Home
TRENDnet TPL307E2K Network Hardware User Manual
Contents
1. 23 Chapter 6 Specifications r 25 Chapter 1 Product Overview The TPL 307E TPL 307E2K is an excellent solution that can be used to extend your network using vour home or small office electrical wiring In a home or small office building use the 200Mbps Powerline AV Adapter with Bonus Outlet to link multiple locations without the need to run long Ethernet cables Combined with a single broadband DSL Cable Internet connection everv room with electrical power outlets can provide easy access to your high speed Internet connection With HomePlug AV speeds of up to 200Mbps this easy to setup solution can provide fast streaming HD movies online multiplayer games and other data intensive applications for today s HD Entertainment Center demand Each TPL 307E 200Mbps Powerline AV Adapter with Bonus Outlet allows you to connect one network enabled device to a powerline network via Ethernet In operation the 200Mbps Powerline AV Adapter with Bonus Outlet is completely transparent and simply passes data between the Ethernet port and the powerline network Any Ethernet enabled device may be connected to the 10 100Mbps Auto MDIX Ethernet port 1 1 Powerline Network Solution Add high speed Internet access to any room in your home with this 200Mbps act Powerline AV Adapter You can stream HD movies and music play online multi
2. TRENDNET User s Guide TPL 307E TPL 307E2K 1 01 Table of Contents Chapter 1 Product Overview a 3 1 J Powerline Network S IBLIorku uu u y u u uu u u uuu a uu au ri 3 1 2 Package Contents ai rag dei ti ta te ai eta dia 4 1 3 System Re iljirements uu uu u uu uu uuu uusssasasssasasssunasssssapapasawaspussassasas 4 1 4 Devi Ce Ss DO uuu aa ien tadatta 5 J SE Siero u acts u a unn 5 1 6 Ethernet Port Buttons cccccccscsccsccsceccsccscescetesccscstesccscatsecescetsesencs 7 Chapter 2 Product Installation 8 2 1 Wi Ciel WINS el A Ol x un eosananeitesanetia eee 9 2 2 Securing your Powerline Netwolrk 10 2 3 Changing the Network Name Security Key using the Sync Button 11 2 4 Adding the Powerline Adapter to an Existing Powerline Network 12 Chapter 3 Overlapping Powerline Networks 13 3 1 Move Powerline Adapters between different Powerline Networks 14 Chapter 4 Powerline Configuration Utility 15 Al l SOPEW ale MSt alll AU O Men acctcsvadcannonsdactaaveaisbawandesaeraadssunenadschanwucsssawardcdarnn sites 15 AD Usine Ime Utily casa i a uu mu a a mus s asss 20 Chapter 5 Troubleshooting
3. TRENDnet Powerline Utility has been successfully installed Chek Close ta exit Cancel 4 2 Using the Utilitv Double click the desktop icon to open the Powerline Configuration Utilitv application Wiis TRENDnet Powerline Utility e Privacy Tab Main Privacy Lecco l l Change the Local Lievicels on your computer Network Device Type MAL Address Connected to HomePlug AW 6x00 Device Name Security Key Local HomePlug AW 6x00 D 00 30 47 15 83 02 Device i The closest Upgrade Firmware powerline 2 Powerline Devices detected Network Type Private Autoscan On adapter s Rate Mbps MAC Address that connects Device b T 00 70 28 64 1220 your computer to the electrical system bs Device 5 LCHH HDE vl T TMM 184 00 00 90 47 75 82 00 Remote Devices amp TRENDNET Powerline Rename Enter Password adapters that are connected to Closes the the selected utility Local Device application across the Enter the Add a Scans for electrical Device Remote Remote system Password Device that Devices that DPW for the was not were not Device selected detected detected Remote Device e To apply changes to Remote Devices through the Powerline Configuration Utility you must enter the Device Password DPW for each Remote Device located on the Device Label The 16 character password should be all alphabetic characters with no numbers e If you have not already done so please w
4. TPL 310AP TPL 305E TPL 306E TPL 401E TPL 402E or another TPL 307E The TPL 307E2K already includes two TPL 307E adapters Powerline Configuration Utility System Requirements Supported Operating Systems CPU Windows 7 32 64 bit 1GHz or above 1GB RAM or above Windows Vista 32 64 bit 800MHz or above 512MB RAM or above Windows XP 32 64 bit 300MHz or above 256MB RAM or above 1 4 Device Label The device label can be located on the back of the device where the power prong is found TRENDNET Product Model MODEL NO Device Serial Number Eq F B gt 3 N Ili Device MAC Address AC Device Password DPW gt DP W VARS ECHE SAGA OWED Product Hardware Version H 0R Product Firmware Version w This device complies with Part 15 of FCC Rules Made in China 1 5 LEDs The LED panel located on the front of the device consists of the status LEDs Power PWR Powerline PL and Ethernet Link Act ETH TRENDNET B lt PKower PWR TPL 3O7E DRIA g t Powerline PL PL m Ethernet ETH l e v lt LED Color Device powered On PWR Power N A Device powered Off PL Powerline Connected Connection Quality is Best Powerline Svncing or Powerline Data Transmitting Receiving Connection Blinking Qualitv is Best Note LED color indicates the strength and qualitv of the powerline connection through the electrical
5. The Powerline Configuration Utility requires the use of the WinPcap application If this prompt does not appear you may already have the WinPcap application installed If so please skip over to Step 9 r U l WinPcap 4 1 1 Installer JIM IP Welcome to the WinPcap 4 1 1 Installation Wizard gt cap This product is brought to you by CACE TECHNOLOGIES Packet Capturing and Network Analysis Solutions Mullsaft Install System v2 45 wx Welcome to the WinPcap 4 1 1 Setup Wizard This Wizard will guide you through the entire WinPcap installation For more information or support please visit the WinPcap home page http www winpcap org 6 Inthe License Agreement window click Agree License Agreement Jin Peap Please review the license terms before installing WinPcap 4 1 1 Press Page Down to see the rest of the agreement Copyright c 1999 2005 NetGroup Politecnico di Torino Italy Copyright c 2005 2009 CACE Technologies Davis California All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of condi tions and the following disclaimer in the documentation and or othe
6. svstem Powerline Connected Connection Qualitv is Better Powerline Data Transmitting Receiving Connection Qualitv is Blinki sab Better Powerline Connected Connection Quality is Good Powerline Data Transmitting Receiving Connection Quality is Good Blinking Powerline is not synced or connected 10 20 Mbps or 100 200Mbps Half Full Duplex Connected Blinkin 10 20Mbps or 100 200Mbps Half Full Duplex Data 8 Transmitting Receiving Port Disconnected No Ethernet Link ETH Ethernet Connection Note The following factors may affect the powerline network s connection quality e Noise Generated by appliances that are connected to your electrical system through power outlets that have high power consumption requirements e g Microwaves ovens blow dryer iron dishwasher etc The quality of your household electrical wiring may also cause additional noise on your electrical system e Distance Long lengths of electrical wiring through your electrical system between connected powerline adapters 1 6 Ethernet Port Buttons There is one RJ 45 10 100Mbps Auto MDIX Ethernet port Reset Button and Sync Button located at the bottom of the device Ethernet Port sync Button Reset Button Initiate Sync Connection and generate random network name key on first adapter PWR LED will start blinking Match network name key on secondary or additional adapter and Push Hold for 2 connect to first adapter PW
7. This tool allows for easv management for multiple powerline adapters in vour network Note 1 Before installing and using the utilitv write down the 16 digit Device Password DPW and MAC Address of each TPL 307E powerline adapter as this will be required to applv changes to remote devices discovered in the utilitv This is located on the Device Label please refer to Section 1 4 2 Before installing and using the utilitv make sure vour computer in which vou are installing the utilitv is connected to vour network and vour TPL 307E adapters are also connected to vour network 3 Make sure all of the TPL 307E powerline adapters are already connected to each other using the procedures in Chapter 2 Product Installation 4 The utility is only compatible with Windows operating systems For details please refer to Section 1 3 4 1 Software Installation 1 Insert the included CD ROM into your computer s CD ROM drive 2 At the CD Autorun Prompt window click Run Autorun exe Note If the Autorun prompt does not appear automatically open the CD contents and double click Autorun exe 3 At the CD ROM menu window click Install Utility TRENDnet Install Utility User s Guide Product Registration 200Mbps Powerline AV Adapter with Bonus Outlet TPL 307E 200Mbps Powerline AV Adapter Kit with Bonus Outlet TPL 307E2K Copyright 2011 THEND net All Rights Reserved 4 Atthe WinPcap installer window click Next Note
8. each other and the third TPL 307E Additional powerline adapter is currentiv disconnected 1 Push and hold the Svnc button on the additional TPL 307E powerline adapter for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current network name securitv kev assigned to the additional TPL 307E powerline adapter 2 Push and hold the Svnc button on one of the two TPL 307E powerline adapters that are currently connected to each other for 2 seconds and release it The PWR LED will start blinking 3 Within 2 minutes 120 sec push and hold the Svnc button on the additional TPL 307E for 2 seconds and release it The PWR LED will start blinking This will establish connectivitv between the three powerline adapters bv assigning the additional TPL 307E powerline adapter s network name security key to match the network name security key of the TPL 307E powerline adapters that are currently connected 4 To verify connectivity between the three powerline adapters make sure that the PL LED on each powerline adapter is on solid Green Amber Red Please refer to the LED section 1 5 for details on the LED indicator Chapter 3 Overlapping Powerline Networks It is possible to create multiple powerline networks on the same electrical system separated and grouped by different network names securitv keys The powerline networks will work and communicate independentiv of each other which can provide securitv be
9. oz Per Unit Weight 175 g 6 2 oz Power Source 100 240V AC 50 60Hz Consumption Active mode 3 Watts max Standby mode 0 6 Watts max Temperature Operating 0 40 C 32 104 F Storage 20 70 C 4 158 F Humidity Max 90 non condensing Certifications CE FCC HomePlug AV Maximum of 6 adapters nodes for streaming video across your network 200Mbps is the maximum theoretical Powerline data rate Actual throughput will vary depending on environ ment Networked Powerline devices need to be plugged into power outlets that are on the same electrical system GECI outlets and AFCI circuit breakers may degrade Powerline network signals Limited Warrantv TRENDnet warrants its products against defects in material and workmanship under normal use and service for the following lengths of time from the date of purchase TPL 307E TPL 307E2K 3 Vears Warrantv AC DC Power Adapter Cooling Fan and Power Supply carry 1 year warranty If a product does not operate as warranted during the applicable warrantv period TRENDnet shall reserve the right at its expense to repair or replace the defective product or part and deliver an equivalent product or part to the customer The repair replacement unit s warranty continues from the original date of purchase All products that are replaced become the propertv of TRENDnet Replacement products mav be new or reconditioned TRENDnet does no
10. 184 00 00 30 47 15 82 DD TRENDNET 5 Repeat steps 1 4 for any remaining Remote Devices 6 Once all of the Device Passwords DPW are entered into the utility changes can be applied to the Remote Devices using the utility Change the Network Name Security Key for multiple adapters using the utility 1 Click the Privacv tab 2 Under Private Network Name enter the desired network name securitv kev and click Set All Devices 3 Atthe Network Name Setting prompt window click OK a Setting the metwork name on the dewices whose password has been W entered This may take few seconds Click on Ok button The current network name security key assignment of the powerline adapter s Note If you had previously used the Sync button procedure in generating a random network name security key This will display Unknown Networkname Main Privacy Diagnostics About Use this screen ta create a Private Network that provides you with estra security Frivate Network Mame HomePlug 0R Use Default Public Network Do not share the network name with others you do not want ta be part of this network After setting the name above choose how it will be applied below Place On This Network Only the device attached to this computer the Local Device TANTI Isolates this computer Horn others et Local Vevice Oniy OF ALL devices whose Password has been entered They communicate together
11. FORMANCE FAILURE OR INTERRUPTION OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT TRENDNET S OPTION THIS DISCLAIMER OF LIABILITV FOR DAMAGES WILL NOT BE AFFECTED IF ANV REMEDV PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE Governing Law This Limited Warrantv shall be governed by the laws of the state of California Some TRENDnet products include software code written by third party developers These codes are subject to the GNU General Public License GPL or GNU Lesser General Public License LGPL Go to http www trendnet com gpl or http www trendnet com Download section and look for the desired TRENDnet product to access to the GPL Code or LGPL Code These codes are distributed WITHOUT WARRANTY and are subject to the copyrights of the developers TRENDnet does not provide technical support for these codes Please go to http www gnu org licenses gpl txt or http www gnu org licenses Igpl txt for specific terms of each license MU 76 ub oe gt o eee ea KA ob hea A Q Q Doppa oeoo Gad o 6 f 8 f Wa a e G gt a eo200 kg f lt Dnia 1 Z ALALLE JI YT YT T TZ o2 6 9 t fa B ga te ew peoo AALE v D ALT TTILE eceoceso o o 9 G O w K O00 gt i A A 7 oe og II W EN 7 60 C6000 amp eo amp Copyright 2011 All Rights Re
12. IEEE 1901 HomePlug AV IEEE 802 3 IEEE 802 3x IEEE 802 3u e 1x10 100Mbps Auto MDIX RJ 45 Port e 1x electrical power socket with noise filtering 12A max load e Power prong Interface o A North America Type B NEMA 5 15 o EU Euro Type C CEE 7 16 o FR French Type E CEE 7 5 o UK United Kingdom Type G BS 1363 Frequency Band 2728 MHz Modulation OFDM Symbol modulation on link synchronization 1024 256 64 8 QAM QPSK BPSK ROBO carrier Protocols TDMA and CSMA CA Speed Powerline up to 200Mbps Ethernet up to 200Mbps with Full Duplex mode Utility OS Compatibility Windows 7 32 64 bit Vista 32 64 bit XP 32 64 bit Up to 6 max Overlapping Powerline Up to 4 per electrical system Networks Supported Coverage Up to 300 m 984 ft Security 128 Bit AES Advanced Encryption Standard Power PWR Powerline PL with Connection Quality Indication Best Green Better Amber Good Red No connection Off m O Ethernet ETH Connection e Solid e Blinking e Off Svnc Reset A 122 x 55 x 60 mm 4 8 x 2 2 x 2 4 in per unit EU FR 122 x 55 x 78 mm 4 8 x 2 2 x 3 1 in per unit UK 122 x 55 x 72 mm 4 8 x 2 2 x 2 8 in per unit Dimension L x W X H A Total Weight 294 g 10 4 oz Per Unit Weight 147 g 5 2 oz EU Total Weight 336 g 11 8 oz Per Unit Weight 168 g 5 9 oz FR Total Weight 338 g 12 oz Per Unit Weight 169 g 6 0 oz UK Total Weight 350 g 12 4
13. R LED will start blinking sec Note The secondarv or additional powerline adapter s Svnc button must also be pushed within 2 minutes 120 sec of pushing the Svnc button of the first adapter in order to establish connectivitv Push Hold for Erases the network name kev 10 sec All LEDs will turn off and turn back on Reset device to factory defaults All LEDs will turn off and turn back Push Hold for 1 on sec Note Will reset to the factorv default private network name HomePlugAV Chapter 2 Product Installation At factory default settings a pair of TPL 307E 200Mbps Powerline AV adapters with Bonus Outlet or TPL 307E2K can be installed into any room in your home or small office with a wall power outlet without the need for additional software or configuration To create a simple powerline network using a pair TPL 307E powerline adapters simply plug one of your TPL 307E adapters into a wall power outlet in one room and plug the other TPL 307E adapter into an available wall power outlet in another room to establish connectivity between the two rooms In order to share Internet connectivity through your powerline adapters it is ideal to install at least one powerline adapter in the room where your modem and router are located and connect the powerline adapter to one of your router s LAN ports via Ethernet Any additional powerline adapters that are installed and connected in other rooms will then share Internet connectivity thr
14. but are isolated from devices with Get All Devices a different network name Applies changes to Local Device only Note If you choose this option you will disconnect the Local Device from the Remote Devices Applies changes to Local Device and Remote devices Note If you have not entered the DPW for all remote devices you will receive an error and the changes will not be applied to remote devices without a DPW Chapter 5 Troubleshooting Please reference the items below if vou continue to experience difficultv with installing and using your TPL 307E 200Mbps Powerline AV Adapter e Try power cycling the unit by unplugging it from the wall power outlet for 15 seconds and plugging it back in e If the PL LED is red indicating good quality only try plugging the TPL 307E into another available wall power outlet to check if you can obtain better connection quality e Use a pin or paperclip and push and hold the Reset button for 1 second on each TPL 307E powerline adapter All LEDs will turn off and turn back on This will reset the TPL 307E powerline adapters to the default settings network name securitv kev assignment HomePlugAV e The TPL 307E can provide better connectivity and performance when plugged directly into the wall power outlet instead of a power strip or surge protector e Connecting the TPL 307E to a power strip or surge protector may degrade network performance or completely stop networ
15. e e g Game Console Blu rav plaver IP Set Top Box network enabled TV etc is located 4 Connect one end of the Ethernet Cable into the Ethernet port located at the bottom of the second TPL 307E and the other end of the Ethernet cable into the Ethernet port on vour computer or network appliance e g Game Console Blu rav plaver IP Set Top Box network enabled TV etc 5 To verify connectivity between the TPL 307E powerline adapters make sure that the PL LED on each TPL 307E is on solid Green Amber Red Please refer to the LED section 1 5 for details on the LED indicator 6 You have successfully created a basic powerline network between a pair of TPL 307E powerline adapters The computer or network appliance connected to the second powerline adapter via Ethernet can now access the Internet Modem Router ra ee Ethernet Powerline 2 2 Securing your Powerline Network The TPL 307E 200Mbps Powerline AV Adapter with Bonus Outlet has a default network name security key assignment of HomePlugAV When connecting a pair of TPL 307E powerline adapters both powerline adapters will be assigned the default network security key which allows the TPL 307E powerline adapters to establish connectivity through your home or small office s electrical system without the need for additional software or configuration For added security the default network name security key can be modified using the TPL 307E Sync button covered
16. ement window check the radio button Agree and then click Next fg TRENDnet Powerline utility ETT License Agreement Please take a moment to read the license agreement nom IF you accept the terms below click l Agree then Mest Otherwise click Cancel Atheros Communications Inc Software License Agreement PLEASE READ THIS SOFTWARE LICENSE AGREEMENT LICENSE CAREFULLY BEFORE USING THE ATHEROS SOFTWARE BY USING THE ATHEROS SOFTWARE YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS LICENSE IF YOU DO NOT AGREE TO THE TERMS OF THIS LICENSE DO NOT USE THE SOFTWARE IF YOU DO NOT AGREE TO THE TERMS OF THE LICENSE YOU MAY RETURN THE ATHEROS SOFTWARE TO THE PLACE WHERE YOU TAT ee TE TE Te ee a a sma Toe soe I Do Not Agree 11 In the Select Installation Folder window click Next Select Installation Folder The installer will install TRENDnet Powerline Utility to the following folder Ta install in this folder click Next Ta install ta a different folder enter it below or click Browse Folder C Program Files TREND nets TRENDnet Powerline Utility Install TRENDnet Powerline Utility for yourself or for anyone who uses this computer 7 Everyone Just me Contirm Installation The installer iz ready to install TRENDnet Powerline Utility on pour computer Click Next to start the installation 13 At the Installation Complete window click Close Installation Complete
17. in the following section or through the use of the Powerline Configuration Utility in Chapter 4 Note The default network name security key assigned to the TPL 307E is HomePlugAV All powerline adapters in the same powerline network must have the same network name security key in order to establish connectivity If the network name security keys are not the same for all powerline adapters on the same powerline network the adapter will NOT establish connectivity TRENDnet Powerline AV models TPL 303E TPL 304E TPL 305E TPL 310AP TPL 306E TPL 307E TPL 401E TPL 405E and TPL 402E all have the same default network name security key assignment of HomePlugAV 2 3 Changing the Network Name Securitv Kev using the Svnc Button The procedure describes how to create a change the network name securitv kev between a pair of TPL 307E powerline adapters This procedure can also be used to establish connectivitv between two powerline adapters that are currentiv disconnected and change the default network name securitv kev simultaneousiv w s Electrical Wiring Powerline Network Assuming your TPL 307E powerline adapters are already plugged into wall power outlets and either currently connected or disconnected to each other 1 Push and hold the Sync button on one of the TPL 307E powerline adapters for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current network name securitv key assigned t
18. k signals e The TPL 307E is not recommended for use on GFI protected outlets and electrical systems with AFCI circuit breakers as these items may filter out powerline signals e The TPL 307E should not be used in areas with excessive heat e Certain florescent or incandescent lights are noise sources on the electrical and can degrade powerline performance e If your building has more than one circuit breaker box the TPL 307E may not be able to establish connectivity between different circuit breaker boxes In this case connect a TPL 307E powerline adapter to a power outlet located on each of the circuit breaker boxes and then connect an Ethernet cable between the TPL 307E powerline adapters to bridge the two circuits together This will allow the TPL 307E powerline adapters from different circuit breaker boxes connect to each other Power Saving The device will automaticallv reduce power usage when the connected devices via Ethernet are powered off unplugged or inactive for more than 3 minutes Erp EuP Operation Standbv Mode e Disconnect the Ethernet cables from the device Ethernet ports and after 3 minutes the device will enter standbv mode The Power PWR LED will flash everv 15 seconds to indicate that the device is currentiv in standbv mode e Toreturn to active mode reconnect the Ethernet cables to the device Ethernet ports and the device will re enter active mode Chapter 6 Specifications Hardware Standards
19. o the first powerline adapter 2 Push and hold the Sync button on the other TPL 307E powerline adapter for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current network name securitv key assigned to the second powerline adapter 3 Push and hold the Sync button on the first TPL 307E powerline adapter for 2 seconds and release it The PWR LED will start blinking This will initiate sync connection and generate a random network name securitv key assignment to the first adapter 4 Within 2 minutes 120 sec push and hold the Sync button on the second TPL 307E powerline adapter for 2 seconds and release it The PWR LED will start blinking This will establish connectivity between the two powerline adapters by assigning the second powerline adapter s network name security key to match the network name securitv key of the first powerline adapter 5 To verifv connectivitv between the two powerline adapters make sure that the PL LED on each powerline adapter is on solid Green Amber Red Please refer to the LED section 1 5 for details on the LED indicator 2 4 Adding the Powerline Adapter to an Existing Powerline Network The procedure describes how to add the TPL 307E 200Mbps Powerline AV Adapter with Bonus Outlet to an existing powerline network Bridge C Additional mem Flectrical Wiring Powerline Network Assuming the two TPL 307E powerline adapters are currentiv connected to
20. ough your router Once the powerline adapters are connected to each other through the electrical system any additional devices such as computers or network appliances e g Game Console Blu ray player IP Set Top Box network enabled TV etc connected to any of your powerline adapters via Ethernet can then communicate to each other as well as share Internet connectivity through your router 2 1 Initial Installation The procedure describes how to create a basic powerline network between a pair of TPL 307E powerline adapters and share Internet connection through a router to a computer or network appliance in another room Assuming vour router is alreadv installed and configured for Internet connectivitv and the TPL 307E powerline adapters are at factorv default settings 1 Plug one of the TPL 307E powerline adapters into an available wall power outlet in the room where vour router is located Warning Do not plug the powerline adapter into a power strip that has surge protection Doing so will degrade power line performance For best performance plug all powerline adapters directly into a wall power outlet 2 Connect one end of the Ethernet Cable into the Ethernet port located at the bottom of the TPL 307E and connect the other end of the Ethernet cable into one of the router s LAN ports 3 Plug the second TPL 307E powerline adapter into an available wall power outlet in another room where vour computer or network applianc
21. player games and much more Note This TPL 307E 200Mbps Powerline AV Adapter with Bonus Outlet needs to pair with at least one other IEEE 1901 or HomePlug AV compatible powerline device e g TRENDnet Powerline AV products TPL 305E TPL 303E TPL 304E TPL 310AP TPL 306E TPL 401E TPL 402E TPL 405E or another TPL 307E The TPL 307E2K 200Mbps Powerline AV Adapter Kit with Bonus Outlet already includes two TPL 307E adapters therefore there is no requirement for an additional powerline adapter 1 2 Package Contents The product package should contain the following items TPL 307E 200Mbps Powerline AV Adapter with Bonus Outlet TPL 307E Multi Language Quick Installation Guide CD ROM Utility amp User s Guide Network Cable 1 5 m 5 ft TPL 307E2K 200Mbps Powerline AV Adapter Kit with Bonus Outlet 2 X IPL 307E Multi Language Quick Installation Guide CD ROM Utilitv amp User s Guide 2 x network cables 1 5 m 5 ft If any of the parts are incorrect missing or damaged contact your dealer Keep the carton including the original packaging materials in case vou need to return the Powerline adapter for repair 1 3 Svstem Requirements CD ROM drive A Desktop or Laptop PC with Network Adapter Installed Existing 10 100Mbps wired network when TPL 307E is used as a bridge device Additional HomePlug AV or IEEE 1901 compliant powerline adapter Note Requirement for TPL 307E only e g TRENDnet TPL 303E TPL 304E
22. r materials If you accept the terms of the agreement dick I Agree to continue You must accept the agreement to install WinPcap 4 1 1 Mullsoft Install System v2 45 7 In the Install Options window click Install Gw iss Installation options Iin cap B review the following options before installing WinPcap Operating system detected on registry Windows 7 x86 True operating system kernel dll Windows 7 x86 npptools dil present on the system false netnm inf present on the system false nmnt sys present on the system false Nullsoft Install System v2 45 8 At the Setup Wizard Completion window click Finish Completing the WinPcap 4 1 1 Setup Wizard WinPcap 4 1 1 has been installed on your computer Click Finish to dose this wizard 9 The TRENDnet Powerline Configuration Utilitv installation window will appear automaticallv At the Setup Wizard window click Next jal TRENDnet Powerline Utility asa ee Welcome to the IRENDnet Powerline Utility Setup Wizard The installer will guide vou through the steps required to install TRENDnet Powerline Utility on your computer WARNING This computer program i protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it map result in severe civil or criminal penalties and will be prosecuted to the masimum extent possible under the law 10 In the License Agre
23. re currentiv connect together to form one powerline network and Adapters D and E form another powerline network Adapter B will be disconnected from Adapters A and C and connected to Adapters D and E 1 Push and hold the Svnc button on Adapter B for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current network name securitv kev assigned to Adapter B and disconnect from Adapters A and C 2 Push and hold the Sync button on Adapter D for 2 seconds and release it The PWR LED will start blinking 3 Within 2 minutes 120 sec push and hold the Sync button on Adapter B for 2 seconds and release it The PWR LED will start blinking This will establish connectivity between Adapters B D and E by assigning Adapter B s network name security key to match the network name security key of Adapters D and E 4 To verify connectivity between the powerline adapters make sure that the PL LED on each powerline adapter is on solid Green Amber Red Please refer to the LED section 1 5 for details on the LED indicator Chapter 4 Powerline Configuration Utilitv The Powerline Configuration Utility is an additional tool that allows you to centrally manage the powerline adapters that are connected to vour network Instead of using a randomiv generated kev with the Svnc button the utilitv allows vou to manuallv configure the network name securitv kev for a single powerline adapter or multiple adapters simultaneousiv
24. rite down the 16 digit Device Password DPW and corresponding MAC Address of each TPL 307E powerline adapter as this will be used to input into the utility This is located on the Device Label please refer to Section 1 4 Enter the 16 digit Device Password DPW for each Remote Device in the utility 1 Click one of the Remote Devices in the list 2 Click Enter Password 3 Tvpein the Device Password according to the corresponding MAC address Then click OK 7 Set Device Password Device Device 5 00 90 47 15 82 DD Password LCHN ZHDE VGTE SJIR The Password typically appears as a number and letter code in groups of four separated by dashes ie XK8Y GH26 BR1K LZSA It is found on the device or packaging Cancel A If successful the Remote Device will have the Device Password listed next to the device under Password Note If the incorrect Device Password is entered you will receive an error message Click Enter Password and try entering the password again TRENDnet Powerline Utility A Man Privacy Diagnostics About Local Device s on pour computer Device Type MAL Address Connected to HomePlug AY 6x00 Device e HomePlug AY 6x00 D 00 30 47 15 83 02 Connect Upgrade Firmware 2 Powerline Devices detected Network Type Private Autoscan On Device Name Password Quality Rate Mbps MAC Address Device 6 l 6 00 00 70 28 64 12 2D Device 5 LCHN ZHDE VGT lll
25. served Q D re O amp v gt 6 XI _ TTTTTTTT kal Lat A A L 2 K 14 RARE ES o e A AM ee a c 4 a a of fu s lt l gt gt 2 y nee oes XY A Oo gt ALA f Q AAE De t 2 ri e n TELLI ee a g gt amp 4 amp p gt fh Te 4 gt a ogo f w YV PRA 6 r 4 d EELEE f y ta e f X i f o e gt a Qo t TRENDnet hE i Lit i RRL i 1 L fi ee TRENDNET Ba GE E E D o h e o o a RRR LAL ALAA SL A SSeS eCO0OC6C0C60 060 OEE TEKITA A ssoeeeoeee ETETETT o Oo I 1 1 1 j J 1 T 1 7 22 Z L L 1 2 1 1 Z PALI LIL TIN Seeoseeee eer PRE RE RE RE SE DS 9 0 0 0 00009 00000 coococeoceoeoeeeoge PERRIER Y YY FF FF EN SRRERARRRREAR ITE ER X L EERE TLL LET 2 Osta FEIL Z 1 11 1 1 oer AAA LEAD eeeoce Ceooee ce 0066686 00 a B u 3 o D e A ALLL l 1 seosesee seeceececee e LAL TEL EE a
26. t issue refunds or credit Please contact the point of purchase for their return policies TRENDnet shall not be responsible for anv software firmware information or memorv data of customer con tained in stored on or integrated with anv products returned to TRENDnet pursuant to anv warrantv There are no user serviceable parts inside the product Do not remove or attempt to service the product by any unauthorized service center This warrantv is voided if i the product has been modified or repaired bv anv unau thorized service center ii the product was subject to accident abuse or improper use iii the product was subject to conditions more severe than those specified in the manual Warrantv service mav be obtained bv contacting TRENDnet within the applicable warrantv period and providing a copy of the dated proof of the purchase Upon proper submission of required documentation a Return Material Authorization RMA number will be issued An RMA number is required in order to initiate warrantv service sup port for all TRENDnet products Products that are sent to TRENDnet for RMA service must have the RMA number marked on the outside of return packages and sent to TRENDnet prepaid insured and packaged appropriatelv for safe shipment Customers shipping from outside of the USA and Canada are responsible for return shipping fees Customers shipping from outside of the USA are responsible for custom charges including but not limited to du t
27. tween different groups of powerline adapters For example if vou have five powerline adapters Adapter A Adapter B Adapter C Adapter D Adapter E vou can group Adapters A B and C together on one powerline network and group Adapters D and E on a different powerline network Each group will use a different network name securitv kev Note It is recommended that onlv a maximum of up to 4 powerline networks can be created per electrical svstem Anv additional powerline networks above the recommended result in significant degradation in powerline performance 3 1 Move Powerline Adapters between different Powerline Networks Use the procedures in Chapter 2 Product Installation to connect one group of adapters then vou can carrv out the procedures on another group of adapters to create multiple overlapping powerline networks This procedure describes how to disconnect a powerline adapter from one powerline network and connect the adapter to a different powerline network Disconnect Adapter B from Network ABC Connect Adapter B to Network DE Mil A Adapter A Adapter B Adapter D LI gt it FF serine aan I i e A ELITEI HHH EH E a s eos U lt tr L TT mr 1 4 U mr L if iil Adapter C _ L p l ME Assuming all powerline adapters are TPL 307E adapters and for reference in the diagram and this procedure the adapters will be labeled Adapter A B C D and E Adapters A B and C a
28. v tax and other fees WARRANTIES EXCLUSIVE IF THE TRENDNET PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE THE CUSTOMER S SOLE REMEDY SHALL BE AT TRENDNET S OPTION REPAIR OR REPLACE THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TRENDNET NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF TRENDNET S PRODUCTS TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW TRENDNET ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATE OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PER
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - 1E - A&A Hydraulic for the best in Mityvac parts. manual de instrucciones / andador sunny mod. 7174 Installazione driver e software Karcher K 5.70 M User's Manual Whirlpool MH7lOOXY User's Manual Wenn Sie - Haibrain Manual - Daewoo Electronics México les partenaires Benutzerhandbuch PC - GPS-Mate Black & Decker DLX900 Use & Care Manual Copyright © All rights reserved.