Was Too Low Now Nominal BYPASS WAS LO INVERTER ON WARNINGS When the inverter is ON the LCD Display may show any one of the following warnings Condition LCD Display Message UPS Output Overload OVERLOAD 110 UPS Charger Failure CHARGER FAILURE Abnormal Input Frequency FREQUENCY ERROR Abnormal Input Phase PHASE ABNORMAL Battery is Depleting ON BATTERY Battery Charge is Nearly Depleted BATTERY LOW Since the UPS System can only provide battery backup only for as long as the batteries remain charged these warnings should be acted on immediately Operation Special Conditions iontinuea OPERATION UNDER SHUTDOWN Your UPS will shut down and the LCD will display a message if it detects one of the following conditions Note For all conditions the Input Output and Bypass LEDs will be illuminated Condition LCD Display Message Condition LCD Display Message Overload Shutdown ON BYPASS R S T Inverter Output Failure ON BYPASS OVERLOAD 150 R OUTPUT FAIL SHUTDOWN SHUTDOWN VERSION XXXXXXX VERSION XXXXXXX UPS Output Short Circuit ON BYPASS Low Battery BYPS OFF NO O P SHORT CIRCUIT LOW BATTERY SHUTDOWN SHU
13. cured by connector clamps Tighten connections with a torque of not less than 35 inch pounds Observe the appropriate cable connection regulations e g National Electrical Code NEC in the U S at all times Using cables of improper size may damage your equipment and cause fire hazards Output Input I I O O O OD O O O N2 T2 S2 R2 G G Ni Ri S T NOTE when shipped from the factory bypass input and main input wires are connected UPS BATTERY MODULE HARDWIRE CONNECTION In addition to the instructions listed below follow all warnings found in the Safety section prior to connection WARNING Before attempting to connect the UPS Power Module to the UPS Battery Module qualified personnel must remove all fuses from all UPS Battery Modules CAUTION Make certain that your UPS Power Module and UPS Battery Module use the same DC voltage before connecting them When connecting multiple Battery Modules to a single Power Module the Battery Modules should be approximately the same age Do not connect or disconnect Battery Modules while the Power Module is operating on battery power due to the possibility of dangerous arcing The UPS Power Module will not start without a connection to a charged UPS Battery Module If you plan to store your Battery Module s for an extended period of time fully recharge its batteries every three months by connecting it for at least 12 hours to a UPS Power Module that is connected to AC input WIRING SELECTIO
14. e your equipment and cause fire hazards 18 Grounding Lug connects the Battery Module to earth ground 19 Wheels the wheels are only designed for slight position adjustments within the final installation area they are not designed for mov ing the Battery Module over considerable distances 20 Mounting Brackets allow for permanent mounting if desired User must supply hardware appropriate for mounting surface Installation UPS LOCATION Move your UPS over short distances using its wheels Stabilize the UPS by releasing the stabilizers on each side of the unit NOTE Do not stack the UPS System power module or external battery modules UPS POWER MODULE INPUT AND OUTPUT HARDWIRE CONNECTION In addition to the instructions listed below follow all warnings found in the Safety section prior to connection WIRING SELECTION Choose appropriate cabling rated VW 1 FT 1 or better to connect your UPS Power Module to an AC power supply and your equipment UPS System Model 20kVA 8 AWG 8 mm 30kVA 6 AWG 14 mm Maximum Cable Length 10 m 32 8 ft Wiring Size WIRING CONNECTION Connect your wiring to the input and output terminal blocks located on the lower rear panel of your UPS see figure below CAUTION Qualified personnel should follow all procedures prescribed by N E C and other local codes for hardwiring devices to a utility source Ensure that cables are fitted with cable sleeves and are se
15. els Poe oan o OT STO OToyTo ofofofofo o N eleo gt o o gJ DOO0000 20kVA and 30kVA Power Modules Rear Panel 20kVA amp 30kVA Battery Module Rear Panel Models SU20K3 3INTPM and SU30K3 3INTPM Model BP240V33 1 Manual Bypass Switch This dial is used in one step of putting the UPS in BYPASS mode which must be done before performing any maintenance on the UPS with the connected load supported See Operation Special Conditions for step by step instructions for going into BYPASS While this switch is on BYPASS connected equipment will receive filtered AC mains power but will not receive battery power in the event of a blackout 2 Input Terminal Block Use these terminals to connect your UPS to the AC main power input Unscrew and remove terminal block plate for access 3 Output Terminal Block Use these terminals to connect your UPS to equipment A plate covering the terminal block must be unscrewed and removed for access 4 External Battery Terminal Block Use this to connect a Tripp Lite battery module to the power module Remove the cover for access The power module will not start without a connection to a charged battery module 5 Exhaust Fans These cool and ventilate the inside of the UPS 6 AS 400 Interface Port This female DB9 port connects your UPS to an IBM AS 400 computer interface via the AS 400 Cable includ ed It uses AS 400 communications to report UPS status
16. ia the included software interface The UPS must be in electronic bypass press the OFF Button prior to selecting the UPS s output voltage STEP 1 Load the included software CD on a computer which is connected to the UPS power module through the computer s COMM1 serial port Note the computer must have Windows 98 or above installed in order to run the software STEP 2 In the Utility Directory double click x on the onlineconfig exe executable file STEP 3 Select output voltage either 220 380 230 400 or 240 415 See screen image Value Change Value Output Voltage 240V SS Output Voltage Options ee Pee 2207380 230 400 Close Operation Normal Conditions TURNING THE UPS ON Make sure the UPS is properly installed see Installation section and the Manual Bypass Switch is set to NORMAL Turn the AC Input and Bypass AC Input Circuit Breakers ON If your AC input is providing power normally within your selected range your connected load will energize in Bypass However the UPS s inverter is not yet on Press the front ON button to begin inverter operation If your AC input is not providing power normally you have the option of starting from battery Your battery must be at least partially charged for this operation to succeed Press and hold both the Battery Start switch and the ON button for three seconds to start your UPS in ON BATTERY mode Note that
17. k 100A Output Terminal Block 100A External Battery Terminal Block 100A External Battery Terminal Block 100A Physical Specifications Physical Specifications Power Module Dimensions H x W x D 87 x 38 x 66 cm 34 x 15 x 26 in Power Module Dimensions H x W x D 87 x 38 x 66 cm 34 x 15 x 26 in Power Module Shipping Weight 149 kg 330 Ib Power Module Shipping Weight 149 kg 330 Ib Battery Module Dimensions H x W x D 51x45 x 91 cm 20 x 18 x 36 in Battery Module Dimensions H x W x D 51x 45 x 91 cm 20 x 18 x 36 in Battery Module Shipping Weight 278 kg 611 Ib Battery Module Shipping Weight 278 kg 611 Ib Backup times are expandable with additional Battery Modules sold separately The policy of Tripp Lite is one of continuous improvement Specifications are subject to change without notice This product designed and engineered in the USA Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product TRIPP LITE 1111 W 35th Street
18. ly ON OFF OFF OFF Inverter OFF ON Inactive may be in either state DRY CONTACT INTERFACE This female DB9 contact closure port allows your UPS to send contact closure signals to indicate that it is in battery back up mode and that its batteries are running low The port can also receive a remote shutdown signal DRY CONTACT INTERFACE TABLE UPS Operating Mode Pin 8 3 Pin 1 3 Normal OPEN OPEN Back Up CLOSE x Low Battery CLOSE CLOSE Inactive may be in either state Pin assignment LOW BATTERY I min 23 3mA O t no SIGNAL FROM COMPUTER MAXIMUM CAPACITY OF DRY CONTACT AC 250V 3A DC 30V 3A REMOTE SHUTDOWN SIGNAL FROM EXTERNAL Communications continea REMOTE EMERGENCY POWER OFF EPO This optional feature is only for those applications which require connection to a facility s Emergency Power Off EPO circuit When the power module is connected to this circuit it enables emergency shutdown of the output Using the included cable connect the power mod ule s EPO port to a user supplied remote switch The pin assignments for the EPO port are shown in the following diagram Note if there is a short between pins 2 and 3 2 and 5 4 and 5 or 3 and 4 the UPS system will power off Pin assignment PIN 1 12V Service Warranty LIMITED WARRANT
19. ort Tripp Lite software can monitor and manage network power automatically save open files and shut down equipment during a blackout Contact Tripp Lite Customer Support at 773 869 1234 for information on available SNMP network management and connectivity software and products RS 232 signals and operations include load level battery status battery level operation mode AC input voltage AC output voltage AC input frequency temperature inside unit set shut down delay time enable disable alarm and remote shutdown Hardware Baud Rate 2400 BPS Data Length 8 bits Stop Bit 1 bit Parity NONE AS 400 INTERFACE This female DB9 port connects your UPS to an IBM AS 400 computer via the included AS 400 cable The port uses AS 400 communications to report UPS status It can be used to allow an LOW BATTERY AS 400 to automatically save open files and shut down its operat ing system during a blackout AS 400 protocol includes operation Pin 2 Pin 3 Pin 5 Pin assignment TXD Transmit Data RXD Receive Data GND Signal Ground on inverter operation on AC power supply operation on battery ae and low battery alarm Pin assignment DIRECT MAINS SUPPLY Pin 5 Common Pin 6 Operation on AC power supply Pin 7 Low battery alarm INVERTER Pin 8 Operation on inverter Pin 9 Operation on battery AS 400 INTERFACE TABLE Pin 6 5 Pin 7 5 Pin 8 5 Pin 9 5 Battery OFF ON ON Low Battery OFF ON ON ON Direct Mains Supp
20. ridge the battery terminals with any object Disconnect the charging source prior to connecting or disconnecting battery terminals Determine if the batteries are inadvertently grounded If inadvertently grounded remove the source of the ground Contact with any part of a grounded battery can result in electrical shock The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance Do not dispose of the batteries in a fire The UPS batteries are recyclable Refer to local codes for disposal requirements Connect only Tripp Lite battery modules to your UPS s external battery hardware terminals Do not operate your UPS without batteries Fuses should be replaced only by factory authorized personnel Blown fuses should be replaced only with fuses of the same number and type Potentially lethal voltages exist within this unit as long as the battery supply is connected Service and repair should be done only by trained personnel During any service work the UPS should be turned off or put into manual bypass and fuses removed from all connected battery modules Do not connect or disconnect the battery modules while the UPS is operating from the battery supply or when the unit is not in bypass mode Control Panel There are two separate UPS system modules a power module and a battery module Familiarize yourself with the location and function of the features on each module before installing and opera
21. some electronic equipment may draw more amps during startup when starting from battery consider reducing the initial load on the UPS The UPS will perform a brief self test and show the results on the LCD Display See Self Test section for display sequence After a successful self test the UPS will provide AC power from the inverter to your load TURNING THE UPS OFF e Press the front OFF button Your load will still be energized The inverter is now off but your UPS is not fully deactivated The LCD Display will show ON BYPASS e Turn the AC Input and Bypass AC Input Circuit Breakers OFF Your load will no longer be energized and the LCD display will be dark EA Operation Normal Conditions ontinueo SELF TESTING When you turn the UPS ON it will perform a brief self test See charts below for display sequences Display sequence when AC input power is present Display sequence when AC input power is absent SELF TESTING possible only with the Battery Start Switch RECTIFIER OK SELF TESTING CHARGER OK BATTERY OK BATTERY OK DC TO DC OK DC TO DC OK INVERTER TEST INVERTER TEST LCD DISPLAY SELECT BUTTON Momentarily press the SELECT button on the front panel to browse through different power readings on the LCD Display BYPASS _ OUTPUT R XXXV _R XXX XV S XXXV _ S XXX XV T XXXV T XXX XV 1 Press SELECT Button Bypass amp Output Voltage
22. t with AC power An alarm will sound which can be cancelled by simultaneously pressing and holding the ENTER and SELECT Buttons for a 4 second The alarm will be cancelled but the LED will remain illuminated 10 DC AC Inverter LED This green light will illuminate constantly to indicate the UPS s DC AC inverter is activated 11 O P Output LED This green light will illuminate constantly to indicate your UPS is supplying AC power to connected equipment 12 EMERGENCY POWER OFF Button This button turns the UPS output OFF and disables Bypass output After pressing the but ton it will remain down until reset To reset the UPS system and restore output press the Emergency Power OFF Button until it pops back up If the Input Breakers are OFF turn them ON Press the OFF Button The UPS will re start if AC line power is present 13 LCD Display This backlit dot matrix display indicates a wide range of UPS operating conditions and diagnostic data It will illumi nate after you have properly completed installation and start up and after the ON Button is depressed Note the LCD Display s backlighting will turn off 10 minutes after any of the following front panel buttons have been depressed SELECT ENTER OFF or ON To turn on the LCD Display s backlighting momentarily depress any of the following front panel buttons SELECT ENTER OFF or ON Rear Pan
23. ting your UPS system The power module is the only module which includes front panel features FRONT PANEL EMERGENCY POWER OFF 1 ON Button This button turns the UPS System s inverter ON 2 OFF Button This button turns the UPS System s inverter OFF 3 ENTER Button This button changes or selects the variables shown on the LCD Display Simultaneously press the ENTER Button and the SELECT Button and hold for a 4 second to mute audible alarm 4 SELECT Button This button allows you to browse through different power readings on the LCD Display by momentarily pressing the button Simultaneously press the ENTER Button and the SELECT Button and hold for a 1 4 second to mute audible alarm 5 I P Input LED This green light will illuminate constantly to indicate an AC input supply is present 6 BYPASS I P Bypass Input LED This green light will illuminate to indicate an AC input supply is present at bypass input 7 BYPASS LED This green light will illuminate when the UPS is providing filtered mains power without engaging its converter or inverter Connected equipment will not receive battery power in the event of a blackout 8 AC DC Converter LED This green light will illuminate constantly to indicate the UPS s AC DC converter is activated 9 BATTERY LED This red light will flash when the UPS is discharging the battery to provide connected equipmen
24. urrent Input Current Per Phase On Line 30A 29A 28A Per Phase On Line 45A 43A 41A Inrush Current lt 300A Inrush Current lt 300A Power Factor Full Load gt 0 95 Power Factor Full Load gt 0 95 Efficiency Full Load On Line gt 90 Efficiency Full Load On Line _ gt 90 Circuit Breaker 50A 3p Circuit Breaker 63A 3p Input Bypass Circuit Breaker _ 550A 3p Input Bypass Circuit Breaker 63A 3p Output Output VA 20000 VA 30000 Watts Power Factor 0 8 16000 Watts Power Factor 0 8 24000 Waveform On Line Sinewave Waveform On Line Sinewave Waveform On Battery Sinewave Waveform On Battery Sinewave Output Voltage RMS User selectable 220 380 230 400 240 415V AC 39 4 wire plus ground wye Output Voltage RMS User selectable 220 380 230 400 240 415V AC 39 4 wire plus ground wye Output Frequency 50 60 Hz auto selectable 0 1 Hz on battery Output Frequency 50 60 Hz auto selectable 0 1 Hz on battery Voltage Regulation 2 Voltage Regulation 2 Max Harmonic Distortion Non Linear Full Load lt 3 Max Harmonic Distortion Non Linear Full Load lt 3 Overload Capabilities lt 102 continuous 102 125 1 min 125 150 30 sec 2150 2 sec Overload Capabilities lt 102 continuous 102 125 1 min 125 150 30 sec 2150 2 sec Short Circuit Capability 2